Compact TV Analyzer
Specifications
year
CONTENTS
Definitions ....................................................................................................................................................................... 3
Specifications .................................................................................................................................................................. 4
TV analyzer ...................................................................................................................................................................... 4
Frequency ......................................................................................................................................................................................... 4
Level.................................................................................................................................................................................................. 4
MPEG decoder board (R&S®ETC-B280 option, requires at least one digital TV standard R&S®ETC-K140, R&S®ETC-K160 or
R&S®ETC-K240).............................................................................................................................................................................. 13
Sweep time...................................................................................................................................................................................... 14
Bandwidths ...................................................................................................................................................................................... 14
Level................................................................................................................................................................................................ 15
Definitions
General
Product data applies under the following conditions:
Uncertainties
Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been
calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account
environmental conditions, aging, wear and tear.
Device settings and GUI parameters are designated with the format “parameter: value”.
Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz.
Specifications
TV analyzer
Frequency
Frequency range model .04 4.5 MHz to 3.6 GHz
model .08 4.5 MHz to 8 GHz
Resolution 1 Hz
Reference frequency, internal
Aging per year 1 × 10–6
Temperature drift 0 °C to +30 °C 1 × 10–6
+30 °C to +50 °C 3 × 10–6
Achievable initial calibration accuracy 5 × 10–7
Total reference uncertainty 0 °C to +30 °C (time since last adjustment × aging rate)
+ temperature drift + calibration accuracy
Reference frequency, with R&S®HA-Z240 option
Frequency uncertainty GPS on, ≥ 1 minute after satellite lock 2.5 × 10–8
up to 30 minutes after losing satellite lock 5 × 10–8
Spectral purity of SSB phase noise RF = 500 MHz
Carrier offset 30 kHz < –98 dBc (1 Hz), –102 dBc (1 Hz) (typ.)
100 kHz < –100 dBc (1 Hz), –106 dBc (1 Hz) (typ.)
1 MHz < –125 dBc (1 Hz), –131 dBc (1 Hz) (typ.)
Level
Noise figure RF attenuation = 0 dB, RF preselection = off
10 MHz to 2.5 GHz < 28 dB
2.5 GHz to 3 GHz < 28 dB
3 GHz to 4 GHz < 34 dB
4 GHz to 7 GHz < 32 dB
7 GHz to 8 GHz < 43 dB
RF = 500 MHz 18 dB (typ.)
RF attenuation = 0 dB, RF preselection = on 1
10 MHz to 500 MHz < 17 dB
500 MHz to 3.6 GHz < 19 dB
3.6 GHz to 7 GHz < 23 dB
7 GHz to 8 GHz < 30 dB
RF = 500 MHz 11 dB (typ.)
Third-order intermodulation (TOI) RF attenuation = 5 dB, RF preselection = off
(nominal values) 50 MHz to 2 GHz 12 dBm
2 GHz to 8 GHz 15 dBm
RF attenuation = 5 dB, RF preselection = on 1
50 MHz to 200 MHz –3 dBm
200 MHz to 3.6 GHz 0 dBm
3.6 GHz to 8 GHz +3 dBm
Second-order intermodulation (SOI) RF = 500 MHz, RF attenuation = 5 dB
(nominal values) RF preselection = off 45 dBm
RF preselection = on 1 55 dBm
1
R&S®ETC-K1 option required.
Bandwidths
OFDM signal bandwidth range 1 MHz to 8 MHz
Resolution 0.1 Hz
Predefined channel filter bandwidths 5/6/7/8 MHz
Channel filter shape factor 80 dB:0.1 dB ≤ 1.09 (nom.)
Demodulation
Standard terrestrial TV in line with ETSI EN 300744 DVB-T, DVB-H
FFT mode automatic detection 2k, 4k, 8k
QAM order automatic detection 4QAM, 16QAM, 64QAM
QAM hierarchy automatic detection none, α = 1, 2, 4
Guard interval automatic detection 1/4, 1/8, 1/16, 1/32
Code rate automatic detection 1/2, 2/3, 3/4, 5/6, 7/8
Interleaver mode automatic detection native, in-depth
Inherent modulation error ratio RF attenuation = 0 dB, 64QAM nonhierarchical modulation,
(MER) 8k FFT, guard interval = 1/32, slow channel adaptation
level = –30 dBm, RF preselection = off
RF = 50 MHz to 862 MHz > 40 dB
RF = 500 MHz 45 dB (typ.)
level = –45 dBm, RF preselection = on 2
RF = 50 MHz to 862 MHz > 38 dB
RF = 500 MHz 44 dB (typ.)
Measurements
Measurement parameter list signal level, crest factor, carrier frequency offset, symbol rate offset, modulation error
ratio (MER RMS), modulation error ratio (MER peak), error vector magnitude
(EVM RMS), error vector magnitude (EVM peak), bit error ratio before Viterbi decoder,
bit error ratio before Reed-Solomon decoder, packet error ratio, packet errors per
second, MPEG transport stream rate
Transmission parameter signaling FFT, guard interval, QAM, hierarchy, code rate, cell ID, TPS reserved (frames 1 to 4),
(TPS) interleaver mode, MPE FEC, time slicing, length indicator
Constellation diagram QAM order 4QAM, 16QAM, 64QAM
QAM hierarchy none, α = 1, 2, 4
Echo pattern level range 50 dB
(channel impulse response) time range, extended span off Tsymbol/3
time range, extended span on Tsymbol
span units µs, km, miles
marker level resolution 0.1 dB
marker type relative level, absolute level
marker functions set to peak, set to next peak,
center = marker
echo pattern peak list 13 highest peaks with relative and
absolute level and time or distance
MER(k) MER range 10/20/50 dB
(modulation error ratio versus OFDM carrier range all modulated OFDM carriers
carriers) marker position units carrier number, relative frequency,
absolute frequency
marker MER resolution 0.1 dB
marker functions set to peak, set to next peak
trace detectors RMS, auto peak, min. peak, max. peak
TV spectrum lower and upper shoulder attenuation in line with ETSI TR 101290
in-channel amplitude frequency response, peak-to-peak
carrier to noise
occupied bandwidth
Spectrum emission mask spectrum emission test against emission mask
2
R&S®ETC-K1 option required.
Measurement uncertainty
Signal level 95 % confidence level, +20 °C to +30 °C, C/N > 16 dB, RF attenuation = auto
10 MHz to 3.6 GHz < 1 dB, 0.5 dB (typ.)
3.6 GHz to 8 GHz < 1.5 dB, 1 dB (typ.)
Crest factor < 0.5 dB (typ.)
Carrier frequency offset RF × reference uncertainty
Symbol rate offset reference uncertainty
MPEG TS bitrate MPEG TS bit rate × reference uncertainty
Modulation error ratio (MER) RF = 500 MHz, 64QAM, slow channel adaptation
20 dB to 30 dB < 1.0 dB (typ.)
30 dB to 35 dB < 1.5 dB (typ.)
35 dB to 40 dB < 2.0 dB (typ.)
Error vector magnitude (EVM) RF = 500 MHz, 64QAM, slow channel adaptation, referenced to measured value
0.65 % to 1.2 % < 25 %
1.2 % to 2 % < 20 %
2 % to 7 % < 12 %
BER before Viterbi decoder 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
–3 –15
BER before Reed-Solomon decoder 1.0 × 10 to 0.1 × 10 , 0.0 0.1 × 10–exponent
Packet error ratio 1.0 × 10–1 to 0.1 × 10–12, 0.0 0.1 × 10–exponent
Echo pattern peak level within guard interval < 0.5 dB (typ.)
Bandwidth
Channel filter bandwidth 6 MHz
Channel filter shape factor 75 dB:0.12 dB ≤ 1.10 (nom.)
Demodulation
Standard terrestrial TV in line with ARIB STD-B31 ISDB-T
ISDB-T mode automatic detection mode 1 (2k), mode 2 (4k), mode 3 (8k)
Modulation automatic detection DQPSK, QPSK, 16QAM, 64QAM
Layer automatic detection A, B, C
Partial reception automatic detection
Segments per layer automatic detection 13 in total (layer A + layer B + layer C)
Guard interval automatic detection 1/4, 1/8, 1/16, 1/32
Code rate (all layers) automatic detection 1/2, 2/3, 3/4, 5/6, 7/8
Interleaver mode mode 1 (2k FFT) 0, 4, 8, 16
mode 2 (4k FFT) 0, 2, 4, 8
mode 3 (8k FFT) 0, 1, 2, 4
Inherent modulation error ratio RF attenuation = 0 dB, 64QAM modulation,
(MER total, RMS) 8k FFT, guard interval = 1/32, slow channel adaptation
level = –30 dBm, RF preselection = off
RF = 50 MHz to 862 MHz > 40 dB
RF = 500 MHz 45 dB (typ.)
level = –45 dBm, RF preselection = on 2
RF = 50 MHz to 862 MHz > 38 dB
RF = 500 MHz 44 dB (typ.)
Measurements
Measurement parameter list signal level, crest factor, RF offset, symbol rate offset, total modulation error ratio
(MER total, RMS), total modulation error ratio (MER total, peak), modulation error ratio
of each layer (MER layer, RMS), modulation error ratio of TMCC (MER TMCC, RMS),
modulation error ratio of AC (MER AC, RMS), sideband position, bit error ratio before
Viterbi decoder, bit error ratio before Reed-Solomon decoder, bit error ratio after
Reed-Solomon decoder, packet errors per second, MPEG transport stream rate
Transmission and multiplexing ISDB-T mode, parameter switching indicator, emergency alarm broadcasting,
configuration control (TMCC) partial reception, phase shift correction, reserved bits, modulation, code rate,
time interleaving, number of segments
Constellation diagram QAM order DQPSK, QPSK, 16QAM, 64QAM
Echo pattern level range 50 dB
(channel impulse response) time range, extended span off Tsymbol/3
time range, extended span on Tsymbol
span units µs, km, miles
marker level resolution 0.1 dB
marker type relative level, absolute level
marker functions set to peak, set to next peak,
center = marker
echo pattern peak list 12 highest peaks with relative and
absolute level and time or distance
MER(k) MER range 10/20/50 dB
(modulation error ratio versus OFDM carrier range all modulated OFDM carriers
carriers) marker position units carrier number, relative frequency,
absolute frequency
marker MER resolution 0.1 dB
marker functions set to peak, set to next peak
trace detectors RMS, auto peak, min. peak, max. peak
TV spectrum lower and upper shoulder attenuation in line with ETSI TR 101290
in-channel amplitude frequency response, peak-to-peak
carrier to noise
occupied bandwidth
Spectrum emission mask spectrum emission test against emission mask
Measurement uncertainty
Signal level 95 % confidence level, +20 °C to +30 °C, C/N > 16 dB, RF attenuation = auto
10 MHz to 3.6 GHz < 1 dB, 0.5 dB (typ.)
3.6 GHz to 8 GHz < 1.5 dB, 1 dB (typ.)
Crest factor < 0.5 dB (typ.)
RF offset RF × reference uncertainty
Symbol rate offset reference uncertainty
MPEG TS bitrate MPEG TS bit rate × reference uncertainty
Modulation error ratio RF = 500 MHz, slow channel adaptation
20 dB to 30 dB < 1.0 dB (typ.)
30 dB to 35 dB < 1.5 dB (typ.)
35 dB to 40 dB < 2.0 dB (typ.)
BER before Viterbi decoder 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
BER before Reed-Solomon decoder 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
BER after Reed-Solomon decoder 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
Echo pattern peak level within guard interval < 0.5 dB (typ.)
Bandwidths
OFDM signal bandwidth range 1.7/5/6/7/8 MHz
Resolution 0.1 Hz
Predefined channel filter bandwidths 1.7/5/6/7/8 MHz
Channel filter shape factor 50 dB:0.035 dB ≤ 1.11
50 dB:0.16 dB ≤ 1.08
Demodulation
Standard terrestrial TV in line with ETSI EN 302755 manual selection: T2 lite and T2 base
version 1.3.1: DVB-T2 base, automatic detection: T2 base, T2 base lite
DVB-T2 base lite, DVB-T2 lite
FFT mode automatic detection 1k, 2k, 4k, 8k, 16k, 32k
normal or extended carrier mode
Pilot pattern automatic detection PP1, PP2, PP3, PP4, PP5, PP6, PP7,
PP8 (PP8 for measurements at the
transmitter site only)
QAM order automatic detection 4QAM, 16QAM, 64QAM, 256QAM
normal or rotated constellation
Guard interval automatic detection 1/4, 19/128, 1/8, 19/256, 1/16, 1/32, 1/128
PLP code rate automatic detection for single PLP 1/2, 3/5, 2/3, 3/4, 4/5, 5/6 for DVB-T2 base
1/2, 3/5, 2/3, 3/4, 1/3, 2/5 for DVB-T2 lite
FEC type LDPC + BCH
Time interleaver type in line with standard: single or multi
OFDM signal bandwidth range 1.7/5/6/7/8 MHz
Inherent modulation error ratio RF attenuation = 0 dB, 256QAM modulation,
(MER) 32k extended FFT, guard interval = 1/128, slow channel adaptation
level = –30 dBm, RF preselection = off
RF = 50 MHz to 862 MHz > 40 dB
RF = 500 MHz 44 dB (typ.)
level = –45 dBm, RF preselection = on 3
RF = 50 MHz to 862 MHz > 38 dB
RF = 500 MHz 43 dB (typ.)
Measurements
Measurement parameter list signal level, crest factor, carrier frequency offset, symbol rate offset, modulation error
ratio (MER L1-RMS), modulation error ratio (MER L1-peak), modulation error ratio
(MER PLP-RMS), modulation error ratio (MER PLP-peak), error vector magnitude
(EVM PLP-RMS), error vector magnitude (EVM PLP-peak), LDPC iterations, bit error
ratio before LDPC/BCH, BBFrame, TS packet error ratio
Signaling info L1 presignaling info T2 version, transmission system, guard
(L1 presignaling, PLP parameter and interval, pilot pattern, bandwidth
auxiliary L1 post info) extension, number of data symbols per
T2 frame, number of T2 frames per
superframe, PAPR, system ID, cell ID,
network ID, S1 bits, S2 bits, CRC32,
L1 post constellation, L1 post code rate,
L1 post FEC type, L1 post extension,
L1 post size, L1 post info size, L1
repetition, type of TX input streams,
TX ID availability, regeneration flag,
number of frequencies, current RF index,
reserved
3
R&S®ETC-K1 option required.
Measurement uncertainty
Signal level 95 % confidence level, +20 °C to +30 °C, C/N > 16 dB, RF attenuation = auto
10 MHz to 3.6 GHz < 1 dB, 0.5 dB (typ.)
3.6 GHz to 8 GHz < 1.5 dB, 1 dB (typ.)
Crest factor < 0.5 dB (typ.)
Carrier frequency offset RF × reference uncertainty
Symbol rate offset reference uncertainty
MPEG TS bitrate MPEG TS bit rate × reference uncertainty
Modulation error ratio (MER) RF = 500 MHz, 64QAM, slow channel adaptation
20 dB to 30 dB < 1.0 dB (typ.)
30 dB to 35 dB < 1.5 dB (typ.)
35 dB to 40 dB < 2.0 dB (typ.)
Error vector magnitude (EVM) RF = 500 MHz, 64QAM, slow channel adaptation, referenced to measured value
0.65 % to 1.2 % < 25 %
1.2 % to 2 % < 20 %
2 % to 7 % < 12 %
BER before LDPC or BCH 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
BB frame error ratio 1.0 × 10–1 to 0.1 × 10–12, 0.0 0.1 × 10–exponent
–1 –12
TS packet error ratio 1.0 × 10 to 0.1 × 10 , 0.0 0.1 × 10–exponent
Spectrum analysis
Frequency
Frequency range model .04 100 kHz to 3.6 GHz
model .08 100 kHz to 8 GHz
Resolution 1 Hz
Reference frequency, internal
Aging per year 1 × 10–6
Temperature drift 0 °C to +30 °C 1 × 10–6
+30 °C to +50 °C 3 × 10–6
Achievable initial calibration accuracy 5 × 10–7
Total reference uncertainty 0 °C to +30 °C (time since last adjustment × aging rate) +
temperature drift + calibration accuracy
Reference frequency, with R&S®HA-Z240 option
Frequency uncertainty GPS on, ≥ 1 minute after satellite lock 2.5 × 10–8
up to 30 minutes after losing satellite lock 5 × 10–8
Frequency readout
Marker resolution 0.1 Hz
Uncertainty ±(marker frequency × reference
uncertainty + 10 % × resolution bandwidth
+ ½ (span / (sweep points – 1)) + 1 Hz)
Number of sweep (trace) points default value 631
Marker tuning frequency step size span/630
Frequency counter resolution 0.1 Hz
Frequency counter uncertainty S/N > 25 dB ±(frequency × reference uncertainty +
½ (last digit))
with R&S®HAZ240 option
GPS on, ≥ 1 minute after satellite lock 2.5 × 10–8
up to 30 minutes after losing satellite 5 × 10–8
lock
Frequency span 0 Hz, 10 Hz to 3.6/8 GHz
Frequency span uncertainty 1 % (nom.)
Spectral purity of SSB phase noise RF = 500 MHz
Carrier offset 30 kHz < –98 dBc (1 Hz), –102 dBc (1 Hz) (typ.)
100 kHz < –100 dBc (1 Hz), –106 dBc (1 Hz) (typ.)
1 MHz < –125 dBc (1 Hz), –131 dBc (1 Hz) (typ.)
Sweep time
Sweep time span = 0 Hz 200 µs to 100 s
10 Hz ≤ span ≤ 600 MHz 20 ms to 1000 s
span > 600 MHz 20 ms × span/600 MHz to 1000 s
Uncertainty span = 0 Hz 1 % (nom.)
span ≥ 10 Hz 3 % (nom.)
Bandwidths
Resolution bandwidths
Range –3 dB bandwidth 100 Hz to 3 MHz in 1, 3 sequence
Bandwidth accuracy 100 Hz ≤ RBW ≤ 300 kHz < 5 % (nom.)
RBW > 300 kHz < 10 % (nom.)
Selectivity 60 dB:3 dB < 5 (nom.) (Gaussian type filters)
Video filters
Range –3 dB bandwidth 10 Hz to 3 MHz in 1, 3 sequence
RF preselection (R&S®ETC-K1 option)
Lower 3 dB cut-off frequency RF up to 80 MHz 500 kHz
80 MHz to 200 MHz RF – 15 MHz
0.2 GHz to 1.5 GHz 0.9 × RF
1.5 GHz to 3.6 GHz 1.3 GHz
3.6 GHz to 8 GHz 3.2 GHz
Upper 3 dB cut-off frequency RF up to 80 MHz 80 MHz
80 MHz to 200 MHz RF + 15 MHz
0.2 GHz to 1.5 GHz 1.1 × RF
1.5 GHz to 3.6 GHz 3.7 GHz
3.6 GHz to 8 GHz 8 GHz
Level
Display range displayed noise floor to +20 dBm
Maximum rated input level (nominal values)
DC voltage 80 V
RF power 27 dBm (= 0.5 W)
CW RF power 30 dBm (= 1 W)
Peak RF power duration < 3 s 33 dBm (= 2 W)
Max. pulse voltage 100 V
Max. pulse energy pulse width = 10 µs 10 mWs
Intermodulation
Third-order intermodulation (TOI) intermodulation-free dynamic range, signal level 2 × –15 dBm, RF attenuation = 5 dB,
(nominal values) RF preselection = off
50 MHz to 2 GHz 54 dBc (TOI +12 dBm)
2 GHz to 8 GHz 60 dBc (TOI +15 dBm)
intermodulation-free dynamic range, signal level 2 × –30 dBm, RF attenuation = 5 dB,
RF preselection = on 4
50 MHz to 200 MHz 54 dBc (TOI –3 dBm)
200 MHz to 3.6 GHz 60 dBc (TOI 0 dBm)
3.6 GHz to 8 GHz 66 dBc (TOI +3 dBm)
Second-order intermodulation (SOI) signal level 2 × –30 dBm (250.0 MHz and 250.1 MHz), RF attenuation = 5 dB,
(nominal values) RF preselection = off
500 MHz 45 dBm
signal level 2 × –30 dBm (250.0 MHz and 250.1 MHz), RF attenuation = 5 dB,
RF preselection = on 4
500 MHz 55 dBm
Displayed average noise level RF attenuation = 0 dB, termination = 50 Ω, RBW = 1 kHz, VBW = 10 Hz, sample
detector, trace average 10, log scaling, tracking generator off, normalized to 1 Hz
RF preselection = off
100 kHz to 1 MHz < –125 dBm, –129 dBm (typ.)
1 MHz to 10 MHz < –148 dBm, –153 dBm (typ.)
10 MHz to 2.5 GHz < –151 dBm, –157 dBm (typ.)
2.5 GHz to 3 GHz < –148 dBm, –154 dBm (typ.)
3 GHz to 4 GHz < –144 dBm, –150 dBm (typ.)
4 GHz to 7 GHz < –145 dBm, –151 dBm (typ.)
7 GHz to 8 GHz < –133 dBm, –137 dBm (typ.)
RF preselection = on 4
1 MHz to 10 MHz < –154 dBm, –160 dBm (typ.)
10 MHz to 500 MHz < –160 dBm, –165 dBm (typ.)
500 MHz to 3.6 GHz < –158 dBm, –163 dBm (typ.)
3.6 GHz to 7 GHz < –154 dBm, –160 dBm (typ.)
7 GHz to 8 GHz < –146 dBm, –151 dBm (typ.)
Immunity to interference (nominal values)
Image frequencies fin – 2 × 21.4 MHz –63 dBc
fin – 2 × 830.4 MHz –80 dBc
fin – 2 × 4875.4 MHz –90 dBc
Intermediate frequencies 21.4 MHz –60 dBc
830.4 MHz, 4875.4 MHz, 8920.4 MHz –80 dBc
Spurious response, inherent input matched to 50 Ω, without input signal, RBW ≤ 30 kHz, RF attenuation = 0 dB
RF preselection = off < –90 dBm
RF preselection = on 4 < –100 dBm
Other interfering signals signal level – RF attenuation < –30 dBm, RF preselection = off
10.7 MHz –60 dBc
2437.7 MHz –60 dBc
signal level – RF attenuation < –30 dBm, RF preselection = off, RF ≤ 3.6 GHz
spurious at fin – 2437.7 MHz –80 dBc
signal level – RF attenuation < –40 dBm, RF preselection = off, RF ≥ 3.6 GHz
4460.2 MHz –40 dBc
4
R&S®ETC-K1 option required.
Trigger functions
Trigger
Trigger source free run, video, external
External trigger level threshold low → high transition
high → low transition
5
R&S®ETC-K1 option required.
General data
Operating languages English, Russian, Spanish, Italian,
Portuguese, Japanese
Remote control
Command set SCPI 1997.0
LAN interface 10/100BASE-T, RJ-45
USB rear panel USB device, type B
Display
Type 14.5 cm (5.7 in) LCD TFT color
Resolution 640 × 480 pixel
Audio
Speaker internal
Mass memory
Mass memory flash memory (internal)
SD card (internal, 8 Gbyte)
USB memory stick (not supplied),
support up to 16 Gbyte (FAT32)
Data storage internal > 256 instrument settings and traces
8 Gbyte SD card or USB memory stick > 40000 instrument settings and traces
Temperature operating temperature range +5 °C to +40 °C
permissible temperature range 0 °C to +50 °C
storage temperature range –40 °C to +70 °C
Climatic loading relative humidity +25 °C/+40 °C at 95 % relative humidity
IEC 60068-2-30
Mechanical resistance
Vibration sinusoidal IEC 60068-2-6
random IEC 60068-2-64
Shock 40 g shock spectrum,
in line with MIL-STD-810E, method 516.4,
procedure 1, IEC 60068-2-27
Power supply
AC power supply input specifications 100 V to 240 V AC, 50 Hz to 60 Hz,
400 Hz, 150 VA
Input current AC 0.9 to 0.3 A
Power consumption 85 VA (typ.), max. 140 VA with all options
Power consumption TV analyzer mode
(based on AC input 230 V, 50 Hz) with ISDB-T 21.2 W
with ISDB-T and 31.3 W
R&S®ETC-B280 option
with DVB-T/DVB-H 22.5 W
with DVB-T/DVB-H and 32.7 W
R&S®ETC-B280 option
with DVB-T2 32.0 W
with DVB-T2 and 42.2 W
R&S®ETC-B280 option
spectrum analyzer mode
15.0 W
with R&S®ETC-B280 option 23.8 W
Safety IEC 61010-1, EN 61010-1, UL 61010-1,
CSA C22.2 No. 61010-1
Test mark VDE, GS, CSA, KC
EMC in line with European EMC Directive
2004/108/EC, including
IEC/EN 61326 class A (emission),
CISPR 11/EN 55011/group 1
class A (emission),
IEC/EN 61326 table A.1
(immunity, industrial)
Dimensions W×H×D 233 mm × 158 mm × 350 mm
(9.2 in × 6.2 in × 13.8 in)
Weight 4.8 kg (10.6 lb)
Recommended calibration interval 1 year
Accessories
6 1000
AVG AVG
AVG –10 °C to +35 °C (max. 10 ms)
800
–10 °C to +35 °C
4
600
Forward power/W
AVG
400 –10 °C to +50 °C
Error limits/dB
200
–2
–4 100
0 5 10 15 20 25 25 100 200 400 600 800 1000
Return loss/dB Frequency/MHz
6
1000
800
4 AVG –10 °C to +35 °C
600
Forward power/W
Measurement error/dB
2
400
200
–2
–4 100
0 5 10 15 20 25 0.2 0.4 0.7 1 2 3 4
Return loss/dB Frequency/GHz
Ordering information
Designation Type Order No.
Base unit
Compact TV Analyzer, up to 3.6 GHz R&S®ETC 2116.5000.04
Compact TV Analyzer, up to 8 GHz R&S®ETC 2116.5000.08
Accessories supplied
USB cable, quick reference guide and CD-ROM with R&S®ETCView PC software and documentation
Hardware option
FPGA Extension Board R&S®ETC-B300 2116.5230.02
MPEG Decoder Board (requires at least one digital TV standard R&S®ETC-B280 2116.5252.02
R&S®ETC-K140, R&S®ETC-K160 or R&S®ETC-K240)
Software options
RF Preselection, up to 3.6 GHz R&S®ETC-K1 2116.5098.02
RF Preselection, up to 8 GHz R&S®ETC-K1 2116.5181.02
Tracking Generator with Scalar Network Analysis, up to 3.6 GHz R&S®ETC-K10 2116.5169.02
Tracking Generator with Scalar Network Analysis, up to 8 GHz R&S®ETC-K10 2116.5175.02
Phase and Group Delay Measurement R&S®ETC-K180 2116.5130.02
(requires at least one TV standard)
DVB-T/DVB-H Analysis R&S®ETC-K140 2116.5100.02
ISDB-T Analysis R&S®ETC-K160 2116.5117.02
DVB-T2 Analysis (requires R&S®ETC-B300) R&S®ETC-K240 2116.5123.02
Software application tools for DVB-T2, DVB-T and ISDB-T
Broadcast Drive Test R&S®ETC-K930 2116.5146.02
Automatic Transmitter Measurement, TXCheck R&S®ETC-K940 2116.5152.02
External accessories
GPS Receiver R&S®HA-Z240 1309.6700.03
Directional Power Sensor, 25 MHz to 1 GHz R&S®FSH-Z14 1120.6001.02
Directional Power Sensor, 200 MHz to 4 GHz R&S®FSH-Z44 1165.2305.02
Wideband Power Sensor, 50 MHz to 18 GHz, 100 mW R&S®NRP-Z81 1137.9009.02
Soft Carrying Bag R&S®RTM-Z3 1305.0289.02
R&S®ETC Hard Case R&S®ETC-Z1 2116.5300.00
Warranty
Base unit 3 years
All other items 1 year
Options
Extended Warranty, one year R&S®WE1 Please contact your local
Extended Warranty, two years R&S®WE2 Rohde & Schwarz sales office.
Extended Warranty with Calibration Coverage, one year R&S®CW1
Extended Warranty with Calibration Coverage, two years R&S®CW2
Extended warranty with a term of one and two years (WE1 and WE2)
Repairs carried out during the contract term are free of charge 6. Necessary calibration and adjustments carried out during repairs are
also covered.
6
Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included.
Regional contact
❙❙ Europe, Africa, Middle East | +49 89 4129 12345
customersupport@rohde-schwarz.com
❙❙ North America | 1 888 TEST RSA (1 888 837 87 72)
customer.support@rsa.rohde-schwarz.com
❙❙ Latin America | +1 410 910 79 88
customersupport.la@rohde-schwarz.com
❙❙ Asia Pacific | +65 65 13 04 88
customersupport.asia@rohde-schwarz.com
❙❙ China | +86 800 810 82 28 | +86 400 650 58 96
customersupport.china@rohde-schwarz.com
3606697022