R&S®ETC

Compact TV Analyzer
Specifications

year

Data Sheet | Version 06.00

ETC_dat-sw_en_3606-6970-22_v0600_cover.indd 1 02.11.2017 14:55:07


Version 06.00, November 2017

CONTENTS
Definitions ....................................................................................................................................................................... 3
Specifications .................................................................................................................................................................. 4
TV analyzer ...................................................................................................................................................................... 4
Frequency ......................................................................................................................................................................................... 4

Level.................................................................................................................................................................................................. 4

RF preselection (R&S®ETC-K1 option) .............................................................................................................................................. 5

DVB-T/DVB-H analysis (R&S®ETC-K140 option) ............................................................................................................................... 6

ISDB-T analysis (R&S®ETC-K160 option) .......................................................................................................................................... 8

DVB-T2 analysis (R&S®ETC-K240 option, requires R&S®ETC-B300) .............................................................................................. 10

Amplitude/phase/group delay measurement (R&S®ETC-K180 option) ............................................................................................. 12

MPEG decoder board (R&S®ETC-B280 option, requires at least one digital TV standard R&S®ETC-K140, R&S®ETC-K160 or
R&S®ETC-K240).............................................................................................................................................................................. 13

Spectrum analysis ........................................................................................................................................................ 14


Frequency ....................................................................................................................................................................................... 14

Sweep time...................................................................................................................................................................................... 14

Bandwidths ...................................................................................................................................................................................... 14

Level................................................................................................................................................................................................ 15

Trigger functions .............................................................................................................................................................................. 16

Scalar network analysis (R&S®ETC-K10 option) ........................................................................................................ 17


Inputs and outputs ........................................................................................................................................................ 18
General data .................................................................................................................................................................. 19
Accessories ................................................................................................................................................................... 20
R&S®FSH-Z14 directional power sensor .......................................................................................................................................... 20

R&S®FSH-Z44 directional power sensor .......................................................................................................................................... 22

R&S®HA-Z240 GPS receiver ........................................................................................................................................................... 24

Ordering information .................................................................................................................................................... 25

2 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

Definitions
General
Product data applies under the following conditions:

 Three hours storage at ambient temperature followed by 30 minutes warm-up operation


 Specified environmental conditions met
 Recommended calibration interval adhered to
 All internal automatic adjustments performed, if applicable

Specifications with limits


Represent warranted product performance by means of a range of values for the specified parameter. These specifications are
marked with limiting symbols such as <, ≤, >, ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by
testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift
and aging, if applicable.

Specifications without limits


Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent
values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is
ensured by design.

Typical data (typ.)


Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a
range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the
mean value.

Nominal values (nom.)


Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to
typical data, a statistical evaluation does not take place and the parameter is not tested during production.

Measured values (meas.)


Characterize expected product performance by means of measurement results gained from individual samples.

Uncertainties
Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been
calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account
environmental conditions, aging, wear and tear.

Device settings and GUI parameters are designated with the format “parameter: value”.

Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz.

Rohde & Schwarz R&S®ETC Compact TV Analyzer 3


Version 06.00, November 2017

Specifications
TV analyzer
Frequency
Frequency range model .04 4.5 MHz to 3.6 GHz
model .08 4.5 MHz to 8 GHz
Resolution 1 Hz
Reference frequency, internal
Aging per year 1 × 10–6
Temperature drift 0 °C to +30 °C 1 × 10–6
+30 °C to +50 °C 3 × 10–6
Achievable initial calibration accuracy 5 × 10–7
Total reference uncertainty 0 °C to +30 °C (time since last adjustment × aging rate)
+ temperature drift + calibration accuracy
Reference frequency, with R&S®HA-Z240 option
Frequency uncertainty GPS on, ≥ 1 minute after satellite lock 2.5 × 10–8
up to 30 minutes after losing satellite lock 5 × 10–8
Spectral purity of SSB phase noise RF = 500 MHz
Carrier offset 30 kHz < –98 dBc (1 Hz), –102 dBc (1 Hz) (typ.)
100 kHz < –100 dBc (1 Hz), –106 dBc (1 Hz) (typ.)
1 MHz < –125 dBc (1 Hz), –131 dBc (1 Hz) (typ.)

Level
Noise figure RF attenuation = 0 dB, RF preselection = off
10 MHz to 2.5 GHz < 28 dB
2.5 GHz to 3 GHz < 28 dB
3 GHz to 4 GHz < 34 dB
4 GHz to 7 GHz < 32 dB
7 GHz to 8 GHz < 43 dB
RF = 500 MHz 18 dB (typ.)
RF attenuation = 0 dB, RF preselection = on 1
10 MHz to 500 MHz < 17 dB
500 MHz to 3.6 GHz < 19 dB
3.6 GHz to 7 GHz < 23 dB
7 GHz to 8 GHz < 30 dB
RF = 500 MHz 11 dB (typ.)
Third-order intermodulation (TOI) RF attenuation = 5 dB, RF preselection = off
(nominal values) 50 MHz to 2 GHz 12 dBm
2 GHz to 8 GHz 15 dBm
RF attenuation = 5 dB, RF preselection = on 1
50 MHz to 200 MHz –3 dBm
200 MHz to 3.6 GHz 0 dBm
3.6 GHz to 8 GHz +3 dBm
Second-order intermodulation (SOI) RF = 500 MHz, RF attenuation = 5 dB
(nominal values) RF preselection = off 45 dBm
RF preselection = on 1 55 dBm

1
R&S®ETC-K1 option required.

4 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

Immunity to interference (nominal values)


Image frequencies, fin – 2 × 20.8 MHz –63 dB
referenced to signal level fin – 2 × 829.8 MHz –80 dB
fin – 2 × 4874.8 MHz –90 dB
Intermediate frequencies, 20.8 MHz –60 dB
referenced to signal level 829.8 MHz, 4874.8 MHz, 8919.8 MHz –80 dB
Other interfering signals, signal level – RF attenuation < –30 dBm, RF preselection = off
referenced to signal level 10.4 MHz –60 dB
2437.4 MHz –60 dB
signal level – RF attenuation < –30 dBm, RF preselection = off, RF ≤ 3.6 GHz
spurious at fin – 2437.4 MHz –80 dB
signal level – RF attenuation < –40 dBm, RF preselection = off, RF ≥ 3.6 GHz
4459.9 MHz –40 dB
Spurious response, inherent input matched to 50 Ω, without input signal, RF attenuation = 0 dB
RF preselection = off < –90 dBm
RF preselection = on 1 < –100 dBm
Maximum rated input level (nominal values)
DC voltage 80 V
RF power 27 dBm (= 0.5 W)
CW RF power 30 dBm (= 1 W)
Peak RF power duration < 3 s 33 dBm (= 2 W)
Max. pulse voltage 100 V
Max. pulse energy pulse width = 10 µs 10 mWs

RF preselection (R&S®ETC-K1 option)


Lower 3 dB cut-off frequency RF up to 80 MHz 500 kHz
80 MHz to 200 MHz RF – 15 MHz
0.2 GHz to 1.5 GHz 0.9 × RF
1.5 GHz to 3.6 GHz 1.3 GHz
3.6 GHz to 8 GHz 3.2 GHz
Upper 3 dB cut-off frequency RF up to 80 MHz 80 MHz
80 MHz to 200 MHz RF + 15 MHz
0.2 GHz to 1.5 GHz 1.1 × RF
1.5 GHz to 3.6 GHz 3.7 GHz
3.6 GHz to 8 GHz 8 GHz

Rohde & Schwarz R&S®ETC Compact TV Analyzer 5


Version 06.00, November 2017

DVB-T/DVB-H analysis (R&S®ETC-K140 option)


Level
Quasi-error-free input level RF = 500 MHz, RF attenuation = 0 dB, BER before RS < 2.0 × 10–4,
64QAM nonhierarchical modulation, guard interval = 1/32, code rate = 3/4
RF preselection = off < –64 dBm, –69 dBm to +10 dBm (typ.)
RF preselection = on 1 < –72 dBm, –75 dBm to +10 dBm (typ.)

Bandwidths
OFDM signal bandwidth range 1 MHz to 8 MHz
Resolution 0.1 Hz
Predefined channel filter bandwidths 5/6/7/8 MHz
Channel filter shape factor 80 dB:0.1 dB ≤ 1.09 (nom.)
Demodulation
Standard terrestrial TV in line with ETSI EN 300744 DVB-T, DVB-H
FFT mode automatic detection 2k, 4k, 8k
QAM order automatic detection 4QAM, 16QAM, 64QAM
QAM hierarchy automatic detection none, α = 1, 2, 4
Guard interval automatic detection 1/4, 1/8, 1/16, 1/32
Code rate automatic detection 1/2, 2/3, 3/4, 5/6, 7/8
Interleaver mode automatic detection native, in-depth
Inherent modulation error ratio RF attenuation = 0 dB, 64QAM nonhierarchical modulation,
(MER) 8k FFT, guard interval = 1/32, slow channel adaptation
level = –30 dBm, RF preselection = off
RF = 50 MHz to 862 MHz > 40 dB
RF = 500 MHz 45 dB (typ.)
level = –45 dBm, RF preselection = on 2
RF = 50 MHz to 862 MHz > 38 dB
RF = 500 MHz 44 dB (typ.)

Measurements
Measurement parameter list signal level, crest factor, carrier frequency offset, symbol rate offset, modulation error
ratio (MER RMS), modulation error ratio (MER peak), error vector magnitude
(EVM RMS), error vector magnitude (EVM peak), bit error ratio before Viterbi decoder,
bit error ratio before Reed-Solomon decoder, packet error ratio, packet errors per
second, MPEG transport stream rate
Transmission parameter signaling FFT, guard interval, QAM, hierarchy, code rate, cell ID, TPS reserved (frames 1 to 4),
(TPS) interleaver mode, MPE FEC, time slicing, length indicator
Constellation diagram QAM order 4QAM, 16QAM, 64QAM
QAM hierarchy none, α = 1, 2, 4
Echo pattern level range 50 dB
(channel impulse response) time range, extended span off Tsymbol/3
time range, extended span on Tsymbol
span units µs, km, miles
marker level resolution 0.1 dB
marker type relative level, absolute level
marker functions set to peak, set to next peak,
center = marker
echo pattern peak list 13 highest peaks with relative and
absolute level and time or distance
MER(k) MER range 10/20/50 dB
(modulation error ratio versus OFDM carrier range all modulated OFDM carriers
carriers) marker position units carrier number, relative frequency,
absolute frequency
marker MER resolution 0.1 dB
marker functions set to peak, set to next peak
trace detectors RMS, auto peak, min. peak, max. peak
TV spectrum lower and upper shoulder attenuation in line with ETSI TR 101290
in-channel amplitude frequency response, peak-to-peak
carrier to noise
occupied bandwidth
Spectrum emission mask spectrum emission test against emission mask

2
R&S®ETC-K1 option required.

6 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

Measurement uncertainty
Signal level 95 % confidence level, +20 °C to +30 °C, C/N > 16 dB, RF attenuation = auto
10 MHz to 3.6 GHz < 1 dB, 0.5 dB (typ.)
3.6 GHz to 8 GHz < 1.5 dB, 1 dB (typ.)
Crest factor < 0.5 dB (typ.)
Carrier frequency offset RF × reference uncertainty
Symbol rate offset reference uncertainty
MPEG TS bitrate MPEG TS bit rate × reference uncertainty
Modulation error ratio (MER) RF = 500 MHz, 64QAM, slow channel adaptation
20 dB to 30 dB < 1.0 dB (typ.)
30 dB to 35 dB < 1.5 dB (typ.)
35 dB to 40 dB < 2.0 dB (typ.)
Error vector magnitude (EVM) RF = 500 MHz, 64QAM, slow channel adaptation, referenced to measured value
0.65 % to 1.2 % < 25 %
1.2 % to 2 % < 20 %
2 % to 7 % < 12 %
BER before Viterbi decoder 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
–3 –15
BER before Reed-Solomon decoder 1.0 × 10 to 0.1 × 10 , 0.0 0.1 × 10–exponent
Packet error ratio 1.0 × 10–1 to 0.1 × 10–12, 0.0 0.1 × 10–exponent
Echo pattern peak level within guard interval < 0.5 dB (typ.)

Rohde & Schwarz R&S®ETC Compact TV Analyzer 7


Version 06.00, November 2017

ISDB-T analysis (R&S®ETC-K160 option)


Level
Quasi-error-free input level RF = 500 MHz, RF attenuation = 0 dB, BER before RS < 2.0 × 10–4,
(nominal values) 64QAM modulation, guard interval = 1/32, code rate = 3/4
RF preselection = off < –64 dBm, –69 dBm to +10 dBm (typ.)
RF preselection = on 2 < –72 dBm, –75 dBm to +10 dBm (typ.)

Bandwidth
Channel filter bandwidth 6 MHz
Channel filter shape factor 75 dB:0.12 dB ≤ 1.10 (nom.)

Demodulation
Standard terrestrial TV in line with ARIB STD-B31 ISDB-T
ISDB-T mode automatic detection mode 1 (2k), mode 2 (4k), mode 3 (8k)
Modulation automatic detection DQPSK, QPSK, 16QAM, 64QAM
Layer automatic detection A, B, C
Partial reception automatic detection
Segments per layer automatic detection 13 in total (layer A + layer B + layer C)
Guard interval automatic detection 1/4, 1/8, 1/16, 1/32
Code rate (all layers) automatic detection 1/2, 2/3, 3/4, 5/6, 7/8
Interleaver mode mode 1 (2k FFT) 0, 4, 8, 16
mode 2 (4k FFT) 0, 2, 4, 8
mode 3 (8k FFT) 0, 1, 2, 4
Inherent modulation error ratio RF attenuation = 0 dB, 64QAM modulation,
(MER total, RMS) 8k FFT, guard interval = 1/32, slow channel adaptation
level = –30 dBm, RF preselection = off
RF = 50 MHz to 862 MHz > 40 dB
RF = 500 MHz 45 dB (typ.)
level = –45 dBm, RF preselection = on 2
RF = 50 MHz to 862 MHz > 38 dB
RF = 500 MHz 44 dB (typ.)
Measurements
Measurement parameter list signal level, crest factor, RF offset, symbol rate offset, total modulation error ratio
(MER total, RMS), total modulation error ratio (MER total, peak), modulation error ratio
of each layer (MER layer, RMS), modulation error ratio of TMCC (MER TMCC, RMS),
modulation error ratio of AC (MER AC, RMS), sideband position, bit error ratio before
Viterbi decoder, bit error ratio before Reed-Solomon decoder, bit error ratio after
Reed-Solomon decoder, packet errors per second, MPEG transport stream rate
Transmission and multiplexing ISDB-T mode, parameter switching indicator, emergency alarm broadcasting,
configuration control (TMCC) partial reception, phase shift correction, reserved bits, modulation, code rate,
time interleaving, number of segments
Constellation diagram QAM order DQPSK, QPSK, 16QAM, 64QAM
Echo pattern level range 50 dB
(channel impulse response) time range, extended span off Tsymbol/3
time range, extended span on Tsymbol
span units µs, km, miles
marker level resolution 0.1 dB
marker type relative level, absolute level
marker functions set to peak, set to next peak,
center = marker
echo pattern peak list 12 highest peaks with relative and
absolute level and time or distance
MER(k) MER range 10/20/50 dB
(modulation error ratio versus OFDM carrier range all modulated OFDM carriers
carriers) marker position units carrier number, relative frequency,
absolute frequency
marker MER resolution 0.1 dB
marker functions set to peak, set to next peak
trace detectors RMS, auto peak, min. peak, max. peak
TV spectrum lower and upper shoulder attenuation in line with ETSI TR 101290
in-channel amplitude frequency response, peak-to-peak
carrier to noise
occupied bandwidth
Spectrum emission mask spectrum emission test against emission mask

8 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

Measurement uncertainty
Signal level 95 % confidence level, +20 °C to +30 °C, C/N > 16 dB, RF attenuation = auto
10 MHz to 3.6 GHz < 1 dB, 0.5 dB (typ.)
3.6 GHz to 8 GHz < 1.5 dB, 1 dB (typ.)
Crest factor < 0.5 dB (typ.)
RF offset RF × reference uncertainty
Symbol rate offset reference uncertainty
MPEG TS bitrate MPEG TS bit rate × reference uncertainty
Modulation error ratio RF = 500 MHz, slow channel adaptation
20 dB to 30 dB < 1.0 dB (typ.)
30 dB to 35 dB < 1.5 dB (typ.)
35 dB to 40 dB < 2.0 dB (typ.)
BER before Viterbi decoder 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
BER before Reed-Solomon decoder 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
BER after Reed-Solomon decoder 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
Echo pattern peak level within guard interval < 0.5 dB (typ.)

Rohde & Schwarz R&S®ETC Compact TV Analyzer 9


Version 06.00, November 2017

DVB-T2 analysis (R&S®ETC-K240 option, requires R&S®ETC-B300)


Level
Quasi-error-free input level RF = 500 MHz, RF attenuation = 0 dB, BER before BCH < 1.0 × 10–7,
32k extended FFT, 64QAM modulation, guard interval = 1/128, code rate = 3/5
RF preselection = off < –64 dBm, –69 dBm to +10 dBm (typ.)
RF preselection = on 3 < –72 dBm, –75 dBm to +10 dBm (typ.)

Bandwidths
OFDM signal bandwidth range 1.7/5/6/7/8 MHz
Resolution 0.1 Hz
Predefined channel filter bandwidths 1.7/5/6/7/8 MHz
Channel filter shape factor 50 dB:0.035 dB ≤ 1.11
50 dB:0.16 dB ≤ 1.08

Demodulation
Standard terrestrial TV in line with ETSI EN 302755 manual selection: T2 lite and T2 base
version 1.3.1: DVB-T2 base, automatic detection: T2 base, T2 base lite
DVB-T2 base lite, DVB-T2 lite
FFT mode automatic detection 1k, 2k, 4k, 8k, 16k, 32k
normal or extended carrier mode
Pilot pattern automatic detection PP1, PP2, PP3, PP4, PP5, PP6, PP7,
PP8 (PP8 for measurements at the
transmitter site only)
QAM order automatic detection 4QAM, 16QAM, 64QAM, 256QAM
normal or rotated constellation
Guard interval automatic detection 1/4, 19/128, 1/8, 19/256, 1/16, 1/32, 1/128
PLP code rate automatic detection for single PLP 1/2, 3/5, 2/3, 3/4, 4/5, 5/6 for DVB-T2 base
1/2, 3/5, 2/3, 3/4, 1/3, 2/5 for DVB-T2 lite
FEC type LDPC + BCH
Time interleaver type in line with standard: single or multi
OFDM signal bandwidth range 1.7/5/6/7/8 MHz
Inherent modulation error ratio RF attenuation = 0 dB, 256QAM modulation,
(MER) 32k extended FFT, guard interval = 1/128, slow channel adaptation
level = –30 dBm, RF preselection = off
RF = 50 MHz to 862 MHz > 40 dB
RF = 500 MHz 44 dB (typ.)
level = –45 dBm, RF preselection = on 3
RF = 50 MHz to 862 MHz > 38 dB
RF = 500 MHz 43 dB (typ.)
Measurements
Measurement parameter list signal level, crest factor, carrier frequency offset, symbol rate offset, modulation error
ratio (MER L1-RMS), modulation error ratio (MER L1-peak), modulation error ratio
(MER PLP-RMS), modulation error ratio (MER PLP-peak), error vector magnitude
(EVM PLP-RMS), error vector magnitude (EVM PLP-peak), LDPC iterations, bit error
ratio before LDPC/BCH, BBFrame, TS packet error ratio
Signaling info L1 presignaling info T2 version, transmission system, guard
(L1 presignaling, PLP parameter and interval, pilot pattern, bandwidth
auxiliary L1 post info) extension, number of data symbols per
T2 frame, number of T2 frames per
superframe, PAPR, system ID, cell ID,
network ID, S1 bits, S2 bits, CRC32,
L1 post constellation, L1 post code rate,
L1 post FEC type, L1 post extension,
L1 post size, L1 post info size, L1
repetition, type of TX input streams,
TX ID availability, regeneration flag,
number of frequencies, current RF index,
reserved

3
R&S®ETC-K1 option required.

10 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

PLP parameter info number of PLP, group ID, PLP ID,


PLP type, PLP constellation, PLP rotation,
PLP FEC type, PLP code rate, PLP
payload type, time interleave type, time
interleave length, number of maximum
blocks, PLP mode, static flag, static
padding flag, fixed freq flag, first RF index,
inband signaling A, inband signaling B,
reserved_1, first frame index, frame
interval
auxiliary L1-post info subslices/frame, aux config RFU, FEF
type (binary), FEF length, FEF interval,
RF_IDX, aux streams type, aux streams
private conf(hex)
Constellation diagram QAM order constellation of selected PLP, selectable
number of I/Q cells
Echo pattern level range 50 dB
(channel impulse response) span units µs, km, miles
marker level resolution 0.1 dB
marker type relative level, absolute level
marker functions set to peak, set to next peak,
center = marker
echo pattern peak list 13 highest peaks with relative and
absolute level and time or distance
MER(k) MER range 10/20/50 dB
(modulation error ratio versus OFDM carrier range all modulated OFDM carriers
carriers) marker position units carrier number, relative frequency,
absolute frequency
marker MER resolution 0.1 dB
marker functions set to peak, set to next peak
trace detectors RMS, auto peak, min. peak, max. peak
TV spectrum lower and upper shoulder attenuation in line with ETSI TR 101290
in-channel amplitude frequency response, peak-to-peak
carrier to noise
occupied bandwidth
Spectrum emission mask spectrum emission test against emission mask

Measurement uncertainty
Signal level 95 % confidence level, +20 °C to +30 °C, C/N > 16 dB, RF attenuation = auto
10 MHz to 3.6 GHz < 1 dB, 0.5 dB (typ.)
3.6 GHz to 8 GHz < 1.5 dB, 1 dB (typ.)
Crest factor < 0.5 dB (typ.)
Carrier frequency offset RF × reference uncertainty
Symbol rate offset reference uncertainty
MPEG TS bitrate MPEG TS bit rate × reference uncertainty
Modulation error ratio (MER) RF = 500 MHz, 64QAM, slow channel adaptation
20 dB to 30 dB < 1.0 dB (typ.)
30 dB to 35 dB < 1.5 dB (typ.)
35 dB to 40 dB < 2.0 dB (typ.)
Error vector magnitude (EVM) RF = 500 MHz, 64QAM, slow channel adaptation, referenced to measured value
0.65 % to 1.2 % < 25 %
1.2 % to 2 % < 20 %
2 % to 7 % < 12 %
BER before LDPC or BCH 1.0 × 10–3 to 0.1 × 10–15, 0.0 0.1 × 10–exponent
BB frame error ratio 1.0 × 10–1 to 0.1 × 10–12, 0.0 0.1 × 10–exponent
–1 –12
TS packet error ratio 1.0 × 10 to 0.1 × 10 , 0.0 0.1 × 10–exponent

Rohde & Schwarz R&S®ETC Compact TV Analyzer 11


Version 06.00, November 2017

Amplitude/phase/group delay measurement (R&S®ETC-K180 option)


Amplitude measurement
Magnitude range of display ±5/10/25/50 dB,
100 % linear, selectable
resolution (peak-to-peak value) 0.1 dB
marker level resolution 0.1 dB
marker type carrier number, relative frequency,
absolute frequency
marker functions set to peak, set to next peak
Accuracy RF preselection = off, 5 dB attenuation
< ±0.3 dB (typ.)
Phase measurement
Magnitude range of display ±5/10/25/45/90/180°,
selectable
resolution (peak-to-peak value) 0.1°
marker level resolution 0.1°
marker type carrier number, relative frequency,
absolute frequency
marker functions set to peak, set to next peak
Accuracy RF preselection = off
< ±0.5° (typ.)
Group delay measurement
Magnitude range of display ±25/50/100/250 ns,
±0.5/1.0/2.5/5/10/25/50 µs
selectable
resolution (peak-to-peak value) 0.01 ns/0.01 µs
Note: Unit is autoselected depending on
the measured result.
marker level resolution 0.01 ns/0.01 µs
marker type carrier number, relative frequency,
absolute frequency
marker functions set to peak, set to next peak
Accuracy RF preselection = off
< ±10 ns (typ.)
Amplitude/phase/group delay measurement
Trace detectors RMS, auto peak
Trace functions view, clear/write, average, blank

12 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

MPEG decoder board (R&S®ETC-B280 option, requires at least one digital TV


standard R&S®ETC-K140, R&S®ETC-K160 or R&S®ETC-K240)
Broadcasting standard DVB-T/DVB-H
DVB-T2
ISDB-T
MPEG analysis displayed parameter network ID, video/audio PID, service ID,
video format, video size, video frame rate,
audio format, audio language, audio
sampling rate
Supported video format for decoding MPEG-2, H.264
Supported audio format for decoding MPEG-1, MPEG-2

Rohde & Schwarz R&S®ETC Compact TV Analyzer 13


Version 06.00, November 2017

Spectrum analysis
Frequency
Frequency range model .04 100 kHz to 3.6 GHz
model .08 100 kHz to 8 GHz
Resolution 1 Hz
Reference frequency, internal
Aging per year 1 × 10–6
Temperature drift 0 °C to +30 °C 1 × 10–6
+30 °C to +50 °C 3 × 10–6
Achievable initial calibration accuracy 5 × 10–7
Total reference uncertainty 0 °C to +30 °C (time since last adjustment × aging rate) +
temperature drift + calibration accuracy
Reference frequency, with R&S®HA-Z240 option
Frequency uncertainty GPS on, ≥ 1 minute after satellite lock 2.5 × 10–8
up to 30 minutes after losing satellite lock 5 × 10–8
Frequency readout
Marker resolution 0.1 Hz
Uncertainty ±(marker frequency × reference
uncertainty + 10 % × resolution bandwidth
+ ½ (span / (sweep points – 1)) + 1 Hz)
Number of sweep (trace) points default value 631
Marker tuning frequency step size span/630
Frequency counter resolution 0.1 Hz
Frequency counter uncertainty S/N > 25 dB ±(frequency × reference uncertainty +
½ (last digit))
with R&S®HAZ240 option
GPS on, ≥ 1 minute after satellite lock 2.5 × 10–8
up to 30 minutes after losing satellite 5 × 10–8
lock
Frequency span 0 Hz, 10 Hz to 3.6/8 GHz
Frequency span uncertainty 1 % (nom.)
Spectral purity of SSB phase noise RF = 500 MHz
Carrier offset 30 kHz < –98 dBc (1 Hz), –102 dBc (1 Hz) (typ.)
100 kHz < –100 dBc (1 Hz), –106 dBc (1 Hz) (typ.)
1 MHz < –125 dBc (1 Hz), –131 dBc (1 Hz) (typ.)

Sweep time
Sweep time span = 0 Hz 200 µs to 100 s
10 Hz ≤ span ≤ 600 MHz 20 ms to 1000 s
span > 600 MHz 20 ms × span/600 MHz to 1000 s
Uncertainty span = 0 Hz 1 % (nom.)
span ≥ 10 Hz 3 % (nom.)

Bandwidths
Resolution bandwidths
Range –3 dB bandwidth 100 Hz to 3 MHz in 1, 3 sequence
Bandwidth accuracy 100 Hz ≤ RBW ≤ 300 kHz < 5 % (nom.)
RBW > 300 kHz < 10 % (nom.)
Selectivity 60 dB:3 dB < 5 (nom.) (Gaussian type filters)
Video filters
Range –3 dB bandwidth 10 Hz to 3 MHz in 1, 3 sequence
RF preselection (R&S®ETC-K1 option)
Lower 3 dB cut-off frequency RF up to 80 MHz 500 kHz
80 MHz to 200 MHz RF – 15 MHz
0.2 GHz to 1.5 GHz 0.9 × RF
1.5 GHz to 3.6 GHz 1.3 GHz
3.6 GHz to 8 GHz 3.2 GHz
Upper 3 dB cut-off frequency RF up to 80 MHz 80 MHz
80 MHz to 200 MHz RF + 15 MHz
0.2 GHz to 1.5 GHz 1.1 × RF
1.5 GHz to 3.6 GHz 3.7 GHz
3.6 GHz to 8 GHz 8 GHz

14 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

Level
Display range displayed noise floor to +20 dBm
Maximum rated input level (nominal values)
DC voltage 80 V
RF power 27 dBm (= 0.5 W)
CW RF power 30 dBm (= 1 W)
Peak RF power duration < 3 s 33 dBm (= 2 W)
Max. pulse voltage 100 V
Max. pulse energy pulse width = 10 µs 10 mWs
Intermodulation
Third-order intermodulation (TOI) intermodulation-free dynamic range, signal level 2 × –15 dBm, RF attenuation = 5 dB,
(nominal values) RF preselection = off
50 MHz to 2 GHz 54 dBc (TOI +12 dBm)
2 GHz to 8 GHz 60 dBc (TOI +15 dBm)
intermodulation-free dynamic range, signal level 2 × –30 dBm, RF attenuation = 5 dB,
RF preselection = on 4
50 MHz to 200 MHz 54 dBc (TOI –3 dBm)
200 MHz to 3.6 GHz 60 dBc (TOI 0 dBm)
3.6 GHz to 8 GHz 66 dBc (TOI +3 dBm)
Second-order intermodulation (SOI) signal level 2 × –30 dBm (250.0 MHz and 250.1 MHz), RF attenuation = 5 dB,
(nominal values) RF preselection = off
500 MHz 45 dBm
signal level 2 × –30 dBm (250.0 MHz and 250.1 MHz), RF attenuation = 5 dB,
RF preselection = on 4
500 MHz 55 dBm
Displayed average noise level RF attenuation = 0 dB, termination = 50 Ω, RBW = 1 kHz, VBW = 10 Hz, sample
detector, trace average 10, log scaling, tracking generator off, normalized to 1 Hz
RF preselection = off
100 kHz to 1 MHz < –125 dBm, –129 dBm (typ.)
1 MHz to 10 MHz < –148 dBm, –153 dBm (typ.)
10 MHz to 2.5 GHz < –151 dBm, –157 dBm (typ.)
2.5 GHz to 3 GHz < –148 dBm, –154 dBm (typ.)
3 GHz to 4 GHz < –144 dBm, –150 dBm (typ.)
4 GHz to 7 GHz < –145 dBm, –151 dBm (typ.)
7 GHz to 8 GHz < –133 dBm, –137 dBm (typ.)
RF preselection = on 4
1 MHz to 10 MHz < –154 dBm, –160 dBm (typ.)
10 MHz to 500 MHz < –160 dBm, –165 dBm (typ.)
500 MHz to 3.6 GHz < –158 dBm, –163 dBm (typ.)
3.6 GHz to 7 GHz < –154 dBm, –160 dBm (typ.)
7 GHz to 8 GHz < –146 dBm, –151 dBm (typ.)
Immunity to interference (nominal values)
Image frequencies fin – 2 × 21.4 MHz –63 dBc
fin – 2 × 830.4 MHz –80 dBc
fin – 2 × 4875.4 MHz –90 dBc
Intermediate frequencies 21.4 MHz –60 dBc
830.4 MHz, 4875.4 MHz, 8920.4 MHz –80 dBc
Spurious response, inherent input matched to 50 Ω, without input signal, RBW ≤ 30 kHz, RF attenuation = 0 dB
RF preselection = off < –90 dBm
RF preselection = on 4 < –100 dBm
Other interfering signals signal level – RF attenuation < –30 dBm, RF preselection = off
10.7 MHz –60 dBc
2437.7 MHz –60 dBc
signal level – RF attenuation < –30 dBm, RF preselection = off, RF ≤ 3.6 GHz
spurious at fin – 2437.7 MHz –80 dBc
signal level – RF attenuation < –40 dBm, RF preselection = off, RF ≥ 3.6 GHz
4460.2 MHz –40 dBc

4
R&S®ETC-K1 option required.

Rohde & Schwarz R&S®ETC Compact TV Analyzer 15


Version 06.00, November 2017

Spurious response, related to local fin ≤ 3.6 GHz


oscillators ∆f < 300 kHz –60 dBc
∆f ≥ 300 kHz < –60 dBc
fin > 3.6 GHz
∆f < 300 kHz –54 dBc
∆f ≥ 300 kHz < –54 dBc
Level display
Logarithmic level axis 1/2/5/10/20/50/100/120/150 dB,
10 divisions
Linear level axis 0 % to 100 %, 10 divisions
Number of traces 2
Trace detectors max. peak, min. peak, auto peak, sample,
RMS
Trace functions clear/write, max. hold, min. hold, average,
view
Setting range of reference level –80 dBm to +20 dBm
Units of level axis dBm, dBmV, dBµV, V, W
Level measurement uncertainty
Total measurement uncertainty 95 % confidence level, +20 °C to +30 °C,
S/N > 16 dB, 0 dB to –50 dB below reference level, RF attenuation = auto,
RF preselection = off
10 MHz < f ≤ 3.6 GHz < 1 dB, 0.5 dB (typ.)
3.6 GHz < f ≤ 8 GHz < 1.5 dB, 1 dB (typ.)
Absolute level uncertainty at 100 MHz +20 °C to +30 °C < 0.5 dB
Frequency response (+20 °C to +30 °C) 1 MHz ≤ f ≤ 10 MHz < 1.5 dB (nom.)
10 MHz ≤ f ≤ 3.6 GHz < 1 dB
3.6 GHz < f ≤ 8 GHz < 1.5 dB
Attenuator uncertainty < 0.3 dB
Uncertainty of reference level setting < 0.1 dB (nom.)
Display nonlinearity S/N > 16 dB, 0 dB to –50 dB, < 0.2 dB
logarithmic level display
Bandwidth switching uncertainty reference: RBW = 10 kHz < 0.1 dB (nom.)

Trigger functions
Trigger
Trigger source free run, video, external
External trigger level threshold low → high transition
high → low transition

16 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

Scalar network analysis (R&S®ETC-K10 option)


Frequency range model .04 100 kHz to 3.6 GHz
model .08 100 kHz to 8 GHz
Resolution 1 Hz
Data points 631
Tracking generator output power tracking generator attenuation = 0 dB 0 dBm (nom.)
Tracking generator attenuator 0 dB to 40 dB in 1 dB steps
Transmission measurement
Magnitude range 1/2/5/10/20/50/100/120/150 dB,
100 % linear, selectable
resolution 0.01 dB
Dynamic range for transmission RF attenuation = 10 dB, tracking generator attenuation = 10 dB, RBW = 1 kHz,
measurements RF preselection = off
100 kHz ≤ f < 6 GHz > 70 dB (nom.)
6 GHz ≤ f < 8 GHz > 60 dB (nom.)
Reflection measurement with external R&S®FSH-Z3 or R&S®FSH-Z2 VSWR bridge
Return loss range 1/2/5/10/20/50/100/120/150 dB,
100 % linear, selectable
resolution 0.01 dB
VSWR range 1 to 1.1/1.5/2/6/11/21/71
Reflection coefficient range 1 mρ to 1000 mρ in 1, 2, 5 steps
Directivity of R&S®FSH-Z3 30 MHz to 3 GHz 28 dB
3 GHz to 6 GHz 25 dB
Return loss at R&S®FSH-Z3 test port 50 MHz to 6 GHz 22 dB
Directivity of R&S®FSH-Z2 10 MHz to 1 GHz 30 dB
1 GHz to 3 GHz 25 dB
Return loss at R&S®FSH-Z2 test port 10 MHz to 3 GHz 20 dB

Rohde & Schwarz R&S®ETC Compact TV Analyzer 17


Version 06.00, November 2017

Inputs and outputs


RF input
Impedance 50 Ω
Connector N female
VSWR (nominal values) RF input attenuation ≥ 10 dB
20 MHz < f ≤ 1.5 GHz < 1.5 (typ.)
1.5 GHz < f ≤ 6 GHz < 2 (typ.)
6 GHz < f ≤ 8 GHz < 3 (typ.)
RF input attenuator RF preselection off 0 dB to 40 dB in 5 dB steps
RF preselection on 5 0 dB to 50 dB in 5 dB steps
Tracking generator output (available with R&S®ETC-K10)
Frequency range model .04 100 kHz to 3.6 GHz
model .08 100 kHz to 8 GHz
Connector N female, 50 Ω
VSWR (nominal values) 100 kHz ≤ f ≤ 3 GHz < 1.5 (typ.)
3 MHz ≤ f ≤ 6 GHz < 2 (typ.)
Tracking generator attenuator 0 dB to 40 dB in 1 dB steps
Maximum rated reverse power (tracking generator output)
DC voltage 50 V
CW RF power +20 dBm (= 0.1 W)
Max. pulse voltage 50 V
Max. pulse energy (10 µs) 1 mWs
External reference input, external trigger input
Connector BNC female, 50 Ω
Mode selectable external reference, external trigger
External reference required level 0 dBm
frequency 10 MHz
External trigger threshold low → high transition 2.4 V
high → low transition 0.7 V
TS ASI output available in following TV analyzer measurement modes: measurement list,
constellation diagram, echo pattern, MER(k)
Connector BNC female, 50 Ω
Output impedance 75 Ω
Output level, peak-to-peak on 75 Ω load 0.8 V
Data rate 270 Mbit/s
Accessories interface
Connector 7-contact female (type Binder 712)
Accessories supported see accessories
AUX interface
Connector 7-contact female (type Binder 712)
LAN interface 10/100BASE-T, RJ-45
USB interface rear panel USB device, type B
USB interface front panel USB host, type A
1 PPS input connector BNC female, rear
input impedance high impedance
input level TTL
Headphones front panel 3.5 mm mini jack

5
R&S®ETC-K1 option required.

18 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

General data
Operating languages English, Russian, Spanish, Italian,
Portuguese, Japanese
Remote control
Command set SCPI 1997.0
LAN interface 10/100BASE-T, RJ-45
USB rear panel USB device, type B
Display
Type 14.5 cm (5.7 in) LCD TFT color
Resolution 640 × 480 pixel
Audio
Speaker internal
Mass memory
Mass memory flash memory (internal)
SD card (internal, 8 Gbyte)
USB memory stick (not supplied),
support up to 16 Gbyte (FAT32)
Data storage internal > 256 instrument settings and traces
8 Gbyte SD card or USB memory stick > 40000 instrument settings and traces
Temperature operating temperature range +5 °C to +40 °C
permissible temperature range 0 °C to +50 °C
storage temperature range –40 °C to +70 °C
Climatic loading relative humidity +25 °C/+40 °C at 95 % relative humidity
IEC 60068-2-30
Mechanical resistance
Vibration sinusoidal IEC 60068-2-6
random IEC 60068-2-64
Shock 40 g shock spectrum,
in line with MIL-STD-810E, method 516.4,
procedure 1, IEC 60068-2-27
Power supply
AC power supply input specifications 100 V to 240 V AC, 50 Hz to 60 Hz,
400 Hz, 150 VA
Input current AC 0.9 to 0.3 A
Power consumption 85 VA (typ.), max. 140 VA with all options
Power consumption TV analyzer mode
(based on AC input 230 V, 50 Hz) with ISDB-T 21.2 W
with ISDB-T and 31.3 W
R&S®ETC-B280 option
with DVB-T/DVB-H 22.5 W
with DVB-T/DVB-H and 32.7 W
R&S®ETC-B280 option
with DVB-T2 32.0 W
with DVB-T2 and 42.2 W
R&S®ETC-B280 option
spectrum analyzer mode
15.0 W
with R&S®ETC-B280 option 23.8 W
Safety IEC 61010-1, EN 61010-1, UL 61010-1,
CSA C22.2 No. 61010-1
Test mark VDE, GS, CSA, KC
EMC in line with European EMC Directive
2004/108/EC, including
IEC/EN 61326 class A (emission),
CISPR 11/EN 55011/group 1
class A (emission),
IEC/EN 61326 table A.1
(immunity, industrial)
Dimensions W×H×D 233 mm × 158 mm × 350 mm
(9.2 in × 6.2 in × 13.8 in)
Weight 4.8 kg (10.6 lb)
Recommended calibration interval 1 year

Rohde & Schwarz R&S®ETC Compact TV Analyzer 19


Version 06.00, November 2017

Accessories

R&S®FSH-Z14 directional power sensor


Frequency range 25 MHz to 1 GHz
Power measurement range 30 mW to 300 W
VSWR referenced to 50 Ω < 1.06
Power handling capacity depending on temperature and matching 100 W to 1000 W
Insertion loss < 0.06 dB
Directivity > 30 dB
Average power
Power measurement range CF: ratio of peak envelope power to average power
CW, FM, PM, FSK, GMSK 30 mW to 300 W
other modulated signals 30 mW to 300 W/CF
Measurement uncertainty
25 MHz to 40 MHz sine signal 4.0 % of measured value (0.17 dB)
40 MHz to 1 GHz +18 °C to +28 °C, no zero offset 3.2 % of measured value (0.14 dB)
Zero offset after zeroing ±4 mW
Range of typical measurement error FM, PM, FSK, GMSK 0 % of measured value (0 dB)
with modulation AM (80 %) ±3 % of measured value (±0.13 dB)
2 CW carriers with identical power ±2 % of measured value (±0.09 dB)
Temperature coefficient 25 MHz to 40 MHz 0.40 %/K (0.017 dB/K)
40 MHz to 1 GHz 0.25 %/K (0.011 dB/K)
Max. peak envelope power
Power measurement range
Video bandwidth 4 kHz 0.4 W to 300 W
200 kHz 1 W to 300 W
600 kHz 2 W to 300 W
Measurement uncertainty same as for average power plus effect of +18 °C to +28 °C
peak hold circuit
Error limits of peak hold circuit for burst duty cycle ≥ 0.1 and repetition rate ≥ 100/s
signals video bandwidth = 4 kHz ±(3 % of measured value + 0.05 W)
starting from a burst width of 200 µs
video bandwidth = 200 kHz ±(3 % of measured value + 0.20 W)
starting from a burst width of 4 µs
video bandwidth = 600 kHz ±(7 % of measured value + 0.40 W)
starting from a burst width of 2 µs
20/s ≤ repetition rate < 100/s plus ±(1.6 % of measured value + 0.15 W)
0.001 ≤ duty cycle < 0.1 plus ±0.10 W
Temperature coefficient 25 MHz to 40 MHz 0.50 %/K (0.022 dB/K)
40 MHz to 1 GHz 0.35 %/K (0.015 dB/K)
Load matching
Matching measurement range
Return loss 0 dB to 23 dB
VSWR > 1.15
Minimum forward power specs met from 0.4 W 0.06 W
General data
Dimensions W×H×D 120 mm × 95 mm × 39 mm
(5.9 in × 3.74 in × 1.53 in)
connecting cable length 1.5 m (59 in)
Weight 0.65 kg (1.43 lb)

20 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

6 1000
AVG AVG
AVG –10 °C to +35 °C (max. 10 ms)
800
–10 °C to +35 °C

4
600

Forward power/W
AVG
400 –10 °C to +50 °C
Error limits/dB

200

–2

–4 100
0 5 10 15 20 25 25 100 200 400 600 800 1000
Return loss/dB Frequency/MHz

Error limits for matching measurements. Power handling capacity.

Rohde & Schwarz R&S®ETC Compact TV Analyzer 21


Version 06.00, November 2017

R&S®FSH-Z44 directional power sensor


Frequency range 200 MHz to 4 GHz
Power measurement range 30 mW to 300 W
VSWR referenced to 50 Ω 200 MHz to 3 GHz < 1.07
3 GHz to 4 GHz < 1.12
Power handling capacity depending on temperature and matching 120 W to 1000 W
Insertion loss 200 MHz to 1.5 GHz < 0.06 dB
1.5 GHz to 4 GHz < 0.09 dB
Directivity 200 MHz to 3 GHz > 30 dB
3 GHz to 4 GHz > 26 dB
Average power
Power measurement range CF: ratio of peak envelope power to average power
CW, FM, PM, FSK, GMSK 30 mW to 300 W
other modulated signals 30 mW to 300 W/CF
Measurement uncertainty sine signal, +18 °C to +28 °C, no zero offset
200 MHz to 300 MHz 4.0 % of measured value (0.17 dB)
300 MHz to 4 GHz 3.2 % of measured value (0.14 dB)
Zero offset after zeroing ±4 mW
Range of typical measurement error with FM, PM, FSK, GMSK 0 % of measured value (0 dB)
modulation AM (80 %) ±3 % of measured value (±0.13 dB)
two CW carriers with identical power ±2 % of measured value (±0.09 dB)
π/4-DQPSK ±2 % of measured value (±0.09 dB)
Temperature coefficient 200 MHz to 300 MHz 0.40 %/K (0.017 dB/K)
300 MHz to 4 GHz 0.25 %/K (0.011 dB/K)
Max. peak envelope power
Power measurement range modulated carriers
video bandwidth = 4 kHz 0.4 W to 300 W
video bandwidth = 200 kHz 1 W to 300 W
video bandwidth = 4 MHz 2 W to 300 W
Measurement uncertainty +18 °C to +28 °C same as for average power plus effect of
peak hold circuit
Error limits of peak hold circuit for burst duty cycle ≥ 0.1 and repetition rate ≥ 100/s
signals video bandwidth = 4 kHz ±(3 % of measured value + 0.05 W)
starting from a burst width of 100 µs
video bandwidth = 200 kHz ±(3 % of measured value + 0.20 W)
starting from a burst width of 4 µs
video bandwidth = 4 MHz ±(7 % of measured value + 0.40 W)
starting from a burst width of 1 µs
20/s ≤ repetition rate < 100/s plus ±(1.6 % of measured value + 0.15 W)
0.001 ≤ duty cycle < 0.1 plus ±0.10 W
burst width ≥ 0.5 µs plus ±5 % of measured value
burst width ≥ 0.2 µs plus ±10 % of measured value
Temperature coefficient 200 MHz to 300 MHz 0.50 %/K (0.022 dB/K)
300 MHz to 4 GHz 0.35 %/K (0.015 dB/K)
Load matching
Matching measurement range
Return loss 200 MHz to 3 GHz 0 dB to +23 dB
VSWR 3 GHz to 4 GHz 0 dB to +20 dB
VSWR 200 MHz to 3 GHz > 1.15
3 GHz to 4 GHz > 1.22
Minimum forward power specs met from 0.2 W 0.03 W
General data
Dimensions W×H×D 120 mm × 95 mm × 39 mm
(5.9 in × 3.74 in × 1.53 in)
connecting cable length 1.5 m (59 in)
Weight 0.65 kg (1.43 lb)

22 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

6
1000

800
4 AVG –10 °C to +35 °C

600

Forward power/W
Measurement error/dB

AVG –10 °C to +35 °C

2
400

0.2 GHz to 3 GHz


0 3 GHz to 4 GHz AVG +35 °C to +50 °C

200
–2

–4 100
0 5 10 15 20 25 0.2 0.4 0.7 1 2 3 4
Return loss/dB Frequency/GHz

Error limits for matching measurements. Power handling capacity.

Rohde & Schwarz R&S®ETC Compact TV Analyzer 23


Version 06.00, November 2017

R&S®HA-Z240 GPS receiver


GPS location indication latitude, longitude
Frequency counter uncertainty GPS on, ≥ 1 minute after satellite lock 2.5 × 10–8
up to 30 minutes after losing satellite lock 5 × 10–8
Operating temperature range –20 °C to +55 °C
Storage temperature range –40 °C to +70 °C
Climatic loading GPS receiver module IEC 60529 IPX7 level
Dimensions ø×H 61 mm × 19.5 mm (2.4 in × 0.8 in)
Weight 200 g (0.4 lb)
Cable length 5 m (16.4 ft)
Connector 7-contact male (type Binder 712)
Power consumption 0.45 W
Test marks FCC, CE

24 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

Ordering information
Designation Type Order No.
Base unit
Compact TV Analyzer, up to 3.6 GHz R&S®ETC 2116.5000.04
Compact TV Analyzer, up to 8 GHz R&S®ETC 2116.5000.08
Accessories supplied
USB cable, quick reference guide and CD-ROM with R&S®ETCView PC software and documentation
Hardware option
FPGA Extension Board R&S®ETC-B300 2116.5230.02
MPEG Decoder Board (requires at least one digital TV standard R&S®ETC-B280 2116.5252.02
R&S®ETC-K140, R&S®ETC-K160 or R&S®ETC-K240)
Software options
RF Preselection, up to 3.6 GHz R&S®ETC-K1 2116.5098.02
RF Preselection, up to 8 GHz R&S®ETC-K1 2116.5181.02
Tracking Generator with Scalar Network Analysis, up to 3.6 GHz R&S®ETC-K10 2116.5169.02
Tracking Generator with Scalar Network Analysis, up to 8 GHz R&S®ETC-K10 2116.5175.02
Phase and Group Delay Measurement R&S®ETC-K180 2116.5130.02
(requires at least one TV standard)
DVB-T/DVB-H Analysis R&S®ETC-K140 2116.5100.02
ISDB-T Analysis R&S®ETC-K160 2116.5117.02
DVB-T2 Analysis (requires R&S®ETC-B300) R&S®ETC-K240 2116.5123.02
Software application tools for DVB-T2, DVB-T and ISDB-T
Broadcast Drive Test R&S®ETC-K930 2116.5146.02
Automatic Transmitter Measurement, TXCheck R&S®ETC-K940 2116.5152.02
External accessories
GPS Receiver R&S®HA-Z240 1309.6700.03
Directional Power Sensor, 25 MHz to 1 GHz R&S®FSH-Z14 1120.6001.02
Directional Power Sensor, 200 MHz to 4 GHz R&S®FSH-Z44 1165.2305.02
Wideband Power Sensor, 50 MHz to 18 GHz, 100 mW R&S®NRP-Z81 1137.9009.02
Soft Carrying Bag R&S®RTM-Z3 1305.0289.02
R&S®ETC Hard Case R&S®ETC-Z1 2116.5300.00

Warranty
Base unit 3 years
All other items 1 year
Options
Extended Warranty, one year R&S®WE1 Please contact your local
Extended Warranty, two years R&S®WE2 Rohde & Schwarz sales office.
Extended Warranty with Calibration Coverage, one year R&S®CW1
Extended Warranty with Calibration Coverage, two years R&S®CW2

Extended warranty with a term of one and two years (WE1 and WE2)
Repairs carried out during the contract term are free of charge 6. Necessary calibration and adjustments carried out during repairs are
also covered.

Extended warranty with calibration coverage (CW1 and CW2)


Enhance your extended warranty by adding calibration coverage at a package price. This package ensures that your
Rohde & Schwarz product is regularly calibrated, inspected and maintained during the term of the contract. It includes all repairs 6 and
calibration at the recommended intervals as well as any calibration carried out during repairs or option upgrades.

For product brochure, see PD 3606.6970.12 and www.rohde-schwarz.com

6
Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included.

Rohde & Schwarz R&S®ETC Compact TV Analyzer 25


Version 06.00, November 2017

26 Rohde & Schwarz R&S®ETC Compact TV Analyzer


Version 06.00, November 2017

Rohde & Schwarz R&S®ETC Compact TV Analyzer 27


About Rohde & Schwarz
Service that adds value The Rohde & Schwarz electronics group offers innovative
❙ Worldwide solutions in the following business fields: test and mea-
❙ Local and personalized surement, broadcast and media, secure communications,
❙ Customized and flexible
cybersecurity, radiomonitoring and radiolocation. Founded
❙ Uncompromising quality
❙ Long-term dependability
more than 80 years ago, this independent company has
an extensive sales and service network and is present in
more than 70 countries. The electronics group is among
the world market leaders in its established business fields.
The company is headquartered in Munich, Germany. It
also has regional headquarters in Singapore and Columbia,
Maryland, USA, to manage its operations in these regions.

Sustainable product design


❙❙ Environmental compatibility and eco-footprint
❙❙ Energy efficiency and low emissions
❙❙ Longevity and optimized total cost of ownership

Certified Quality Management Certified Environmental Management

ISO 9001 ISO 14001

Rohde & Schwarz GmbH & Co. KG


www.rohde-schwarz.com

Rohde & Schwarz training


www.training.rohde-schwarz.com

Regional contact
❙❙ Europe, Africa, Middle East | +49 89 4129 12345
customersupport@rohde-schwarz.com
❙❙ North America | 1 888 TEST RSA (1 888 837 87 72)
customer.support@rsa.rohde-schwarz.com
❙❙ Latin America | +1 410 910 79 88
customersupport.la@rohde-schwarz.com
❙❙ Asia Pacific | +65 65 13 04 88
customersupport.asia@rohde-schwarz.com
❙❙ China | +86 800 810 82 28 | +86 400 650 58 96
customersupport.china@rohde-schwarz.com

R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG


3606.6970.22 06.00 PDP 1 en

Trade names are trademarks of the owners


PD 3606.6970.22 | Version 06.00 | November 2017 (fi)
R&S®ETC Compact TV Analyzer
Data without tolerance limits is not binding | Subject to change
© 2012 - 2017 Rohde & Schwarz GmbH & Co. KG | 81671 Munich, Germany

3606697022

ETC_dat-sw_en_3606-6970-22_v0600_cover.indd 2 02.11.2017 14:55:07