DATA SHEETS
ITEM No. ATT ITEM No. ATT ITEM No. ATT
PUMP
MOTOR
GEAR
TURBINE
APPLICABLE OVERLAY STANDARDS
181
Figure N.1⎯API Std 610 CENTRIFUGAL PUMP DATA SHEET (SI Units) (continued)
6 LIQUID CHARACTERISTICS
7 Units Maximum Minimum Note SERVICE :
8 LIQUID TYPE OR NAME : Max & min values refer • IF INTERMITTENT NO. OF STARTS :
9 VAPOR PRESSURE : kPa only to the property PUMPS OPERATE IN:
10 RELATIVE DENSITY : listed CORROSION DUE TO : (6.12.1.9)
11 SPECIFIC HEAT : kJ/(kg-K) EROSION DUE TO : (6.12.1.9)
12 VISCOSITY : Pa s H2S CONCENTRATION (ppm) : (6.12.1.12)
16 PUMPING TEMPERATURE : °K
17 FLOW : m³/s
18 DISCHARGE PRESSURE : (6.3.2) kPa
19 SUCTION PRESSURE : kPa
20 DIFFERENTIAL PRESSURE : kPa
21 DIFFERENTIAL HEAD : m
22 NPSHA : m
23 HYDRAULIC POWER : kW
35 Min
36 UTILITY CONDITIONS : PRESS. kPa Max
37 ELECTRICITY : DRIVERS HEATING CONTROL SHUTDOWN Min
38 VOLTAGE
39 PHASE
40 HERTZ
182
Figure N.1⎯API Std 610 CENTRIFUGAL PUMP DATA SHEET (SI Units) (continued)
183
Figure N.1⎯API Std 610 CENTRIFUGAL PUMP DATA SHEET (SI Units) (continued)
9 Mounting Location of Accelerometers SEE ATTACHED ISO 21049/API 682 DATA SHEET
10 ADDITIONAL CENTRAL FLUSH PORT (6.8.9)
11 FLAT SURFACE REQUIRED (6.10.2.11) HEATING JACKET REQ'D. (6.8.11)
12 Number of Accelerometers
13 Mounting Location of Accelerometers HEATING AND COOLING (6.1.17)
14 COOLING REQ'D
15 VIBRATION PROBES (7.4.2.2) COOLING WATER PIPING PLAN
16 PROVISIONS FOR VIB. PROBES COOLING WATER PIPING
17 NUMBER PER RADIAL BEARING FITTINGS
18 NUMBER PER AXIAL BEARING COOLING WATER PIPING MATERIALS
COOLING WATER REQUIREMENTS:
19 MONITORS AND CABLES SUPPLIED BY (7.4.2.4) BEARING HOUSING m³/s
20 HEAT EXCHANGER m³/s
21 TEMPERATURE (7.4.2.3) TOTAL COOLING WATER m³/s
22 PROVISIONS FOR TEMP PROBES HEATING MEDIUM
23 RADIAL BEARING TEMP. OTHER
24 NUMBER PER RADIAL BEARING HEATING PIPING
25 THRUST BEARING TEMP.
26 NUMBER PER THRUST BEARING ACTIVE SIDE PIPING & APPURTENANCES
27 NUMBER PER THRUST BEARING INACTIVE SIDE MANIFOLD PIPING FOR PURCHASER CONNECTION (7.5.1.6)
28 TEMP. GAUGES (WITH THERMOWELLS) (9.1.3.6) VENT
29 PRESSURE GAUGE TYPE DRAIN
30 Remarks COOLING WATER
31 TAG ALL ORIFICES (7.5.2.4)
32 SOCKET WELD CONN ON SEAL GLAND (7.5.2.8)
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
184
Figure N.1⎯API Std 610 CENTRIFUGAL PUMP DATA SHEET (SI Units) (continued)
185
Figure N.1⎯API Std 610 VERTICAL PUMP SUPPLEMENTAL DATA SHEET (SI Units) (continued)
29 MATERIALS (additional)
30 SUCTION CAN / BARREL: LINESHAFT SLEEVES :
31 DISCHARGE HEAD • BEARING RETAINER :
32 BOWL SHAFT : SHAFT ENCLOSING TUBE :
33 LINESHAFT : DISCHARGE COLUMN :
34 LINESHAFT HARDFACING : PRESSURE RATING: MAWP HYDRO
35 BELLMOUTH : HEAD
36 BOWL BEARING : COLUMN PIPE
37 LINESHAFT BEARING : BOWL
38 SUMP ARRANGEMENT
39 SUMP DIMENSIONS :
40 GRADE ELEVATION 1 m
41 LOW LIQUID LEVEL 2 m 1 2 3
42 C.L. OF DISCHARGE 3 m
43 SUMP DEPTH l1 m
l3
44 PUMP LENGTH l2 m
45 GRADE TO DISCH. l3 m
46 GRADE TO LOW LIQUID LVL l4 m
l4
48 SUBMERGENCE REQ'D l6 m
l1
49 SUMP DIAMETER Φd m
l6
50
51
52
53 Φd
54
55
56
57
186
Figure N.1⎯API Std 610 CENTRIFUGAL PUMP DATA SHEET (SI Units) (continued)
7 THESE REFERENCES MUST BE LISTED BY THE PURCHASER. (DEFAULT TO TABLE 10 IF NO PURCHASER PREFERENCE IS STATED)
8 ALTERNATE WELDING CODES AND STANDARDS
9 WELDING REQUIREMENT (APPLICABLE CODE OR STANDARD)
10 WELDER/OPERATOR QUALIFICATION
11 WELDING PROCEDURE QUALIFICATION
12 NON-PRESSURE RETAINING STRUCTURAL WELDING SUCH AS BASEPLATES OR SUPPORTS
13 MAGNETIC PARTICLE OR LIQUID PENETRANT EXAMINATION OF PLATE EDGES
14 POSTWELD HEAT TREATMENT
15 POSTWELD HEAT TREATMENT OF CASING FABRICATION WELDS
16
17 MATERIAL INSPECTION
20 RADIOGRAPHY
21 ULTRASONIC INSPECTION
22 MAGNETIC PARTICLE INSPECTION
23 LIQUID PENETRANT INSPECTION
24 VISUAL INSPECTION (all surfaces)
25
26 REMARKS :
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
187
Figure N.3⎯CENTRIFUGAL PUMP DATA SHEET
7 CONTINUOUS, INTERMITTENT
8
9 PARALLEL, SERIES
10
11
12
28 6.1.22 0, 1, 2, SAFE
29 Group Temp Class
30 CLASS I/GROUP A T1 T3B
31 CLASS I/GROUP B T2 T3C
32 CLASS I/GROUP C T2A T4
33 CLASS I/GROUP D T2B T4A
34 MINING T2C T5
35 CLASS II/GROUP E Conditions T2D T6
36 CLASS II/GROUP F DUST T3
37 CLASS II/GROUP G FUMES T3A
38 CLASS III DUST & FUMES T3B
39 OTHER T3C
40
59
60
61
195
Figure N.3⎯CENTRIFUGAL PUMP DATA SHEET (continued)
4 6.5.5 Facing Rating Position 6.3.10 SINGLE VOLUTE, MULTIPLE VOLUTE, DIFFUSER
5 FF 150 END 9.1.2.6 YES, NO
6 RF 300 TOP
7 RTJ 600 SIDE
8 900 IN-LINE
9 1500 BOTTOM YES, NO
10 BELL YES, NO
11 6.4.3.2 Type Facing Rating Position CCW, CW
12 SW FF 125 TOP YES, NOT, BOTH DIRECTIONS
150
13 SWF RF 250 SIDE YES, NO
14 RTJ 300 IN-LINE YES, NO
15 600
900
16 1500
17 SUPPLIER, PURCHASER 9.1.1.3 YES, NO, N/A
18 YES, NO YES, NO, N/A
19 SUPPLIER, PURCHASER 9.2.2.3 YES, NO, N/A
20 YES, NO
21 6.4.3.2 YES, NO
22 6.4.3.3 YES, NO
23 6.4.3.8 YES, NO
24 YES, NO
25 6.4.3.12 YES, NO
26 INTERNAL, EXTERNAL, N/A
27 YES, NO YES, NO N/A
28 7.2.10 YES, NO N/A
29 MATERIAL (6.12.1.1) 7.2.3 YES, NO N/A
30 I-1, I-2, S-1, S-2, S-3, S-4, S-5, S-6, S-7, S-8, S-9, C-6, A-7, A-8, D-1
31 7.2.11 YES, NO, N/A
32 6.12.1.12.1 YES, NO 7.2.4 ISO 14691, ISO 10441, API 671, API 610 COMPLIANT, MFR STD
33 6.12.1.12.3 NA, ISO 15156, MR0103, MR0175 7.2.13.A ISO 14120, EN 953, ANSI B16.1
34 YES, NO, N/A
35
36 BASEPLATE
37 0.5, 1, 1.5, 2, 3, 3.5, 4, 5, 5.5, 6, 6.5, 7, 7.5, 8, 9, 9.5, 10, 11, 11.5, 12, N/A
7.3.14 OPEN BEAM SUPPORT, FULL TOP DECKING,
38 PARTIAL TOP DECKING, OPEN DECKING
7.3.1 ENTIRE BASEPLATE DRAIN RIM, ENTIRE BASEPLATE DRAIN PAN,
39 PARTIAL DRAIN PAN
GROUTED, BOLTED ON STEEL WORK, THREE POINT MOUNT, FOUR
40 POINT MOUNT, STILT MOUNTED
50 2, 3 (9.2.6.5) YES, NO
50
51 YES, NO
52
53
54 PURCHASER, SUPPLIER
55
56
57 REQUIRED, NOT REQUIRED
196
Figure N.3⎯CENTRIFUGAL PUMP DATA SHEET (continued)
27
28 9.1.3.6 YES, NO, N/A YES, NO, N/A
29 YES, NO, N/A
30 YES, NO, N/A
31 7.5.2.4 YES, NO, N/A
32 7.5.2.8 YES, NO, N/A
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
197
Figure N.3⎯CENTRIFUGAL PUMP DATA SHEET (continued)
28
29 8.1.1.C, 8.3.3.5 YES, NO
30 7.3.21 YES, NO
31 NON-WIT, WIT, OBSERVE
32 9.3.13.2 NON-WIT, WIT, OBSERVE
33 OTHER PURCHASER REQUIREMENTS NON-WIT, WIT, OBSERVE
34 10.1.3 YES, NO 8.3.3.2 8.3.3.2, MFR STD
35 8.3.3.3 8.3.3.3, MFR STD
36 YES, NO 8.3.3.4 TABLE 15, AGREED LIMITS
37 YES, NO 8.3.4.3.1, 8.3.4.3.4 NON-WIT, WIT, OBSERVE
38 YES, NO 8.3.4.3.2 NON-WIT, WIT, OBSERVE
39 9.2.1.4 YES, NO 8.3.4.3.3 NON-WIT, WIT, OBSERVE
40 6.9.2.10 YES, NO 8.3.3.6 YES, NO
41 YES, NO 8.3.3.2.D NON-WIT, WIT, OBSERVE
42 10.2.5 YES, NO 8.3.3.7.B NON-WIT, WIT, OBSERVE
43 8.2.1.1 8.3.4.4.1 NON-WIT, WIT, OBSERVE
44 YES, NO 8.3.4.5 NON-WIT, WIT, OBSERVE
45 9.1.3.4, 9.2.4.1.3 YES, NO 8.2.2.6 NON-WIT, WIT, OBSERVE
46 9.3.9.2 YES, NO @ SUPPLIER'S, @ SUB-SUPPLIER'S
47 6.9.4.4 YES, NO NON-WIT, WIT, OBSERVE
48 10.2.3.I YES, NO NON-WIT, WIT, OBSERVE
49 NON-WIT, WIT, OBSERVE
50 6.9.2.3 YES, NO 8.3.4.2.1 NON-WIT, WIT, OBSERVE
51 6.9.2.4 YES, NO 8.3.4.2.2 NON-WIT, WIT, OBSERVE
52 6.10.1.6 YES, NO
7.2.13.e YES, NO 8.3.4.7 NON-WIT, WIT, OBSERVE
53 10.3.2.3 YES, NO 9.3.9.2 NON-WIT, WIT, OBSERVE
54 7.5.2.8 YES, NO
55 6.9.3.3 YES, NO 9.2.7.5 NON-WIT, WIT, OBSERVE
56 7.5.1.7 PTFE COATED, ASTM 153 GAVVANIZED, PAINTED, SS 8.3.4.6 NON-WIT, WIT, OBSERVE
57 YES, NO
58 8.2.1.1.C YES, NO
59 8.3.11 YES, NO
60 8.1.5 YES, NO
61 6.12.4.3 NON-WIT, WIT, OBSERVE
62 NON-WIT, WIT, OBSERVE
NON-WIT, WIT, OBSERVE
198
Figure N.3⎯VERTICAL PUMP SUPPLEMENTAL DATA SHEET (continued)
29 MATERIALS (additional)
30
31 CAST, FABRICATED
32
33
34
35
36
37
38 SUMP ARRANGEMENT
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
199
Figure N.3⎯CENTRIFUGAL PUMP DATA SHEET (continued)
7
8 YES, NO
9 PURCHASER DEFINED, DEFFINED, DEFAULT PER TABLE 10
10
11
12
13
14
15
16
17 MATERIAL INSPECTION
18 YES, NO
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
200