EG4 6000XP System Wiring Diagrams

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

EG4 6000XP SYSTEM WIRING DIAGRAMS

TABLE OF CONTENTS

1. 6000XP - Off-Grid
1a. 6000XP - Off-Grid (with Notes)
2. 6000XP - Partial Home Backup with Grid Input
2a. 6000XP Partial Home Backup with Grid Input (with Notes)
3. 3 6000XPs - Whole Home Backup with No Grid Input
3a. 3 6000XPs Whole Home Backup with No Grid Input (with Notes)
4. 3 6000XPs - Whole Home Backup with Grid Input by Service Entrance Panel (Option 1)
4a. 3 6000XPs - Whole Home Backup with Grid Input by Service Entrance Panel (Option 1) (with Notes)
5. 3 6000XPs - Whole Home Backup with Grid Input by Service Entrance Panel (Option 2)
5a. 3 6000XPs - Whole Home Backup with Grid Input by Service Entrance Panel with Notes (Option 2)
6. 3 6000XPs - Whole Home Backup with Grid Input by Supply-Side Tap
6a. 3 6000XPs Whole Home Backup with Grid Input by Supply-Side Tap (with Notes)
7. 3 6000XPs - Whole Home Backup with Grid Input by Feeder Tap
7a. 3 6000XPs Whole Home Backup with Grid Input by Feeder Tap (with Notes)

DRAWING SET #6000XP-V1-1L, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
1. 6000XP - Off-Grid

PV Panel EG4 6000XP Inverter 2023 NEC 690.12(C)


Strings RSD/ESS 2023 NEC 706.15
See MPPT LOAD GRID GEN PV Disconnect
Wiring
Battery For supported EG4
Comm Initiator Batteries, RSD also
Diagrams Port
IMO BG10P34-11
& EG4 Gen initiates ESS Disconnect
String 2-Wire RSD BAT+ BAT- or equivalent
Start/Stop
Sizer Bond Neutral
Locate near outdoor to Ground here
PV Isolator/ G N service entrance for and only here
Disconnect access by utility &
first responders
IMO SI-Series L1 L2
or equiv.
Locate near outdoor service
2023 NEC 690.15 entrance for access by utility PV
and first responders. System
Fused N 40-70 G
Alternatively, the Generator can 2023 NEC
feed the Grid port in order to free 690.13 Disconnect
EG4 50 Amps Max
40-70 A
the Gen port for Smart Loads or
Batteries AC Coupling. OR OR
Eaton
AC DG222NRB
2-Wire Start/Stop Generator Smart DG223NRB
20-50A Load (EV) Coupled or equiv.
See Battery
Wiring Diagrams Inverter(s) Main Breaker Panel

DRAWING #6000XP-V1-1L-1, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
1a. 6000XP - Off-Grid (with Notes)

PV Panel EG4 6000XP Inverter 2023 NEC 690.12(C)


Strings See MPPT RSD/ESS 2023 NEC 706.15
Wiring Battery LOAD GRID GEN PV Disconnect For supported EG4
Comm Initiator Batteries, RSD also
Diagrams Port
& EG4 Gen
IMO BG10P34-11 initiates ESS Disconnect
String 2-Wire RSD BAT+ BAT- or equivalent
Start/Stop
Sizer Bond Neutral
Locate near outdoor to Ground here
PV Isolator/ and only here
G N service entrance for
Disconnect access by utility &
IMO SI-Series first responders
or equiv. L1 L2
2 poles/string Locate near outdoor service
2023 NEC 690.15 entrance for access by utility PV
and first responders.
System
Fused N 40-70 G
Alternatively, the Generator can 2023 NEC
EG4 feed the Grid port in order to free 50 Amps Max 690.13 Disconnect
the Gen port for Smart Loads or 40-70 A
Batteries AC Coupling. OR OR
Eaton
AC DG222NRB
2-Wire Start/Stop Generator Smart DG223NRB
See Battery 20-50A Load (EV) Coupled or equiv.
Wiring Diagrams Inverter(s) Main Breaker Panel

In Off-Grid single inverter installations with no grid input or generator present, the output
circuit can be sized to 25 Amps x 1.25 = 31.25 A per inverter. Hence switchgear and
overcurrent protection should be sized to 40 Amps.

For Off-Grid installations with a Generator or AC Coupled input, up to 50 Amps can be


provided per inverter and passed through to the Loads. In these cases, a 40-70 Amp input
and output circuit can be utilized (50 x 1.25 = 62.5 Amps per inverter - next sized breaker =
70 A) depending on how much amperage is available to pass through. A 70 Amp breaker will
allow the full 50 Amps to pass through, a 60 Amp breaker will allow 48 Amps of
REC. MIN. BATTERY CAPACITY PER INVERTER > 200AH pass-through.

DRAWING #6000XP-V1-1L-1N, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
2. 6000XP - Partial Home Backup with Grid Input

Locate near outdoor Utility Meter


PV Panel service entrance for
Strings EG4 6000XP Inverter access by utility and
See MPPT first responders.
Wiring Battery LOAD GRID GEN PV
Diagrams Comm 2023 NEC 2023 NEC
& EG4
Port 690.12(C) 706.15
Gen
String 2-Wire RSD BAT+ BAT- RSD/ESS
Sizer Start/Stop
Disconnect N L1 L2
PV Isolator/ Initiator
Disconnect G N IMO
IMO SI-Series BG10P34-11
or equiv. or equivalent 200
2 poles/string Locate near outdoor service G
2023 NEC 690.15 entrance for access by utility 40-70
and first responders.
50 Amps Max L1 L2 Only the Critical
Loads Subpanel is
EG4 backed up in this
Batteries
OR OR configuration.
AC N 40-70 G Main BreakerPanel
2-Wire Generator Smart
Start/Stop
20-50A Load (EV) Coupled Bond Neutral
See Battery Inverter(s) to Ground here
Wiring Diagrams and only here

Critical Loads SubPanel

DRAWING #6000XP-V1-1L-2, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
2a. 6000XP - Partial Home Backup with Grid Input (with Notes)
Locate near outdoor Utility Meter IMPORTANT NOTE: The EG4
PV Panel service entrance for 6000xp inverter is not
Strings See MPPT EG4 6000XP Inverter access by utility and
first responders. capable of providing
Wiring Battery LOAD GRID GEN PV sell-back power to the utility.
Diagrams Comm 2023 NEC 2023 NEC
& EG4
Port 690.12(C) 706.15 It is only a backup or off-grid
String
Gen
2-Wire RSD BAT+ BAT- inverter with the capability
Sizer Start/Stop RSD/ESS of grid INPUT for charging
Disconnect N L1 L2 batteries or passing through
PV Isolator/ Initiator
grid power through the load
Disconnect G N IMO port to a critical loads
IMO SI-Series BG10P34-11 subpanel or transfer switch.
or equiv. or equivalent 100-200 It is essentially a battery
2 poles/string Locate near outdoor service G
entrance for access by utility charger. Therefore it is not
2023 NEC 690.15 and first responders.
40-70 regulated by the NEC 705
Only the Critical
(2023) Interconnection code.
50 Amps Max L1 L2 Loads Subpanel is
EG4 2-Wire backed up in this
Batteries Start/Stop OR OR configuration.
AC N 40-70 G Main BreakerPanel
Generator Smart
20-50A Load (EV) Coupled Bond Neutral
See Battery Inverter(s) to Ground here
Wiring Diagrams and only here

Critical Loads SubPanel


For installations with AC inputs including Grid,
Generator and/or AC Coupling, up to 50 Amps
can be provided per inverter and passed
through to the Loads. In these cases, a 40-70
Amp AC input and output circuit can be utilized
depending on how much amperage is available
(50 x 1.25 = 62.5 Amps per inverter - next sized
breaker = 70 A). A 70 Amp breaker on both the
grid panel and the backed-up loads subpanel
will allow the full 50 Amps to be utilized by the
subpanel. 60 Amp breakers will allow for 48
Amps of pass-through power.
REC. MIN. BATTERY CAPACITY PER INVERTER > 200AH

DRAWING #6000XP-V1-1L-2N, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
3. 3 6000XPs - Whole Home Backup with No Grid Input

Utility Meter
PV Panel 2023 NEC 690.12(C) 2023 NEC 706.15
EG4 6000XP Inverter
Strings See MPPT LOAD GRID GEN PV
Wiring Battery
Comm RSD/ESS
Diagrams Port
Gen Disconnect
& EG4 2-Wire RSD BAT+ BAT- Initiator
Start/Stop
String Sizer
IMO
G N BG10P34-11
2023 NEC 690.15 or equiv 200A
PV Isolator/ Main
Generator > Grid Port Option Locate near outdoor
Disconnect service entrance for access Service
EG4 6000XP Inverter
IMO SI-Series by utility & first responders. Breaker Bond Neutral
or equiv. Battery
Comm CT
LOAD GRID GEN PV Square D to Ground here
2 poles/string Port
Port
PV System QOM2200VH and only here.
Gen
BAT+ BAT- or equiv.
2-Wire
Start/Stop
RSD
Disconnect 2023 NEC
100A 690.13 G N
G N (Eaton
EG4 DG224URK
Batteries or equiv.)
Generator > Grid Port Option Manual
EG4 6000XP Inverter Transfer On
N L1 L2 G
Battery LOAD GRID GEN PV Switch Off
See Battery Comm
Port
CT
Port 200 A On
Wiring Gen
BAT+ BAT- 100 A
Diagrams
2-Wire
Start/Stop
RSD
GE TC10324
or equiv.
Locate near 40
G N 40
outdoor
service 40 L1 L2
entrance for
2-Wire
Generator > Grid Port Option
access by
utility and first Start/Stop Dedicated
responders. OR N L1 L2 G Inverter Output
OR 200
Combiner Panel N G
Smart AC Do not add
Generator 40-125
Load (EV) Coupled additional loads
30-125 A to Dedicated
Inverter(s) 60 Combiner Panels
Do not add 60
additional loads 60
to Dedicated
Combiner Panels Main Breaker Panel
Dedicated Generator,
Smart Load, or AC-Coupled
Combiner Panel

DRAWING #6000XP-V1-1L-3, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
3a. 3 6000XPs - Whole Home Backup with No Grid Input (with Notes)
Utility Meter Whole home backup can be achieved
2023 NEC 690.12(C) 2023 NEC 706.15 with multiple inverters. Since each
PV Panel EG4 6000XP Inverter inverter can supply 25 Amps continuous
Strings See MPPT LOAD GRID GEN PV of backup power and can pass-through
Wiring
Battery
RSD/ESS
Comm
50 Amps of AC input power (either from
Diagrams
Port
Disconnect
Gen
BAT+ BAT- a Generator or AC Coupled Solar in the
& EG4 2-Wire RSD
Initiator
String Sizer
Start/Stop
no grid-input case) 3-6 inverter setups
IMO can provide the majority of what most
G N BG10P34-11 homes need on a continuous basis. To
2023 NEC 690.15 or equiv 200A match the full output of a 200 Amp
PV Isolator/ Main utility service (160 A continuous) you
Generator > Grid Port Option Locate near outdoor
Disconnect service entrance for access Service would need 6 inverters (you would be at
EG4 6000XP Inverter 150 Amps). Most homes don’t draw
IMO SI-Series by utility & first responders. Breaker
or equiv. Battery
Comm CT
LOAD GRID GEN PV Square D anywhere near the 160 amps available
2 poles/string Port
Port
PV System 2023 NEC QOM2200VH from the utility and function usually in
Gen
2-Wire RSD BAT+ BAT-
Disconnect 690.13 or equiv. the 80-120 Amp range hence 4 or 5
inverters will cover most homes. A load
Start/Stop

100A Bond N to G N
assessment is called for when trying to
G N (Eaton G here and achieve whole home backup.
DG224URK only here.
EG4
or equiv.)
Batteries Generator > Grid Port Option Manual
EG4 6000XP Inverter
N L1 L2 G Transfer OnFor systems with no grid input but
Battery
CT
LOAD GRID GEN PV Switch including a transfer switch to energize
Off
See Battery the Main Breaker Panel, the size of the
Comm

200 A
Port
Port
On
Wiring Gen
2-Wire RSD BAT+ BAT- 100 A output circuit must match the # of
Diagrams
Start/Stop
GE TC10324 inverters and the needed generator
40 or equiv. pass-through power. For 3 inverters
Locate near G N
outdoor 40 the total output is 75 amps
service 40 L1 L2 continuous, so a 100 Amp circuit
entrance for 2-Wire
Generator > Grid Port Option would suffice. However if you have a
access by Start/Stop larger than 80 Amp Generator, then a
utility and first Dedicated larger circuit with the corresponding
OR N L1 L2 G
responders. OR Inverter Output 200 breakers would be needed to allow
Combiner Panel N G the full pass-through of the generator.
Smart AC Do not add For choosing breakers for individual
Generator 40-150
Load (EV) Coupled additional loads inverters a 40 A Breaker will allow for
30-125 A to Dedicated
Inverter(s) 50 full inverter output but a 70 A breaker
Combiner Panels is needed for full 50 Amp
50
Distribution Breakers for the dedicated Gen Port pass-through (50 x 1.25 = 62.5 Amps
50 per inverter - next sized breaker = 70
Combiner Panel should be sized to distribute Do not add
total Input amperage evenly up to 50 Amp per additional Main Breaker Panel A). Alternately a 60 Amp breaker will
inverter. For example if you have a 60 Amp loads to Dedicated Generator, allow 48 Amps of pass-through.
rated Generator then the main breaker would Dedicated Smart Load, or AC-Coupled
be 80 A and each inverter breaker would be 30 Combiner. Combiner Panel
Amps for 3 inverters (20A x 1.25 & next size).

DRAWING #6000XP-V1-1L-3N, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
4. 3 6000XPs - Whole Home Backup with Grid Input by Service Entrance Panel (Option 1)

PV Panel EG4 6000XP Inverter 2023 NEC 690.12(C) 2023 NEC 706.15
Strings See MPPT Battery LOAD GRID GEN PV
Wiring Comm
Port
RSD/ESS
Diagrams Gen Disconnect
BAT+ BAT- Service Entrance Panel
& EG4 2-Wire
Start/Stop
RSD
Initiator
String Sizer IMO
G N BG10P34-11
2023 NEC 690.15 or equiv 200
PV Isolator/
60
Disconnect
EG4 6000XP Inverter
IMO SI-Series 60
or equiv. Battery
CT
LOAD GRID GEN PV Utility
2 poles/string
Comm
Port
Port 60 Meter
Gen
2-Wire RSD BAT+ BAT-
Start/Stop

G N
G N Locate near
EG4 outdoor service
Batteries entrance for Manual
EG4 6000XP Inverter access by utility & Transfer On
first responders. Off
Battery
Comm CT
LOAD GRID GEN PV Switch
Port
Port
200 A On
See Battery Gen
2-Wire RSD BAT+ BAT-
Wiring
Start/Stop
GE TC10324
Diagrams PV System or equiv.
G N Disconnect
Locate near 2023 NEC 690.13
outdoor 80-200A
service (Eaton
DG224URK L1 L2
entrance for
access by 2-Wire Start/Stop or equiv.)
utility and first
responders.
OR N L1 L2 G 200
OR N G
N L1 L2 G
Smart AC
Generator 30-150
Load (EV) Coupled
30-125A 200
Inverter(s) 50
50 70
Do not add
additional 50 70
loads to 70 Main Breaker Panel
Dedicated Do not add additional
Panels Dedicated GEN, Smart
Dedicated Inverter loads to Dedicated
Load, or AC-Coupled Combiner Panels
Combiner Panel Output Combiner Panel

DRAWING #6000XP-V1-1L-4, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
4a. 3 6000XPs - Whole Home Backup with Grid Input by Service Entrance Panel (Option 1) (with Notes)

PV Panel EG4 6000XP Inverter 2023 NEC 690.12(C) 2023 NEC 706.15 IMPORTANT NOTE: The EG4 6000xp
Strings See MPPT Battery LOAD GRID GEN PV inverter is not capable of providing
Wiring Comm
Port
RSD/ESS sell-back power to the utility. It is only
Diagrams Gen
BAT+ BAT-
Disconnect a backup or off-grid inverter with the
& EG4
2-Wire
Start/Stop
RSD
Initiator Service Entrance Panel capability of grid INPUT for charging
String Sizer IMO batteries or passing through grid
G N BG10P34-11 100- power through the load port to a
2023 NEC 690.15 or equiv 200 A critical loads subpanel or transfer
PV Isolator/ switch. It is essentially a battery
70 charger. Therefore it is not regulated by
Disconnect
EG4 6000XP Inverter
70 the NEC 705 (2023) Interconnection
IMO SI-Series
or equiv. Battery
CT
LOAD GRID GEN PV Utility code.
2 poles/string
Comm
Port
Port 70 Meter
Gen
2-Wire RSD BAT+ BAT-
Start/Stop

G N
A cost-effective way to provide the
G N Locate near multiple grid input circuits needed for
EG4 outdoor service a multiple inverter configuration is
Batteries entrance for Manual through a Service Entrance Panel
EG4 6000XP Inverter access by utility & Transfer On (sometime called a Service Entrance
first responders. Off Combination Panel). Any Main
Battery
CT
LOAD GRID GEN PV Switch
Breaker panel can be used - however
Comm
Port
Port
100-200 A On
See Battery Gen
2-Wire RSD BAT+ BAT- the majority of house loads should be
Wiring on a separate Main Breaker Panel as
Start/Stop
GE TC10324
Diagrams PV System or equiv. shown if backup of those circuits is
G N Disconnect wanted.
Locate near 2023 NEC 690.13
outdoor 100-200 A
service (Eaton
DG224URK L1 L2
entrance for
access by or equiv.)
2-Wire Start/Stop Whole home backup can be achieved
utility and first
responders. with multiple inverters. Since each
OR N L1 L2 G 200 inverter can supply 25 Amps
OR N G
N L1 L2 G continuous of backup power and can
Smart AC pass-through 50 Amps of AC input
Generator 50-125
Load (EV) Coupled power, 3-6 inverter setups can
30-125A 100-200 provide the majority of what most
Inverter(s) 50
homes need on a continuous basis.
50 70 To match the full output of a 200 Amp
Distribution Breakers for the dedicated Gen Port
Combiner Panel should be sized to distribute 50 70 utility service (160 A continuous) you
total Input amperage evenly up to 50 Amp per Do not add 70 Main Breaker Panel would need 6 inverters (you would be
inverter. For example if you have a 60 Amp additional at 150 Amps). Most homes don’t
rated Generator then the main breaker would Dedicated GEN, Smart Do not add additional
loads to Dedicated Inverter loads to Dedicated draw anywhere near the 160 amps
be 80 A and each inverter breaker would be 30 Dedicated Load, or AC-Coupled Combiner Panels available from the utility and function
Amps for 3 inverters (20A x 1.25 & next size). Panels Combiner Panel Output Combiner Panel usually in the 80-120 Amp range
The AC Input and Output circuits must be sized to match total amperage in and out. Three inverters as shown will only produce 75 hence 4 or 5 inverters will cover most
Amps continuous (and hence need a 100 Amp circuit) but can pass through 150 Amps of Grid power and so a 200 Amp circuit will homes. A load assessment is called
allow full pass-through current if needed. 200 Amp circuits are recommended for 3 or more inverters. For choosing breakers for for when trying to achieve whole
individual inverters a 40 A Breaker will allow for full inverter output but a 70 A breaker is needed for full 50 Amp pass-through (50 x home backup.
1.25 = 62.5 Amps per inverter - next sized breaker = 70 A). Alternately a 60 Amp breaker will allow 48 Amps of pass-through.

DRAWING #6000XP-V1-1L-4N, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
5. 3 6000XPs - Whole Home Backup with Grid Input by Service Entrance Panel (Option 2)

PV Panel EG4 6000XP Inverter 2023 NEC 690.12(C) 2023 NEC 706.15
Service Entrance Panel
Strings See MPPT Battery LOAD GRID GEN PV Locate near
Wiring Comm
Port
RSD/ESS outdoor service
Diagrams Gen Disconnect entrance for
BAT+ BAT-
& EG4 200
2-Wire RSD
Start/Stop Initiator access by utility &
String Sizer IMO first responders.
G N BG10P34-11 100
2023 NEC 690.15 or equiv Utility
PV Isolator/ Meter
Disconnect
EG4 6000XP Inverter G N
IMO SI-Series
or equiv. LOAD GRID GEN PV
N L1 L2 G
Battery
Comm CT

2 poles/string Port
Port

Gen
2-Wire
Start/Stop
RSD BAT+ BAT- Manual
100-200 Transfer On
G N Switch Off
60
EG4 200 A On
60
Batteries EG4 6000XP Inverter 60 GE TC10324
or equiv.
Battery
CT
LOAD GRID GEN PV
Comm
Port
Port
Dedicated Inverter
See Battery Gen
2-Wire RSD BAT+ BAT- Grid Combiner Panel
Wiring
Start/Stop
L1 L2
Diagrams PV System
G N
Locate near Disconnect
outdoor 100-200A
service N 200 G
entrance for (Eaton
access by 2023 NEC DG224URK
2-Wire Start/Stop or equiv.)
utility and first 690.13
responders.
OR N L1 L2 G
OR
N L1 L2 G
Smart AC
Generator 50-125
Load (EV) Coupled Main Breaker Panel
30-125A 100-200
Inverter(s) 50
50 60 Do not add
Do not add additional
additional 50 60 loads to
loads to 60 Dedicated
Dedicated Panels
Panels Dedicated GEN, Smart
Load, or AC-Coupled Dedicated Inverter
Combiner Panel Output Combiner Panel

DRAWING #6000XP-V1-1L-5, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
5a. 3 6000XPs - Whole Home Backup with Grid Input by Service Entrance Panel (Option 2) (with Notes)

PV Panel EG4 6000XP Inverter 2023 NEC 690.12(C) 2023 NEC 706.15
Service Entrance Panel IMPORTANT NOTE: The EG4
Strings See MPPT Battery LOAD GRID GEN PV Locate near 6000xp inverter is not capable of
Wiring Comm RSD/ESS outdoor service
Diagrams
Port
Disconnect entrance for providing sell-back power to the
utility. It is only a backup or
Gen
BAT+ BAT-
& EG4 200
2-Wire RSD
Start/Stop Initiator access by utility &
String Sizer first responders. off-grid inverter with the
IMO capability of grid INPUT for
G N BG10P34-11 100
2023 NEC 690.15 or equiv Utility charging batteries or passing
Meter through grid power through the
PV Isolator/ load port to a critical loads
Disconnect subpanel or transfer switch. It is
EG4 6000XP Inverter G N
IMO SI-Series essentially a battery charger.
or equiv. LOAD GRID GEN PV Therefore it is not regulated by
N L1 L2 G
Battery
Comm CT

2 poles/string Port
Port
the NEC 705 (2023)
Gen
2-Wire
Start/Stop
RSD BAT+ BAT- Manual Interconnection code.
100-200 Transfer On
G N Switch Off A cost-effective way to provide the
60
EG4 200 A On multiple grid input circuits needed
60 for a multiple inverter configuration
Batteries EG4 6000XP Inverter 60 GE TC10324 is through a Service Entrance Panel
or equiv. (sometime called a Service Entrance
Battery LOAD GRID GEN PV
Comm
Port
CT
Port Dedicated Inverter Combination Panel). Any Main
See Battery Gen
2-Wire RSD BAT+ BAT- Grid Combiner Panel Breaker panel can be used -
Wiring
Start/Stop
L1 L2 however the majority of house
Diagrams PV System loads should be on a separate Main
G N Breaker Panel as shown if backup of
Locate near Disconnect those circuits is wanted.
outdoor 100-200A
service N 200 G
entrance for (Eaton
access by 2023 NEC DG224URK
2-Wire Start/Stop or equiv.)
utility and first 690.13
responders.
OR N L1 L2 G
OR
N L1 L2 G
Smart AC
Generator 50-125
Load (EV) Coupled Main Breaker Panel
30-125A 100-200
Inverter(s) 50 The AC Input and Output circuits must be sized to
50 60 Do not add match total amperage in and out. Three inverters
Distribution Breakers for the dedicated Gen Port 50 60 additional as shown will only produce 75 Amps continuous
Combiner Panel should be sized to distribute loads to (and hence need a 100 Amp circuit) but can pass
total Input amperage evenly up to 50 Amp per 60
Do not add Dedicated through 150 Amps of Grid power and so a 200
inverter. For example if you have a 60 Amp Dedicated GEN, Smart Panels
rated Generator then the main breaker would additional Amp circuit will allow full pass-through current if
be 80 A and each inverter breaker would be 30 loads to Load, or AC-Coupled Dedicated Inverter needed. 200 Amp circuits are recommended for
Amps for 3 inverters (20A x 1.25 & next size). Dedicated Combiner Panel Output Combiner Panel more than 3 inverters. For choosing breakers for
Panels individual inverters a 40 A Breaker will allow for
Whole home backup can be achieved with multiple inverters. Since each inverter can supply 25 A continuous of backup power full inverter output but a 70 A breaker is needed
and can pass-through 50 A of AC input power, 3-6 inverter setups can provide the majority of what most homes need on a for full 50 Amp pass-through (50 x 1.25 = 62.5
continuous basis. To match the full output of a 200 A utility service (160 A continuous) you would need 6 inverters (you would Amps per inverter - next sized breaker = 70 A).
be at 150 A). Most homes don’t draw anywhere near the 160 amps available from the utility and function usually in the 80-120 Alternately a 60 Amp breaker will allow 48 Amps
A range hence 4 or 5 inverters will cover most homes. A load assessment is called for when trying to achieve whole home of pass-through.
backup.

DRAWING #6000XP-V1-1L-5N, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
6. 3 6000XPs - Whole Home Backup with Grid Input by Supply Side Tap

Locate near outdoor


service entrance for Locate near outdoor
2023 NEC 2023 NEC service entrance for
access by utility & EG4 6000XP Inverter 690.12(C) 706.15 access by utility &
first responders first responders.
Utility
Battery LOAD GRID GEN PV RSD/ESS Meter
Comm

Gen
Port
Disconnect PV System
BAT+ BAT-
PV Isolator/
2-Wire
Start/Stop
RSD
Initiator Fused
Disconnect
IMO Disconnect
G N BG10P34-11 200A 2023 NEC Supply
IMO SI-Series or equiv 690.13
or equiv.
Siemens Side
HF224NR Tap
2023 NEC 690.15 or equiv.
EG4 6000XP Inverter
LOAD GRID GEN PV
Battery
Comm N L1 L2 200A
Do not add Main
Port
Gen
2-Wire RSD BAT+ BAT- additional
Start/Stop
loads to Service
200
EG4 G Dedicated Breaker
G N Panels Square D
Batteries 60
60 QOM2200VH
or equiv.
EG4 6000XP Inverter 60
Bond N to N G
LOAD GRID GEN PV
See Battery Battery
G here and
Dedicated Grid
Comm

Wiring Port
only here.
Diagrams
Gen
2-Wire
Start/Stop
RSD BAT+ BAT- Input Combiner Panel
Manual On
G N Transfer Off
Switch(*) On
N L1 L2
2-Wire Start/Stop
GE TC10324
200 or equiv.
N L1 L2 G G
OR OR
60
AC 60 L1 L2
Generator Smart
Load (EV) Coupled 200 60
30-125A Do not add
Inverter(s) additional 50
loads to 50 Dedicated Inverter N 200 G
Dedicated 50 Output Combiner Panel
Panels

Dedicated GEN, Smart


Load, or AC-Coupled
Combiner Panel
Main Breaker Panel

DRAWING #6000XP-V1-1L-6, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
6a. 3 6000XPs - Whole Home Backup with Grid Input by Supply Side Tap (with Notes)
IMPORTANT NOTE: The EG4 6000xp
Locate near outdoor Utility Meter inverter is not capable of providing
service entrance for Locate near outdoor sell-back power to the utility. It is
2023 NEC 2023 NEC service entrance for only a backup or off-grid inverter
access by utility & EG4 6000XP Inverter 690.12(C) 706.15 access by utility & with the capability of grid INPUT for
first responders first responders. charging batteries or passing
Battery LOAD GRID GEN PV RSD/ESS
Comm through grid power through the load
Gen
Port
Disconnect PV System port to a critical loads subpanel or
BAT+ BAT- transfer switch. It is essentially a
PV Isolator/
2-Wire
Start/Stop
RSD
Initiator Fused
battery charger. Therefore it is not
Disconnect
IMO Disconnect regulated by the NEC 705 (2023)
G N BG10P34-11 200A 2023 NEC Supply Interconnection code.
IMO SI-Series or equiv
or equiv.
Siemens 690.13 Side
HF224NR Tap Supply Side Taps allow you to feed
2023 NEC 690.15 or equiv. the full pass-through capability of
EG4 6000XP Inverter the inverter to either your critical
LOAD GRID GEN PV loads subpanel or to a transfer
Battery
Comm N L1 L2 200A
Do not add switch back to the Main Breaker
Main
Port
Gen
2-Wire RSD BAT+ BAT- additional Panel. Since the 6000 XP has a 25
Start/Stop
loads to Service Amp Off-grid output and a50 A
100-200 Dedicated
EG4 G
Panels
Breaker pass-through rating from the Grid or
G N Square D
70 a Generator you can achieve whole
Batteries Bond QOM2200VH panel or whole home backup by
70
Neutral to or equiv. using 4-6 Inverters in parallel.
EG4 6000XP Inverter 70 Ground N G
LOAD GRID GEN PV here and
See Battery Battery
only here Caution: A Supply Side Tap will
Wiring
Comm
Port Dedicated Grid essentially add loads to your Service
Diagrams
Gen
2-Wire
Start/Stop
RSD BAT+ BAT- Input Combiner Entrance since the 6000XP adds
Panel Manual On close to 30 Amps per inverter to the
total house loads with it’s battery
G N Transfer Off
chargers. With this increased load
Switch(*) On there is the very real danger of
N L1 L2 overloading the Service Entrance
conductors if the home is already
2-Wire Start/Stop using the full capacity of a 200 A
GE TC10324
100-200 or equiv. Service. Do this under advisement
N L1 L2 G G of your electrician and/or Electrical
OR OR Inspector. Alternatively use a
70
AC L1 L2 Feeder Tap to mitigate this issue.
Smart 70
Generator Feeder taps locate this extra load on
Load (EV) Coupled 200 70 the load side of the Main Breaker -
30-125A
Inverter(s) 50
thus protecting all Service Entrance
Conductors. (See Feeder Tap
Distribution Breakers for the dedicated Gen 50 Dedicated Inverter N 200 G Diagram).
Port Combiner Panel should be sized to 50 Output Combiner Panel Supply Side Taps should be installed
distribute total Input amperage evenly up to by a professional electrician. Ilsco
50 Amp per inverter. For example if you have Do not add
a 60 Amp rated Generator then the main additional Dedicated Generator, KUP-L-Taps are recommended, but
loads to Smart Load, or AC-Coupled the installer must adhere strictly to
breaker would be 80 A and each inverter installation instructions with proper
breaker would be 30 Amps for 3 inverters Dedicated Combiner Panel
Panels torque applied (as measured with a
(20A x 1.25 & next size). torque wrench). Alternatively, a
The AC Input and Output circuits must be sized to match total amperage in and out. Three inverters as shown will only Main Breaker Panel Polaris or Burnby Insulated MultiTap
produce 75 Amps continuous (and hence need a 100 Amp circuit) but can pass through 150 Amps of Grid power and so a Connector can be used, but these
need to be torqued twice - once
200 Amp circuit will allow full pass-through current if needed. 200 Amp circuits are recommended for 3 or more inverters. upon installation and once 24 hours
For choosing breakers for individual inverters a 40 A Breaker will allow for full inverter output but a 70 A breaker is needed later.
to allow full 50 Amp pass-through (50 x 1.25 = 62.5 Amps per inverter - next sized breaker = 70 A). Alternately a 60 Amp
breaker will allow 48 Amps of pass-through. Refer to EG4 Design Guides for
discussion of partial home and
whole home backup.
DRAWING #6000XP-V1-1L-6N, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
7. 3 6000XPs - Whole Home Backup with Grid Input by Feeder Tap
Locate near outdoor
service entrance for
access by utility & EG4 6000XP Inverter
first responders 2023 NEC 2023 NEC
Battery LOAD GRID GEN PV 690.12(C) 706.15
Comm

Utility
Port
Gen
2-Wire BAT+ BAT- RSD/ESS
Meter
RSD

PV Isolator/ Start/Stop
Disconnect Locate near
Disconnect outdoor service
Initiator entrance for
G N
IMO SI-Series IMO access by utility &
or equiv. BG10P34-11 first responders.
or equiv Bond N to 200A
2023 NEC 690.15
EG4 6000XP Inverter
G here and Main
only here Service
LOAD GRID GEN PV L2 G
N L1 2023 NEC 690.13 Breaker
Battery
Comm CT
Port
Port
(Square D
Gen
2-Wire
Start/Stop
RSD BAT+ BAT- PV System QOM2200VH
200 Fused or equivalent)
EG4 G N Disconnect
Batteries 70 200A N G
70 Siemens
EG4 6000XP Inverter 70 HF224NR
or equiv.
See Battery
Battery LOAD GRID GEN PV 200 Amp
Dedicated Inverter
Comm CT

Feeder Tap
Port
Wiring
Port

Diagrams
Gen
BAT+ BAT- Grid Combiner Panel
Manual
2-Wire RSD
Start/Stop

On Transfer
G N N L1 L2 G Switch L1 L2
Off
On 200 A
200 GE TC10324
or equiv. N 200 G
2-Wire Start/Stop 70
Do not add
70 additional
N L1 L2 G
OR OR 70 loads to
AC Dedicated
Generator Smart 50-125 Dedicated Inverter Panels
Load (EV) Coupled
30-125A Do not add Output Combiner Panel
Inverter(s) additional 50
Main Breaker Panel
loads to 50
Dedicated 50
Panels

Dedicated GEN, Smart


Load, or AC-Coupled
Combiner Panel

DRAWING #6000XP-V1-1L-7, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
THIS DIAGRAM IS FOR ILLUSTRATIVE PURPOSES ONLY. EG4™ IS NOT RESPONSIBLE FOR ACCURACY. FINAL WIRING DIAGRAMS SHOULD BE
GENERATED BY A LICENSED PROFESSIONAL AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION INCLUDING MUNICIPAL, COUNTY,
STATE OR ANY OTHER GOVERNMENT OR REGULATORY ENTITY WHICH REGULATES THE USE OF THIS EQUIPMENT WHERE IT MAY BE INSTALLED.
7a. 3 6000XPs - Whole Home Backup with Grid Input by Feeder Tap (with Notes)

Locate near outdoor


service entrance for
access by utility & EG4 6000XP Inverter Utility Meter IMPORTANT NOTE: The EG4
first responders 2023 NEC 2023 NEC 6000xp inverter is not
LOAD GRID GEN PV capable of providing
Battery
Comm 690.12(C) 706.15
Port
Gen
sell-back power to the utility.
2-Wire RSD BAT+ BAT- RSD/ESS It is only a backup or off-grid
PV Isolator/ Start/Stop
Disconnect Locate near inverter with the capability
Disconnect outdoor service of grid INPUT for charging
Initiator entrance for
G N batteries or passing through
IMO SI-Series IMO access by utility & grid power through the load
or equiv. BG10P34-11 first responders. port to a critical loads
or equiv 200A subpanel or transfer switch.
2023 NEC 690.15 Main It is essentially a battery
EG4 6000XP Inverter
Service charger. Therefore it is not
LOAD GRID GEN PV N L1 L2 G regulated by the NEC 705
2023 NEC 690.13
Battery

Breaker
Comm CT
Port
Port
(2023) Interconnection code.
Gen
2-Wire RSD BAT+ BAT- PV System (Square D
QOM2200VH
Start/Stop

200 Fused Feeder Taps should be


Disconnect or equivalent) installed by a professional
EG4 G N electrician. Ilsco KUP-L-Taps
Batteries 60 200A N
G are recommended, but
60 Siemens Bond N to G installer must adhere strictly
EG4 6000XP Inverter 60 HF224NR here and to installation instructions
or equiv. only here. with proper torque applied
LOAD GRID GEN PV (as measured with a torque
See Battery Battery
Comm CT
Dedicated Inverter
Wiring
Port
Port
200 Amp wrench). Alternatively, a
Diagrams
Gen
BAT+ BAT- Grid Combiner Panel Polaris or Burnby Insulated
Manual
2-Wire
Feeder Tap
RSD

MultiTap Connector can be


Start/Stop

On Transfer used, but these need to be


G N N L1 L2 G Switch torqued twice - once upon
Off L1 L2 installation and once 24
On 200 A hours later.
2-Wire Start/Stop 200 GE TC10324
or equiv. Whole home backup can be
N 200 G achieved with multiple
N L1 L2 G 60 inverters. Since each inverter
OR OR 60
Do not add
can supply 25 Amps
additional
AC 60 loads to continuous of backup power
Generator Smart 50-125 Dedicated and can pass-through 50
Load (EV) Coupled Amps of AC input power, 3-6
30-125A Dedicated Inverter Panels
Inverter(s) 60 inverter setups can provide
Output Combiner Panel Main Breaker Panel the majority of what most
60 homes need on a continuous
Distribution Breakers for the dedicated Gen
Port Combiner Panel should be sized to 60 The AC Input and Output circuits must be sized to match total basis. To match the full
distribute total Input amperage evenly up amperage in and out. Three inverters as shown will only output of a 200 Amp utility
Do not add service (160 A continuous)
to 50 Amp per inverter. For example if you
additional
Dedicated GEN, produce 75 Amps continuous (and hence need a 100 Amp you would need 6 inverters
have a 60 Amp rated Generator then the SmartLoad, or AC-Coupled circuit) but can pass through 150 Amps of Grid power and so a
main breaker would be 80 A and each loads to (you would be at 150 Amps).
Dedicated Combiner Panel 200 Amp circuit will allow full pass-through current if needed. Most homes don’t draw
inverter breaker would be 30 Amps for 3
inverters (20A x 1.25 & next size). Panels 200 Amp circuits are recommended for 3 or more inverters. For anywhere near the 160 amps
choosing breakers for individual inverters a 40 A Breaker will available from the utility and
allow for full inverter output but a 70 A breaker is needed to function usually in the 80-120
allow full 50 Amp pass-through (50 x 1.25 = 62.5 Amps per Amp range hence 4 or 5
inverter - next sized breaker = 70 A). Alternately a 60 Amp inverters will cover most
homes. A load assessment is
breaker will allow 48 Amps of pass-through. called for when trying to
achieve whole home backup.

DRAWING #6000XP-V1-1L-7N, VERSION 1.2 ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.