Weberfloor 514 SL-KSA
Weberfloor 514 SL-KSA
Weberfloor 514 SL-KSA
PRODUCT
floor 514 SL is an underlay cementitious base single
component product, used internally for leveling and smoothing
irregular surfaces at thicknesses up to 15mm, on new or
existing substrates in order to receive different types of
flooring covering. It has good abrasion resistance and
provides a fast setting tough surface that will accept light
traffic in less than 12hours with an excellent resistance to
light loads and traffic.
SCOPE OF USE
floor 514 SL is used for internal application and specially
designed to be applied as self-leveling prior the laying of
resilient floors such as PVC, Vinyl, rubber, carpets as well as
wood flooring, ceramics, or natural stones. It can be used in
many areas such as:
• Hotels, theaters, hospitals PACKAGING
• Schools, offices Leb Syria Jordan UAE Qatar Kuwait KSA Oman
• Airports halls. - - - - - - 25 kg -
floor 514 SL can be used also for levelling existing
concrete pavements, terrazzo, or natural stone after a good
surface preparation and priming. It could be applied over
light weight screed.
floor 514 SL could be used for floor heating system Compressive strength at 25 MPa ± 10%
according to special instructions respecting the start-up 28 days EN 13813:2003
heating procedure. VOC and formaldehyde None (<10µg/l)
Content ISO/FDIS
ADVANTAGES 11890-2/GC-MS
*The mentioned results are obtained @ 20 % water ratio.
• Highly fluid and easily workable. *Properties listed above are only based on controlled laboratory
• Good self levelling capacity. samples and tests: Results may differ based upon statistical variations
• Fast setting ready for foot traffic in less than 12h (depending depending upon mixing methods and equipment, temperature, application
on thickness and site conditions) methods, test methods, actual site conditions and curing conditions.
• Smooth finishing.
• Good bond with reduced shrinkage. APPLICABLE STANDARDS
• Low VOC. EN 13813 CT,
EN 12808,
CHARACTERISTICS EN 12706:1999
Form Grey Powder
Grain size < 1 mm INSTRUCTIONS FOR USE
Density 2.1 ± 0.05 SUBSTRATE PREPARATION
Shelf healing properties Good up to approx. 30 min • Concrete substrate should be at least 3 months old and
(depending on temperature, structurally stable. (residual moisture <4%)
substrate & site conditions) • Concrete must be crack free. Thus, any crack must be
Pot life around 30 min repaired prior to application.
Application temperature from +5°C to +35°C • All surfaces should be clean, dry, and free from grease,
range laitance, oil, dust, paint and any other substance that may
Shrinkage at 28 days - IBN <0.5 mm/m prevent or reduce adhesion.
German guideline: 1993 • Remove all weak, loose, smooth or broken pieces of
Flexural strength at 28 6 MPa concrete, until reaching a sound rough concrete. This can be
days EN 13813:2003
achieved primarily by shot-blasting otherwise by medium prepared surface, then immediately spread it with a large
scarifying or grinding. metal trowel. Moreover ,the spiked roller could be also used
• The prepared surface must have an average “surface to eliminate and burst the air bubbles and pinholes and to
tensile adhesion strength” greater than 1MPa. Moreover, it homogenize the product mixture to aid in leveling and
should have CSP (concrete surface profile) of 3 to 5. smoothing the surface. Do not walk in the wet material
• Then, the substrate must be vacuumed, and primed with unless wearing spiked shoes or boots. Always keep a wet
floor 4716. Weber does not warrant any defect due to edge of material to pour fresh material into. Protect the
concrete substrate movement. material from wind when installing. Allow longer cure time of
the material before walking on if the temperature is below
PRIMER APPLICATION 21°C.
• floor 4716 must be brushed into the substrate using a floor 514 SL can be covered (vinyl, carpet, tiles...) after 3
soft brush. Primer’s Puddles should be avoided. days from the application.
• floor 4716 must be applied on one or two coats
depending on the substrate. PRECAUTIONS
• For dry and porous substrate, dilute first coat of floor It is preferable to subdivide the total area of application in
4716 with water at the ratio 1:5. Allow to dry to a clear film smaller ones not exceeding 20 m² each in order to facilitate
before applying the second layer with a dilution 1:3. the application of floor 514 SL. A soft frame should be fixed so
For dense concrete, apply one coat of weberfloor 4716 when they finish the first section, you should remove the soft
diluted at the ratio of 1:3 frame and apply the other section without leaving any joint
Kindly refer to the primer data sheet for more details between the 2 sections. All existing movement/expansion
• floor 514 SL should be applied as soon as the colour of joints in the base should be maintained and continued
the primed surface change from white to clear. For thick- through the weberfloor 514 SL
nesses higher than 10mm, it is recommended to fix soft strips • In case of corridors, it is recommend it to fix control joints on
as a separation between the walls (or columns) and the each 15 linear meters and in each connection between corri-
self-leveling before proceeding with the application. dor and room. The joints should be sealed with weber
jointseal PU.
PRODUCT PREPARATION • In hot and humid weather, it is preferable to apply the prod-
floor 514 SL is to be mixed in full bag batches. Do not uct early morning or late afternoon.
mix partial bags. 25 Kg bag of floor 514 SL is to be mixed • outside the recommended temperature range (higher than
with 4.9 - 5.2 lit of clean and cool water. Measure and add the 35 deg.), please refer to the technical department for more
proper amount of water for each bag into a mixing container. details about the thickness and the method of application
Using a paddle type mixer on a slow speed drill, place the • Avoid work under heavy windy condition in which case the
paddle in the mixing water and start the drill. Slowly add the product may dry fast and cracks might appear. It is preferable
floor 514 SL powder. Mix for a minimum of 2 minutes to cover the working area with plastic sheets as soon as the
until lumps free mixture. Scrape the sides of the mixing surface is walkable.
container and remix for 1 minute. The mixed material should • All the opening ( windows , doors..) should be closed in order
be lumps free Make sure that the mixed material has a to reduce the effect of wind during the application and while
temperature not exceeding 30C (use ice if necessary to cool the applied area still fresh. Any applied materials should be
down water). . protected from sun light.
It is recommended to fix soft strips as a separation between • The surface is suitable for light foot traffic after 24 hours.
However, avoid dragging heavy objects on it in order to
the walls (or columns) and the self-leveling before proceeding with
avoid damaging the finished surface.
the application at thicknesses greater than 10 mm..
• After usage, clean tools with water.
• Depending on thickness, moisture content of self levelling
Note: Do not add more water to a mix which has already
and substrate, and the moisture sensitivity of the covering,
begun to set.
wait 3 days minimum before covering the floor with carpeting,
tiles, etc.
PRODUCT APPLICATION • For additional information, please consult our Technical
Limit the work areas into manageable sections of approximately Data Sheet or contact one of our Sales Engineers.
20 m2 .Reduce the width of the work area when applying in
warmer temperatures. Pour the mixed material onto the
CLEANING
Tools and equipment should be cleaned with water
immediately after use.
STORAGE
One year after manufacturing date in its original packing non
open and in dry cool area.
SAFETY PRECAUTIONS
The product contains very fine powders which, when mixed
with water, release alkalis that could be harmful to the skin. It
is preferable to do the application a well ventilated area, to
wear protective gear for hands, eyes and respiratory system
and to avoid dust inhaling. Splashes on the skin should be
washed away by cleaning with soap and water. In case of
contact with eyes, wash thoroughly with clean water. If
swallowed, do not induce vomiting. In both cases seek medi-
cal attention. The product is non-flammable.
DISCLAIMER
While the company guarantees its products against defective
materials, the use and application of these products are
made without guarantee since the conditions of their appli-
cation are beyond its control. It is recommended to verify
with the company that the product is suitable for the intend-
ed use, and that this Data Sheet version is the latest one. The
company may modify it without prior notice. Technical charac-
teristics are listed for guidance only. For more information,
please contact the company’s office in your location.
NOTE
The information included on this Technical Data Sheet is the sole
property of Saint-Gobain Middle East Holding SAL (previously
SODAMCO Holding). The unauthorized disclosure, use,
dissemination or copying (either whole or partial) of this data
sheet or any information it contains, is prohibited and
subject to legal pursuit.