Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

35gpm @9

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Vertical

Multistage
Pumps

91 of 181
AN INTRODUCTION TO NAFFCO
NAFFCO was founded in Dubai, UAE to become the world’s Our products have been consistently certified by UL, FM, BSI,
leading producer and supplier of life safety solutions. By LPCB and Global Mark according to the latest International
recognizing the importance and convenience of having easy Quality Standard for their strict adherence to ISO 9001 quality
access to multiple safety services, we became specialized by management system and certified for ISO 14001 environmental
offering complete solutions under one roof for all types of high management systems and BS OHSAS 18001 for occupational
quality firefighting equipment, fire protection systems, fire alarms, safety by UL DQS.
addressable emergency systems, security systems,custom-
made vehicles such as fire trucks, ambulances, mobile hospitals Our success is driven by our passion to protect; our vision is to
and airport rescue firefighting vehicles (ARFF). become the world’s number one provider of innovative solutions
in protecting life, environment and property.
With the most talented and dedicated employees from around
the world, NAFFCO has over 450 passionate engineers and over
3 million square feet of manufacturing facilities. We are currently
exporting to over 100 countries worldwide.

92 of 181
2 www.naffco.com
PERFORMANCE CURVES

NF-VL 8 50Hz
2900rpm

240
230
220 -200
210
200 -180
190
180
-160
170
160
150 -140

140
130 -120
Head (m)

120
110 -100
100
90 -80
80
70
-60
60
-50
50
-40
40
30 -30

20 -20

10 -10
0
0 1 2 3 4 5 6 7 8 9 10 11
Capacity (m3/h)

0.50

0.40
Power (kW), Stage = 1

0.30

0.20

0.10

0.00

60

50

40
Efficiency (%)

30

20

10

2.0

1.6

1.2
NPSHR (m)

0.8

0.4

0.0
0 1 2 3 4 5 6 7 8 9 10 11

Capacity (m /h)
3

8 www.naffco.com
NAFFCO VERTICAL MULTISTAGE PUMPS
NF-VL / NF-VLS is a vertical multistage in-line pump able for using as a pressure maintenance pump (Jockey
series with all wetted parts made of stainless steel. It is Pump) in firefighting applications and it meets NFPA 20
suitable for a variety of different applications involving requirements for Jockey Pumps. Each pump set is
various liquids from potable water to industrial effluent and tested in our factory, prior to dispatch, to confirm that the
cover a wide range of flow and pressure requirements. performance is achieved per the specified requirements.

The major features of this series pumps are efficient FEATURES


operation, low noise, compact structure, light weight, • Reliable Performance • Stringent Tests
easy to service, good seal performance etc. Its high head
low capacity performance range makes it especially suit- • Easy to Service • Quality Materials
• Efficient Operation • Longer Service Life

READING THE MODEL NAME CROSS SECTIONAL DRAWING


Example: NF-VL 4-120 1

NF - Series Name 2
16
VL - Vertical Multistage 3

4 - Nominal Capacity in m3/hr 4

120 - Number of Stages x 10 5

Note: Letter ‘S’ will be added to ‘VL’ for the models that are designed 6
for 60 Hz operation. 15
7

SL. 8 14
PART NAME MATERIAL STANDARD
NO. 13
9
1 Electric Motor Aluminum Frame 12

Driver Pedestal ASTM A48 11


2 Cast iron
(Motor Base) Class 25 B 10
3 Seal Base Stainless Steel AISI 304
Tungsten
4 Mechanical Seal
Carbide / Graphite
NF-VL(S) 4
5 Top Diffuser Stainless Steel AISI 304
6 Diffuser Stainless Steel AISI 304
1
7 Support Diffuser Stainless Steel AISI 304 16
2
8 Inducer Stainless Steel AISI 304
3
Suction &
9 Discharge Stainless Steel AISI 304 4
Chamber
5
ASTM A48
10 Pump Base Plate Cast Iron
Class 25 B
6
11 Bearing Tungsten Carbide 15

12 Impeller Stainless Steel AISI 304 7


14
13 Shaft Stainless Steel AISI 304
8 13
14 Impeller Sleeve Stainless Steel AISI 304
12
9
Outer Sleeve
15 Stainless Steel AISI 304
(Cylinder) 11

16 Coupling Carbon Steel AISI 1040


17 O ring FPM
ASTM A48
18 Flanges Cast Iron
Class 35 B
Table 1 10

NF-VL(S) 8, 16

93 of 181
www.naffco.com 3
SPECIFICATIONS

LIQUID DATA PUMP DATA


Pumped Liquid Type : Thin, clean and Pump Design Test : ISO 9906
non-aggressive, non-explosive Standard
liquids, not containing solid
particles or fibers. Nozzle Connections : Flanged
Liquid pH range : pH 5-9 Nozzle Connection : EN 1092-2
Design Standard
Temperature Range
Flange Rating and : Refer Table of Dimensions
Standard Design : -15°C to +90°C Type
Hot water Design : -15°C to +120°C ANSI/HI 2.1-2.2 : Vertical in-line casing diffuser
Designation pump (VS8)
Pump Bearing : Pumped Liquid
ELECTRIC MOTOR DATA
Lubrication
Enclosure : V18 (“C” Type Face at
Shaft Shape : Double-D
Drive End) < 4 kW
(for securing impeller
on to the shaft)
V1 (“D” Type Flange at
Drive End) > 5.5 kW Mechanical Seal : Cartridge Type

Shaft Down, No Feet Minimum Suction : Refer the NPSH Curve of the
Pressure Required corresponding pump model

Standard : IEC 60034 Maximum Suction : Please refer the below Table
Pressure No. 2
Voltage : 380-415 V
460 V

Phase : 3 Maximum Suction


Pump Model
Frequency : 50 / 60 Hz Pressure (bar)
Insulation Class : F 50 Hz

Enclosure IP Rating : IP55 NF-VL 4-10 – NF-VL 4-20 6


NF-VL 4-30 – NF-VL 4-100 10
Efficiency Class : Eff. 2
NF-VL 4-110 – NF-VL 4-220 15
Noise Level : 85 dB(A) @ 1 m.
NF-VL 8-10 – NF-VL 8-70 6
Ambient Temperature : Standard: 40°C NF-VL 8-80 – NF-VL 8-200 10
High: 50°C with 0.95 & 55°C with NF-VL 16-20 – NF-VL 16-30 6
0.92 derating factors (for other
temperatures refer the below NF-VL 16-40 – NF-VL 16-160 10
Curve No. 1) 60 Hz
Ambient Temperature : Standard: 1000 m NF-VLS 4-20 6
High: 2250 m with 0.95 & 3500 NF-VLS 4-30 – NF-VLS 4-80 10
m with 0.88 derating factors NF-VLS 4-100 – NF-VLS 4-160 15
(for other altitudes refer the
temperature derating curve) NF-VLS 8-10 – NF-VLS 8-50 6
NF-VLS 8-60 – NF-VLS 8-140 10
NF-VLS 16-10 – NF-VLS 16-20 6
NF-VLS 16-30 – NF-VLS 16-100 10
Table 2

94 of 181
4 www.naffco.com