You are on page 1of 8

Level- and temperature

switch
Nivotemp NT 64, NT 64D Fluidcontrol

In hydraulics and lubrication technology the fill level of oil tanks


needs to be monitored continuously. Here, modern factory
automation requires compatible signals. Despite central system
control, visualising the current level on the actual tanks is often
desired. To minimise production costs and the space required
on containers, it makes sense to use one monitor for both e.g.
the fill level and oil temperature. The Nivotemp series meets
virtually all requirements arising in this area of application.

NT 64

Connecting flange as per DIN 24557 Part 2

Wireless, adjustable level contacts

Various plug options

Up to 4 switching outputs for liquid level or 2 switching


outputs for liquid level plus Pt100 or analog output for
temperature

Proven and tested highly dynamic float system

24 V DC standard, 230 V DC upon request

NT 64D

LED display with status of switching outputs, 270° swivel

Standard menu structure based on VDMA standard sheet


24574 ff.

2 wireless, adjustable level contacts

Up to 4 programmable temperature switching outputs

Alternatively, continuous temperature output signal plus one


freely programmable switching output
Characteristics of switching output configurable as window or
hysteresis
Two switching outputs configurable as frequency output
(1-100 Hz)

Min/max memory, logbook function

DE100209 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen


Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20
05/2024
E-Mail: fluidcontrol@buehler-technologies.com
page 1 / 8 Internet: www.buehler-technologies.com
Nivotemp NT 64, NT 64D
Technical Data NT 64

Basic unit
Version MS VA Basic model
Operating pressure max. 1 bar max. 1 bar
Operating temperature -20 °C to +80 °C -20 °C to +80 °C

8 with VA stilling
G1 cork

65
Float SK 610 SK 221 seal

Min. fluid density 0.80 kg/dm³ 0.85 kg/dm³

tube
Lengths 280, 370, 500 mm (standard)

L1 = min. 40

4
Material/Version

1st contact
Float rigid PU (SK 610) 1.4571 (SK 221)

Stilling tube optional


Immersion tube Brass 1.4571

L2 = min. 80
Flange (DIN 24557) PA PA
Weight at L=280 mm approx. 200 g approx. 300 g

L
Each 100 mm add approx. 30 g approx. 50 g
Includes:
Mounting screws (quantity 6) and rubberised cork seal. last
Ø50 (MS)
Ø60.3 (VA)
contact
Options

min. 60
Stilling tube (SSR) Brass VA
Level switching output K101-104 W101/102
Function NO/NC* Change-over contact

3.5
Ø44

Max. number 4 2
Voltage max. 30 V DC 30 V DC
Switching current max. 0.5 A 0.5 A Flange drawing
Contact load max. 10 VA 20 VA Ø60*
Min. contact spacing 40 mm 40 mm
*NO= falling NC contact/NC = falling NO contact
Optional temperature output
Ø90

Temperature contact TK Ø73


6x Ø6
Voltage max. 30 V DC
Switching current max. 2.5 A
Contact load max. 100 VA *min. Ø61 for VA version with
stilling tube
Function NC* NO*
Switching point °C 50/60/70/80 50/60/70/80
Switching point tolerance ±3K ±3K SK 221 Float
Hysteresis max. 10 K ± 3 K 10 K ± 3 K
* NC = NC contact/NO = NO contact, data for rising temperature last contact
Temperature sensor Pt 100 Class B, DIN EN 60 751
min. 55*

Tolerance ±0.8 °C
57

Temperature transmitter KT
Temperature sensor Pt 100 Class B, DIN EN 60 751
3.5

Ø51
Measuring range 0 °C to +100 °C
Supply voltage (UB) 10 - 30 V DC
min. Ø60
Output 4 - 20 mA
min. Ø61 with stilling tube
Burden Ω max. =(UB -7.5 V)/0.02 A
* min. 80 with temperature
Accuracy ± 1 % from end value (in the medium)
Other measuring ranges available upon request

2 Bühler Technologies GmbH We reserve the right to amend specification. DE100209 ◦ 05/2024
Nivotemp NT 64, NT 64D
Ordering instructions NT 64
Model key
NT 64- - - -nn-nn- -
Model designation
Version
MS Brass
VA float / VA immersion tube Optional
Plug connector SSR Stilling tube
M3
S6
Temperature signal
M12
TK... NC contact NO contact
2M12
TK50NC TK50NO = 50 °C
Length in mm TK60NC TK60NO = 60 °C
280 TK70NC TK70NO = 70 °C
370 TK80NC TK80NO = 80 °C
500 Pt100 Temperature sensor
Level measurement KT Temperature transmitter
1-4 Number of contacts 1)
1) Please specify position and switching function per model
Level contacts key, example: L1 = nnnmm NC
K NC/NO
W change-over contact

Accessories

Item no. Description


9144050010 Connecting cable M12x1, 4-pin, 1.5 m, angular coupling and straight plug
9144050046 Connecting cable M12x1, 4-pin, 3.0 m, angular coupling and straight plug
9144050047 Connecting cable M12x1, 4-pin, 5.0 m, angular coupling and strands

Ordering example

You require: Level switch with flange, brass, plug connector S6, length L = 500 mm, 2 level contacts and temperature contact
TK 80 as NC contact, 1st contact 100 mm NC, 2nd contact 420 mm NO
Order: NT 64-MS-S6-500-2K-TK80NC, L1=100 NC, L2=420 NO

Standard pin assignment NT 64


Plug connection

M3 S6 M12 (base) 2M12 (base)

Dimensions

Number of pins 3-pin + PE 6-pin + PE 4-pin 4-pin / 4-pin


DIN EN 175301-803 175201-804 61076-2-101 61076-2-101
Voltage max. 30 V AC / V DC 30 V AC / V DC 30 V DC 30 V DC
Contact load max. 0.5 A per output 0.5 A per output 0.5 A per output 0.5 A per output
Degree of protection IP65 IP65 IP67* IP67*
Cable fitting PG11 M20x1.5
Max. number of contacts
1 x K101 / 1 x TK 3 x K101-104 / 1 x TK 1 x K101 / 1 x TK 3 x K101-104 / 1 x TK
Level/temp. contacts
-/- 1 x W101/102 / 1 x TK -/- 1 x W101/102 / 1 x TK
Level contacts only 2 x K101-102 4 x K101-104 4 x K101-102 4 x K101-104
1 x W101 2 x W101/102 2 x W101 1 x W101/102
* with IP67 cable box attached. Other plug connections available upon request.

DE100209 ◦ 05/2024 We reserve the right to amend specification. Bühler Technologies GmbH 3
Nivotemp NT 64, NT 64D
M3 S6 M12 (base) 2 x M12 (base)

Connection schematic Plug A Plug B


3 5 4

6 3
2 1
1 2

PE PE

K101-104
Level contact(s)

W101/102
Level contact(s)

K101-104
Level contact(s) and
Pt100

W101/102
Level- and temperature
contact(s)

The standard assignment specified here applies to the max. number of contacts possible and contact function NO.

4 Bühler Technologies GmbH We reserve the right to amend specification. DE100209 ◦ 05/2024
Nivotemp NT 64, NT 64D
Technical Data NT 64D

Basic unit
Version MS VA Basic model
Operating pressure max. 1 bar max. 1 bar

12
Operating temperature -20 °C to +80 °C -20 °C to +80 °C
Float SK 610 SK 221
Min. fluid density 0.80 kg/dm³ with float 0.85 kg/dm³ with float

116
Lengths 280, 370, 500 mm (standard)
Material/Version

4
Display housing PA PA
Float rigid PU 1.4571 Gl cork
1st contact seal
Immersion tube Brass 1.4571
Flange (DIN 24557) PA PA

L2 = min. 80
L1 = min. 40
Contact spacing = min. 40 mm
Weight at L=280 mm approx. 300 g approx. 400 g

L
Each 100 mm add approx. 30 g approx. 50 g
Degree of protection IP65 IP65
Includes: SSR
Mounting screws (quantity 6) and rubberised cork seal. Stilling tube
with centring
last contact
Options disc
Stilling tube (SSR) Brass VA

min. 60
Temperature display electronics

5
Display 4 character 7 segment LED

3.5
Operation Via 3 keys Ø51 (MS)
Memory Min. / Max. Data memory Ø60.3 (VA)

Starting current input approx. 100 mA for 100 ms


Housing swivels 270°
Current input during operation approx. 50 mA (without current- and switching outputs)
Supply voltage (UB) 10 – 30 V DC (nominal voltage 24 V DC)
Ambient temperature -20 °C to +70°C
Display units Temperature °C / °F
Display range -20 °C to +120 °C
Alarm setting range 0 °C to 100 °C
Display accuracy ± 1 % from end value
Temperature sensor Pt100 Class B, Din EN 60751
Flange drawing
Level switching output K10
Max. number 2
6x Ø6

Function NC / NC*
Ø90
Ø73

Voltage max. 30 V DC
Switching current max. 0.5 A
Contact load max. 10 VA
Ø60
Min. contact spacing 40 mm
*NO= falling NC contact / NC = falling NO contact
SK 221 float for NT 64D-VA

last contact
min. 60

57

Ø51
3.5

min. Ø60
min. Ø61 with stilling tube

DE100209 ◦ 05/2024 We reserve the right to amend specification. Bühler Technologies GmbH 5
Nivotemp NT 64, NT 64D
Temperature outputs
Choose from the following temperature outputs

-2T -1T-KT -4T


Plug (base) 2 x M12 – 4-pin 2 x M12 – 4-pin 1 x M12 – 4-pin
1 x M12 – 8-pin
Switching outputs 2 x freely programmable* 1 x freely programmable* 4 x freely programmable
max. switching current** 0.5 A per output 0.5 A per output 0.5 A per output
continuous short-circuit continuous short-circuit continuous short-circuit
protected protected protected
Contact load max. 1 A total max. 1 A total max. 1 A total
Analogue output 1 x 4 – 20 mA, 2- 10 V
0-10 V, 0-5 V
Max. burden Ω = (UB -8 V) / 0.02 A
as current output
Min. input load 10 kΩ
as voltage output
Options
Stilling tube (SSR) Same material as immersion tube
*also programmable as frequency output
**Output 1 max. 0.2 A.

Ordering instructions NT 64D


Model key

NT 64D - - - - -nn - -nn- -


Type drawing, with display Temperature measurement
2T 2x PNP switching output
Version
MS Brass 4T 4x PNP switching output
VA float and VA immersion tube
Plug connector 1T-KT 1x PNP switching output
2xM12 1x analogue output
Length in mm Switching function 2nd contact
280
370 NO falling NC contact
500 NC falling NO contact
Level measurement 2nd level contact
1K 1x K10 nn Please specify installation
2K 2x K10 dimensions (L2 in mm)
Switching function 1st contact
1st level contact
NO falling NC contact
nn Please specify installation dimensions (L1 in mm)
NC falling NO contact

Accessories

Item no. 4-pin Item no. 8-pin Description


9144050010 9144050048 Connecting cable M12x1, 1.5 m, angular coupling and straight plug
9144050046 9144050049 Connecting cable M12x1, 3.0 m, angular coupling and straight plug
9144050047 9144050033 Connecting cable M12x1, 5.0 m, angular coupling and strands

Ordering example

You require: Level switch with flange, brass, plug connector S6, length L = 500 mm, 2 level contacts and temperature con-
tact TK 80 as NC contact, 1st contact 100 mm NC, 2nd contact 420 mm NO, with temperature display and
2 x programmable temperature output
Order: NT 64D-MS-2M12/500-2K-100NC-420NO-2T

6 Bühler Technologies GmbH We reserve the right to amend specification. DE100209 ◦ 05/2024
Nivotemp NT 64, NT 64D
Standard pin assignment NT 64D
Plug connection

2 x M12 (base)

Panel plug

Connection schematic Plug A Plug B


(level) (Temperature)

2T Pin
2 x temperature output 1 +24V DC
2 S2 (PNP)
3 GND
4 S1 (PNP)
1T-KT Pin
1 x Temperature output 1 +24 V DC
1 x Analogue output 2 Analogue (out)
3 GND
4 T1 (PNP)

Connection schematic

4T Pin
1 +24 V DC
2 S2 (PNP)
3 GND
4 x Temperature output
4 S1 (PNP)
5 S3 (PNP)
6 S4 (PNP)

DE100209 ◦ 05/2024 We reserve the right to amend specification. Bühler Technologies GmbH 7
Nivotemp NT 64, NT 64D
easyjust System

Contact strip with


10 (adjustability) cm scale

Pt100
Change the contact function NC/ Cordless (bistable) level contacts
NO by turning the contacts 180° Function: falling NO contact (NC) or falling
NC contact (NO)

Using adjustable level contacts allows the use of standardised immersion tube lengths for different size and shape oil tanks.
The switching points can always be configured to the specific system requirements without first having to purchase a specific
level switch.
This aids original equipment manufacturers and operators with project planning and logistics.
Since the level contacts are electric components, they require a connection to the respective circuits. This is typically achieved us-
ing cables which however, particularly in the case of multiple contacts, makes adjustments more difficult.
The Easy Just System is based on a wireless contact arrangement.
These are enclosed by different coloured housings and are arranged on a carrier board with gold contact points.
The different colours aid with coding the various contacts and ensure the terminal configuration matches the connectors.
The switching function of the contacts (NO or NC) is determined by turning the contact sleeve 180° on the carrier board.
Depending on the option selected, a fixed temperature switch (bi-metal, NO or NC), Pt 100 or 4-20 mA transmitter will be fixed
to the bottom end of the board for temperature monitoring.

8 Bühler Technologies GmbH We reserve the right to amend specification. DE100209 ◦ 05/2024