DE100209 NT 64 64D Easyjust
DE100209 NT 64 64D Easyjust
DE100209 NT 64 64D Easyjust
switch
Nivotemp NT 64, NT 64D Fluidcontrol
NT 64
NT 64D
Basic unit
Version MS VA Basic model
Operating pressure max. 1 bar max. 1 bar
Operating temperature -20 °C to +80 °C -20 °C to +80 °C
8 with VA stilling
G1 cork
65
Float SK 610 SK 221 seal
tube
Lengths 280, 370, 500 mm (standard)
L1 = min. 40
4
Material/Version
1st contact
Float rigid PU (SK 610) 1.4571 (SK 221)
L2 = min. 80
Flange (DIN 24557) PA PA
Weight at L=280 mm approx. 200 g approx. 300 g
L
Each 100 mm add approx. 30 g approx. 50 g
Includes:
Mounting screws (quantity 6) and rubberised cork seal. last
Ø50 (MS)
Ø60.3 (VA)
contact
Options
min. 60
Stilling tube (SSR) Brass VA
Level switching output K101-104 W101/102
Function NO/NC* Change-over contact
3.5
Ø44
Max. number 4 2
Voltage max. 30 V DC 30 V DC
Switching current max. 0.5 A 0.5 A Flange drawing
Contact load max. 10 VA 20 VA Ø60*
Min. contact spacing 40 mm 40 mm
*NO= falling NC contact/NC = falling NO contact
Optional temperature output
Ø90
Tolerance ±0.8 °C
57
Temperature transmitter KT
Temperature sensor Pt 100 Class B, DIN EN 60 751
3.5
Ø51
Measuring range 0 °C to +100 °C
Supply voltage (UB) 10 - 30 V DC
min. Ø60
Output 4 - 20 mA
min. Ø61 with stilling tube
Burden Ω max. =(UB -7.5 V)/0.02 A
* min. 80 with temperature
Accuracy ± 1 % from end value (in the medium)
Other measuring ranges available upon request
2 Bühler Technologies GmbH We reserve the right to amend specification. DE100209 ◦ 05/2024
Nivotemp NT 64, NT 64D
Ordering instructions NT 64
Model key
NT 64- - - -nn-nn- -
Model designation
Version
MS Brass
VA float / VA immersion tube Optional
Plug connector SSR Stilling tube
M3
S6
Temperature signal
M12
TK... NC contact NO contact
2M12
TK50NC TK50NO = 50 °C
Length in mm TK60NC TK60NO = 60 °C
280 TK70NC TK70NO = 70 °C
370 TK80NC TK80NO = 80 °C
500 Pt100 Temperature sensor
Level measurement KT Temperature transmitter
1-4 Number of contacts 1)
1) Please specify position and switching function per model
Level contacts key, example: L1 = nnnmm NC
K NC/NO
W change-over contact
Accessories
Ordering example
You require: Level switch with flange, brass, plug connector S6, length L = 500 mm, 2 level contacts and temperature contact
TK 80 as NC contact, 1st contact 100 mm NC, 2nd contact 420 mm NO
Order: NT 64-MS-S6-500-2K-TK80NC, L1=100 NC, L2=420 NO
Dimensions
DE100209 ◦ 05/2024 We reserve the right to amend specification. Bühler Technologies GmbH 3
Nivotemp NT 64, NT 64D
M3 S6 M12 (base) 2 x M12 (base)
6 3
2 1
1 2
PE PE
K101-104
Level contact(s)
W101/102
Level contact(s)
K101-104
Level contact(s) and
Pt100
W101/102
Level- and temperature
contact(s)
The standard assignment specified here applies to the max. number of contacts possible and contact function NO.
4 Bühler Technologies GmbH We reserve the right to amend specification. DE100209 ◦ 05/2024
Nivotemp NT 64, NT 64D
Technical Data NT 64D
Basic unit
Version MS VA Basic model
Operating pressure max. 1 bar max. 1 bar
12
Operating temperature -20 °C to +80 °C -20 °C to +80 °C
Float SK 610 SK 221
Min. fluid density 0.80 kg/dm³ with float 0.85 kg/dm³ with float
116
Lengths 280, 370, 500 mm (standard)
Material/Version
4
Display housing PA PA
Float rigid PU 1.4571 Gl cork
1st contact seal
Immersion tube Brass 1.4571
Flange (DIN 24557) PA PA
L2 = min. 80
L1 = min. 40
Contact spacing = min. 40 mm
Weight at L=280 mm approx. 300 g approx. 400 g
L
Each 100 mm add approx. 30 g approx. 50 g
Degree of protection IP65 IP65
Includes: SSR
Mounting screws (quantity 6) and rubberised cork seal. Stilling tube
with centring
last contact
Options disc
Stilling tube (SSR) Brass VA
min. 60
Temperature display electronics
5
Display 4 character 7 segment LED
3.5
Operation Via 3 keys Ø51 (MS)
Memory Min. / Max. Data memory Ø60.3 (VA)
Function NC / NC*
Ø90
Ø73
Voltage max. 30 V DC
Switching current max. 0.5 A
Contact load max. 10 VA
Ø60
Min. contact spacing 40 mm
*NO= falling NC contact / NC = falling NO contact
SK 221 float for NT 64D-VA
last contact
min. 60
57
Ø51
3.5
min. Ø60
min. Ø61 with stilling tube
DE100209 ◦ 05/2024 We reserve the right to amend specification. Bühler Technologies GmbH 5
Nivotemp NT 64, NT 64D
Temperature outputs
Choose from the following temperature outputs
Accessories
Ordering example
You require: Level switch with flange, brass, plug connector S6, length L = 500 mm, 2 level contacts and temperature con-
tact TK 80 as NC contact, 1st contact 100 mm NC, 2nd contact 420 mm NO, with temperature display and
2 x programmable temperature output
Order: NT 64D-MS-2M12/500-2K-100NC-420NO-2T
6 Bühler Technologies GmbH We reserve the right to amend specification. DE100209 ◦ 05/2024
Nivotemp NT 64, NT 64D
Standard pin assignment NT 64D
Plug connection
2 x M12 (base)
Panel plug
2T Pin
2 x temperature output 1 +24V DC
2 S2 (PNP)
3 GND
4 S1 (PNP)
1T-KT Pin
1 x Temperature output 1 +24 V DC
1 x Analogue output 2 Analogue (out)
3 GND
4 T1 (PNP)
Connection schematic
4T Pin
1 +24 V DC
2 S2 (PNP)
3 GND
4 x Temperature output
4 S1 (PNP)
5 S3 (PNP)
6 S4 (PNP)
DE100209 ◦ 05/2024 We reserve the right to amend specification. Bühler Technologies GmbH 7
Nivotemp NT 64, NT 64D
easyjust System
Pt100
Change the contact function NC/ Cordless (bistable) level contacts
NO by turning the contacts 180° Function: falling NO contact (NC) or falling
NC contact (NO)
Using adjustable level contacts allows the use of standardised immersion tube lengths for different size and shape oil tanks.
The switching points can always be configured to the specific system requirements without first having to purchase a specific
level switch.
This aids original equipment manufacturers and operators with project planning and logistics.
Since the level contacts are electric components, they require a connection to the respective circuits. This is typically achieved us-
ing cables which however, particularly in the case of multiple contacts, makes adjustments more difficult.
The Easy Just System is based on a wireless contact arrangement.
These are enclosed by different coloured housings and are arranged on a carrier board with gold contact points.
The different colours aid with coding the various contacts and ensure the terminal configuration matches the connectors.
The switching function of the contacts (NO or NC) is determined by turning the contact sleeve 180° on the carrier board.
Depending on the option selected, a fixed temperature switch (bi-metal, NO or NC), Pt 100 or 4-20 mA transmitter will be fixed
to the bottom end of the board for temperature monitoring.
8 Bühler Technologies GmbH We reserve the right to amend specification. DE100209 ◦ 05/2024