AU TEM0524 Rooftop Packaged Units Econex OPA250 2110 LR

Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

rbon ›

Ca F
e r

ut
Low

ure
ure

Low
ut

e
F r
Ca
rbon ›

AIR COOLED

Econex
Packaged Units

OPA 970 ~ OPA 2110


Scan to watch
product video

Econex, providing
leading efficiency
and sustainability

Heating Capacity
26.9kW - 194.8kW

Cooling Capacity
25.4kW - 202.7kW
OPA 970 ~ OPA 2110
Temperzone Air Cooled Packaged Units Introduction

Econex Packaged systems


offer a lower GWP solution
with superior efficiency.

From light to large commercial, Temperzone


can provide versatile air-cooled packaged
solutions for your buildings.

Energy efficient With the use of an inverter compressor technology the Econex Packaged 
comfort control unit range provides a precise load variation response and superior part
load performance for closer comfort control and higher energy efficiency.

71–81% reduction  Utilising R32 Refrigerant, Temperzone’s Econex Packaged units enables a 71–81%
in GWP reduction of Global Warming Potential (GWP) per kW of cooling when compared
to R410a units. Temperzone aspires to lead the commercial HVAC industry in
focusing to reduce the global warming potential of air conditioning products.

01 02
Temperzone Air Cooled Packaged Units Features

Features

OPA 970 ~ OPA 2110

Inverter Compressor EC Plug Fan EC Condenser Fans Econex Packaged units


Closely matching the High static plug fans that EC Condenser fans provide (25.4kW - 202.7kW)
performance to the load can be externally controlled greater efficiency and control
requirements during via 0~10VDC or BMS with soft starting and low 
all seasons command air noise

Dual EEV Systems Intelligent Unit Controller Wide Temperature


Dual EEV offers optimum Ensures the unit runs Operating Range
control of superheat for at its optimum efficiency From -15°C to +52°C* 
outstanding comfort and and provides system ambient
humidity control operation data

Corrosion Resistant Design Economy Cycle Low GWP Refrigerant


Marine grade surface Optional economy cycle R32 refrigerant has
protection and epoxy  and fresh air for reduced a significantly lower
coated coil protection power consumption in GWP than R410A
shoulder seasons

› Louvred guards
› 3rd party connectivity
› Filter rails
› Inbuilt Service GPO
› Easy maintenance access
› Foil face polyethylene New Compact Design New Intelligent De-ice BMS
insulation Reduced unit footprints for Quick & Efficient de-ice BACnet™ or Modbus via
easy and cost effective unit resulting in increased heating RS485 (or TCP/IP option)
* OPA 970 to 2110 placement performance *BACnet is optional accessory
from -10°C +50°C

03 04
Temperzone Air Cooled Packaged Units GWP

Lower Global Warming  Potential Carbon


Emissions attributed 
to refrigerant 
Potential Air Conditioning (CO2 Tonnes) OP
A

56
0 Reduced
5

0
45

77%

OPA 550

10
40
Older Model CO2
Tonnes

35

15
30
20 CO2 Tonnes
25

Econex
Lower global  With a smaller refrigerant charge and a GWP of 675*, OPA Econex R32
warming potential refrigerant units result in a 71-81% reduction in overall GWP per kW 
of cooling or heating when compared to R410A systems (GWP 2088*).
OPA 2 970
50
Reducing  As higher GWP refrigerants face increasing cost due to emissions tax
0 Reduced 0 Reduced
future costs levies the specification of R32 systems will represent a significant reduction 45 5
18
0 20

in the future costs associated with owning and maintaining these systems.
74% 78%

OPA 960
160
10

40
40
CO2 CO2
Tonnes Tonnes

140
35

15

60
30
20 CO2 Tonnes 0 2
80 CO2 Tonnes
25 100 1

4
29
OP

A
OP 17
94010
A3
5

0
0 Reduced 0 Reduced
5 0 20
45 18

71% 80%

OPA 960
160
10

40
40
CO2 CO2
Tonnes Tonnes

140
35

15

60
30
20 CO2 Tonnes 0 2
80 CO2 Tonnes
25 100 1

0
37
0 14
A
O PA OP

OPA 2110
45
0
0 Reduced 0 Reduced
5 0 20
45 18

81% 81%

160
10

40
40
CO2 CO2
Tonnes Tonnes

140
35

15

60
O PA 30
20 CO2 Tonnes 0 2
80 CO2 Tonnes
46 25 100 1

OP
5
21 0

0
A
00 21
A
OP

*AR4 Standard

05 06
Temperzone Air Cooled Packaged Units Inverter Compressors

Close Comfort Control Inverter 


Compressors
Econex inverter compressors only use the amount of energy to suit the operating
condition maximising your SEER performance.

› Soft starting, using much less  › Full inverter compressor range 


power at start up. from 16-100% compressor speed.
Econex Inverter compressor technology delivers › Matching capacity to load avoids  › Reduced amount of start/stop 
precise control of indoor air temperatures for superior temperature fluctuation and  for long life operation.
year round comfort with leading energy efficiency. reduces energy input power.

OFF ON OFF ON OFF ON OFF

Improved
Comfort Control

Inverter
Temperature

Fixed Speed

Set Point
Temperature

Time

Inverter Comfort  Fixed speed air conditioners are single speed on/off systems. Once the
Control desired temperature is reached, they turn off, turning back on only when the
temperature drops below or rises above a set level. This cycling between full
or no capacity causes unnecessary waste of electricity and doesn’t maintain
a constant room temperature.
The use of variable capacity inverter compressors allow a precise load
variation response for superior temperature control. The use of electronic
expansion valves and variable speed indoor and outdoor fans further allows
a more effective, and efficient, response to varying load conditions.
The OPA 960 to 2110 feature multiple refrigeration systems with inverter
and fixed speed compressors. The systems are staged so each fixed
speed system comes online as the inverter compressor reaches maximum
capacity, this enables variable capacity control and energy efficient
operation.

07 08
Temperzone Air Cooled Packaged Units SEER

Seasonal Energy Efficiency Total Cooling Seasonal


Performance Factor –
Commercial Cold Zone
(SEER) The Econex range, when
9
0
1 9
0
1

compared to the same

2
8

8
SEER SEER
(TCSPF) (TCSPF)
capacity fixed speed
Superior seasonal performance

7
3

3
units, has considerably
4 4

3
6 6

with Econex Inverter technology.

9
3.6
5 5

3.5
higher seasonal energy

ed
ed
6.

F ix
43

Fix
efficiency factors. OP 4.7
1
A
25
0 3 50
O PA

Fixed Speed

300 15
Econex OPA 560 0 0
Econex 9 1 9 1
Variable Speed vs Fix 14

Speed – Commercial 13

2
8

8
SEER SEER
250 (TCSPF) (TCSPF)
Cold Zone 12

7
3

3
2

2
3.3

3.4
d
11

ed
4 4

F ixe
6 6
5 5

Fix
200 10
EER Econex 9
Bin Hours Qty.

5.20 5.22
Variable Speed
8

EER
150 O PA 4 50 O PA 5 6 0
7
6
EER Fixed Speed
100 5
T1
4
Annual Cooling kWh –
3
Climate Bin Hours  50 Commercial Cold Zone
2

OP
– Cold Zone
MEPS Seasonal

A2
1

278

50
performance energy

0
0 0 Annual Cooling Annual Cooling
usages for Econex range kWh kWh
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
shows considerable
Ambient (°C)
energy savings (kWh)

33
compared to fixed

49
8

9
Seasonal energy efficiency requires testing of units at “part load”, as well 53

d
speed equivalents.

0
xe
7069

35
Fi
A
as traditional T1 & H1 conditions. Data is then mapped against the bin OP
operating hours for the corresponding temperate zone to determine F ixe d

seasonal energy performance.


Fixed Speed
› Units operate the majority of the time at part load.

ed
› Inverter compressors are more efficient at part load.

Fix
9

41
› Variable speed fans are more efficient at part load.

11
Econex
MEPS EER condition (T1) is a single point where units rarely operate. SEER Annual Cooling Annual Cooling
kWh kWh

9398
goes a step further to estimate real use, overlaying the “bin hours” shows

F ixe d
actual efficiency is better for variable speed systems.
Compared to the same capacity fixed speed unit, the Econex OPA 560
74
considerably increases in efficiency (EER) as the ambient reduces, 607
2 76

while the fixed speeds system efficiency remains relatively unchanged. 4 50 OP


A 56
O PA 0

09 10
Temperzone Air Cooled Packaged Units Energy Saving Technology

Energy Saving Technology

Intelligent system control technology offers 


leading energy efficiency with precision control 
of the air conditioners refrigeration system.

EC Fan  Our high-efficiency EC fan motors are up to 50% more energy efficient
Technology than Belt drive or AC motor alternatives and enable quiet operation
with slow ramp-up and no sudden noise changes. Achieve precise comfort
with c
 ustom select fan speeds or continuously variable fan speed control.

100

AC Motor 90

80

70
EC Motor
Input Power (%)

60

50

40

30

20

10

0
0 10 20 30 40 50 60 70 80 90 100
EC Plug Fans EC Plug fans control airflow accurately and efficiently.
Air Flow (%)
Fan speed can also be controlled via external signals via input or Modbus.

Ideal solution › Programmable for exact airflow.


for open spaces › High static pressure.
› Enables variable airflow operation.
› Longer motor life resulting from lower running temperatures.
› Lower maintenance and commissioning costs.
› Slow ramp up for quiet operation.
› Longer bearing life due to soft start.

EC Condenser Fans EC fans increase overall efficiency. Infinitely variable fan speed control
means refrigeration efficiency can be optimised in all climatic conditions.
› Up to 50% more efficient than AC fan technology.
› High static pressure.
› Minimised power consumption under optimised.
floating head pressure control.
› Quiet operation mode.

11 12
Temperzone Air Cooled Packaged Units Dual EEV

High Performance Design Electronic Expansion


Valves (EEV)
Extra capacity with For versatile specification, all R32 inverter packaged systems offer a very wide
very wide heating heating and cooling capacity range enabling reliable comfort at times of peak
and cooling ranges load and increased energy savings under low load conditions.

Electronic Expansion Valves (EEV’s) optimise refrigeration systems ensuring


OPA 350 Capacity Range the evaporator coil is fully utilised at all times which leads to increased energy
savings. In addition, the discharge pressures can be lowered based on ambient
conditions by simply increasing the speed of the EC condenser fans leading to
even higher savings.
Heating 13.9kW 37.0kW
rated
47.0kW +27%
capacity

Cooling 18.0kW 34.8kW


rated
45.4kW +30% Accurator
capacity

14 18 22 26 30 34 38 42 46 EEV

Efficiency
Capacity (kW)

Extreme weather Designed for the harshest conditions these R32 packaged units are designed to
operation operate in ambient temperatures from -15°C to 52°C* to ensure you’re always
comfortable, whatever the weather. (*OPA 970 to 2110: -10°C to 50°C)
27°C 23°C 19°C
Ambient temperature

Heating Down to -15°C* ambient Up to +52°C* ambient Cooling


Benefits Include:
› EEV’s enable improved efficiency and reduced
operating costs at part-load conditions.
› They also facilitate maximised energy savings
during the shoulder seasons – periods in which
air conditioning systems often run at part-load.

13 14
Temperzone Air Cooled Packaged Units Intelligent De-ice

Advanced & Super Dry Mode Intelligent De-ice

Econex offers superior levels of Dry Modes  New intelligent de-ice enables improved heating
to suit your requirements. performance in colder conditions. Optimised coil 
circuitry and new controller logic results in fast 
and more effective de-ice.

Econex de-ice is designed to support the full turn down of the compressor 
and de-ices from the top to the bottom of full height coil circuits. Utilising
a highly balanced split circuit coil design prevents excess pressure drop 
as the refrigerant changes phase.
Super Dry Mode

Allows:
Advanced Dry Mode › Capacity during de-ice to be controlled › Operation is extended up to 50 minute
Moisture Removal (%)

to 10°C condensing temps. intervals between de-ice cycles,


up from 35 min.
› Aim to melt ice, not evaporate water.
Standard Mode Evaporatingwater requires 6.75 more › Better capacity control allows better room
energy than melting ice. temp control under part load conditions.

› Econex de-ice at a low capacity which


is more efficient, and takes similar time
as traditional de-ice.

100 75 50

Unit Capacity (%)

Advanced Dry Mode and Super Dry Mode can only be achieved by Temperzone
Econex units as they utilise optimised Dual Electronic Refrigeration Valve control
(IP protected) to achieve exceptional dehumidification performance across the
units full operation range.
Advanced dry mode can provide de-humidification over a wide range of operating
conditions and unit duty whilst the indoor fan speed can remain constant.
Super dry cooling mode requires the UC8 controller to vary the indoor fan speed.
Under most operating conditions indoor fan speed will be equal to the speed
requested by the thermostat or other controller. Only when the desired indoor coil
temperature cannot be achieved by the dual electronic expansion valves alone
then the controller will adjust the indoor fan speed to obtain de-humidification.

15 16
Temperzone Air Cooled Packaged Units Durable Design

Durable Long Life Design 1

Epoxy coated coil


2

Marine grade pretreatment


3

Louvre Guards for added


protection for superior and polyester powder protection against severe
corrosion resistance coated galvanised steel, weather, UV damage to 
inside and out coils & accidental contact

Econex units are designed to be highly durable 


4 5 6
and suited to the harshest environmental conditions.
Sloped outdoor section allows SKT coated screws provide Remove bungs to create
water from rain and de-ice to a higher corrosion resistance positive pressure electrical
Adaptive Valve Temperzone’s proprietary Adaptive Valve Regulation system (AVR) ensures that be drained from the unit than 316 stainless steel compartment and clear dust

Regulation Temperzone inverter air conditioning systems run more efficiently and enjoy a
longer operational life. AVR maximises efficiency in both heating and cooling 7 8
cycles by regulating refrigerant flow capacity, allowing the system to maintain
Closed cell foam insulation Isolated compressor and
stability and efficiency over the full range of operating conditions.
ensuring no particles are electrical compartment for
introduced into the air stream less noise and weatherproofing
Starving

Starving
(Traditional
Underdamped) 5

Ideal (AVR)
Optimum

Prolonged 6
Flooding 2 1
(Traditional 
Overdamped)
Flooding

7
3

Start

8
AVR also prevents:
4
› Prolonged flooding (oil washed out of the system), which leads
to seized bearings and compressor damage.
› Improves Compressor Life cycle.
› Starving, which leads to HP/LP trips and reduced EER / Duty.
Continuous starving leads to compressor motor overheat.

17 18
Temperzone Air Cooled Packaged Units BMS Connectivity

Control Options BMS Connectivity

From advanced commercial controllers to stylish Econex Packaged units can connect
touch screen controllers, Temperzone has a control into a BMS for control and operation.
option to suit your space and application.
TZT-100 Temperzone’s TZT-100 thermostat › Through the outdoor unit via the › Daisy chain wiring saves on amount
is an advanced controller suited to UC8’s Modbus/RS485 port with of wiring and required labour time.
commercial environments. It delivers multi-unit control capability.
› BMS communication cable
comprehensive control for your system
› Up to 99 units can be connected (2-wire shielded).
not available with other thermostats.
on a common RS458 bus in daisy
› Maximum cable length of 1000m.
chain design.

Features

Modes – cool / cool-dry / heat / auto-dry / auto Programmable occupancy inputs

Set airflow - auto / low / med / hi (customisable) On demand override count down timer up to 12hrs

Key board and temperature locks Filter monitor option (by hours)

7 Day programmable time clock Continuous or Intermittent fan operation

Set temperature: 5°C to 50°C at 0.5°C increments Connects to outdoor unit (UC8)

Remote sensor inputs

Simplified BMS Integration


with Modbus or BACnet BMS
Communication Protocol.

19 20
Temperzone Air Cooled Packaged Units Easy Installation & Maintenance

Minimised Footprint Easy Installation


& Maintenance
Unit footprints have been minimised to reduce associated While simplicity of design enables quick and easy
installation costs and accommodate confined spaces. installation, in-built functionalities mean that after-sales
operation and servicing is also a time-efficient process.
Footprint Econex footprint sizes have been reduced considerably. This amounts to between
Reduction 20% to 22% for the Econex OPA 350 to 560, and 10% to 16% for the Econex 1410
and 2110 when compared to the previous generation product.

1 2 3

Removable access cover Easy wiring terminal connections Socket Outlet (SO)
OPA 350
for inspection of outdoor for communications and in electrical panel for
coil headers and sensors mains wiring single phase appliances

OPA 370
4 5 6

OPA 450 Generic mechanical and Optional drain cups with spigots Access covers for
electrical parts for easy for PVC pipe connections for indoor coil inspection
servicing and replacement remote drainage and drain tray cleaning
OPA 465

7 8 9

OPA 560 UC8 7-segment fault display Easy access hinged Deep and wide Indoor coil
In-built electronic safeties maintenance service drain tray with brass hex
Adjustable indoor airflow doors with door stays socket removal connection
OPA 550

10 11 12

Four 16mm unit mounting Easy access design with Easy filter access through
holes in cross channels spacious access to refrigerant supply air chamber
OPA 1410 OPA 2110 components for servicing hinged service door

OPA 1400 OPA 2100

Wiring is made easy and convenient with new client


wiring terminals.
Convenient Client Installer electrical access has been
Wiring Terminals improved with connections more
easily accessed through customer
terminals. Units are fully wired and
the main power supply along with
communication connections can
be wired directly within the terminal.

21 22
Temperzone Air Cooled Packaged Units Flexible Handing Options

Flexible Handing Options


Econex units offer flexible handing configurations
as standard to suit site requirements.

Standard units are supplied with left hand supply air (when facing the spigots).
Alternative configurations for supply air and return air openings are shown in
tables on the following page.

Standard Hand
Horizontal Discharge
Economiser Cycle option
Downward Discharge
The Economy Cycle presents
significant energy savings. Side Discharge
When the outside ambient air Top Discharge
is below set point required, the
compressor is cycled off, outside
air dampers open, and the supply
air fan continues to run, bringing
cool air in from outside.

High Static EC Outdoor Fans


The OPA 250 – 560 & 970 high static
outdoor fans allows at least 125pa*
allowing condenser air to be ducted
in applications where the unit is
Opposite Hand
positioned inside.
*OPA 1410 & 2110 maximum 120Pa
Horizontal Discharge
Downward Discharge
Side Discharge
UC8 intelligent Intelligent unit controller (UC8) has been designed to deliver efficient and precise
Top Discharge
unit controller system control under all conditions. Intelligent control of outdoor fan speed, coil
temperatures, inverter compressor speed and advanced refrigeration safeties.

WiFi Service WiFi Service Utility (WSU) is a portable control interface that plugs directly into
Utility Tool the UC8 board on a Temperzone Air Conditioning Unit. It allows you to monitor a
wide range of operational parameters, view fault logs and even take control of the
unit. It has its own WiFi network built in and the control and diagnostics are done
wirelessly from a smartphone, tablet or notebook PC.

23 24
Temperzone Air Cooled Packaged Units Flexible Handing Options

Flexible Handing Options


Right Hand
Configuration
(Opposite Hand)
OPA 250 to 2110 offer flexible handing configurations
available to suit the application.

Standard units are supplied with left hand supply air (when facing the spigots).
Alternative configurations for supply air and return air openings are shown in the
below tables.

Configuration Return Air - Without Economiser


Without Economiser
Top Front Down Side

Top
• • • •
• • • • Left Hand
Supply Air

Front
Configuration
Down
• • • • (Standard Hand)

Side
• • • •
All options are available in standard or opposite hand configuration

Configuration Return Air - With Economiser


With Economiser
Top Front Down Side

Top
• • •
• • •
Supply Air

Front

Down
• • • Optional parts › Filters - rated EU4/G4 disposable
Side
• • • › Economy dampers
› Economy cycle control
All options are available in standard or opposite hand configuration › Supply and return air handings

25 26
Temperzone Air Cooled Packaged Units Econex OPA Specifications

Econex
OPA Specifications

OPA 970 ~ OPA 2110

Model OPA 250 OPA 350 OPA 450 OPA 560 OPA 970 OPA 1410 OPA 2110 Model OPA 250 OPA 350 OPA 450 OPA 560 OPA 970 OPA 1410 OPA 2110

Total (Gross) Capacity kW * Compressor

Inverter x1,
Cooling 25.4 (10.1~29.1) 35.9 (18~45.4) 44.9 (18.2~52.4) 55.6 (27.4~64.8) 92.5 (15.4~99.2) 145.7 (15.9~155.4) 202.7(32.1~208.8) Type Inverter Scroll x1 Inverter x1, Fixed x3
Fixed x1
Refrigerant R32
Nett (Rated) Capacity kW *

Cooling 24.6 34.8 43.3 53.5 88.9 140.2 193.8 Fans

Heating 26.9 (6.5~29.3) 37.0 (13.9~47.0) 44.4 (16.5~54.5) 57.0 (24.0~63.1) 88.2 (14.3~96.1) 142.1 (12.9~151.2) 194.8(14.9~205.9) Indoor EC Plug Fan x1 EC Plug Fan x2 EC Plug Fan x4

Outdoor EC Axial x1 EC Axial x2


SEER*

TCSPF* (Cold/Mixed/Hot) 6.43/5.41/4.73 4.71/5.60/4.85 5.20/4.56/4.34 5.22/4.60/4.21 3.39/3.24/3.26 3.50/3.34/3.41 4.24/3.83/3.76 Airflow (l/s)

Nominal** 1250 1800 2200 2600 4800 8100 11000


EER/COP *
Max.@2.5 m/s
face velocity 1970 2450 2900 3610 5800 8100 11000

EER / AEER * Cooling 3.20 / 3.18 3.15 / 3.14 2.99 / 2.98 2.99 / 2.98 2.97 / 2.96 3.05 / 3.04 3.00 / 2.99
Noise Data***
COP / ACOP * Heating 3.33 / 3.31 3.21 / 3.19 3.14 / 3.13 2.98 / 2.97 3.35 / 3.34 3.59 / 3.58 3.53 / 3.51

SPL @ 3 Metres (dBA) 58 62 64 67 76 68 73


Power

Overall Dimensions (mm)


Power Supply 3 Phase 400 V a.c. 50 Hz + N + E
Run Amps / Phase 1795 1795 2330
(A/ph.)
12.5/11.5/13 17.5/15.5/19.5 24/22/24 28/26/29 46/43/46 72/74/74 108/108/110 Length 2330 2898 4500 5000

Width 1530 1530 1530 1530 2151 2325 2300


Unit Controllers
Height 1545 1850 1500 1805 2258 2348 2648

Controller UC8 (x1) UC8 (x2) UC8 (x4)

Weight (kg)

Ambient Operating Range


Nett 511 596 643 759 1270 2064 2577
Cooling / Heating (°C) -10 ~ 52 / -15 ~ 25 -10 ~ 50 / -10 ~ 25

Notes: * To AS/NZS 3823 conditions


** Supply Airflow at Nominal Conditions
*** Noise Data measured to EN 12102‑1:2017 - measured in decibels re 1 picowatt
**** Units comply with MEPS & or the requirements on the NCC

27 28
OPA 970 ~ OPA 2110

temperzone.com Australia
Sydney 02 – 8822 5700
Adelaide 08 – 8115 2 111
Brisbane 07 – 3308 8333
Australia
Melbourne 03 – 8769 7600
sydsales@temperzone.com
sasales@temperzone.com
Distributors
qldsales@temperzone.com
Newcastle 02 – 4962 1155
vicsales@temperzone.com
Perth 08 – 6399 5900
New Zealand Launceston 03 – 6331 4209
nzsales@temperzone.com
New Zealand
Singapore Auckland 09 – 279 5250
sales@temperzone.com.sg Hamilton 07 – 839 2705
Wellington 04 – 569 3262
Christchurch 03 – 379 3216
The specifications of this catalogue may change
without prior notice to allow Temperzone to
incorporate the latest innovations for its customers. Asia
The information contained in the catalogue is merely Singapore 65 – 6733 4292
informative. Temperzone declines any responsibility
in the broadest sense, for damage direct or indirect, Shanghai 21 – 5648 2078
arising from the use and / or interpretation of the
recommendations in this catalogue.