Econex
Packaged Units
Econex, providing
leading efficiency
and sustainability
Heating Capacity
26.9kW - 194.8kW
Cooling Capacity
25.4kW - 202.7kW
OPA 970 ~ OPA 2110
Temperzone Air Cooled Packaged Units Introduction
Energy efficient With the use of an inverter compressor technology the Econex Packaged
comfort control unit range provides a precise load variation response and superior part
load performance for closer comfort control and higher energy efficiency.
71–81% reduction Utilising R32 Refrigerant, Temperzone’s Econex Packaged units enables a 71–81%
in GWP reduction of Global Warming Potential (GWP) per kW of cooling when compared
to R410a units. Temperzone aspires to lead the commercial HVAC industry in
focusing to reduce the global warming potential of air conditioning products.
01 02
Temperzone Air Cooled Packaged Units Features
Features
› Louvred guards
› 3rd party connectivity
› Filter rails
› Inbuilt Service GPO
› Easy maintenance access
› Foil face polyethylene New Compact Design New Intelligent De-ice BMS
insulation Reduced unit footprints for Quick & Efficient de-ice BACnet™ or Modbus via
easy and cost effective unit resulting in increased heating RS485 (or TCP/IP option)
* OPA 970 to 2110 placement performance *BACnet is optional accessory
from -10°C +50°C
03 04
Temperzone Air Cooled Packaged Units GWP
56
0 Reduced
5
0
45
77%
OPA 550
10
40
Older Model CO2
Tonnes
35
15
30
20 CO2 Tonnes
25
Econex
Lower global With a smaller refrigerant charge and a GWP of 675*, OPA Econex R32
warming potential refrigerant units result in a 71-81% reduction in overall GWP per kW
of cooling or heating when compared to R410A systems (GWP 2088*).
OPA 2 970
50
Reducing As higher GWP refrigerants face increasing cost due to emissions tax
0 Reduced 0 Reduced
future costs levies the specification of R32 systems will represent a significant reduction 45 5
18
0 20
in the future costs associated with owning and maintaining these systems.
74% 78%
OPA 960
160
10
40
40
CO2 CO2
Tonnes Tonnes
140
35
15
60
30
20 CO2 Tonnes 0 2
80 CO2 Tonnes
25 100 1
4
29
OP
A
OP 17
94010
A3
5
0
0 Reduced 0 Reduced
5 0 20
45 18
71% 80%
OPA 960
160
10
40
40
CO2 CO2
Tonnes Tonnes
140
35
15
60
30
20 CO2 Tonnes 0 2
80 CO2 Tonnes
25 100 1
0
37
0 14
A
O PA OP
OPA 2110
45
0
0 Reduced 0 Reduced
5 0 20
45 18
81% 81%
160
10
40
40
CO2 CO2
Tonnes Tonnes
140
35
15
60
O PA 30
20 CO2 Tonnes 0 2
80 CO2 Tonnes
46 25 100 1
OP
5
21 0
0
A
00 21
A
OP
*AR4 Standard
05 06
Temperzone Air Cooled Packaged Units Inverter Compressors
Improved
Comfort Control
Inverter
Temperature
Fixed Speed
Set Point
Temperature
Time
Inverter Comfort Fixed speed air conditioners are single speed on/off systems. Once the
Control desired temperature is reached, they turn off, turning back on only when the
temperature drops below or rises above a set level. This cycling between full
or no capacity causes unnecessary waste of electricity and doesn’t maintain
a constant room temperature.
The use of variable capacity inverter compressors allow a precise load
variation response for superior temperature control. The use of electronic
expansion valves and variable speed indoor and outdoor fans further allows
a more effective, and efficient, response to varying load conditions.
The OPA 960 to 2110 feature multiple refrigeration systems with inverter
and fixed speed compressors. The systems are staged so each fixed
speed system comes online as the inverter compressor reaches maximum
capacity, this enables variable capacity control and energy efficient
operation.
07 08
Temperzone Air Cooled Packaged Units SEER
2
8
8
SEER SEER
(TCSPF) (TCSPF)
capacity fixed speed
Superior seasonal performance
7
3
3
units, has considerably
4 4
3
6 6
9
3.6
5 5
3.5
higher seasonal energy
ed
ed
6.
F ix
43
Fix
efficiency factors. OP 4.7
1
A
25
0 3 50
O PA
Fixed Speed
300 15
Econex OPA 560 0 0
Econex 9 1 9 1
Variable Speed vs Fix 14
Speed – Commercial 13
2
8
8
SEER SEER
250 (TCSPF) (TCSPF)
Cold Zone 12
7
3
3
2
2
3.3
3.4
d
11
ed
4 4
F ixe
6 6
5 5
Fix
200 10
EER Econex 9
Bin Hours Qty.
5.20 5.22
Variable Speed
8
EER
150 O PA 4 50 O PA 5 6 0
7
6
EER Fixed Speed
100 5
T1
4
Annual Cooling kWh –
3
Climate Bin Hours 50 Commercial Cold Zone
2
OP
– Cold Zone
MEPS Seasonal
A2
1
278
50
performance energy
0
0 0 Annual Cooling Annual Cooling
usages for Econex range kWh kWh
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
shows considerable
Ambient (°C)
energy savings (kWh)
33
compared to fixed
49
8
9
Seasonal energy efficiency requires testing of units at “part load”, as well 53
d
speed equivalents.
0
xe
7069
35
Fi
A
as traditional T1 & H1 conditions. Data is then mapped against the bin OP
operating hours for the corresponding temperate zone to determine F ixe d
ed
› Inverter compressors are more efficient at part load.
Fix
9
41
› Variable speed fans are more efficient at part load.
11
Econex
MEPS EER condition (T1) is a single point where units rarely operate. SEER Annual Cooling Annual Cooling
kWh kWh
9398
goes a step further to estimate real use, overlaying the “bin hours” shows
F ixe d
actual efficiency is better for variable speed systems.
Compared to the same capacity fixed speed unit, the Econex OPA 560
74
considerably increases in efficiency (EER) as the ambient reduces, 607
2 76
09 10
Temperzone Air Cooled Packaged Units Energy Saving Technology
EC Fan Our high-efficiency EC fan motors are up to 50% more energy efficient
Technology than Belt drive or AC motor alternatives and enable quiet operation
with slow ramp-up and no sudden noise changes. Achieve precise comfort
with c
ustom select fan speeds or continuously variable fan speed control.
100
AC Motor 90
80
70
EC Motor
Input Power (%)
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
EC Plug Fans EC Plug fans control airflow accurately and efficiently.
Air Flow (%)
Fan speed can also be controlled via external signals via input or Modbus.
EC Condenser Fans EC fans increase overall efficiency. Infinitely variable fan speed control
means refrigeration efficiency can be optimised in all climatic conditions.
› Up to 50% more efficient than AC fan technology.
› High static pressure.
› Minimised power consumption under optimised.
floating head pressure control.
› Quiet operation mode.
11 12
Temperzone Air Cooled Packaged Units Dual EEV
14 18 22 26 30 34 38 42 46 EEV
Efficiency
Capacity (kW)
Extreme weather Designed for the harshest conditions these R32 packaged units are designed to
operation operate in ambient temperatures from -15°C to 52°C* to ensure you’re always
comfortable, whatever the weather. (*OPA 970 to 2110: -10°C to 50°C)
27°C 23°C 19°C
Ambient temperature
13 14
Temperzone Air Cooled Packaged Units Intelligent De-ice
Econex offers superior levels of Dry Modes New intelligent de-ice enables improved heating
to suit your requirements. performance in colder conditions. Optimised coil
circuitry and new controller logic results in fast
and more effective de-ice.
Econex de-ice is designed to support the full turn down of the compressor
and de-ices from the top to the bottom of full height coil circuits. Utilising
a highly balanced split circuit coil design prevents excess pressure drop
as the refrigerant changes phase.
Super Dry Mode
Allows:
Advanced Dry Mode › Capacity during de-ice to be controlled › Operation is extended up to 50 minute
Moisture Removal (%)
100 75 50
Advanced Dry Mode and Super Dry Mode can only be achieved by Temperzone
Econex units as they utilise optimised Dual Electronic Refrigeration Valve control
(IP protected) to achieve exceptional dehumidification performance across the
units full operation range.
Advanced dry mode can provide de-humidification over a wide range of operating
conditions and unit duty whilst the indoor fan speed can remain constant.
Super dry cooling mode requires the UC8 controller to vary the indoor fan speed.
Under most operating conditions indoor fan speed will be equal to the speed
requested by the thermostat or other controller. Only when the desired indoor coil
temperature cannot be achieved by the dual electronic expansion valves alone
then the controller will adjust the indoor fan speed to obtain de-humidification.
15 16
Temperzone Air Cooled Packaged Units Durable Design
Regulation Temperzone inverter air conditioning systems run more efficiently and enjoy a
longer operational life. AVR maximises efficiency in both heating and cooling 7 8
cycles by regulating refrigerant flow capacity, allowing the system to maintain
Closed cell foam insulation Isolated compressor and
stability and efficiency over the full range of operating conditions.
ensuring no particles are electrical compartment for
introduced into the air stream less noise and weatherproofing
Starving
Starving
(Traditional
Underdamped) 5
Ideal (AVR)
Optimum
Prolonged 6
Flooding 2 1
(Traditional
Overdamped)
Flooding
7
3
Start
8
AVR also prevents:
4
› Prolonged flooding (oil washed out of the system), which leads
to seized bearings and compressor damage.
› Improves Compressor Life cycle.
› Starving, which leads to HP/LP trips and reduced EER / Duty.
Continuous starving leads to compressor motor overheat.
17 18
Temperzone Air Cooled Packaged Units BMS Connectivity
From advanced commercial controllers to stylish Econex Packaged units can connect
touch screen controllers, Temperzone has a control into a BMS for control and operation.
option to suit your space and application.
TZT-100 Temperzone’s TZT-100 thermostat › Through the outdoor unit via the › Daisy chain wiring saves on amount
is an advanced controller suited to UC8’s Modbus/RS485 port with of wiring and required labour time.
commercial environments. It delivers multi-unit control capability.
› BMS communication cable
comprehensive control for your system
› Up to 99 units can be connected (2-wire shielded).
not available with other thermostats.
on a common RS458 bus in daisy
› Maximum cable length of 1000m.
chain design.
Features
Set airflow - auto / low / med / hi (customisable) On demand override count down timer up to 12hrs
Key board and temperature locks Filter monitor option (by hours)
Set temperature: 5°C to 50°C at 0.5°C increments Connects to outdoor unit (UC8)
19 20
Temperzone Air Cooled Packaged Units Easy Installation & Maintenance
1 2 3
Removable access cover Easy wiring terminal connections Socket Outlet (SO)
OPA 350
for inspection of outdoor for communications and in electrical panel for
coil headers and sensors mains wiring single phase appliances
OPA 370
4 5 6
OPA 450 Generic mechanical and Optional drain cups with spigots Access covers for
electrical parts for easy for PVC pipe connections for indoor coil inspection
servicing and replacement remote drainage and drain tray cleaning
OPA 465
7 8 9
OPA 560 UC8 7-segment fault display Easy access hinged Deep and wide Indoor coil
In-built electronic safeties maintenance service drain tray with brass hex
Adjustable indoor airflow doors with door stays socket removal connection
OPA 550
10 11 12
Four 16mm unit mounting Easy access design with Easy filter access through
holes in cross channels spacious access to refrigerant supply air chamber
OPA 1410 OPA 2110 components for servicing hinged service door
21 22
Temperzone Air Cooled Packaged Units Flexible Handing Options
Standard units are supplied with left hand supply air (when facing the spigots).
Alternative configurations for supply air and return air openings are shown in
tables on the following page.
Standard Hand
Horizontal Discharge
Economiser Cycle option
Downward Discharge
The Economy Cycle presents
significant energy savings. Side Discharge
When the outside ambient air Top Discharge
is below set point required, the
compressor is cycled off, outside
air dampers open, and the supply
air fan continues to run, bringing
cool air in from outside.
WiFi Service WiFi Service Utility (WSU) is a portable control interface that plugs directly into
Utility Tool the UC8 board on a Temperzone Air Conditioning Unit. It allows you to monitor a
wide range of operational parameters, view fault logs and even take control of the
unit. It has its own WiFi network built in and the control and diagnostics are done
wirelessly from a smartphone, tablet or notebook PC.
23 24
Temperzone Air Cooled Packaged Units Flexible Handing Options
Standard units are supplied with left hand supply air (when facing the spigots).
Alternative configurations for supply air and return air openings are shown in the
below tables.
Top
• • • •
• • • • Left Hand
Supply Air
Front
Configuration
Down
• • • • (Standard Hand)
Side
• • • •
All options are available in standard or opposite hand configuration
Top
• • •
• • •
Supply Air
Front
Down
• • • Optional parts › Filters - rated EU4/G4 disposable
Side
• • • › Economy dampers
› Economy cycle control
All options are available in standard or opposite hand configuration › Supply and return air handings
25 26
Temperzone Air Cooled Packaged Units Econex OPA Specifications
Econex
OPA Specifications
Model OPA 250 OPA 350 OPA 450 OPA 560 OPA 970 OPA 1410 OPA 2110 Model OPA 250 OPA 350 OPA 450 OPA 560 OPA 970 OPA 1410 OPA 2110
Inverter x1,
Cooling 25.4 (10.1~29.1) 35.9 (18~45.4) 44.9 (18.2~52.4) 55.6 (27.4~64.8) 92.5 (15.4~99.2) 145.7 (15.9~155.4) 202.7(32.1~208.8) Type Inverter Scroll x1 Inverter x1, Fixed x3
Fixed x1
Refrigerant R32
Nett (Rated) Capacity kW *
Heating 26.9 (6.5~29.3) 37.0 (13.9~47.0) 44.4 (16.5~54.5) 57.0 (24.0~63.1) 88.2 (14.3~96.1) 142.1 (12.9~151.2) 194.8(14.9~205.9) Indoor EC Plug Fan x1 EC Plug Fan x2 EC Plug Fan x4
TCSPF* (Cold/Mixed/Hot) 6.43/5.41/4.73 4.71/5.60/4.85 5.20/4.56/4.34 5.22/4.60/4.21 3.39/3.24/3.26 3.50/3.34/3.41 4.24/3.83/3.76 Airflow (l/s)
EER / AEER * Cooling 3.20 / 3.18 3.15 / 3.14 2.99 / 2.98 2.99 / 2.98 2.97 / 2.96 3.05 / 3.04 3.00 / 2.99
Noise Data***
COP / ACOP * Heating 3.33 / 3.31 3.21 / 3.19 3.14 / 3.13 2.98 / 2.97 3.35 / 3.34 3.59 / 3.58 3.53 / 3.51
Weight (kg)
27 28
OPA 970 ~ OPA 2110
temperzone.com Australia
Sydney 02 – 8822 5700
Adelaide 08 – 8115 2 111
Brisbane 07 – 3308 8333
Australia
Melbourne 03 – 8769 7600
sydsales@temperzone.com
sasales@temperzone.com
Distributors
qldsales@temperzone.com
Newcastle 02 – 4962 1155
vicsales@temperzone.com
Perth 08 – 6399 5900
New Zealand Launceston 03 – 6331 4209
nzsales@temperzone.com
New Zealand
Singapore Auckland 09 – 279 5250
sales@temperzone.com.sg Hamilton 07 – 839 2705
Wellington 04 – 569 3262
Christchurch 03 – 379 3216
The specifications of this catalogue may change
without prior notice to allow Temperzone to
incorporate the latest innovations for its customers. Asia
The information contained in the catalogue is merely Singapore 65 – 6733 4292
informative. Temperzone declines any responsibility
in the broadest sense, for damage direct or indirect, Shanghai 21 – 5648 2078
arising from the use and / or interpretation of the
recommendations in this catalogue.
TEM05/24