DSC N-650
Differential Scanning Calorimeter

Description

Differential Scanning Calorimeter (DSC) is a powerful


technique that measures the energy absorbed or
released as a function of time and temperature. The
sensor of DSC is the heat flux plate which is designed
to give superior performance and rugged reliability. The
heat flux plate is capable of measuring small energy
changes. Examples of measurements with DSC are Melt
enthalpy, Glass transition, Heat of crystallization and
Purity determination.

The DSC has been developed in conjunction with the


powerful software to provide superior performance. This
new instrument has been designed from the ground up
to offer years of reliable and accurate data. Thermosets,
Thermoplastics, Composite, Pharmaceuticals, Binders
and Building materials are examples of some of the
materials tested with DSC.

Applications
 Glass transition  Rate of cure
 Melting points  Oxidative stability
 Crystallization time and temperature  Heat of fusion
 Boiling points  Heat of reactions
 Thermal stability  Heat capacity
 Purity  Effects of additives
 Degree of cure  Polymer blends
 Effect of recycled materials

Modified PET Indium


This modified PET is an excellent example of the This indium standard shows a stable baseline with
types of analysis that can be done in the DSC. The excellent temperature accuracy. Indium has a theoretical
glass transition is analyzed showing onset, midpoint melt onset of 156.6 ℃ with endothermic values of 28.5
and a selected endpoint. Crystallization is the second Joules per gram.
peak with temperature of 127.34 ℃ showing area
analysis as well as temperatures. Finally the melt on
this curve with a peak of 247.47 ℃.
Key Features

 Options
- MCA(Mechanical cooling Accessory)
down to -90 ℃
 DSC Furnace - Liquid nitrogen cooling attachment
 Facilities
- High sensitivity heat flux - Sample Crimper and sealer
- Preheated purge gas
plate
- Blanket purge - Automatic GSA (Gas Switching
- Very low mass furnace
- Multiple types of Accessory) up to 4 gases
- Mineral insulated furnace
sample pans
- Small instrument
footprint

 Powerful Heat Control


- Solid silver block
- Integral cooling jacket
- Multiple sensor plate

designs available 
- Dual PID loops for
Temperature control
- Powerful heating rates

Up to 200 ℃ /min
- Manual or automatic
cooling

Specifications

Temperature : Typically -150 to 725°C Sample and reference thermocouples : Chromel/Alumel (Type K)
Temperature accuracy : 0.1 ℃ Furnace thermocouple : Type K
Temperature Precision : 0.1 ℃ Dual PID control
Sensitivity : <0.5 ㎼ Programmed rate : 0.1 ~200 ℃ /min
Stability : 1 ㎽ ambient to 550 ℃ Typical rate ; 5 to 20 ℃ /min
Heat flux plate material : Chromel or Constantan Dimensions : 535 mm(W) x 370 mm (D) x 250 mm (H)