Safety Precautions
Dear Customers,
Thank you for choosing Haier Combined Refrigerator and Freezer. Before using the equipment, we
advise that you carefully read and understood the contents and signs in this manual. This is to ensure
your safety and prevent potential damage to stored products and the unit.
Safety labels
Symbol for
“Manufacture”
In case of flammable gas leakage such as coal gas, the valve leaking gas should be closed,
open doors and windows for ventilation exhaust, don't plug in or out the power plug of
refrigerator-freezer, or it may cause explosion and fire.
Only professional technicians or after-sale maintenance personnel can install refrigerator-
freezer. Or it may cause electric shock or fire.
Make sure to put the refrigerator-freezer on firm and flat ground surface stably. If the ground is
not firm or not properly placed, refrigerator-freezer may turn over or cause personnel injury.
Please use the special power supply marked on equipment nameplate, or it may cause fire or
electric shock.
If the service voltage is lower than 198V or higher than 264V, automatic voltage regulator of over
640W suitable for motor load should be added.
32 1
If the power wire should be lengthened, the sectional area of extension cord should not be less
than 2mm2, and not be longer than 3m. Or it may cause fire or electric shock.
Power line of refrigerator-freezer has three wire plug (Grounded), and standard three wire
socket (Grounded) meeting 16A. Never cut off or remove the earthing pin of power line.
Make sure the power plug and socket are stuck tightly, firm and reliable, or it may fire.
Please use the power socket connecting ground wire to avoid electric shock.
If the power socket is not grounded, be sure to install the ground wire by professional technician.
Don't use refrigerator-freezer outdoor. When the equipment is drenched by rain, it may cause
electric leakage or electric shock.
Don't place refrigerator-freezer in damp environment or place easy to suffer spray water. Or it
may cause electric leakage or electric shock due to insulation level reduction.
Don't pour water directly on refrigerator-freezer, or it may cause electric shock or short circuit.
Don't put container with water or heavy stuff on refrigerator-freezer. Or the object may fall to
injury person, and the water will reduce insulation level to cause electric leakage or electric
shock.
Refrigerator-freezer should not be grounded through gas pipe, power supply tube, telephone
line or lightning rod. Above earthing may cause electric shock or other danger.
Don't contat any electric parts as power socket and switch with wet hand, or it may cause
electric shock.
When plugging out power socket, hold the power plug firmly and not pull lead of power plug.
Puling lead by hand may cause electric shock or fire due to short circuit.
If the operation of refrigerator-freezer is not normal, please plug out power plug. Continue
operation under abnormal status may case electric shock or fire.
User should not dismantle, repair or modify refrigerator-freezer. Or it may cause fire or personnel
injury due to improper operation.
Make sure to disconnect refrigerator-freezer power before any repair or maintenance of
refrigerator-freezer, or it may cause electric shock or personnel injury.
Be sure not to breath in drug or suspended particle in and around refrigerator-freezer during
repair and maintenance, or it may affect health.
Please use refrigerator-freezer in safe area when storing poisonous, harmful or radioactive
mateials. Improper use may bring harm to human health or environment.
Pull out the power plug if the freezer has been out of service for long time to prevent electric
shock, leakage or fire caused by aging power lines.
If refrigerator-freezer is not used for long time in area without monitoring, please make sure
children will not be close to refrigerator-freezer, and the door should not be closed fully.
The end-of-life disposal of refrigerator-freezer should be done by corresponding person.
Door should be dismantled, or it may cause accident as asphyxia.
Don't light inflammable, explosive hazardous articles or volatile materials in refrigerator-freezer,
nor use flammability spray nearby, or it may cause explosion or fire.
2 31
Packing List Don't store acid, alkali and other corrosives. Or it may damage the internal components or
electrical parts of refrigerator-freezer.
The plastic package bag should not put at easy accessible place for children, or it may ause
Name HYCD-469 HYCD-469A asphyxia accident.
Don't climb on refrigerator-freezer or put objects on it, or refrigerator-freezer may turn over and
Manual 1 1 cause personnel injury or refrigerator-freezer damage.
Defrost shovel 1 1 Don't insert metal objects as iron nail or iron wire into any hole, gap or any exhaust port of
refrigerator-freezer or internal air circulation, or the above objects may contact with moving parts
Plastic bag 1 1 to cause electric shock or injury.
Support 2 2 It needs to examine the setting of refrigerator-freezer when restart it after outage or power off.
The change of setting may damage the stored articles.
Infinite partition board / /
Once the power of refrigerator-freezer is cut off, it needs to wait for 5min before reconnection, or
Shelf label holders 3 3 compressor or system may be damaged.
Shelf 3 3 Please wear gloves for maintenance, or it may cause personnel injury by contacting sharp edge
or corner.
Clips 12 12
Close door by holding handle, or door may clamp finger.
Hasp for padlock 2 2 When moving refrigerator-freezer, the inclination angle should not be bigger than 45°.
Installation Guide for Hasp 1 1 Be careful to move refrigerator-freezer, and not fall over, or it may cause equipment damage or
personnel injury.
Screw(M4*8) 2 2
Don't move equipment by lifting or pulling handle, or it may cause refrigerator-freezer damage
Tapping screw(ST4.2*13) 4 4 or personnel injury.
There should be no obstacles around refrigerator-freezer, keep good ventilation.
Don't damage refrigerating circuit.
Name HYCD-282 HYCD-282A Do not use electrical appliances inside the food storage compartments of the appliance, unless
they are of the type recommended by the manufacturer.
Manual 1 1 The appliance must be positioned so that the plug is accessible.
Defrost shovel 1 1 The appliance must be placed on a solid and flat surface, or excessive vibration and noise may
be produced when the appliance in operation.
Plastic bag 1 1
The appliance can be used by children aged from 8 years and above and persons with reduced
Support 2 2 physical, sensory or mental capacibilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
Infinite partition board 4 4 the hazards involved. Children shall not play with the appliance.
Key 2 2 Cleaning and user maintenance shall not be made by children without supervision.
Hasp for padlock 2 2 If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
Installation Guide for Hasp 1 1
Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of
Screw(M4*8) 2 2 obstruction.
If your cabinet is to be discard, you must remove the door and leave the shelves in place. This
Tapping screw(ST4.2*13) 4 4
will reduce the posibility of danger to children. And the flammable foaming needs to be disposed
by professional persons.
30 3
Keep all ventilation openings in the enclosure or, in the structure for building-in, clear of Name Combined Refrigerator and Freezer
obstruction.
Model HYCD-282 HYCD-282A
Do not use mechanical devices or other means to accelerate the defrosting process, other than
those recommended by the manufacturer. External dimensions
735×660×1810
Do not damage the refrigerant circuit. (WxDxH)(mm)
In order to reduce flammability HAZARDS the installation of this equipment shall only be carried Internal dimensions Refrigeraor: 605x510x720
out by a suitably qualified person. (WxDxH)(mm) Freezer: 515x465x440
Use the fixtures on the rear panel of the unit, and secure the unit to a wall with a strong rope Effective volume Refrigerator: 219L Freezer: 100L
chain or screws. Refrigerator :Glass door
Door Foaming door
When moving the unit, be sure to take precautions to prevent it from falling over. Moving the unit Freezer: Foaming door
with too much force may cause it to fall over, possibly resulting in injury. A qualified individual Insulation material Rigid polyurethane foams (Fluoride-Free)
must be assigned to supervise the safe movement and relocation of the unit.
Compressor Frequency conversion compressor
Shelf/drawer Refrigerator: 3/1 Freezer: 1/2
Max load of each shelf Max:12kg
Refrigerator: Forced air cooling
Cooling type
Freezer: Direct-cooling
Exterior material/Interior
Sprayed steel plate/stainless steel
material
Condenser Bare tube type
Refrigerator: finned type
Evaporator
Freezer: bare tube type
Temperature controller Microprocessor
Refrigerant Refrigerator: R600a 45g / Freezer: R290 60g
Refrigerator lamp LED 1.5W
Net weight 145kg
Temperature range Refrigerator: 2℃ ~8℃ Freezer: -10℃ ~-40℃
Rated power supply 220-240V~ 50/60Hz 220-240V~ 50/60Hz
Rated power/current 410W/2.5A 410W/2.5A
Noise Level 43dB(A) 43dB(A)
Foaming Agent HFO-1233zde HFO-1233zde
Climate Type N N
Electric shock resistance type I
Power connect style Y
High and low temperature, sensor error, power failure, door ajar,
Alarms
high ambient temperature, low battery, romote alarm
Power outage alarm duration 48h (When battery is fully charged)
4 29
Specification Precautions for Use
Name Combined Refrigerator and Freezer • If the refrigerator-freezer is started for first time or not used for a long time, the battery may be low
when testing, this is normal because the rechargeable battery is completely discharged. In such
Model HYCD-469 HYCD-469A situation, switch on battery, and the battery will be fully charged after 6 days of continuous operation
External dimensions of refrigerator-freezer.
738×834×1975
(WxDxH)(mm) •To prevent condensation around freezing chamber cabinet, dew removable tube is installed, when
Internal dimensions Refrigerator: 593×585×800 refrigerator-freezer runs, there may be hot around door frame of freezing chamber cabinet, this is
(WxDxH)(mm) Freezer: 553×545×660 normal.
Effective volume Refrigeraor: 269L Freezer: 200L •Confirm whether the internal temperature is fully reduced before putting things in refrigerator, then
put things in batches when it reaches required temperature, or the temperature may rise.
Refrigerator :Glass door
Door Foaming door •The temperature display value of this product refers to that of heat detector inside, and there is
Freezer: Foaming door
certain deviation for displayed temperature and the actual temperature at center of refrigerator, but it
Insulation material Rigid polyurethane foams (Fluoride-Free) will gradually be close to true temperature.
Compressor Frequency conversion compressor •Two through holes are installed on side wall of this product to bring the measuring line in refrigerator,
Shelf/drawer Refrigerator: 3/0 Freezer: 3/0 and make sure to plug the measuring hole by thermal insulation material after measurement, or the
temperature in refrigerator will not fully reduce.
Max load of each shelf Max:12kg
•Clean equipment by diluted mild detergent (Undiluted detergent may damage plastic compositions,
Refrigerator: Forced air cooling please refer to detergent instruction for dilution method. Don't use brush, acid, and gasoline, soap
Cooling type
Freezer: Direct-cooling powder, polishing powder or hot water to clean refrigerator, or it may damage paint surface and
Exterior material/Interior plastic, rubber parts, and pay extra attention not to use volatile solvent as gasoline to wipe plastic and
Sprayed steel plate / stainless steel rubber parts.
material
Condenser Microchannel
•After running a period of time, the inner wall of refrigerator-freezer will form a layer of frost, too thick
frost will influence refrigeration effect, increase power consumption, so when the frost layer is 5mm at
Refrigerator:finned type certain interval, use attached shovel or “ ” key on control panel to defrost.
Evaporator
Freezer:bare tube type
•Please take things out of refrigerator-freezer before defrosting, and store in another refrigerator-
Temperature controller Microprocessor freezer, or the temperature inside may rise and damage things.
Refrigerant Refrigerator: R600a / Freezer: R290 •There are many cooling coils on inner container, and don't defrost the inner container by knife, ice
Refrigerator lamp LED 0.7W chisel or screwdriver and other sharp edge tool. Pay attention not to scratch evaporation tube, or it
may cause equipment fault.
Net weight 176kg
•For refrigerator-freezer not used for a long time, cut off the power supply, and turn off battery switch.
Temperature range Refrigerator: 2℃ ~8℃ Freezer: -10℃ ~-40℃
Rated power supply 220-240V~ / 50/60Hz 220-240V~ / 50/60Hz
Meaning of crossed –out wheeled dustbin:
Rated power/current 640W/3.0A 640W/3.0A
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Noise Level 45dB(A) 45dB(A)
Contact you local government for information regarding the collection systems available. If electrical
Foaming Agent HFO-1233zde HFO-1233zde appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater
Climate Type N N
and get into the food chain, damaging your health and well-being.When replacing old appliances with
new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of
Electric shock resistance type I charge.
Power connect style Y
High and low temperature, sensor error, power failure, door ajar,
Alarms
high ambient temperature, low battery, romote alarm
Power outage alarm duration 48h (When battery is fully charged)
28 5
Product Feature
This product is mainly used for storage of blood plasma, biological material, vaccine and low Circuit Diagram(HYC-282/282A)
temperature test of video, electronic device and special materials. It is suitable for blood station,
hospital, quarantine station, universities, research institute, electronic chemical and other enterprise
labs.
Note:The content in the frame with dottedlines are applicable for HYCD-319A and HYCD-282A series
1.Temperature control
Computer controlled, digital display of temperature, the normal service range of refrigerating
chamber is 2~8°C, and that of freezing chamber is -10~-40°C.
2.Safety system
•Multiple alarm functions (High and low temperature alarm, power failure alarm, sensor error
alarm, door ajar alarm, high ambient temperature alarm, low battery alarm)
•Visual and audible warning.
•All independent components are safely grounded.
3.Refrigeration system
•Deeply optimized refrigeration system, famous brand compressor and main components have
better refrigeration performance
•Refrigerating chamber and freezing chamber have independent refrigeration control, the
temperature in box is mutual independent
4.User-friendly design
I hereby apologize for the inconformity of your Haier pharmaceutical refrigerator with freezer
with manual figure due to product improvement. Manual content will change without prior
notice.
6 27
Product Installation
Circuit Diagram(HYC-469/469A) Installation environment
•Environment temperature: 16°C to 32°C, the ideal temperature is 18°C to 25°C, and air conditioning
system should be used when necessary.
•Environment humidity: Lower than 85%Rh.
•To avoid a great deal of dust.
•To avoid mechanical swing or vibration.
•The altitude of working position of refrigerator-freezer: Lower than 2,000m.
•Input voltage: no great than ± 10% of rated voltage.
• Overvoltage category: The transient state is Category II facility.
• Pollution Degree:2.
Installation site
To enable the refrigerator-freezer to work normally and obtain best performance, the installation site
of refrigerator-freezer should meet the following conditions:
•It can't be installed in small airtight space, and the door of room for placement should not be smaller
or lower than this product, it should at least allow normal in and out of product, or it may be hard to
repair fault machine, nor timely recover machine and cause stored goods damage.
•Installation ground must be firm and flat.
•Good ventilation, avoid direct sunshine.
•Don't share socket with other equipment plug, plug and socket should be firmly connected.
•Don't bend or press power wire.
•If the power wire should be lengthened, the sectional area of extension cord should not be less than
2mm2, and not be longer than 3m.
•Inspect the working voltage before use, voltage regulator with proper motor load should be
considered in area with unstable voltage. To enable the normal input voltage as 220-240V~ ± 10%,
the power of voltage regulator should be greater than 4000W.
•Refrigerator-freezer must be reliably earthed.
•If power socket has ground wire, check whether it is well earthed before use.
•If the power socket doesn't have ground wire, be sure to install the ground wire by professional
technician.
26 7
Refrigeration Schematic & Circuit Diagram
Warning
•Refrigerator-freezer should not be grounded through gas pipe, water supply tube, Refrigeration schematic diagram (refrigerator)
telephone line or lightning rod, or it may cause electric shock.
The power plug must be accessible after installation, so that it can be unplugged in Refrigeration evaporator
emergency. Nothing can block the ventilation opening of refrigerator-freezer.
Downward upward
Exhaust pipe
Supporting foot
8 25
FAQ
Any questions for use? Doubt the refrigerator-freezer failure? Please look here. 5. Standing
This chapter will give answers to various possible failures, and solutions. After placing and leveling, cleaning machine body, don't power on. Stand for more than 24h before
If the problem is still not solved after operation, please call Haier after-sales power on, and make sure the normal operation of refrigerator-freezer.
service.
Please never repair and dismantle refrigerator-freezer.
24 9
Rechargeable Battery Recycling
•This product is responsible by special person, who will check the operation and record every Install a recyclable charging battery in refrigerator-freezer, and when it is to achieve the service life,
day (Record and check every 2-4h), the temperature in cabinet will rise in case of machine please contact local battery recycle agent for inspection, or correctly discard the battery.
fault or stop, if it can't be repaired in short time, please take out articles and move to the places
meeting storage temperature requirement, and avoid damage. Position of battery
•Before putting goods in this product for storage, confirm in advance that the temperature for
stored goods meets the temperature range of this product, for fear that the temperature of The battery in refrigerator-freezer is for power outage alarm, and it is in electric cabinet.
this product can't reach the required temperature of stored goods and cause goods damage,
resulting in lose. Electric cabinet has high voltage electrical apparatus element.
•The actual display temperature has certain difference with setting temperature due to To prevent electric shock, the cover should be opened by professional engineer or maintenance
refrigeration inertia (The lower the setting temperature of freezing chamber, the smaller the man.
temperature difference, and the greater the versa), this is normal.
Take out the battery
•It is not allowed to put too many things one time, or it may cause compressor non-stop for a
long time, temperature falls slowly and will influence compressor life, goods should be stored in 1. Unplug power plug from socket;
batch, and temperature will fall ladderlike until the required temperature. 2. Remove the screws from electric cabinet cover by screw driver;
•Don't damage refrigerating circuit. 3. Unplug the connection plug of battery;
•Use electrical appliance without the consent of the production in refrigerator-freezer. 4. Dismantle the fixed clamp of battery, and take out battery;
5. Recycle or correctly dispose battery as required.
Operation after Outage When replacing battery, make sure the brown wire is connected to battery anode, blue wire is
connected to battery cathode. Or it is easy to burn the charging circuit of computer board, which
Refrigerator-freezer has memory function for setting value, when it is power on after power failure, will not be able to charge battery.
refrigerator-freezer will continue running with the set parameters before last power failure.
•Once the power of refrigerator-freezer is cut off, it needs to wait for 5min before
Warning
reconnection, or compressor or system may be damaged.
•Please unplug power plug when the refrigerator-freezer is not used for a long time,
and turn the batter switch to “off ”, or it may cause electric shock, electric leakage or
fire due to aging power wire.
•If refrigerator-freezer is not used for long time in area without monitoring, please The brown wire is connected to battery anode
make sure children will not be close to the refrigerator-freezer, and the door should
not be closed fully.
10 23
Component Names·Control Panel
Stop refrigerator-freezer Component Names(HYCD-469)
•If refrigerator-freezer needs to stop working for a long time, you should cut off power and turn the
power switch to “off ”;
•Open refrigerator-freezer door, and take the inner shelf out;
•Completely clear the refrigerator-freezer; Control panel
USB interface
•Clear the shelf;
•When the refrigerator-freezer and shelf are dry, put shelf back into refrigerator-freezer; Door alarm switch
•Close the cabinet door, and put a plastic bag for sealing.
If equipment is not used for long time in area without monitoring, please make sure
Warning
children will not be close to the equipment, and the door should not be closed fully,
the end-of-life disposal of equipment should be done by corresponding person, to
prevent asphyxia accident, make sure to dismantle the cabinet door . Foaming door
Door handle
Door lock
Foot Caster
22 11
Cleaning and Maintenance
Component Names(HYCD-469A) Warning
•To prevent electric shock or personnel injury, make sure to cut off refrigerator-
freezer power before any repair.
•Be sure not to breath in drug or suspended particle around refrigerator-freezer
Light switch during maintenance, or it may affect your health.
Control panel
Cleaning
USB interface
•Refrigerator-freezer should be cleaned once a month. Regular cleaning to make refrigerator-freezer
to keep brand new appearance.
Door alarm switch
•Wipe the dust on refrigerator-freezer shell, inner room and all attachments by dry cloth. If the
refrigerator-freezer is very dirt, clean it by cleaning cloth soaked in neutral detergent, and wipe the
residual detergent by wet cloth, then dry cloth.
•Don't pour water on refrigerator-freezer shell or interior, or it may damage appliance insulation and
cause failure.
Glass door •Compressor and other mechanical parts are in completely seal status without lubrication.
Shelf Inner wall defrosting
The frost is generally close to door seal in cabinet, and frost may result in gap between cabinet and
door seal, causing bad cooling effect, use attached shovel to defrost, the following steps are for
defrosting by moving empty cabinet.
Hasp for padlock •Take out the cabinet articles to other equipment;
•Turn off power switch;
Door handle •Open cabinet door for a period of time to defrost;
•Dry the water at bottom of cabinet by a dry cloth;
•Restart equipment after cleaning cabinet body;
•Put articles back when the cabinet is fully cooled.
If only freezing chamber needs to defrost, you can press defrost key on display board, the operation
Hasp for padlock method is, long press defrost key for 5s after unlocking keyboard, the refrigeration system of freezing
chamber will stop working. After defrosting, manually press defrost key for 5s again to deactivate
defrost mode, the refrigeration system of freezing chamber will restart.
Caution Don't use knife, screw driver and other shape edged tools to defrost.
Battery maintenance
1. For continuous power on of equipment, please inspect battery power every 15 days (See P17 for
inspection method, alarm test function), in case of low battery, make sure the battery switch is turned
on, then the battery will be charged, after continuous charging for a week, please retest battery
power, which should be full in normal condition, if it is still low battery, the charging battery should be
replaced.
2. Power outage alarm battery is consumable, and battery life is about 3 years, if it is used for over 3
Foot Caster years, it may fail to act in case of alarm, battery should be replaced earlier, and please contacts Haier
after-sales servicer.
12 21
Caution
In case of multiple alarms, each alarm failure code will display for 3s respectively. Component Names(HYCD-282)
Battery switch should be opened before normal boot, once the AC power meeting
equipment requirement is connected, equipment will enter into normal work status.
Equipment can charge battery for normal power supply of AC. In case there is
accidental AC power outage, battery will supply power to display screen to enable Door lock Control panel
normal display. When battery discharges with voltage be lower than certain value, it
will stop supplying power, and display screen will stop displaying. When the battery USB interface
supplies power normally, unplug AC power line, turn off equipment battery switch to
Door alarm switch
completely cut off power, and the display screen will not display.
Remote alarm function is limited to three alarm modes, i.e. high temperature alarm, low
Caution
temperature alarm and power failure alarm.
Foot Caster
20 13
Alarm
Component Names(HYCD-282A) After power on, refrigerator-freezer will enter into start status, display screen will show cabinet
temperature.
1.Display panel work status hints:
Light switch
•Lock Indicator: Light on means all settings are locked to prevent misoperation.
•Alarm indicator lamp: Light on or flashing means failure.
Door lock Control panel
2.Key function:
USB interface •Cancel buzzer: In lock or unlock status, press “ ” can clear alarm sound, but not light flashing
Door alarm switch alarm.
•Alarm test: to test that the alarm system is in normal working status, and also low battery. In
unlock status, press “ ”, all indicators are on, with buzzer alarm, all nixie tube shows 8. In
lock status, press this key when there is alarm, and it will show corresponding fault alarm code,
inquiry the following table for fault reasons. If it is sensor fault, no key needs to be pressed, display
interface will directly show fault code.
14 19
U disk data time parameter setting Control Panel
After unlocking, press setting, digit switch, temperature adjustment keys for more than 5s, the first • HYCD-469/282
two digits on refrigerating display screen shows 1P stably, frozen display screen will blinking display
year (10 by default), and the year will increase by 1 for each press of temperature adjustment key,
with circle display from 10 to 30, after setting press setting key to save, then the front two digits on
refrigerating display screen shows 2P stably, frozen display screen will blinking display month (01 by
default).
The month will increase by 1 for each press of temperature adjustment key, with circle display from
01 to 12, after setting press setting key to save, then the front two digits on refrigerating display
screen shows 3P stably, frozen display screen will blinking display date (01 by default); the date will
increase by 1day for each press of temperature adjustment key, with circle display from 01 to 31,
after setting press setting key to save, then the front two digits on refrigerating display screen shows
4P stably, frozen display screen will blinking display month (01 by default);the time will increase by
1h for each press of temperature adjustment key, with circle display from 00 to 23, after setting press • HYCD-469A/282A
setting key to save, then the front two digits on refrigerating display screen shows 5P stably, frozen
display screen will blinking display month (01 by default); the time will increase by 1min for each
press of temperature adjustment key, with circle display from 00 to 59, after setting press setting key
to save, and it will automatically exit if there is no key operation for 10s after setting.
•When export data to USB disk, please use an USB disk with a file format of FAT32.
Caution
•If the FAT32 USB disk cannot export data, please backup the file of the USB disk first
and then format the USB disk or try another brand FAT32 USB disk.
18 15
Application method
Temperature setting Caution
•The default temperature setpoint of refrigerator chamber is 5°C and , the freezer
chamber is -40°C;
1. Unlock •For non-use setting, the default value is 1, meaning the normal operation of current
When the lock indicator lights, all keys are locked except digits switch key, it should be unlocked activated area, 0 means the current activated area is disabled; (Only in the parameter
before setting parameters, the unlock steps are as follows: of L5, if you want to change the value, you will need to press "temperature adjustment"
for 5 seconds; the value could only be increased by "1" for each long press)
•Long press digits switch key for more than 5s, the display area shows F0, 0 digit flashing;
•Voltage and environment temperature can only be inquired, but can't be set .
•Press temperature adjusting key, display area shows F1;
•High-low temperature alarm value can be set within the following range:
•Press setting key, lock indicator goes out, and the keyboard is unlocked.
The highest setting temperature+5°C≥high temperature alarm value≥setting
2. User parameter setting temperature+5°C
User can change the setting temperature, alarm value, start delay and other parameters of The lowest setting temperature-5°C≤low temperature alarm value≤setting
refrigerating chamber or freezing chamber through control panel. These settings are independent for temperature-5°C
refrigerating chamber and freezing chamber. The operations as refrigerating chamber setting will be •The “├” in front of figure represents “+”.
shown on the display screen of refrigerating chamber on left side of display panel, and the parameter
adjustment of freezing chamber will be shown on the refrigerating chamber on right side of display • Start delay setting
panel. The activated setting area will make blinking display, to activate another setting area, you can
press temperature switch key. a.In unlock status, press setting key and temperature adjustment key for 5s, the display screen
activated by default will show the delay time of current area compressor, then the temperature area
• Parameter inquiry and setting can be changed by temperature area switch;
a. Press setting key under unlock status, the display screen activated by default will show L0, 0 b.Press temperature adjustment key to change start delay time;
digit flashing, then the temperature area can be changed by temperature area switch;
c.Press setting key when adjusting to required value, change and save parameters.
b. Press temperature adjustment key to adjust L0 to L1, L2, L3, L4, L5;
•Freezing chamber defrost
c. Adjust to designated parameter, and press setting value, the display screen will show the setting
value of that area, and the value at units' digit will flash, the corresponding list of parameter code is In unlock status, press freezing defrost for more than 5s, the refrigeration system of freezing
as follows: chamber will stop running, the display screen of cold storage area will show dF, it can't make auto
reply in this status, but long press freezing defrost key under unlock status again for more than 5s
Parameter Parameter to exit defrost mode, dF will disappear from display screen of cold storage area after successful
Parameter meaning Parameter meaning
code code exit.
L0 Temperature setpoint L3 Current voltage inquiry • In all parameter adjustment, if there is no operation within 10s, system will save
Caution
Current ambient temperature current setting and exit parameter setting mode;
L1 High temperature alarm setpoint L4 • For parameter adjustment, frozen area setting is activated by default for first use, if it
inquiry
needs to switch to cold storage area setting, press temperature switch key. If it is not
L2 Low temperature alarm setpoint L5 Non-use setting for first use, the final set temperature area is activated by default;
d.Press digit switch key to change the flashing digit, press temperature adjustment key to change
current digit value; U disk data reading method
e.Press setting key when adjusting to required temperature, change and save parameters.
U disk interface is on the right of refrigerator-freezer top display board. After inserting U disk to
interface, cabinet will automatically identify and import temperature data. Meanwhile press setting
and temperature area switch key on display board for 5s, check whether data is imported to U disk. If
not, display screen will show "USB" "……"; or it will show "USB""OK". Unplug U disk after importing,
and open the data in computer by text or excel. This product can save the cabinet temperature data
in recent 10 years, if it is more than 10 years, the previous data will be replaced automatically.
16 17