ZK2-E
ZK2-E
ZK2-E
ZK2-OM00501-B
PRODUCT NAME
ZK2-ZSV####-A
Table of Contents
A
Safety Instructions 2
Model indication and How to order 9
Summary of Product parts 10
Definition and terminology 11
Wiring 15
Wiring 15
Internal circuit and wiring example 16
Mounting and Installation 17
Installation 17
Easy Setting 18
Measurement mode 18
Function Setting 22
Function selection mode 22
Default setting 22
F0 Unit selection function 24
F1 OUT1 25
F2 OUT2 27
F3 Response time 29
F4 Auto-preset 30
F6 Fine adjustment of display value 32
F11 Display resolution 33
F80 Power saving mode 34
F81 Security code 35
F90 Setting of all functions 36
F96 Check of suction command signal 38
F98 Check of output 39
F99 Reset to the default setting 41
Other Settings 42
How to stop energy-saving control function 45 B
Maintenance 46
Troubleshooting 47
Error indication 54
Specification 55
-1-
NO.ZK2-OM00501-B
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or
"Danger". They are all important notes for safety and must be followed in addition to International
standards (ISO/IEC) 1) and other safety regulations.
1) ISO 4414: Pneumatic fluid power -- General rules relating to systems
ISO 4413: Hydraulic fluid power -- General rules relating to systems
IEC 60204-1: Safety of machinery -- Electrical equipment of machines (Part 1: General requirements)
ISO 10218-1992: Manipulating industrial robots -Safety.
etc.
CAUTION indicates a hazard with a low level of risk which, if not avoided,
Caution : could result in minor or moderate injury.
WARNING indicates a hazard with a medium level of risk which, if not
Warning : avoided, could result in death or serious injury.
DANGER indicates a hazard with a high level of risk which, if not avoided,
Danger : will result in death or serious injury.
Warning
1. The compatibility of the product is the responsibility of the person who designs the
equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with
specific equipment must be decided by the person who designs the equipment or decides its
specifications based on necessary analysis and test results. The expected performance and safety
assurance of the equipment will be the responsibility of the person who has determined its
compatibility with the product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due consideration to any
possibility of equipment failure when configuring the equipment.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and
maintenance of machines or equipment including our products must be performed by an operator
who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be performed after measures
to prevent falling or runaway of the driven objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned above are
implemented and the power from any appropriate source is cut, and read and understand the
specific product precautions of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and
malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is
to be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed
to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,
vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or
other applications unsuitable for the standard specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special
safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by
using a mechanical protective function, and periodical checks to confirm proper operation.
-2-
NO.ZK2-OM00501-B
Caution
The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange
specifications or a contract if necessary.
If anything is unclear, contact your nearest sales branch.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of weapons of mass
destruction (WMD) or any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are governed by the
relevant security laws and regulation of the countries involved in the transaction. Prior to the
shipment of a SMC product to another country, assure that all local rules governing that export are
known and followed.
-3-
NO.ZK2-OM00501-B
Operator
This operation manual is intended for those who have knowledge of machinery using pneumatic
equipment, and have sufficient knowledge of assembly, operation and maintenance of such
equipment. Only those persons are allowed to perform assembly, operation and maintenance.
Read and understand this operation manual carefully before assembling, operating or providing
maintenance to the product.
■Safety Instructions
Warning
■Do not disassemble, modify (including changing the printed circuit board) or repair.
An injury or failure can result.
■Do not use the product except for energy-saving control ejector
Fire, malfunction, or damage to the product or the system can result.
■Do not use the product in a place where static electricity is a problem.
Otherwise it can cause failure or malfunction of the system.
■Verify the system sufficiently before judging the applicability when a permeable workpiece is to be sucked.
Rapid decrease in vacuum pressure during suction of the workpiece may cause the ejector to fail to restart
in time, causing injury or damage to the system because of the suction failure.
-4-
NO.ZK2-OM00501-B
Caution
■Do not touch the terminals and connectors while the power is on.
Otherwise electric shock, malfunction or damage to the product can result.
■NOTE
○ Follow the instructions given below when designing, selecting and handling the product.
●The instructions on design and selection (installation, wiring, environment, adjustment,
operation, maintenance, etc.) described below must also be followed.
Product specifications
Use the specified voltage.
Otherwise failure or malfunction can result.
Do not exceed the specified maximum allowable load.
Otherwise it can cause damage or shorten the lifetime of the Pressure switch.
Design the product to prevent reverse current when the circuit is opened or the product is forced to operate for
operational check.
Reverse current can cause malfunction or damage to the product.
Input data to the Pressure switch is not deleted, even if the power supply is cut off.
(Writing time: 1,000,000 times)
For the details of compressed air quality, refer to ISO 8573-1, 1.1.2 to 1.6.2: 2001.
This can cause operating failure.
If compressed air containing condensate is used, install an air dryer or drain catch before the filter and perform
drainage regularly.
If drainage is not performed regularly and condensate enters the secondary side, it can cause operating failure of
pneumatic equipment.
If regular drainage is difficult, the use of a filter with an auto drain is recommended.
Applicable fluid is air, inert gases and incombustible gases.
Do not use a fluid containing chemicals, synthetic oils including organic solvent, salt and corrosive gases.
Otherwise, damage to the product and malfunction can result.
Check the details of the specifications before using.
Use the specified measurement flow rate and operating pressure.
Otherwise it can cause damage to the pressure switch or inability to measure correctly.
Reserve a space for maintenance.
Allow sufficient space for maintenance when designing the system.
-5-
NO.ZK2-OM00501-B
●Product handling
Installation
Tighten to the specified tightening torque.
If the tightening torque is exceeded the mounting screws and brackets may be broken.
If the tightening torque is insufficient, the product can be displaced and loosen the mounting screws.
(Refer to page 17)
Be sure to ground terminal FG when using a commercially available switch-mode power supply.
Do not drop, hit or apply excessive shock (over 100 m/s2) to the Pressure switch.
Otherwise damage to the internal parts can result, causing malfunction.
Do not pull the lead wire forcefully, not lift the product by pulling the lead wire. (Tensile force 20 N or
less)
Hold the body when handling to avoid the damage of the Pressure switch which lead to cause the failure and
malfunction.
Eliminate any dust left in the piping by air blow before connecting the piping to the product.
Otherwise it can cause damage or malfunction.
Do not insert metal wires or other foreign matter into the pressure measurement port.
It can damage the pressure sensor causing failure or malfunction.
Never mount a Pressure switch in a location that will be used as a foothold.
The product may be damaged if excessive force is applied by stepping or climbing onto it.
If the entering of foreign material to the fluid is possible, install and pipe the filter or the mist separator to
the inlet to avoid failure and malfunction.
-6-
NO.ZK2-OM00501-B
Wiring
Do not pull the lead wires.
In particular, never lift a Pressure switch equipped with fitting and piping by holding the lead wires.
Otherwise damage to the internal parts can result, causing malfunction or to be off the connector.
Avoid repeatedly bending or stretching the lead wire, or placing heavy load on them.
Repetitive bending stress or tensile stress can cause the sheath of the wire to peel off, or breakage of the wire.
If the lead wire can move, fix it near the body of the product.
The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the
outside diameter of the insulation material, whichever is larger.
Replace the damaged lead wire with a new one.
Wire correctly.
Incorrect wiring can break the Pressure switch.
Do not perform wiring while the power is on.
Otherwise damage to the internal parts can result, causing malfunction.
Do not route wires and cables together with power or high voltage cables.
Otherwise the product can malfunction due to interference of noise and surge voltage from power and high voltage
cables to the signal line. Route the wires (piping) of the product separately from power or high voltage cables.
Confirm proper insulation of wiring.
Poor insulation (interference from another circuit, poor insulation between terminals, etc.) can lead to excess
voltage or current being applied to the product, causing damage.
Design the system to prevent reverse current when the product is forced to operate for operational
check.
Depending on the circuit used, insulation may not be maintained when operation is forced, allowing reverse current
to flow, which can cause malfunction and damage the product.
Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage.
Do not use a cable longer than 10 m.
Wire the DC(-) line(blue) as close as possible to the power supply.
Environment
Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam.
Otherwise failure or malfunction can result.
Do not use in a place where the product could be splashed by oil or chemicals.
If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent,
even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires).
Do not use in an area where surges are generated.
If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction
furnace, motor, etc.) close to the Pressure switch, this may cause deterioration or breakage of the internal circuit of
the Pressure switch. Avoid sources of surge generation and crossed lines.
Do not use a load which generates surge voltage.
When a surge-generating load such as a relay or solenoid is driven directly, use a Pressure switch with a built-in
surge absorbing element.
The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes
in the system.
This product is CE marked, it may happen that the set value of product is changed by the noise impressed in
excess.
Mount the product in a place that is not exposed to vibration or impact.
Otherwise failure or malfunction can result.
-7-
NO.ZK2-OM00501-B
Prevent foreign matter such as remnant of wires from entering the Pressure switch.
Take proper measures for the remnant not to enter the Pressure switch in order to prevent failure or malfunction.
Do not use the product in an environment that is exposed to temperature cycle.
Heat cycles other than ordinary changes in temperature can adversely affect the inside of the product.
Do not expose the product to direct sunlight.
If using in a location directly exposed to sunlight, shade the product from the sunlight.
Otherwise failure or malfunction can result.
Keep within the specified fluid and ambient temperatures range.
The fluid and ambient temperatures should be 5 to 50 oC. Operation under low temperature leads to cause damage
or operation failure due to frozen moist in the fluid or air.
Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water.
Avoid sudden temperature change even within specified temperature.
Do not operate close to a heat source, or in a location exposed to radiant heat.
Otherwise malfunction can result.
Maintenance
Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of
air before performing maintenance.
There is a risk of unexpected malfunction.
Perform regular maintenance and inspections.
There is a risk of unexpected malfunction.
Perform drainage regularly.
If condensate enters the secondary side, it can cause operating failure of pneumatic equipment.
Do not use solvents such as benzene, thinner etc. to clean the Pressure switch.
They could damage the surface of the body and erase the markings on the body.
Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully
squeezed, then wipe up the stains again with a dry cloth.
-8-
NO.ZK2-OM00501-B
Model Indication and How to order
How to order
-9-
NO.ZK2-OM00501-B
Summary of Product parts
Output (OUT1) LED (green): LED is ON when the switch output (OUT1) is ON.
Output (OUT2) LED (Red): LED is ON when the supply pilot valve is ON.
LED display: Displays the current status of pressure, setting mode and error code.
button (UP): Selects a mode and increases ON/OFF set value.
Press this button to change to the peak display mode.
button (DOWN): Selects a mode and decreases ON/OFF set value.
Press this button to change to the bottom display mode.
button (SET): Press this button to change to another mode and to set a value.
-10-
NO.ZK2-OM00501-B
■Definition and terminology A
No. Terms Meaning
7 Display type where each individual display character consists of up to 7 separate
7-segment indication sections (called segments)
(The figure “8” uses all 7 segments)
A Indicate the command signal which generate vacuum.
Adsorption directive signal
(It is necessary to input the pressure switch)
An indicated pressure value can be adjusted within the range of ±5% R.D.
Fine adjustment of display (±5% of the indicated value). It is used if a true pressure value is known or to
value correct the difference of an indicated value of the measurement equipment
nearby that measures the same pressure as the Pressure switch.
Abbreviation for full span and full scale; means the maximum fluctuation range
F.S. (full span/full scale)
of the Pressure switch rated value.
H Hysteresis Difference between the points at which the Pressure switch is turned on and off.
Hysteresis mode Refer to "List of output modes" on page 25
-11-
NO.ZK2-OM00501-B
A
No. Terms Meaning
I Indication accuracy Shows the deviation between displayed pressure value and the true pressure.
Insulation resistance of the product.
Insulation resistance
The resistance between the electrical circuit and the case.
How fine the rated pressure range can be segmented. (Example: If a product
Indication resolution for 0 to 1 MPa can indicate pressure by 0.001 MPa, the indication resolution is
1/1000.)
Indication LED The LED that turns on when the switch output is ON.
Indication unit The unit of pressure used in the display.
K Function that prevents changes to the settings of the Pressure switch (disables
Key lock function
button operation).
M Manual pressure setup without using auto preset.
Manual set up This term is used to distinguish between manual and auto preset pressure
setup.
The maximum value of applied voltage available to the output line of the NPN
Max. applied voltage
output.
The maximum (minimum) load (resistance value and impedance) which can be
Max. (Min) load impedance
connected to the output (output line) of the analog current output.
The condition in which the pressure is being detected and indicated and switch
Measurement mode
operation is enabled.
Min. setting unit Refer to "digit".
N One of the switch output types. In hysteresis mode the switch output is turned
ON when pressure equal to or greater than the switch output set value is
Normal output
detected.
Refer to "List of output modes" on page 25)
NPN (open collector) (output) The switch that uses the NPN transistor for output.
O The operation principle of the switch output.
Output configuration
Refer to "List of output modes" on page 25 for the operation status.
Output mode Either hysteresis mode can be selected.
-12-
NO.ZK2-OM00501-B
No. Terms Meaning
P Peak value display Displays the maximum vacuum pressure reached up to that moment.
The solenoid valve which turns on and off the ejector.
Pilot valve for air supply
(This pressure switch outputs signal to the supply pilot valve)
PNP (open collector) (output) The switch that uses the PNP transistor for output.
The condition in which the indicated value turns off and current consumption is
Power saving mode
reduced.
The setting of pressure to determine the point at which the Pressure switch
Pressure setting
turns on and off.
Pressure limit that if exceeded will result in mechanical and/or electrical damage
Proof pressure
to the product.
R The pressure range in which the Pressure switch satisfies the specifications.
Rated pressure range Values over this range can be set if they are within the set pressure range, but
cannot assured the specifications to be satisfied.
-13-
NO.ZK2-OM00501-B
A
No. Terms Meaning
S Setting of function Refer to "Function selection mode".
Setting pressure range. The pressure range within which switch output can be set.
Output type that only has 2 possible states, ON or OFF. Sometimes referred to
Switch output
as "ON-OFF output".
U Function to change the unit in which the value of pressure is indicated. Only a
product with this function can change the unit. A product with unit-changing
Unit selection function
function cannot be purchased if it is used within Japan. Pressure is indicated
only by SI units in Japan.
W A measure of the product’s resistance to a voltage applied between the
electrical circuit and case.
Withstand voltage
The product may be damaged if a voltage over this value is applied.
(The withstand voltage is not the supply voltage used to power the product.)
Z Zero clear (function) Adjusts the displayed pressure value to "0".
-14-
NO.ZK2-OM00501-B
Wiring
■Wiring
○Connection
Connections should only be made with the power supply turned off.
Use separate routes for the Pressure switch wiring and any power or high voltage wiring. Otherwise,
malfunction may result due to noise.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode
power supply. When a switch-mode power supply is connected to the product, switching noise will be
superimposed and the product specification can no longer be met. This can be prevented by inserting a
noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the
product, or by using a series power supply instead of a switch-mode power supply.
Connecting/Disconnecting
When mounting the connector, insert it straight into the socket holding the lever and connector body, and
push the connector until the lever hooks into the housing, and locks.
When removing the connector, press down the lever to release the hook from housing and pull the
connector straight out.
Pin No. of the Connector (Power supply and output cable for the digital pressure switch and pilot
valve)
-15-
NO.ZK2-OM00501-B
■Internal circuit and wiring example
NPN output type
NPN open collector 2 outputs, Max. applied voltage 26.4VDC, Max. load current 80mA
Residual voltage 2 V or less
-16-
NO.ZK2-OM00501-B
Mounting and Installation
■Installation
Mount the O-ring provided into the O-ring groove of the pressure switch, and mount the pressure switch to
the ejector body with the two mounting screws provided. (The required tightening torque is 0.08 to 0.10 Nm)
If the tightening torque is exceeded, the mounting part can be deformed and broken.
-17-
NO.ZK2-OM00501-B
Easy Setting
■Measurement mode
The measurement mode is the condition where the pressure is detected and indicated, and the switch
function is operating.
This is the basic mode, and other modes should be selected for setting changes and other function settings.
-18-
NO.ZK2-OM00501-B
See below for the energy saving control operation and the set values which are preset to the switch.
If the operation shown below is acceptable, then keep these settings.
Function that enables the easy setting of the ON and OFF points of the switch output, and the operation of the
supply pilot valve.
Operation of OUT1
When the pressure exceeds the set value (P_1), the pressure switch will be turned ON.
When the pressure falls below the set value (P_1) by the amount of hysteresis value (H_1), the switch will be
turned OFF.
The default settings are P_1: -70.0 kPa and H_1:10.0 kPa.
Operation of OUT2
Supply pilot valve: OUT2 is turned on by the signal for suction. Suction starts by the generation of vacuum
pressure.
When the vacuum pressure reaches the set value (P_1), the supply pilot valve turns OFF.
After the supply pilot valve is turned off, the vacuum pressure will decrease, when the vacuum pressure drops
below (P_1) by the amount set in (P_2) the supply pilot valve will turn on again and increase the vacuum
pressure.
After that, supply pilot valve will turn ON and OFF repeatability.
Default setting is H_2: 5.0 kPa.
-19-
NO.ZK2-OM00501-B
<How to change the set value>
A
「Normal output (OUT1)」
(1) Press the button once in measurement mode. (Refer to page 18)
Press the button once to increase by one digit, and press it continuously to keep increasing the set
value.
Press the button once to decrease by one digit, press it continuously to keep decreasing the set
value.
(4) Press the button to complete the setting of “P_1”. The display shows [H_1] and the set value in turn.
The button is to increase and the button is to decrease the set value.
(5) Press the button to complete the setting of “H_1”. The display shows [H_2] and the set value in
turn.
The button is to increase and the button is to decrease the set value.
When the reversed output is changed, the following parameters are displayed, and each set value can be
changed, using the method shown above.
For details of how to change the reversed output, refer to the setting of each function.
-20-
NO.ZK2-OM00501-B
「Reversed output (out1)」 A
-21-
NO.ZK2-OM00501-B
Function Setting
■Function selection mode
In measurement mode, press the button for 2 seconds or longer to display [F 0]. Select to display the
function setting to be changed, [F ].
Press the button for 2 seconds or longer in function selection mode to return to measurement mode.
■Default setting
The default settings are as follows
-22-
NO.ZK2-OM00501-B
A
Item Page Default setting
[F 3] Response time See page 29 2.5 ms
[F 4] Auto-preset See page 30 Manual
[F 6] Fine adjustment of display value See page 32 0%
[F11] Display resolution See page 33 1000-split
[F80] Power saving mode See page 34 OFF
[F81] Security code See page 35 OFF
[F90] Setting of all functions See page 36 OFF
[F96] Check of suction command condition See page 38 OFF
[F98] Check of output See page 39 Normal
[F99] Reset to the default setting See page 41 OFF
-23-
NO.ZK2-OM00501-B
■[F 0] Unit selection function
Setting is only possible when using a product with the unit selection function.
(kPa/MPa can still be selected if the product does not have the unit selection function.)
<Operation>
Press the or button in function selection mode to display [F 0].
-24-
NO.ZK2-OM00501-B
■[F 1] Setting of OUT1
The output mode of OUT1 can be set.
Reversed output, pressure value and hysteresis can be set.
-25-
NO.ZK2-OM00501-B
<Operation>
Press the or button in function selection mode to display [F 1].
Setting of pressure
Press the or button to
adjust pressure setting.
Setting of hysteresis
Press the or button to
select hysteresis.
-26-
NO.ZK2-OM00501-B
■[F 2] Setting of OUT2
Set OUT2.
Set ON and OFF points of the supply pilot valve, and the range in which an input is not allowed. A
Operation of OUT2
Supply pilot valve: OUT2 is turned on by the signal for suction. Suction starts by the generation of vacuum
pressure.
When the vacuum pressure reaches the set value (P_1 ‐ H_3: OFF point of supply pilot valve signal),
the supply pilot valve is turned off.
After that, when the vacuum level decreases and reaches the suction switch ON point (P_1 + H_2: Supply
pilot valve signal ON point), the supply pilot turns on again to maintain the vacuum.
After the supply pilot valve is turned off, the vacuum pressure will decrease.
When the vacuum pressure reaches the suction switch ON point (P_1 + H_2: ON point of supply pilot
valve signal), the solenoid valve for supply will turn ON again and increase the vacuum pressure.
Afterwards, The supply pilot valve repeats this ON and OFF cycle.
Area in which setting of H_2 is prohibited can be set by the range in which H_4: supply pilot valve signal is
prohibited to input.
The default settings are P_1:-70.0 kPa, H_1:10.0 kPa, H_2:5.0 kPa, H_3:0.0 kPa, H_4:1.0 kPa
-27-
NO.ZK2-OM00501-B
<Operation>
A
Press the or button in function selection mode to display [F 2].
-28-
NO.ZK2-OM00501-B
■[F 3] Response time
Select the response time of the switch output.
Output chattering can be prevented by setting the response time.
<Operation>
Press the or button in function selection mode to display [F 3].
-29-
NO.ZK2-OM00501-B
■[F 4] Auto-preset function
This function calculates and sets the pressure values automatically based on the on-going operation.
<Operation>
Press the or button in function selection mode to display [F 4].
Setting of auto-preset
Press the or button to select auto-preset.
: ON/OFF point of the supply pilot valve and the set point of the input prohibited range of the supply pilot valve may be corrected
by the auto-preset function.
-30-
NO.ZK2-OM00501-B
Auto-preset
When auto-preset is selected in function selection mode, the set value can be calculated and memorized
from the measured pressure. Repeating the suction and release of a workpiece several times automatically
optimizes the set value.
4, Completion of setting
Press the button to set [P_1] and [H_1] (in reverse output mode [n_1] and [H_1] are set) and complete
auto-preset mode. The pressure switch will then return to measurement mode.
([n_1] and [H_1] are set in reverse output mode.)
To clear the stored auto-preset settings, press the and buttons simultaneously for 1 second or
longer.
-31-
NO.ZK2-OM00501-B
■[F 6] Fine adjustment of display value
This function is used to manually perform fine adjustment of the displayed pressure.
It is adjustable within the range ±5% R.D.
<Operation>
Press the or button in function selection mode to display [F 6].
-32-
NO.ZK2-OM00501-B
■[F11] Display resolution
This function is used to change the pressure display resolution.
This can be used to prevent the digits from flickering on the display.
<Operation>
Press the or button in function selection mode to display [F11].
: It may not be possible to change the resolution depending on the unit of pressure selected..
The units that allow display resolution to be selected are MPa, kPa, kgf/cm 2, psi and inHg.
(The units kgf/cm2, bar, psi and inHg can only be set when using a product with unit conversion function.)
[F 0] Unit selection function on page 24.
-33-
NO.ZK2-OM00501-B
■[F80] Power saving mode
Power saving mode is selectable.
When selected and no buttons are pressed for 30 seconds, the pressure switch will shift to power saving
mode.
The default setting is normal mode (power saving mode off).
<Operation>
Press the or button in function selection mode to display [F80].
In power saving mode 2, when buttons are pressed the display is normal, but if no buttons are pressed for
30 seconds, it will revert to power saving mode. (Power saving is only enabled in measurement mode).
In power saving mode 2, a decimal point flashes and moves across the display.
(In saving mode 2, a decimal point flashes and modes across the display.)
-34-
NO.ZK2-OM00501-B
■[F81] Security code
A security code can be selected, which must be entered to unlock the keys when the keys are locked.
In the default setting, entry of a security code number is not required.
<Operation>
Press the or button in function selection mode to display [F81].
If the security code is used, it becomes necessary to enter the security code to release the key lock.
The security code number can be set to a different value by an operator.
The default setting is "000".
-35-
NO.ZK2-OM00501-B
■[F90] Setting of all functions
All functions can be set, one after the other.
<Operation>
Press the or button in function selection mode to display [F90].
-36-
NO.ZK2-OM00501-B
Order of function of setting
Order Function
1 Selection of display unit
2 Setting of output mode (OUT1)
3 Setting of reversed output (OUT1)
4 Setting of pressure (OUT1)
5 Setting of hysteresis (OUT1)
6 Setting of output mode (OUT2)
7 Supply pilot valve signal ON point
8 Supply pilot valve signal OFF point
Setting of hysteresis (OUT2)
9
Set the range in which the supply pilot valve input is prohibited
10 Setting of response time
11 Setting of display resolution
12 Setting of auto-preset
13 Setting of initialization of fine adjustment of display value
14 Setting of power saving mode
15 Setting of security code
: Return to measurement mode from any setting item by pressing the S button for 2 seconds or longer.
-37-
NO.ZK2-OM00501-B
■[F96] Check of suction command signal
<Operation>
Press the or button in function selection mode to display [F96].
-38-
NO.ZK2-OM00501-B
■[F98] Check of output
Output from the switch can be confirmed.
The output can be turned ON/OFF manually.
<Operation>
Press the or button in function selection mode to display [F98].
Output check
Press the or button to select output check.
Return to
function
selection mode.
-39-
NO.ZK2-OM00501-B
OUT2 check of output
Press the or
button to select check of
output2.
Press the
After returning to [n](normal output),
button for 2
press the button to complete the
seconds or
output check.
longer.
Return to measurement mode from any point by pressing the button for 2 seconds or longer.
-40-
NO.ZK2-OM00501-B
■[F99] Reset to the default setting
If the setting of the pressure switch becomes unknown, the default setting can be restored.
<Operation>
Press the or button in function selection mode to display [F 99].
-41-
NO.ZK2-OM00501-B
Other Settings
○Peak/Bottom hold value display
The maximum (minimum) vacuum pressure from when the power was supplied to this moment is detected
and updated.
For peak display, when the button is pressed for 1 second or longer, the maximum vacuum pressure and
"Hi" starts flashing, and is held.
To release the display of the peak pressure value, press the button for 1 second or longer.
For bottom display, when the button is pressed for 1 second or longer, the minimum vacuum pressure
and "Lo" starts flashing and is held.
To release the display of the bottom pressure value, press the button for 1 second or longer again to
return to measurement mode.
If the and buttons are pressed simultaneously for 1 second or longer while the vacuum pressure is
being held, the maximum (minimum) values are reset.
○Zero clear
The displayed value can be adjusted to zero when the pressure to be measured is within +/-3.5%F.S. of the
zero point set at the time of shipment from the factory.
Perform zero-clear while pressure is not applied.
The zero clear range varies by ±1%F.S. due to variation between individual products.
When the and buttons are pressed for 1 second or longer simultaneously, display is reset to zero.
Measurement mode is returned to automatically.
○Key-lock function
The key lock function is used to prevent errors occurring due to unintentional changes of the set values.
If a button operation is performed while the key lock setting is ON, "LoC" is displayed for approximately 1
second.
(When the button is pressed, the set pressure will be displayed following "LoC".)
(2) Press either the or button to select between locking and unlocking the keys.
-42-
NO.ZK2-OM00501-B
<Operation -With security code->
Locking
1, Press and hold the button for 5 seconds or longer in measurement mode.
[UnL] is displayed.
Unlocking
1, Press and hold the button for 5 seconds or longer in measurement mode.
[LoC] is displayed.
3, When the button is pressed, input of the security code will be requested.
For how to enter the security code, refer to "How to entry the security code" on page 44.
4, If the security code entered is correct, the display changes to [UnL], and pressing any of the , or
buttons releases the key lock and returns the device to measurement mode.
If the security code entered is incorrect, [FAL] is displayed, following which the security code input
screen returns.
If the wrong security code is entered 3 times, [LoC] is displayed and the device returns to measurement
mode.
-43-
NO.ZK2-OM00501-B
How to change the security code
At the time of shipment, the security code is set to [000], but this can be changed to any number.
<Operation>
1, After the key lock setting has been completed, perform all three steps in the unlock setting
procedure. (page 43, "3,").
2, After the security code is entered and the indication changes to [UnL], Press and hold the and
buttons simultaneously for 5 seconds or longer.
[000] is displayed and the new security code should be entered.
For how to input the security code, refer to "How to input and change the security code".
The new security code will be displayed.
3, Check the new security code is as desired and press the button for 1 second or longer.
Return to the measurement mode.
At this time, if the or button is pressed, the security code is not changed and a new security
code should be entered.
-44-
NO.ZK2-OM00501-B
How to stop energy-saving control function B
If a large amount of leakage is generated at the work piece adsorption surface, energy-saving control
frequently occurs (the valve is turned ON and OFF when the vacuum is generated / stopped). In order to
avoid this phenomenon, update the switch setting to stop the energy-saving control as shown below.
Normal energy-
saving control
For stopping the energy-saving function, change the setting of H_3 to P_1 – H_3 ≦ –100.
Refer to page 25[F 2]OUT2 setting for the setting of H_3.
-45-
NO.ZK2-OM00501-B
Maintenance
How to reset the product for power cut or forcible de-energizing
The setting of the product will be retained as it was before a power cut or de-energizing.
The output condition is also basically recovered to that before a power cut or de-energizing, but may change
depending on the operating environment. Therefore, check the safety of the whole facility before operating the
product.
If the facility is under accurate control, wait until it has warmed up. (Approximately 10 to 15 minutes)
-46-
NO.ZK2-OM00501-B
Troubleshooting
Troubleshooting
Applicable Pressure switch: ZK2-ZSV-A
If an operational failure of the pressure switch occurs, please select the cause of failure from the flow chart
below.
If a cause applicable to the failure cannot be identified and normal operation can be recovered by
replacement with a new pressure switch, this indicates that the pressure switch itself was faulty.
The damage to the pressure switch may have been caused by the operating environment (network
construction, etc.). Consult with SMC separately to obtain countermeasures.
The pressure
The switch output The indication Refer to error
switch does not
is ON LED is ON No.1
operate correctly
Yes
Refer to error
No No.2
Refer to error
No.3
-47-
NO.ZK2-OM00501-B
A
Pressure display
difference when using Refer to
2 or more Pressure reference No.10
switches
Refer to
reference No.15
-48-
NO.ZK2-OM00501-B
Cross-reference for troubleshooting
Error
Problem Possible cause Investigation method Countermeasure
No.
Output remains
ON. (1) Check the set pressure value.
(1) Reset the pressure
Indication LED (2) Check the settings of the
Incorrect pressure settings.
remains ON. hysteresis and output type.
1 setting (2) Reset the function
Output remains (Normal output/reversed
settings.
OFF. output(out1) )
Indication LED
remains OFF. Product failure Replace the product.
-49-
NO.ZK2-OM00501-B
Error
Problem Possible cause Investigation method Countermeasure
No.
Pressure is not
Return the applied pressure
atmospheric Check that a pressure above
to atmospheric pressure,
pressure at ±3.5%F.S. was not applied, during
and retry the zero clear
zero-clear zero-clear operation.
operation.
operation (Er3).
-50-
NO.ZK2-OM00501-B
Error
Problem Possible cause Investigation method Countermeasure
No.
Incorrect power Check if the power supply voltage is in Supply power supply
supply the range 24 VDC ±10%. voltage of 24 VDC ±10%.
Incorrect power Check if the power supply voltage is in Supply power supply
supply the range 24 VDC ±10%. voltage of 24 VDC ±10%.
-51-
NO.ZK2-OM00501-B
Error
Problem Possible cause Investigation method Countermeasure
No.
Install a 5 m filter to
prevent foreign matter from
getting into the pressure
Check if any foreign matter has
Foreign matter port.
entered the pressure port.
Also, clean the filter
regularly to prevent
drainage deposits.
-52-
NO.ZK2-OM00501-B
A
Error
Problem Possible cause Investigation method Countermeasure
No.
Effect of line
pressure
fluctuation
(1) Check the set pressure values (1) Widen the hysteresis.
because
(hysteresis) (2) Change the response
hysteresis is too
(2) Check the response time. time setting.
narrow or
response time is
Operation is too short
15 unstable
(chattering).
(1) Check the power supply wiring. (1) Correct the wiring and/or
(2) Check if there is bending stress load resistance
Incorrect wiring/ applied to any parts of the lead (2) Correct the wiring.
broken lead wire wire. (Reduce the tensile force
(Bending radius and tensile force or increase the bending
applied to the lead wire) radius.)
-53-
NO.ZK2-OM00501-B
■Error Indication
This function is to display error location and content when a problem or an error occurs.
Error Name Error Display Error Type Troubleshooting Method
If the error can not be reset after the above measures are taken, then please contact SMC.
-54-
NO.ZK2-OM00501-B
Specification
■Specifications
Rated pressure range 100.0 to -100.0 kPa
Set pressure range 105.0 to -105.0 kPa
Proof pressure 500 kPa
Min. display unit 0.1 kPa
Applicable fluid Air, inert gas and non-flammable gas
Power supply voltage 24 VDC ±10%, ripple max. 10%pk-pk (with polarity protection )
Current consumption 40 mA or less
Switch NPN or PNP open collector
Output OUT1: General-purpose、OUT2: Valve control
Maximum load current 80 mA
Max. applied voltage DC26.4 V
Residual voltage Max. 2 V (at 80 mA load current)
2.5 ms or less (response times available for anti-chattering function: : 20,
Response time
100, 500, 1000 or 2000 ms)
Short circuit protection Provided
Repeatability ±0.2%F.S.±1 digit
Hyster
Hysteresis mode Adjustable (can be set from 0) 1
esis
Display 3 1/2 digits, 7-segment display, color display (Red)
Indicator accuracy +/-2%F.S., +/-1 digit (at ambient temperature 25+/-3 oC)
Indication LED Light when ON OUT1: Green OUT2: Red
Enclosure IP40
Environ Ambient temperature range 5 to 50 oC
ment Withstand voltage 1000 VAC for 1 minute between live parts and case insulation resistance
Insulation resistance 50 M or more at 500 VDC Between lead block and case
Temperature characteristic ±2%F.S. (25 oC reference)
cable 5 cores 3.5, 2 m
Lead wire Sectional area of conductor: 0.15 mm2 (AWG26)
Outside diameter of insulator: 1.0 mm
Standard CE marking, RoHS
1: If the applied pressure fluctuates around the set value, the hysteresis must be set to a value more than the amount of fluctuation or
chattering will occur.
-55-
NO.ZK2-OM00501-B
Revision history
A: Shorten the start-up time
Elimination of copying function
Fixed output of OUT2
B: How to stop energy-saving control
function
Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
© 2011 SMC Corporation All Rights Reserved
NO.ZK2-OM00501-B