Simulation-Horizontal air-cooled heat exchanger forced draft countercurrent to crossflow
Process Data Airside Tubeside
Fluid name Udara Hydraocarbon Mixture
Fluid condition Sens. Gas Sens. Liquid
Total flow rate (kg/s) 180,847 43,600
Weight fraction vapor, In/Out (--) 1,0000 1,0000 0,0000 0,0000
Temperature, In/Out (Deg C) 37,00 87,31 121,70 70,00
Skin temperature, Min/Max (Deg C) 61,95 112,19 62,44 112,81
Wall temperature, Min/Max (Deg C) 61,95 112,19 62,44 112,81
Pressure, In/Out (kPa) 101,33 99,950 0,000 0,000
Pressure drop, Total/Allowed (Pa) (kPa) 1383,9 0,00 5024,1 0,000
Pressure Drop, A-frame reflux section (kPa)
Velocity - Midpoint (m/s) 18,08 290,00
- In/Out (m/s) 271,93 301,89
Film coefficient, Bare/Extended (W/m2-K) 713,90 27,87 2635,1
Mole fraction inert (--)
Heat transfer safety factor (--) 1,0000 1,0000
Fouling resistance (m2-K/W) 0,000000 0,000000
Overall Performance Data
Overall coef, Design/Clean/Actual (W/m2-K) 36,873 / 20,902 / 20,902
Heat duty, Calculated/Specified (MegaWatts) 6,4675 / 0,0000
Effective mean temperature difference (Deg C) 32,98