Models 4528 & 4728 Monitors Model CX-645 Probe: Features
Models 4528 & 4728 Monitors Model CX-645 Probe: Features
The INVALCO Model 4728 S&W Monitor, in conjunction with a Model 4528 Detector and a Model CX-485 Capacitance Probe is a continuous on-line monitor or percent water in a flowing crude oil emulsion stream. This unit displays percent of water in various ranges from 0-5% up to and including 0-20% on a digital LCD indicator. In addition, the Model 4728 provides a 4-20 mA analog output proportional to input range, and a field-adjusted, time-delayed, limit relay for valve control or alarming. The Model 4728 utilizes CMOS circuitry for low power consumption, high reliability, and wide temperature stability.
Features
Real-Time Display and Retransmission of S&W - Allows quick response to upset conditions for downstream controls. Adjustable Delay of Relay Closure - Prevents nuisance alarms and actuator overload. Direct Analog Output from Model 4528 Detector - A 420 mA signal is available from the probe without the need to include the Model 4728 monitor. Nace adaptable - can be modified for use in sour service.
Display Four digit LCD with decimal point. Analog Outputs 4-20 mA, 2-wire internally powered or 4-20 mA, 3-wire externally powered. Relay Output SPDT Relay, 10A, 250 Vac. 1/2 Hp 250 Vac, 10A - 120 Vac resistive. 1/3 Hp 120 Vac, 10A - 30 Vdc resistive. Time Delay 0 to 90 seconds adjustable in 10 second increments. Off-delay approximately 10% of on-delay time. Temperature Range 0F to 160F (-20C to 70C). Enclosures NEMA 4X, weatherproof. NEMA 7, explosion-proof, Class I, Division 1, Groups C and D.
Applications
LACT (Lease Automatic Custody Transfer) Units Detect and reroute oil that has been contaminated by excess S&W. Pipeline Loading Monitor transfer of petroleum/condensate products from offshore loading facilities. Dehydration Equipment Determine and enhance equipment efficiencies. Fuel Oil Monitoring Determine contamination of fuel oil by condensation or other external factors before entry to engine. Storage and Treating Facilities Monitoring and early detection of undesirable conditions as well as interface detection during de-watering of storage tanks.
Telephone: 254/968-2181
FAX 254/968-5709
Model 4728-3WP 4728 Oil/Water Monitor, 0-3% range, Nema 4X - WP Model 4728-5WP 4728 Oil/Water Monitor, 0-5% range, Nema 4X - WP Model 4728-10WP 4728 Oil/Water Monitor, 0-10% range, Nema 4X - WP Model 4728-10XP 4728 Oil/Water Monitor, 0-10% range, Nema 7 - XP Model 4728-20WP 4728 Oil/Water Monitor, 0-20% range, Nema 4X - WP Model 4728-20XP 4728 Oil/Water Monitor, 0-20% range, Nema 7 - XP
Note: Dimensions - Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings.
within the sensor housing. The internal element spacers can be fitted with trimmer rods should it be necessary to adjust the base capacitance. The detector operates from a 12 Vdc regulated power supply from within the associated monitor or customersupplied source. All calibration and adjustments can be accessed through the front panel for ease of use. The Model 4528 detector offers the flexibility of a high and low fail-safe. This fail-safe feature guarantees the quality of the output signal from the detector chassis and will sense over- and under-range conditions as well as an open or shorted probe.
2 SSIS002
Model 4528-10A S&W Detector for CX-645 probe, 0-10% range, 4-20mA output Model 4528-20A S&W Detector for CX-645 probe, 0-20% range, 4-20mA output
Detector/Probe Specifications
Power Supply 12 Vdc @ 130 mA for 0-5 Vdc output. 24 Vdc required for 4-20 mA output. S&W Range 0-5%, 0-10%, and 0-20%. Measurement Accuracy 1.0% of full scale. Resolution/Sensitivity 0.5% of full scale. Probe Material A53 GrB Carbon Steel is standard. Stainless Steel available. Probe Finish Baked-on phenolic two-part epoxy. Probe Sizes/Length 2 I.D. is 17 face-to-face. 3 to 12 I.D. sizes are 32 face-to-face. Process Connections ANSI RF or RTJ Flanges to 600# (all sizes) (others by special order). Threaded MNPT or Grooved (2 and 3). Pressure Ratings As per Flange selection, 1440 psig max. NPT - 1440 psig max. (Victualic grooved - 350 psig). Temperature Range 0F to 180F standard. -20F to 375F optional. Approvals UL/C-UL Explosion-proof certificate for Class I, Div. 1, Groups C and D or Class II, Groups E, F, and G hazardous locations.
10.9" (275) 11.9" (301) 14.0" (355) 16.0" (405) 18.1" (459) Consult Factory
*0F to 180F dimension given. For -20F to 375F dimension add 6.4.
Note: Dimensions - Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings. Issue/Rev. 0.5 (6/04) SSIS002 3
Typical Applications
Percent Water Indication and Set-Point Control In this application the adjustable alarm may be used to operate a diverter valve should the water content exceed a preset percentage. Local indication is provided and an analog output for other indication or control functions is available.
Percent Water Recording In this application the Model 4728 provides local reading on an LCD display and provides an analog output (4-20 mA) to a standard recorder, PLC, or DCS System. This configuration is used to monitor and control Separator and Heater-Treater efficiencies as well as other oil field and industrial applications.
Choose one code selection from each option group to build model number. Note: Model 4528 Detector must be ordered seperately to complete assembly. Probe sizes through 16" are available, please consult factory.
www.fmcinvalco.com
The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. FMC INVALCO Fluid Control Stephenville, TX 76401, Phone: 254/968-2181, 4 SSIT042 SSIS002 Printed in U.S.A. 6/04 FMC INVALCO All rights reserved. FAX: 254/968-5709, Toll Free: 800/468-2526