ENGINE SPECIFICATIONS
Engine Fuel Type Oil Capacity: Crankcase & Oil Filter w/Bypass Oil Filter Oil Type* TK 3.74 No. 2 Diesel fuel under normal conditions 9 quarts (8.6 liters) 10 quarts (9.6 liters) Fill to full mark on dipstick API Type CF-4 or CG-4 or better API Synthetic type CF-4, CG-4 or better after first 500 hours Multigrade Oil Ambient Temperature SAE 5W-30 -22 to +86 F (-30 to +30 C) SAE 10W-30 -4 to +86 F (-20 to +30 C) SAE 10W-40 -4 to +104 F (-20 to +40 C) SAE 15W-40 +5 to +104 F (-15 to +40 C) 1625 25 rpm 2425 25 rpm 35 to 60 psig (241 to 414 kPa) 0.0079 in. (0.20 mm) 0.0079 in. (0.20 mm) Room temperature 14 BTDC 1706 psig (11720 kPa) 10 3 psig (69 21 kPa)shutdown 220 5.0 F (104 3 C)shutdown 180 to 190 F (82 to 88 C) 4 quarts (3.81 liters) with overflow tank 10 psig (69 kPa) Belts to compressor, fans, 12 V alternator, water pump and electric motor (jackshaft)
Oil Viscosity*
Engine rpm: Low Speed Operation High Speed Operation Engine Oil Pressure Intake Valve Clearance Exhaust Valve Clearance Valve Setting Temperature Timing Injection Pump Injection Nozzle Pressure Low Oil Pressure Sensor High Coolant Temperature Sensor Engine Thermostat Coolant System Capacity Radiator Cap Pressure Drive
*Multi-viscosity weight oil with the recommended API classification may be used based on the ambient temperature. The above recommendations are written for mineral oil based lubricants.
BELT TENSION
Tension No. on TK Gauge 204-427 New Belt Field Reset 75 3 70 3 72 3 67 3 55 3 50 3 55 3 50 3 1/2 in. (13 mm) deflection
Engine/Compressor Compressor/Jackshaft (Electric Motor) Compressor/Evaporator Fan/Alternator Alternator/Evaporator Fan Water Pump
NOTE: These are the original factory settings. Because it is difficult to use the TK gauge 204-427 in the field, adjust each belt to allow 1/2 inch (13 mm) deflection at the center of the longest span. NOTE: Belts should be tensioned cold and again tensioned cold after 10 hours of unit running.
ELECTRICAL COMPONENTS
Current Draw (Amps) Resistance at 12.5 Vdc (Ohms) 8.3 1.5 0.15 18 to 25 0.5 to 0.7 0.9 to 1.1 11 to 13 0.657 19 90 to 105 (cranking) 5.68 2.2 50 amp 5 amp (approx.) 2.5 (approx.) 8.5 amp (approx.) 1.5 (approx.)
Glow Plug Fuel Solenoid: Pull In Hold In Pilot Solenoid Starter Motor Damper Solenoid DC Circuit Breakers High Speed Solenoid Electric Standby Reset Solenoid
Voltage/Phase/Frequency
Kilowatts
rpm
5 5 5 4.2 4.2
80 58 58 55 55
25 21 12 12 12.7
3 750
AIR SWITCH
Air Switch Setting 0.7 0.05 in. (17.78 1.3 mm) H2O