ENCE 455 Design of Steel Structures g II.

II Tension Members
C. C F Ph D P E C C. Fu, Ph.D., P.E. Civil and Environmental Engineering Department University of Maryland U i it f M l d

Tension Members
Following subjects are covered: Introduction Design strength g g Net area Staggered fasteners Block shear Design of tension members Threaded rods, pin-connected members Reading: Chapters 3 of Salmon & Johnson AISC Steel Manual Specifications (Part 16) Chapters B (Design Requirements), D (Tension Members), and J (Connections)
2

Introduction
Tension members are structural elements that are subjected to axial tensile forces. Examples include: Members in trusses Cables in cable-stayed and suspension bridges Bracing in frames to resist lateral forces from blast, g , wind, and earthquake
Forth Bridge Queensferry, Scotland Main sections: 5360 ft. Maximum span: 1710(2), 4 spans total Built: 1890
3

Introduction (cont.)
Stresses (f) in axially loaded members are calculated using the equation where P is the load and A is the crosssectional area normal to the load. Design of this component involves calculations for
Tension member (gross area) (g ) Tension member at connection (net area) Gusset plate at connection (net area) Gusset plate at support
4

f =P

Design Strength
At tension member can f il b i b fail by Excessive deformation (yielding) - Excessive deformation is prevented by limiting stresses on the gross section to less than the yield stress. For yielding on the gross section, the nominal strength is: Tn = Fy Ag and t=0.90 0.90 (3.2.1) Fracture - Fracture is avoided by limiting stresses on the net section to less than the ultimate tensile strength. strength For fracture on the net section the nominal section, strength is:

Net Area
Net Area The performance of a tension member is often governed by the response of its connections The AISC Steel connections. Manual introduces a measure of connection performance known as joint efficiency, which is a function of Material M t i l properties (d tilit ) ti (ductility) Fastener spacing Stress concentrations Shear lag (Most important of the four and addressed specifically by the AISC Steel Manual)

Tn = Fu Ae = Fu (UAn) and t=0.75 (3.2.2) where Ae is the effective net area, An is the net area and U is the reduction coefficient (an efficient factor)

Net Area (cont.)


The AISC Steel Manual introduces the concept of effective net area to account for shear lag effects. For bolted connections: Ae = UAn (3.5.1) (3 5 1) For welded connections: Ae = UAg (3.5.3) where U = 1 x 0.9 (3.5.2) L and x is the distance from the plane of the connection to the centroid of the connected member and L is the length of the connection in the direction of the load. (Salmon & Johnson Example 3.5.1 for U)
7

Net Area (cont.)/ x

AISC Steel Manual Salmon & Johnson

Net Area (cont.)/L

Net Area (cont.)/U


For bolted connections, AISC Table D3.1 gives values for U that can be used in lieu of detailed calculation.

10

Net Area (cont.)/U


For welded connections, AISC Table D3.1 lists

Staggered Fasteners
Failure line - When a member has staggered bolt holes, a different approach to finding Ae for the fracture limit state is taken This is because the effective net area is taken. different as the line of fracture changes due to the stagger in the holes. The test for the yielding limit state remains unchanged (the gross area is still the same). For calculation of the effective net area, the Section B2 of the AISC Steel Manual makes use of the product of the plate thickness and the net width. The net width is calculated as
11

s2 wn = wg d + 4g

12

Staggered Fasteners (cont.)

Staggered Fasteners (cont.)


All possible ll bl failure p patterns should be considered. (Example 3.4.2 for An)

13

14

Staggered Fasteners (cont.)

Block Shear
Block shear is an important consideration in the design of steel connections. Consider the figure below that shows the connection of a single angle single-angle tension member. The block is shown shaded.

Figure 3.8.2 Load distribution in plate A (Example 3.8.1)


15 16

Block Shear (cont.)


In this example, the block will fail in shear along ab and tension on bc. The AISC Steel Manual procedure is based on one of the two failure surfaces yielding and the other fracturing.

Block Shear (cont.)


The Th nominal strength in tension is FuAnt f f t i l t th i t i i for fracture and d FyAgt for yielding where the second subscript t denotes area on the tension surface ( bc in the figure above). The yield and ultimate stresses in shear are taken as 60% of the values in tension. The AISC Steel Manual considers two failure modes: One equation to cover all
Shear yield - tension fracture -Tn = 0.6FyAgv + FuAnt Shear fracture - tension yield -Tn = 0.6FuAnv + FuAnt

Both surfaces contribute to the total resistance.

Fracture on the shear surface is accompanied by yielding on the tension surface Fracture on the tension surface is accompanied by p y yielding on the shear surface

(3.6.1) (3.6.2) (AISC J4-5)

Because the limit state is fracture, the equation with the larger of the two fracture values controls where t=0 75 =0.75. (Example 3.9.2 for block shear)
17 18

Tn = 0.6FuAnv + UbsFuAnt 0.6FyAgv + UbsFuAnt

Design of Tension Members


The design of a tension member involves selecting a member from the AISC Steel Manual with adequate
Gross area Net area Slenderness (L/r300 to prevent vibration, etc; does not apply to cables.)

Design of Tension Members (cont.)


Detailing of connections is a critical part of structural steel design. Connections to angles are generally problematic if there are two lines of ll bl ti th t li f bolts. Consider the Gages for Angle figure shown earlier that provides some guidance on sizing angles and bolts.
Gage distance g1 applies when there is one line of bolts Gage distances g2 and g3 apply when there are two lines
20

If the member has a bolted connection, the choice of cross section must account for the area lost to the bolt holes. holes Because the section size is not known in advance, the default values of U are generally used for preliminary design. d i
19

Design of Tension Members


(cont.)/ Thread Rod

Design of Tension Members


(cont.)/ Thread Rod
Threaded Rod Tension on the effective net area Tn = AsFu = 0.75AbFu , where As is the stress area (threaded portion), Ab is the nominal (unthreaded area), area) and 0 75 is a lower bound (conservative) factor 0.75 relating As and Ab. See Section J3.6 of the AISC Steel Manual Specification for details. The design strength of a threaded rod is calculated as

Threaded Rod

Tn =0.75 Tn

(Example 3.10.2 for Rod Design) 3 10 2


21 22

Design of Tension Members


(cont.)/ Pinned Connections
Pinned connections transmit no moment (ideally) and often utilize components machined to tight tolerances (plus, (plus minus 0.001 ). 0 001) The figure shows failure modes for pin-connected members and each failure mode must be checked for design. Specifically, design Specifically the following limit states must be checked.

Design of Tension Members


(cont.)/ Pinned Connections
The following limit states must be checked. Tension on the effective net area

Tn = 0 75(2 t beffFu) where beff = 2t + 0 63 b T 0.75(2 h 0.63


Shear on the effective area Bearing on projected area

(D3-1) (D3 1) (D3 2) (D3-2) (J8-1)

Tn = 0.75(0.6AsfFu) = 0.75{0.6[2t + d/2)] Fu } Tn = 0.75(1.8 ApbFy) = 0.75[1.8 (d t ) Fy ]

where 1.8 ApbFy is based on a deformation limit state under service loads producing stresses of 90% of yield Tension on the gross section

Tn = 0.9(AgFy)
23

(D1-1)
24