The Manning Equation
The Manning Equation
The Manning Equation
The Washington Center for Improving the Quality of Undergraduate Education. All rights reserved. 2005
Overview of Module
2
Culverts are designed to carry a specified discharge and are based on estimates of
runoff. The runoff estimates, in turn, are often based on the magnitude of precipitation
events e.g., the 50-year or 100-year flood; basin characteristics, e.g., drainage area,
topography; and land use. With the estimates of runoff, engineers can determine an
appropriate culvert size. Their goal is to select a diameter that will be just large enough
to carry the required discharge. If the culvert is too small, flooding is possible. If it is too
large, money is wasted.
2 / 3 1/ 2
R s
v 1.49
n
Variables
v = velocity
R = hydraulic radius
s = slope
n = Manning roughness coefficient
Hydraulic Radius: The hydraulic radius for flow in a pipe or open channel is defined as
the cross-sectional area divided by the wetted perimeter. It is not directly measurable,
but it is used frequently in calculations. For pipes or culverts, the cross-sectional area is
equal to the area of a circle (r2), while the wetted perimeter is equal to the
circumference (2r). Therefore, for full pipes, hydraulic radius R = r/2.
Large pipes or culverts are sized by their inside dimension. The pipes are commonly
available with diameters that increase by -foot increments.
ft-1/3 is in sec-m-1/3.
Combining the formulas for Q and v :
R 2 / 3 s1/ 2 2
Q vA 1.49
r
n
The Problem
If you5are given the culvert diameter, the culvert material, and the slope (gradient) of the
culvert, you can use the Manning equation to determine velocity and then discharge.
Answers. Cell
with equation in it.
2r
2
R 2 / 3 s1 / 2 2
Q vA 1.49
r 1.49
n
2/3
1/ 2
s
n
r 2 1.49
r
2
2/3
s1 / 2
n
r 2
Algebra Note: To solve this equation for r, you need to simplify it by combining
the rs. You will get an expression with r8/3. That exponent shows up in the
equation for the relationship between discharge and culvert diameter on Slide 8.
Although this strategy works when the culvert is full, it does not work (the equation
is not correct) when the culvert is not full. Why not? In general, the Manning
equation cannot be inverted when it is applied to open-channel flow. Why not? For
this exercise, we will use trial and error for a full pipe to illustrate the technique and
to explore the relationships between the variables.
Recreate this
spreadsheet.
Design discharge
Closest value that will handle the design flow. Remember, culverts come in
set sizes. Select first size that is greater than given Q.
8
Recreate
the graph below by plotting discharge versus culvert diameter (from slide
7) using the XY (scatter plot) option. Be sure to add the trendline and trendline
equation into the graph.
Change in Discharge with Change in Culvert
Diameter
Note the coefficient look familiar?
Discharge (cfs)
30
2.6667
y = 1.4927x
25
20
15
10
5
0
0
0.5
1.5
2.5
3.5
Because the exponent (2.6667) is larger than 1, you know that the discharge
increases at a faster rate than the culvert diameter.
1. What is the relationship between velocity and culvert diameter? Using the data
that you reproduced in your spreadsheet to determine the culvert diameter
needed to handle 12 cubic feet per second (Slide 7), plot the relationship between
velocity and pipe diameter. Does velocity have the same relationship with culvert
diameter as discharge? Explain your answer.
2. Look at the combined equation on the bottom of slide 4. What happens to
discharge when the slope of the culvert is increased? What happens to
discharge when the roughness coefficient (n) is increased? Begin by answering
qualitatively. Now explore these relationships using your spreadsheet. Which
has a bigger effect on Q: doubling the slope from 0.005 to 0.01, or doubling the
roughness coefficient from 0.011 to 0.022? Express your answer in absolute
terms, and as a proportion. When doubling slope, keep n = 0.011. When doubling
roughness, keep s = 0.005. Use a culvert diameter of 2.0 feet. Compare these
results to your qualitative answers.
10
3. Youve been asked by your boss to install a culvert to handle 25 cfs. She
tells you that the stream gradient is 0.002, and the pipe available is ordinary
concrete (n = 0.013). How big should the culvert be to handle this flow? Use
trial and error, with 0.5-foot increments of change in pipe diameter.
4. Just as you and your crew are loading up to head for the job site, your cell
phone rings, and the supply office tells you that all the concrete culvert was
used on another job. All they have left is corrugated metal culvert with a
diameter of 2.5 feet (n = 0.022). At what slope should you install the 2.5-foot
corrugated metal culvert so that it will handle the discharge of 25 cfs? Again,
you can use trial and error.