ACS580 Product Presentation RevJ
ACS580 Product Presentation RevJ
ACS580 Product Presentation RevJ
ABB Group
4/25/16 | Slide 3
ABB Group
4/25/16 | Slide 4
All essential features built-in. All-inside concept for easy selection, ordering and
installation.
Energy efficiency The highest IE2 drive efficiency class, and support for IE4 efficiency
class motors, total system efficiency motor & drive packages.
The backwards-compatibility with ACS550 and ACS400. Easy to replace existing drives.
ABB Group
4/25/16 | Slide 5
Universal connectivity
Harmonized connector
terminals
ABB Group
4/25/16 | Slide 6
ABB Group
4/25/16 | Slide 7
EMC compatibility
Mitigation of harmonics
ABB Group
4/25/16 | Slide 8
ABB Group
4/25/16 | Slide 9
IP00 as standard
Hardware
ACS580-01
Hardware overview
Frames and powers
ACS580-01 wall-mounted frames
R0
R2
0.75-2.2kW
(1-3 hp)
7.5-11kW
(10-15hp)
ABB Group
4/25/16 | Slide 11
R4
R6
R8
R10
30-37kW
75kW
132-160kW
(40-50hp)
(100hp)
(200hp)
250-355kW
(400-500hp)
R1
R3
R5
R7
R9
R11
3-5.5kW
(3-7.5hp)
15-22kW
45-55kW
90-110kW
200-250kW
400-500kW
(20-30hp)
(60-75hp)
(125-150hp)
(300-350hp)
(600-700hp)
Hardware overview
Example: 15 to 22 kW IP21 single drives
- 23%
ACS580
ABB Group
4/25/16 | Slide 12
Hardware overview
Example: 15 to 22 kW IP55 single drives
- 49%
ACS580
ABB Group
4/25/16 | Slide 13
Hardware overview
Example: 200 and 250 IP21 kW single drives
ACS550
- 65%
ACS580
ABB Group
4/25/16 | Slide 14
Hardware overview
Example: 132 and 160 kW IP55 single drives
ACS550
- 33%
ACS580
ABB Group
4/25/16 | Slide 15
Hardware overview
Overloadability and output current definitions
1.5 Ihd
1.1 Ild
In
Ild
Ihd
ACS550 /
ACS800
ACS580 /
ACS880
Icont
In
In
Ild
Ihd
Ihd
Definition
No overload
ABB Group
4/25/16 | Slide 16
Time
Hardware overview
All essential features included as standard
ABB Group
4/25/16 | Slide 17
Hardware overview
Main circuit
2nd generation
swinging choke
Mitigation of
harmonics enabling
smaller and lighter
design
Gland/conduit box
(R5)
- For cables and
conduits
Hardware overview
Flange mounting (frames R0-R9)
Easier to design
Hardware overview
Ambient conditions
ABB Group
4/25/16 | Slide 21
Hardware overview
Compact IP55 (UL Type 12)
ABB Group
4/25/16 | Slide 22
Packing materials
Environmentally friendly packing
ABB Group
4/25/16 | Slide 23
Hardware
ACS580-04
Hardware overview
Frames and powers
R0
R2
0.75-2.2kW
(1-3 hp)
7.5-11kW
(10-15hp)
ABB Group
4/25/16 | Slide 25
R4
R6
R8
R10
30-37kW
75kW
132-160kW
(40-50hp)
(100hp)
(200hp)
250-355kW
(400-500hp)
R1
R3
R5
R7
R9
R11
3-5.5kW
(3-7.5hp)
15-22kW
45-55kW
90-110kW
200-250kW
400-500kW
(20-30hp)
(60-75hp)
(125-150hp)
(300-350hp)
(600-700hp)
Hardware overview
All essential features included as standard
ABB Group
4/25/16 | Slide 26
Hardware overview
Frames for cabinet installation
ACS580-04
Frame
Power range
(kW)
Height
(mm)
Width
(mm)
Depth
(mm)
R10
250 355
1462
350
505
R11
400 500
1662
350
505
ABB Group
4/25/16 | Slide 27
Hardware overview
Ratings
Pn
In
Imax
PLd
ILd
PHd
IHd
Type designation
Frame
250
505
560
250
485
200
361
ACS580-04-505A-4
R10
315
585
730
315
575
250
429
ACS580-04-585A-4
R10
355
650
730
355
634
250
477
ACS580-04-650A-4
R10
400
725
1020
400
715
315
566
ACS580-04-725A-4
R11
450
820
1020
450
810
355
625
ACS580-04-820A-4
R11
500
880
1100
500
865
400
725*
ACS580-04-880A-4
R11
ABB Group
4/25/16 | Slide 28
Hardware overview
Panel mounting kit as standard
ABB Group
4/25/16 | Slide 29
Hardware overview
Common mode filter as standard
ABB Group
4/25/16 | Slide 31
Hardware
Connectivity and panels
Hardware overview
Standard control connections (R0-R5)
EIA-485 Phloem
2 Analog inputs
- Freely programmable
- Current or voltage
2 Analog outputs
- Freely programmable
- Current or voltage
-Bigger GND and DCOM
terminals
6 Digital inputs
(1 pulse input)
- Freely programmable
- Sinking/sourcing
3 Relay outputs
- Freely programmable
- Form C type
EIA-485
ABB Group
4/25/16 | Slide 33
- Removable module
- Built-in Modbus RTU
Hardware overview
Standard control connections (R6-R11)
2 Analog inputs
- Freely programmable
- Current or voltage
2 Analog outputs
- Freely programmable
- Current or voltage
- Bigger GND and DCOM terminals
EIA-485
- Removable module
- Built-in Modbus RTU
6 Digital inputs
(1 pulse input)
- Freely programmable
- Sinking/sourcing
3 Relay outputs
- Freely programmable
- Form C type
Option slot for C modules
CMOD-01, CMOD-02, CHDI-01
ABB Group
4/25/16 | Slide 34
Hardware overview
I/O and fieldbus options
ABB Group
4/25/16 | Slide 35
External 24 V voltage supply with CMOD01 and -02 for keeping the
communications alive while the main
supply is disconnected
Hardware overview
Multi-functional extension modules and I/O option
Multi-functional extension modules
CMOD-01: 24 VDC/AC input, two relay
outputs, one digital output.
CMOD-02: 24 VDC/AC input and galvanically
isolated PTC input
CPTC-02: ATEX* certified PTC input and 24
VDC/AC input
Digital I/O option
CHDI-01: Six (6) 115VAC or 230VAC
digital inputs
Two relay outputs
ABB Group
4/25/16 | Slide 36
Hardware overview
Assistant control panel
4/25/16 | Slide 37
ABB Group
Hardware overview
Panel options
ACS580 has several different panel options:
4/25/16 | Slide 38
ABB Group
delivered as standard
Hardware options
ACS-AP-W and DriveTune
ABB
4/25/16
Slide 39
Hardware overview
Panel mounting options
ACS580 has two different panel mounting
options:
ABB Group
4/25/16 | Slide 40
Hardware overview
Panel mounting + panel bus adapter option
Hardware overview
Cold configuration adapter (CCA-01)
Drive composer
Drive loader 2
4/25/16 | Slide 42
ABB Group
ACS580
Software
ACS580 standard control program
Software overview
Highlights
Improved monitoring
Monitor most important values graphically with one look from editable home views.
Drive can monitor load to be within nominal range and also report load profile
distribution graphically.
Diagnostic tools
ABB Group
4/25/16 | Slide 44
Group of functions designed to help problem solving and knowing what is limiting or
preventing drive operations.
Energy efficiency
Energy savings up to 10% with built-in energy optimizer, by decreasing losses from
motor over-magnetization.
Motor support
Software overview
Primary settings menu
ABB Group
4/25/16 | Slide 45
Software overview
I/O menu
ABB Group
4/25/16 | Slide 46
Software overview
Diagnostics menu
ABB Group
4/25/16 | Slide 47
Software overview
Diagnostic tools
ABB Group
4/25/16 | Slide 48
Software overview
System info menu
ABB Group
4/25/16 | Slide 49
Software overview
Energy efficiency menu
ABB Group
4/25/16 | Slide 50
Software overview
Backups menu
ABB Group
4/25/16 | Slide 51
Software overview
Parameters menu
Favorites list
4/25/16 | Slide 52
ABB Group
Easier trouble-shooting
Software overview
Home view
ABB Group
4/25/16 | Slide 53
Software overview
Control macros
ABB Group
4/25/16 | Slide 54
3-wire
PID
Hand/PID
Hand/Auto
Simple PID
Alternate
Motor potentiometer
PFC
Software overview
Commissioning and monitoring tool
ABB Group
4/25/16 | Slide 55
Software overview
Motor support
IEC AC motors
NEMA AC motors
Synchronous
reluctance motors
(released later)
ABB Group
4/25/16 | Slide 56
Asynchronous motors
Software overview
Improved motor control
ABB Group
4/25/16 | Slide 57
Flying start for both motor control modes to catch running motors
Two selectable flux braking levels allow ramp stops without resistors
by using the motor effectively as a one
DC hold control for vector and scalar mode to keep the shaft locked
when drive is stopped
Software overview
Connectivity
ABB Group
4/25/16 | Slide 58
PROFIBUS DP
PROFINET
Modbus/RTU
Modbus/TCP
EtherNet/IP
ACS580 catalog
Technical guide 3:
EMC compliant installation and configuration for a powe
r drive system
Technical guide 6: Guide to harmonics with AC drives
ABB Group
4/25/16 | Slide 62
ABB Group
4/25/16 | Slide 63