Metering
Metering
Metering
MEASUREMENT
Munawar Javaid
Nandpur Gas Field
WHY MEASUREMENT
Gas sales
Plant applications
FLUID
A substance that can easily change its shape i.e.,
liquid or gas.
TYPES OF FLUIDS
Q = U x A
MM 1000x1000=1000000=million
S for Standard
D for day
Unit for measurement of heating or energy value
of gas is MMBTU(million British thermal unit)
TYPES OF FLOW
Laminar or smooth flow:
-Constant, smooth fluid motion
- Occurs at low velocities
-Occurs at low Reynolds no.
Turbulent Flow:
-Swirls ,eddies makes flow turbulent.
- Occurs at high velocities
- occurs at high Reynold no.
REYNOLD NUMBER
Simple
Cheap
Accurate
Used for liquids and gases
Standards are well established and
comprehensive
Wide range of flow rates
DISADVANTAGE
causes pressure drop
Affected by upstream swirls
Requires single phase flow
Requires turbulent flow profile( Reynolds No
greater than 4000)
ORIFICE METER APPARATUS
Components used in orifice meters are
Orifice plate holder
Orifice plate
hw
= Differential pressure in inches of water at 60 F (1
psi=27.4 inch of water)
Pf
= Static pressure in psia
C
= Orifice flow constant
Fr = 1 + b /hw Pf
Fpb = 14.73 / Pb
Ftf = 520/Tf+460
SPECIFIC GRAVITY FACTOR, Fg:
The specific gravity ) factor Fgr is applied to
change from a real gas density of 1.0 to the specific
gravity of flowing gas .
Fg = 1/G
Ft= 226.29/99.15+211.9G-Kt
Kt=Mc+1.681 Mn