Ss Garbage Chutes
Ss Garbage Chutes
Ss Garbage Chutes
REPORT
SUBMITTED BY:
SAHIL MALIK
16BAR1066
SUBMITTED TO:
AR. SHADAB
AR. VIVEK
Garbage Chutes
Intake Door
• Intake door are self-closing, with a positive latching system.
• The front is fabricated of polished stainless steel with matt
steel backs.
• Steel angle frame with 3-1/2” steel extensions.
• Integral polished stainless steel trim, with top side embossed,
designating the use of the chute.
• Pivot type hinge welded to the door frame
•Door equipped with chrome plated kye locking “C” handle
latching assembly.
Material of construction
1, Stainless steel S.S. 430 / S.S. 304
2, GI - Galvanized Iron
3, M.S. ORCRC
Thickness of chutes - 1mm/ 1.2mm / 1.6mm as per diameter.
Venting
1. This for removing foul smells and gases generated in
garbage chute.
2. Vents are made the same diameter or reducing diameter
of chute and extend 4ft above roof of the building.
3. Exhaust system in the top to remove decomposed smell
and gases with a fan of average speed.
4. 300 CFM-900 CFM depends on the number oors.
5. Ventilation is operated automatically (Time base) by electrically
operated control penal.
Discharge
• Chute shall directly discharge into trolley or compactor.
• Diversion shall not to be allowed. Max diversion of 15 with
vertical allowed as per codes.
maintain hygiene.
ROOF FAN
SLAB
DOOR
FRAME
1. Normal Cleaning
• This Cleaning has been done by normal water coming from
STRUCTURAL
overhead water tank and it is operated and controlled by
electrically operated valve, This valve is tted at top of chute
BRACKET
FLOOR SLAB
DIA,OF CHUTE
SPRINKLER
and outlet of water tank. this system operated on manual mode
as well as automatic modealso.
HEAD
INTAKE
DOOR
GARBAGE
TROLLEY well as automatic mode also.
GROUND
FLOOR
Material of construction
• Room shall be air tight non ventilated room.
• No windows or louvers shall be provide in room.
• Provide wall tiles (min. 1.8mtr. high) & oor tiles.
• Floor to have proper slope with drainage.
•Provide proper single phase power point with suf cient Lighting
arrangement in Garbage Room.
• Provide outside opening ush door to garbage room.
• Chute duct slab to be closed in garbage room after installation
of chute.
Garbage Room Sizes Required
TYPE OF CHUTE SIZE OF GARBAGE ROOM
- L W H
STANDARD CHUTE 1500mm 1500mm 2500mm
SEGREGATION CHUTE 2100mm 1500mm 2500mm
ELECTRICAL VENT PIPE
VALVE WITH
SANITATION
EXHAUST FAN
R.L.
CLEANING
SPRINKLER
HOPPER WITH
INTAKE DOOR INTAKEDOOR
MOUNTING
BRACKET
F.L.
900MM
F.L.
DISCHARGE
DOOR
GARBAGEROOM
Segregation System
As per Municipal norms segregation of “DRY”(Recycling)& “WET”
(Biodegradable) garbage is required and shall be collected in
separate collection Bins.
We provide facilitates to segregate and collection of garbage by
using one chute.
It is fully automatic and one user at a time.
• Busy indicator and hoppers remain locked for all other oors.
WET
GARBAG DRY WET
GARBAG DRY
TROLLEY
E TROLLEY
E