Chapter 5 Bell Delware Method UTAS
Chapter 5 Bell Delware Method UTAS
Chapter 5 Bell Delware Method UTAS
ENCH3113
Chapter 5
Dr
Rajan
Chapter 5
2
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Introduction
• In 1950 at Delaware University, a research program
in shell-and-tube heat exchangers was developed
with the sponsorship of the Tubular Exchanger
Manufacturers Association (TEMA) and the
American Society of Mechanical Engineers (ASME).
5
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Cross Flow Area
• Sm is the minimum
cross-sectional flow
area in the tube bank.
• In square or triangular
arrays, this is the free
area available for
normal flow calculated
at the central plane of
a tube row.
6
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Heat Transfer Coefficient and Distance
• It is known that in laminar flow the heat transfer
coefficient decreases with increasing distance
from the start of heating.
8
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Other Correction Factors for Tubular
Heat Exchangers
Data corresponding to an ideal tube bank must
be corrected to take into account the following
when used in real heat exchanger design:
•bypass streams
•baffle windows and
•effects of leakage
9
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Bypass Effects
• The fraction of the total flow bypassing the
bundle could be as high as 75 percent in
laminar flow and 50 percent in turbulent flow,
with a consequent reduction in heat transfer
coefficient and pressure drop.
10
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Effect of Sealing Strips
11
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Effect of the Baffle Window
• The effect of the baffle window on heat
transfer and pressure drop will be analyzed
separately.
12
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
• Pressure drop corresponding to a cross-flow
section, which is the portion of the tube bank
limited by the edges of two consecutive
baffles.
13
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Pressure Drop Through a Baffle
Window in Laminar Flow (Re < 100)
• The fluid velocity is not uniform
throughout the window, and it has
components in the directions parallel and
normal to the tubes.
15
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Effect of leakage on pressure drop
• Owing to the leakage existing between baffles and
tubes and between baffles and shell, both pressure
drop and heat transfer coefficients differ from the
values of an ideal bank.
16
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Pressure Drop
Bell determined the ratio
between ΔpL (pressure
drop for a heat exchanger
with leakage) and ΔpNL
(pressure drop for a similar
heat exchanger with the
same total flow but
without leakage).
17
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
The shell-side heat transfer coefficient
of a heat exchanger
18
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-
Total shell-side pressure drop
19
University of Technology and Applied Sciences جامعة التقنية والعلوم التطبيقية-