Showing 1–8 of 8 results for author: Adragna, P

.
  1. arXiv:1012.4305  [pdf, ps, other

    physics.ins-det hep-ex

    A Layer Correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test

    Authors: E. Abat, J. M. Abdallah, T. N. Addy, P. Adragna, M. Aharrouche, A. Ahmad, T. P. A. Akesson, M. Aleksa, C. Alexa, K. Anderson, A. Andreazza, F. Anghinolfi, A. Antonaki, G. Arabidze, E. Arik, T. Atkinson, J. Baines, O. K. Baker, D. Banfi, S. Baron, A. J. Barr, R. Beccherle, H. P. Beck, B. Belhorma, P. J. Bell , et al. (460 additional authors not shown)

    Abstract: A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in… ▽ More

    Submitted 12 May, 2011; v1 submitted 20 December, 2010; originally announced December 2010.

    Comments: 36 pages, 12 figures, accepted by JINST

    Report number: ATL-COM-CAL-2010-006

    Journal ref: JINST 6 (2011) P06001

  2. arXiv:1002.0270  [pdf

    cs.OH

    Inertial tolerancing and capability indices in an assembly production

    Authors: Pierre-Antoine Adragna, Maurice Pillet, Fabien Formosa, Serge Samper

    Abstract: Traditional tolerancing considers the conformity of a batch when the batch satisfies the specifications. The characteristic is considered for itself and not according to its incidence in the assembly. Inertial tolerancing proposes another alternative of tolerancing in order to guarantee the final assembly characteristic. The inertia I2 = \sqrt{δ^2 + σ^2} is not toleranced by a tolerance interval… ▽ More

    Submitted 1 February, 2010; originally announced February 2010.

    Journal ref: Revue Internationale d Ingenierie Numerique 2, 1-2 (2006) 71-88

  3. A proposition of 3D inertial tolerancing to consider the statistical combination of the location and orientation deviations

    Authors: Pierre-Antoine Adragna, Serge Samper, Maurice Pillet

    Abstract: Tolerancing of assembly mechanisms is a major interest in the product life cycle. One can distinguish several models with growing complexity, from 1-dimensional (1D) to 3-dimensional (3D) (including form deviations), and two main tolerancing assumptions, the worst case and the statistical hypothesis. This paper presents an approach to 3D statistical tolerancing using a new acceptance criterion.… ▽ More

    Submitted 1 February, 2010; originally announced February 2010.

    Journal ref: International Journal of Product Development 10, 1-2 (2010) 26-45(20)

  4. arXiv:1002.0251  [pdf

    cs.OH

    Caractérisation des défauts d'une surface sphérique par décomposition modale

    Authors: Hugues Favreliere, Serge Samper, Pierre-Antoine Adragna

    Abstract: The [ISO 1101] standard specifies the form errors with geometrical tolerances using the zone concept.To complete this concept, we present a generic method which adapts to any geometry and allows to describe any kind of errors. Thus,we can dissociate the part errors according to reference categories: position, orientation,form, waviness and roughnesses. Starting from a cloud of poinds representin… ▽ More

    Submitted 1 February, 2010; originally announced February 2010.

  5. Modeling of 2D and 3D Assemblies Taking Into Account Form Errors of Plane Surfaces

    Authors: Serge Samper, Pierre-Antoine Adragna, Hugues Favreliere, Maurice Pillet

    Abstract: The tolerancing process links the virtual and the real worlds. From the former, tolerances define a variational geometrical language (geometric parameters). From the latter, there are values limiting those parameters. The beginning of a tolerancing process is in this duality. As high precision assemblies cannot be analyzed with the assumption that form errors are negligible, we propose to apply… ▽ More

    Submitted 1 February, 2010; originally announced February 2010.

    Journal ref: Journal of Computing and Information Science in Engineering 9, 4 (2009) 041005

  6. arXiv:0901.0512  [pdf

    hep-ex

    Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics

    Authors: The ATLAS Collaboration, G. Aad, E. Abat, B. Abbott, J. Abdallah, A. A. Abdelalim, A. Abdesselam, O. Abdinov, B. Abi, M. Abolins, H. Abramowicz, B. S. Acharya, D. L. Adams, T. N. Addy, C. Adorisio, P. Adragna, T. Adye, J. A. Aguilar-Saavedra, M. Aharrouche, S. P. Ahlen, F. Ahles, A. Ahmad, H. Ahmed, G. Aielli, T. Akdogan , et al. (2587 additional authors not shown)

    Abstract: A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on… ▽ More

    Submitted 14 August, 2009; v1 submitted 28 December, 2008; originally announced January 2009.

  7. A PMT-Block test bench

    Authors: P. Adragna, A. Antonaki, I. Boudagov, V. Cavasinni, D. Costanzo, T. Del Prete, A. Dotti, D. Fassouliotis, V. Giakoumopoulou, N. Giokaris, C. Guicheney, E. Karali, J. Khubua, M. Lebessi, A. Lupi, A. Manoussakis, E. Mazzoni, I. Minashvili, M. Morphi, G. F. Pagani, R. Paoletti, D. Rizzi, C. Roda, F. Sarri, Ath. Staveris-Polykalas , et al. (8 additional authors not shown)

    Abstract: The front-end electronics of the ATLAS hadronic calorimeter (Tile Cal) is housed in a unit, called {\it PMT-Block}. The PMT-Block is a compact instrument comprising a light mixer, a PMT together with its divider and a {\it 3-in-1} card, which provides shaping, amplification and integration for the signals. This instrument needs to be qualified before being assembled on the detector. A PMT-Block… ▽ More

    Submitted 8 May, 2006; originally announced May 2006.

    Comments: 23 pages, 10 figures

    Journal ref: Nucl.Instrum.Meth. A564 (2006) 597-607

  8. arXiv:physics/0405154  [pdf, ps, other

    physics.ins-det cs.PF cs.SE

    The ATLAS Tile Calorimeter Test Beam Monitoring Program

    Authors: Paolo Adragna, Andrea Dotti, Chiara Roda

    Abstract: During 2003 test beam session for ATLAS Tile Calorimeter a monitoring program has been developed to ease the setup of correct running condition and the assessment of data quality. The program has been built using the Online Software services provided by the ATLAS Online Software group. The first part of this note contains a brief overview of these services followed by the full description of Til… ▽ More

    Submitted 29 May, 2004; originally announced May 2004.

    Comments: 11 pages, 8 figures, ATLAS TILECAL Note

    Report number: ATL-TILECAL-2004-002