Design and Performance of the Prototype Schwarzschild-Couder Telescope Camera
Authors:
Colin B. Adams,
Giovanni Ambrosi,
Michelangelo Ambrosio,
Carla Aramo,
Timothy Arlen,
Wystan Benbow,
Bruna Bertucci,
Elisabetta Bissaldi,
Jonathan Biteau,
Massimiliano Bitossi,
Alfonso Boiano,
Carmela Bonavolontà,
Richard Bose,
Aurelien Bouvier,
Mario Buscemi,
Aryeh Brill,
Anthony M. Brown,
James H. Buckley,
Rodolfo Canestrari,
Massimo Capasso,
Mirco Caprai,
Paolo Coppi,
Corbin E. Covault,
Davide Depaoli,
Leonardo Di Venere
, et al. (64 additional authors not shown)
Abstract:
The prototype Schwarzschild-Couder Telescope (pSCT) is a candidate for a medium-sized telescope in the Cherenkov Telescope Array. The pSCT is based on a novel dual mirror optics design which reduces the plate scale and allows for the use of silicon photomultipliers as photodetectors.
The prototype pSCT camera currently has only the central sector instrumented with 25 camera modules (1600 pixels)…
▽ More
The prototype Schwarzschild-Couder Telescope (pSCT) is a candidate for a medium-sized telescope in the Cherenkov Telescope Array. The pSCT is based on a novel dual mirror optics design which reduces the plate scale and allows for the use of silicon photomultipliers as photodetectors.
The prototype pSCT camera currently has only the central sector instrumented with 25 camera modules (1600 pixels), providing a 2.68$^{\circ}$ field of view (FoV). The camera electronics are based on custom TARGET (TeV array readout with GSa/s sampling and event trigger) application specific integrated circuits. Field programmable gate arrays sample incoming signals at a gigasample per second. A single backplane provides camera-wide triggers. An upgrade of the pSCT camera is in progress, which will fully populate the focal plane. This will increase the number of pixels to 11,328, the number of backplanes to 9, and the FoV to 8.04$^{\circ}$. Here we give a detailed description of the pSCT camera, including the basic concept, mechanical design, detectors, electronics, current status and first light.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
Prototype Schwarzschild-Couder Telescope for the Cherenkov Telescope Array: Commissioning the Optical System
Authors:
C. B. Adams,
G. Ambrosi,
M. Ambrosio,
C. Aramo,
P. I. Batista,
W. Benbow,
B. Bertucci,
E. Bissaldi,
M. Bitossi,
A. Boiano,
C. Bonavolontà,
R. Bose,
A. Brill,
J. H. Buckley,
R. A. Cameron,
R. Canestrari,
M. Capasso,
M. Caprai,
C. E. Covault,
D. Depaoli,
L. Di Venere,
M. Errando,
S. Fegan,
Q. Feng,
E. Fiandrini
, et al. (47 additional authors not shown)
Abstract:
A prototype Schwarzschild-Couder Telescope (pSCT) has been constructed at the Fred Lawrence Whipple Observatory as a candidate for the medium-sized telescopes of the Cherenkov Telescope Array Observatory (CTAO). CTAO is currently entering early construction phase of the project and once completed it will vastly improve very high energy gamma-ray detection component in multi-wavelength and multi-me…
▽ More
A prototype Schwarzschild-Couder Telescope (pSCT) has been constructed at the Fred Lawrence Whipple Observatory as a candidate for the medium-sized telescopes of the Cherenkov Telescope Array Observatory (CTAO). CTAO is currently entering early construction phase of the project and once completed it will vastly improve very high energy gamma-ray detection component in multi-wavelength and multi-messenger observations due to significantly improved sensitivity, angular resolution and field of view comparing to the current generation of the ground-based gamma-ray observatories H.E.S.S., MAGIC and VERITAS. The pSCT uses a dual aspheric mirror design with a $9.7$ m primary mirror and $5.4$ m secondary mirror, both of which are segmented. The Schwarzschild-Couder (SC) optical system (OS) selected for the prototype telescope achieves wide field of view of $8$ degrees and simultaneously reduces the focal plane plate scale allowing an unprecedented compact ($0.78$m diameter) implementation of the high-resolution camera ($6$mm/ $0.067$deg per imaging pixel with $11,328$ pixels) based on the silicon photo-multipliers (SiPMs). The OS of the telescope is designed to eliminate spherical and comatic aberrations and minimize astigmatism to radically improve off-axis imaging and consequently angular resolution across all the field of view with respect to the conventional single-mirror telescopes. Fast and high imaging resolution OS of the pSCT comes with the challenging submillimeter-precision custom alignment system, which was successfully demonstrated with an on-axis point spread function (PSF) of $2.9$ arcmin prior to the first-light detection of the Crab Nebula in 2020. Ongoing and future commissioning activities are reported.
△ Less
Submitted 14 October, 2021;
originally announced October 2021.
-
A neural network classifier for electron identification on the DAMPE experiment
Authors:
David Droz,
Andrii Tykhonov,
Xin Wu,
Francesca Alemanno,
Giovanni Ambrosi,
Enrico Catanzani,
Margherita Di Santo,
Dimitrios Kyratzis,
Stephan Zimmer
Abstract:
The Dark Matter Particle Explorer (DAMPE) is a space-borne particle detector and cosmic ray observatory in operation since 2015, designed to probe electrons and gamma rays from a few GeV to 10 TeV energy, as well as cosmic protons and nuclei up to 100 TeV. Among the main scientific objectives is the precise measurement of the cosmic electron+positron flux, which due to the very large proton backgr…
▽ More
The Dark Matter Particle Explorer (DAMPE) is a space-borne particle detector and cosmic ray observatory in operation since 2015, designed to probe electrons and gamma rays from a few GeV to 10 TeV energy, as well as cosmic protons and nuclei up to 100 TeV. Among the main scientific objectives is the precise measurement of the cosmic electron+positron flux, which due to the very large proton background in orbit requires a powerful particle identification method. In the past decade, the field of machine learning has provided us the needed tools. This paper presents a neural network based approach to cosmic electron identification and proton rejection and showcases its performances based on simulated Monte Carlo data. The neural network reaches significantly lower background than the classical, cut-based method for the same detection efficiency, especially at highest energies. A good matching between simulations and real data completes the picture.
△ Less
Submitted 11 May, 2021; v1 submitted 10 February, 2021;
originally announced February 2021.
-
The FragmentatiOn Of Target Experiment (FOOT) and its DAQ system
Authors:
Silvia Biondi,
Andrey Alexandrov,
Behcet Alpat,
Giovanni Ambrosi,
Stefano Argirò,
Rau Arteche Diaz,
Nazarm Bartosik,
Giuseppe Battistoni,
Nicola Belcari,
Elettra Bellinzona,
Maria Giuseppina Bisogni,
Graziano Bruni,
Pietro Carra,
Piergiorgio Cerello,
Esther Ciarrocchi,
Alberto Clozza,
Sofia Colombi,
Giovanni De Lellis,
Alberto Del Guerra,
Micol De Simoni,
Antonia Di Crescenzo,
Benedetto Di Ruzza,
Marco Donetti,
Yunsheng Dong,
Marco Durante
, et al. (70 additional authors not shown)
Abstract:
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experim…
▽ More
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experiment has been developed in such a way that the experimental setup is easily movable and fits the space limitations of the experimental and treatment rooms available in hadrontherapy treatment centers, where most of the data takings are carried out. The Trigger and Data Acquisition system needs to follow the same criteria and it should work in different laboratories and in different conditions. It has been designed to acquire the largest sample size with high accuracy in a controlled and online-monitored environment. The data collected are processed in real-time for quality assessment and are available to the DAQ crew and detector experts during data taking.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
Tracker-In-Calorimeter (TIC): a calorimetric approach to tracking gamma rays in space experiments
Authors:
O. Adriani,
G. Ambrosi,
P. Azzarello,
A. Basti,
E. Berti,
B. Bertucci,
G. Bigongiari,
L. Bonechi,
M. Bongi,
S. Bottai,
M. Brianzi,
P. Brogi,
G. Castellini,
E. Catanzani,
C. Checchia,
R. D'Alessandro,
S. Detti,
M. Duranti,
N. Finetti,
V. Formato,
M. Ionica,
P. Maestro,
F. Maletta,
P. S. Marrocchesi,
N. Mori
, et al. (11 additional authors not shown)
Abstract:
A multi-messenger, space-based cosmic ray detector for gamma rays and charged particles poses several design challenges due to the different instrumental requirements for the two kind of particles. Gamma-ray detection requires layers of high Z materials for photon conversion and a tracking device with a long lever arm to achieve the necessary angular resolution to separate point sources; on the co…
▽ More
A multi-messenger, space-based cosmic ray detector for gamma rays and charged particles poses several design challenges due to the different instrumental requirements for the two kind of particles. Gamma-ray detection requires layers of high Z materials for photon conversion and a tracking device with a long lever arm to achieve the necessary angular resolution to separate point sources; on the contrary, charge measurements for atomic nuclei requires a thin detector in order to avoid unwanted fragmentation, and a shallow instrument so to maximize the geometric factor. In this paper, a novel tracking approach for gamma rays which tries to reconcile these two conflicting requirements is presented. The proposal is based on the Tracker-In-Calorimeter (TIC) design that relies on a highly-segmented calorimeter to track the incident gamma ray by sampling the lateral development of the electromagnetic shower at different depths. The effectiveness of this approach has been studied with Monte Carlo simulations and has been validated with test beam data of a detector prototype.
△ Less
Submitted 22 October, 2020; v1 submitted 4 August, 2020;
originally announced August 2020.
-
Penetrating particle ANalyzer (PAN)
Authors:
X. Wu,
G. Ambrosi,
P. Azzarello,
B. Bergmann,
B. Bertucci,
F. Cadoux,
M. Campbell,
M. Duranti,
M. Ionica,
M. Kole,
S. Krucker,
G. Maehlum,
D. Meier,
M. Paniccia,
L. Pinsky,
C. Plainaki,
S. Pospisil,
T. Stein,
P. A. Thonet,
N. Tomassetti,
A. Tykhonov
Abstract:
PAN is a scientific instrument suitable for deep space and interplanetary missions. It can precisely measure and monitor the flux, composition, and direction of highly penetrating particles ($> \sim$100 MeV/nucleon) in deep space, over at least one full solar cycle (~11 years). The science program of PAN is multi- and cross-disciplinary, covering cosmic ray physics, solar physics, space weather an…
▽ More
PAN is a scientific instrument suitable for deep space and interplanetary missions. It can precisely measure and monitor the flux, composition, and direction of highly penetrating particles ($> \sim$100 MeV/nucleon) in deep space, over at least one full solar cycle (~11 years). The science program of PAN is multi- and cross-disciplinary, covering cosmic ray physics, solar physics, space weather and space travel. PAN will fill an observation gap of galactic cosmic rays in the GeV region, and provide precise information of the spectrum, composition and emission time of energetic particle originated from the Sun. The precise measurement and monitoring of the energetic particles is also a unique contribution to space weather studies. PAN will map the flux and composition of penetrating particles, which cannot be shielded effectively, precisely and continuously, providing valuable input for the assessment of the related health risk, and for the development of an adequate mitigation strategy. PAN has the potential to become a standard on-board instrument for deep space human travel.
PAN is based on the proven detection principle of a magnetic spectrometer, but with novel layout and detection concept. It will adopt advanced particle detection technologies and industrial processes optimized for deep space application. The device will require limited mass (~20 kg) and power (~20 W) budget. Dipole magnet sectors built from high field permanent magnet Halbach arrays, instrumented in a modular fashion with high resolution silicon strip detectors, allow to reach an energy resolution better than 10\% for nuclei from H to Fe at 1 GeV/n.
△ Less
Submitted 21 January, 2019; v1 submitted 14 January, 2019;
originally announced January 2019.
-
In-flight performance of the DAMPE silicon tracker
Authors:
A. Tykhonov,
G. Ambrosi,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
B. Bertucci,
A. Bolognini,
F. Cadoux,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
Y. F. Dong,
M. Duranti,
D. D'Urso,
R. R. Fan,
P. Fusco,
V. Gallo,
M. Gao,
F. Gargano,
S. Garrappa,
K. Gong,
M. Ionica,
D. La Marra,
F. Loparco
, et al. (17 additional authors not shown)
Abstract:
DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector, successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientific goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mech…
▽ More
DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector, successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientific goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mechanisms of cosmic-ray particles, and gamma-ray astronomy. DAMPE consists of four sub-detectors: a plastic scintillator strip detector, a Silicon-Tungsten tracKer-converter (STK), a BGO calorimeter and a neutron detector. The STK is composed of six double layers of single-sided silicon micro-strip detectors interleaved with three layers of tungsten for photon conversions into electron-positron pairs. The STK is a crucial component of DAMPE, allowing to determine the direction of incoming photons, to reconstruct tracks of cosmic rays and to estimate their absolute charge (Z). We present the in-flight performance of the STK based on two years of in-flight DAMPE data, which includes the noise behavior, signal response, thermal and mechanical stability, alignment and position resolution.
△ Less
Submitted 27 June, 2018;
originally announced June 2018.
-
Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data
Authors:
A. Tykhonov,
G. Ambrosi,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
B. Bertucci,
A. Bolognini,
F. Cadoux,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
Y. F. Dong,
M. Duranti,
D. D'Urso,
R. R. Fan,
P. Fusco,
V. Gallo,
M. Gao,
F. Gargano,
S. Garrappa,
K. Gong,
M. Ionica,
D. La Marra,
S. J. Lei
, et al. (18 additional authors not shown)
Abstract:
The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be…
▽ More
The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m$^2$. Silicon planes are interleaved with three layers of tungsten plates, resulting in about one radiation length of material in the tracker. Internal alignment parameters of the tracker have been determined on orbit, with non-showering protons and helium nuclei. We describe the alignment procedure and present the position resolution and alignment stability measurements.
△ Less
Submitted 22 March, 2018; v1 submitted 7 December, 2017;
originally announced December 2017.
-
The DArk Matter Particle Explorer mission
Authors:
J. Chang,
G. Ambrosi,
Q. An,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
B. Bertucci,
M. S. Cai,
M. Caragiulo,
D. Y. Chen,
H. F. Chen,
J. L. Chen,
W. Chen,
M. Y. Cui,
T. S. Cui,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
J. N. Dong,
T. K. Dong,
Y. F. Dong,
Z. X. Dong,
G. Donvito,
D. Droz
, et al. (139 additional authors not shown)
Abstract:
The DArk Matter Particle Explorer (DAMPE), one of the four scientific space science missions within the framework of the Strategic Pioneer Program on Space Science of the Chinese Academy of Sciences, is a general purpose high energy cosmic-ray and gamma-ray observatory, which was successfully launched on December 17th, 2015 from the Jiuquan Satellite Launch Center. The DAMPE scientific objectives…
▽ More
The DArk Matter Particle Explorer (DAMPE), one of the four scientific space science missions within the framework of the Strategic Pioneer Program on Space Science of the Chinese Academy of Sciences, is a general purpose high energy cosmic-ray and gamma-ray observatory, which was successfully launched on December 17th, 2015 from the Jiuquan Satellite Launch Center. The DAMPE scientific objectives include the study of galactic cosmic rays up to $\sim 10$ TeV and hundreds of TeV for electrons/gammas and nuclei respectively, and the search for dark matter signatures in their spectra. In this paper we illustrate the layout of the DAMPE instrument, and discuss the results of beam tests and calibrations performed on ground. Finally we present the expected performance in space and give an overview of the mission key scientific goals.
△ Less
Submitted 14 September, 2017; v1 submitted 26 June, 2017;
originally announced June 2017.
-
Charge reconstruction study of the DAMPE Silicon-Tungsten Tracker with ion beams
Authors:
Rui Qiao,
Wen-Xi Peng,
Dong-Ya Guo,
Hao Zhao,
Huan-Yu Wang,
Ke Gong,
Fei Zhang,
Xin Wu,
Phillip Azzarello,
Andrii Tykhonov,
Ruslan Asfandiyarov,
Valentina Gallo,
Giovanni Ambrosi,
Nicola Mazziotta,
Ivan De Mitri
Abstract:
The DArk Matter Particle Explorer (DAMPE) is one of the four satellites within Strategic Pioneer Research Program in Space Science of the Chinese Academy of Science (CAS). DAMPE can detect electrons, photons in a wide energy range (5 GeV to 10 TeV) and ions up to iron (100GeV to 100 TeV). Silicon-Tungsten Tracker (STK) is one of the four subdetectors in DAMPE, providing photon-electron conversion,…
▽ More
The DArk Matter Particle Explorer (DAMPE) is one of the four satellites within Strategic Pioneer Research Program in Space Science of the Chinese Academy of Science (CAS). DAMPE can detect electrons, photons in a wide energy range (5 GeV to 10 TeV) and ions up to iron (100GeV to 100 TeV). Silicon-Tungsten Tracker (STK) is one of the four subdetectors in DAMPE, providing photon-electron conversion, track reconstruction and charge identification for ions. Ion beam test was carried out in CERN with 60GeV/u Lead primary beams. Charge reconstruction and charge resolution of STK detectors were investigated.
△ Less
Submitted 27 May, 2017;
originally announced May 2017.
-
Design of the readout electronics for the DAMPE Silicon Tracker detector
Authors:
Fei Zhang,
Wen-Xi Peng,
Ke Gong,
Di Wu,
Yi-Fan Dong,
Rui Qiao,
Rui-Rui Fan,
Jin-Zhou Wang,
Huan-Yu Wang,
Xin Wu,
Daniel La Marra,
Philipp Azzarello,
Valentina Gallo,
Giovanni Ambrosi,
Andrea Nardinocchi
Abstract:
The Silicon Tracker (STK) is a detector of the DAMPE satellite to measure the incidence direction of high energy cosmic ray. It consists of 6 X-Y double layers of silicon micro-strip detectors with 73,728 readout channels. It's a great challenge to readout the channels and process the huge volume of data in the critical space environment. 1152 Application Specific Integrated Circuits (ASIC) and 38…
▽ More
The Silicon Tracker (STK) is a detector of the DAMPE satellite to measure the incidence direction of high energy cosmic ray. It consists of 6 X-Y double layers of silicon micro-strip detectors with 73,728 readout channels. It's a great challenge to readout the channels and process the huge volume of data in the critical space environment. 1152 Application Specific Integrated Circuits (ASIC) and 384 ADCs are adopted to readout the detector channels. The 192 Tracker Front-end Hybrid (TFH) modules and 8 identical Tracker Readout Board (TRB) modules are designed to control and digitalize the front signals. In this paper, the design of the readout electronics for STK and its performance will be presented in detail.
△ Less
Submitted 16 June, 2016;
originally announced June 2016.
-
SiPM and front-end electronics development for Cherenkov light detection
Authors:
G. Ambrosi,
F. Acerbi,
E. Bissaldi,
A. Ferri,
F. Giordano,
A. Gola,
M. Ionica,
R. Paoletti,
C. Piemonte,
G. Paternoster,
D. Simone,
V. Vagelli,
G. Zappala,
N. Zorzi
Abstract:
The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6$\times$6 mm$^2$. The camera houses about two thousands electronics channels and is both light and compact. In this framework, a R&D program for the development of SiPMs suitable for Cherenkov light detect…
▽ More
The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6$\times$6 mm$^2$. The camera houses about two thousands electronics channels and is both light and compact. In this framework, a R&D program for the development of SiPMs suitable for Cherenkov light detection (so called NUV SiPMs) is ongoing. Different photosensors have been produced at Fondazione Bruno Kessler (FBK), with different micro-cell dimensions and fill factors, in different geometrical arrangements. At the same time, INFN is developing front-end electronics based on the waveform sampling technique optimized for the new NUV SiPM. Measurements on 1$\times$1 mm$^2$, 3$\times$3 mm$^2$, and 6$\times$6 mm$^2$ NUV SiPMs coupled to the front-end electronics are presented
△ Less
Submitted 10 September, 2015;
originally announced September 2015.
-
Measurements and tests on FBK silicon sensors with an optimized electronic design for a CTA camera
Authors:
G. Ambrosi,
M. Ambrosio,
C. Aramo,
E. Bissaldi,
M. Capasso,
D. Corti,
A. de Angelis,
F. de Palma,
F. Ferrarotto,
A. Ferri,
S. Garrappa,
N. Giglietto,
F. Giordano,
A. Gola,
M. Ionica,
M. Iori,
F. Licciulli,
M. Mariotti,
C. Marzocca,
R. Paoletti,
C. Piemonte,
V. Postolache,
R. Rando,
C. Stella,
P. Vallania
, et al. (1 additional authors not shown)
Abstract:
In October 2013, the Italian Ministry approved the funding of a Research & Development (R&D) study, within the "Progetto Premiale TElescopi CHErenkov made in Italy (TECHE)", devoted to the development of a demonstrator for a camera for the Cherenkov Telescope Array (CTA) consortium. The demonstrator consists of a sensor plane based on the Silicon Photomultiplier (SiPM) technology and on an electro…
▽ More
In October 2013, the Italian Ministry approved the funding of a Research & Development (R&D) study, within the "Progetto Premiale TElescopi CHErenkov made in Italy (TECHE)", devoted to the development of a demonstrator for a camera for the Cherenkov Telescope Array (CTA) consortium. The demonstrator consists of a sensor plane based on the Silicon Photomultiplier (SiPM) technology and on an electronics designed for signal sampling. Preliminary tests on a matrix of sensors produced by the Fondazione Bruno Kessler (FBK-Trento, Italy) and on electronic prototypes produced by SITAEL S.p.A. will be presented. In particular, we used different designs of the electronics in order to optimize the output signals in terms of tail cancellation. This is crucial for applications where a high background is expected, as for the CTA experiment.
△ Less
Submitted 19 November, 2014;
originally announced November 2014.
-
Development of a Thermal Control System with Mechanically Pumped CO2 Two-Phase Loops for the AMS-02 Tracker on the ISS
Authors:
G. Alberti,
A. Alvino,
G. Ambrosi,
M. Bardet,
R. Battiston,
S. Borsini,
J. F. Cao,
Y. Chen,
J. van Es,
C. Gargiulo,
K. H. Guo,
L. Guo,
Z. H. He,
Z. C. Huang,
V. Koutsenko,
E. Laudi,
A. Lebedev,
S. C. Lee,
T. X. Li,
Y. L. Lin,
S. S. Lv,
M. Menichelli,
J. Y. Miao,
D. C. Mo,
J. Q. Ni
, et al. (15 additional authors not shown)
Abstract:
To provide a stable thermal environment for the AMS-Tracker, a thermal control system based on mechanically pumped CO2 two-phase loops was developed. It has been operating reliably in space since May 19, 2011. In this article, we summarize the design, construction, tests, and performance of the AMS-Tracker thermal control system (AMS-TTCS).
To provide a stable thermal environment for the AMS-Tracker, a thermal control system based on mechanically pumped CO2 two-phase loops was developed. It has been operating reliably in space since May 19, 2011. In this article, we summarize the design, construction, tests, and performance of the AMS-Tracker thermal control system (AMS-TTCS).
△ Less
Submitted 18 February, 2013;
originally announced February 2013.
-
Silicon photomultiplier arrays - a novel photon detector for a high resolution tracker produced at FBK-irst, Italy
Authors:
R. Greim,
H. Gast,
T. Kirn,
J. Olzem,
G. Roper Yearwood,
S. Schael,
N. Zimmermann,
G. Ambrosi,
P. Azzarello,
R. Battiston,
C. Piemonte
Abstract:
A silicon photomultiplier (SiPM) array has been developed at FBK-irst having 32 channels and a dimension of 8.0 x 1.1 mm^2. Each 250 um wide channel is subdivided into 5 x 22 rectangularly arranged pixels. These sensors are developed to read out a modular high resolution scintillating fiber tracker. Key properties like breakdown voltage, gain and photon detection efficiency (PDE) are found to be…
▽ More
A silicon photomultiplier (SiPM) array has been developed at FBK-irst having 32 channels and a dimension of 8.0 x 1.1 mm^2. Each 250 um wide channel is subdivided into 5 x 22 rectangularly arranged pixels. These sensors are developed to read out a modular high resolution scintillating fiber tracker. Key properties like breakdown voltage, gain and photon detection efficiency (PDE) are found to be homogeneous over all 32 channels of an SiPM array. This could make scintillating fiber trackers with SiPM array readout a promising alternative to available tracker technologies, if noise properties and the PDE are improved.
△ Less
Submitted 23 March, 2009;
originally announced March 2009.
-
A Scintillating Fiber Tracker With SiPM Readout
Authors:
G. Roper Yearwood,
B. Beischer,
Ch. -H. Chung,
Ph. v. Doetinchem,
H. Gast,
R. Greim,
T. Kirn,
S. Schael,
N. Zimmermann,
T. Nakada,
G. Ambrosi,
P. Azzarello,
R. Battiston,
C. Piemonte
Abstract:
We present a prototype for the first tracking detector consisting of 250 micron thin scintillating fibers and silicon photomultiplier (SiPM) arrays. The detector has a modular design, each module consists of a mechanical support structure of 10mm Rohacell foam between two 100 micron thin carbon fiber skins. Five layers of scintillating fibers are glued to both top and bottom of the support struc…
▽ More
We present a prototype for the first tracking detector consisting of 250 micron thin scintillating fibers and silicon photomultiplier (SiPM) arrays. The detector has a modular design, each module consists of a mechanical support structure of 10mm Rohacell foam between two 100 micron thin carbon fiber skins. Five layers of scintillating fibers are glued to both top and bottom of the support structure. SiPM arrays with a channel pitch of 250 micron are placed in front of the fibers. We show the results of the first module prototype using multiclad fibers of types Bicron BCF-20 and Kuraray SCSF-81M that were read out by novel 32-channel SiPM arrays from FBK-irst/INFN Perugia as well as 32-channel SiPM arrays produced by Hamamatsu. A spatial resolution of 88 micron +/- 6 micron at an average yield of 10 detected photons per minimal ionizig particle has been achieved.
△ Less
Submitted 2 December, 2008;
originally announced December 2008.