Characterisation of a low-momentum high-rate muon beam monitor for the FAMU experiment at the CNAO-XPR beam facility
Authors:
Riccardo Rossini,
Roberto Benocci,
Roberto Bertoni,
Maurizio Bonesini,
Stefano Carsi,
Massimiliano Clemenza,
Antonio de Bari,
Marco Donetti,
Carlo de Vecchi,
Alessandro Menegolli,
Alessio Mereghetti,
Emiliano Mocchiutti,
Christian Petroselli,
Marco Cesare Prata,
Marco Pullia,
Gian Luca Raselli,
Massimo Rossella,
Simone Savazzi,
Ludovico Tortora,
Erik Silvio Vallazza
Abstract:
The FAMU experiment aims at an indirect measurement of the Zemach radius of the proton. The measurement is carried out on muonic hydrogen atoms produced through the low-momentum (50-60 MeV/c) muon beam a the RIKEN-RAL negative muon facility. The particle flux plays an important role in this measurement, as it is proportional to the number of muonic hydrogen atoms produced, which is the target of t…
▽ More
The FAMU experiment aims at an indirect measurement of the Zemach radius of the proton. The measurement is carried out on muonic hydrogen atoms produced through the low-momentum (50-60 MeV/c) muon beam a the RIKEN-RAL negative muon facility. The particle flux plays an important role in this measurement, as it is proportional to the number of muonic hydrogen atoms produced, which is the target of the FAMU experimental method. The beam monitor calibration technique and results, presented here, are meant to extract a reliable estimation of the muon flux during the FAMU data taking. These measurements were carried out at the CNAO synchrotron in Pavia, Italy, using proton beams and supported by Monte Carlo simulation of the detector in Geant4.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy
Authors:
Alfredo Mirandola,
S. Molinelli,
G. Vilches Freixas,
M. Donetti,
A. Mairani,
E. Gallio,
D. Panizza,
S. Russo,
G. Magro,
S. Giordanengo,
M. Ciocca,
R. Orecchia
Abstract:
Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadrontherapy. Methods: The laterally integrated depth-dose-distributions (IDDs) were acquired with the PTW Peakfinder, a variable depth water column, equipped with two Bragg peak ionization chambers. FLUKA MC code was used…
▽ More
Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadrontherapy. Methods: The laterally integrated depth-dose-distributions (IDDs) were acquired with the PTW Peakfinder, a variable depth water column, equipped with two Bragg peak ionization chambers. FLUKA MC code was used to generate the energy libraries, the IDDs in water, and the fragment spectra for carbon beams. EBT3 films were used for spot size measurements, beam position over the scan field, and homogeneity in 2D-fields. Beam monitor calibration was performed in terms of number of particles per MU using both a Farmer-type and an Advanced Markus ionization chamber. The beam position at the isocenter, beam monitor calibration curve, dose constancy in the center of the spread-out-Bragg-peak, dose homogeneity in 2D-fields, beam energy, spot size, and spot position over the scan field are all checked on a daily basis for both protons and carbon ions and on all beam lines. Results: The simulated IDDs showed an excellent agreement with the measured experimental curves. The measured FWHM of the pencil beam in air at the isocenter was from 0.7 to 2.2 cm for protons. For carbon ions, two sets of spot size are available: from 0.4 to 0.8 cm (for the smaller) and from 0.8 to 1.1 cm (for the larger one). The spot position was within +/-1 mm over the whole 20x20 cm2 scan field; homogeneity in a uniform squared field was within +/-5% for both particle types at any energy. QA results exceeding tolerance levels were rarely found. In the reporting period, the machine downtime was around 6%, of which 4.5% was due to planned maintenance shutdowns. Conclusions: After successful dosimetric beam commissioning, quality assurance measurements performed during a 24-month period show very stable beam characteristics.
△ Less
Submitted 14 May, 2022;
originally announced May 2022.
-
The CNAO Dose Delivery System for modulated scanning ion beam radiotherapy
Authors:
Simona Giordanengo,
Maria Adelaide Garella,
Flavio Marchetto,
Faiza Bourhaleb,
Mario Ciocca,
Alfredo Mirandola,
Vincenzo Monaco,
Mohammad Amin Hosseini,
Cristian Peroni,
Roberto Sacchi,
Roberto Cirio,
Marco Donetti
Abstract:
This paper describes the dose delivery system used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. CNAO Foundation, INFN and University of Torino have developed and commissioned a Dose Delivery System (DDS) to monitor and guide ion beams accelerated by a synchrotron and to distribute the dose with a 3D scanning technique. The target volume, se…
▽ More
This paper describes the dose delivery system used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. CNAO Foundation, INFN and University of Torino have developed and commissioned a Dose Delivery System (DDS) to monitor and guide ion beams accelerated by a synchrotron and to distribute the dose with a 3D scanning technique. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. At CNAO, these operations are performed by the DDS. The main components of this system are 2 independent beam monitoring detectors (BOX1 and BOX2), interfaced with 2 control systems performing real-time control, and connected to the scanning magnets and the beam chopper. As a reaction to any potential hazard, a DDS interlock signal is sent to the Patient Interlock System which immediately stops the irradiation. The tasks and operations performed by the DDS are described following the data flow from the Treatment Planning System through the end of the treatment delivery. The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by 3 years of system activity. The DDS described in this paper is one among the few worldwide existing systems to operate ion beam for modulated scanning radiotherapy. It has proven to guide and control the therapeutic pencil beams with accuracy and stability showing dose deviations lower than the acceptance threshold of 5% and 2.5% respectively during daily Quality Assurance measurements.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
The FragmentatiOn Of Target Experiment (FOOT) and its DAQ system
Authors:
Silvia Biondi,
Andrey Alexandrov,
Behcet Alpat,
Giovanni Ambrosi,
Stefano Argirò,
Rau Arteche Diaz,
Nazarm Bartosik,
Giuseppe Battistoni,
Nicola Belcari,
Elettra Bellinzona,
Maria Giuseppina Bisogni,
Graziano Bruni,
Pietro Carra,
Piergiorgio Cerello,
Esther Ciarrocchi,
Alberto Clozza,
Sofia Colombi,
Giovanni De Lellis,
Alberto Del Guerra,
Micol De Simoni,
Antonia Di Crescenzo,
Benedetto Di Ruzza,
Marco Donetti,
Yunsheng Dong,
Marco Durante
, et al. (70 additional authors not shown)
Abstract:
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experim…
▽ More
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experiment has been developed in such a way that the experimental setup is easily movable and fits the space limitations of the experimental and treatment rooms available in hadrontherapy treatment centers, where most of the data takings are carried out. The Trigger and Data Acquisition system needs to follow the same criteria and it should work in different laboratories and in different conditions. It has been designed to acquire the largest sample size with high accuracy in a controlled and online-monitored environment. The data collected are processed in real-time for quality assessment and are available to the DAQ crew and detector experts during data taking.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
A new detector for the beam energy measurement in proton therapy: a feasibility study
Authors:
A. Vignati,
S. Giordanengo,
F. Mas Milian,
Z. Ahmadi Ganjeh,
M. Donetti,
F. Fausti,
M. Ferrero,
O. Hammad Ali,
O. A. Martì Villarreal,
G. Mazza,
Z. Shakarami,
V. Sola,
A. Staiano,
R. Cirio,
R. Sacchi,
V. Monaco,
.
Abstract:
Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy could allow assessing the range of penetration during treatments, encouraging the development of new dose delivery techniques for moving targets. Towards this e…
▽ More
Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy could allow assessing the range of penetration during treatments, encouraging the development of new dose delivery techniques for moving targets. Towards this end, the proof of concept of a new device, able to measure in a few seconds the energy of clinical proton beams (from 60 to 230 MeV) from the Time of Flight (ToF) of protons, is presented. The prototype consists of two Ultra Fast Silicon Detector (UFSD) pads, featuring an active thickness of 80 um and a sensitive area of 3 x 3 mm2, aligned along the beam direction in a telescope configuration, connected to a broadband amplifier and readout by a digitizer. Measurements were performed at the Centro Nazionale di Adroterapia Oncologica (CNAO, Pavia, Italy), at five different clinical beam energies and four distances between the sensors (from 7 to 97 cm) for each energy. In order to derive the beam energy from the measured average ToF, several systematic effects were considered, Monte Carlo simulations were developed to validate the method and a global fit approach was adopted to calibrate the system. The results were benchmarked against the energy values obtained from the water equivalent depths provided by CNAO. Deviations of few hundreds of keV have been achieved for all considered proton beam energies for both 67 and 97 cm distances between the sensors and few seconds of irradiation were necessary to collect the required statistics. These preliminary results indicate that a telescope of UFSDs could achieve in a few seconds the accuracy required for the clinical application and therefore encourage further investigations towards the improvement and the optimization of the present prototype.
△ Less
Submitted 19 March, 2020;
originally announced March 2020.
-
Dose Delivery Concept and Instrumentation
Authors:
Simona Giordanengo,
Marco Donetti
Abstract:
Radiation therapy aims to deliver the prescribed amount of dose to a tumour at the same time as sparing the surrounding tissues as much as possible. In charged particle therapy, delivering the prescribed dose is equivalent to delivering the prescribed number of ions of a given energy at each position of the irradiation field. The accurate delivery is committed to a dose delivery (DD) system that s…
▽ More
Radiation therapy aims to deliver the prescribed amount of dose to a tumour at the same time as sparing the surrounding tissues as much as possible. In charged particle therapy, delivering the prescribed dose is equivalent to delivering the prescribed number of ions of a given energy at each position of the irradiation field. The accurate delivery is committed to a dose delivery (DD) system that shapes, guides and controls the beam before the patient entrance. Most of the early DD systems provided uniform lateral dose profiles by using different devices, mainly patient-specific, placed in the beam line to shape the three-dimensional final target dose. More recently, systems that provide highly conformal dose distributions using thousands of narrow beams at well-defined energy were developed which feature advanced scanning magnets and real-time beam monitors, without patient-specific hardware. This lecture will cover the general dose delivery concept as well as the different DD instrumentations depending mainly on the beam delivery technique and on the particle and accelerator types. Some characteristic worldwide DD and beam monitor systems will be mentioned.
△ Less
Submitted 14 February, 2018;
originally announced March 2018.