The FragmentatiOn Of Target Experiment (FOOT) and its DAQ system
Authors:
Silvia Biondi,
Andrey Alexandrov,
Behcet Alpat,
Giovanni Ambrosi,
Stefano Argirò,
Rau Arteche Diaz,
Nazarm Bartosik,
Giuseppe Battistoni,
Nicola Belcari,
Elettra Bellinzona,
Maria Giuseppina Bisogni,
Graziano Bruni,
Pietro Carra,
Piergiorgio Cerello,
Esther Ciarrocchi,
Alberto Clozza,
Sofia Colombi,
Giovanni De Lellis,
Alberto Del Guerra,
Micol De Simoni,
Antonia Di Crescenzo,
Benedetto Di Ruzza,
Marco Donetti,
Yunsheng Dong,
Marco Durante
, et al. (70 additional authors not shown)
Abstract:
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experim…
▽ More
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experiment has been developed in such a way that the experimental setup is easily movable and fits the space limitations of the experimental and treatment rooms available in hadrontherapy treatment centers, where most of the data takings are carried out. The Trigger and Data Acquisition system needs to follow the same criteria and it should work in different laboratories and in different conditions. It has been designed to acquire the largest sample size with high accuracy in a controlled and online-monitored environment. The data collected are processed in real-time for quality assessment and are available to the DAQ crew and detector experts during data taking.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
Analysis of time-profiles with in-beam PET monitoring in charged particle therapy
Authors:
A. C. Kraan,
S. Muraro,
G. Battistoni,
N. Belcari,
M. G. Bisogni,
N. Camarlinghi,
A. Del Guerra,
A. Ferrari,
R. Kopec,
D. Krzempek,
M. Morrocchi,
P. Olko,
P. Sala,
K. Skowronska,
G. Sportelli,
A. Topi,
V. Rosso
Abstract:
Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability…
▽ More
Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability of MC predictions of space and time (decay rate) profiles shortly after irradiation, and we show how the decay rates can give an indication about the elements of which the phantom is made up.
Methods and Materials: Various phantoms were irradiated in clinical and near-clinical conditions at the Cyclotron Centre of the Bronowice proton therapy centre. PET data were acquired with a planar 16x16 cm$^2$ PET system. MC simulations of particle interactions and photon propagation in the phantoms were performed using the FLUKA code. The analysis included a comparison between experimental data and MC simulations of space and time profiles, as well as a fitting procedure to obtain the various isotope contributions in the phantoms.
Results and conclusions: There was a good agreement between data and MC predictions in 1-dimensional space and decay rate distributions. The fractions of $^{11}$C, $^{15}$O and $^{10}$C that were obtained by fitting the decay rates with multiple simple exponentials generally agreed well with the MC expectations. We found a small excess of $^{10}$C in data compared to what was predicted in MC, which was clear especially in the PE phantom.
△ Less
Submitted 28 September, 2018;
originally announced September 2018.
-
First tests for an online treatment monitoring system with in-beam PET for proton therapy
Authors:
Aafke C. Kraan,
G. Battistoni,
N. Belcari,
N. Camarlinghi,
F. Cappucci,
M. Ciocca,
A. Ferrari,
S. Ferretti,
A. Mairani,
S. Molinelli,
M. Pullia,
A. Retico,
P. Sala,
G. Sportelli,
A. Del Guerra,
V. Rosso
Abstract:
PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements for proton range verification in phantoms, performed at the CNAO particle therapy treatment center in Pavia, Italy, with our 10 x 10 cm^2 planar PET prototype Do…
▽ More
PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements for proton range verification in phantoms, performed at the CNAO particle therapy treatment center in Pavia, Italy, with our 10 x 10 cm^2 planar PET prototype DoPET. PMMA phantoms were irradiated with mono-energetic proton beams and clinical treatment plans, and PET data were acquired during and shortly after proton irradiation. We created 1-D profiles of the beta+ activity along the proton beam-axis, and evaluated the difference between the proximal rise and the distal fall-off position of the activity distribution. A good agreement with FLUKA Monte Carlo predictions was obtained. We also assessed the system response when the PMMA phantom contained an air cavity. The system was able to detect these cavities quickly after irradiation.
△ Less
Submitted 26 November, 2014;
originally announced November 2014.