The Liquid Argon In A Testbeam (LArIAT) Experiment
Authors:
LArIAT Collaboration,
R. Acciarri,
C. J. Adams,
J. Asaadi,
M. Backfish,
W. Badgett,
B. Baller,
O. Benevides Rodrigues,
F. d. M. Blaszczyk,
R. Bouabid,
C. Bromberg,
R. Carey,
R. Castillo Fernandez,
F. Cavanna,
J. I. Cevallos Aleman,
A. Chatterjee,
P. Dedin Neto,
M. V. Dos Santos,
S. Dytman,
D. Edmunds,
M. Elkins,
C. O. Escobar,
J. Esquivel,
J. Evans,
A. Falcone
, et al. (81 additional authors not shown)
Abstract:
The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.
The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.
△ Less
Submitted 6 February, 2020; v1 submitted 23 November, 2019;
originally announced November 2019.
-
Beam Tests of Beampipe Coatings for Electron Cloud Mitigation in Fermilab Main Injector
Authors:
Michael Backfish,
Jeffrey Eldred,
Cheng Yang Tan,
Robert Zwaska
Abstract:
Electron cloud beam instabilities are an important consideration in virtually all high-energy particle accelerators and could pose a formidable challenge to forthcoming high-intensity accelerator upgrades. Dedicated tests have shown beampipe coatings dramatically reduce the density of electron cloud in particle accelerators. In this work, we evaluate the performance of titanium nitride, amorphous…
▽ More
Electron cloud beam instabilities are an important consideration in virtually all high-energy particle accelerators and could pose a formidable challenge to forthcoming high-intensity accelerator upgrades. Dedicated tests have shown beampipe coatings dramatically reduce the density of electron cloud in particle accelerators. In this work, we evaluate the performance of titanium nitride, amorphous carbon, and diamond-like carbon as beampipe coatings for the mitigation of electron cloud in the Fermilab Main Injector. Altogether our tests represent 2700 ampere-hours of proton operation spanning five years. Three electron cloud detectors, retarding field analyzers, are installed in a straight section and allow a direct comparison between the electron flux in the coated and uncoated stainless steel beampipe. We characterize the electron flux as a function of intensity up to a maximum of 50 trillion protons per cycle. Each beampipe material conditions in response to electron bombardment from the electron cloud and we track the changes in these materials as a function of time and the number of absorbed electrons. Contamination from an unexpected vacuum leak revealed a potential vulnerability in the amorphous carbon beampipe coating. We measure the energy spectrum of electrons incident on the stainless steel, titanium nitride and amorphous carbon beampipes. We find the electron cloud signal is highly sensitive to stray magnetic fields and bunch-length over the Main Injector ramp cycle. We conduct a complete survey of the stray magnetic fields at the test station and compare the electron cloud signal to that in a field-free region.
△ Less
Submitted 26 July, 2015;
originally announced July 2015.
-
LArIAT: Liquid Argon In A Testbeam
Authors:
J. Paley,
D. Gastler,
E. Kearns,
R. Linehan,
R. Patterson,
W. Foremen,
J. Ho,
D. Schmitz,
R. Johnson,
J. St. John,
R. Acciarri,
P. Adamson,
M. Backfish,
W. Badgett,
B. Baller,
A. Hahn,
D. Jensen,
T. Junk,
M. Kirby,
T. Kobilarcik,
P. Kryczynski,
H. Lippincott,
A. Marchionni,
K. Nishikawa,
J. Raaf
, et al. (42 additional authors not shown)
Abstract:
Liquid Argon Time Projection Chambers (LArTPCs) are ideal detectors for precision neutrino physics. These detectors, when located deep underground, can also be used for measurements of proton decay, and astrophysical neutrinos. The technology must be completely developed, up to very large mass scales, and fully mastered to construct and operate these detectors for this physics program. As part of…
▽ More
Liquid Argon Time Projection Chambers (LArTPCs) are ideal detectors for precision neutrino physics. These detectors, when located deep underground, can also be used for measurements of proton decay, and astrophysical neutrinos. The technology must be completely developed, up to very large mass scales, and fully mastered to construct and operate these detectors for this physics program. As part of an integrated plan of developing these detectors, accurate measurements in LArTPC of known particle species in the relevant energy ranges are now deemed as necessary. The LArIAT program aims to directly achieve these goals by deploying LArTPC detectors in a dedicated calibration test beam line at Fermilab. The set of measurements envisaged here are significant for both the short-baseline (SBN) and long-baseline (LBN) neutrino oscillation programs in the US, starting with MicroBooNE in the near term and with the adjoint near and far liquid argon detectors in the Booster beam line at Fermilab envisioned in the mid-term, and moving towards deep underground physics such as with the long-baseline neutrino facility (LBNF) in the longer term.
△ Less
Submitted 27 June, 2014; v1 submitted 20 June, 2014;
originally announced June 2014.