-
DUNE Phase II: Scientific Opportunities, Detector Concepts, Technological Solutions
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1347 additional authors not shown)
Abstract:
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I…
▽ More
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I and Phase II, as did the European Strategy for Particle Physics. While the construction of the DUNE Phase I is well underway, this White Paper focuses on DUNE Phase II planning. DUNE Phase-II consists of a third and fourth far detector (FD) module, an upgraded near detector complex, and an enhanced 2.1 MW beam. The fourth FD module is conceived as a "Module of Opportunity", aimed at expanding the physics opportunities, in addition to supporting the core DUNE science program, with more advanced technologies. This document highlights the increased science opportunities offered by the DUNE Phase II near and far detectors, including long-baseline neutrino oscillation physics, neutrino astrophysics, and physics beyond the standard model. It describes the DUNE Phase II near and far detector technologies and detector design concepts that are currently under consideration. A summary of key R&D goals and prototyping phases needed to realize the Phase II detector technical designs is also provided. DUNE's Phase II detectors, along with the increased beam power, will complete the full scope of DUNE, enabling a multi-decadal program of groundbreaking science with neutrinos.
△ Less
Submitted 22 August, 2024;
originally announced August 2024.
-
First Measurement of the Total Inelastic Cross-Section of Positively-Charged Kaons on Argon at Energies Between 5.0 and 7.5 GeV
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1341 additional authors not shown)
Abstract:
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/$c$ beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each…
▽ More
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/$c$ beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380$\pm$26 mbarns for the 6 GeV/$c$ setting and 379$\pm$35 mbarns for the 7 GeV/$c$ setting.
△ Less
Submitted 1 August, 2024;
originally announced August 2024.
-
Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber
Authors:
ICARUS collaboration,
P. Abratenko,
N. Abrego-Martinez,
A. Aduszkiewic,
F. Akbar,
L. Aliaga Soplin,
M. Artero Pons,
J. Asaadi,
W. F. Badgett,
B. Baibussinov,
B. Behera,
V. Bellini,
R. Benocci,
J. Berger,
S. Berkman,
S. Bertolucci,
M. Betancourt,
M. Bonesini,
T. Boone,
B. Bottino,
A. Braggiotti,
D. Brailsford,
S. J. Brice,
V. Brio,
C. Brizzolari
, et al. (156 additional authors not shown)
Abstract:
This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are us…
▽ More
This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are used for the calorimetric energy scale calibration of the ICARUS TPC, which is also presented. The impact of the EMB model is studied on calorimetric particle identification, as well as muon and proton energy measurements. Accounting for the angular dependence in EMB recombination improves the accuracy and precision of these measurements.
△ Less
Submitted 9 August, 2024; v1 submitted 17 July, 2024;
originally announced July 2024.
-
Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber
Authors:
ICARUS collaboration,
P. Abratenko,
N. Abrego-Martinez,
A. Aduszkiewic,
F. Akbar,
L. Aliaga Soplin,
M. Artero Pons,
J. Asaadi,
W. F. Badgett,
B. Baibussinov,
B. Behera,
V. Bellini,
R. Benocci,
J. Berger,
S. Berkman,
S. Bertolucci,
M. Betancourt,
M. Bonesini,
T. Boone,
B. Bottino,
A. Braggiotti,
D. Brailsford,
S. J. Brice,
V. Brio,
C. Brizzolari
, et al. (156 additional authors not shown)
Abstract:
The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedu…
▽ More
The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.
△ Less
Submitted 5 August, 2024; v1 submitted 16 July, 2024;
originally announced July 2024.
-
Supernova Pointing Capabilities of DUNE
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electr…
▽ More
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on $^{40}$Ar and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called ``brems flipping'', as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE's burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage.
△ Less
Submitted 14 July, 2024;
originally announced July 2024.
-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Doping Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1297 additional authors not shown)
Abstract:
Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 2 August, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Front-end Electronics and Optimal Ganging Schemes for Single Photon Detection with Large Arrays of SiPMs in Liquid Argon
Authors:
P. Carniti,
E. Cristaldo,
A. Falcone,
C. Gotti,
G. Pessina,
F. Terranova
Abstract:
The operation of large arrays of silicon photomultipliers (SiPM) in tanks of noble liquids requires low noise, low power front-end amplifiers, able to operate reliably in the cryogenic environment. A suitable amplifier needs to be paired with a proper SiPM ganging scheme, meaning the series/parallel combination of SiPMs at its input. This paper presents a simple model to estimate the ganging schem…
▽ More
The operation of large arrays of silicon photomultipliers (SiPM) in tanks of noble liquids requires low noise, low power front-end amplifiers, able to operate reliably in the cryogenic environment. A suitable amplifier needs to be paired with a proper SiPM ganging scheme, meaning the series/parallel combination of SiPMs at its input. This paper presents a simple model to estimate the ganging scheme that gives the best signal to noise ratio once the basic electrical characteristics of the SiPM and amplifier are known. To prove the validity of the model, we used an amplifier based on discrete components, which achieves a white voltage noise in the 0.25-0.37 nV/$\surd$Hz range at liquid nitrogen temperature, while drawing 2-5 mW of power. Combined with the optimal ganging scheme obtained with the model, the amplifier demonstrated excellent single photon sensitivity up to 96 6x6 mm$^2$ SiPMs (total area 34.6 cm$^2$, S/N $\simeq$ 8-11). The measured results are in a good match with calculated values, predicting the possibility to achieve a clear separation of photoelectron peaks also with larger areas.
△ Less
Submitted 6 October, 2023;
originally announced October 2023.
-
Design and performance of the ENUBET monitored neutrino beam
Authors:
F. Acerbi,
I. Angelis,
L. Bomben,
M. Bonesini,
F. Bramati,
A. Branca,
C. Brizzolari,
G. Brunetti,
M. Calviani,
S. Capelli,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
N. Charitonidis,
F. Cindolo,
G. Cogo,
G. Collazuol,
F. Dal Corso,
C. Delogu,
G. De Rosa,
A. Falcone,
B. Goddard,
A. Gola,
D. Guffanti,
L. Halić
, et al. (47 additional authors not shown)
Abstract:
The ENUBET project is aimed at designing and experimentally demonstrating the concept of monitored neutrino beams. These novel beams are enhanced by an instrumented decay tunnel, whose detectors reconstruct large-angle charged leptons produced in the tunnel and give a direct estimate of the neutrino flux at the source. These facilities are thus the ideal tool for high-precision neutrino cross-sect…
▽ More
The ENUBET project is aimed at designing and experimentally demonstrating the concept of monitored neutrino beams. These novel beams are enhanced by an instrumented decay tunnel, whose detectors reconstruct large-angle charged leptons produced in the tunnel and give a direct estimate of the neutrino flux at the source. These facilities are thus the ideal tool for high-precision neutrino cross-section measurements at the GeV scale because they offer superior control of beam systematics with respect to existing facilities. In this paper, we present the first end-to-end design of a monitored neutrino beam capable of monitoring lepton production at the single particle level. This goal is achieved by a new focusing system without magnetic horns, a 20 m normal-conducting transfer line for charge and momentum selection, and a 40 m tunnel instrumented with cost-effective particle detectors. Employing such a design, we show that percent precision in cross-section measurements can be achieved at the CERN SPS complex with existing neutrino detectors.
△ Less
Submitted 18 August, 2023;
originally announced August 2023.
-
Highly-parallelized simulation of a pixelated LArTPC on a GPU
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1282 additional authors not shown)
Abstract:
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we pr…
▽ More
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on $10^3$ pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype.
△ Less
Submitted 28 February, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1235 additional authors not shown)
Abstract:
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is…
▽ More
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.
△ Less
Submitted 31 May, 2023; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Cryogenic front-end amplifier design for large SiPM arrays in the DUNE FD1-HD photon detection system
Authors:
C. Brizzolari,
P. Carniti,
C. Cattadori,
E. Cristaldo,
A. de la Torre Rojo,
M. Delgado,
A. Falcone,
K. Francis,
N. Gallice,
C. Gotti,
M. Guarise,
E. Montagna,
A. Montanari,
G. Pessina,
M. Pozzato,
J. Smolik,
F. Terranova,
L. Tomassetti,
A. Verdugo de Osa,
D. Warner,
J. Zalesak,
A. Zani,
J. Zuklin,
V. Zutshi
Abstract:
The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of choice are silicon photomultipliers (SiPM), 6$\times$6 mm$^2$ each, arranged in groups of 48, which present a significantly low impedance to the front-end electronic…
▽ More
The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of choice are silicon photomultipliers (SiPM), 6$\times$6 mm$^2$ each, arranged in groups of 48, which present a significantly low impedance to the front-end electronics. This paper details the design of a cryogenic amplifier with exceptionally low white voltage noise of 0.37 nV$\sqrt{Hz}$, based on a silicon-germanium input transistor and a BiCMOS fully differential operational amplifier. It yields excellent single photoelectron resolution even at low overvoltage values. The signal rise time is below 100 ns, and the dynamic range is about 2000 photoelectrons at the typical operating overvoltage. It draws 0.7 mA from a single 3.3 V supply, for a power consumption of 2.4 mW per channel. Simplified models were developed to predict the single photolectron signal shape and the signal to noise ratio, with a good match to measured performance.
△ Less
Submitted 14 November, 2022; v1 submitted 27 July, 2022;
originally announced July 2022.
-
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1203 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a char…
▽ More
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.
△ Less
Submitted 17 July, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1204 additional authors not shown)
Abstract:
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det…
▽ More
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.
△ Less
Submitted 30 June, 2022; v1 submitted 31 March, 2022;
originally announced March 2022.
-
Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1202 additional authors not shown)
Abstract:
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and…
▽ More
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties
△ Less
Submitted 3 June, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Low-Energy Physics in Neutrino LArTPCs
Authors:
D. Caratelli,
W. Foreman,
A. Friedland,
S. Gardiner,
I. Gil-Botella,
G. Karagiorgi,
M. Kirby,
G. Lehmann Miotto,
B. R. Littlejohn,
M. Mooney,
J. Reichenbacher,
A. Sousa,
K. Scholberg,
J. Yu,
T. Yang,
S. Andringa,
J. Asaadi,
T. J. C. Bezerra,
F. Capozzi,
F. Cavanna,
E. Church,
A. Himmel,
T. Junk,
J. Klein,
I. Lepetic
, et al. (264 additional authors not shown)
Abstract:
In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below…
▽ More
In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. 2) Low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. 3) BSM signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of BSM scenarios accessible in LArTPC-based searches. 4) Neutrino interaction cross sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood. Improved theory and experimental measurements are needed. Pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for experimentally improving this understanding. 5) There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. 6) Novel ideas for future LArTPC technology that enhance low-energy capabilities should be explored. These include novel charge enhancement and readout systems, enhanced photon detection, low radioactivity argon, and xenon doping. 7) Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways.
△ Less
Submitted 1 March, 2022;
originally announced March 2022.
-
Measuring the Quantum Efficiency of X-Ray Hybrid CMOS Detectors
Authors:
Joseph M. Colosimo,
Abraham D. Falcone,
Mitchell Wages,
Samuel V. Hull,
David N. Burrows,
Mitchell Range,
Fredric Hancock,
Cole R. Armstrong,
Gooderham McCormick,
Daniel M. LaRocca
Abstract:
Next-generation X-ray observatories, such as the Lynx X-ray Observatory Mission Concept, will require detectors with high quantum efficiency (QE) across the soft X-ray band to observe the faint objects that drive their mission science cases. Hybrid CMOS Detectors (HCDs), a form of active-pixel sensor, are promising candidates for use on these missions because of their faster read-out, lower power…
▽ More
Next-generation X-ray observatories, such as the Lynx X-ray Observatory Mission Concept, will require detectors with high quantum efficiency (QE) across the soft X-ray band to observe the faint objects that drive their mission science cases. Hybrid CMOS Detectors (HCDs), a form of active-pixel sensor, are promising candidates for use on these missions because of their faster read-out, lower power consumption, and greater radiation hardness than detectors used in the current generation of X-ray telescopes. In this work, we present QE measurements of a Teledyne H2RG HCD. These measurements were performed using a gas-flow proportional counter as a reference detector to measure the absolute flux incident on the HCD. We find an effective QE of $95.0 \pm 1.1\%$ at the Mn K$α$/K$β$ lines (at 5.9 and 6.5 keV), $98.5 \pm 1.8\%$ at the Al K$α$ line (1.5 keV), and $85.0 \pm 2.8\%$ at the O K$α$ line (0.52 keV).
△ Less
Submitted 4 October, 2021;
originally announced October 2021.
-
Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1132 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on t…
▽ More
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3$σ$ (5$σ$) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3$σ$ level with a 100 kt-MW-yr exposure for the maximally CP-violating values $δ_{\rm CP}} = \pmπ/2$. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti,
M. P. Andrews
, et al. (1158 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA.…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of $7\times 6\times 7.2$~m$^3$. The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components.
△ Less
Submitted 23 September, 2021; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Coded masks for imaging of neutrino events
Authors:
M. Andreotti,
P. Bernardini,
A. Bersani,
S. Bertolucci,
S. Biagi,
A. Branca,
C. Brizzolari,
G. Brunetti,
I. Cagnoli,
R. Calabrese,
A. Caminata,
A. Campani,
P. Carniti,
R. Cataldo,
C. Cattadori,
S. Cherubini,
V. Cicero,
M. Citterio,
S. Copello,
P. Cova,
E. Cristaldo Morales,
S. Davini,
N. Delmonte,
G. De Matteis,
S. Di Domizio
, et al. (54 additional authors not shown)
Abstract:
The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity in order to reconstruct the path of ionizing particles. This preliminary study is based on the use of masks to encode the light signal combined with single-phot…
▽ More
The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity in order to reconstruct the path of ionizing particles. This preliminary study is based on the use of masks to encode the light signal combined with single-photon detectors. In this respect, the proposed system is able to detect tracks over focal distances of about tens of centimeters. From numerical simulations it emerges that it is possible to successfully decode and recognize signals, even complex, with a relatively limited number of acquisition channels. Such innovative technique can be very fruitful in a new generation of detectors devoted to neutrino physics and dark matter search. Indeed the introduction of coded masks combined with SiPM detectors is proposed for a liquid-Argon target in the Near Detector of the DUNE experiment.
△ Less
Submitted 21 November, 2021; v1 submitted 22 May, 2021;
originally announced May 2021.
-
Enhancement of the X-Arapuca photon detection device for the DUNE experiment
Authors:
C. Brizzolari,
S. Brovelli,
F. Bruni,
P. Carniti,
C. M. Cattadori,
A. Falcone,
C. Gotti,
A. Machado,
F. Meinardi,
G. Pessina,
E. Segreto,
H. V. Souza,
M. Spanu,
F. Terranova,
M. Torti
Abstract:
In the Deep Underground Neutrino Experiment (DUNE), the VUV LAr luminescence is collected by light trap devices named X-Arapuca, sizing (480x93) mm2. Six thousand of these units will be deployed in the first DUNE ten kiloton far detector module. In this work we present the first characterization of the photon detection efficiency of an X-Arapuca device sizing (200x75) mm2 via a complete and accura…
▽ More
In the Deep Underground Neutrino Experiment (DUNE), the VUV LAr luminescence is collected by light trap devices named X-Arapuca, sizing (480x93) mm2. Six thousand of these units will be deployed in the first DUNE ten kiloton far detector module. In this work we present the first characterization of the photon detection efficiency of an X-Arapuca device sizing (200x75) mm2 via a complete and accurate set of measurements along the cell longitudinal axis with a movable 241-Am source. The MPPCs photosensors are readout by a cryogenic transimpedance amplifier to enhance the single photoelectron sensitivity and improve the signal-to-noise while ganging 8 MPPC for a total surface of 288 mm2. Moreover we developed a new photon downshifting polymeric material, by which the X-Arapuca photon detection efficiency was enhanced of about +50% with respect to the baseline off-shell product deployed in the standard device configuration. The achieved results are compared to previous measurements on a half size X-Arapuca device, with a fixed source facing the center, with no cold amplification stage, and discussed in view of the DUNE full size optical cell construction for both the horizontal and the vertical drift configurations of the DUNE TPC design and in view of liquid Argon doping by ppms of Xe. Other particle physics projects adopting Liquid Argon as target or active veto, as Dark Side and LEGEND or the DUNE Near Detector will take advantage of this novel wavelength shifting material.
△ Less
Submitted 15 April, 2021;
originally announced April 2021.
-
Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report
Authors:
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
N. Anfimov,
A. Ankowski,
M. Antonova,
S. Antusch
, et al. (1041 additional authors not shown)
Abstract:
This report describes the conceptual design of the DUNE near detector
This report describes the conceptual design of the DUNE near detector
△ Less
Submitted 25 March, 2021;
originally announced March 2021.
-
Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
Authors:
B. Aimard,
L. Aizawa,
C. Alt,
J. Asaadi,
M. Auger,
V. Aushev,
D. Autiero,
A. Balaceanu,
G. Balik,
L. Balleyguier,
E. Bechetoille,
D. Belver,
A. M. Blebea-Apostu,
S. Bolognesi,
S. Bordoni,
N. Bourgeois,
B. Bourguille,
J. Bremer,
G. Brown,
G. Brunetti,
L. Brunetti,
D. Caiulo,
M. Calin,
E. Calvo,
M. Campanelli
, et al. (138 additional authors not shown)
Abstract:
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passi…
▽ More
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.
△ Less
Submitted 20 December, 2020; v1 submitted 16 October, 2020;
originally announced October 2020.
-
Overhaul and Installation of the ICARUS-T600 Liquid Argon TPC Electronics for the FNAL Short Baseline Neutrino Program
Authors:
L. Bagby,
B. Baibussinov,
B. Behera,
V. Bellini,
R. Benocci,
M. Betancourt,
M. Bettini,
M. Bonesini,
T. Boone,
A. Braggiotti,
J. D. Brown,
H. Budd,
F. Calaon,
L. Castellani,
S. Centro,
A. G. Cocco,
M. Convery,
F. Fabris,
A. Falcone,
C. Farnese,
A. Fava,
F. Fichera,
M. Giarin,
D. Gibin,
A. Guglielmi
, et al. (39 additional authors not shown)
Abstract:
The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016-2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme…
▽ More
The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016-2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme are described. The design of a new signal feed-through flange is also a fundamental piece of this overhaul whose major feature is the integration of all electronics components onto the signal flange. Initial functionality tests of the full TPC electronics chain installed in the T600 detector at FNAL are also described.
△ Less
Submitted 25 November, 2020; v1 submitted 5 October, 2020;
originally announced October 2020.
-
Supernova Neutrino Burst Detection with the Deep Underground Neutrino Experiment
Authors:
DUNE collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (949 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE), a 40-kton underground liquid argon time projection chamber experiment, will be sensitive to the electron-neutrino flavor component of the burst of neutrinos expected from the next Galactic core-collapse supernova. Such an observation will bring unique insight into the astrophysics of core collapse as well as into the properties of neutrinos. The gen…
▽ More
The Deep Underground Neutrino Experiment (DUNE), a 40-kton underground liquid argon time projection chamber experiment, will be sensitive to the electron-neutrino flavor component of the burst of neutrinos expected from the next Galactic core-collapse supernova. Such an observation will bring unique insight into the astrophysics of core collapse as well as into the properties of neutrinos. The general capabilities of DUNE for neutrino detection in the relevant few- to few-tens-of-MeV neutrino energy range will be described. As an example, DUNE's ability to constrain the $ν_e$ spectral parameters of the neutrino burst will be considered.
△ Less
Submitted 29 May, 2021; v1 submitted 15 August, 2020;
originally announced August 2020.
-
First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform
Authors:
DUNE Collaboration,
B. Abi,
A. Abed Abud,
R. Acciarri,
M. A. Acero,
G. Adamov,
M. Adamowski,
D. Adams,
P. Adrien,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga
, et al. (970 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of $7.2\times 6.0\times 6.9$ m$^3$. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV$/c$ to 7 GeV/$c$. Beam line instrumentation provides accurate momentum measurements…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of $7.2\times 6.0\times 6.9$ m$^3$. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV$/c$ to 7 GeV/$c$. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, $dE/dx$ calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.
△ Less
Submitted 3 June, 2021; v1 submitted 13 July, 2020;
originally announced July 2020.
-
Neutrino interaction classification with a convolutional neural network in the DUNE far detector
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (951 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment is a next-generation neutrino oscillation experiment that aims to measure $CP$-violation in the neutrino sector as part of a wider physics program. A deep learning approach based on a convolutional neural network has been developed to provide highly efficient and pure selections of electron neutrino and muon neutrino charged-current interactions. The electr…
▽ More
The Deep Underground Neutrino Experiment is a next-generation neutrino oscillation experiment that aims to measure $CP$-violation in the neutrino sector as part of a wider physics program. A deep learning approach based on a convolutional neural network has been developed to provide highly efficient and pure selections of electron neutrino and muon neutrino charged-current interactions. The electron neutrino (antineutrino) selection efficiency peaks at 90% (94%) and exceeds 85% (90%) for reconstructed neutrino energies between 2-5 GeV. The muon neutrino (antineutrino) event selection is found to have a maximum efficiency of 96% (97%) and exceeds 90% (95%) efficiency for reconstructed neutrino energies above 2 GeV. When considering all electron neutrino and antineutrino interactions as signal, a selection purity of 90% is achieved. These event selections are critical to maximize the sensitivity of the experiment to $CP$-violating effects.
△ Less
Submitted 10 November, 2020; v1 submitted 26 June, 2020;
originally announced June 2020.
-
The ENUBET positron tagger prototype: construction and testbeam performance
Authors:
F. Acerbi,
M. Bonesini,
F. Bramati,
A. Branca,
C. Brizzolari,
G. Brunetti,
S. Capelli,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
C. Delogu,
G. De Rosa,
A. Falcone,
A. Gola,
C. Jollet,
B. Klicek,
Y. Kudenko,
M. Laveder,
A. Longhin,
L. Ludovici,
E. Lutsenko
, et al. (28 additional authors not shown)
Abstract:
A prototype for the instrumented decay tunnel of ENUBET was tested in 2018 at the CERN East Area facility with charged particles up to 5 GeV. This detector is a longitudinal sampling calorimeter with lateral scintillation light readout. The calorimeter was equipped by an additional "$t_0$-layer" for timing and photon discrimination. The performance of this detector in terms of electron energy reso…
▽ More
A prototype for the instrumented decay tunnel of ENUBET was tested in 2018 at the CERN East Area facility with charged particles up to 5 GeV. This detector is a longitudinal sampling calorimeter with lateral scintillation light readout. The calorimeter was equipped by an additional "$t_0$-layer" for timing and photon discrimination. The performance of this detector in terms of electron energy resolution, linearity, response to muons and hadron showers are presented in this paper and compared with simulation. The $t_0$-layer was studied both in standalone mode using pion charge exchange and in combined mode with the calorimeter to assess the light yield and the 1 mip/2 mip separation capability. We demonstrate that this system fulfills the requirements for neutrino physics applications and discuss performance and additional improvements.
△ Less
Submitted 12 June, 2020;
originally announced June 2020.
-
Design and implementation of the new scintillation light detection system of ICARUS T600
Authors:
B. Ali-Mohammadzadeh,
M. Babicz,
W. Badgett,
L. Bagby,
V. Bellini,
R. Benocci,
M. Bonesini,
A. Braggiotti,
S. Centro,
A. Chatterjee,
A. G. Cocco,
M. Diwan,
A. Falcone,
C. Farnese,
A. Fava,
D. Gibin,
A. Guglielmi,
W. Ketchum,
U. Kose,
A. Menegolli,
G. Meng,
C. Montanari,
M. Nessi,
F. Pietropaolo,
A. Rappoldi
, et al. (15 additional authors not shown)
Abstract:
ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab(USA), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances.…
▽ More
ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab(USA), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementationof the new scintillation light detection system of ICARUS T600 is described.
△ Less
Submitted 1 September, 2020; v1 submitted 9 June, 2020;
originally announced June 2020.
-
The hadronic beamline of the ENUBET neutrino beam
Authors:
ENUBET collaboration,
C. Delogu,
F. Acerbi,
A. Berra,
M. Bonesini,
A. Branca,
C. Brizzolari,
G. Brunetti,
M. Calviani,
S. Capelli,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
N. Charitonidis,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
G. De Rosa,
A. Falcone,
A. Gola,
C. Jollet,
V. Kain,
B. Klicek,
Y. Kudenko
, et al. (35 additional authors not shown)
Abstract:
The ENUBET ERC project (2016-2021) is studying a facility based on a narrow band beam capable of constraining the neutrino fluxes normalization through the monitoring of the associated charged leptons in an instrumented decay tunnel. A key element of the project is the design and optimization of the hadronic beamline. In this proceeding we present progress on the studies of the proton extraction s…
▽ More
The ENUBET ERC project (2016-2021) is studying a facility based on a narrow band beam capable of constraining the neutrino fluxes normalization through the monitoring of the associated charged leptons in an instrumented decay tunnel. A key element of the project is the design and optimization of the hadronic beamline. In this proceeding we present progress on the studies of the proton extraction schemes. We also show a realistic implementation and simulation of the beamline.
△ Less
Submitted 26 November, 2020; v1 submitted 7 April, 2020;
originally announced April 2020.
-
Decay tunnel instrumentation for the ENUBET neutrino beam
Authors:
F. Acerbi,
A. Berra,
M. Bonesini,
A. Branca,
C. Brizzolari,
G. Brunetti,
M. Calviani,
S. Capelli,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
N. Charitonidis,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
C. Delogu,
G. De Rosa,
A. Falcone,
A. Gola,
C. Jollet,
V. Kain,
B. Klicek,
Y. Kudenko,
M. Laveder
, et al. (34 additional authors not shown)
Abstract:
The uncertainty in the initial neutrino flux is the main limitation for a precise determination of the absolute neutrino cross section. The ERC funded ENUBET project (2016-2021) is studying a facility based on a narrow band beam to produce an intense source of electron neutrinos with a ten-fold improvement in accuracy. Since March 2019 ENUBET is also a Neutrino Platform experiment at CERN: NP06/EN…
▽ More
The uncertainty in the initial neutrino flux is the main limitation for a precise determination of the absolute neutrino cross section. The ERC funded ENUBET project (2016-2021) is studying a facility based on a narrow band beam to produce an intense source of electron neutrinos with a ten-fold improvement in accuracy. Since March 2019 ENUBET is also a Neutrino Platform experiment at CERN: NP06/ENUBET. A key element of the project is the instrumentation of the decay tunnel to monitor large angle positrons produced together with $ν_e$ in the three body decays of kaons ($K_{e3}$) and to discriminate them from neutral and charged pions. The need for an efficient and high purity e/$π$ separation over a length of several meters, and the requirements for fast response and radiation hardness imposed by the harsh beam environment, suggested the implementation of a longitudinally segmented Fe/scintillator calorimeter with a readout based on WLS fibers and SiPM detectors. An extensive experimental program through several test beam campaigns at the CERN-PS T9 beam line has been pursued on calorimeter prototypes, both with a shashlik and a lateral readout configuration. The latter, in which fibers collect the light from the side of the scintillator tiles, allows to place the light sensors away from the core of the calorimeter, thus reducing possible irradiation damages with respect to the shashlik design. This contribution will present the achievements of the prototyping activities carried out, together with irradiation tests made on the Silicon Photo-Multipliers. The results achieved so far pin down the technology of choice for the construction of the 3 m long demonstrator that will take data in 2021.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
The laser diode calibration system of the ICARUS T600 detector at FNAL
Authors:
M. Bonesini,
R. Benocci,
R. Bertoni,
A. Falcone,
R. Mazza,
M. Torti,
A. Menegolli,
G. L. Raselli,
M. Rossella
Abstract:
The ICARUS T600 LAr TPC is the far detector of the Short Baseline Program at FNAL. As it will have to work at shallow depth in the Booster Neutrino Beam, a large cosmic rays background ($\sim 11$ kHz) will be present. To reduce it, precise timing information is needed from the new light detection system, based on 360 large area photomultipliers. For precise time measurements a calibration system b…
▽ More
The ICARUS T600 LAr TPC is the far detector of the Short Baseline Program at FNAL. As it will have to work at shallow depth in the Booster Neutrino Beam, a large cosmic rays background ($\sim 11$ kHz) will be present. To reduce it, precise timing information is needed from the new light detection system, based on 360 large area photomultipliers. For precise time measurements a calibration system based on a fast laser diode and a system based on one optical switch, several $1 \times 10$ fused fiber splitters, ultra-high vacuum optical feedthroughs and multimode optical patchcords up to 20 m long, to distribute the laser pulses to each single PMT, was designed. The time evolution of the PMTs' gain/timing and possibly their initial calibrations at a time $t_0$ will be done by using this system. The expected time resolution of this calibration system will be around 100 ps. The laboratory tests needed to set up the system are reported.
△ Less
Submitted 28 March, 2020;
originally announced March 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume IV: Far Detector Single-phase Technology
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-clas…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
Central to achieving DUNE's physics program is a far detector that combines the many tens-of-kiloton fiducial mass necessary for rare event searches with sub-centimeter spatial resolution in its ability to image those events, allowing identification of the physics signatures among the numerous backgrounds. In the single-phase liquid argon time-projection chamber (LArTPC) technology, ionization charges drift horizontally in the liquid argon under the influence of an electric field towards a vertical anode, where they are read out with fine granularity. A photon detection system supplements the TPC, directly enhancing physics capabilities for all three DUNE physics drivers and opening up prospects for further physics explorations.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume IV presents an overview of the basic operating principles of a single-phase LArTPC, followed by a description of the DUNE implementation. Each of the subsystems is described in detail, connecting the high-level design requirements and decisions to the overriding physics goals of DUNE.
△ Less
Submitted 8 September, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume III: DUNE Far Detector Technical Coordination
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Exper…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed.
This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module.
△ Less
Submitted 8 September, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume II: DUNE Physics
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-clas…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume II of this TDR, DUNE Physics, describes the array of identified scientific opportunities and key goals. Crucially, we also report our best current understanding of the capability of DUNE to realize these goals, along with the detailed arguments and investigations on which this understanding is based.
This TDR volume documents the scientific basis underlying the conception and design of the LBNF/DUNE experimental configurations. As a result, the description of DUNE's experimental capabilities constitutes the bulk of the document. Key linkages between requirements for successful execution of the physics program and primary specifications of the experimental configurations are drawn and summarized.
This document also serves a wider purpose as a statement on the scientific potential of DUNE as a central component within a global program of frontier theoretical and experimental particle physics research. Thus, the presentation also aims to serve as a resource for the particle physics community at large.
△ Less
Submitted 25 March, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume I: Introduction to DUNE
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Exper…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. This TDR is intended to justify the technical choices for the far detector that flow down from the high-level physics goals through requirements at all levels of the Project. Volume I contains an executive summary that introduces the DUNE science program, the far detector and the strategy for its modular designs, and the organization and management of the Project. The remainder of Volume I provides more detail on the science program that drives the choice of detector technologies and on the technologies themselves. It also introduces the designs for the DUNE near detector and the DUNE computing model, for which DUNE is planning design reports.
Volume II of this TDR describes DUNE's physics program in detail. Volume III describes the technical coordination required for the far detector design, construction, installation, and integration, and its organizational structure. Volume IV describes the single-phase far detector technology. A planned Volume V will describe the dual-phase technology.
△ Less
Submitted 8 September, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Cryogenic SiPM arrays for the DUNE photon detection system
Authors:
A. Falcone,
A. Andreani,
S. Bertolucci,
C. Brizzolari,
N. Buckanamd,
M. Capasso,
C. Cattadori,
P. Carniti,
M. Citterio,
K. Francis,
N. Gallice,
A. Gola,
C. Gotti,
I. Lax,
P. Litrico,
A. Mazzi,
M. Mellinato,
A. Montanari,
L. Patrizii,
L. Pasqualini,
G. Pessina,
M. Pozzato,
S. Riboldi,
P. Sala,
G. Sirri
, et al. (7 additional authors not shown)
Abstract:
In this paper we report on the characterization of SiPM tiles developed for the R & D on the DUNE Photon Detection System. The tiles were produced by Fondazione Bruno Kessler (FBK) employing NUV-HD-SF SiPMs. Special emphasis is given on cryo-reliability of the sensors, i.e. the stability of electric and mechanical properties after thermal cycles at room and 77K temperature. The characterization in…
▽ More
In this paper we report on the characterization of SiPM tiles developed for the R & D on the DUNE Photon Detection System. The tiles were produced by Fondazione Bruno Kessler (FBK) employing NUV-HD-SF SiPMs. Special emphasis is given on cryo-reliability of the sensors, i.e. the stability of electric and mechanical properties after thermal cycles at room and 77K temperature. The characterization includes the determination of the I-V curve, a high sensitivity measurement of Dark Count Rate at different overvoltages, and correlated noise. The single p.e. sensitivity is measured as a function of the number of sensors connected to a single electronic channel, after amplification at 77K using a dedicated cold amplifier.
△ Less
Submitted 24 January, 2020;
originally announced January 2020.
-
Study of space charge in the ICARUS T600 detector
Authors:
M. Antonello,
B. Baibussinov,
V. Bellini,
F. Boffelli,
M. Bonesini,
A. Bubak,
S. Centro,
K. Cieslik,
A. G. Cocco,
A. Dabrowska,
A. Dermenev,
A. Falcone,
C. Farnese,
A. Fava,
A. Ferrari,
D. Gibin,
S. Gninenko,
A. Guglielmi,
M. Haranczyk,
J. Holeczek,
M. Kirsanov,
J. Kisiel,
I. Kochanek,
J. Lagoda,
A. Menegolli
, et al. (23 additional authors not shown)
Abstract:
The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays.…
▽ More
The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. A detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.
△ Less
Submitted 28 May, 2020; v1 submitted 24 January, 2020;
originally announced January 2020.
-
Polysiloxane-based scintillators for shashlik calorimeters
Authors:
F. Acerbi,
A. Branca,
C. Brizzolari,
G. Brunetti,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
F. Dal Corso,
G. De Rosa,
C. Delogu,
A. Falcone,
A. Gola,
C. Jollet,
B. Kliček,
Y. Kudenko,
M. Laveder,
A. Longhin,
L. Ludovici,
E. Lutsenko,
L. Magaletti,
G. Mandrioli,
T. Marchi,
A. Margotti
, et al. (24 additional authors not shown)
Abstract:
We present the first application of polysiloxane-based scintillators as active medium in a shashlik sampling calorimeter. These results were obtained from a testbeam campaign of a $\sim$6$\times$6$\times$45 cm$^3$ (13 $X_0$ depth) prototype. A Wavelength Shifting fiber array of 36 elements runs perpendicularly to the stack of iron (15 mm) and polysiloxane scintillator (15 mm) tiles with a density…
▽ More
We present the first application of polysiloxane-based scintillators as active medium in a shashlik sampling calorimeter. These results were obtained from a testbeam campaign of a $\sim$6$\times$6$\times$45 cm$^3$ (13 $X_0$ depth) prototype. A Wavelength Shifting fiber array of 36 elements runs perpendicularly to the stack of iron (15 mm) and polysiloxane scintillator (15 mm) tiles with a density of about one over cm$^2$. Unlike shashlik calorimeters based on plastic organic scintillators, here fibers are optically matched with the scintillator without any intermediate air gap. The prototype features a compact light readout based on Silicon Photo-Multipliers embedded in the bulk of the detector. The detector was tested with electrons, pions and muons with energies ranging from 1 to 7 GeV at the CERN-PS. This solution offers a highly radiation hard detector to instrument the decay region of a neutrino beam, providing an event-by-event measurement of high-angle decay products associated with neutrino production (ENUBET, Enhanced NeUtrino BEams from kaon Tagging, ERC project). The results in terms of light yield, uniformity and energy resolution, are compared to a similar calorimeter built with ordinary plastic scintillators.
△ Less
Submitted 9 January, 2020;
originally announced January 2020.
-
The Liquid Argon In A Testbeam (LArIAT) Experiment
Authors:
LArIAT Collaboration,
R. Acciarri,
C. J. Adams,
J. Asaadi,
M. Backfish,
W. Badgett,
B. Baller,
O. Benevides Rodrigues,
F. d. M. Blaszczyk,
R. Bouabid,
C. Bromberg,
R. Carey,
R. Castillo Fernandez,
F. Cavanna,
J. I. Cevallos Aleman,
A. Chatterjee,
P. Dedin Neto,
M. V. Dos Santos,
S. Dytman,
D. Edmunds,
M. Elkins,
C. O. Escobar,
J. Esquivel,
J. Evans,
A. Falcone
, et al. (81 additional authors not shown)
Abstract:
The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.
The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.
△ Less
Submitted 6 February, 2020; v1 submitted 23 November, 2019;
originally announced November 2019.
-
A low noise and low power cryogenic amplifier for single photoelectron sensitivity with large arrays of SiPMs
Authors:
P. Carniti,
A. Falcone,
C. Gotti,
A. Lucchini,
G. Pessina,
S. Riboldi,
F. Terranova
Abstract:
This paper presents a low noise amplifier for large arrays of silicon photomultipliers (SiPMs) operated in cryogenic environments, especially liquid argon (87 K) and liquid nitrogen (77 K). The goal is for one amplifier to read out a total photosensitive surface of tens of cm$^2$ while retaining the capability to resolve single photoelectron signals. Due to the large capacitance of SiPMs, typicall…
▽ More
This paper presents a low noise amplifier for large arrays of silicon photomultipliers (SiPMs) operated in cryogenic environments, especially liquid argon (87 K) and liquid nitrogen (77 K). The goal is for one amplifier to read out a total photosensitive surface of tens of cm$^2$ while retaining the capability to resolve single photoelectron signals. Due to the large capacitance of SiPMs, typically a few nF per cm$^2$, the main contributor to noise is the series (voltage) component. A silicon-germanium heterojunction bipolar transistor (HBT) was selected as the input device of the cryogenic amplifier, followed by a fully differential operational amplifier, operated in an unconventional feedback configuration. The input referred voltage noise of the circuit at 77 K is just below 0.4 nV/$\surd$Hz white (above 100 kHz) and 1 nV/$\surd$Hz at 10 kHz. The value of the base spreading resistance of the HBT at 77 K was determined from noise measurements at different bias currents. Power consumption of the full circuit is about 2.5 mW. The design gives the flexibility to optimally compensate the feedback loop for different values of the input capacitance, and obtain a gain-bandwidth product in the GHz range. The signal-to-noise ratio obtained in reading out SiPMs is discussed for the case of a 300 kHz low pass filter and compared with the upper limit that would derive from applying optimum filtering algorithms.
△ Less
Submitted 14 January, 2020; v1 submitted 15 November, 2019;
originally announced November 2019.
-
Calorimetry for low-energy electrons using charge and light in liquid argon
Authors:
W. Foreman,
R. Acciarri,
J. A. Asaadi,
W. Badgett,
F. d. M. Blaszczyk,
R. Bouabid,
C. Bromberg,
R. Carey,
F. Cavanna,
J. I. Cevallos Aleman,
A. Chatterjee,
J. Evans,
A. Falcone,
W. Flanagan,
B. T. Fleming,
D. Garcia-Gomez,
B. Gelli,
T. Ghosh,
R. A. Gomes,
E. Gramellini,
R. Gran,
P. Hamilton,
C. Hill,
J. Ho,
J. Hugon
, et al. (38 additional authors not shown)
Abstract:
Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-…
▽ More
Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stopping cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT's well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of $σ/E \simeq 9.3\%/\sqrt{E} \oplus 1.3\%$ is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N $\simeq$ 30, for example, the energy resolution for electrons below 40 MeV is improved by $\approx$ 10%, $\approx$ 20%, and $\approx$ 40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.
△ Less
Submitted 22 January, 2020; v1 submitted 17 September, 2019;
originally announced September 2019.
-
The ENUBET narrow band neutrino beam
Authors:
ENUBET Collaboration,
M. Tenti,
F. Acerbi,
G. Ballerini,
M. Bonesini,
C. Brizzolari,
G. Brunetti M. Calviani,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
E. Conti F. Dal Corso,
G. De Rosa,
C. Delogu,
A. Falcone,
B. Goddard,
A. Gola,
R. A. Intonti,
C. Jollet,
V. Kain,
B. Klicek,
Y. Kudenko,
M. Laveder,
A. Longhin
, et al. (32 additional authors not shown)
Abstract:
The narrow band beam of ENUBET is the first implementation of the "monitored neutrino beam" technique proposed in 2015. ENUBET has been designed to monitor lepton production in the decay tunnel of neutrino beams and to provide a 1% measurement of the neutrino flux at source. In particular, the three body semi-leptonic decay of kaons monitored by large angle positron production offers a fully contr…
▽ More
The narrow band beam of ENUBET is the first implementation of the "monitored neutrino beam" technique proposed in 2015. ENUBET has been designed to monitor lepton production in the decay tunnel of neutrino beams and to provide a 1% measurement of the neutrino flux at source. In particular, the three body semi-leptonic decay of kaons monitored by large angle positron production offers a fully controlled $ν_{e}$ source at the GeV scale for a new generation of short baseline experiments. In this contribution the performances of the positron tagger prototypes tested at CERN beamlines in 2016-2018 are presented.
△ Less
Submitted 27 March, 2019;
originally announced March 2019.
-
The ENUBET Beamline
Authors:
ENUBET Collaboration,
G. Brunetti,
F. Acerbi,
G. Ballerini,
M. Bonesini,
A. Branca,
C. Brizzolari,
M. Calviani,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
G. De Rosa,
C. Delogu,
A. Falcone,
B. Goddard,
A. Gola,
R. A. Intonti,
C. Jollet,
V. Kain,
B. Klicek,
Y. Kudenko
, et al. (34 additional authors not shown)
Abstract:
The ENUBET ERC project (2016-2021) is studying a narrow band neutrino beam where lepton production can be monitored at single particle level in an instrumented decay tunnel. This would allow to measure $ν_μ$ and $ν_{e}$ cross sections with a precision improved by about one order of magnitude compared to present results. In this proceeding we describe a first realistic design of the hadron beamline…
▽ More
The ENUBET ERC project (2016-2021) is studying a narrow band neutrino beam where lepton production can be monitored at single particle level in an instrumented decay tunnel. This would allow to measure $ν_μ$ and $ν_{e}$ cross sections with a precision improved by about one order of magnitude compared to present results. In this proceeding we describe a first realistic design of the hadron beamline based on a dipole coupled to a pair of quadrupole triplets along with the optimisation guidelines and the results of a simulation based on G4beamline. A static focusing design, though less efficient than a horn-based solution, results several times more efficient than originally expected. It works with slow proton extractions reducing drastically pile-up effects in the decay tunnel and it paves the way towards a time-tagged neutrino beam. On the other hand a horn-based transferline would ensure higher yields at the tunnel entrance. The first studies conducted at CERN to implement the synchronization between a few ms proton extraction and a horn pulse of 2-10 ms are also described.
△ Less
Submitted 26 November, 2020; v1 submitted 21 March, 2019;
originally announced March 2019.
-
A high precision neutrino beam for a new generation of short baseline experiments
Authors:
F. Acerbi,
G. Ballerini,
S. Bolognesi,
M. Bonesini,
C. Brizzolari,
G. Brunetti,
S. Carturan,
M. G. Catanesi,
S. Cecchini,
F. Cindolo,
G. Collazuol,
E. Conti,
F. Dal Corso,
G. De Rosa,
F. Di Lodovico,
C. Delogu,
A. Falcone,
A. Gola,
R. A. Intonti,
C. Jollet,
B. Klicek,
Y. Kudenko,
M. Laveder,
A. Longhin,
L. Ludovici
, et al. (31 additional authors not shown)
Abstract:
The current generation of short baseline neutrino experiments is approaching intrinsic source limitations in the knowledge of flux, initial neutrino energy and flavor. A dedicated facility based on conventional accelerator techniques and existing infrastructures designed to overcome these impediments would have a remarkable impact on the entire field of neutrino oscillation physics. It would impro…
▽ More
The current generation of short baseline neutrino experiments is approaching intrinsic source limitations in the knowledge of flux, initial neutrino energy and flavor. A dedicated facility based on conventional accelerator techniques and existing infrastructures designed to overcome these impediments would have a remarkable impact on the entire field of neutrino oscillation physics. It would improve by about one order of magnitude the precision on $ν_μ$ and $ν_e$ cross sections, enable the study of electroweak nuclear physics at the GeV scale with unprecedented resolution and advance searches for physics beyond the three-neutrino paradigm. In turn, these results would enhance the physics reach of the next generation long baseline experiments (DUNE and Hyper-Kamiokande) on CP violation and their sensitivity to new physics. In this document, we present the physics case and technology challenge of high precision neutrino beams based on the results achieved by the ENUBET Collaboration in 2016-2018. We also set the R&D milestones to enable the construction and running of this new generation of experiments well before the start of the DUNE and Hyper-Kamiokande data taking. We discuss the implementation of this new facility at three different level of complexity: $ν_μ$ narrow band beams, $ν_e$ monitored beams and tagged neutrino beams. We also consider a site specific implementation based on the CERN-SPS proton driver providing a fully controlled neutrino source to the ProtoDUNE detectors at CERN.
△ Less
Submitted 15 January, 2019;
originally announced January 2019.
-
Conformal Gravity and the Radial Acceleration Relation
Authors:
James G. O'Brien,
Thomas L. Chiarelli,
Mark A. Falcone,
Muhannad H. AlQurashi
Abstract:
During the 2016 International Workshop on Astronomy and Relativistic Astrophysics (IWARA), the question was raised as to if conformal gravity could explain the timely result of McGaugh et. al. 2016 which showed a universal nature found in the centripetal accelerations of spiral galaxies. At the time of the conference, the McGaugh result was only published for two weeks. Since then, the result has…
▽ More
During the 2016 International Workshop on Astronomy and Relativistic Astrophysics (IWARA), the question was raised as to if conformal gravity could explain the timely result of McGaugh et. al. 2016 which showed a universal nature found in the centripetal accelerations of spiral galaxies. At the time of the conference, the McGaugh result was only published for two weeks. Since then, the result has become known as the Radial Acceleration Relation (RAR) and has been considered tantamount to a natural law. In this work, we summarize how conformal gravity can explain the Radial Acceleration Rule in a fashion consistent with the findings of the original authors without the need for dark matter.
△ Less
Submitted 18 December, 2018;
originally announced January 2019.
-
The DUNE Far Detector Interim Design Report, Volume 3: Dual-Phase Module
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 3 describes the dual-phase module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The DUNE Far Detector Interim Design Report Volume 1: Physics, Technology and Strategies
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 1 contains an executive summary that describes the general aims of this document. The remainder of this first volume provides a more detailed description of the DUNE physics program that drives the choice of detector technologies. It also includes concise outlines of two overarching systems that have not yet evolved to consortium structures: computing and calibration. Volumes 2 and 3 of this IDR describe, for the single-phase and dual-phase technologies, respectively, each detector module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The DUNE Far Detector Interim Design Report, Volume 2: Single-Phase Module
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 2 describes the single-phase module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.