Measurement of the deuteron beam polarization at internal target at Nuclotron for DSS experiment
Authors:
Ya. T. Skhomenko,
V. P. Ladygin,
Yu. V. Gurchin,
A. Yu. Isupov,
M. Janek,
J. -T. Karachuk,
A. N. Khrenov,
P. K. Kurilkin,
A. N. Livanov,
S. M. Piyadin,
S. G. Reznikov,
A. A. Terekhin,
A. V. Tishevsky,
A. V. Averyanov,
A. S. Belov,
E. V. Chernykh,
D. Enache,
V. V. Fimushkin,
D. O. Krivenkov
Abstract:
The current deuteron beam polarimetry at Nuclotron is provided by the Internal Target polarimeter based on the use of the asymmetry in dp- elastic scattering at large angles in the cms at 270 MeV. The upgraded deuteron beam polarimeter has been used obtain the vector and tensor polarization during 2016/2017 runs for the DSS experimental program. The polarimeter has been used also for tuning of the…
▽ More
The current deuteron beam polarimetry at Nuclotron is provided by the Internal Target polarimeter based on the use of the asymmetry in dp- elastic scattering at large angles in the cms at 270 MeV. The upgraded deuteron beam polarimeter has been used obtain the vector and tensor polarization during 2016/2017 runs for the DSS experimental program. The polarimeter has been used also for tuning of the polarized ion source parameters for 6 different spin modes.
△ Less
Submitted 9 November, 2017;
originally announced November 2017.
-
First results on the measurements of the proton beam polarization at internal target at Nuclotron
Authors:
V. P. Ladygin,
Yu. V. Gurchin,
A. Yu. Isupov,
M. Janek,
A. N. Khrenov,
P. K. Kurilkin,
A. N. Livanov,
S. M. Piyadin,
S. G. Reznikov,
Ya. T. Skhomenko,
A. A. Terekhin,
A. V. Tishevsky,
A. V. Averyanov,
S. N. Bazylev,
A. S. Belov,
A. V. Butenko,
E. V. Chernykh,
Yu. N. Filatov,
V. V. Fimushkin,
D. O. Krivenkov,
A. M. Kondratenko,
M. A. Kondratenko,
A. D. Kovalenko,
I. V. Slepnev,
V. M. Slepnev
, et al. (4 additional authors not shown)
Abstract:
The spin program at NICA using SPD and MPD requires high intensity polarized proton beam with high value of the beam polarization. First results on the measurements of the proton beam polarization performed at internal target at Nuclotron are reported. The polarization of the proton beam provided by new source of polarized ions has been measured at 500 MeV using quasielastic proton-proton scatteri…
▽ More
The spin program at NICA using SPD and MPD requires high intensity polarized proton beam with high value of the beam polarization. First results on the measurements of the proton beam polarization performed at internal target at Nuclotron are reported. The polarization of the proton beam provided by new source of polarized ions has been measured at 500 MeV using quasielastic proton-proton scattering and DSS setup at internal target. The obtained value of the vertical polarization of ~35 % is consistent with the calculations taking into account the current magnetic optics of the Nuclotron injection line.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.
-
Annihilation of low energy antiprotons in silicon
Authors:
S. Aghion,
O. Ahlén,
A. S. Belov,
G. Bonomi,
P. Bräunig,
J. Bremer,
R. S. Brusa,
G. Burghart,
L. Cabaret,
M. Caccia,
C. Canali,
R. Caravita,
F. Castelli,
G. Cerchiari,
S. Cialdi,
D. Comparat,
G. Consolati,
J. H. Derking,
S. Di Domizio,
L. Di Noto,
M. Doser,
A. Dudarev,
R. Ferragut,
A. Fontana,
P. Genova
, et al. (34 additional authors not shown)
Abstract:
The goal of the AE$\mathrm{\bar{g}}$IS experiment at the Antiproton Decelerator (AD) at CERN, is to measure directly the Earth's gravitational acceleration on antimatter. To achieve this goal, the AE$\mathrm{\bar{g}}$IS collaboration will produce a pulsed, cold (100 mK) antihydrogen beam with a velocity of a few 100 m/s and measure the magnitude of the vertical deflection of the beam from a straig…
▽ More
The goal of the AE$\mathrm{\bar{g}}$IS experiment at the Antiproton Decelerator (AD) at CERN, is to measure directly the Earth's gravitational acceleration on antimatter. To achieve this goal, the AE$\mathrm{\bar{g}}$IS collaboration will produce a pulsed, cold (100 mK) antihydrogen beam with a velocity of a few 100 m/s and measure the magnitude of the vertical deflection of the beam from a straight path. The final position of the falling antihydrogen will be detected by a position sensitive detector. This detector will consist of an active silicon part, where the annihilations take place, followed by an emulsion part. Together, they allow to achieve 1$%$ precision on the measurement of $\bar{g}$ with about 600 reconstructed and time tagged annihilations.
We present here, to the best of our knowledge, the first direct measurement of antiproton annihilation in a segmented silicon sensor, the first step towards designing a position sensitive silicon detector for the AE$\mathrm{\bar{g}}$IS experiment. We also present a first comparison with Monte Carlo simulations (GEANT4) for antiproton energies below 5 MeV
△ Less
Submitted 11 March, 2014; v1 submitted 20 November, 2013;
originally announced November 2013.
-
Prospects for measuring the gravitational free-fall of antihydrogen with emulsion detectors
Authors:
AEgIS Collaboration,
S. Aghion,
O. Ahlén,
C. Amsler,
A. Ariga,
T. Ariga,
A. S. Belov,
G. Bonomi,
P. Bräunig,
J. Bremer,
R. S. Brusa,
L. Cabaret,
C. Canali,
R. Caravita,
F. Castelli,
G. Cerchiari,
S. Cialdi,
D. Comparat,
G. Consolati,
J. H. Derking,
S. Di Domizio,
L. Di Noto,
M. Doser,
A. Dudarev,
A. Ereditato
, et al. (46 additional authors not shown)
Abstract:
The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. AEgIS will measure the free-fall of an antihydrogen beam traversing a moiré deflectometer. The goal is to determine the gravitational acceleration g for antihydrogen with an initial relative accuracy of 1% by using an emulsion detector combined with a silicon micro-strip detector to measure the…
▽ More
The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. AEgIS will measure the free-fall of an antihydrogen beam traversing a moiré deflectometer. The goal is to determine the gravitational acceleration g for antihydrogen with an initial relative accuracy of 1% by using an emulsion detector combined with a silicon micro-strip detector to measure the time of flight. Nuclear emulsions can measure the annihilation vertex of antihydrogen atoms with a precision of about 1 - 2 microns r.m.s. We present here results for emulsion detectors operated in vacuum using low energy antiprotons from the CERN antiproton decelerator. We compare with Monte Carlo simulations, and discuss the impact on the AEgIS project.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
-
Formation Of A Cold Antihydrogen Beam in AEGIS For Gravity Measurements
Authors:
G. Testera,
A. S. Belov,
G. Bonomi,
I. Boscolo,
N. Brambilla,
R. S. Brusa,
V. M. Byakov,
L. Cabaret,
C. Canali,
C. Carraro,
F. Castelli,
S. Cialdi,
M. de Combarieu,
D. Comparat,
G. Consolati,
N. Djourelov,
M. Doser,
G. Drobychev,
A. Dupasquier,
D. Fabris,
R. Ferragut,
G. Ferrari,
A. Fischer,
A. Fontana,
P. Forget
, et al. (40 additional authors not shown)
Abstract:
The formation of the antihydrogen beam in the AEGIS experiment through the use of inhomogeneous electric fields is discussed and simulation results including the geometry of the apparatus and realistic hypothesis about the antihydrogen initial conditions are shown. The resulting velocity distribution matches the requirements of the gravity experiment. In particular it is shown that the inhomogen…
▽ More
The formation of the antihydrogen beam in the AEGIS experiment through the use of inhomogeneous electric fields is discussed and simulation results including the geometry of the apparatus and realistic hypothesis about the antihydrogen initial conditions are shown. The resulting velocity distribution matches the requirements of the gravity experiment. In particular it is shown that the inhomogeneous electric fields provide radial cooling of the beam during the acceleration.
△ Less
Submitted 30 May, 2008;
originally announced May 2008.
-
Development of a high-efficiency pulsed slow positron beam for measurements with orthopositronium in vacuum
Authors:
N. Alberola,
T. Anthonioz,
A. Badertscher,
C. Bas,
A. S. Belov,
P. Crivelli,
S. N. Gninenko,
N. A. Golubev,
M. M. Kirsanov,
A. Rubbia,
D. Sillou
Abstract:
We have developed a high-efficiency pulsed slow positron beam for experiments with orthopositronium in vacuum. The new pulsing scheme is based on a double-gap coaxial buncher powered by an RF pulse of appropriate shape. The modulation of the positron velocity in the two gaps is used to adjust their time-of-flight to a target. This pulsing scheme allows to minimize non-linear aberrations in the b…
▽ More
We have developed a high-efficiency pulsed slow positron beam for experiments with orthopositronium in vacuum. The new pulsing scheme is based on a double-gap coaxial buncher powered by an RF pulse of appropriate shape. The modulation of the positron velocity in the two gaps is used to adjust their time-of-flight to a target. This pulsing scheme allows to minimize non-linear aberrations in the bunching process and to efficiently compress positron pulses with an initial pulse duration ranging from 300 to 50 ns into bunches of 2.3 to 0.4 ns width, respectively, with a repetition period of 1 mks. The compression ratio achieved is ~100, which is a factor 5 better than has been previously obtained with slow positron beams based on a single buncher. Requirements on the degree, to which the moderated positrons should be mono-energetic and on the precision of the waveform generation are presented. Possible applications of the new pulsed positron beam for measurements of thin films are discussed.
△ Less
Submitted 7 November, 2005;
originally announced November 2005.