Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–8 of 8 results for author: Chiodi, G

Searching in archive physics. Search in all archives.
.
  1. arXiv:1703.09843  [pdf

    physics.ins-det astro-ph.IM physics.ed-ph physics.soc-ph

    An educational distributed Cosmic Ray detector network based on ArduSiPM

    Authors: V Bocci, G Chiodi, P Fresch, F Iacoangeli, L Recchia

    Abstract: The advent of microcontrollers with enough CPU power and with analog and digital peripherals makes possible to design a complete particle detector with relative acquisition system around one microcontroller chip. The existence of a world wide data infrastructure as internet allows for devising a distributed network of cheap detectors capable to elaborate and send data or respond to settings comman… ▽ More

    Submitted 28 March, 2017; originally announced March 2017.

  2. arXiv:1608.08364  [pdf, other

    physics.ins-det physics.med-ph

    First Ex-Vivo Validation of a Radioguided Surgery Technique with beta- Radiation

    Authors: E. Solfaroli Camillocci, M. Schiariti, V. Bocci, A. Carollo, G. Chiodi, M. Colandrea, F. Collamati, M. Cremonesi, R. Donnarumma, M. E. Ferrari, P. Ferroli, F. Ghielmetti, C. M. Grana, M. Marafini, S. Morganti, C. Mancini Terracciano, M. Patanè, G. Pedroli, B. Pollo, L. Recchia, A. Russomando, M. Toppi, G. Traini, R. Faccini

    Abstract: Purpose: A radio-guided surgery technique with beta- -emitting radio-tracers was suggested to overcome the effect of the large penetration of gamma radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an… ▽ More

    Submitted 30 August, 2016; originally announced August 2016.

    Comments: 17 pages, 4 Figs, Accepted by Physica Medica

    Journal ref: Phys. Med. 32(9) 1139 (2016)

  3. arXiv:1511.02059  [pdf, other

    physics.med-ph physics.ins-det

    An Intraoperative $β^-$ Detecting Probe For Radio-Guided Surgery in Tumour Resection

    Authors: Andrea Russomando, Fabio Bellini, Valerio Bocci, Giacomo Chiodi, Francesco Collamati, Erika De Lucia, Raffaella Donnarumma, Riccardo Faccini, Carlo Mancini Terracciano, Michela Marafini, Riccardo Paramatti, Vincenzo Patera, %Davide Pinci, Luigi Recchia, Alessio Sarti, Adalberto Sciubba, Elena Solfaroli Camillocci, Cecilia Voena, Silvio Morganti

    Abstract: The development of the $β^-$ based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To vali… ▽ More

    Submitted 6 November, 2015; originally announced November 2015.

    Comments: 7 pages, 15 figures

  4. arXiv:1506.01915  [pdf

    physics.ins-det

    A low cost network of spectrometer radiation detectors based on the ArduSiPM a compact transportable Software/Hardware Data Acquisition system with Arduino DUE

    Authors: Valerio Bocci, Giacomo Chiodi, Francesco Iacoangeli, Massimo Nuccetelli, Luigi Recchia

    Abstract: The necessity to use Photo Multipliers (PM) as light detector limited in the past the use of crystals in radiation handled device preferring the Geiger approach. The Silicon Photomultipliers (SiPMs) are very small and cheap, solid photon detectors with good dynamic range and single photon detection capability, they are usable to supersede in some application cumbersome and difficult to use Photo M… ▽ More

    Submitted 5 June, 2015; originally announced June 2015.

    Comments: arXiv admin note: text overlap with arXiv:1411.7814

  5. arXiv:1411.7814  [pdf

    physics.ins-det

    The ArduSiPM a compact trasportable Software/Hardware Data Acquisition system for SiPM detector

    Authors: Valerio Bocci, Giacomo Chiodi, Francesco Iacoangeli, Massimo Nuccetelli, Luigi Recchia

    Abstract: The acquisition of a single Silicon Photomultiplier require multiple and expensive electronics modules as : preamplifier, discriminator, bias voltage power supply, temperature monitor, Scalers, Analog to Digital Converter and Time to Digital Converter . The developed ArduSiPM is a compact cost effective and easily replicable Hardware software module for SiPM detector readout. The ArduSiPM uses an… ▽ More

    Submitted 28 November, 2014; originally announced November 2014.

  6. arXiv:1306.5655  [pdf, other

    physics.ins-det hep-ex

    SuperB Technical Design Report

    Authors: SuperB Collaboration, M. Baszczyk, P. Dorosz, J. Kolodziej, W. Kucewicz, M. Sapor, A. Jeremie, E. Grauges Pous, G. E. Bruno, G. De Robertis, D. Diacono, G. Donvito, P. Fusco, F. Gargano, F. Giordano, F. Loddo, F. Loparco, G. P. Maggi, V. Manzari, M. N. Mazziotta, E. Nappi, A. Palano, B. Santeramo, I. Sgura, L. Silvestris , et al. (384 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch… ▽ More

    Submitted 24 June, 2013; originally announced June 2013.

    Comments: 495 pages

    Report number: INFN-13-01/PI, LAL 13-01, SLAC-R-1003

  7. arXiv:1207.4902  [pdf, other

    physics.ins-det hep-ex

    Dependence of the energy resolution of a scintillating crystal on the readout integration time

    Authors: V. Bocci, D. Chao, G. Chiodi, R. Faccini, F. Ferroni, R. Lunadei, G. Martellotti, G. Penso, D. Pinci, L. Recchia

    Abstract: The possibilty of performing high-rate calorimetry with a slow scintillator crystal is studied. In this experimental situation, to avoid pulse pile-up, it can be necessary to base the energy measurement on only a fraction of the emitted light, thus spoiling the energy resolution. This effect was experimentally studied with a BGO crystal and a photomultiplier followed by an integrator, by measuring… ▽ More

    Submitted 31 August, 2012; v1 submitted 20 July, 2012; originally announced July 2012.

  8. arXiv:1103.0128  [pdf, other

    physics.ins-det physics.comp-ph

    High-speed data transfer with FPGAs and QSFP+ modules

    Authors: R. Ammendola, A. Biagioni, G. Chiodi, O. Frezza, F. Lo Cicero, A. Lonardo, R. Lunadei, P. S. Paolucci, D. Rossetti, A. Salamon, G. Salina, F. Simula, L. Tosoratto, P. Vicini

    Abstract: We present test results and characterization of a data transmission system based on a last generation FPGA and a commercial QSFP+ (Quad Small Form Pluggable +) module. QSFP+ standard defines a hot-pluggable transceiver available in copper or optical cable assemblies for an aggregated bandwidth of up to 40 Gbps. We implemented a complete testbench based on a commercial development card mounting an… ▽ More

    Submitted 1 March, 2011; originally announced March 2011.

    Comments: 5 pages, 3 figures, Published on JINST Journal of Instrumentation proceedings of Topical Workshop on Electronics for Particle Physics 2010, 20-24 September 2010, Aachen, Germany(R Ammendola et al 2010 JINST 5 C12019)

    Journal ref: JINST 5:C12019,2010