Measurement of the cosmic ray flux by an ArduSiPM-based muon telescope in the framework of the Lab2Go project
Authors:
V. Agostini,
B. Arcese,
N. Ascani,
P. Astone,
V. Bocci,
S. Caperna,
F. Casaburo,
A. Cerica,
C. D'Auria,
G. De Bonis,
D. Deda,
F. Di Mauro,
A. Di Vico,
R. Faccini,
L. Frasca,
G. Galuppi,
G. Giovannetti,
F. Iacoangeli,
G. Ludovici,
L. Martone,
B. Marucci,
L. Mizzoni,
A. Moriconi,
G. Organtini,
F. Piacentini
, et al. (4 additional authors not shown)
Abstract:
Whitin Istituto Nazionale di Fisica Nucleare (INFN) outreach activities, the Lab2Go project is of great significance. Its goal is involving high school teachers and students in several laboratory activities, aiming at increasing the weight of experimental contents in teaching and learning. In this article we present the measurement, carried out in the framework of the Lab2Go project, of the cosmic…
▽ More
Whitin Istituto Nazionale di Fisica Nucleare (INFN) outreach activities, the Lab2Go project is of great significance. Its goal is involving high school teachers and students in several laboratory activities, aiming at increasing the weight of experimental contents in teaching and learning. In this article we present the measurement, carried out in the framework of the Lab2Go project, of the cosmic muon flux made by an ArduSiPM-based muon telescope.
△ Less
Submitted 27 February, 2023; v1 submitted 30 January, 2023;
originally announced January 2023.
-
Measurement of fundamental physical quantities in the framework of the Lab2Go project
Authors:
F. Casaburo,
N. Marcelli,
M. Sorbara,
M. Agostinelli,
P. Astone,
F. Baldassarre,
F. Brunori,
S. Crisci,
G. De Bonis,
X. De Lucia,
D. De Pedis,
G. De Valeri,
G. Di Sciascio,
R. Faccini,
J. Falato,
V. Fraietta,
C. Gatto,
S. Guadagnini,
V. Oliviero,
G. Organtini,
V. Passamonti,
F. Piacentini,
N. Ruggiero,
M. Salerno,
S. Sarti
, et al. (1 additional authors not shown)
Abstract:
To establish a closer contact between school and experimental sciences, Sapienza Università di Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project. Lab2Go has the goal of spreading laboratory practice among students and teachers in high schools. In this article, it is presented a measurement, carried out in the framework of the Lab2Go project, of the ratio hc/e wh…
▽ More
To establish a closer contact between school and experimental sciences, Sapienza Università di Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project. Lab2Go has the goal of spreading laboratory practice among students and teachers in high schools. In this article, it is presented a measurement, carried out in the framework of the Lab2Go project, of the ratio hc/e where h, c and e are respectively the Planck constant, the speed of light in the vacuum, and the electric charge.
△ Less
Submitted 28 July, 2022; v1 submitted 30 January, 2022;
originally announced January 2022.
-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
Studio di un urto anelastico: una proposta per le Scuole Secondarie di II grado nell'ambito del progetto "Lab2Go"
Authors:
Pia Astone,
Roberto Balaudo,
Fausto Casaburo,
Francesca Cavanna,
Giulia De Bonis,
Riccardo Faccini,
Davide Fallara,
Andrei Grigoruta,
Giovanni Organtini,
Francesco Piacentini,
Francesco Pennazio
Abstract:
When a free falling ping-pong ball collides on a horizontal surface, it loses kinetic energy. The ratio between the height reached by the ball after the collision and the initial height is called restitution coefficient. A method to measure it by using a home-made cathetometer was proposed during the Olimpiadi di Fisica 2018. In this paper we show how to measure it also by using the PhyPhox app an…
▽ More
When a free falling ping-pong ball collides on a horizontal surface, it loses kinetic energy. The ratio between the height reached by the ball after the collision and the initial height is called restitution coefficient. A method to measure it by using a home-made cathetometer was proposed during the Olimpiadi di Fisica 2018. In this paper we show how to measure it also by using the PhyPhox app and Arduino board.
△ Less
Submitted 14 December, 2021; v1 submitted 19 June, 2021;
originally announced June 2021.
-
Il progetto Lab2Go per la diffusione della pratica laboratoriale nelle Scuole Secondarie di II grado
Authors:
Mirco Andreotti,
Pia Astone,
Donatella Campana,
Antonella Cartoni,
Fausto Casaburo,
Francesca Cavanna,
Gianluigi Cibinetto,
Antonella Dalla Cort,
Giulia De Bonis,
Marta Della Seta,
Francesca Di Mauro,
Giuseppe Di Sciascio,
Riccardo Faccini,
Federica Favino,
Luca Iocchi,
Marcello Lissia,
Giulia Morganti,
Mauro Mancini,
Giovanni Organtini,
Francesco Pennazio,
Francesco Piacentini,
Alina Piras,
Maria Ragosta,
Lorenzo Roberti,
Anna Rita Rossi
, et al. (2 additional authors not shown)
Abstract:
Even if laboratory practice is essential for all scientific branches of knowledge, it is often neglected at High School, due to lack of time and/or resources. To establish a closer contact between school and experimental sciences, the University Sapienza of Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project, with the goal of spreading laboratory practice among st…
▽ More
Even if laboratory practice is essential for all scientific branches of knowledge, it is often neglected at High School, due to lack of time and/or resources. To establish a closer contact between school and experimental sciences, the University Sapienza of Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project, with the goal of spreading laboratory practice among students and teachers in high schools.
△ Less
Submitted 20 November, 2021; v1 submitted 15 June, 2021;
originally announced June 2021.
-
Preliminary results in using Deep Learning to emulate BLOB, a nuclear interaction model
Authors:
A. Ciardiello,
M. Asai,
B. Caccia,
G. A. P. Cirrone,
M. Colonna,
A. Dotti,
R. Faccini,
S. Giagu,
A. Messina,
P. Napolitani,
L. Pandola,
D. H. Wright,
C. Mancini-Terracciano
Abstract:
Purpose: A reliable model to simulate nuclear interactions is fundamental for Ion-therapy. We already showed how BLOB ("Boltzmann-Langevin One Body"), a model developed to simulate heavy ion interactions up to few hundreds of MeV/u, could simulate also $^{12}$C reactions in the same energy domain. However, its computation time is too long for any medical application. For this reason we present the…
▽ More
Purpose: A reliable model to simulate nuclear interactions is fundamental for Ion-therapy. We already showed how BLOB ("Boltzmann-Langevin One Body"), a model developed to simulate heavy ion interactions up to few hundreds of MeV/u, could simulate also $^{12}$C reactions in the same energy domain. However, its computation time is too long for any medical application. For this reason we present the possibility of emulating it with a Deep Learning algorithm. Methods: The BLOB final state is a Probability Density Function (PDF) of finding a nucleon in a position of the phase space. We discretised this PDF and trained a Variational Auto-Encoder (VAE) to reproduce such a discrete PDF. As a proof of concept, we developed and trained a VAE to emulate BLOB in simulating the interactions of $^{12}$C with $^{12}$C at 62 MeV/u. To have more control on the generation, we forced the VAE latent space to be organised with respect to the impact parameter ($b$) training a classifier of $b$ jointly with the VAE. Results: The distributions obtained from the VAE are similar to the input ones and the computation time needed to use the VAE as a generator is negligible. Conclusions: We show that it is possible to use a Deep Learning approach to emulate a model developed to simulate nuclear reactions in the energy range of interest for Ion-therapy. We foresee the implementation of the generation part in C++ and to interface it with the most used Monte Carlo toolkit: Geant4.
△ Less
Submitted 10 April, 2020;
originally announced April 2020.
-
First Results from CUORE: A Search for Lepton Number Violation via $0νββ$ Decay of $^{130}$Te
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
E. Andreotti,
C. Arnaboldi,
F. T. Avignone III,
O. Azzolini,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
D. Biare,
M. Biassoni,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Camacho,
A. Caminata
, et al. (140 additional authors not shown)
Abstract:
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure…
▽ More
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we find no evidence for neutrinoless double-beta decay. The median statistical sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic uncertainties, we place a lower limit on the decay half-life of $T^{0ν}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find $T^{0ν}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find $m_{ββ}<(110 - 520)$ meV, where the range reflects the nuclear matrix element estimates employed.
△ Less
Submitted 1 April, 2018; v1 submitted 22 October, 2017;
originally announced October 2017.
-
Feasibility of the $β^-$ Radio-Guided Surgery with a Variety of Radio-Nuclides of Interest to Nuclear Medicine
Authors:
Carlo Mancini-Terracciano,
Raffaella Donnarumma,
Gaia Bencivenga,
Valerio Bocci,
Antonella Cartoni,
Francesco Collamati,
Ilaria Fratoddi,
Alessandro Giordano,
Luca Indovina,
Michela Marafini,
Silvio Morganti,
Dante Rotili,
Andrea Russomando,
Teresa Scotognella,
Elena Solfaroli Camillocci,
Marco Toppi,
Giacomo Traini,
Iole Venditti,
Riccardo Faccini
Abstract:
The $β^-$ based radio-guided surgery overcomes the corresponding $γ$ technique in case the background from healthy tissues is relevant. It can be used only in case a radio-tracer marked with $^{90}$Y is available since the current probe prototype was optimized for the emission spectrum of this radio-nuclide. Here we study, with a set of laboratory tests and simulations, the prototype capability in…
▽ More
The $β^-$ based radio-guided surgery overcomes the corresponding $γ$ technique in case the background from healthy tissues is relevant. It can be used only in case a radio-tracer marked with $^{90}$Y is available since the current probe prototype was optimized for the emission spectrum of this radio-nuclide. Here we study, with a set of laboratory tests and simulations, the prototype capability in case a different radio-nuclide is chosen among those used in nuclear medicine.
As a result we estimate the probe efficiency on electrons and photons as a function of energy and we evaluate the feasibility of a radio-guided surgery exploiting the selected radio-nuclides. We conclude that requiring a 0.1~ml residue to be detected within 1~s by administering 3~MBq/Kg of radio-isotope, the current probe prototype would yield a significant signal in a vast range of values of SUV and TNR in case $^{31}$Si,$^{32}$P, $^{97}$Zr, and $^{188}$Re are used. Conversely, a tuning of the detector would be needed to efficiency use $^{83}$Br, $^{133}$I, and $^{153}$Sm, although they could already be used in case of high SUV or TNR values. Finally, $^{18}$F,$^{67}$Cu, $^{131}$I, and $^{177}$Lu are not useable for radio-guided surgery with the current probe design.
△ Less
Submitted 28 October, 2016;
originally announced October 2016.
-
First Ex-Vivo Validation of a Radioguided Surgery Technique with beta- Radiation
Authors:
E. Solfaroli Camillocci,
M. Schiariti,
V. Bocci,
A. Carollo,
G. Chiodi,
M. Colandrea,
F. Collamati,
M. Cremonesi,
R. Donnarumma,
M. E. Ferrari,
P. Ferroli,
F. Ghielmetti,
C. M. Grana,
M. Marafini,
S. Morganti,
C. Mancini Terracciano,
M. Patanè,
G. Pedroli,
B. Pollo,
L. Recchia,
A. Russomando,
M. Toppi,
G. Traini,
R. Faccini
Abstract:
Purpose: A radio-guided surgery technique with beta- -emitting radio-tracers was suggested to overcome the effect of the large penetration of gamma radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an…
▽ More
Purpose: A radio-guided surgery technique with beta- -emitting radio-tracers was suggested to overcome the effect of the large penetration of gamma radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an ex-vivo test on a meningioma patient. This test allowed to validate the whole chain, from the evaluation of the SUV of the tumor, to the assumptions on the bio-distribution and the signal detection.
Methods: A patient affected by meningioma was administered 300 MBq of 90Y-DOTATOC. Several samples extracted from the meningioma and the nearby Dura Mater were analyzed with a beta- probe designed specifically for this radio-guided surgery technique. The observed signals were compared both with the evaluation from the histology and with the Monte Carlo simulation.
Results: we obtained a large signal on the bulk tumor (105 cps) and a significant signal on residuals of $\sim$0.2 ml (28 cps). We also show that simulations predict correctly the observed yields and this allows us to estimate that the healthy tissues would return negligible signals (~1 cps). This test also demonstrated that the exposure of the medical staff is negligible and that among the biological wastes only urine has a significant activity.
Conclusions: This proof-of-principle test on a patient assessed that the technique is feasible with negligible background to medical personnel and confirmed that the expectations obtained with Monte Carlo simulations starting from diagnostic PET images are correct.
△ Less
Submitted 30 August, 2016;
originally announced August 2016.
-
Secondary radiation measurements for particle therapy applications: nuclear fragmentation produced by $^4$He ion beams in a PMMA target
Authors:
M. Marafini,
R. Paramatti,
D. Pinci,
G. Battistoni,
F. Collamati,
E. De Lucia,
R. Faccini,
P. M. Frallicciardi,
C. Mancini-Terracciano,
I. Mattei,
S. Muraro,
L. Piersanti,
M. Rovituso,
A. Rucinski,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
M. Toppi,
G. Traini,
C. Voena,
V. Patera
Abstract:
Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atom…
▽ More
Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atomic nuclei in the patient body. In this paper the results of measurements performed at the Heidelberg Ion-Beam Therapy center are reported. For the first time the absolute fluxes and the energy spectra of the fragments - protons, deuterons, and tritons - produced by $^4$He ion beams of 102, 125 and 145 MeV/u energies on a poly-methyl methacrylate target were evaluated at different angles. The obtained results are particularly relevant in view of the necessary optimization and review of the Treatment Planning Software being developed for clinical use of $^4$He beams in clinical routine and the relative benchmarking of Monte Carlo algorithm predictions.
△ Less
Submitted 29 August, 2016;
originally announced August 2016.
-
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 4He and 12C ion beams in a PMMA target at large angle
Authors:
A. Rucinski,
E. De Lucia,
G. Battistoni,
F. Collamati,
R. Faccini,
P. M. Frallicciardi,
C. Mancini-Terracciano,
M. Marafini,
I. Mattei,
S. Muraro,
R. Paramatti,
L. Piersanti,
D. Pinci,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
M. Toppi,
G. Traini,
C. Voena,
V. Patera
Abstract:
Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. T…
▽ More
Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. The secondary yields of protons produced along the primary beam path in PMMA target were obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The measured charged secondary yields and emission profiles are in agreement with the results reported in literature and confirm the feasibility of ion beam therapy range monitoring using 12C ion beam. The feasibility of range monitoring using charged secondary particles is also suggested for 4He ion beam.
△ Less
Submitted 16 August, 2016;
originally announced August 2016.
-
Design of a new tracking device for on-line dose monitor in ion therapy
Authors:
Giacomo Traini,
Giuseppe Battistoni,
Angela Bollella,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Fernando Ferroni,
Paola Maria Frallicciardi,
Carlo Mancini-Terracciano,
Michela Marafini,
Ilaria Mattei,
Federico Miraglia,
Silvia Muraro,
Riccardo Paramatti,
Luca Piersanti,
Davide Pinci,
Antoni Rucinski,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Martina Senzacqua,
Elena Solfaroli-Camillocci,
Marco Toppi,
Cecilia Voena,
Vincenzo Patera
Abstract:
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam in…
▽ More
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam interactions in the patient tissues. In fact, the charged particle emission shape can be correlated with the spatial dose release and the Bragg peak position. The detector uses the information provided by 12 layers of scintillating fibers followed by a plastic scintillator and a small calorimeter made of a pixelated Lutetium Fine Silicate crystal. Simulations have been performed to evaluate the achievable spatial resolution and a possible application of the device for the monitoring of the dose profile in a real treatment is presented.
△ Less
Submitted 28 July, 2016;
originally announced July 2016.
-
Secondary radiation measurements for particle therapy applications: prompt photons produced by $^{4}$He, $^{12}$C and $^{16}$O ion beams in a PMMA target
Authors:
Ilaria Mattei,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Paola Maria Frallicciardi,
Carlo Mancini-Terracciano,
Michela Marafini,
Silvia Muraro,
Riccardo Paramatti,
Vincenzo Patera,
Luca Piersanti,
Davide Pinci,
Antoni Rucinski,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Elena Solfaroli Camillocci,
Marco Toppi,
Giacomo Traini,
Cecilia Voena,
Giuseppe Battistoni
Abstract:
Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of heli…
▽ More
Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of helium and oxygen beams is growing due to their reduced multiple scattering inside the body and increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands for online dose monitoring techniques, crucial to improve the quality assurance of treatments. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Prompt photons are produced by nuclear de-excitation processes and, at present, different dose monitoring and beam range verification techniques based on the prompt γ detection have been proposed. It is hence of importance to perform the γ yield measurement in therapeutical-like conditions. In this paper we report the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a PMMA target. The measurements were performed at the Heidelberg Ion-beam Therapy center (HIT) with beams of different energies. A LYSO scintillator has been used as photon detector. The obtained γ yields for $^{12}$C ion beams are compared with results from literature, while no other results from $^{4}$He and $^{16}$O beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-γ based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.
△ Less
Submitted 19 July, 2016; v1 submitted 26 May, 2016;
originally announced May 2016.
-
Polycrystalline para-terphenyl scintillator adopted in a $β^-$ detecting probe for radio-guided surgery
Authors:
Elena Solfaroli Camillocci,
Fabio Bellini,
Valerio Bocci,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Michela Marafini,
Ilaria Mattei,
Silvio Morganti,
Riccardo Paramatti,
Vincenzo Patera,
Davide Pinci,
Luigi Recchia,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Martina Senzacqua,
Cecilia Voena
Abstract:
A radio-guided surgery technique exploiting $β^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique to cases with a large uptake of surrounding healthy organs. Such technique requires a dedicated intraoperative probe detecting $β^-$ radiation. A first prototype h…
▽ More
A radio-guided surgery technique exploiting $β^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique to cases with a large uptake of surrounding healthy organs. Such technique requires a dedicated intraoperative probe detecting $β^-$ radiation. A first prototype has been developed relying on the low density and high light yield of the diphenylbutadiene doped para-therphenyl organic scintillator. The scintillation light produced in a cylindrical crystal, 5 mm in diameter and 3 mm in height, is guided to a photo-multiplier tube by optical fibres. The custom readout electronics is designed to optimize its usage in terms of feedback to the surgeon, portability and remote monitoring of the signal. Tests show that with a radiotracer activity comparable to those administered for diagnostic purposes the developed probe can detect a 0.1 ml cancerous residual of meningioma in a few seconds.
△ Less
Submitted 9 November, 2015;
originally announced November 2015.
-
An Intraoperative $β^-$ Detecting Probe For Radio-Guided Surgery in Tumour Resection
Authors:
Andrea Russomando,
Fabio Bellini,
Valerio Bocci,
Giacomo Chiodi,
Francesco Collamati,
Erika De Lucia,
Raffaella Donnarumma,
Riccardo Faccini,
Carlo Mancini Terracciano,
Michela Marafini,
Riccardo Paramatti,
Vincenzo Patera,
%Davide Pinci,
Luigi Recchia,
Alessio Sarti,
Adalberto Sciubba,
Elena Solfaroli Camillocci,
Cecilia Voena,
Silvio Morganti
Abstract:
The development of the $β^-$ based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To vali…
▽ More
The development of the $β^-$ based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To validate the technique, prototypes of the intraoperative probe required by the technique to detect $β^-$ radiation have been developed. This paper discusses the design details of the device and the tests performed in laboratory. In such tests particular care has to be taken to reproduce the surgical field conditions. The innovative technique to produce specific phantoms and the dedicated testing protocols is described in detail.
△ Less
Submitted 6 November, 2015;
originally announced November 2015.
-
Towards a Radio-guided Surgery with $β^{-}$ Decays: Uptake of a somatostatin analogue (DOTATOC) in Meningioma and High Grade Glioma
Authors:
Francesco Collamati,
Alessandra Pepe,
Fabio Bellini,
Valerio Bocci,
Marta Cremonesi,
Erika De Lucia,
Mahila Ferrari,
Paola M. Frallicciardi,
Chiara M. Grana,
Michela Marafini,
Ilaria Mattei,
Silvio Morganti,
Vincenzo Patera,
Luca Piersanti,
Luigi Recchia,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Martina Senzacqua,
Elena Solfaroli Camillocci,
Cecilia Voena,
Riccardo Faccini
Abstract:
A novel radio guided surgery (RGS) technique for cerebral tumors using $β^{-}$ radiation is being developed. Checking the availability of a radio-tracer that can deliver a $β^{-}$ emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study…
▽ More
A novel radio guided surgery (RGS) technique for cerebral tumors using $β^{-}$ radiation is being developed. Checking the availability of a radio-tracer that can deliver a $β^{-}$ emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study of the RGS technique in these cases.
△ Less
Submitted 23 December, 2014;
originally announced December 2014.
-
A novel radioguided surgery technique exploiting $β^{-}$ decays
Authors:
E. Solfaroli Camillocci,
G. Baroni,
F. Bellini,
V. Bocci,
F. Collamati,
M. Cremonesi,
E. De Lucia,
P. Ferroli,
S. Fiore,
C. M. Grana,
M. Marafini,
I. Mattei,
S. Morganti,
G. Paganelli,
V. Patera,
L. Piersanti,
L. Recchia,
A. Russomando,
M. Schiariti,
A. Sarti,
A. Sciubba,
C. Voena,
R. Faccini
Abstract:
The background induced by the high penetration power of the gamma radiation is the main limiting factor of the current Radio-guided surgery (RGS). To partially mitigate it, a RGS with beta+ emitting radio-tracers has been suggested in literature.
Here we propose the use of beta- emitting radio-tracers and beta- probes and discuss the advantage of this method with respect to the previously explor…
▽ More
The background induced by the high penetration power of the gamma radiation is the main limiting factor of the current Radio-guided surgery (RGS). To partially mitigate it, a RGS with beta+ emitting radio-tracers has been suggested in literature.
Here we propose the use of beta- emitting radio-tracers and beta- probes and discuss the advantage of this method with respect to the previously explored ones: the electron low penetration power allows for simple and versatile probes and could extend RGS to tumours for which background originating from nearby healthy tissue makes gamma probes less effective. We developed a beta- probe prototype and studied its performances on phantoms. By means of a detailed simulation we have also extrapolated the results to estimate the performances in a realistic case of meningioma, pathology which is going to be our first in-vivo test case. A good sensitivity to residuals down to 0.1ml can be reached within 1s with an administered activity smaller than those for PET-scans thus making the radiation exposure to medical personnel negligible.
△ Less
Submitted 10 February, 2014;
originally announced February 2014.
-
Further investigations on the Neutron Flux Generation in a Plasma Discharge Electrolytic Cell
Authors:
R. Faccini,
A. Pilloni,
A. D. Polosa,
M. Angelone,
E. Castagna,
S. Lecci,
S. Loreti,
A. Pietropaolo,
M. Pillon,
M. Sansovini,
F. Sarto,
V. Violante,
R. Bedogni,
A. Esposito
Abstract:
Our recent paper on the "Search for Neutron Flux Generation in a Plasma Discharge Electrolytic Cell" [1] has as main goal the validation of the experiment in Ref.[2]. As a follow-up, Ref.[3] moves a set of objections on our procedure and presents argumentations on why the experiments should not yield the same results. We collect here additional material and calculations that contribute to understa…
▽ More
Our recent paper on the "Search for Neutron Flux Generation in a Plasma Discharge Electrolytic Cell" [1] has as main goal the validation of the experiment in Ref.[2]. As a follow-up, Ref.[3] moves a set of objections on our procedure and presents argumentations on why the experiments should not yield the same results. We collect here additional material and calculations that contribute to understanding the observed discrepancies. Furthermore we prove that the absence of signals from Indium activation detectors reported also for the experiment of Ref.[2] is a clear indication that neutron production does not occur.
[1] R.Faccini et al arXiv:1310.4749
[2] D.Cirillo et al, Key Engineering Materials 495, 104 (2012).
[3] A.Widom et al. arXiv:1311.2447
△ Less
Submitted 30 January, 2014;
originally announced January 2014.
-
Search for Neutron Flux Generation in a Plasma Discharge Electrolytic Cell
Authors:
R. Faccini,
A. Pilloni,
A. D. Polosa,
M. Angelone,
E. Castagna,
S. Lecci,
A. Pietropaolo,
M. Pillon,
M. Sansovini,
F. Sarto,
V. Violante,
R. Bedogni,
A. Esposito
Abstract:
Following some recent unexpected hints of neutron production in setups like high-voltage atmospheric discharges and plasma discharges in electrolytic cells, we present a measurement of the neutron flux in a configuration similar to the latter. We use two different types of neutron detectors, poly-allyl-diglicol-carbonate (PADC, aka CR-39) tracers and Indium disks. At 95% C.L. we provide an upper l…
▽ More
Following some recent unexpected hints of neutron production in setups like high-voltage atmospheric discharges and plasma discharges in electrolytic cells, we present a measurement of the neutron flux in a configuration similar to the latter. We use two different types of neutron detectors, poly-allyl-diglicol-carbonate (PADC, aka CR-39) tracers and Indium disks. At 95% C.L. we provide an upper limit of 1.5 neutrons cm^-2 s^-1 for the thermal neutron flux at ~5 cm from the center of the cell. Allowing for a higher energy neutron component the largest allowed flux is 64 neutrons cm^-2 s^-1. This upper limit is two orders of magnitude smaller than what previously claimed in an electrolytic cell plasma discharge experiment. Furthermore the behavior of the CR-39 is discussed to point our possible sources of spurious signals.
△ Less
Submitted 17 October, 2013;
originally announced October 2013.
-
IRIDE White Book, An Interdisciplinary Research Infrastructure based on Dual Electron linacs&lasers
Authors:
D. Alesini,
M. Alessandroni,
M. P. Anania,
S. Andreas,
M. Angelone,
A. Arcovito,
F. Arnesano,
M. Artioli,
L. Avaldi,
D. Babusci,
A. Bacci,
A. Balerna,
S. Bartalucci,
R. Bedogni,
M. Bellaveglia,
F. Bencivenga,
M. Benfatto,
S. Biedron,
V. Bocci,
M. Bolognesi,
P. Bolognesi,
R. Boni,
R. Bonifacio,
M. Boscolo,
F. Boscherini
, et al. (189 additional authors not shown)
Abstract:
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high ener…
▽ More
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of science and technology. IRIDE will contribute to open new avenues of discoveries and to address most important riddles: What does matter consist of? What is the structure of proteins that have a fundamental role in life processes? What can we learn from protein structure to improve the treatment of diseases and to design more efficient drugs? But also how does an electronic chip behave under the effect of radiations? How can the heat flow in a large heat exchanger be optimized? The scientific potential of IRIDE is far reaching and justifies the construction of such a large facility in Italy in synergy with the national research institutes and companies and in the framework of the European and international research. It will impact also on R&D work for ILC, FEL, and will be complementarity to other large scale accelerator projects. IRIDE is also intended to be realized in subsequent stages of development depending on the assigned priorities.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.
-
Extended calibration range for prompt photon emission in ion beam irradiation
Authors:
F. Bellini,
T. T. Boehlen,
M. P. W. Chin,
F. Collamati,
E. De Lucia,
R. Faccini,
A. Ferrari,
L. Lanza,
C. Mancini-Terraciano,
M. Marafini,
I. Mattei,
S. Morganti,
P. G. Ortega,
V. Patera,
L. Piersanti,
A. Russomando,
P. R. Sala,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
C. Voena
Abstract:
Monitoring the dose delivered during proton and carbon ion therapy is still a matter of research. Among the possible solutions, several exploit the measurement of the single photon emission from nuclear decays induced by the irradiation. To fully characterize such emission the detectors need development, since the energy spectrum spans the range above the MeV that is not traditionally used in medi…
▽ More
Monitoring the dose delivered during proton and carbon ion therapy is still a matter of research. Among the possible solutions, several exploit the measurement of the single photon emission from nuclear decays induced by the irradiation. To fully characterize such emission the detectors need development, since the energy spectrum spans the range above the MeV that is not traditionally used in medical applications. On the other hand, a deeper understanding of the reactions involving gamma production is needed in order to improve the physic models of Monte Carlo codes, relevant for an accurate prediction of the prompt-gamma energy spectrum.This paper describes a calibration technique tailored for the range of energy of interest and reanalyzes the data of the interaction of a 80MeV/u fully stripped carbon ion beam with a Poly-methyl methacrylate target. By adopting the FLUKA simulation with the appropriate calibration and resolution a significant improvement in the agreement between data and simulation is reported.
△ Less
Submitted 22 July, 2013;
originally announced July 2013.
-
SuperB Technical Design Report
Authors:
SuperB Collaboration,
M. Baszczyk,
P. Dorosz,
J. Kolodziej,
W. Kucewicz,
M. Sapor,
A. Jeremie,
E. Grauges Pous,
G. E. Bruno,
G. De Robertis,
D. Diacono,
G. Donvito,
P. Fusco,
F. Gargano,
F. Giordano,
F. Loddo,
F. Loparco,
G. P. Maggi,
V. Manzari,
M. N. Mazziotta,
E. Nappi,
A. Palano,
B. Santeramo,
I. Sgura,
L. Silvestris
, et al. (384 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch…
▽ More
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented.
A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
-
Properties of para-terphenyl as detector for alpha, beta and gamma radiation
Authors:
M. Angelone,
G. Battistoni,
F. Bellini,
V. Bocci,
F. Collamati,
E. De Lucia,
R. Faccini,
F. Ferroni,
S. Fiore,
M. Marafini,
D. Materazzo,
I. Mattei,
S. Morganti,
V. Patera,
L. Piersanti,
M. Pillon,
L. Recchia,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
C. Voena
Abstract:
Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a blend of properties of the two categories that can be optimal for energy and position measurements of low energy charged particles. On 0.1% diphenylbutadiene doped…
▽ More
Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a blend of properties of the two categories that can be optimal for energy and position measurements of low energy charged particles. On 0.1% diphenylbutadiene doped para-terphenyl samples we measure a light yield 3.5+-0.2 times larger than a typical organic scintillator (EJ-200), and a rejection power for 660 keV photons, with respect to electrons of the same energy, ranging between 3-11%, depending on the signal threshold. We also measure a light attenuation length = 4.73+-0.06 mm and we demonstrate that, with the measurements performed in this paper, a simulation based on FLUKA can properly reproduce the measured spectra.
△ Less
Submitted 2 May, 2013;
originally announced May 2013.
-
Validation of techniques to mitigate copper surface contamination in CUORE
Authors:
F. Alessandria,
R. Ardito,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
T. Bloxham,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (93 additional authors not shown)
Abstract:
In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a dedicated test apparatus constructed to validate and compare these techniques we demonstrate that copper surface contamination levels better than 10E-07 - 10E-…
▽ More
In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a dedicated test apparatus constructed to validate and compare these techniques we demonstrate that copper surface contamination levels better than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit on the number of background counts in the region of interest is 0.02-0.03 counts/keV/kg/y depending on the adopted mitigation technique.
△ Less
Submitted 4 April, 2013; v1 submitted 3 October, 2012;
originally announced October 2012.
-
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
Authors:
F. Alessandria,
R. Ardito,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
T. Bloxham,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (91 additional authors not shown)
Abstract:
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data…
▽ More
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data from the finished CUORICINO experiment. Finally, we report the expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers) experiments to a WIMP annual modulation signal.
△ Less
Submitted 1 February, 2013; v1 submitted 12 September, 2012;
originally announced September 2012.
-
Dependence of the energy resolution of a scintillating crystal on the readout integration time
Authors:
V. Bocci,
D. Chao,
G. Chiodi,
R. Faccini,
F. Ferroni,
R. Lunadei,
G. Martellotti,
G. Penso,
D. Pinci,
L. Recchia
Abstract:
The possibilty of performing high-rate calorimetry with a slow scintillator crystal is studied. In this experimental situation, to avoid pulse pile-up, it can be necessary to base the energy measurement on only a fraction of the emitted light, thus spoiling the energy resolution. This effect was experimentally studied with a BGO crystal and a photomultiplier followed by an integrator, by measuring…
▽ More
The possibilty of performing high-rate calorimetry with a slow scintillator crystal is studied. In this experimental situation, to avoid pulse pile-up, it can be necessary to base the energy measurement on only a fraction of the emitted light, thus spoiling the energy resolution. This effect was experimentally studied with a BGO crystal and a photomultiplier followed by an integrator, by measuring the peak amplitude of the signals. The experimental data show that the energy resolution is exclusively due to the statistical fluctuations of the number of photoelectrons contributing to the peak amplitude. When such number is small its fluctuations are even smaller than those predicted by Poisson statistics. These results were confirmed by a Monte Carlo simulation which allows to estimate, in a general case, the energy resolution, given the total number of photoelectrons, the scintillation time and the integration time.
△ Less
Submitted 31 August, 2012; v1 submitted 20 July, 2012;
originally announced July 2012.
-
Charged particle's flux measurement from PMMA irradiated by 80 MeV/u carbon ion beam
Authors:
C. Agodi,
G. Battistoni,
F. Bellini,
G. A. P. Cirrone,
F. Collamati,
G. Cuttone,
E. De Lucia,
M. De Napoli,
A. Di Domenico,
R. Faccini,
F. Ferroni,
S. Fiore,
P. Gauzzi,
E. Iarocci,
M. Marafini,
I. Mattei,
S. Muraro,
A. Paoloni,
V. Patera,
L. Piersanti,
F. Romano,
A. Sarti,
A. Sciubba,
E. Vitale,
C. Voena
Abstract:
Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance i…
▽ More
Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance in the design of any dose monitoring device and is eagerly needed to tune Monte Carlo simulations. We report the measurements done with charged secondary particles produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the INFN Laboratori Nazionali del Sud, Catania, with a Poly-methyl methacrylate target. Charged secondary particles, produced at 90$\degree$ with respect to the beam axis, have been tracked with a drift chamber, while their energy and time of flight has been measured by means of a LYSO scintillator. Secondary protons have been identified exploiting the energy and time of flight information, and their emission region has been reconstructed backtracking from the drift chamber to the target. Moreover a position scan of the target indicates that the reconstructed emission region follows the movement of the expected Bragg peak position. Exploting the reconstruction of the emission region, an accuracy on the Bragg peak determination in the submillimeter range has been obtained. The measured differential production rate for protons produced with $E^{\rm Prod}_{\rm kin} >$ 83 MeV and emitted at 90$\degree$ with respect to the beam line is: $dN_{\rm P}/(dN_{\rm C}dΩ)(E^{\rm Prod}_{\rm kin} > 83 {\rm ~MeV}, θ=90\degree)= (2.69\pm 0.08_{\rm stat} \pm 0.12_{\rm sys})\times 10^{-4} sr^{-1}$.
△ Less
Submitted 21 March, 2012;
originally announced March 2012.
-
Study of the time and space distribution of beta+ emitters from 80 MeV/u carbon ion beam irradiation on PMMA
Authors:
C. Agodi,
F. Bellini,
G. A. P. Cirrone,
F. Collamati,
G. Cuttone,
E. De Lucia,
M. De Napoli,
A. Di Domenico,
R. Faccini,
F. Ferroni,
S. Fiore,
P. Gauzzi,
E. Iarocci,
M. Marafini,
I. Mattei,
A. Paoloni,
V. Patera,
L. Piersanti,
F. Romano,
A. Sarti,
A. Sciubba,
C. Voena
Abstract:
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear $511\ \kilo\electronvolt$ photons produced by positrons annihilation from $β^+$ emitters created by the beam. This p…
▽ More
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear $511\ \kilo\electronvolt$ photons produced by positrons annihilation from $β^+$ emitters created by the beam. This paper reports rate measurements of the $511\ \kilo\electronvolt$ photons emitted after the interactions of a $80\ \mega\electronvolt / u$ fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a Poly-methyl methacrylate target. The time evolution of the $β^+$ rate was parametrized and the dominance of $^{11}C$ emitters over the other species ($^{13}N$, $^{15}O$, $^{14}O$) was observed, measuring the fraction of carbon ions activating $β^+$ emitters $A_0=(10.3\pm0.7)\cdot10^{-3}$. The average depth in the PMMA of the positron annihilation from $β^+$ emitters was also measured, $D_{β^+}=5.3\pm1.1\ \milli\meter$, to be compared to the expected Bragg peak depth $D_{Bragg}=11.0\pm 0.5\ \milli\meter$ obtained from simulations.
△ Less
Submitted 27 April, 2012; v1 submitted 8 February, 2012;
originally announced February 2012.
-
Precise measurement of prompt photon emission for carbon ion therapy
Authors:
C. Agodi,
F. Bellini,
G. A. P. Cirrone,
F. Collamati,
G. Cuttone,
E. De Lucia,
M. De Napoli,
A. Di Domenico,
R. Faccini,
F. Ferroni,
S. Fiore,
P. Gauzzi,
E. Iarocci,
M. Marafini,
I. Mattei,
A. Paoloni,
V. Patera,
L. Piersanti,
F. Romano,
A. Sarti,
A. Sciubba,
C. Voena
Abstract:
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments is still a matter of research. A possible technique exploits the information provided by single photon emission from nuclear decays induced by the irradiation. This paper reports the measurements of the spectrum and rate of such photons produce…
▽ More
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments is still a matter of research. A possible technique exploits the information provided by single photon emission from nuclear decays induced by the irradiation. This paper reports the measurements of the spectrum and rate of such photons produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the Laboratori Nazionali del Sud of INFN, Catania, with a Poly-methyl methacrylate target. The differential production rate for photons with energy E > 2 MeV and emitted at 90 degree is found to be $dN_γ/(dN_C dΩ)=(2.92\pm 0.19)\times 10^{-2}$sr$^{-1}$.
△ Less
Submitted 17 October, 2011;
originally announced October 2011.
-
Multi-GeV Electron Spectrometer
Authors:
R. Faccini,
F. Anelli,
A. Bacci,
D. Batani,
M. Bellaveglia,
R. Benocci,
C. Benedetti,
L. Cacciotti,
C. A. Cecchetti,
A. Clozza,
L. Cultrera,
G. Di~Pirro,
N. Drenska,
F. Anelli,
M. Ferrario,
D. Filippetto,
S. Fioravanti,
A. Gallo,
A. Gamucci,
G. Gatti,
A. Ghigo,
A. Giulietti,
D. Giulietti,
L. A. Gizzi,
P. Koester
, et al. (13 additional authors not shown)
Abstract:
The advance in laser plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1pC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected.…
▽ More
The advance in laser plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1pC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction of such a device. We will present the design considerations for this spectrometer and the first results from a prototype.
△ Less
Submitted 18 February, 2010;
originally announced February 2010.
-
Silicon Photo-Multiplier radiation hardness tests with a beam controlled neutron source
Authors:
M. Angelone,
M. Pillon,
R. Faccini,
D. Pinci,
W. Baldini,
R. Calabrese,
G. Cibinetto,
A. Cotta Ramusino,
R. Malaguti,
M. Pozzati
Abstract:
We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to 7x10^10 1-MeV-equivalent neutrons per cm^2. Detector performances have been recorded during the neu…
▽ More
We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to 7x10^10 1-MeV-equivalent neutrons per cm^2. Detector performances have been recorded during the neutron irradiation and a gradual deterioration of their properties was found to happen already after an integrated fluence of the order of 10^8 1-MeV-equivalent neutrons per cm^2.
△ Less
Submitted 8 June, 2010; v1 submitted 18 February, 2010;
originally announced February 2010.