Euclid preparation. LensMC, weak lensing cosmic shear measurement with forward modelling and Markov Chain Monte Carlo sampling
Authors:
Euclid Collaboration,
G. Congedo,
L. Miller,
A. N. Taylor,
N. Cross,
C. A. J. Duncan,
T. Kitching,
N. Martinet,
S. Matthew,
T. Schrabback,
M. Tewes,
N. Welikala,
N. Aghanim,
A. Amara,
S. Andreon,
N. Auricchio,
M. Baldi,
S. Bardelli,
R. Bender,
C. Bodendorf,
D. Bonino,
E. Branchini,
M. Brescia,
J. Brinchmann,
S. Camera
, et al. (217 additional authors not shown)
Abstract:
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling to deal with convolution by a point spread function with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies observed by Eu…
▽ More
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling to deal with convolution by a point spread function with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies observed by Euclid. The scientific performance is quantified through high-fidelity images based on the Euclid Flagship simulations and emulation of the Euclid VIS images; realistic clustering with a mean surface number density of 250 arcmin$^{-2}$ ($I_{\rm E}<29.5$) for galaxies, and 6 arcmin$^{-2}$ ($I_{\rm E}<26$) for stars; and a diffraction-limited chromatic point spread function with a full width at half maximum of $0.^{\!\prime\prime}2$ and spatial variation across the field of view. Objects are measured with a density of 90 arcmin$^{-2}$ ($I_{\rm E}<26.5$) in 4500 deg$^2$. The total shear bias is broken down into measurement (our main focus here) and selection effects (which will be addressed elsewhere). We find: measurement multiplicative and additive biases of $m_1=(-3.6\pm0.2)\times10^{-3}$, $m_2=(-4.3\pm0.2)\times10^{-3}$, $c_1=(-1.78\pm0.03)\times10^{-4}$, $c_2=(0.09\pm0.03)\times10^{-4}$; a large detection bias with a multiplicative component of $1.2\times10^{-2}$ and an additive component of $-3\times10^{-4}$; and a measurement PSF leakage of $α_1=(-9\pm3)\times10^{-4}$ and $α_2=(2\pm3)\times10^{-4}$. When model bias is suppressed, the obtained measurement biases are close to Euclid requirement and largely dominated by undetected faint galaxies ($-5\times10^{-3}$). Although significant, model bias will be straightforward to calibrate given the weak sensitivity.
△ Less
Submitted 1 May, 2024;
originally announced May 2024.
The long duration cryogenic system of the OLIMPO balloon--borne experiment: design and in--flight performance
Authors:
A. Coppolecchia,
L. Lamagna,
S. Masi,
P. A. R. Ade,
G. Amico,
E. S. Battistelli,
P. de Bernardis,
F. Columbro,
L. Conversi,
G. D'Alessandro,
M. De Petris,
M. Gervasi,
F. Nati,
L. Nati,
A. Paiella,
F. Piacentini,
G. Pisano,
G. Presta,
A. Schillaci,
C. Tucker,
M. Zannoni
Abstract:
We describe the design and in--flight performance of the cryostat and the self-contained $^{3}$He refrigerator for the OLIMPO balloon--borne experiment, a spectrophotometer to measure the Sunyaev-Zel'dovich effect in clusters of galaxies.
The $^{3}$He refrigerator provides the 0.3 K operation temperature for the four arrays of kinetic inductance detectors working in 4 bands centered at 150, 250,…
▽ More
We describe the design and in--flight performance of the cryostat and the self-contained $^{3}$He refrigerator for the OLIMPO balloon--borne experiment, a spectrophotometer to measure the Sunyaev-Zel'dovich effect in clusters of galaxies.
The $^{3}$He refrigerator provides the 0.3 K operation temperature for the four arrays of kinetic inductance detectors working in 4 bands centered at 150, 250, 350 and 460 GHz. The cryostat provides the 1.65 K base temperature for the $^{3}$He refrigerator, and cools down the reimaging optics and the filters chain at about 2 K.
The integrated system was designed for a hold time of about 15 days, to achieve the sensitivity required by the planned OLIMPO observations, and successfully operated during the first long-duration stratospheric flight of OLIMPO in July 2018.
The cryostat features two tanks, one for liquid nitrogen and the other one for liquid helium. The long hold time has been achieved by means of custom stiff G10 fiberglass tubes support, which ensures low thermal conductivity and remarkable structural stiffness; multi--layer superinsulation, and a vapour cooled shield, all reducing the heat load on the liquid helium tank.
The system was tested in the lab, with more than 15 days of unmanned operations, and then in the long duration balloon flight in the stratosphere. In both cases, the detector temperature was below 300 mK, with thermal stability better than $\pm$ 0.5 mK.
The system also operated successfully in the long duration stratospheric balloon flight.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.