Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–37 of 37 results for author: Dahl, C E

Searching in archive physics. Search in all archives.
.
  1. arXiv:2408.17391  [pdf, other

    nucl-ex physics.ins-det

    Two-neutrino double electron capture of $^{124}$Xe in the first LUX-ZEPLIN exposure

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, J. W. Bargemann, E. E. Barillier, K. Beattie, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, E. Bishop, G. M. Blockinger, B. Boxer, C. A. J. Brew , et al. (180 additional authors not shown)

    Abstract: The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of $^{124}$Xe through the process of two-neutrino double electron capture (2$ν$2EC), utilizing a $1.39\,\mathrm{kg} \times \mathrm{yr}$ isotopic exposure from the first LZ science run. A half-life of… ▽ More

    Submitted 30 August, 2024; originally announced August 2024.

    Comments: 15 pages, 3 figures

  2. arXiv:2406.12874  [pdf, other

    physics.ins-det hep-ex

    The Design, Implementation, and Performance of the LZ Calibration Systems

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, E. E. Barillier, J. W. Bargemann, K. Beattie, T. Benson, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, E. Bishop, G. M. Blockinger, B. Boxer , et al. (179 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e… ▽ More

    Submitted 5 September, 2024; v1 submitted 2 May, 2024; originally announced June 2024.

    Journal ref: JINST 19 P08027 (2024)

  3. arXiv:2405.18403  [pdf, other

    physics.ins-det

    Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber

    Authors: H. Hawley-Herrera, E. Alfonso-Pita, E. Behnke, M. Bressler, B. Broerman, K. Clark, J. Corbett, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, P. Giampa, J. Hall, O. Harris, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott, X. Liu, N. Moss, R. Neilson, M. -C. Piro, D. Pyda, Z. Sheng, G. Sweeney , et al. (6 additional authors not shown)

    Abstract: The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage ($V_{\text{BD}}$), the SiPM gain (… ▽ More

    Submitted 22 July, 2024; v1 submitted 28 May, 2024; originally announced May 2024.

    Comments: 25 pages, 19 figures

    Report number: FERMILAB-PUB-24-0280-LDRD-PPD

  4. arXiv:2405.14732  [pdf, other

    physics.ins-det hep-ex

    The Data Acquisition System of the LZ Dark Matter Detector: FADR

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, E. E. Barillier, J. W. Bargemann, K. Beattie, T. Benson, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, E. Bishop, G. M. Blockinger, B. Boxer , et al. (191 additional authors not shown)

    Abstract: The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.… ▽ More

    Submitted 16 August, 2024; v1 submitted 23 May, 2024; originally announced May 2024.

    Comments: 18 pages, 24 figures

  5. arXiv:2211.17120  [pdf, other

    hep-ex physics.ins-det

    Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, J. Bang, J. W. Bargemann, A. Baxter, K. Beattie, P. Beltrame, E. P. Bernard, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, G. M. Blockinger, B. Boxer , et al. (178 additional authors not shown)

    Abstract: The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet… ▽ More

    Submitted 17 July, 2023; v1 submitted 30 November, 2022; originally announced November 2022.

    Comments: 25 pages, 15 figures

    Journal ref: Phys. Rev. D 108, 012010 (2023)

  6. arXiv:2209.14111  [pdf, ps, other

    hep-ex physics.ins-det

    Report of the Instrumentation Frontier Working Group for Snowmass 2021

    Authors: Phillip S. Barbeau, Petra Merkel, Jinlong Zhang, Darin Acosta, Anthony A. Affolder, Artur Apresyan, Marina Artuso, Vallary Bhopatkar, Stephen Butalla, Gabriella A. Carini, Thomas Cecil, Amy Connolly, C. Eric Dahl, Allison Deiana, Katherine Dunne, Carlos O. Escobar, Juan Estrada, Farah Fahim, James E. Fast, Maurice Garcia-Sciveres, Roxanne Guenette, Michael T. Hedges, Kent Irwin, Albrecht Karle, Wes Ketchum , et al. (20 additional authors not shown)

    Abstract: Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technol… ▽ More

    Submitted 3 November, 2022; v1 submitted 28 September, 2022; originally announced September 2022.

    Comments: 53 pages, 0 figures, contribution to Snowmass 2021

  7. arXiv:2208.11017  [pdf, other

    physics.ins-det

    Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors

    Authors: Carl Eric Dahl, Roxanne Guenette, Jennifer L. Raaf, D. Akerib, J. Asaadi, D. Caratelli, E. Church, M. Del Tutto, A. Fava, R. Gaitskell, G. K. Giovanetti, G. Giroux, D. Gonzalez Diaz, E. Gramellini, S. Haselschwardt, C. Jackson, B. J. P. Jones, A. Kopec, S. Kravitz, H. Lippincott, J. Liu, C. J. Martoff, A. Mastbaum, C. Montanari, M. Mooney , et al. (17 additional authors not shown)

    Abstract: Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particl… ▽ More

    Submitted 15 September, 2022; v1 submitted 23 August, 2022; originally announced August 2022.

    Comments: 20 pages, 1 figure

    Report number: FERMILAB-CONF-22-631-ND

  8. arXiv:2207.12400  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$ν$NS Detection

    Authors: E. Alfonso-Pita, M. Baker, E. Behnke, A. Brandon, M. Bressler, B. Broerman, K. Clark, R. Coppejans, J. Corbett, C. Cripe, M. Crisler, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, K. Foy, P. Giampa, J. Gresl, J. Hall, O. Harris, H. Hawley-Herrera, C. M. Jackson, M. Khatri, Y. Ko, N. Lamb , et al. (20 additional authors not shown)

    Abstract: The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This dev… ▽ More

    Submitted 29 September, 2022; v1 submitted 21 July, 2022; originally announced July 2022.

    Comments: 35 pages, 12 figures, contributed white paper to Snowmass 2021 (final version for Snowmass proceedings)

    Report number: FERMILAB-CONF-22-535-LDRD-PPD

  9. arXiv:2205.05771  [pdf, other

    physics.ins-det astro-ph.IM

    Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

    Authors: B. Ali, I. J. Arnquist, D. Baxter, E. Behnke, M. Bressler, B. Broerman, K. Clark, J. I. Collar, P. S. Cooper, C. Cripe, M. Crisler, C. E. Dahl, M. Das, D. Durnford, S. Fallows, J. Farine, R. Filgas, A. García-Viltres, F. Girard, G. Giroux, O. Harris, E. W. Hoppe, C. M. Jackson, M. Jin, C. B. Krauss , et al. (32 additional authors not shown)

    Abstract: The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct… ▽ More

    Submitted 7 November, 2022; v1 submitted 11 May, 2022; originally announced May 2022.

    Comments: 17 pages, 22 figures, 5 tables

  10. arXiv:2203.02309  [pdf, other

    physics.ins-det astro-ph.CO hep-ex nucl-ex

    A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

    Authors: J. Aalbers, K. Abe, V. Aerne, F. Agostini, S. Ahmed Maouloud, D. S. Akerib, D. Yu. Akimov, J. Akshat, A. K. Al Musalhi, F. Alder, S. K. Alsum, L. Althueser, C. S. Amarasinghe, F. D. Amaro, A. Ames, T. J. Anderson, B. Andrieu, N. Angelides, E. Angelino, J. Angevaare, V. C. Antochi, D. Antón Martin, B. Antunovic, E. Aprile, H. M. Araújo , et al. (572 additional authors not shown)

    Abstract: The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut… ▽ More

    Submitted 4 March, 2022; originally announced March 2022.

    Comments: 77 pages, 40 figures, 1262 references

    Report number: INT-PUB-22-003

    Journal ref: J. Phys. G: Nucl. Part. Phys. 50 (2023) 013001

  11. arXiv:2109.11487  [pdf, other

    physics.ins-det hep-ex

    Measurement of Charge and Light Yields for $^{127}$Xe L-Shell Electron Captures in Liquid Xenon

    Authors: Dylan J Temples, Jacob McLaughlin, Jack Bargemann, Daniel Baxter, Amy Cottle, C Eric Dahl, W Hugh Lippincott, Alissa Monte, Jason Phelan

    Abstract: Dark matter searches using dual-phase xenon time-projection chambers (LXe-TPCs) rely on their ability to reject background electron recoils (ERs) while searching for signal-like nuclear recoils (NRs). ER response is typically calibrated using $β$-decay sources, such as tritium, but these calibrations do not characterize events accompanied by an atomic vacancy, as in solar neutrino scatters off inn… ▽ More

    Submitted 14 December, 2021; v1 submitted 23 September, 2021; originally announced September 2021.

    Comments: 15 pages, 14 figures

    Report number: FERMILAB-PUB-21-397-E

    Journal ref: Phys. Rev. D 104, 112001 (2021)

  12. arXiv:2104.13374  [pdf, other

    physics.ins-det nucl-ex

    Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of $^{134}$Xe

    Authors: The LUX-ZEPLIN, Collaboration, :, D. S. Akerib, A. K. Al Musalhi, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araujo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, J. Bang, J. W. Bargemann, D. Bauer, A. Baxter, P. Beltrame, E. P. Bernard, A. Bernstein, A. Bhatti, A. Biekert , et al. (172 additional authors not shown)

    Abstract: The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity t… ▽ More

    Submitted 22 November, 2021; v1 submitted 26 April, 2021; originally announced April 2021.

    Comments: Version accepted for publication in Phys. Rev. C

  13. arXiv:2101.08785  [pdf, other

    hep-ex hep-ph nucl-ex physics.ins-det

    Physics reach of a low threshold scintillating argon bubble chamber in coherent elastic neutrino-nucleus scattering reactor experiments

    Authors: L. J. Flores, Eduardo Peinado, E. Alfonso-Pita, K. Allen, M. Baker, E. Behnke, M. Bressler, K. Clark, R. Coppejans, C. Cripe, M. Crisler, C. E. Dahl, A. de St. Croix, D. Durnford, P. Giampa, O. Harris, P. Hatch, H. Hawley, C. M. Jackson, Y. Ko, C. Krauss, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott , et al. (9 additional authors not shown)

    Abstract: The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the sig… ▽ More

    Submitted 26 May, 2021; v1 submitted 21 January, 2021; originally announced January 2021.

    Comments: 9 pages, 5 figures. v2: figures added, minor changes. Matches published version

    Journal ref: Phys. Rev. D 103, 091301 (2021)

  14. arXiv:2101.08753  [pdf, other

    astro-ph.IM physics.ins-det

    Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

    Authors: D. S. Akerib, A. K. Al Musalhi, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, J. Bang, J. W. Bargemann, D. Bauer, A. Baxter, P. Beltrame, E. P. Bernard, A. Bernstein, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, G. M. Blockinger , et al. (162 additional authors not shown)

    Abstract: Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matt… ▽ More

    Submitted 21 January, 2021; originally announced January 2021.

    Comments: 14 pages, 6 figures

  15. arXiv:2006.02506  [pdf, other

    physics.ins-det hep-ex

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, S. Aviles, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame, J. Bensinger , et al. (365 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent… ▽ More

    Submitted 28 February, 2022; v1 submitted 3 June, 2020; originally announced June 2020.

    Comments: 45 pages (79 inc. tables), 7 figures, 9 tables

    Journal ref: The European Physical Journal C, Volume 80, Article number: 1044 (2020)

  16. Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment

    Authors: The LUX-ZEPLIN Collaboration, :, D. S. Akerib, C. W. Akerlof, A. Alqahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, J. Bang, D. Bauer, A. Baxter, J. Bensinger, E. P. Bernard, A. Bernstein, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, K. E. Boast , et al. (173 additional authors not shown)

    Abstract: The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of par… ▽ More

    Submitted 23 June, 2020; v1 submitted 25 January, 2020; originally announced January 2020.

    Comments: 24 pages, 19 figures; Corresponding Authors: A. Cottle, V. Kudryavtsev, D. Woodward

  17. arXiv:1911.00762  [pdf, other

    physics.ins-det hep-ex hep-ph nucl-ex

    Coherent Elastic Neutrino-Nucleus Scattering at the European Spallation Source

    Authors: D. Baxter, J. I. Collar, P. Coloma, C. E. Dahl, I. Esteban, P. Ferrario, J. J. Gomez-Cadenas, M. C. Gonzalez-Garcia, A. R. L. Kavner, C. M. Lewis, F. Monrabal, J. Muñoz Vidal, P. Privitera, K. Ramanathan, J. Renner

    Abstract: The European Spallation Source (ESS), presently well on its way to completion, will soon provide the most intense neutron beams for multi-disciplinary science. Fortuitously, it will also generate the largest pulsed neutrino flux suitable for the detection of Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS), a process recently measured for the first time at ORNL's Spallation Neutron Source. W… ▽ More

    Submitted 3 February, 2020; v1 submitted 2 November, 2019; originally announced November 2019.

    Comments: 21 pages, 15 figures. v2: Minor changes, typo corrected in Fig 6. Version accepted for publication in JHEP

    Report number: IFIC/19-45, YITP-SB-19-37

    Journal ref: J. High Energ. Phys. 2020, 123 (2020)

  18. arXiv:1910.09124  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The LUX-ZEPLIN (LZ) Experiment

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, J. Barthel, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame , et al. (357 additional authors not shown)

    Abstract: We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n… ▽ More

    Submitted 3 November, 2019; v1 submitted 20 October, 2019; originally announced October 2019.

  19. arXiv:1910.07450  [pdf, other

    hep-ex astro-ph.IM hep-ph nucl-ex physics.ins-det

    Proceedings of The Magnificent CE$ν$NS Workshop 2018

    Authors: D. Aristizabal Sierra, A. B. Balantekin, D. Caratelli, B. Cogswell, J. I. Collar, C. E. Dahl, J. Dent, B. Dutta, J. Engel, J. Estrada, J. Formaggio, S. Gariazzo, R. Han, S. Hedges, P. Huber, A. Konovalov, R. F. Lang, S. Liao, M. Lindner, P. Machado, R. Mahapatra, D. Marfatia, I. Martinez-Soler, O. Miranda, D. Misiak , et al. (20 additional authors not shown)

    Abstract: The Magnificent CE$ν$NS Workshop (2018) was held November 2 & 3 of 2018 on the University of Chicago campus and brought together theorists, phenomenologists, and experimentalists working in numerous areas but sharing a common interest in the process of coherent elastic neutrino-nucleus scattering (CE$ν$NS). This is a collection of abstract-like summaries of the talks given at the meeting, includin… ▽ More

    Submitted 16 October, 2019; originally announced October 2019.

    Comments: The Magnificent CEvNS Workshop (2018), Nov 2-3, 2018; Chicago, IL, USA; 44 contributions

  20. arXiv:1905.12522  [pdf, ps, other

    physics.ins-det astro-ph.CO hep-ex hep-ph

    Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, S. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, R. Filgas , et al. (54 additional authors not shown)

    Abstract: The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by… ▽ More

    Submitted 25 November, 2020; v1 submitted 29 May, 2019; originally announced May 2019.

    Comments: 18 pages, 12 figures

    Journal ref: Phys. Rev. D 100, 082006 (2019)

  21. A buffer-free concept bubble chamber for PICO dark matter searches

    Authors: Matthew Bressler, Peter Campion, V. Scott Cushman, Alexander Morrese, Johannes M. Wagner, Salvatore Zerbo, Russell Neilson, Mike Crisler, C. Eric Dahl

    Abstract: In this paper, we report on the successful operation at Drexel University of the PICO collaboration's first C$_3$F$_8$ buffer-free prototype fluorocarbon bubble chamber. Previous PICO bubble chambers have produced world-leading WIMP search results with fluorocarbon target fluids, separated from the steel bellows by a buffer layer of water. Surface tension effects at the jar walls and liquid-liquid… ▽ More

    Submitted 28 July, 2019; v1 submitted 17 May, 2019; originally announced May 2019.

    Comments: For v2: figures updated for clarity and readability, some text updated with better explanations and references added. Results unchanged For v3: Bibliography formatting updated

  22. Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility

    Authors: D. S. Akerib, C. W. Akerlof, S. K. Alsum, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, A. Baxter, E. P. Bernard, A. Biekert, T. P. Biesiadzinski, K. E. Boast, B. Boxer, P. Brás, J. H. Buckley, V. V. Bugaev, S. Burdin, J. K. Busenitz, C. Carels, D. L. Carlsmith, M. C. Carmona-Benitez, M. Cascella , et al. (142 additional authors not shown)

    Abstract: Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located with… ▽ More

    Submitted 14 November, 2019; v1 submitted 3 April, 2019; originally announced April 2019.

    Comments: 11 pages, 9 figures

    Journal ref: Astroparticle Physics, Volume 116, Pages 102391 (2020)

  23. arXiv:1902.04031  [pdf, other

    astro-ph.CO hep-ex physics.ins-det

    Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis, R. Filgas , et al. (47 additional authors not shown)

    Abstract: Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr… ▽ More

    Submitted 11 February, 2019; originally announced February 2019.

    Comments: 9 pages, 8 figures

    Journal ref: Phys. Rev. D 100, 022001 (2019)

  24. arXiv:1811.11308  [pdf, other

    physics.comp-ph physics.ins-det

    Developing a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning

    Authors: B. Matusch, C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis , et al. (48 additional authors not shown)

    Abstract: The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually developing a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing… ▽ More

    Submitted 27 November, 2018; originally announced November 2018.

    Comments: 27 pages, 10 figures

  25. arXiv:1802.06039  [pdf, other

    astro-ph.IM astro-ph.CO hep-ex physics.ins-det

    Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment

    Authors: D. S. Akerib, C. W. Akerlof, S. K. Alsum, H. M. Araújo, M. Arthurs, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, D. Bauer, J. Belle, P. Beltrame, T. Benson, E. P. Bernard, T. P. Biesiadzinski, K. E. Boast, B. Boxer, P. Brás, J. H. Buckley, V. V. Bugaev, S. Burdin, J. K. Busenitz, C. Carels, D. L. Carlsmith, B. Carlson , et al. (153 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up… ▽ More

    Submitted 2 December, 2019; v1 submitted 16 February, 2018; originally announced February 2018.

    Comments: 14 pages, 11 figures

    Journal ref: Phys. Rev. D 101, 052002 (2020)

  26. arXiv:1703.09144  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Technical Design Report

    Authors: B. J. Mount, S. Hans, R. Rosero, M. Yeh, C. Chan, R. J. Gaitskell, D. Q. Huang, J. Makkinje, D. C. Malling, M. Pangilinan, C. A. Rhyne, W. C. Taylor, J. R. Verbus, Y. D. Kim, H. S. Lee, J. Lee, D. S. Leonard, J. Li, J. Belle, A. Cottle, W. H. Lippincott, D. J. Markley, T. J. Martin, M. Sarychev, T. E. Tope , et al. (237 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.

    Submitted 27 March, 2017; originally announced March 2017.

    Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>

    Report number: LBNL-1007256

  27. arXiv:1702.08861  [pdf, ps, other

    physics.ins-det astro-ph.CO hep-ex

    First Demonstration of a Scintillating Xenon Bubble Chamber for Detecting Dark Matter and Coherent Elastic Neutrino-Nucleus Scattering

    Authors: D. Baxter, C. J. Chen, M. Crisler, T. Cwiok, C. E. Dahl, A. Grimsted, J. Gupta, M. Jin, R. Puig, D. Temples, J. Zhang

    Abstract: A 30-g xenon bubble chamber, operated at Northwestern University in June and November 2016, has for the first time observed simultaneous bubble nucleation and scintillation by nuclear recoils in a superheated liquid. This chamber is instrumented with a CCD camera for near-IR bubble imaging, a solar-blind photomultiplier tube to detect 175-nm xenon scintillation light, and a piezoelectric acoustic… ▽ More

    Submitted 8 June, 2017; v1 submitted 28 February, 2017; originally announced February 2017.

    Comments: 6 pages, 4 figures. Published version

    Report number: FERMILAB-PUB-17-062-AE-E-PPD

    Journal ref: Phys. Rev. Lett. 118, 231301 (2017)

  28. arXiv:1702.07666  [pdf, ps, other

    astro-ph.CO hep-ex physics.ins-det

    Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, P. Campion, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, G. Crowder, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis, R. Filgas, F. Girard , et al. (37 additional authors not shown)

    Abstract: New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th… ▽ More

    Submitted 2 August, 2017; v1 submitted 24 February, 2017; originally announced February 2017.

    Comments: 6 pages, 6 figures

    Journal ref: Phys. Rev. Lett. 118, 251301 (2017)

  29. Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, I. J. Arnquist, M. Arthurs, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, J. Belle, P. Beltrame, T. Benson, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. Bolozdynya, B. Boxer, R. Bramante, P. Brás, J. H. Buckley, V. V. Bugaev , et al. (180 additional authors not shown)

    Abstract: The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,… ▽ More

    Submitted 26 September, 2017; v1 submitted 8 February, 2017; originally announced February 2017.

    Comments: 13 pages, 3 figures, accepted for publication in Astroparticle Physics

  30. arXiv:1601.03729  [pdf, other

    astro-ph.CO physics.ins-det

    Improved dark matter search results from PICO-2L Run 2

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, M. Das, F. Debris, S. Fallows, J. Farine, I. Felis, R. Filgas, M. Fines-Neuschild, F. Girard, G. Giroux , et al. (33 additional authors not shown)

    Abstract: New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nu… ▽ More

    Submitted 25 March, 2016; v1 submitted 14 January, 2016; originally announced January 2016.

    Journal ref: Phys. Rev. D 93, 061101 (2016)

  31. arXiv:1510.07754  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber

    Authors: C. Amole, M. Ardid, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, S. Daley, M. Das, F. Debris, N. Dhungana, J. Farine, I. Felis, R. Filgas, F. Girard, G. Giroux, A. Grandison , et al. (34 additional authors not shown)

    Abstract: New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays… ▽ More

    Submitted 3 March, 2016; v1 submitted 26 October, 2015; originally announced October 2015.

    Comments: v3 to reflect published version

    Journal ref: Phys. Rev. D 93, 052014 (2016)

  32. arXiv:1509.02910  [pdf

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Conceptual Design Report

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, P. Bauer, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. I. Bolozdynya, E. M. Boulton, R. Bramante, J. H. Buckley, V. V. Bugaev, R. Bunker, S. Burdin, J. K. Busenitz , et al. (170 additional authors not shown)

    Abstract: The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp… ▽ More

    Submitted 23 September, 2015; v1 submitted 9 September, 2015; originally announced September 2015.

    Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors

    Report number: LBNL-190005

  33. arXiv:1503.00008  [pdf, other

    astro-ph.CO physics.ins-det

    Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, S. Daley, M. Das, F. Debris, N. Dhungana, J. Farine, I. Felis, R. Filgas, M. Fines-Neuschild, F. Girard, G. Giroux , et al. (32 additional authors not shown)

    Abstract: New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation o… ▽ More

    Submitted 29 June, 2015; v1 submitted 27 February, 2015; originally announced March 2015.

    Comments: 6 pages, 6 figures, v2 to match published version

    Journal ref: Phys. Rev. Lett. 114, 231302 (2015)

  34. arXiv:1304.6001  [pdf, other

    physics.ins-det astro-ph.CO hep-ex

    Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber

    Authors: COUPP Collaboration, E. Behnke, T. Benjamin, S. J. Brice, D. Broemmelsiek, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, D. Fustin, J. Hall, C. Harnish, I. Levine, W. H. Lippincott, T. Moan, T. Nania, R. Neilson, E. Ramberg, A. E. Robinson, A. Sonnenschein, E. Vázquez-Jáuregui, R. A. Rivera, L. Uplegger

    Abstract: We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel… ▽ More

    Submitted 31 January, 2014; v1 submitted 22 April, 2013; originally announced April 2013.

    Comments: 5 pages, 3 figures

    Report number: FERMILAB-PUB-10-318-A-CD-E

    Journal ref: Phys. Rev. D 88, 021102 (2013)

  35. arXiv:1207.3665  [pdf, other

    physics.ins-det astro-ph.IM

    The LUX Prototype Detector: Heat Exchanger Development

    Authors: D. S. Akerib, X. Bai, S. Bedikian, A. Bernstein, A. Bolozdynya, A. Bradley, S. Cahn, D. Carr, J. J. Chapman, K. Clark, T. Classen, A. Curioni, C. E. Dahl, S. Dazeley, L. deViveiros, M. Dragowsky, E. Druszkiewicz, S. Fiorucci, R. J. Gaitskell, C. Hall, C. Faham, B. Holbrook, L. Kastens, K. Kazkaz, J. Kwong , et al. (25 additional authors not shown)

    Abstract: The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for ac… ▽ More

    Submitted 20 January, 2013; v1 submitted 16 July, 2012; originally announced July 2012.

    Comments: 12 pages, 9 figures

  36. arXiv:0807.0459  [pdf, other

    astro-ph physics.ins-det

    The scintillation and ionization yield of liquid xenon for nuclear recoils

    Authors: P. Sorensen, A. Manzur, C. E. Dahl, J. Angle, E. Aprile, F. Arneodo, L. Baudis, A. Bernstein, A. Bolozdynya, P. Brusov, L. C. C. Coelho, L. DeViveiros, A. D. Ferella, L. M. P. Fernandes, S. Fiorucci, R. J. Gaitskell, K. L. Giboni, R. Gomez, R. Hasty, L. Kastens, J. Kwong, J. A. M. Lopes, N. Madden, A. Manalaysay, D. N. McKinsey , et al. (12 additional authors not shown)

    Abstract: XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relati… ▽ More

    Submitted 30 December, 2008; v1 submitted 3 July, 2008; originally announced July 2008.

    Comments: 8 pages, 9 figures. To be published in Nucl. Instrum. Methods A

    Journal ref: Nucl.Instrum.Meth.A601:339-346,2009

  37. arXiv:astro-ph/0608137  [pdf, ps, other

    astro-ph physics.ins-det

    Performance and Fundamental Processes at Low Energy in a Two-Phase Liquid Xenon Dark Matter Detector

    Authors: T. Shutt, C. E. Dahl, J. Kwong, A. Bolozdynya, P. Brusov

    Abstract: We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated sum of charge and light signals and introduce the corresponding discrimination parameter, giving its mean value at 4 kV/cm for electron and nuclear recoils u… ▽ More

    Submitted 29 September, 2006; v1 submitted 6 August, 2006; originally announced August 2006.

    Comments: 4 pages, 6 figures, submitted to DM06 conference proceedings in Nucl Phys B

    Journal ref: Nucl.Instrum.Meth.A579:451-453,2007