Double-hit separation and dE/dx resolution of a time projection chamber with GEM readout
Authors:
Yumi Aoki,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Bhattacharya Sankar,
Purba Bhattacharya,
Sudeb Bhattacharya,
Yue Chang,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ulrich Einhaus,
Oleksiy Fedorchuk,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Philippe Gros,
Peter Hayman,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (46 additional authors not shown)
Abstract:
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field…
▽ More
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field at the DESY II Test Beam Facility, which provides an electron beam up to 6 GeV/c. The performance of the readout modules, in particular the spatial point resolution, is determined and compared to earlier tests. New studies are presented with first results on the separation of close-by tracks and the capability of the system to measure the specific energy loss dE/dx. This is complemented by a simulation study on the optimization of the readout granularity to improve particle identification by dE/dx.
△ Less
Submitted 25 November, 2022; v1 submitted 24 May, 2022;
originally announced May 2022.
-
City-Scale Agent-Based Simulators for the Study of Non-Pharmaceutical Interventions in the Context of the COVID-19 Epidemic
Authors:
Shubhada Agrawal,
Siddharth Bhandari,
Anirban Bhattacharjee,
Anand Deo,
Narendra M. Dixit,
Prahladh Harsha,
Sandeep Juneja,
Poonam Kesarwani,
Aditya Krishna Swamy,
Preetam Patil,
Nihesh Rathod,
Ramprasad Saptharishi,
Sharad Shriram,
Piyush Srivastava,
Rajesh Sundaresan,
Nidhin Koshy Vaidhiyan,
Sarath Yasodharan
Abstract:
We highlight the usefulness of city-scale agent-based simulators in studying various non-pharmaceutical interventions to manage an evolving pandemic. We ground our studies in the context of the COVID-19 pandemic and demonstrate the power of the simulator via several exploratory case studies in two metropolises, Bengaluru and Mumbai. Such tools become common-place in any city administration's tool…
▽ More
We highlight the usefulness of city-scale agent-based simulators in studying various non-pharmaceutical interventions to manage an evolving pandemic. We ground our studies in the context of the COVID-19 pandemic and demonstrate the power of the simulator via several exploratory case studies in two metropolises, Bengaluru and Mumbai. Such tools become common-place in any city administration's tool kit in our march towards digital health.
△ Less
Submitted 11 August, 2020;
originally announced August 2020.
-
A Time Projection Chamber with GEM-Based Readout
Authors:
The LCTPC Collaboration,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Sankar Bhattacharya,
Purba Bhattacharya,
Sudeb Bhattacharya,
Stefano Caiazza,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Yuanning Gao,
Philippe Gros,
Peter Hayman,
Vincent Hedberg,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (45 additional authors not shown)
Abstract:
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a…
▽ More
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
△ Less
Submitted 4 April, 2016;
originally announced April 2016.
-
Autothermal Reforming of Methane on Rhodium Catalysts: Microkinetic Analysis for Model Reduction
Authors:
Marm Dixit,
Renika Baruah,
Dhrupad Parikh,
Sudhanshu Sharma,
Atul Bhargav
Abstract:
Methane autothermal reforming has been studied using comprehensive, detailed microkinetic mechanisms, and a hierarchically reduced rate expression has been derived without apriori assumptions. The microkinetic mechanism is adapted from literature and has been validated with reported experimental results. Rate Determining Steps are elicited by reaction path analysis, partial equilibrium analysis an…
▽ More
Methane autothermal reforming has been studied using comprehensive, detailed microkinetic mechanisms, and a hierarchically reduced rate expression has been derived without apriori assumptions. The microkinetic mechanism is adapted from literature and has been validated with reported experimental results. Rate Determining Steps are elicited by reaction path analysis, partial equilibrium analysis and sensitivity analysis. Results show that methane activation occurs via dissociative adsorption to pyrolysis, while oxidation of the carbon occurs by O(s). Further, the mechanism is reduced through information obtained from the reaction path analysis, which is further substantiated by principal component analysis. A 33% reduction from the full microkinetic mechanism is obtained. One-step rate equation is further derived from the reduced microkinetic mechanism. The results show that the this rate equation accurately predicts conversions as well as outlet mole fraction for a wide range of inlet compositions.
△ Less
Submitted 25 January, 2016;
originally announced January 2016.
-
Thermodynamics of site-specific small molecular ion interactions with DNA duplex: a molecular dynamics study
Authors:
Soumadwip Ghosh,
Mayank Kumar Dixit,
Rajarshi Chakrabarti
Abstract:
The stability and dynamics of a double-stranded DNA (dsDNA) is affected by the preferential occupancy of small monovalent molecular ions. Small metal and molecular ions such as sodium and alkyl ammonium have crucial biological functions in human body, affect the thermodynamic stability of the duplex DNA and exhibit preferential binding. Here, using atomistic molecular dynamics simulations we inves…
▽ More
The stability and dynamics of a double-stranded DNA (dsDNA) is affected by the preferential occupancy of small monovalent molecular ions. Small metal and molecular ions such as sodium and alkyl ammonium have crucial biological functions in human body, affect the thermodynamic stability of the duplex DNA and exhibit preferential binding. Here, using atomistic molecular dynamics simulations we investigate the preferential binding of metal ion such as Na+ and molecular ions such as tetramethyl ammonium (TMA+) and 2-hydroxy-N,N,N-trimethylethanaminium (CHO+) to double stranded DNA. The thermodynamic driving force for a particular molecular ion- DNA interaction is determined by decomposing the free energy of binding into its entropic and enthalpic contributions. Our simulations show that each of these molecular ions preferentially binds to the minor groove of the DNA and the extent of binding is highest for CHO+. The ion binding processes are found to be entropically favourable. In addition, the contribution of hydrophobic effects towards the entropic stabilization (in case of TMA+) and the effect of hydrogen bonding contributing to enthalpic stabilization (in case of CHO+) have also been investigated.
△ Less
Submitted 21 August, 2015;
originally announced August 2015.
-
Xenon purity analysis for EXO-200 via mass spectrometry
Authors:
A. Dobi,
C. Hall,
S. Slutsky,
Y. -R. Yen,
B. Aharmin,
M. Auger,
P. S. Barbeau,
C. Benitez-Medina,
M. Breidenbach,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
I. Counts,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
M. Dixit,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (51 additional authors not shown)
Abstract:
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We ha…
▽ More
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
△ Less
Submitted 5 September, 2011;
originally announced September 2011.
-
A magnetically-driven piston pump for ultra-clean applications
Authors:
F. LePort,
R. Neilson,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
I. Counts,
J. Davis,
R. deVoe,
M. J. Dolinski,
G. Gratta,
M. Green,
M. Montero Díez,
A. R. Müller,
K. O'Sullivan,
A. Rivas,
K. Twelker,
B. Aharmim,
M. Auger,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
J. Cook
, et al. (55 additional authors not shown)
Abstract:
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute (SL…
▽ More
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.
△ Less
Submitted 26 April, 2011;
originally announced April 2011.
-
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
Authors:
D. S. Leonard,
P. Grinberg,
P. Weber,
E. Baussan,
Z. Djurcic,
G. Keefer,
A. Piepke,
A. Pocar,
J. -L. Vuilleumier,
J. -M. Vuilleumier,
D. Akimov,
A. Bellerive,
M. Bowcock,
M. Breidenbach,
A. Burenkov,
R. Conley,
W. Craddock,
M. Danilov,
R. DeVoe,
M. Dixit,
A. Dolgolenko,
I. Ekchtout,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (32 additional authors not shown)
Abstract:
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma…
▽ More
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.
△ Less
Submitted 4 August, 2008; v1 submitted 28 September, 2007;
originally announced September 2007.
-
Electrically controlled Bragg resonances of an ambichiral electro-optic structure: oblique incidence
Authors:
Mukul Dixit,
Akhlesh Lakhtakia
Abstract:
The Pockels effect can increase the effective birefringence of ambichiral, electro--optic rejection filters made of materials with a $\bar{4}2m$ point group symmetry, when a dc electric field is applied parallel to the axis of nonhomogeneity. The reflectances and the transmittances of such an ambichiral structure for obliquely incident plane waves is solvable through a boundary-value problem tha…
▽ More
The Pockels effect can increase the effective birefringence of ambichiral, electro--optic rejection filters made of materials with a $\bar{4}2m$ point group symmetry, when a dc electric field is applied parallel to the axis of nonhomogeneity. The reflectances and the transmittances of such an ambichiral structure for obliquely incident plane waves is solvable through a boundary-value problem that is formulated using the frequency-domain Maxwell equations, the constitutive equations that contain the Pockels effect, and standard algebraic techniques for handling 4x4 matrix ordinary differential equations. The Bragg resonance peaks, for different circular-polarized-incidence conditions, blueshift as the angle of incidence increases. These blueshifts are unaffected by the sign of the dc electric field.
△ Less
Submitted 12 August, 2007;
originally announced August 2007.
-
Micromegas TPC studies at high magnetic fields using the charge dispersion signal
Authors:
M. Dixit,
D. Attie,
A. Bellerive,
K. Boudjemline,
P. Colas,
P. Giganon,
I. Giomataris,
V. Lepeltier,
S. Liu,
J. -P. Martin,
K. Sachs,
Y. Shin,
S. Turnbull
Abstract:
The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The ne…
▽ More
The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The new MPGD readout technique of charge dispersion can achieve good resolution without resorting to narrow pads. This has been demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmic ray tests and in a KEK beam test in a 1 Tesla magnet. We have recently tested a Micromegas-TPC using the charge dispersion readout concept in a high field super-conducting magnet at DESY. The measured Micromegas gain was found to be constant within 0.5% for magnetic fields up to 5 Tesla. With the strong suppression of transverse diffusion at high magnetic fields, we measure a flat 50 micron resolution at 5 Tesla over the full 15 cm drift length of our prototype TPC.
△ Less
Submitted 28 March, 2007;
originally announced March 2007.
-
Spatial resolution of a GEM readout TPC using the charge dispersion signal
Authors:
K. Boudjemline,
M. S. Dixit,
J. -P. Martin,
K. Sachs
Abstract:
A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100 microns with a manageable number of readout pads and channels of electronics, Micro Pattern Gas Detectors (MPGD) are being developed which could use pads comparable…
▽ More
A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100 microns with a manageable number of readout pads and channels of electronics, Micro Pattern Gas Detectors (MPGD) are being developed which could use pads comparable in width to the proportional-wire/cathode-pad TPC. We have built a prototype GEM readout TPC with 2 mm x 6 mm pads using the new concept of charge dispersion in MPGDs with a resistive anode. The dependence of transverse resolution on the drift distance has been measured for small angle tracks in cosmic ray tests without a magnetic field for Ar/CO2 (90:10). The GEM-TPC resolution with charge dispersion readout is significantly better than previous measurements carried out with conventional direct charge readout techniques.
△ Less
Submitted 26 October, 2006;
originally announced October 2006.
-
Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode
Authors:
M. S. Dixit,
A. Rankin
Abstract:
The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode pad TPC and Micro-Pattern Gas Detectors (MPGD) are being developed to meet the challenge. The standard MPGD readout techniques will, however, have difficulty in…
▽ More
The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode pad TPC and Micro-Pattern Gas Detectors (MPGD) are being developed to meet the challenge. The standard MPGD readout techniques will, however, have difficulty in achieving the ILC-TPC resolution goal with the 2 mm x 6 mm pads as was initially envisioned. Proposals for smaller width pads will improve the resolution but will require a larger number of readout channels and increase the TPC detector cost and complexity. The new MPGD readout concept of charge dispersion has the potential to achieve the ILC-TPC resolution goal without resorting to narrower pads. This was recently demonstrated in cosmic ray tests of a small prototype TPC read out with MPGDs using the charge dispersion technique. Here we describe the simulation of the charge dispersion phenomena for the MPGD-TPC. The detailed simulation includes initial ionization clustering, electron drift, diffusion effects, the intrinsic detector pulse-shape and electronics effects. The simulation is in excellent agreement with the experimental data and can be used to optimize the MPGD charge dispersion readout for the TPC.
△ Less
Submitted 15 May, 2006;
originally announced May 2006.
-
Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal
Authors:
A. Bellerive,
K. Boudjemline,
R. Carnegie,
M. Dixit,
J. Miyamoto,
E. Neuheimer,
A. Rankin,
E. Rollin,
K. Sachs,
J. -P. Martin,
V. Lepeltier,
P. Colas,
A. Giganon,
I. Giomataris
Abstract:
The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $μ$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new…
▽ More
The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $μ$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new MPGD readout concept of charge dispersion to a prototype GEM-TPC and demonstrated the feasibility of achieving good resolution with pads similar in width to the ones used for the proportional wire TPC. The charge dispersion studies were repeated with a Micromegas TPC amplification stage. We present here our first results on the Micromegas-TPC resolution with charge dispersion. The TPC resolution with the Micromegas readout is compared to our earlier GEM results and to the resolution expected from electron statistics and transverse diffusion in a gaseous TPC.
△ Less
Submitted 11 October, 2005;
originally announced October 2005.
-
Resolution studies of cosmic-ray tracks in a TPC with GEM readout
Authors:
R. K. Carnegie,
M. S. Dixit,
J. Dubeau,
D. Karlen,
J. -P. Martin,
H. Mes,
K. Sachs
Abstract:
A large volume TPC is a leading candidate for the central tracking detector at a future high energy linear collider. To improve the resolution a new readout based on micro-pattern gas detectors is being developed. Measurements of the spatial resolution of cosmic-ray tracks in a GEM TPC are presented. We find that the resolution suffers if the readout pads are too wide with respect to the charge…
▽ More
A large volume TPC is a leading candidate for the central tracking detector at a future high energy linear collider. To improve the resolution a new readout based on micro-pattern gas detectors is being developed. Measurements of the spatial resolution of cosmic-ray tracks in a GEM TPC are presented. We find that the resolution suffers if the readout pads are too wide with respect to the charge distribution at the readout plane due to insufficient charge sharing. For narrow pads of 2 x 6 mm**2 we measure a resolution of 100 micometer at short drift distances in the absence of an axial magnetic field. The dependence of the spatial resolution as a function of drift distance allows the determination of the underlying electron statistics. Our results show that the present technique uses about half the statistical power available from the number of primary electrons. The track angle effect is observed as expected.
△ Less
Submitted 7 February, 2005; v1 submitted 10 February, 2004;
originally announced February 2004.
-
Position Sensing from Charge Dispersion in Micro-Pattern Gas Detectors with a Resistive Anode
Authors:
M. S. Dixit,
J. Dubeau,
J. -P. Martin,
K. Sachs
Abstract:
Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number of electronics channels for certain potential micro-detector applications such as the Time Projection Chamber. We describe below a new technique to achieve go…
▽ More
Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number of electronics channels for certain potential micro-detector applications such as the Time Projection Chamber. We describe below a new technique to achieve good spatial resolution without increasing the electronics channel count in a modified micro-detector outfitted with a high surface resistivity anode readout structure. The concept and preliminary measurements of spatial resolution from charge dispersion in a modified GEM detector with a resistive anode are described below.
△ Less
Submitted 31 October, 2003; v1 submitted 30 July, 2003;
originally announced July 2003.