Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–12 of 12 results for author: Martin, J -

Searching in archive physics. Search in all archives.
.
  1. arXiv:2107.06007  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The EXO-200 detector, part II: Auxiliary Systems

    Authors: N. Ackerman, J. Albert, M. Auger, D. J. Auty, I. Badhrees, P. S. Barbeau, L. Bartoszek, E. Baussan, V. Belov, C. Benitez-Medina, T. Bhatta, M. Breidenbach, T. Brunner, G. F. Cao, W. R. Cen, C. Chambers, B. Cleveland, R. Conley, S. Cook, M. Coon, W. Craddock, A. Craycraft, W. Cree, T. Daniels, L. Darroch , et al. (135 additional authors not shown)

    Abstract: The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op… ▽ More

    Submitted 22 October, 2021; v1 submitted 13 July, 2021; originally announced July 2021.

    Comments: Manuscript updated in response to JINST reviewer comments

  2. The GRIFFIN Data Acquisition System

    Authors: A. B. Garnsworthy, C. J. Pearson, D. Bishop, B. Shaw, J. K. Smith, M. Bowry, V. Bildstein, G. Hackman, P. E. Garrett, Y. Linn, J. -P. Martin, W. J. Mills, C. E. Svensson

    Abstract: Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. This article describes the details of the custom designed GRIFFIN digital data acquisition system. The features of the system that will enable high-precision half-life and branching ratio measurements with levels of uncertainty bett… ▽ More

    Submitted 16 November, 2017; originally announced November 2017.

  3. arXiv:1611.01499  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Final Results of the PICASSO Dark Matter Search Experiment

    Authors: E. Behnke, M. Besnier, P. Bhattacharjee, X. Dai, M. Das, A. Davour, F. Debris, N. Dhungana, J. Farine, M. Fines-Neuschild, S. Gagnebin, G. Giroux, E. Grace, C. M. Jackson, A. Kamaha, C. B. Krauss, M. Lafrenière, M. Laurin, I. Lawson, L. Lessard, I. Levine, D. Marlisov, J. -P. Martin, P. Mitra, A. J. Noble , et al. (9 additional authors not shown)

    Abstract: The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the final results of this experiment which includes for the first time the complete data set and improved analysis techniques including \mbox{acoustic} localization to… ▽ More

    Submitted 23 March, 2017; v1 submitted 4 November, 2016; originally announced November 2016.

    Comments: 24 pages, 7 figures

    Journal ref: Astropart. Phys. 90, 85-92 (2017)

  4. arXiv:1306.5655  [pdf, other

    physics.ins-det hep-ex

    SuperB Technical Design Report

    Authors: SuperB Collaboration, M. Baszczyk, P. Dorosz, J. Kolodziej, W. Kucewicz, M. Sapor, A. Jeremie, E. Grauges Pous, G. E. Bruno, G. De Robertis, D. Diacono, G. Donvito, P. Fusco, F. Gargano, F. Giordano, F. Loddo, F. Loparco, G. P. Maggi, V. Manzari, M. N. Mazziotta, E. Nappi, A. Palano, B. Santeramo, I. Sgura, L. Silvestris , et al. (384 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch… ▽ More

    Submitted 24 June, 2013; originally announced June 2013.

    Comments: 495 pages

    Report number: INFN-13-01/PI, LAL 13-01, SLAC-R-1003

  5. arXiv:1011.4553  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    New Insights into Particle Detection with Superheated Liquids

    Authors: S. Archambault, F. Aubin, M. Auger, M. Beleshi, E. Behnke, J. Behnke, B. Beltran, K. Clark, X. Dai, A. Davour, F. Debris. J. Farine, M. -H. Genest, G. Giroux, R. Gornea, R. Faust, H. Hinnefeld, A. Kamaha, C. B. Krauss, M. Lafrenière, M. Laurin, I. Lawson, C. Leroy, C. Lévy, L. Lessard, I. Levine , et al. (12 additional authors not shown)

    Abstract: We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$α$,$γ$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy threshold… ▽ More

    Submitted 20 November, 2010; originally announced November 2010.

    Journal ref: New J.Phys.13:043006,2011

  6. arXiv:0807.1536  [pdf, ps, other

    physics.ins-det hep-ex

    Discrimination of nuclear recoils from alpha particles with superheated liquids

    Authors: F. Aubin, M. Auger, E. Behnke, B. Beltran, K. Clark, X. Dai, A. Davour, M. -H. Genest, G. Giroux, R. Gornea, R. Faust, C. B. Krauss, C. Leroy, L. Lessard, I. Levine, C. Levy, J. -P. Martin, T. Morlat, A. J. Noble, P. Nadeau, M. -C. Piro, S. Pospisil, T. Shepherd, J. Sodomka, N. Starinski , et al. (4 additional authors not shown)

    Abstract: The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved background suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubble… ▽ More

    Submitted 23 September, 2008; v1 submitted 10 July, 2008; originally announced July 2008.

    Comments: 7 pages, 4 figures. accepted for publication in New Journal of Physics

    Journal ref: NewJ.Phys.10:103017,2008

  7. Micromegas TPC studies at high magnetic fields using the charge dispersion signal

    Authors: M. Dixit, D. Attie, A. Bellerive, K. Boudjemline, P. Colas, P. Giganon, I. Giomataris, V. Lepeltier, S. Liu, J. -P. Martin, K. Sachs, Y. Shin, S. Turnbull

    Abstract: The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The ne… ▽ More

    Submitted 28 March, 2007; originally announced March 2007.

    Comments: 7 pages, 3 figures

    Journal ref: Nucl.Instrum.Meth.A581:254-257,2007

  8. Spatial resolution of a GEM readout TPC using the charge dispersion signal

    Authors: K. Boudjemline, M. S. Dixit, J. -P. Martin, K. Sachs

    Abstract: A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100 microns with a manageable number of readout pads and channels of electronics, Micro Pattern Gas Detectors (MPGD) are being developed which could use pads comparable… ▽ More

    Submitted 26 October, 2006; originally announced October 2006.

    Comments: 5 figures, 10 pages

    Report number: Carleton Phys/061020

    Journal ref: Nucl.Instrum.Meth.A574:22-27,2007

  9. arXiv:physics/0510085  [pdf, ps, other

    physics.ins-det

    Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

    Authors: A. Bellerive, K. Boudjemline, R. Carnegie, M. Dixit, J. Miyamoto, E. Neuheimer, A. Rankin, E. Rollin, K. Sachs, J. -P. Martin, V. Lepeltier, P. Colas, A. Giganon, I. Giomataris

    Abstract: The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $μ$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new… ▽ More

    Submitted 11 October, 2005; originally announced October 2005.

    Comments: 5 pages, 8 figures, to appar in the Proceedings of the 2005 International Linear Collider Workshop (LCWS05), Stanford, 18-22 March 2005

    Report number: Carleton Phys0508, DAPNIA 05-232, LAL 05-99

  10. Response of Superheated Droplet Detectors of the PICASSO Dark Matter Search Experiment

    Authors: The PICASSO Collaboration, M. Barnabe-Heider, E. Behnke, K. Clark, M. Di Marco, P. Doane, W. Feighery, M. -H. Genest, R. Gornea, R. Guenette, S. Kanagalingam, C. B. Krauss, C. Leroy, L. Lessard, I. Levine, J. -P. Martin, C. Muthusi, A. J. Noble, R. Noulty, U. Wichoski, V. Zacek

    Abstract: We present results of systematic studies of the radiation response of superheated liquid droplet detectors, which are used in the PICASSO dark matter search experiment. This detection technique is based on the phase transitions of superheated liquid Freon droplets dispersed and trapped in a polymerized gel. Phase transitions can be induced by nuclear recoils following particle interactions and,… ▽ More

    Submitted 15 August, 2005; originally announced August 2005.

    Comments: 70 pages, 33 low resolution figures; higher resolution figures available at http://picassoweb.lps.umontreal.ca/ . Submitted to NIM A

    Journal ref: Nucl.Instrum.Meth. A555 (2005) 184-204

  11. Resolution studies of cosmic-ray tracks in a TPC with GEM readout

    Authors: R. K. Carnegie, M. S. Dixit, J. Dubeau, D. Karlen, J. -P. Martin, H. Mes, K. Sachs

    Abstract: A large volume TPC is a leading candidate for the central tracking detector at a future high energy linear collider. To improve the resolution a new readout based on micro-pattern gas detectors is being developed. Measurements of the spatial resolution of cosmic-ray tracks in a GEM TPC are presented. We find that the resolution suffers if the readout pads are too wide with respect to the charge… ▽ More

    Submitted 7 February, 2005; v1 submitted 10 February, 2004; originally announced February 2004.

    Comments: 18 pages, 8 figures, version as published in Nucl. Inst. Meth

    Report number: LC-DET-2004-004

    Journal ref: Nucl.Instrum.Meth.A538:372-383,2005

  12. Position Sensing from Charge Dispersion in Micro-Pattern Gas Detectors with a Resistive Anode

    Authors: M. S. Dixit, J. Dubeau, J. -P. Martin, K. Sachs

    Abstract: Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number of electronics channels for certain potential micro-detector applications such as the Time Projection Chamber. We describe below a new technique to achieve go… ▽ More

    Submitted 31 October, 2003; v1 submitted 30 July, 2003; originally announced July 2003.

    Comments: 14 pages, 8 figures, submitted to Nucl. Inst. Meth; typo in eqn 4 corrected, fig 2 updated accordingly

    Journal ref: Nucl.Instrum.Meth.A518:721-727,2004