-
Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $α$-Particles in Liquid Argon using DEAP-3600 Data
Authors:
The DEAP Collaboration,
P. Adhikari,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
D. J. Auty,
M. Batygov,
B. Beltran,
C. E. Bina,
W. Bonivento,
M. G. Boulay,
J. F. Bueno,
B. Cai,
M. Cárdenas-Montes,
S. Choudhary,
B. T. Cleveland,
R. Crampton,
S. Daugherty,
P. DelGobbo,
P. Di Stefano,
G. Dolganov,
L. Doria,
F. A. Duncan,
M. Dunford,
E. Ellingwood
, et al. (73 additional authors not shown)
Abstract:
The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace…
▽ More
The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace amounts in the DEAP-3600 detector and quantified the uncertainty of extrapolating the quenching factor to the low-energy region.
△ Less
Submitted 12 June, 2024;
originally announced June 2024.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
Authors:
The DEAP Collaboration,
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
D. J. Auty,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
J. M. Corning
, et al. (104 additional authors not shown)
Abstract:
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar…
▽ More
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors.
The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.
△ Less
Submitted 6 April, 2021; v1 submitted 22 March, 2021;
originally announced March 2021.
-
The liquid-argon scintillation pulseshape in DEAP-3600
Authors:
The DEAP collaboration,
P. Adhikari,
R. Ajaj,
G. R. Araujoand M. Batygov,
B. Beltran,
C. E. Bina,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. J. Daughertyand K. Dering,
L. Doria,
F. A. Duncan andM. Dunford,
A. Erlandson,
N. Fatemighomi,
G. Fiorillo,
A. Flower,
R. J. Ford,
R. Gagnon
, et al. (76 additional authors not shown)
Abstract:
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed…
▽ More
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed here is the basis of PSD.
The observed pulseshape is a combination of LAr scintillation physics with detector effects. We present a model for the pulseshape of electromagnetic background events in the energy region of interest for dark matter searches. The model is composed of a) LAr scintillation physics, including the so-called intermediate component, b) the time response of the TPB wavelength shifter, including delayed TPB emission at $\mathcal O$(ms) time-scales, and c) PMT response.
TPB is the wavelength shifter of choice in most LAr detectors. We find that approximately 10\% of the intensity of the wavelength-shifted light is in a long-lived state of TPB. This causes light from an event to spill into subsequent events to an extent not usually accounted for in the design and data analysis of LAr-based detectors.
△ Less
Submitted 8 June, 2020; v1 submitted 27 January, 2020;
originally announced January 2020.
-
In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment
Authors:
DEAP Collaboration,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
S. Churchwell,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
S. Dittmeier,
F. A. Duncan,
M. Dunford,
A. Erlandson
, et al. (77 additional authors not shown)
Abstract:
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed.
We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detaile…
▽ More
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed.
We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.
△ Less
Submitted 29 January, 2019; v1 submitted 29 May, 2017;
originally announced May 2017.
-
The search for neutron-antineutron oscillations at the Sudbury Neutrino Observatory
Authors:
SNO Collaboration,
B. Aharmim,
S. N. Ahmed,
A. E. Anthony,
N. Barros,
E. W. Beier,
A. Bellerive,
B. Beltran,
M. Bergevin,
S. D. Biller,
K. Boudjemline,
M. G. Boulay,
B. Cai,
Y. D. Chan,
D. Chauhan,
M. Chen,
B. T. Cleveland,
G. A. Cox,
X. Dai,
H. Deng,
J. A. Detwiler,
P. J. Doe,
G. Doucas,
P. -L. Drouin,
F. A. Duncan
, et al. (100 additional authors not shown)
Abstract:
Tests on $B-L$ symmetry breaking models are important probes to search for new physics. One proposed model with $Δ(B-L)=2$ involves the oscillations of a neutron to an antineutron. In this paper a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search was concentrated in oscillations occurring within t…
▽ More
Tests on $B-L$ symmetry breaking models are important probes to search for new physics. One proposed model with $Δ(B-L)=2$ involves the oscillations of a neutron to an antineutron. In this paper a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search was concentrated in oscillations occurring within the deuteron, and 23 events are observed against a background expectation of 30.5 events. These translate to a lower limit on the nuclear lifetime of $1.48\times 10^{31}$ years at 90% confidence level (CL) when no restriction is placed on the signal likelihood space (unbounded). Alternatively, a lower limit on the nuclear lifetime was found to be $1.18\times 10^{31}$ years at 90% CL when the signal was forced into a positive likelihood space (bounded). Values for the free oscillation time derived from various models are also provided in this article. This is the first search for neutron-antineutron oscillation with the deuteron as a target.
△ Less
Submitted 1 May, 2017;
originally announced May 2017.
-
Considerations on Interdisciplinary Instruction and Design Influenced by Adaptive Learning. A Case Study Involving Biology, Computer Science, Mathematics, and Statistics
Authors:
Karen Aguar,
Charles C. Sanchez,
Diego Boada Beltran,
Saeid Safaei,
Mehdi Asefi,
Jonathan Arnold,
Pedro Portes,
Hamid R. Arabnia,
Juan B. Gutierrez
Abstract:
ALICE (Adaptive Learning for Interdisciplinary Collaborative Environments) is an open-source web based adaptive learning system designed for interdisciplinary instruction. ALICE has the potential to transform education by empowering transdisciplinary knowledge acquisition. This is particularly important in fields that accept newcomers with diverse scholastic backgrounds, e.g. Systems Biology. With…
▽ More
ALICE (Adaptive Learning for Interdisciplinary Collaborative Environments) is an open-source web based adaptive learning system designed for interdisciplinary instruction. ALICE has the potential to transform education by empowering transdisciplinary knowledge acquisition. This is particularly important in fields that accept newcomers with diverse scholastic backgrounds, e.g. Systems Biology. With traditional interdisciplinary instruction, the instructor must cover pre-requisite information from multiple disciplines to ensure all students begin at a common baseline - slowing the learning process. With ALICE, students follow a personalized syllabus based on their previous knowledge and work towards individual goals. Implementing an adaptive learning system in an interdisciplinary course requires careful considerations of the instructional design. Structuring material, formulating assessments, and other instructional design aspects must be carefully considered. These considerations are detailed through the exploration of a case study implementing ALICE in a graduate level Systems Biology course.
△ Less
Submitted 4 May, 2017; v1 submitted 17 March, 2017;
originally announced March 2017.
-
DEAP-3600 Dark Matter Search
Authors:
DEAP Collaboration,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
J. Bonatt,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Chen,
R. Chouinard,
B. T. Cleveland,
K. Dering,
J. DiGioseffo,
F. Duncan,
T. Flower,
R. Ford,
P. Giampa,
P. Gorel,
K. Graham,
D. R. Grant,
E. Guliyev,
A. L. Hallin,
M. Hamstra
, et al. (32 additional authors not shown)
Abstract:
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds…
▽ More
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds and helped to develop low radioactivity techniques to mitigate surface-related $α$ backgrounds. Construction of the DEAP-3600 detector is nearly complete and commissioning is starting in 2014. The target sensitivity to spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons of 10$^{-46}$ cm$^2$ will allow one order of magnitude improvement in sensitivity over current searches at 100 GeV WIMP mass. This paper presents an overview and status of the DEAP-3600 project and discusses plans for a future multi-tonne experiment, DEAP-50T.
△ Less
Submitted 25 August, 2015; v1 submitted 27 October, 2014;
originally announced October 2014.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Authors:
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
K. Boudjemline,
M. G. Boulay B. Cai T. Caldwell,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Contreras,
K. Dering,
F. Duncan,
R. Ford,
R. Gagnon F. Giuliani,
M. Gold V. V. Golovko,
P. Gorel,
K. Graham,
D. R. Grant,
R. Hakobyan,
A. L. Hallin,
P. Harvey,
C. Hearns,
C. J. Jillings,
M. Kuźniak,
I. Lawson,
O. Li
, et al. (27 additional authors not shown)
Abstract:
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.…
▽ More
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.
△ Less
Submitted 23 April, 2014; v1 submitted 5 November, 2012;
originally announced November 2012.
-
A Monte Carlo simulation of the Sudbury Neutrino Observatory proportional counters
Authors:
B. Beltran,
H. Bichsel,
B. Cai,
H. Deng,
J. A. Formaggio,
S. Habib,
A. L. Hallin,
A. Hime,
M. Huang,
C. Kraus,
H. R. Leslie,
J. C. Loach,
R. Martin,
S. McGee,
M. L. Miller,
B. Monreal,
J. Monroe,
N. S. Oblath,
S. J. M. Peeters,
A. W. P. Poon,
G. Prior,
K. Rielage,
R. G. H. Robertson,
M. W. E. Smith,
L. C. Stonehill
, et al. (6 additional authors not shown)
Abstract:
The third phase of the Sudbury Neutrino Observatory (SNO) experiment added an array of 3He proportional counters to the detector. The purpose of this Neutral Current Detection (NCD) array was to observe neutrons resulting from neutral-current solar neutrino-deuteron interactions. We have developed a detailed simulation of the current pulses from the NCD array proportional counters, from the primar…
▽ More
The third phase of the Sudbury Neutrino Observatory (SNO) experiment added an array of 3He proportional counters to the detector. The purpose of this Neutral Current Detection (NCD) array was to observe neutrons resulting from neutral-current solar neutrino-deuteron interactions. We have developed a detailed simulation of the current pulses from the NCD array proportional counters, from the primary neutron capture on 3He through the NCD array signal-processing electronics. This NCD array Monte Carlo simulation was used to model the alpha-decay background in SNO's third-phase 8B solar-neutrino measurement.
△ Less
Submitted 13 April, 2011;
originally announced April 2011.
-
New Insights into Particle Detection with Superheated Liquids
Authors:
S. Archambault,
F. Aubin,
M. Auger,
M. Beleshi,
E. Behnke,
J. Behnke,
B. Beltran,
K. Clark,
X. Dai,
A. Davour,
F. Debris. J. Farine,
M. -H. Genest,
G. Giroux,
R. Gornea,
R. Faust,
H. Hinnefeld,
A. Kamaha,
C. B. Krauss,
M. Lafrenière,
M. Laurin,
I. Lawson,
C. Leroy,
C. Lévy,
L. Lessard,
I. Levine
, et al. (12 additional authors not shown)
Abstract:
We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$α$,$γ$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy threshold…
▽ More
We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$α$,$γ$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy thresholds for $α$-emitters are compared with test beam measurements using mono-energetic neutrons, as well as with theoretical predictions. Finally a model is presented which describes how the observed intensities of particle induced acoustic signals can be related to the dynamics of bubble growth in superheated liquids. An improved understanding of the bubble dynamics is an important first step in obtaining better discrimination between particle types interacting in detectors of this kind.
△ Less
Submitted 20 November, 2010;
originally announced November 2010.
-
Discrimination of nuclear recoils from alpha particles with superheated liquids
Authors:
F. Aubin,
M. Auger,
E. Behnke,
B. Beltran,
K. Clark,
X. Dai,
A. Davour,
M. -H. Genest,
G. Giroux,
R. Gornea,
R. Faust,
C. B. Krauss,
C. Leroy,
L. Lessard,
I. Levine,
C. Levy,
J. -P. Martin,
T. Morlat,
A. J. Noble,
P. Nadeau,
M. -C. Piro,
S. Pospisil,
T. Shepherd,
J. Sodomka,
N. Starinski
, et al. (4 additional authors not shown)
Abstract:
The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved background suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubble…
▽ More
The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved background suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubbles on alpha tracks, compared to single nucleations created by neutron induced recoils.
△ Less
Submitted 23 September, 2008; v1 submitted 10 July, 2008;
originally announced July 2008.
-
Background study for the pn-CCD detector of CERN Axion Solar Telescope
Authors:
S. Cebrián,
A. Rodríguez,
M. Kuster,
B. Beltrán,
J. M. Carmona,
H. Gómez,
R. Hartmann,
I. G. Irastorza,
R. Kotthaus,
G. Luzón,
J. Morales,
A. Ortiz de Solórzano,
J. Ruz,
L. Strüder,
J. A. Villar
Abstract:
The CERN Axion Solar Telescope (CAST) experiment searches for axions from the Sun converted into photons with energies up to around 10 keV via the inverse Primakoff effect in the high magnetic field of a superconducting Large Hadron Collider (LHC) prototype magnet. A backside illuminated pn-CCD detector in conjunction with an X-ray mirror optics is one of the three detectors used in CAST to regi…
▽ More
The CERN Axion Solar Telescope (CAST) experiment searches for axions from the Sun converted into photons with energies up to around 10 keV via the inverse Primakoff effect in the high magnetic field of a superconducting Large Hadron Collider (LHC) prototype magnet. A backside illuminated pn-CCD detector in conjunction with an X-ray mirror optics is one of the three detectors used in CAST to register the expected photon signal. Since this signal is very rare and different background components (environmental gamma radiation, cosmic rays, intrinsic radioactive impurities in the set-up, ...) entangle it, a detailed study of the detector background has been undertaken with the aim to understand and further reduce the background level of the detector. The analysis is based on measured data taken during the Phase I of CAST and on Monte Carlo simulations of different background components. This study will show that the observed background level (at a rate of (8.00+-0.07)10^-5 counts/cm^2/s/keV between 1 and 7 keV) seems to be dominated by the external gamma background due to usual activities at the experimental site, while radioactive impurities in the detector itself and cosmic neutrons could make just smaller contribution.
△ Less
Submitted 23 April, 2007;
originally announced April 2007.
-
The CAST Time Projection Chamber
Authors:
D. Autiero,
B. Beltran,
J. M. Carmona,
S. Cébrian,
E. Chesi,
M. Davenport,
M. Delattre,
L. Di Lella,
F. Formenti,
I. G. Irastorza,
H. Gomez,
M. Hasinoff,
B. Lakić,
G. Luzón,
J. Morales,
L. Musa,
A. Ortiz,
A. Placci,
A. Rodriguez,
J. Ruz,
J. A. Villar,
K. Zioutas
Abstract:
One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high sensitivity to the detection of the low intensity X-ray signal expected in the CAST experiment. A low hardware threshold of 0.8 keV is safely set during normal data…
▽ More
One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high sensitivity to the detection of the low intensity X-ray signal expected in the CAST experiment. A low hardware threshold of 0.8 keV is safely set during normal data taking periods, and the overall efficiency for the detection of photons coming from conversion of solar axions is 62 %. Shielding has been installed around the detector, lowering the background level to 4.10 x 10^-5 counts/cm^2/s/keV between 1 and 10 keV. During phase I of the CAST experiment the TPC has provided robust and stable operation, thus contributing with a competitive result to the overall CAST limit on axion-photon coupling and mass.
△ Less
Submitted 22 February, 2007;
originally announced February 2007.