BambooMC -- A Geant4-based simulation program for the PandaX experiments
Authors:
Xun Chen,
Chen Cheng,
Mengting Fu,
Franco Giuliani,
Jianglai Liu,
Xiaoying Lu,
Xiangdong Ji,
Zhicheng Qian,
Hao Qiao,
Qiuhong Wang,
Jingkai Xia,
Pengwei Xie,
Yukun Yao,
Hongguang Zhang
Abstract:
The purpose of the PandaX experiments is to search for the possible events resulted from dark matter particles, neutrinoless double beta decay or other rare processes with xenon detectors. Understanding the energy depositions from backgrounds or calibration sources in these detectors is very important. The program of BambooMC is created to perform the Geant4-based Monte Carlo simulation, providing…
▽ More
The purpose of the PandaX experiments is to search for the possible events resulted from dark matter particles, neutrinoless double beta decay or other rare processes with xenon detectors. Understanding the energy depositions from backgrounds or calibration sources in these detectors is very important. The program of BambooMC is created to perform the Geant4-based Monte Carlo simulation, providing reference information for the experiments. We introduce the design and features of BambooMC in this report. The running of the program depends on a configuration file, which combines different detectors, event generators, physics lists and analysis packs together in one simulation. The program can be easily extended and applied to other experiments.
△ Less
Submitted 13 July, 2021;
originally announced July 2021.
-
Calibration Strategy of the JUNO Experiment
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
Thilo Birkenfeld
, et al. (571 additional authors not shown)
Abstract:
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector ca…
▽ More
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination.
△ Less
Submitted 20 January, 2021; v1 submitted 12 November, 2020;
originally announced November 2020.
-
Status and development of the TOP-IMPLART Project
Authors:
L. Picardi,
A. Ampollini,
P. Anello,
M. Balduzzi,
G. Bazzano,
F. Borgognoni,
E. Cisbani,
M. DAndrea,
C. De Angelis,
G. De Angelis,
S. Della Monaca,
G. Esposito,
F. Ghio,
F. Giuliani,
M. Lucentini,
C. Marino,
R. M. Montereali,
P. Nenzi,
C. Notaro,
C. Patrono,
C. Placido,
M. Piccinini,
C. Ronsivalle,
F. Santavenere,
A. Spurio
, et al. (5 additional authors not shown)
Abstract:
The TOP-IMPLART project consists of the design and implementation of a linear proton accelerator, its control and monitoring systems for the treatment of superficial and semi-deep tumors. The energy of 150 MeV (corresponding to a penetration in tissue of about 15 cm) is a milestone in design being useful for the proton therapy treatment of almost 50% of tumors based on their position and depth (in…
▽ More
The TOP-IMPLART project consists of the design and implementation of a linear proton accelerator, its control and monitoring systems for the treatment of superficial and semi-deep tumors. The energy of 150 MeV (corresponding to a penetration in tissue of about 15 cm) is a milestone in design being useful for the proton therapy treatment of almost 50% of tumors based on their position and depth (including ocular melanoma, head-neck tumors, pediatric tumors, and more superficial tumors). The capability to vary the intensity on a pulse-to-pulse basis combined with an electronic feedback system allows to get the required dose uniformity (2.5%) reducing the number of re-paintings. In this paper the state of the art and the objectives of the TOP-IMPLART project are described within the framework of the progress of Protontherapy.
△ Less
Submitted 12 October, 2020;
originally announced October 2020.
-
The Mini-CAPTAIN Liquid Argon Time Projection Chamber
Authors:
CAPTAIN Collaboration,
C. E. Taylor,
B. Bhandari,
J. Bian,
K. Bilton,
C. Callahan,
J. Chaves,
H. Chen,
D. Cline,
R. L. Cooper,
D. L. Danielson,
J. Danielson,
N. Dokania,
S. Elliot,
S. Fernandes,
S. Gardiner,
G. Garvey,
V. Gehman,
F. Giuliani,
S. Glavin,
M. Gold,
C. Grant,
E. Guardincerri,
T. Haines,
A. Higuera
, et al. (51 additional authors not shown)
Abstract:
This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryost…
▽ More
This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (572 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid s…
▽ More
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO's potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.
△ Less
Submitted 21 June, 2020;
originally announced June 2020.
-
TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (568 additional authors not shown)
Abstract:
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future re…
▽ More
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Limited Angle Tomography reconstruction for non-standard MBI system by means of parallel-hole and pinhole optics
Authors:
G. E. Poma,
F. Garibaldi,
F. Giuliani,
T. Insero,
M. Lucentini,
A. Marcucci,
P. Musico,
J. Nuyts,
F. Santavenere,
G. Schramm,
C. Sutera,
E. Cisbani
Abstract:
The purpose of the present work is the study of reconstruction properties of a new Molecular Breast Imaging (MBI) device for the early diagnosis of breast cancer, in Limited Angle Tomography (LAT), by using two asymmetric detector heads with different collimators. The detectors face each other in anti-parallel viewing direction and, mild-compressing the breast phantom, they are able to reconstruct…
▽ More
The purpose of the present work is the study of reconstruction properties of a new Molecular Breast Imaging (MBI) device for the early diagnosis of breast cancer, in Limited Angle Tomography (LAT), by using two asymmetric detector heads with different collimators. The detectors face each other in anti-parallel viewing direction and, mild-compressing the breast phantom, they are able to reconstruct the inner tumour of the phantoms with only a limited number of projections using a dedicated maximum-likelihood expectation maximization (ML-EM) algorithm. Phantoms, MBI system, as well as Monte Carlo simulator using Geant 4 Application for Tomographic Emission (GATE) software, are briefly described. MBI system's model has been implemented in IDL (Interactive Data Visualization), in order to evaluate the best LAT configuration of the system and its reconstruction ability by varying tumour's size, depth and uptake. LAT setup in real and simulated configurations, as well as the ML-EM method and the preliminary reconstruction results, are discussed.
△ Less
Submitted 8 April, 2020; v1 submitted 25 January, 2020;
originally announced January 2020.
-
Development of a high-resolution and high efficiency Single Photon detector for studying cardiovascular diseases in mice
Authors:
F. Garibaldi,
E. Cisbani,
F. Cusanno,
G. De Vincentis,
F. Giuliani,
M. Lucentini,
M. L. Magliozzi,
S. Majewski,
G. Marano,
P. Musico,
F. Santanvenere,
B. M. W. Tsui,
Y. Wang
Abstract:
SPECT systems using pinhole apertures permit radiolabeled molecular distributions to be imaged in vivo in small animals. Nevertheless studying cardiovascular diseases by means of small animal models is very challenging. Specifically, submillimeter spatial resolution, good energy resolution and high sensitivity are required. We designed what we consider the "optimal" radionuclide detector system fo…
▽ More
SPECT systems using pinhole apertures permit radiolabeled molecular distributions to be imaged in vivo in small animals. Nevertheless studying cardiovascular diseases by means of small animal models is very challenging. Specifically, submillimeter spatial resolution, good energy resolution and high sensitivity are required. We designed what we consider the "optimal" radionuclide detector system for this task. It should allow studying both detection of unstable atherosclerotic plaques and monitoring the effect of therapies. Using mice is particularly challenging in situations that require several intravenous injections of radiotracers, possibly for week or even months, in chronically ill animals. Thus, alternative routes of delivering the radiotracer in tail vein should be investigated. In this study we have performed preliminary measurements of detection of atherosclerotic plaques in genetically modified mice with high-resolution prototype detector. We have also evaluated the feasibility of assessing left ventricular perfusion by intraperitoneal delivering of MIBI-Tc in healthy mice.
△ Less
Submitted 19 October, 2019;
originally announced October 2019.
-
An Improved Evaluation of the Neutron Background in the PandaX-II Experiment
Authors:
Qiuhong Wang,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Lisheng Geng,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Peng Ji,
Xiangdong Ji,
Yonglin Ju,
Yihui Lai,
Kun Liang
, et al. (38 additional authors not shown)
Abstract:
In dark matter direct detection experiments, neutron is a serious source of background, which can mimic the dark matter-nucleus scattering signals. In this paper, we present an improved evaluation of the neutron background in the PandaX-II dark matter experiment by a novel approach. Instead of fully relying on the Monte Carlo simulation, the overall neutron background is determined from the neutro…
▽ More
In dark matter direct detection experiments, neutron is a serious source of background, which can mimic the dark matter-nucleus scattering signals. In this paper, we present an improved evaluation of the neutron background in the PandaX-II dark matter experiment by a novel approach. Instead of fully relying on the Monte Carlo simulation, the overall neutron background is determined from the neutron-induced high energy signals in the data. In addition, the probability of producing a dark-matter-like background per neutron is evaluated with a complete Monte Carlo generator, where the correlated emission of neutron(s) and $γ$(s) in the ($α$, n) reactions and spontaneous fissions is taken into consideration. With this method, the neutron backgrounds in the Run 9 (26-ton-day) and Run 10 (28-ton-day) data sets of PandaX-II are estimated to be 0.66$\pm$0.24 and 0.47$\pm$0.25 events, respectively.
△ Less
Submitted 24 July, 2019; v1 submitted 1 July, 2019;
originally announced July 2019.
-
Searching for Neutrino-less Double Beta Decay of $^{136}$Xe with PandaX-II Liquid Xenon Detector
Authors:
Kaixiang Ni,
Yihui Lai,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Lisheng Geng,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Peng Ji,
Xiangdong Ji,
Yonglin Ju,
Kun Liang
, et al. (38 additional authors not shown)
Abstract:
We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg…
▽ More
We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg$\cdot$yr of $^{136}$Xe exposure. At the region around $^{136}$Xe decay Q-value of 2458 keV, the energy resolution of PandaX-II is 4.2%. We find no evidence of NLDBD in PandaX-II and establish a lower limit for decay half-life of 2.4 $ \times 10^{23} $ yr at the 90% confidence level, which corresponds to an effective Majorana neutrino mass $m_{ββ} < (1.3 - 3.5)$ eV. This is the first NLDBD result reported from a dual-phase xenon experiment.
△ Less
Submitted 27 June, 2019;
originally announced June 2019.
-
First Measurement of the Total Neutron Cross Section on Argon Between 100 and 800 MeV
Authors:
B. Bhandari,
J. Bian,
K. Bilton,
C. Callahan,
J. Chaves,
H. Chen,
D. Cline,
R. L. Cooper,
D. Danielson,
J. Danielson,
N. Dokania,
S. Elliott,
S. Fernandes,
S. Gardiner,
G. Garvey,
V. Gehman,
F. Giuliani,
S. Glavin,
M. Gold,
C. Grant,
E. Guardincerri,
T. Haines,
A. Higuera,
J. Y. Ji,
R. Kadel
, et al. (51 additional authors not shown)
Abstract:
We report the first measurement of the neutron cross section on argon in the energy range of 100-800 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. The total cross section is measured from the attenuation coefficient of the neutron flux as it traverses the liquid argon volume. A set of 2,631 candidate interactions is divided…
▽ More
We report the first measurement of the neutron cross section on argon in the energy range of 100-800 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. The total cross section is measured from the attenuation coefficient of the neutron flux as it traverses the liquid argon volume. A set of 2,631 candidate interactions is divided in bins of the neutron kinetic energy calculated from time-of-flight measurements. These interactions are reconstructed with custom-made algorithms specifically designed for the data in a time projection chamber the size of the Mini-CAPTAIN detector. The energy averaged cross section is $0.91 \pm{} 0.10~\mathrm{(stat.)} \pm{} 0.09~\mathrm{(sys.)}~\mathrm{barns}$. A comparison of the measured cross section is made to the GEANT4 and FLUKA event generator packages.
△ Less
Submitted 26 June, 2019; v1 submitted 12 March, 2019;
originally announced March 2019.
-
Topological background discrimination in the PandaX-III neutrinoless double beta decay experiment
Authors:
J Galan,
X Chen,
H Du,
C Fu,
K Giboni,
F Giuliani,
K Han,
B Jiang,
X Ji,
H Lin,
Y Lin,
J Liu,
K Ni,
X Ren,
S Wang,
S Wu,
C Xie,
Y Yang,
D Zhang,
T Zhang,
L Zhao,
S Aune,
Y Bedfer,
E Berthoumieux,
D Calvet
, et al. (42 additional authors not shown)
Abstract:
The PandaX-III experiment plans to search for neutrinoless double beta decay (0$νββ$) of $^{136}$Xe in the China JinPing underground Laboratory (CJPL). The experiment will use a high pressure gaseous Time Projection Chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to the software side of the experiment. As software tool we use REST, a f…
▽ More
The PandaX-III experiment plans to search for neutrinoless double beta decay (0$νββ$) of $^{136}$Xe in the China JinPing underground Laboratory (CJPL). The experiment will use a high pressure gaseous Time Projection Chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to the software side of the experiment. As software tool we use REST, a framework developed for the reconstruction and simulation of TPC-based detector systems. We study the potential for background reduction by introducing appropiate parameters based on the properties of 0$νββ$ events. We exploit for the first time not only the energy density of the electron track-ends, but also the electron scattering angles produced by an electron near the end of its trajectory. To implement this, we have added new algorithms for detector signal and track processing inside REST. Their assessment shows that background can be reduced by about 7 orders of magnitude while keeping 0$νββ$ efficiency above 20% for the PandaX-III baseline readout scheme, a 2-dimensional 3mm-pitch stripped readout. More generally, we use the potential of REST to handle 2D/3D data to assess the impact on signal-to-background significance at different detector granularities, and to validate the PandaX-III baseline choice. Finally, we demonstrate the potential to discriminate surface background events generated at the readout plane in the absence of $t_o$, by making use of event parameters related with the diffusion of electrons.
△ Less
Submitted 22 July, 2019; v1 submitted 10 March, 2019;
originally announced March 2019.
-
Dark matter direct search sensitivity of the PandaX-4T experiment
Authors:
Hongguang Zhang,
Abdusalam Abdukerim,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Binbin Dong,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Xuyuan Guo,
Zhifan Guo,
Ke Han,
Changda He,
Shengming He,
Di Huang,
Xingtao Huang,
Zhou Huang,
Peng Ji,
Xiangdong Ji,
Yonglin Ju,
Shaoli Li,
Yao Li,
Heng Lin
, et al. (35 additional authors not shown)
Abstract:
The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulation study of the expected background in this experiment. In a 2.8-ton fiducial mass and the signal region between 1 to 10 keV electron equivalent energy, the total electron recoil background is found to be 4.9x10^{-5} /(…
▽ More
The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulation study of the expected background in this experiment. In a 2.8-ton fiducial mass and the signal region between 1 to 10 keV electron equivalent energy, the total electron recoil background is found to be 4.9x10^{-5} /(kg day keV). The nuclear recoil background in the same region is 2.8x10^{-7}/(kg day keV). With an exposure of 5.6 ton-years, the sensitivity of PandaX-4T could reach a minimum spin-independent dark matter-nucleon cross section of 6x10^{-48} cm^{2} at a dark matter mass of 40 GeV/c^{2}.
△ Less
Submitted 7 June, 2018; v1 submitted 6 June, 2018;
originally announced June 2018.
-
A novel TOF-PET MRI detector for diagnosis and follow up of the prostate cancer
Authors:
F. Garibaldi,
S. Beging,
R. Canese,
G. Carpinelli,
N. Clinthorne,
S. Colilli,
L. Cosentino P. Finocchiaro,
F. Giuliani,
M. Gricia,
M. Lucentini,
S. Majewski,
E. Monno,
P. Musico,
F. Santavenere,
J. Tödter,
H. Wegener,
K. Ziemons
Abstract:
Prostate cancer is the most common disease in men and the second leading cause of death from cancer. Generic large imaging instruments used in cancer diagnosis have sensitivity, spatial resolution, and contrast inadequate for the task of imaging details of a small organ such as the prostate. In addition, multimodality imaging can play a significant role merging anatomical and functional details co…
▽ More
Prostate cancer is the most common disease in men and the second leading cause of death from cancer. Generic large imaging instruments used in cancer diagnosis have sensitivity, spatial resolution, and contrast inadequate for the task of imaging details of a small organ such as the prostate. In addition, multimodality imaging can play a significant role merging anatomical and functional details coming from simultaneous PET and MRI. Indeed, multi-parametric PET/MRI was demonstrated to improve diagnosis, but it suffers from too many false positives. In order to address the above limits of the current techniques, we have proposed, built and tested, thanks to the TOPEM project funded by Italian National Institute of Nuclear Phisics a prototype of an endorectal PET-TOF/MRI probe. In the applied magnification PET geometry, performance is dominated by a high-resolution detector placed closer to the source. The expected spatial resolution in the selected geometry is about 1.5 mm FWHM and efficiency a factor of 2 with respect to what obtained with the conventional PET scanner. In our experimental studies, we have obtained timing resolution of ~ 320 ps FWHM and at the same time Depth of Interaction (DOI) resolution of under 1 mm. Tests also showed that mutual adverse PET-MR effects are minimal. In addition, the matching endorectal RF coil was designed, built and tested. In the next planned studies, we expect that benefiting from the further progress in scintillator crystal surface treatment, in SiPM technology and associated electronics would allow us to significantly improve TOF resolution
△ Less
Submitted 24 August, 2017;
originally announced August 2017.
-
Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
Authors:
PandaX-II Collaboration,
:,
Xiangyi Cui,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Binbin Dong,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Yikun Gu,
Xuyuan Guo,
Zhifan Guo,
Ke Han,
Changda He,
Di Huang,
Shengming He,
Xingtao Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shaoli Li
, et al. (33 additional authors not shown)
Abstract:
We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events were…
▽ More
We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events were found above the expected background. With a total exposure of 5.4$\times10^4$ kg day, the most stringent upper limit on spin-independent WIMP-nucleon cross section was set for a WIMP with mass larger than 100 GeV/c$^2$, with the lowest exclusion at 8.6$\times10^{-47}$ cm$^2$ at 40 GeV/c$^2$.
△ Less
Submitted 21 September, 2017; v1 submitted 23 August, 2017;
originally announced August 2017.
-
PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure $^{136}$Xe Gas Time Projection Chambers
Authors:
Xun Chen,
Changbo Fu,
Javier Galan,
Karl Giboni,
Franco Giuliani,
Linghui Gu,
Ke Han,
Xiangdong Ji,
Heng Lin,
Jianglai Liu,
Kaixiang Ni,
Hiroki Kusano,
Xiangxiang Ren,
Shaobo Wang,
Yong Yang,
Dan Zhang,
Tao Zhang,
Li Zhao,
Xiangming Sun,
Shouyang Hu,
Siyu Jian,
Xinglong Li,
Xiaomei Li,
Hao Liang,
Huanqiao Zhang
, et al. (45 additional authors not shown)
Abstract:
Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment…
▽ More
Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% $^{136}$Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct tracks of NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure $\sim$5 m of water shielding in all directions. The second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.
△ Less
Submitted 27 October, 2016; v1 submitted 27 October, 2016;
originally announced October 2016.
-
Dark Matter Results from First 98.7-day Data of PandaX-II Experiment
Authors:
PandaX-II Collaboration,
:,
Andi Tan,
Mengjiao Xiao,
Xiangyi Cui,
Xun Chen,
Yunhua Chen,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Haowei Gong,
Shouyang Hu,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Xiaomei Li,
Xinglong Li,
Hao Liang,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Wolfgang Lorenzon
, et al. (29 additional authors not shown)
Abstract:
We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit…
▽ More
We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit to the spin-independent interaction between the ordinary and WIMP dark matter is set for a range of dark matter mass between 3.5 and 1000 GeV/c$^2$. The best upper limit on the scattering cross section is found $2.5\times 10^{-46}$ cm$^2$ for the WIMP mass 40 GeV/c$^2$ at 90% confidence level.
△ Less
Submitted 22 August, 2016; v1 submitted 25 July, 2016;
originally announced July 2016.
-
Dark Matter Search Results from the Commissioning Run of PandaX-II
Authors:
PandaX Collaboration,
Andi Tan,
Xiang Xiao,
Xiangyi Cui,
Xun Chen,
Yunhua Chen,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Haowei Gong,
Shouyang Hu,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Xiaomei Li,
Xinglong Li,
Hao Liang,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Wolfgang Lorenzon,
Yugang Ma
, et al. (29 additional authors not shown)
Abstract:
We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independ…
▽ More
We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independent elastic WIMP-nucleon cross section with a lowest excluded cross section of 2.97$\times$10$^{-45}$~cm$^2$ at a WIMP mass of 44.7~GeV/c$^2$.
△ Less
Submitted 5 June, 2016; v1 submitted 21 February, 2016;
originally announced February 2016.
-
JUNO Conceptual Design Report
Authors:
T. Adam,
F. An,
G. An,
Q. An,
N. Anfimov,
V. Antonelli,
G. Baccolo,
M. Baldoncini,
E. Baussan,
M. Bellato,
L. Bezrukov,
D. Bick,
S. Blyth,
S. Boarin,
A. Brigatti,
T. Brugière,
R. Brugnera,
M. Buizza Avanzini,
J. Busto,
A. Cabrera,
H. Cai,
X. Cai,
A. Cammi,
D. Cao,
G. Cao
, et al. (372 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the dete…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4$σ$, and determine neutrino oscillation parameters $\sin^2θ_{12}$, $Δm^2_{21}$, and $|Δm^2_{ee}|$ to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. $\sim$17,000 508-mm diameter PMTs with high quantum efficiency provide $\sim$75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.
△ Less
Submitted 28 September, 2015; v1 submitted 28 August, 2015;
originally announced August 2015.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Authors:
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
K. Boudjemline,
M. G. Boulay B. Cai T. Caldwell,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Contreras,
K. Dering,
F. Duncan,
R. Ford,
R. Gagnon F. Giuliani,
M. Gold V. V. Golovko,
P. Gorel,
K. Graham,
D. R. Grant,
R. Hakobyan,
A. L. Hallin,
P. Harvey,
C. Hearns,
C. J. Jillings,
M. Kuźniak,
I. Lawson,
O. Li
, et al. (27 additional authors not shown)
Abstract:
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.…
▽ More
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.
△ Less
Submitted 23 April, 2014; v1 submitted 5 November, 2012;
originally announced November 2012.
-
Heavy Superheated Droplet Detectors as a Probe of Spin-independent WIMP Dark Matter Existence
Authors:
F. Giuliani,
T. Morlat,
T. A. Girard
Abstract:
At present, application of Superheated Droplet Detectors (SDDs) in WIMP dark matter searches has been limited to the spin-dependent sector, owing to the general use of fluorinated refrigerants which have high spin sensitivity. Given their recent demonstration of a significant constraint capability with relatively small exposures and the relative economy of the technique, we consider the potentia…
▽ More
At present, application of Superheated Droplet Detectors (SDDs) in WIMP dark matter searches has been limited to the spin-dependent sector, owing to the general use of fluorinated refrigerants which have high spin sensitivity. Given their recent demonstration of a significant constraint capability with relatively small exposures and the relative economy of the technique, we consider the potential impact of heavy versions of such devices on the spin-independent sector. Limits obtainable from a $\mathrm{CF_{3}I}$-loaded SDD are estimated on the basis of the radiopurity levels and backgrounds already achieved by the SIMPLE and PICASSO experiments. With 34 kgd exposure, equivalent to the current CDMS, such a device may already probe to below 10$^{-6}$ pb in the spin-independent cross section.
△ Less
Submitted 22 February, 2007; v1 submitted 18 November, 2005;
originally announced November 2005.