Triplet Lifetime in Gaseous Argon
Authors:
Michael Akashi-Ronquest,
Amanda Bacon,
Christopher Benson,
Kolahal Bhattacharya,
Thomas Caldwell,
Joseph A. Formaggio,
Dan Gastler,
Brianna Grado-White,
Jeff Griego,
Michael Gold,
Andrew Hime,
Christopher M. Jackson,
Stephen Jaditz,
Chris Kachulis,
Edward Kearns,
Joshua R. Klein,
Antonio Ledesma,
Steve Linden,
Frank Lopez,
Sean MacMullin,
Andrew Mastbaum,
Jocelyn Monroe,
James Nikkel,
John Oertel,
Gabriel D. Orebi Gann
, et al. (5 additional authors not shown)
Abstract:
MiniCLEAN is a single-phase liquid argon dark matter experiment. During the initial cooling phase, impurities within the cold gas ($<$140 K) were monitored by measuring the scintillation light triplet lifetime, and ultimately a triplet lifetime of 3.480 $\pm$ 0.001 (stat.) $\pm$ 0.064 (sys.) $μ$s was obtained, indicating ultra-pure argon. This is the longest argon triplet time constant ever report…
▽ More
MiniCLEAN is a single-phase liquid argon dark matter experiment. During the initial cooling phase, impurities within the cold gas ($<$140 K) were monitored by measuring the scintillation light triplet lifetime, and ultimately a triplet lifetime of 3.480 $\pm$ 0.001 (stat.) $\pm$ 0.064 (sys.) $μ$s was obtained, indicating ultra-pure argon. This is the longest argon triplet time constant ever reported. The effect of quenching of separate components of the scintillation light is also investigated.
△ Less
Submitted 29 August, 2019; v1 submitted 15 March, 2019;
originally announced March 2019.
-
The search for neutron-antineutron oscillations at the Sudbury Neutrino Observatory
Authors:
SNO Collaboration,
B. Aharmim,
S. N. Ahmed,
A. E. Anthony,
N. Barros,
E. W. Beier,
A. Bellerive,
B. Beltran,
M. Bergevin,
S. D. Biller,
K. Boudjemline,
M. G. Boulay,
B. Cai,
Y. D. Chan,
D. Chauhan,
M. Chen,
B. T. Cleveland,
G. A. Cox,
X. Dai,
H. Deng,
J. A. Detwiler,
P. J. Doe,
G. Doucas,
P. -L. Drouin,
F. A. Duncan
, et al. (100 additional authors not shown)
Abstract:
Tests on $B-L$ symmetry breaking models are important probes to search for new physics. One proposed model with $Δ(B-L)=2$ involves the oscillations of a neutron to an antineutron. In this paper a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search was concentrated in oscillations occurring within t…
▽ More
Tests on $B-L$ symmetry breaking models are important probes to search for new physics. One proposed model with $Δ(B-L)=2$ involves the oscillations of a neutron to an antineutron. In this paper a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search was concentrated in oscillations occurring within the deuteron, and 23 events are observed against a background expectation of 30.5 events. These translate to a lower limit on the nuclear lifetime of $1.48\times 10^{31}$ years at 90% confidence level (CL) when no restriction is placed on the signal likelihood space (unbounded). Alternatively, a lower limit on the nuclear lifetime was found to be $1.18\times 10^{31}$ years at 90% CL when the signal was forced into a positive likelihood space (bounded). Values for the free oscillation time derived from various models are also provided in this article. This is the first search for neutron-antineutron oscillation with the deuteron as a target.
△ Less
Submitted 1 May, 2017;
originally announced May 2017.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
A New Method for Measuring Coherent Elastic Neutrino Nucleus Scattering at an Off-Axis High-Energy Neutrino Beam Target
Authors:
S. J. Brice,
R. L. Cooper,
F. DeJongh,
A. Empl,
L. M. Garrison,
A. Hime,
E. Hungerford,
T. Kobilarcik,
B. Loer,
C. Mariani,
M. Mocko,
G. Muhrer,
R. Pattie,
Z. Pavlovic,
E. Ramberg,
K. Scholberg,
R. Tayloe,
R. T. Thornton,
J. Yoo,
A. Young
Abstract:
We present a new experimental method for measuring the process of Coherent Elastic Neutrino Nucleus Scattering (CENNS). This method uses a detector situated transverse to a high energy neutrino beam production target. This detector would be sensitive to the low energy neutrinos arising from pion decays-at-rest in the target. We discuss the physics motivation for making this measurement and outline…
▽ More
We present a new experimental method for measuring the process of Coherent Elastic Neutrino Nucleus Scattering (CENNS). This method uses a detector situated transverse to a high energy neutrino beam production target. This detector would be sensitive to the low energy neutrinos arising from pion decays-at-rest in the target. We discuss the physics motivation for making this measurement and outline the predicted backgrounds and sensitivities using this approach. We report a measurement of neutron backgrounds as found in an off-axis surface location of the Fermilab Booster Neutrino Beam (BNB) target. The results indicate that the Fermilab BNB target is a favorable location for a CENNS experiment.
△ Less
Submitted 22 November, 2013;
originally announced November 2013.
-
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Authors:
P. Cushman,
C. Galbiati,
D. N. McKinsey,
H. Robertson,
T. M. P. Tait,
D. Bauer,
A. Borgland,
B. Cabrera,
F. Calaprice,
J. Cooley,
T. Empl,
R. Essig,
E. Figueroa-Feliciano,
R. Gaitskell,
S. Golwala,
J. Hall,
R. Hill,
A. Hime,
E. Hoppe,
L. Hsu,
E. Hungerford,
R. Jacobsen,
M. Kelsey,
R. F. Lang,
W. H. Lippincott
, et al. (24 additional authors not shown)
Abstract:
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter spa…
▽ More
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter space by examining a spectrum of WIMP models, (c) establish a community consensus on the type of experimental program required to explore that parameter space, and (d) identify the common infrastructure required to practically meet those goals.
△ Less
Submitted 3 November, 2013; v1 submitted 30 October, 2013;
originally announced October 2013.
-
The Majorana experiment: an ultra-low background search for neutrinoless double-beta decay
Authors:
D. G. Phillips II,
E. Aguayo,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
M. Bergevin,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
Y. -D. Chan,
C. D. Christofferson,
J. I. Collar,
D. C. Combs,
R. J. Cooper,
J. A. Detwiler,
P. J. Doe,
Y. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
N. Fields,
P. Finnerty
, et al. (64 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objectiv…
▽ More
The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objective of the Demonstrator is to determine whether a future 1-tonne experiment can achieve a background goal of one count per tonne-year in a narrow region of interest around the 76Ge neutrinoless double-beta decay peak.
△ Less
Submitted 23 November, 2011;
originally announced November 2011.
-
The MiniCLEAN Dark Matter Experiment
Authors:
Andrew Hime
Abstract:
The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with photomultiplier tubes submerged in the cryogen with nearly 4pi coverage of a 500 kg (150 kg) target (fiducial) mass. The high light yield and unique properties of the scintillation time-profile provide effective defense against radioactive background through pulse-shape discrimination and event…
▽ More
The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with photomultiplier tubes submerged in the cryogen with nearly 4pi coverage of a 500 kg (150 kg) target (fiducial) mass. The high light yield and unique properties of the scintillation time-profile provide effective defense against radioactive background through pulse-shape discrimination and event-position reconstruction. The detector is designed also for a liquid-neon target that allows for an independent verification of signal and background and a test of the expected dependence of the WIMP-nucleus interaction rate.
△ Less
Submitted 5 October, 2011;
originally announced October 2011.
-
Fluorescence Efficiency and Visible Re-emission Spectrum of Tetraphenyl Butadiene Films at Extreme Ultraviolet Wavelengths
Authors:
V. M. Gehman,
S. R. Seibert,
K. Rielage,
A. Hime,
Y. Sun,
D. -M. Mei,
J. Maassen,
D. Moore
Abstract:
A large number of current and future experiments in neutrino and dark matter detection use the scintillation light from noble elements as a mechanism for measuring energy deposition. The scintillation light from these elements is produced in the extreme ultraviolet (EUV) range, from 60 - 200 nm. Currently, the most practical technique for observing light at these wavelengths is to surround the sci…
▽ More
A large number of current and future experiments in neutrino and dark matter detection use the scintillation light from noble elements as a mechanism for measuring energy deposition. The scintillation light from these elements is produced in the extreme ultraviolet (EUV) range, from 60 - 200 nm. Currently, the most practical technique for observing light at these wavelengths is to surround the scintillation volume with a thin film of Tetraphenyl Butadiene (TPB) to act as a fluor. The TPB film absorbs EUV photons and reemits visible photons, detectable with a variety of commercial photosensors. Here we present a measurement of the re-emission spectrum of TPB films when illuminated with 128, 160, 175, and 250 nm light. We also measure the fluorescence efficiency as a function of incident wavelength from 120 to 250 nm.
△ Less
Submitted 21 September, 2011; v1 submitted 16 April, 2011;
originally announced April 2011.
-
A Monte Carlo simulation of the Sudbury Neutrino Observatory proportional counters
Authors:
B. Beltran,
H. Bichsel,
B. Cai,
H. Deng,
J. A. Formaggio,
S. Habib,
A. L. Hallin,
A. Hime,
M. Huang,
C. Kraus,
H. R. Leslie,
J. C. Loach,
R. Martin,
S. McGee,
M. L. Miller,
B. Monreal,
J. Monroe,
N. S. Oblath,
S. J. M. Peeters,
A. W. P. Poon,
G. Prior,
K. Rielage,
R. G. H. Robertson,
M. W. E. Smith,
L. C. Stonehill
, et al. (6 additional authors not shown)
Abstract:
The third phase of the Sudbury Neutrino Observatory (SNO) experiment added an array of 3He proportional counters to the detector. The purpose of this Neutral Current Detection (NCD) array was to observe neutrons resulting from neutral-current solar neutrino-deuteron interactions. We have developed a detailed simulation of the current pulses from the NCD array proportional counters, from the primar…
▽ More
The third phase of the Sudbury Neutrino Observatory (SNO) experiment added an array of 3He proportional counters to the detector. The purpose of this Neutral Current Detection (NCD) array was to observe neutrons resulting from neutral-current solar neutrino-deuteron interactions. We have developed a detailed simulation of the current pulses from the NCD array proportional counters, from the primary neutron capture on 3He through the NCD array signal-processing electronics. This NCD array Monte Carlo simulation was used to model the alpha-decay background in SNO's third-phase 8B solar-neutrino measurement.
△ Less
Submitted 13 April, 2011;
originally announced April 2011.
-
Measurement of scintillation efficiency for nuclear recoils in liquid argon
Authors:
D. Gastler,
E. Kearns,
A. Hime,
L. C. Stonehill,
S. Seibert,
J. Klein,
W. H. Lippincott,
D. N. McKinsey,
J. A. Nikkel
Abstract:
The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
△ Less
Submitted 8 May, 2012; v1 submitted 2 April, 2010;
originally announced April 2010.