Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–50 of 60 results for author: Nikkel, J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2402.13256  [pdf, other

    physics.ins-det nucl-ex

    Deep Learning Based Event Reconstruction for Cyclotron Radiation Emission Spectroscopy

    Authors: A. Ashtari Esfahani, S. Böser, N. Buzinsky, M. C. Carmona-Benitez, R. Cervantes, C. Claessens, L. de Viveiros, M. Fertl, J. A. Formaggio, J. K. Gaison, L. Gladstone, M. Grando, M. Guigue, J. Hartse, K. M. Heeger, X. Huyan, A. M. Jones, K. Kazkaz, M. Li, A. Lindman, A. Marsteller, C. Matthé, R. Mohiuddin, B. Monreal, E. C. Morrison , et al. (26 additional authors not shown)

    Abstract: The objective of the Cyclotron Radiation Emission Spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time-frequency plane. Due to the need for excellent instrumental energy resolution in… ▽ More

    Submitted 5 January, 2024; originally announced February 2024.

    Comments: submitted to Machine Learning: Science and Technology

    Journal ref: Machine Learning: Science and Technology, 5 (2024) 025026

  2. arXiv:2401.07462  [pdf, other

    hep-ex physics.ins-det

    Nonproportionality of NaI(Tl) Scintillation Detector for Dark Matter Search Experiments

    Authors: S. M. Lee, G. Adhikari, N. Carlin, J. Y. Cho, J. J. Choi, S. Choi, A. C. Ezeribe, L. E. Fran. a, C. Ha, I. S. Hahn, S. J. Hollick, E. J. Jeon, H. W. Joo, W. G. Kang, M. Kauer, B. H. Kim, H. J. Kim, J. Kim, K. W. Kim, S. H. Kim, S. K. Kim, S. W. Kim, W. K. Kim, Y. D. Kim, Y. H. Kim , et al. (37 additional authors not shown)

    Abstract: We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $γ$ spectroscopy, measures light yields across diverse energy levels from full-energy $γ$ peaks produced by the decays of various isotopes. These $γ$ peaks of interest were produced… ▽ More

    Submitted 10 May, 2024; v1 submitted 14 January, 2024; originally announced January 2024.

    Comments: 12 pages, 7 figures

    Journal ref: Eur. Phys. J. C 84 (2024) 484

  3. arXiv:2311.05010  [pdf, other

    astro-ph.IM physics.ins-det

    Alpha backgrounds in NaI(Tl) crystals of COSINE-100

    Authors: G. Adhikari, N. Carlin, D. F. F. S. Cavalcante, J. Y. Cho, J. J. Choi, S. Choi, A. C. Ezeribe, L. E. Franca, C. Ha, I. S. Hahn, S. J. Hollick, E. J. Jeon, H. W. Joo, W. G. Kang, M. Kauer, B. H. Kim, H. J. Kim, J. Kim, K. W. Kim, S. H. Kim, S. K. Kim, S. W. Kim, W. K. Kim, Y. D. Kim, Y. H. Kim , et al. (38 additional authors not shown)

    Abstract: COSINE-100 is a dark matter direct detection experiment with 106 kg NaI(Tl) as the target material. 210Pb and daughter isotopes are a dominant background in the WIMP region of interest and are detected via beta decay and alpha decay. Analysis of the alpha channel complements the background model as observed in the beta/gamma channel. We present the measurement of the quenching factors and Monte Ca… ▽ More

    Submitted 30 January, 2024; v1 submitted 8 November, 2023; originally announced November 2023.

  4. arXiv:2310.02112  [pdf, other

    physics.ins-det nucl-ex

    Real-time Signal Detection for Cyclotron Radiation Emission Spectroscopy Measurements using Antenna Arrays

    Authors: A. Ashtari Esfahani, S. Böser, N. Buzinsky, M. C. Carmona-Benitez, C. Claessens, L. de Viveiros, M. Fertl, J. A. Formaggio, B. T. Foust, J. K. Gaison, M. Grando, J. Hartse, K. M. Heeger, X. Huyan, A. M. Jones, B. J. P. Jones, K. Kazkaz, B. H. LaRoque, M. Li, A. Lindman, A. Marsteller, C. Matthé, R. Mohiuddin, B. Monreal, B. Mucogllava , et al. (26 additional authors not shown)

    Abstract: Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40~meV, requiring a large supply of tritium atoms store… ▽ More

    Submitted 3 October, 2023; originally announced October 2023.

    Journal ref: JINST 19 (2024) P05073

  5. arXiv:2307.09814  [pdf, other

    hep-ex physics.ins-det

    Search for inelastic WIMP-iodine scattering with COSINE-100

    Authors: G. Adhikari, N. Carlin, J. J. Choi, S. Choi, A. C. Ezeribe, L. E. Franca, C. Ha, I. S. Hahn, S. J. Hollick, E. J. Jeon, J. H. Jo, H. W. Joo, W. G. Kang, M. Kauer, B. H. Kim, H. J. Kim, J. Kim, K. W. Kim, S. H. Kim, S. K. Kim, W. K. Kim, Y. D. Kim, Y. H. Kim, Y. J. Ko, D. H. Lee , et al. (34 additional authors not shown)

    Abstract: We report the results of a search for inelastic scattering of weakly interacting massive particles (WIMPs) off $^{127}$I nuclei using NaI(Tl) crystals with a data exposure of 97.7 kg$\cdot$years from the COSINE-100 experiment. The signature of inelastic WIMP-$^{127}$I scattering is a nuclear recoil accompanied by a 57.6 keV $γ$-ray from the prompt deexcitation, producing a more energetic signal co… ▽ More

    Submitted 30 October, 2023; v1 submitted 19 July, 2023; originally announced July 2023.

    Comments: 8 pages, 5 figures. arXiv admin note: text overlap with arXiv:2104.03537

    Journal ref: Phys. Rev. D 108, 092006 (2023)

  6. arXiv:2304.04674  [pdf, other

    physics.ins-det nucl-ex

    A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

    Authors: CUPID collaboration, K. Alfonso, A. Armatol, C. Augier, F. T. Avignone III, O. Azzolini, M. Balata, A. S. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, V. Berest, M. Beretta, M. Bettelli, M. Biassoni, J. Billard, V. Boldrini, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Campani, C. Capelli , et al. (154 additional authors not shown)

    Abstract: CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of… ▽ More

    Submitted 10 April, 2023; originally announced April 2023.

    Comments: Prepared for submission to JINST; 16 pages, 7 figures, and 1 table

  7. arXiv:2304.04611  [pdf, other

    physics.ins-det nucl-ex

    Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments

    Authors: CUPID, CROSS collaborations, :, K. Alfonso, A. Armatol, C. Augier, F. T. Avignone III, O. Azzolini, M. Balata, I. C. Bandac, A. S. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, V. Berest, M. Beretta, M. Bettelli, M. Biassoni, J. Billard, V. Boldrini, A. Branca, C. Brofferio, C. Bucci , et al. (160 additional authors not shown)

    Abstract: An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied… ▽ More

    Submitted 10 April, 2023; originally announced April 2023.

    Comments: Prepared for submission to JINST; 23 pages, 9 figures, and 4 tables

  8. arXiv:2304.01460  [pdf, other

    hep-ex physics.ins-det

    Search for bosonic super-weakly interacting massive particles at COSINE-100

    Authors: G. Adhikari, N. Carlin, J. J. Choi, S. Choi, A. C. Ezeribe, L. E. Franca, C. Ha, I. S. Hahn, S. J. Hollick, E. J. Jeon, J. H. Jo, H. W. Joo, W. G. Kang, M. Kauer, B. H. Kim, H. J. Kim, J. Kim, K. W. Kim, S. H. Kim, S. K. Kim, W. K. Kim, Y. D. Kim, Y. H. Kim, Y. J. Ko, D. H. Lee , et al. (34 additional authors not shown)

    Abstract: We present results of a search for bosonic super-weakly interacting massive particles (BSW) as keV scale dark matter candidates that is based on an exposure of 97.7 kg$\cdot$year from the COSINE experiment. In this search, we employ, for the first time, Compton-like as well as absorption processes for pseudoscalar and vector BSWs. No evidence for BSWs is found in the mass range from 10… ▽ More

    Submitted 27 August, 2023; v1 submitted 3 April, 2023; originally announced April 2023.

    Journal ref: Phys. Rev. D 108 (2023) L041301

  9. arXiv:2212.08026  [pdf, other

    physics.ins-det hep-ex nucl-ex

    SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

    Authors: A. Ashtari Esfahani, S. Böser, N. Buzinsky, M. C. Carmona-Benitez, C. Claessens, L. de Viveiros, M. Fertl, J. A. Formaggio, L. Gladstone, M. Grando, J. Hartse, K. M. Heeger, X. Huyan, A. M. Jones, K. Kazkaz, M. Li, A. Lindman, C. Matthé, R. Mohiuddin, B. Monreal, R. Mueller, J. A. Nikkel, E. Novitski, N. S. Oblath, J. I. Peña , et al. (20 additional authors not shown)

    Abstract: Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenn… ▽ More

    Submitted 15 December, 2022; originally announced December 2022.

  10. arXiv:2211.09582  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

    Authors: M. Andriamirado, A. B. Balantekin, C. D. Bass, D. E. Bergeron, E. P. Bernard, N. S. Bowden, C. D. Bryan, R. Carr, T. Classen, A. J. Conant, A. Delgado, M. V. Diwan, M. J. Dolinski, A. Erickson, B. T. Foust, J. K. Gaison, A. Galindo-Uribarri, C. E. Gilbert, S. Gokhale, C. Grant, S. Hans, A. B. Hansell, K. M. Heeger, B. Heffron, D. E. Jaffe , et al. (36 additional authors not shown)

    Abstract: This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear se… ▽ More

    Submitted 10 April, 2023; v1 submitted 17 November, 2022; originally announced November 2022.

    Comments: 19 pages, 10 figures

  11. arXiv:2205.04549  [pdf, other

    physics.ins-det nucl-ex

    An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter

    Authors: CUORE Collaboration, D. Q. Adams, C. Alduino, K. Alfonso, F. T. Avignone III, O. Azzolini, G. Bari, F. Bellini, G. Benato, M. Beretta, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Caminata, A. Campani, L. Canonica, X. G. Cao, S. Capelli, C. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali , et al. (96 additional authors not shown)

    Abstract: The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear therm… ▽ More

    Submitted 28 July, 2022; v1 submitted 9 May, 2022; originally announced May 2022.

    Comments: 34 pages, 14 figures, 6 tables

  12. arXiv:2203.07349  [pdf, other

    nucl-ex physics.ins-det

    The Project 8 Neutrino Mass Experiment

    Authors: Project 8 Collaboration, A. Ashtari Esfahani, S. Böser, N. Buzinsky, M. C. Carmona-Benitez, C. Claessens, L. de Viveiros, P. J. Doe, S. Enomoto, M. Fertl, J. A. Formaggio, J. K. Gaison, M. Grando, K. M. Heeger, X. Huyan, A. M. Jones, K. Kazkaz, M. Li, A. Lindman, C. Matthé, R. Mohiuddin, B. Monreal, R. Mueller, J. A. Nikkel, E. Novitski , et al. (23 additional authors not shown)

    Abstract: Measurements of the $β^-$ spectrum of tritium give the most precise direct limits on neutrino mass. Project 8 will investigate neutrino mass using Cyclotron Radiation Emission Spectroscopy (CRES) with an atomic tritium source. CRES is a new experimental technique that has the potential to surmount the systematic and statistical limitations of current-generation direct measurement methods. Atomic t… ▽ More

    Submitted 14 March, 2022; originally announced March 2022.

    Comments: contribution to Snowmass 2021

  13. arXiv:2202.06279  [pdf, other

    physics.ins-det nucl-ex

    Optimization of the first CUPID detector module

    Authors: CUPID collaboration, A. Armatol, C. Augier, F. T. Avignone III, O. Azzolini, M. Balata, K. Ballen, A. S. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, M. Beretta, M. Bettelli, M. Biassoni, J. Billard, V. Boldrini, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, C. Capelli, S. Capelli, L. Cappelli , et al. (153 additional authors not shown)

    Abstract: CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the… ▽ More

    Submitted 13 February, 2022; originally announced February 2022.

    Comments: 10 pages, 5 figures

  14. arXiv:2112.05265  [pdf, other

    physics.ins-det hep-ex

    Viterbi Decoding of CRES Signals in Project 8

    Authors: A. Ashtari Esfahani, Z. Bogorad, S. Böser, N. Buzinsky, C. Claessens, L. de Viveiros, M. Fertl, J. A. Formaggio, L. Gladstone, M. Grando, M. Guigue, J. Hartse, K. M. Heeger, X. Huyan, J. Johnston, A. M. Jones, K. Kazkaz, B. H. LaRoque, M. Li, A. Lindman, C. Matthé, R. Mohiuddin, B. Monreal, J. A. Nikkel, E. Novitski , et al. (23 additional authors not shown)

    Abstract: Cyclotron Radiation Emission Spectroscopy (CRES) is a modern approach for determining charged particle energies via high-precision frequency measurements of the emitted cyclotron radiation. For CRES experiments with gas within the fiducial volume, signal and noise dynamics can be modelled by a hidden Markov model. We introduce a novel application of the Viterbi algorithm in order to derive informa… ▽ More

    Submitted 31 May, 2022; v1 submitted 7 December, 2021; originally announced December 2021.

    Comments: 13 pages, 5 figures

    Journal ref: New J. Phys. 24, 053013 (2022)

  15. arXiv:2108.07883  [pdf, other

    physics.ins-det nucl-ex

    CUORE Opens the Door to Tonne-scale Cryogenics Experiments

    Authors: CUORE Collaboration, D. Q. Adams, C. Alduino, F. Alessandria, K. Alfonso, E. Andreotti, F. T. Avignone III, O. Azzolini, M. Balata, I. Bandac, T. I. Banks, G. Bari, M. Barucci, J. W. Beeman, F. Bellini, G. Benato, M. Beretta, A. Bersani, D. Biare, M. Biassoni, F. Bragazzi, A. Branca, C. Brofferio, A. Bryant, A. Buccheri , et al. (184 additional authors not shown)

    Abstract: The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve… ▽ More

    Submitted 2 December, 2021; v1 submitted 17 August, 2021; originally announced August 2021.

    Comments: 45 pages, 14 figures

    Journal ref: Prog. Part. Nucl. Phys., 122 (2021), Article 103902

  16. arXiv:2107.03934  [pdf, other

    hep-ex nucl-ex physics.ins-det

    PROSPECT-II Physics Opportunities

    Authors: M. Andriamirado, A. B. Balantekin, H. R. Band, C. D. Bass, D. E. Bergeron, N. S. Bowden, C. D. Bryan, R. Carr, T. Classen, A. J. Conant, G. Deichert, A. Delgado, M. V. Diwan, M. J. Dolinski, A. Erickson, B. T. Foust, J. K. Gaison, A. Galindo-Uribari, C. E. Gilbert, C. Grant, S. Hans, A. B. Hansell, K. M. Heeger, B. Heffron, D. E. Jaffe , et al. (37 additional authors not shown)

    Abstract: The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum fr… ▽ More

    Submitted 3 September, 2022; v1 submitted 8 July, 2021; originally announced July 2021.

    Journal ref: J. Phys. G: Nucl. Part. Phys. 49, 070501 (2022)

  17. arXiv:2012.14341  [pdf, other

    physics.data-an hep-ph nucl-ex

    Bayesian Analysis of a Future Beta Decay Experiment's Sensitivity to Neutrino Mass Scale and Ordering

    Authors: A. Ashtari Esfahani, M. Betancourt, Z. Bogorad, S. Böser, N. Buzinsky, R. Cervantes, C. Claessens, L. de Viveiros, M. Fertl, J. A. Formaggio, L. Gladstone, M. Grando, M. Guigue, J. Hartse, K. M. Heeger, X. Huyan, J. Johnston, A. M. Jones, K. Kazkaz, B. H. LaRoque, A. Lindman, R. Mohiuddin, B. Monreal, J. A. Nikkel, E. Novitski , et al. (21 additional authors not shown)

    Abstract: Bayesian modeling techniques enable sensitivity analyses that incorporate detailed expectations regarding future experiments. A model-based approach also allows one to evaluate inferences and predicted outcomes, by calibrating (or measuring) the consequences incurred when certain results are reported. We present procedures for calibrating predictions of an experiment's sensitivity to both continuo… ▽ More

    Submitted 1 June, 2021; v1 submitted 24 December, 2020; originally announced December 2020.

    Comments: 17 pages, 10 figures

    Journal ref: Phys. Rev. C 103, 065501 (2021)

  18. A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility

    Authors: The CUPID Interest Group, A. Armatol, E. Armengaud, W. Armstrong, C. Augier, F. T. Avignone III, O. Azzolini, I. C. Bandac, A. S. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, M. Beretta, L. Bergé, Ch. Bourgeois, M. Biassoni, J. Billard, V. Boldrini, A. Branca, C. Brofferio, C. Bucci, J. M. Calvo-Mozota, J. Camilleri , et al. (156 additional authors not shown)

    Abstract: A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an… ▽ More

    Submitted 27 November, 2020; originally announced November 2020.

    Comments: 19 pages, 7 figures, 1 table

  19. arXiv:2011.13656  [pdf, other

    physics.ins-det nucl-ex

    Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment

    Authors: A. Armatol, E. Armengaud, W. Armstrong, C. Augier, F. T. Avignone III, O. Azzolini, A. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, M. Beretta, L. Bergè, M. Biassoni, J. Billard, V. Boldrini, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, S. Capelli, L. Cappelli, L. Cardani, P. Carniti , et al. (147 additional authors not shown)

    Abstract: The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta… ▽ More

    Submitted 27 November, 2020; originally announced November 2020.

  20. Novel technique for the study of pile-up events in cryogenic bolometers

    Authors: A. Armatol, E. Armengaud, W. Armstrong, C. Augier, F. T. Avignone III, O. Azzolini, A. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, M. Beretta, L. Bergé, M. Biassoni, J. Billard, V. Boldrini, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, S. Capelli, L. Cappelli, L. Cardani, P. Carniti , et al. (144 additional authors not shown)

    Abstract: Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our ap… ▽ More

    Submitted 12 July, 2021; v1 submitted 23 November, 2020; originally announced November 2020.

    Journal ref: Phys. Rev. C 104, 015501 (2021)

  21. arXiv:2011.09295  [pdf, other

    physics.ins-det nucl-ex

    New results from the CUORE experiment

    Authors: A. Giachero, D. Q. Adams, C. Alduino, K. Alfonso, F. T. Avignone III, O. Azzolini, G. Bari, F. Bellini, G. Benato, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Caminata, A. Campani, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali, E. Celi, D. Chiesa , et al. (88 additional authors not shown)

    Abstract: The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion… ▽ More

    Submitted 7 January, 2021; v1 submitted 18 November, 2020; originally announced November 2020.

    Comments: Proceeding of 40th International Conference on High Energy physics (ICHEP2020), July 28 - August 6, 2020, Prague, Czech Republic (virtual meeting). arXiv admin note: text overlap with arXiv:1905.07667

  22. arXiv:2006.02506  [pdf, other

    physics.ins-det hep-ex

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, S. Aviles, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame, J. Bensinger , et al. (365 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent… ▽ More

    Submitted 28 February, 2022; v1 submitted 3 June, 2020; originally announced June 2020.

    Comments: 45 pages (79 inc. tables), 7 figures, 9 tables

    Journal ref: The European Physical Journal C, Volume 80, Article number: 1044 (2020)

  23. arXiv:1910.09124  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The LUX-ZEPLIN (LZ) Experiment

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, J. Barthel, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame , et al. (357 additional authors not shown)

    Abstract: We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n… ▽ More

    Submitted 3 November, 2019; v1 submitted 20 October, 2019; originally announced October 2019.

  24. arXiv:1907.11124  [pdf, ps, other

    physics.comp-ph physics.ins-det

    Locust: C++ software for simulation of RF detection

    Authors: Project 8 Collaboration, A. Ashtari Esfahani, S. Böser, N. Buzinsky, R. Cervantes, C. Claessens, L. de Viveiros, M. Fertl, J. A. Formaggio, L. Gladstone, M. Guigue, K. M. Heeger, J. Johnston, A. M. Jones, K. Kazkaz, B. H. LaRoque, A. Lindman, E. Machado, B. Monreal, E. C. Morrison, J. A. Nikkel, E. Novitski, N. S. Oblath, W. Pettus, R. G. H. Robertson , et al. (14 additional authors not shown)

    Abstract: The Locust simulation package is a new C++ software tool developed to simulate the measurement of time-varying electromagnetic fields using RF detection techniques. Modularity and flexibility allow for arbitrary input signals, while concurrently supporting tight integration with physics-based simulations as input. External signals driven by the Kassiopeia particle tracking package are discussed, d… ▽ More

    Submitted 19 December, 2019; v1 submitted 25 July, 2019; originally announced July 2019.

    Comments: 18 pages, 7 figures

    Journal ref: New J. Phys. 21, 113051 (2019)

  25. The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector

    Authors: PROSPECT Collaboration, J. Ashenfelter, A. B. Balantekin, H. R. Band, C. D. Bass, D. E. Bergeron, D. Berish, N. S. Bowden, J. P. Brodsky, C. D. Bryan, J. J. Cherwinka, T. Classen, A. J. Conant, D. Dean, G. Deichert, M. V. Diwan, M. J. Dolinski, A. Erickson, B. T. Foust, M. Febbraro, J. K. Gaison, A. Galindo-Uribarri, C. E. Gilbert, B. T. Hackett, S. Hans , et al. (40 additional authors not shown)

    Abstract: The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at… ▽ More

    Submitted 16 August, 2019; v1 submitted 17 June, 2019; originally announced June 2019.

    Journal ref: Nucl. Instrum. Methods A, Vol. 944, 2019

  26. Triplet Lifetime in Gaseous Argon

    Authors: Michael Akashi-Ronquest, Amanda Bacon, Christopher Benson, Kolahal Bhattacharya, Thomas Caldwell, Joseph A. Formaggio, Dan Gastler, Brianna Grado-White, Jeff Griego, Michael Gold, Andrew Hime, Christopher M. Jackson, Stephen Jaditz, Chris Kachulis, Edward Kearns, Joshua R. Klein, Antonio Ledesma, Steve Linden, Frank Lopez, Sean MacMullin, Andrew Mastbaum, Jocelyn Monroe, James Nikkel, John Oertel, Gabriel D. Orebi Gann , et al. (5 additional authors not shown)

    Abstract: MiniCLEAN is a single-phase liquid argon dark matter experiment. During the initial cooling phase, impurities within the cold gas ($<$140 K) were monitored by measuring the scintillation light triplet lifetime, and ultimately a triplet lifetime of 3.480 $\pm$ 0.001 (stat.) $\pm$ 0.064 (sys.) $μ$s was obtained, indicating ultra-pure argon. This is the longest argon triplet time constant ever report… ▽ More

    Submitted 29 August, 2019; v1 submitted 15 March, 2019; originally announced March 2019.

  27. A Low Mass Optical Grid for the PROSPECT Reactor Antineutrino Detector

    Authors: PROSPECT Collaboration, J. Ashenfelter, A. B. Balantekin, H. R. Band, C. D. Bass, D. E. Bergeron, D. Berish, N. S. Bowden, J. P. Brodsky, C. D. Bryan, J. J. Cherwinka, T. Classen, A. J. Conant, D. Davee, D. Dean, G. Deichert, A. E. Detweiler M. V. Diwan, M. J. Dolinski, A. Erickson, M. Febbraro, B. T. Foust, J. K. Gaison, A. Galindo-Uribarri, Y. Gebre, C. E. Gilbert , et al. (45 additional authors not shown)

    Abstract: PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of… ▽ More

    Submitted 9 April, 2019; v1 submitted 18 February, 2019; originally announced February 2019.

    Comments: 31 pages, 28 figures

  28. Lithium-loaded Liquid Scintillator Production for the PROSPECT experiment

    Authors: PROSPECT Collaboration, J. Ashenfelter, A. B. Balantekin, H. R. Band, C. D. Bass, D. E. Bergeron, D. Berish, L. J. Bignell, N. S. Bowden, J. P. Brodsky, C. D. Bryan, C. Camilo Reyes, S. Campos, J. J. Cherwinka, T. Classen, A. J. Conant, D. Davee, D. Dean, G. Deichert, R. Diaz Perez, M. V. Diwan, M. J. Dolinski, A. Erickson, M. Febbraro, B. T. Foust , et al. (45 additional authors not shown)

    Abstract: This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a… ▽ More

    Submitted 27 March, 2019; v1 submitted 16 January, 2019; originally announced January 2019.

    Comments: 16 pages, 15 figures

    Journal ref: J. Ashenfelter et al 2019 JINST 14 P03026

  29. arXiv:1901.02844  [pdf, other

    physics.ins-det nucl-ex

    Electron Radiated Power in Cyclotron Radiation Emission Spectroscopy Experiments

    Authors: A. Ashtari Esfahani, V. Bansal, S. Boser, N. Buzinsky, R. Cervantes, C. Claessens, L. de Viveiros, P. J. Doe, M. Fertl, J. A. Formaggio, L. Gladstone, M. Guigue, K. M. Heeger, J. Johnston, A. M. Jones, K. Kazkaz, B. H. LaRoque, M. Leber, A. Lindman, E. Machado, B. Monreal, E. C. Morrison, J. A. Nikkel, E. Novitski, N. S. Oblath , et al. (16 additional authors not shown)

    Abstract: The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about… ▽ More

    Submitted 9 January, 2019; originally announced January 2019.

    Comments: 15 pages, 10 figures

    Journal ref: Phys. Rev. C 99, 055501 (2019)

  30. arXiv:1812.10877  [pdf, other

    nucl-ex hep-ex physics.ins-det

    Measurement of the Antineutrino Spectrum from $^{235}$U Fission at HFIR with PROSPECT

    Authors: PROSPECT Collaboration, J. Ashenfelter, A. B. Balantekin, H. R. Band, C. D. Bass, D. E. Bergeron, D. Berish, N. S. Bowden, J. P. Brodsky, C. D. Bryan, J. J. Cherwinka, T. Classen, A. J. Conant, A. A. Cox, D. Davee, D. Dean, G. Deichert, M. V. Diwan, M. J. Dolinski, A. Erickson, M. Febbraro, B. T. Foust, J. K. Gaison, A. Galindo-Uribarri, C. E. Gilbert , et al. (45 additional authors not shown)

    Abstract: This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays… ▽ More

    Submitted 28 June, 2019; v1 submitted 27 December, 2018; originally announced December 2018.

    Journal ref: Phys. Rev. Lett. 122, 251801 (2019)

  31. arXiv:1811.04737  [pdf, other

    physics.soc-ph physics.ins-det

    Neutrino-based tools for nuclear verification and diplomacy in North Korea

    Authors: Rachel Carr, Jonathon Coleman, Mikhail Danilov, Giorgio Gratta, Karsten Heeger, Patrick Huber, YuenKeung Hor, Takeo Kawasaki, Soo-Bong Kim, Yeongduk Kim, John Learned, Manfred Lindner, Kyohei Nakajima, James Nikkel, Seon-Hee Seo, Fumihiko Suekane, Antonin Vacheret, Wei Wang, James Wilhelmi, Liang Zhan

    Abstract: We present neutrino-based options for verifying that the nuclear reactors at North Korea's Yongbyon Nuclear Research Center are no longer operating or that they are operating in an agreed manner, precluding weapons production. Neutrino detectors may be a mutually agreeable complement to traditional verification protocols because they do not require access inside reactor buildings, could be install… ▽ More

    Submitted 25 July, 2019; v1 submitted 8 November, 2018; originally announced November 2018.

    Journal ref: Science & Global Security, 27:1, 15-28 (2019)

  32. The PROSPECT Reactor Antineutrino Experiment

    Authors: PROSPECT Collaboration, J. Ashenfelter, A. B. Balantekin, C. Baldenegro, H. R. Band, C. D. Bass, D. E. Bergeron, D. Berish, L. J. Bignell, N. S. Bowden, J. Boyle, J. Bricco, J. P. Brodsky, C. D. Bryan, A. Bykadorova Telles, J. J. Cherwinka, T. Classen, K. Commeford, A. Conant, A. A. Cox, D. Davee, D. Dean, G. Deichert, M. V. Diwan, M. J. Dolinski , et al. (64 additional authors not shown)

    Abstract: The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reacto… ▽ More

    Submitted 21 August, 2019; v1 submitted 31 July, 2018; originally announced August 2018.

    Comments: 30 pages, 33 figures; updated with journal revision and reference

    Journal ref: Nucl.Instrum.Meth. A922 (2019) 287-309

  33. arXiv:1805.09245  [pdf, other

    physics.ins-det hep-ex

    Performance of a segmented $^{6}$Li-loaded liquid scintillator detector for the PROSPECT experiment

    Authors: J. Ashenfelter, A. B. Balantekin, H. R. Band, C. D. Bass, D. E. Bergeron, D. Berish, N. S. Bowden, J. P. Brodsky, C. D. Bryan, A. Bykadorova Telles, J. J. Cherwinka, T. Classen, K. Commeford, A. Conant, D. Davee, G. Deichert, M. V. Diwan, M. J. Dolinski, A. Erickson, B. T. Foust, J. K. Gaison, A. Galindo-Uribarri, K. Gilje, B. Hackett, K. Han , et al. (41 additional authors not shown)

    Abstract: This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source a… ▽ More

    Submitted 29 June, 2018; v1 submitted 23 May, 2018; originally announced May 2018.

    Comments: 16 pages, 13 figures; minor edits to design detail and references

    Journal ref: J. Ashenfelter et al 2018 JINST 13 P06023

  34. arXiv:1703.09144  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Technical Design Report

    Authors: B. J. Mount, S. Hans, R. Rosero, M. Yeh, C. Chan, R. J. Gaitskell, D. Q. Huang, J. Makkinje, D. C. Malling, M. Pangilinan, C. A. Rhyne, W. C. Taylor, J. R. Verbus, Y. D. Kim, H. S. Lee, J. Lee, D. S. Leonard, J. Li, J. Belle, A. Cottle, W. H. Lippincott, D. J. Markley, T. J. Martin, M. Sarychev, T. E. Tope , et al. (237 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.

    Submitted 27 March, 2017; originally announced March 2017.

    Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>

    Report number: LBNL-1007256

  35. arXiv:1703.05761  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Project 8 detector upgrades for a tritium beta decay spectrum using cyclotron radiation

    Authors: A Ashtari Esfahani, S Böser, C Claessens, L de Viveiros, P J Doe, S Doeleman, M Fertl, E C Finn, J A Formaggio, M Guigue, K M Heeger, A M Jones, K Kazkaz, B H LaRoque, E Machado, B Monreal, J A Nikkel, N S Oblath, R G H Robertson, L J Rosenberg, G Rybka, L Saldaña, P L Slocum, J R Tedeschi, T Thümmler , et al. (5 additional authors not shown)

    Abstract: Following the successful observation of single conversion electrons from $^{83m}$Kr using Cyclotron Radiation Emission Spectroscopy (CRES), Project 8 is now advancing its focus toward a tritium beta decay spectrum. A tritium spectrum will be an important next step toward a direct measurement of the neutrino mass for Project 8. Here we discuss recent progress on the development and commissioning of… ▽ More

    Submitted 15 March, 2017; originally announced March 2017.

    Comments: 3 pages, 2 figures, Proceedings of Neutrino 2016, XXVII International Conference on Neutrino Physics and Astrophysics, 4-9 July 2016, London, UK

  36. arXiv:1703.05760  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Results from the Project 8 phase-1 cyclotron radiation emission spectroscopy detector

    Authors: A Ashtari Esfahani, S Böser, C Claessens, L de Viveiros, P J Doe, S Doeleman, M Fertl, E C Finn, J A Formaggio, M Guigue, K M Heeger, A M Jones, K Kazkaz, B H LaRoque, E Machado, B Monreal, J A Nikkel, N S Oblath, R G H Robertson, L J Rosenberg, G Rybka, L Saldaña, P L Slocum, J R Tedeschi, T Thümmler , et al. (5 additional authors not shown)

    Abstract: The Project 8 collaboration seeks to measure the absolute neutrino mass scale by means of precision spectroscopy of the beta decay of tritium. Our technique, cyclotron radiation emission spectroscopy, measures the frequency of the radiation emitted by electrons produced by decays in an ambient magnetic field. Because the cyclotron frequency is inversely proportional to the electron's Lorentz facto… ▽ More

    Submitted 15 March, 2017; originally announced March 2017.

    Comments: 3 pages; 2 figures; Proceedings of Neutrino 2016, XXVII International Conference on Neutrino Physics and Astrophysics, 4-9 July 2016, London, UK

  37. arXiv:1703.05759  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Project 8 Phase III Design Concept

    Authors: A Ashtari Esfahani, S Böser, C Claessens, L de Viveiros, P J Doe, S Doeleman, M Fertl, E C Finn, J A Formaggio, M Guigue, K M Heeger, A M Jones, K Kazkaz, B H LaRoque, E Machado, B Monreal, J A Nikkel, N S Oblath, R G H Robertson, L J Rosenberg, G Rybka, L Saldaña, P L Slocum, J R Tedeschi, T Thümmler , et al. (5 additional authors not shown)

    Abstract: We present a working concept for Phase III of the Project 8 experiment, aiming to achieve a neutrino mass sensitivity of $2~\mathrm{eV}$ ($90~\%$ C.L.) using a large volume of molecular tritium and a phased antenna array. The detection system is discussed in detail.

    Submitted 15 March, 2017; originally announced March 2017.

    Comments: 3 pages, 3 figures, Proceedings of Neutrino 2016, XXVII International Conference on Neutrino Physics and Astrophysics, 4-9 July 2016, London, UK

  38. arXiv:1703.02037  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Determining the neutrino mass with Cyclotron Radiation Emission Spectroscopy - Project 8

    Authors: Ali Ashtari Esfahani, David M. Asner, Sebastian Böser, Raphael Cervantes, Christine Claessens, Luiz de Viveiros, Peter J. Doe, Shepard Doeleman, Justin L. Fernandes, Martin Fertl, Erin C. Finn, Joseph A. Formaggio, Daniel Furse, Mathieu Guigue, Karsten M. Heeger, A. Mark Jones, Kareem Kazkaz, Jared A. Kofron, Callum Lamb, Benjamin H. LaRoque, Eric Machado, Elizabeth L. McBride, Michael L. Miller, Benjamin Monreal, Prajwal Mohanmurthy , et al. (19 additional authors not shown)

    Abstract: The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(ν_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observati… ▽ More

    Submitted 6 March, 2017; originally announced March 2017.

    Comments: 19 pages, 8 figures, to be published in Journal of Physics G

    Journal ref: JPhysG 44 (2017) 5

  39. Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, I. J. Arnquist, M. Arthurs, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, J. Belle, P. Beltrame, T. Benson, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. Bolozdynya, B. Boxer, R. Bramante, P. Brás, J. H. Buckley, V. V. Bugaev , et al. (180 additional authors not shown)

    Abstract: The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,… ▽ More

    Submitted 26 September, 2017; v1 submitted 8 February, 2017; originally announced February 2017.

    Comments: 13 pages, 3 figures, accepted for publication in Astroparticle Physics

  40. arXiv:1509.02910  [pdf

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Conceptual Design Report

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, P. Bauer, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. I. Bolozdynya, E. M. Boulton, R. Bramante, J. H. Buckley, V. V. Bugaev, R. Bunker, S. Burdin, J. K. Busenitz , et al. (170 additional authors not shown)

    Abstract: The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp… ▽ More

    Submitted 23 September, 2015; v1 submitted 9 September, 2015; originally announced September 2015.

    Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors

    Report number: LBNL-190005

  41. arXiv:1502.04213  [pdf, other

    physics.ins-det

    Index of refraction, Rayleigh scattering length, and Sellmeier coefficients in solid and liquid argon and xenon

    Authors: Emily Grace, Alistair Butcher, Jocelyn Monroe, James A. Nikkel

    Abstract: Large liquid argon detectors have become widely used in low rate experiments, including dark matter and neutrino research. However, the optical properties of liquid argon are not well understood at the large scales relevant for current and near-future detectors.The index of refraction of liquid argon at the scin- tillation wavelength has not been measured, and current Rayleigh scattering length ca… ▽ More

    Submitted 11 August, 2017; v1 submitted 14 February, 2015; originally announced February 2015.

    Comments: 11 pages, 4 figures

  42. arXiv:1408.1914  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

    Authors: M. Akashi-Ronquest, P. -A. Amaudruz, M. Batygov, B. Beltran, M. Bodmer, M. G. Boulay, B. Broerman, B. Buck, A. Butcher, B. Cai, T. Caldwell, M. Chen, Y. Chen, B. Cleveland, K. Coakley, K. Dering, F. A. Duncan, J. A. Formaggio, R. Gagnon, D. Gastler, F. Giuliani, M. Gold, V. V. Golovko, P. Gorel, K. Graham , et al. (57 additional authors not shown)

    Abstract: Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We… ▽ More

    Submitted 12 December, 2014; v1 submitted 8 August, 2014; originally announced August 2014.

    Comments: 16 pages, 16 figures

  43. arXiv:1403.4842  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Update on the MiniCLEAN Dark Matter Experiment

    Authors: K. Rielage, M. Akashi-Ronquest, M. Bodmer, R. Bourque, B. Buck, A. Butcher, T. Caldwell, Y. Chen, K. Coakley, E. Flores, J. A. Formaggio, D. Gastler, F. Giuliani, M. Gold, E. Grace, J. Griego, N. Guerrero, V. Guiseppe, R. Henning, A. Hime, S. Jaditz, C. Kachulis, E. Kearns, J. Kelsey, J. R. Klein , et al. (21 additional authors not shown)

    Abstract: The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o… ▽ More

    Submitted 19 March, 2014; originally announced March 2014.

    Comments: To appear in the Proceedings of the TAUP 2013 Conference (F. Avignone & W. Haxton, editors, Physics Procedia, Elsevier)

    Report number: LA-UR-14-21626

  44. Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping

    Authors: Christopher G. Wahl, Ethan P. Bernard, W. Hugh Lippincott, James A. Nikkel, Yunchang Shin, Daniel N. McKinsey

    Abstract: Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in light or signal yield, energy resolution, and particle discrimination. In this study, we investigate the detector response for xenon dopant concentrations from… ▽ More

    Submitted 20 April, 2014; v1 submitted 3 March, 2014; originally announced March 2014.

    Journal ref: JINST 9 P06013

  45. arXiv:1310.8214  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    First results from the LUX dark matter experiment at the Sanford Underground Research Facility

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araujo, X. Bai, A. J. Bailey, J. Balajthy, S. Bedikian, E. Bernard, A. Bernstein, A. Bolozdynya, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, K. Clark, T. Coffey, A. Currie, A. Curioni, S. Dazeley, L. de Viveiros, A. Dobi , et al. (78 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li… ▽ More

    Submitted 5 February, 2014; v1 submitted 30 October, 2013; originally announced October 2013.

    Comments: Accepted by Phys. Rev. Lett. Appendix A included as supplementary material with PRL article

    Journal ref: Phys. Rev. Lett. 112, 091303 (2014)

  46. arXiv:1211.3788  [pdf, other

    physics.ins-det hep-ex

    The Large Underground Xenon (LUX) Experiment

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bolozdynya, A. Bradley, D. Byram, S. B. Cahn, C. Camp, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, A. Chiller, C. Chiller, K. Clark, T. Classen, T. Coffey, A. Curioni, E. Dahl, S. Dazeley, L. de Viveiros, A. Dobi, E. Dragowsky, E. Druszkiewicz , et al. (69 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100… ▽ More

    Submitted 21 November, 2012; v1 submitted 15 November, 2012; originally announced November 2012.

    Comments: 50 pages, 16 figures

    Journal ref: Nuclear Inst. and Methods in Physics Research A704 (2013) 111 - 126

  47. arXiv:1211.0909  [pdf, other

    astro-ph.IM nucl-ex physics.ins-det

    Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector

    Authors: P. -A. Amaudruz, M. Batygov, B. Beltran, K. Boudjemline, M. G. Boulay B. Cai T. Caldwell, M. Chen, R. Chouinard, B. T. Cleveland, D. Contreras, K. Dering, F. Duncan, R. Ford, R. Gagnon F. Giuliani, M. Gold V. V. Golovko, P. Gorel, K. Graham, D. R. Grant, R. Hakobyan, A. L. Hallin, P. Harvey, C. Hearns, C. J. Jillings, M. Kuźniak, I. Lawson, O. Li , et al. (27 additional authors not shown)

    Abstract: The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.… ▽ More

    Submitted 23 April, 2014; v1 submitted 5 November, 2012; originally announced November 2012.

    Journal ref: Astroparticle Physics 62, 178-194 (2015)

  48. arXiv:1210.4569  [pdf, other

    astro-ph.IM hep-ex hep-ph physics.ins-det

    Technical Results from the Surface Run of the LUX Dark Matter Experiment

    Authors: LUX Collaboration, D. S. Akerib, X. Bai, E. Bernard, A. Bernstein, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, J. J. Chapman, T. Coffey, A. Dobi, E. Dragowsky, E. Druszkiewicz, B. Edwards, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, M. Gilchriese, C. Hall, M. Hanhardt, M. Ihm, R. G. Jacobsen, L. Kastens , et al. (42 additional authors not shown)

    Abstract: We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed i… ▽ More

    Submitted 22 February, 2013; v1 submitted 16 October, 2012; originally announced October 2012.

  49. arXiv:1207.3665  [pdf, other

    physics.ins-det astro-ph.IM

    The LUX Prototype Detector: Heat Exchanger Development

    Authors: D. S. Akerib, X. Bai, S. Bedikian, A. Bernstein, A. Bolozdynya, A. Bradley, S. Cahn, D. Carr, J. J. Chapman, K. Clark, T. Classen, A. Curioni, C. E. Dahl, S. Dazeley, L. deViveiros, M. Dragowsky, E. Druszkiewicz, S. Fiorucci, R. J. Gaitskell, C. Hall, C. Faham, B. Holbrook, L. Kastens, K. Kazkaz, J. Kwong , et al. (25 additional authors not shown)

    Abstract: The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for ac… ▽ More

    Submitted 20 January, 2013; v1 submitted 16 July, 2012; originally announced July 2012.

    Comments: 12 pages, 9 figures

  50. arXiv:1205.2272  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    An Ultra-Low Background PMT for Liquid Xenon Detectors

    Authors: D. S. Akerib, X. Bai, E. Bernard, A. Bernstein, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, Y-D. Chan, K. Clark, T. Coffey, L. deViveiros, M. Dragowsky, E. Druszkiewicz, B. Edwards, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook, M. Ihm , et al. (42 additional authors not shown)

    Abstract: Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other det… ▽ More

    Submitted 24 June, 2013; v1 submitted 10 May, 2012; originally announced May 2012.

    Comments: v2 updated to include content after reviewer comments (Sep 2012)

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 703, 1 March 2013, Pages 1-6