-
Deep Learning Based Event Reconstruction for Cyclotron Radiation Emission Spectroscopy
Authors:
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
R. Cervantes,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
J. K. Gaison,
L. Gladstone,
M. Grando,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
K. Kazkaz,
M. Li,
A. Lindman,
A. Marsteller,
C. Matthé,
R. Mohiuddin,
B. Monreal,
E. C. Morrison
, et al. (26 additional authors not shown)
Abstract:
The objective of the Cyclotron Radiation Emission Spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time-frequency plane. Due to the need for excellent instrumental energy resolution in…
▽ More
The objective of the Cyclotron Radiation Emission Spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time-frequency plane. Due to the need for excellent instrumental energy resolution in application, highly efficient and accurate track reconstruction methods are desired. Deep learning convolutional neural networks (CNNs) - particularly suited to deal with information-sparse data and which offer precise foreground localization - may be utilized to extract track properties from measured CRES signals (called events) with relative computational ease. In this work, we develop a novel machine learning based model which operates a CNN and a support vector machine in tandem to perform this reconstruction. A primary application of our method is shown on simulated CRES signals which mimic those of the Project 8 experiment - a novel effort to extract the unknown absolute neutrino mass value from a precise measurement of tritium $β^-$-decay energy spectrum. When compared to a point-clustering based technique used as a baseline, we show a relative gain of 24.1% in event reconstruction efficiency and comparable performance in accuracy of track parameter reconstruction.
△ Less
Submitted 5 January, 2024;
originally announced February 2024.
-
Nonproportionality of NaI(Tl) Scintillation Detector for Dark Matter Search Experiments
Authors:
S. M. Lee,
G. Adhikari,
N. Carlin,
J. Y. Cho,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Fran. a,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
S. W. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim
, et al. (37 additional authors not shown)
Abstract:
We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $γ$ spectroscopy, measures light yields across diverse energy levels from full-energy $γ$ peaks produced by the decays of various isotopes. These $γ$ peaks of interest were produced…
▽ More
We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $γ$ spectroscopy, measures light yields across diverse energy levels from full-energy $γ$ peaks produced by the decays of various isotopes. These $γ$ peaks of interest were produced by decays supported by both long and short-lived isotopes. Analyzing peaks from decays supported only by short-lived isotopes presented a unique challenge due to their limited statistics and overlapping energies, which was overcome by long-term data collection and a time-dependent analysis. A key achievement is the direct measurement of the 0.87 keV light yield, resulting from the cascade following electron capture decay of $^{22}$Na from internal contamination. This measurement, previously accessible only indirectly, deepens our understanding of NaI(Tl) scintillator behavior in the region of interest for dark matter searches. This study holds substantial implications for background modeling and the interpretation of dark matter signals in NaI(Tl) experiments.
△ Less
Submitted 10 May, 2024; v1 submitted 14 January, 2024;
originally announced January 2024.
-
Alpha backgrounds in NaI(Tl) crystals of COSINE-100
Authors:
G. Adhikari,
N. Carlin,
D. F. F. S. Cavalcante,
J. Y. Cho,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
S. W. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim
, et al. (38 additional authors not shown)
Abstract:
COSINE-100 is a dark matter direct detection experiment with 106 kg NaI(Tl) as the target material. 210Pb and daughter isotopes are a dominant background in the WIMP region of interest and are detected via beta decay and alpha decay. Analysis of the alpha channel complements the background model as observed in the beta/gamma channel. We present the measurement of the quenching factors and Monte Ca…
▽ More
COSINE-100 is a dark matter direct detection experiment with 106 kg NaI(Tl) as the target material. 210Pb and daughter isotopes are a dominant background in the WIMP region of interest and are detected via beta decay and alpha decay. Analysis of the alpha channel complements the background model as observed in the beta/gamma channel. We present the measurement of the quenching factors and Monte Carlo simulation results and activity quantification of the alpha decay components of the COSINE-100 NaI(Tl) crystals. The data strongly indicate that the alpha decays probabilistically undergo two possible quenching factors but require further investigation. The fitted results are consistent with independent measurements and improve the overall understanding of the COSINE-100 backgrounds. Furthermore, the half-life of 216Po has been measured to be 143.4 +/- 1.2 ms, which is consistent with and more precise than recent measurements.
△ Less
Submitted 30 January, 2024; v1 submitted 8 November, 2023;
originally announced November 2023.
-
Real-time Signal Detection for Cyclotron Radiation Emission Spectroscopy Measurements using Antenna Arrays
Authors:
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
B. T. Foust,
J. K. Gaison,
M. Grando,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
B. J. P. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Li,
A. Lindman,
A. Marsteller,
C. Matthé,
R. Mohiuddin,
B. Monreal,
B. Mucogllava
, et al. (26 additional authors not shown)
Abstract:
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40~meV, requiring a large supply of tritium atoms store…
▽ More
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40~meV, requiring a large supply of tritium atoms stored in a multi-cubic meter detector volume. Antenna arrays are one potential technology compatible with an experiment of this scale, but the capability of an antenna-based CRES experiment to measure the neutrino mass depends on the efficiency of the signal detection algorithms. In this paper, we develop efficiency models for three signal detection algorithms and compare them using simulations from a prototype antenna-based CRES experiment as a case-study. The algorithms include a power threshold, a matched filter template bank, and a neural network based machine learning approach, which are analyzed in terms of their average detection efficiency and relative computational cost. It is found that significant improvements in detection efficiency and, therefore, neutrino mass sensitivity are achievable, with only a moderate increase in computation cost, by utilizing either the matched filter or machine learning approach in place of a power threshold, which is the baseline signal detection algorithm used in previous CRES experiments by Project 8.
△ Less
Submitted 3 October, 2023;
originally announced October 2023.
-
Search for inelastic WIMP-iodine scattering with COSINE-100
Authors:
G. Adhikari,
N. Carlin,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
D. H. Lee
, et al. (34 additional authors not shown)
Abstract:
We report the results of a search for inelastic scattering of weakly interacting massive particles (WIMPs) off $^{127}$I nuclei using NaI(Tl) crystals with a data exposure of 97.7 kg$\cdot$years from the COSINE-100 experiment. The signature of inelastic WIMP-$^{127}$I scattering is a nuclear recoil accompanied by a 57.6 keV $γ$-ray from the prompt deexcitation, producing a more energetic signal co…
▽ More
We report the results of a search for inelastic scattering of weakly interacting massive particles (WIMPs) off $^{127}$I nuclei using NaI(Tl) crystals with a data exposure of 97.7 kg$\cdot$years from the COSINE-100 experiment. The signature of inelastic WIMP-$^{127}$I scattering is a nuclear recoil accompanied by a 57.6 keV $γ$-ray from the prompt deexcitation, producing a more energetic signal compared to the typical WIMP nuclear recoil signal. We found no evidence for this inelastic scattering signature and set a 90 $\%$ confidence level upper limit on the WIMP-proton spin-dependent, inelastic scattering cross section of $1.2 \times 10^{-37} {\rm cm^{2}}$ at the WIMP mass 500 ${\rm GeV/c^{2}}$.
△ Less
Submitted 30 October, 2023; v1 submitted 19 July, 2023;
originally announced July 2023.
-
Search for bosonic super-weakly interacting massive particles at COSINE-100
Authors:
G. Adhikari,
N. Carlin,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
D. H. Lee
, et al. (34 additional authors not shown)
Abstract:
We present results of a search for bosonic super-weakly interacting massive particles (BSW) as keV scale dark matter candidates that is based on an exposure of 97.7 kg$\cdot$year from the COSINE experiment. In this search, we employ, for the first time, Compton-like as well as absorption processes for pseudoscalar and vector BSWs. No evidence for BSWs is found in the mass range from 10…
▽ More
We present results of a search for bosonic super-weakly interacting massive particles (BSW) as keV scale dark matter candidates that is based on an exposure of 97.7 kg$\cdot$year from the COSINE experiment. In this search, we employ, for the first time, Compton-like as well as absorption processes for pseudoscalar and vector BSWs. No evidence for BSWs is found in the mass range from 10 $\mathrm{keV/c}^2$ to 1 $\mathrm{MeV/c}^2$, and we present the exclusion limits on the dimensionless coupling constants to electrons $g_{ae}$ for pseudoscalar and $κ$ for vector BSWs at 90% confidence level. Our results show that these limits are improved by including the Compton-like process in masses of BSW, above $\mathcal{O}(100\,\mathrm{keV/c}^2)$.
△ Less
Submitted 27 August, 2023; v1 submitted 3 April, 2023;
originally announced April 2023.
-
SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration
Authors:
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Grando,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
K. Kazkaz,
M. Li,
A. Lindman,
C. Matthé,
R. Mohiuddin,
B. Monreal,
R. Mueller,
J. A. Nikkel,
E. Novitski,
N. S. Oblath,
J. I. Peña
, et al. (20 additional authors not shown)
Abstract:
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenn…
▽ More
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting $β$-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. We find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.
△ Less
Submitted 15 December, 2022;
originally announced December 2022.
-
Calibration strategy of the PROSPECT-II detector with external and intrinsic sources
Authors:
M. Andriamirado,
A. B. Balantekin,
C. D. Bass,
D. E. Bergeron,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe
, et al. (36 additional authors not shown)
Abstract:
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear se…
▽ More
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.
△ Less
Submitted 10 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
The Project 8 Neutrino Mass Experiment
Authors:
Project 8 Collaboration,
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
P. J. Doe,
S. Enomoto,
M. Fertl,
J. A. Formaggio,
J. K. Gaison,
M. Grando,
K. M. Heeger,
X. Huyan,
A. M. Jones,
K. Kazkaz,
M. Li,
A. Lindman,
C. Matthé,
R. Mohiuddin,
B. Monreal,
R. Mueller,
J. A. Nikkel,
E. Novitski
, et al. (23 additional authors not shown)
Abstract:
Measurements of the $β^-$ spectrum of tritium give the most precise direct limits on neutrino mass. Project 8 will investigate neutrino mass using Cyclotron Radiation Emission Spectroscopy (CRES) with an atomic tritium source. CRES is a new experimental technique that has the potential to surmount the systematic and statistical limitations of current-generation direct measurement methods. Atomic t…
▽ More
Measurements of the $β^-$ spectrum of tritium give the most precise direct limits on neutrino mass. Project 8 will investigate neutrino mass using Cyclotron Radiation Emission Spectroscopy (CRES) with an atomic tritium source. CRES is a new experimental technique that has the potential to surmount the systematic and statistical limitations of current-generation direct measurement methods. Atomic tritium avoids an irreducible systematic uncertainty associated with the final states populated by the decay of molecular tritium. Project 8 will proceed in a phased approach toward a goal of 40 meV/c$^2$ neutrino-mass sensitivity.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Viterbi Decoding of CRES Signals in Project 8
Authors:
A. Ashtari Esfahani,
Z. Bogorad,
S. Böser,
N. Buzinsky,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Grando,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Li,
A. Lindman,
C. Matthé,
R. Mohiuddin,
B. Monreal,
J. A. Nikkel,
E. Novitski
, et al. (23 additional authors not shown)
Abstract:
Cyclotron Radiation Emission Spectroscopy (CRES) is a modern approach for determining charged particle energies via high-precision frequency measurements of the emitted cyclotron radiation. For CRES experiments with gas within the fiducial volume, signal and noise dynamics can be modelled by a hidden Markov model. We introduce a novel application of the Viterbi algorithm in order to derive informa…
▽ More
Cyclotron Radiation Emission Spectroscopy (CRES) is a modern approach for determining charged particle energies via high-precision frequency measurements of the emitted cyclotron radiation. For CRES experiments with gas within the fiducial volume, signal and noise dynamics can be modelled by a hidden Markov model. We introduce a novel application of the Viterbi algorithm in order to derive informational limits on the optimal detection of cyclotron radiation signals in this class of gas-filled CRES experiments, thereby providing concrete limits from which future reconstruction algorithms, as well as detector designs, can be constrained. The validity of the resultant decision rules is confirmed using both Monte Carlo and Project 8 data.
△ Less
Submitted 31 May, 2022; v1 submitted 7 December, 2021;
originally announced December 2021.
-
PROSPECT-II Physics Opportunities
Authors:
M. Andriamirado,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribari,
C. E. Gilbert,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe
, et al. (37 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum fr…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum from $^{235}$U, and demonstrated the observation of reactor antineutrinos in an aboveground detector with good energy resolution and well-controlled backgrounds. The PROSPECT collaboration is now preparing an upgraded detector, PROSPECT-II, to probe yet unexplored parameter space for sterile neutrinos and contribute to a full resolution of the Reactor Antineutrino Anomaly, a longstanding puzzle in neutrino physics. By pressing forward on the world's most precise measurement of the $^{235}$U antineutrino spectrum and measuring the absolute flux of antineutrinos from $^{235}$U, PROSPECT-II will sharpen a tool with potential value for basic neutrino science, nuclear data validation, and nuclear security applications. Following a two-year deployment at HFIR, an additional PROSPECT-II deployment at a low enriched uranium reactor could make complementary measurements of the neutrino yield from other fission isotopes. PROSPECT-II provides a unique opportunity to continue the study of reactor antineutrinos at short baselines, taking advantage of demonstrated elements of the original PROSPECT design and close access to a highly enriched uranium reactor core.
△ Less
Submitted 3 September, 2022; v1 submitted 8 July, 2021;
originally announced July 2021.
-
Bayesian Analysis of a Future Beta Decay Experiment's Sensitivity to Neutrino Mass Scale and Ordering
Authors:
A. Ashtari Esfahani,
M. Betancourt,
Z. Bogorad,
S. Böser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Grando,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
A. Lindman,
R. Mohiuddin,
B. Monreal,
J. A. Nikkel,
E. Novitski
, et al. (21 additional authors not shown)
Abstract:
Bayesian modeling techniques enable sensitivity analyses that incorporate detailed expectations regarding future experiments. A model-based approach also allows one to evaluate inferences and predicted outcomes, by calibrating (or measuring) the consequences incurred when certain results are reported. We present procedures for calibrating predictions of an experiment's sensitivity to both continuo…
▽ More
Bayesian modeling techniques enable sensitivity analyses that incorporate detailed expectations regarding future experiments. A model-based approach also allows one to evaluate inferences and predicted outcomes, by calibrating (or measuring) the consequences incurred when certain results are reported. We present procedures for calibrating predictions of an experiment's sensitivity to both continuous and discrete parameters. Using these procedures and a new Bayesian model of the $β$-decay spectrum, we assess a high-precision $β$-decay experiment's sensitivity to the neutrino mass scale and ordering, for one assumed design scenario. We find that such an experiment could measure the electron-weighted neutrino mass within $\sim40\,$meV after 1 year (90$\%$ credibility). Neutrino masses $>500\,$meV could be measured within $\approx5\,$meV. Using only $β$-decay and external reactor neutrino data, we find that next-generation $β$-decay experiments could potentially constrain the mass ordering using a two-neutrino spectral model analysis. By calibrating mass ordering results, we identify reporting criteria that can be tuned to suppress false ordering claims. In some cases, a two-neutrino analysis can reveal that the mass ordering is inverted, an unobtainable result for the traditional one-neutrino analysis approach.
△ Less
Submitted 1 June, 2021; v1 submitted 24 December, 2020;
originally announced December 2020.
-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Locust: C++ software for simulation of RF detection
Authors:
Project 8 Collaboration,
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Guigue,
K. M. Heeger,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
A. Lindman,
E. Machado,
B. Monreal,
E. C. Morrison,
J. A. Nikkel,
E. Novitski,
N. S. Oblath,
W. Pettus,
R. G. H. Robertson
, et al. (14 additional authors not shown)
Abstract:
The Locust simulation package is a new C++ software tool developed to simulate the measurement of time-varying electromagnetic fields using RF detection techniques. Modularity and flexibility allow for arbitrary input signals, while concurrently supporting tight integration with physics-based simulations as input. External signals driven by the Kassiopeia particle tracking package are discussed, d…
▽ More
The Locust simulation package is a new C++ software tool developed to simulate the measurement of time-varying electromagnetic fields using RF detection techniques. Modularity and flexibility allow for arbitrary input signals, while concurrently supporting tight integration with physics-based simulations as input. External signals driven by the Kassiopeia particle tracking package are discussed, demonstrating conditional feedback between Locust and Kassiopeia during software execution. An application of the simulation to the Project 8 experiment is described. Locust is publicly available at https://github.com/project8/locust_mc.
△ Less
Submitted 19 December, 2019; v1 submitted 25 July, 2019;
originally announced July 2019.
-
The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
M. Febbraro,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert,
B. T. Hackett,
S. Hans
, et al. (40 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at…
▽ More
The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. This paper describes the design, operation, and performance of the PROSPECT source calibration system.
△ Less
Submitted 16 August, 2019; v1 submitted 17 June, 2019;
originally announced June 2019.
-
A Low Mass Optical Grid for the PROSPECT Reactor Antineutrino Detector
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
D. Davee,
D. Dean,
G. Deichert,
A. E. Detweiler M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
Y. Gebre,
C. E. Gilbert
, et al. (45 additional authors not shown)
Abstract:
PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of…
▽ More
PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of $\overlineν_e$ interactions in the detector. This paper is the technical reference for this PROSPECT subsystem, describing its design, fabrication, quality assurance, transportation and assembly in detail. In addition, the dimensional, optical and mechanical characterizations of optical grid components and the assembled PROSPECT target are also presented. The technical information and characterizations detailed here will inform geometry-related inputs for PROSPECT physics analysis, and can guide a variety of future particle detection development efforts, such as those using optically reflecting materials or filament-based 3D printing.
△ Less
Submitted 9 April, 2019; v1 submitted 18 February, 2019;
originally announced February 2019.
-
Lithium-loaded Liquid Scintillator Production for the PROSPECT experiment
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
L. J. Bignell,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
C. Camilo Reyes,
S. Campos,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
D. Davee,
D. Dean,
G. Deichert,
R. Diaz Perez,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro,
B. T. Foust
, et al. (45 additional authors not shown)
Abstract:
This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a…
▽ More
This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a pure liquid scintillator reference, and pulse shape discrimination capability. Fifty-seven batches passed the quality assurance criteria and were used for the PROSPECT experiment.
△ Less
Submitted 27 March, 2019; v1 submitted 16 January, 2019;
originally announced January 2019.
-
Electron Radiated Power in Cyclotron Radiation Emission Spectroscopy Experiments
Authors:
A. Ashtari Esfahani,
V. Bansal,
S. Boser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
P. J. Doe,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Guigue,
K. M. Heeger,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Leber,
A. Lindman,
E. Machado,
B. Monreal,
E. C. Morrison,
J. A. Nikkel,
E. Novitski,
N. S. Oblath
, et al. (16 additional authors not shown)
Abstract:
The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about…
▽ More
The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about the electron's kinematic parameters, and extract a set of measurables that in a suitably designed system are sufficient for disentangling the electron's kinetic energy from the rest of its kinematic features. This lays the groundwork for high-resolution energy measurements in future CRES experiments, such as the Project 8 neutrino mass measurement.
△ Less
Submitted 9 January, 2019;
originally announced January 2019.
-
Measurement of the Antineutrino Spectrum from $^{235}$U Fission at HFIR with PROSPECT
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
A. A. Cox,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert
, et al. (45 additional authors not shown)
Abstract:
This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays…
▽ More
This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to $^{235}$U. Despite broad agreement, comparison of the Huber $^{235}$U model to the measured spectrum produces a $χ^2/ndf = 51.4/31$, driven primarily by deviations in two localized energy regions. The measured $^{235}$U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the $\overline{ν_{e}}$ energy region of 5-7MeV.
△ Less
Submitted 28 June, 2019; v1 submitted 27 December, 2018;
originally announced December 2018.
-
The PROSPECT Reactor Antineutrino Experiment
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
C. Baldenegro,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
L. J. Bignell,
N. S. Bowden,
J. Boyle,
J. Bricco,
J. P. Brodsky,
C. D. Bryan,
A. Bykadorova Telles,
J. J. Cherwinka,
T. Classen,
K. Commeford,
A. Conant,
A. A. Cox,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski
, et al. (64 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reacto…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT is a movable 4-ton antineutrino detector covering distances of 7m to 13m from the High Flux Isotope Reactor core. It will probe the best-fit point of the $\barν_e$ disappearance experiments at 4$σ$ in 1 year and the favored regions of the sterile neutrino parameter space at more than 3$σ$ in 3 years. PROSPECT will test the origin of spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly. This paper describes the design, construction, and commissioning of PROSPECT and reports first data characterizing the performance of the PROSPECT antineutrino detector.
△ Less
Submitted 21 August, 2019; v1 submitted 31 July, 2018;
originally announced August 2018.
-
Performance of a segmented $^{6}$Li-loaded liquid scintillator detector for the PROSPECT experiment
Authors:
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
A. Bykadorova Telles,
J. J. Cherwinka,
T. Classen,
K. Commeford,
A. Conant,
D. Davee,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
B. Hackett,
K. Han
, et al. (41 additional authors not shown)
Abstract:
This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source a…
▽ More
This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the $^{6}$Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850$\pm$20 PE/MeV, an energy resolution of $σ$ = 4.0$\pm$0.2% at 1 MeV, and efficient pulse-shape discrimination of low $dE/dx$ (electronic recoil) and high $dE/dx$ (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85$\pm$3 cm is measured in each segment. The 0.1% by mass concentration of $^{6}$Li in the scintillator results in a measured neutron capture time of $τ$ = 42.8$\pm$0.2 $μs$. The long-term stability of the scintillator is also discussed. The detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.
△ Less
Submitted 29 June, 2018; v1 submitted 23 May, 2018;
originally announced May 2018.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
Project 8 detector upgrades for a tritium beta decay spectrum using cyclotron radiation
Authors:
A Ashtari Esfahani,
S Böser,
C Claessens,
L de Viveiros,
P J Doe,
S Doeleman,
M Fertl,
E C Finn,
J A Formaggio,
M Guigue,
K M Heeger,
A M Jones,
K Kazkaz,
B H LaRoque,
E Machado,
B Monreal,
J A Nikkel,
N S Oblath,
R G H Robertson,
L J Rosenberg,
G Rybka,
L Saldaña,
P L Slocum,
J R Tedeschi,
T Thümmler
, et al. (5 additional authors not shown)
Abstract:
Following the successful observation of single conversion electrons from $^{83m}$Kr using Cyclotron Radiation Emission Spectroscopy (CRES), Project 8 is now advancing its focus toward a tritium beta decay spectrum. A tritium spectrum will be an important next step toward a direct measurement of the neutrino mass for Project 8. Here we discuss recent progress on the development and commissioning of…
▽ More
Following the successful observation of single conversion electrons from $^{83m}$Kr using Cyclotron Radiation Emission Spectroscopy (CRES), Project 8 is now advancing its focus toward a tritium beta decay spectrum. A tritium spectrum will be an important next step toward a direct measurement of the neutrino mass for Project 8. Here we discuss recent progress on the development and commissioning of a new gas cell for use with tritium, and outline the primary goals of the experiment for the near future.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Results from the Project 8 phase-1 cyclotron radiation emission spectroscopy detector
Authors:
A Ashtari Esfahani,
S Böser,
C Claessens,
L de Viveiros,
P J Doe,
S Doeleman,
M Fertl,
E C Finn,
J A Formaggio,
M Guigue,
K M Heeger,
A M Jones,
K Kazkaz,
B H LaRoque,
E Machado,
B Monreal,
J A Nikkel,
N S Oblath,
R G H Robertson,
L J Rosenberg,
G Rybka,
L Saldaña,
P L Slocum,
J R Tedeschi,
T Thümmler
, et al. (5 additional authors not shown)
Abstract:
The Project 8 collaboration seeks to measure the absolute neutrino mass scale by means of precision spectroscopy of the beta decay of tritium. Our technique, cyclotron radiation emission spectroscopy, measures the frequency of the radiation emitted by electrons produced by decays in an ambient magnetic field. Because the cyclotron frequency is inversely proportional to the electron's Lorentz facto…
▽ More
The Project 8 collaboration seeks to measure the absolute neutrino mass scale by means of precision spectroscopy of the beta decay of tritium. Our technique, cyclotron radiation emission spectroscopy, measures the frequency of the radiation emitted by electrons produced by decays in an ambient magnetic field. Because the cyclotron frequency is inversely proportional to the electron's Lorentz factor, this is also a measurement of the electron's energy. In order to demonstrate the viability of this technique, we have assembled and successfully operated a prototype system, which uses a rectangular waveguide to collect the cyclotron radiation from internal conversion electrons emitted from a gaseous $^{83m}$Kr source. Here we present the main design aspects of the first phase prototype, which was operated during parts of 2014 and 2015. We will also discuss the procedures used to analyze these data, along with the features which have been observed and the performance achieved to date.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Project 8 Phase III Design Concept
Authors:
A Ashtari Esfahani,
S Böser,
C Claessens,
L de Viveiros,
P J Doe,
S Doeleman,
M Fertl,
E C Finn,
J A Formaggio,
M Guigue,
K M Heeger,
A M Jones,
K Kazkaz,
B H LaRoque,
E Machado,
B Monreal,
J A Nikkel,
N S Oblath,
R G H Robertson,
L J Rosenberg,
G Rybka,
L Saldaña,
P L Slocum,
J R Tedeschi,
T Thümmler
, et al. (5 additional authors not shown)
Abstract:
We present a working concept for Phase III of the Project 8 experiment, aiming to achieve a neutrino mass sensitivity of $2~\mathrm{eV}$ ($90~\%$ C.L.) using a large volume of molecular tritium and a phased antenna array. The detection system is discussed in detail.
We present a working concept for Phase III of the Project 8 experiment, aiming to achieve a neutrino mass sensitivity of $2~\mathrm{eV}$ ($90~\%$ C.L.) using a large volume of molecular tritium and a phased antenna array. The detection system is discussed in detail.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Determining the neutrino mass with Cyclotron Radiation Emission Spectroscopy - Project 8
Authors:
Ali Ashtari Esfahani,
David M. Asner,
Sebastian Böser,
Raphael Cervantes,
Christine Claessens,
Luiz de Viveiros,
Peter J. Doe,
Shepard Doeleman,
Justin L. Fernandes,
Martin Fertl,
Erin C. Finn,
Joseph A. Formaggio,
Daniel Furse,
Mathieu Guigue,
Karsten M. Heeger,
A. Mark Jones,
Kareem Kazkaz,
Jared A. Kofron,
Callum Lamb,
Benjamin H. LaRoque,
Eric Machado,
Elizabeth L. McBride,
Michael L. Miller,
Benjamin Monreal,
Prajwal Mohanmurthy
, et al. (19 additional authors not shown)
Abstract:
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(ν_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observati…
▽ More
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(ν_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observations of neutrino oscillations, while the KATRIN Experiment - the current-generation tritium beta-decay experiment that is based on Magnetic Adiabatic Collimation with an Electrostatic (MAC-E) filter - will achieve a sensitivity of $m(ν_e) \lesssim 0.2\,{\rm eV}$. The CRES technique aims to avoid the difficulties in scaling up a MAC-E filter-based experiment to achieve a lower mass sensitivity. In this paper we review the current status of the CRES technique and describe Project 8, a phased absolute neutrino mass experiment that has the potential to reach sensitivities down to $m(ν_e) \lesssim 40\,{\rm meV}$ using an atomic tritium source.
△ Less
Submitted 6 March, 2017;
originally announced March 2017.
-
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
I. J. Arnquist,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. Bolozdynya,
B. Boxer,
R. Bramante,
P. Brás,
J. H. Buckley,
V. V. Bugaev
, et al. (180 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,…
▽ More
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
△ Less
Submitted 26 September, 2017; v1 submitted 8 February, 2017;
originally announced February 2017.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
Index of refraction, Rayleigh scattering length, and Sellmeier coefficients in solid and liquid argon and xenon
Authors:
Emily Grace,
Alistair Butcher,
Jocelyn Monroe,
James A. Nikkel
Abstract:
Large liquid argon detectors have become widely used in low rate experiments, including dark matter and neutrino research. However, the optical properties of liquid argon are not well understood at the large scales relevant for current and near-future detectors.The index of refraction of liquid argon at the scin- tillation wavelength has not been measured, and current Rayleigh scattering length ca…
▽ More
Large liquid argon detectors have become widely used in low rate experiments, including dark matter and neutrino research. However, the optical properties of liquid argon are not well understood at the large scales relevant for current and near-future detectors.The index of refraction of liquid argon at the scin- tillation wavelength has not been measured, and current Rayleigh scattering length calculations disagree with measurements. Furthermore, the Rayleigh scattering length and index of refraction of solid argon and solid xenon at their scintillation wavelengths have not been previously measured or calculated. We introduce a new calculation using existing data in liquid and solid argon and xenon to extrapolate the optical properties at the scintillation wavelengths using the Sellmeier dispersion relationship.
△ Less
Submitted 11 August, 2017; v1 submitted 14 February, 2015;
originally announced February 2015.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping
Authors:
Christopher G. Wahl,
Ethan P. Bernard,
W. Hugh Lippincott,
James A. Nikkel,
Yunchang Shin,
Daniel N. McKinsey
Abstract:
Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in light or signal yield, energy resolution, and particle discrimination. In this study, we investigate the detector response for xenon dopant concentrations from…
▽ More
Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in light or signal yield, energy resolution, and particle discrimination. In this study, we investigate the detector response for xenon dopant concentrations from 9 +/- 5 ppm to 1100 +/- 500 ppm xenon (by weight) in 6 steps. The 3.14-liter detector uses tetraphenyl butadiene (TPB) wavelength shifter with dual photomultiplier tubes and is operated in single-phase mode. Gamma-ray-interaction signal yield of 4.0 +/- 0.1 photoelectrons/keV improved to 5.0 +/- 0.1 photoelectrons/keV with dopant. Energy resolution at 662 keV improved from (4.4 +/- 0.2)% (σ) to (3.5 +/- 0.2)% (σ) with dopant. Pulse-shape discrimination performance degraded greatly at the first addition of dopant, slightly improved with additional additions, then rapidly improved near the end of our dopant range, with performance becoming slightly better than pure argon at the highest tested dopant concentration. Some evidence of reduced neutron scintillation efficiency with increasing dopant concentration was observed. Finally, the waveform shape outside the TPB region is discussed, suggesting that the contribution to the waveform from xenon-produced light is primarily in the last portion of the slow component.
△ Less
Submitted 20 April, 2014; v1 submitted 3 March, 2014;
originally announced March 2014.
-
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
K. Clark,
T. Coffey,
A. Currie,
A. Curioni,
S. Dazeley,
L. de Viveiros,
A. Dobi
, et al. (78 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li…
▽ More
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
△ Less
Submitted 5 February, 2014; v1 submitted 30 October, 2013;
originally announced October 2013.
-
The Large Underground Xenon (LUX) Experiment
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
C. Camp,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
A. Chiller,
C. Chiller,
K. Clark,
T. Classen,
T. Coffey,
A. Curioni,
E. Dahl,
S. Dazeley,
L. de Viveiros,
A. Dobi,
E. Dragowsky,
E. Druszkiewicz
, et al. (69 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100…
▽ More
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100 kg/month in the inner 100-kg fiducial volume (FV) of the 370-kg detector. The overall background goals are set to have $<$1 background events characterized as possible WIMPs in the FV in 300 days of running.
This paper describes the design and construction of the LUX detector.
△ Less
Submitted 21 November, 2012; v1 submitted 15 November, 2012;
originally announced November 2012.
-
Technical Results from the Surface Run of the LUX Dark Matter Experiment
Authors:
LUX Collaboration,
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
J. J. Chapman,
T. Coffey,
A. Dobi,
E. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
M. Gilchriese,
C. Hall,
M. Hanhardt,
M. Ihm,
R. G. Jacobsen,
L. Kastens
, et al. (42 additional authors not shown)
Abstract:
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed i…
▽ More
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed in a water tank, validated the integration of the various sub-systems in preparation of the underground deployment. Using the data collected, we report excellent light collection properties, achieving 8.4 photoelectrons per keV for 662 keV electron recoils without an applied electric field, measured in the center of the WIMP target. We also find good energy and position resolution in relatively high-energy interactions from a variety of internal and external sources. Finally, we have used the commissioning data to tune the optical properties of our simulation and report updated sensitivity projections for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 22 February, 2013; v1 submitted 16 October, 2012;
originally announced October 2012.
-
An Ultra-Low Background PMT for Liquid Xenon Detectors
Authors:
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
Y-D. Chan,
K. Clark,
T. Coffey,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook,
M. Ihm
, et al. (42 additional authors not shown)
Abstract:
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other det…
▽ More
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
△ Less
Submitted 24 June, 2013; v1 submitted 10 May, 2012;
originally announced May 2012.
-
Radio-assay of Titanium samples for the LUX Experiment
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
Y-D. Chan,
K. Clark,
T. Classen,
T. Coffey,
S. Dazeley,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook
, et al. (41 additional authors not shown)
Abstract:
We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample w…
▽ More
We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample with the lowest total long-lived activity was measured to contain <0.25 mBq/kg of U-238, <0.2 mBq/kg of Th-232, and <1.2 mBq/kg of K-40. Measurements of several samples also indicated the presence of short-lived (84 day half life) Sc-46, likely produced cosmogenically via muon initiated (n,p) reactions.
△ Less
Submitted 12 February, 2012; v1 submitted 6 December, 2011;
originally announced December 2011.
-
Scintillation yield and time dependence from electronic and nuclear recoils in liquid neon
Authors:
W. H. Lippincott,
K. J. Coakley,
D. Gastler,
E. Kearns,
D. N. McKinsey,
J. A. Nikkel
Abstract:
We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear recoil energy. We also measure the \leff\, parameter in liquid neon between 30 and 370 keV nuclear recoil energ…
▽ More
We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear recoil energy. We also measure the \leff\, parameter in liquid neon between 30 and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50 keV. We observe a dependence of the scintillation time distribution and signal yield on the pressure and temperature of the liquid neon.
△ Less
Submitted 13 August, 2012; v1 submitted 14 November, 2011;
originally announced November 2011.
-
LUXSim: A Component-Centric Approach to Low-Background Simulations
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
T. Coffey,
S. Dazeley,
L. de Viveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook,
M. Ihm
, et al. (38 additional authors not shown)
Abstract:
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpo…
▽ More
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpoint, there is no single source or beam, but rather a collection of sources with potentially complicated spatial extent. LUXSim is a simulation framework used by the LUX collaboration that takes a component-centric approach to event generation and recording. A new set of classes allows for multiple radioactive sources to be set within any number of components at run time, with the entire collection of sources handled within a single simulation run. Various levels of information can also be recorded from the individual components, with these record levels also being set at runtime. This flexibility in both source generation and information recording is possible without the need to recompile, reducing the complexity of code management and the proliferation of versions. Within the code itself, casting geometry objects within this new set of classes rather than as the default Geant4 classes automatically extends this flexibility to every individual component. No additional work is required on the part of the developer, reducing development time and increasing confidence in the results. We describe the guiding principles behind LUXSim, detail some of its unique classes and methods, and give examples of usage.
* Corresponding author, kareem@llnl.gov
△ Less
Submitted 8 November, 2011;
originally announced November 2011.
-
Scintillation and charge extraction from the tracks of energetic electrons in superfluid helium-4
Authors:
W. Guo,
M. Dufault,
S. B. Cahn,
J. A. Nikkel,
Y. Shin,
D. N. McKinsey
Abstract:
An energetic electron passing through liquid helium causes ionization along its track. The ionized electrons quickly recombine with the resulting positive ions, which leads to the production of prompt scintillation light. By applying appropriate electric fields, some of the ionized electrons can be separated from their parent ions. The fraction of the ionized electrons extracted in a given applied…
▽ More
An energetic electron passing through liquid helium causes ionization along its track. The ionized electrons quickly recombine with the resulting positive ions, which leads to the production of prompt scintillation light. By applying appropriate electric fields, some of the ionized electrons can be separated from their parent ions. The fraction of the ionized electrons extracted in a given applied field depends on the separation distance between the electrons and the ions. We report the determination of the mean electron-ion separation distance for charge pairs produced along the tracks of beta particles in superfluid helium at 1.5 K by studying the quenching of the scintillation light under applied electric fields. Knowledge of this mean separation parameter will aid in the design of particle detectors that use superfluid helium as a target material.
△ Less
Submitted 26 September, 2011;
originally announced September 2011.
-
Visualization study of counterflow in superfluid helium-4 using metastable helium molecules
Authors:
Wei Guo,
Sidney B. Cahn,
James A. Nikkel,
William F. Vinen,
Daniel N. McKinsey
Abstract:
Heat is carried in superfluid He-4 by the motion of the normal fluid$^{1}$, a counterflowing superfluid component serving to eliminate any net mass flow. It has been known for many years that above a critical heat current the superfluid component in this counterflow becomes turbulent. This turbulence takes the form of a disorganized tangle of quantized vortex lines and is maintained by the relativ…
▽ More
Heat is carried in superfluid He-4 by the motion of the normal fluid$^{1}$, a counterflowing superfluid component serving to eliminate any net mass flow. It has been known for many years that above a critical heat current the superfluid component in this counterflow becomes turbulent. This turbulence takes the form of a disorganized tangle of quantized vortex lines and is maintained by the relative motion of the two fluids$^{2-3}$. It has been suspected that the normal fluid may also become turbulent$^{4}$, but experimental verification is difficult without a technique for visualizing the flow. Here we report a series of visualization studies on the normal-fluid component in a thermal counterflow performed by imaging the motion of seeded metastable helium molecules using a laser-induced-fluorescence technique$^{5-8}$. We present evidence that the flow of the normal fluid is indeed turbulent, at least at relatively large velocities. Thermal counterflow in which both components are turbulent presents us with a new and theoretically challenging type of turbulent behaviour.
△ Less
Submitted 14 April, 2010;
originally announced April 2010.
-
Measurement of scintillation efficiency for nuclear recoils in liquid argon
Authors:
D. Gastler,
E. Kearns,
A. Hime,
L. C. Stonehill,
S. Seibert,
J. Klein,
W. H. Lippincott,
D. N. McKinsey,
J. A. Nikkel
Abstract:
The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
△ Less
Submitted 8 May, 2012; v1 submitted 2 April, 2010;
originally announced April 2010.
-
Studying the normal-fluid flow in Helium-II using metastable helium molecules
Authors:
W. Guo,
J. D. Wright,
S. B. Cahn,
J. A. Nikkel,
D. N. McKinsey
Abstract:
We demonstrate that metastable helium molecules can be used as tracers to visualize the flow of the normal fluid in superfluid $^{4}$He using a laser-induced-fluorescence technique. The flow pattern of a normal-fluid jet impinging on the center of a copper disc is imaged. A ring-shaped circulation structure of the normal fluid is observed as the jet passes across the disc surface. The fluorescen…
▽ More
We demonstrate that metastable helium molecules can be used as tracers to visualize the flow of the normal fluid in superfluid $^{4}$He using a laser-induced-fluorescence technique. The flow pattern of a normal-fluid jet impinging on the center of a copper disc is imaged. A ring-shaped circulation structure of the normal fluid is observed as the jet passes across the disc surface. The fluorescence signal for the molecules trapped in the circulation structure is measured as a function of time after we turn off the molecule source. The radiative lifetime and density of the molecules can be determined by fitting the measured data using a simple analytic model. We also discuss a proposed experiment on using a previously developed molecule tagging-imaging technique to visualize the normal-fluid velocity profile during the transition of quantum turbulence in a thermal counterflow channel.
△ Less
Submitted 11 October, 2009;
originally announced October 2009.
-
Metastable helium molecules as tracers in superfluid liquid $^{4}$He
Authors:
W. Guo,
J. D. Wright,
S. B. Cahn,
J. A. Nikkel,
D. N. McKinsey
Abstract:
Metastable helium molecules generated in a discharge near a sharp tungsten tip operated in either pulsed mode or continuous field-emission mode in superfluid liquid $^{4}$He are imaged using a laser-induced-fluorescence technique. By pulsing the tip, a small cloud of He$_{2}^{*}$ molecules is produced. At 2.0 K, the molecules in the liquid follow the motion of the normal fluid. We can determine…
▽ More
Metastable helium molecules generated in a discharge near a sharp tungsten tip operated in either pulsed mode or continuous field-emission mode in superfluid liquid $^{4}$He are imaged using a laser-induced-fluorescence technique. By pulsing the tip, a small cloud of He$_{2}^{*}$ molecules is produced. At 2.0 K, the molecules in the liquid follow the motion of the normal fluid. We can determine the normal-fluid velocity in a heat-induced counterflow by tracing the position of a single molecule cloud. As we run the tip in continuous field-emission mode, a normal-fluid jet from the tip is generated and molecules are entrained in the jet. A focused 910 nm pump laser pulse is used to drive a small group of molecules to the vibrational $a(1)$ state. Subsequent imaging of the tagged $a(1)$ molecules with an expanded 925 nm probe laser pulse allows us to measure the velocity of the normal fluid. The techniques we developed demonstrate for the first time the ability to trace the normal-fluid component in superfluid helium using angstrom-sized particles.
△ Less
Submitted 9 April, 2009; v1 submitted 4 April, 2009;
originally announced April 2009.
-
Detection and Imaging of He_2 Molecules in Superfluid Helium
Authors:
W. G. Rellergert,
S. B. Cahn,
A. Garvan,
J. C. Hanson,
W. H. Lippincott,
J. A. Nikkel,
D. N. McKinsey
Abstract:
We present data that show a cycling transition can be used to detect and image metastable He$_2$ triplet molecules in superfluid helium. We demonstrate that limitations on the cycling efficiency due to the vibrational structure of the molecule can be mitigated by the use of repumping lasers. Images of the molecules obtained using the method are also shown. This technique gives rise to a new kind…
▽ More
We present data that show a cycling transition can be used to detect and image metastable He$_2$ triplet molecules in superfluid helium. We demonstrate that limitations on the cycling efficiency due to the vibrational structure of the molecule can be mitigated by the use of repumping lasers. Images of the molecules obtained using the method are also shown. This technique gives rise to a new kind of ionizing radiation detector. The use of He$_2$ triplet molecules as tracer particles in the superfluid promises to be a powerful tool for visualization of both quantum and classical turbulence in liquid helium.
△ Less
Submitted 18 December, 2007; v1 submitted 12 September, 2007;
originally announced September 2007.