-
Application of the Most Frequent Value Method for $^{39}$Ar Half-Life Determination
Authors:
Victor V. Golovko
Abstract:
An evaluation method supported by robust statistical analysis was used to analyze historical measurements of $^{39}$Ar half-life. The method, which combines the most frequent value (MFV) approach with bootstrap analysis, provides a more reliable way to estimate the half-life of $^{39}$Ar. The results show that the half-life is T1/2(MFV) = 268.2 + (3.1) - (2.9) years, with an uncertainty correspond…
▽ More
An evaluation method supported by robust statistical analysis was used to analyze historical measurements of $^{39}$Ar half-life. The method, which combines the most frequent value (MFV) approach with bootstrap analysis, provides a more reliable way to estimate the half-life of $^{39}$Ar. The results show that the half-life is T1/2(MFV) = 268.2 + (3.1) - (2.9) years, with an uncertainty corresponding to the 68% confidence level. This uncertainty is three times smaller than the most precise re-calculated measurements by Stoenner et al. (1965) and 2.7 times smaller than the adopted half-life value in nuclear data sheets. Recently, the specific activity of the beta decay of $^{39}$Ar in atmospheric argon was measured in various underground facilities. Applying the MFV method to these measurements gives a specific activity of SA($^{39}$Ar/Ar)(MFV) = 0.966 + (0.010) - (0.018) Bq/kg(atmAr), with an uncertainty corresponding to the 68% confidence level. This paper also discusses the method used to determine the half-life of $^{39}$Ar using the specific activity of $^{39}$Ar in atmospheric argon.
△ Less
Submitted 6 October, 2023;
originally announced October 2023.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Ambient Dose and Dose Rate Measurement in SNOLAB Underground Laboratory at Sudbury, Ontario, Canada
Authors:
Victor V. Golovko,
Oleg Kamaev,
Jiansheng Sun,
Chris J. Jillings,
Pierre Gorel,
Eric Vazquez-Jauregui
Abstract:
The paper describes a system and experimental procedure that use integrating passive detectors, such as thermoluminescent dosimeters (TLDs), for the measurement of ultra-low-level ambient dose equivalent rate values at the underground SNOLAB facility located in Sudbury, Ontario, Canada. Because these detectors are passive and can be exposed for relatively long periods of time, they can provide bet…
▽ More
The paper describes a system and experimental procedure that use integrating passive detectors, such as thermoluminescent dosimeters (TLDs), for the measurement of ultra-low-level ambient dose equivalent rate values at the underground SNOLAB facility located in Sudbury, Ontario, Canada. Because these detectors are passive and can be exposed for relatively long periods of time, they can provide better sensitivity for measuring ultra-low activity levels. The final characterization of ultra-low-level ambient dose around water shielding for ongoing direct dark matter search experiments in Cube Hall at SNOLAB underground laboratory is given. The conclusion is that TLDs provide reliable results in the measurement of the ultra-low-level environmental radiation background.
△ Less
Submitted 28 March, 2024; v1 submitted 9 February, 2023;
originally announced February 2023.
-
Simplified Efficiency Calibration Methods for Semiconductor Detectors used in Criticality Dosimetry
Authors:
Victor V. Golovko
Abstract:
``Oversimplified'' and ``simplified'' methods based on true coincidence summing effect used in uncomplicated determination of the photo-peak efficiency of the semiconductor High Purity Germanium (HPGe) detector system are suggested and verified. The methods and calibrated $^{60}$Co radioactive source may be used to commission any HPGe detector to use during potential criticality event. The determi…
▽ More
``Oversimplified'' and ``simplified'' methods based on true coincidence summing effect used in uncomplicated determination of the photo-peak efficiency of the semiconductor High Purity Germanium (HPGe) detector system are suggested and verified. The methods and calibrated $^{60}$Co radioactive source may be used to commission any HPGe detector to use during potential criticality event. The determined accuracy of the semiconductor HPGe detector system using this method is a few percent (for the detector system used in this study it was $\simeq$8\% for oversimplified and $\simeq$5\% for simplified methods accordingly) reasonable, expected, and good enough to use for estimation of neutron dose from irradiated human blood in a potential criticality event. Moreover, if one can experimentally deduce the photo-peak efficiency for $^{60}$Co 1333 keV $γ$-ray line using the suggested methods, then with a few percent accuracy this efficiency could be also used for 1369 keV $γ$-ray line in the decay of $^{24}$Na isotope.
△ Less
Submitted 20 June, 2022;
originally announced June 2022.
-
The liquid-argon scintillation pulseshape in DEAP-3600
Authors:
The DEAP collaboration,
P. Adhikari,
R. Ajaj,
G. R. Araujoand M. Batygov,
B. Beltran,
C. E. Bina,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. J. Daughertyand K. Dering,
L. Doria,
F. A. Duncan andM. Dunford,
A. Erlandson,
N. Fatemighomi,
G. Fiorillo,
A. Flower,
R. J. Ford,
R. Gagnon
, et al. (76 additional authors not shown)
Abstract:
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed…
▽ More
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed here is the basis of PSD.
The observed pulseshape is a combination of LAr scintillation physics with detector effects. We present a model for the pulseshape of electromagnetic background events in the energy region of interest for dark matter searches. The model is composed of a) LAr scintillation physics, including the so-called intermediate component, b) the time response of the TPB wavelength shifter, including delayed TPB emission at $\mathcal O$(ms) time-scales, and c) PMT response.
TPB is the wavelength shifter of choice in most LAr detectors. We find that approximately 10\% of the intensity of the wavelength-shifted light is in a long-lived state of TPB. This causes light from an event to spill into subsequent events to an extent not usually accounted for in the design and data analysis of LAr-based detectors.
△ Less
Submitted 8 June, 2020; v1 submitted 27 January, 2020;
originally announced January 2020.
-
In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment
Authors:
DEAP Collaboration,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
S. Churchwell,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
S. Dittmeier,
F. A. Duncan,
M. Dunford,
A. Erlandson
, et al. (77 additional authors not shown)
Abstract:
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed.
We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detaile…
▽ More
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed.
We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.
△ Less
Submitted 29 January, 2019; v1 submitted 29 May, 2017;
originally announced May 2017.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Authors:
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
K. Boudjemline,
M. G. Boulay B. Cai T. Caldwell,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Contreras,
K. Dering,
F. Duncan,
R. Ford,
R. Gagnon F. Giuliani,
M. Gold V. V. Golovko,
P. Gorel,
K. Graham,
D. R. Grant,
R. Hakobyan,
A. L. Hallin,
P. Harvey,
C. Hearns,
C. J. Jillings,
M. Kuźniak,
I. Lawson,
O. Li
, et al. (27 additional authors not shown)
Abstract:
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.…
▽ More
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.
△ Less
Submitted 23 April, 2014; v1 submitted 5 November, 2012;
originally announced November 2012.