Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–8 of 8 results for author: Buck, B

Searching in archive physics. Search in all archives.
.
  1. arXiv:2311.08591  [pdf, other

    physics.flu-dyn physics.comp-ph

    A Two-Field Formulation for Surfactant Transport within the Algebraic Volume of Fluid Method

    Authors: T. Antritter, T. Josyula, T. Marić, D. Bothe, P. Hachmann, B. Buck, T. Gambaryan-Roisman, P. Stephan

    Abstract: Surfactant transport plays an important role in many technical processes and industrial applications such as chemical reactors, microfluidics, printing and coating technology. High fidelity numerical simulations of two-phase flow phenomena reveal rich insights into the flow dynamics, heat, mass and species transport. In the present study, a two-field formulation for surfactant transport within the… ▽ More

    Submitted 14 November, 2023; originally announced November 2023.

  2. arXiv:1412.4769  [pdf, other

    physics.ins-det hep-ex

    Cosmic Ray Test of Mini-drift Thick Gas Electron Multiplier Chamber for Transition Radiation Detector

    Authors: S. Yang, S. Das, B. Buck, C. Li, T. Ljubicic, R. Majka, M. Shao, N. Smirnov, G. Visser, Z. Xu, Y. Zhou

    Abstract: A thick gas electron multiplier (THGEM) chamber with an effective readout area of 10$\times$10 cm$^{2}$ and a 11.3 mm ionization gap has been tested along with two regular gas electron multiplier (GEM) chambers in a cosmic ray test system. The thick ionization gap makes the THGEM chamber a mini-drift chamber. This kind mini-drift THGEM chamber is proposed as part of a transition radiation detector… ▽ More

    Submitted 17 February, 2015; v1 submitted 14 December, 2014; originally announced December 2014.

    Comments: 16 pages, 14 figures

    Journal ref: Nucl. Instr. and Meth. A 785 (2015) 33-39

  3. arXiv:1408.1914  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

    Authors: M. Akashi-Ronquest, P. -A. Amaudruz, M. Batygov, B. Beltran, M. Bodmer, M. G. Boulay, B. Broerman, B. Buck, A. Butcher, B. Cai, T. Caldwell, M. Chen, Y. Chen, B. Cleveland, K. Coakley, K. Dering, F. A. Duncan, J. A. Formaggio, R. Gagnon, D. Gastler, F. Giuliani, M. Gold, V. V. Golovko, P. Gorel, K. Graham , et al. (57 additional authors not shown)

    Abstract: Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We… ▽ More

    Submitted 12 December, 2014; v1 submitted 8 August, 2014; originally announced August 2014.

    Comments: 16 pages, 16 figures

  4. arXiv:1404.0993  [pdf, other

    physics.ins-det

    Design and Fabrication of a Highly Integrated Silicon Detector for the STAR Experiment at Brookhaven National Laboratory

    Authors: Benjamin Buck, Eric Anderssen, Jason Bessuille, Mario Cepeda, Thomas Johnson, James Kelsey, Gerrit van Nieuwenhuizen, Gerard Visser

    Abstract: We present the design of a detector used as a particle tracking device in the STAR experiment at the RHIC collider of Brookhaven National Laboratories. The "stave," 24 of which make up the completed detector, is a highly mechanically integrated design comprised of 6 custom silicon sensors mounted on a Kapton substrate. 4608 wire bonds connect these sensors to 36 analog front-end chips which are mo… ▽ More

    Submitted 3 April, 2014; originally announced April 2014.

    Comments: 14 Pages, 17 Figures. Submitted to New England iMAPS 2014 Symposium and Expo

  5. arXiv:1403.4842  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Update on the MiniCLEAN Dark Matter Experiment

    Authors: K. Rielage, M. Akashi-Ronquest, M. Bodmer, R. Bourque, B. Buck, A. Butcher, T. Caldwell, Y. Chen, K. Coakley, E. Flores, J. A. Formaggio, D. Gastler, F. Giuliani, M. Gold, E. Grace, J. Griego, N. Guerrero, V. Guiseppe, R. Henning, A. Hime, S. Jaditz, C. Kachulis, E. Kearns, J. Kelsey, J. R. Klein , et al. (21 additional authors not shown)

    Abstract: The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o… ▽ More

    Submitted 19 March, 2014; originally announced March 2014.

    Comments: To appear in the Proceedings of the TAUP 2013 Conference (F. Avignone & W. Haxton, editors, Physics Procedia, Elsevier)

    Report number: LA-UR-14-21626

  6. Design of the MiniCLEAN dark matter search veto detector subsystem

    Authors: Robert Abruzzio, Benjamin Buck, Stephen Jaditz, James Kelsey, Jocelyn Monroe, Kimberyl Palladino

    Abstract: This paper describes the design of the active muon veto subsystem for the MiniCLEAN dark matter direct detection experiment at SNOLAB in Sudbury, Ontario, Canada. The water-filled veto is instrumented with 48 PMTs which are read out by front end electronics to time multiplex 48 photomultiplier channels into 6 digitizer channels and provide an instantaneous hit sum across the subsystem (N-Hit) for… ▽ More

    Submitted 6 March, 2014; originally announced March 2014.

    Comments: 11 Pages

  7. arXiv:1312.1730  [pdf, other

    physics.ins-det nucl-ex

    The OLYMPUS Experiment

    Authors: R. Milner, D. K. Hasell, M. Kohl, U. Schneekloth, N. Akopov, R. Alarcon, V. A. Andreev, O. Ates, A. Avetisyan, D. Bayadilov, R. Beck, S. Belostotski, J. C. Bernauer, J. Bessuille, F. Brinker, B. Buck, J. R. Calarco, V. Carassiti, E. Cisbani, G. Ciullo, M. Contalbrigo, N. D'Ascenzo, R. De Leo, J. Diefenbach, T. W. Donnelly , et al. (48 additional authors not shown)

    Abstract: The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and… ▽ More

    Submitted 5 December, 2013; originally announced December 2013.

    Comments: 40 pages, 26 figures

    Journal ref: Nuclear Inst. and Methods in Physics Research, A (2014) pp. 1-17

  8. arXiv:1307.4432  [pdf, other

    physics.ins-det hep-ex

    DarkLight: A Search for Dark Forces at the Jefferson Laboratory Free-Electron Laser Facility

    Authors: J. Balewski, J. Bernauer, W. Bertozzi, J. Bessuille, B. Buck, R. Cowan, K. Dow, C. Epstein, P. Fisher, S. Gilad, E. Ihloff, Y. Kahn, A. Kelleher, J. Kelsey, R. Milner, C. Moran, L. Ou, R. Russell, B. Schmookler, J. Thaler, C. Tschalär, C. Vidal, A. Winnebeck, S. Benson, C. Gould , et al. (42 additional authors not shown)

    Abstract: We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.

    Submitted 19 July, 2013; v1 submitted 16 July, 2013; originally announced July 2013.

    Comments: 8 pages, 4 figures, contributed to the Community Summer Study 2013 "Snowmass on the Mississippi" in the New, Light, Weakly Coupled Particles (NLWCP) subgroup of the Intensity Frontier