Time-Of-Flight methodologies with large-area diamond detectors for ion characterization in laser-driven experiments
Authors:
M. Salvadori,
G. Di Giorgio,
M. Cipriani,
C. Verona,
P. L. Andreoli,
G. Cristofari,
R. De Angelis,
M. Pillon,
N. E. Andreev,
P. Antici,
N. G. Borisenko,
D. Giulietti,
M. Migliorati,
O. Rosmej,
S. Zahter,
F. Consoli
Abstract:
Time-Of-Flight (TOF) technique coupled with semiconductor detectors is a powerful instrument to provide real-time characterization of ions accelerated because of laser-matter interactions. Nevertheless, the presence of strong electromagnetic pulses (EMPs) generated during the interactions, can severely hinder its employment. For this reason, the diagnostic system must be designed to have high EMP…
▽ More
Time-Of-Flight (TOF) technique coupled with semiconductor detectors is a powerful instrument to provide real-time characterization of ions accelerated because of laser-matter interactions. Nevertheless, the presence of strong electromagnetic pulses (EMPs) generated during the interactions, can severely hinder its employment. For this reason, the diagnostic system must be designed to have high EMP shielding. Here we present a new advanced prototype of detector, developed at ENEA-Centro Ricerche Frascati (Italy), with a large area (15 mm x 15 mm) polycrystalline diamond sensor having 150 microns thickness. The tailored detector design and testing ensure high sensitivity and, thanks to the fast temporal response, high energy resolution of the reconstructed ion spectrum. The detector was offline calibrated and then successfully tested during an experimental campaign carried out at the PHELIX laser facility at GSI (Germany). The high rejection to EMP fields was demonstrated and suitable calibrated spectra of the accelerated protons were obtained.
△ Less
Submitted 29 October, 2021;
originally announced October 2021.
-
uRANIA-V: an innovative solution for neutron detection in homeland security
Authors:
R. Farinelli,
I. Balossino,
G. Bencivenni,
G. Cibinetto,
G. Felici,
S. Fiore,
I. Garzia,
M. Gatta,
M. Giovannetti,
R. Hall-Wilton,
C. C. Lai,
L. Lavezzi,
G. Mezzadri,
G. Morello,
E. Paoletti,
G. Papalino,
A. Pietropaolo,
M. Pillon,
M. Poli Lener,
L. Robinson,
M. Scodeggio,
P. O. Svensson
Abstract:
Detection of neutrons is becoming of the utmost importance, especially in the studies of radioactive waste and in homeland security applications. The crisis of 3He availability has required the development of innovative techniques. One solution is to develop light gas detectors for neutron counting to be used as portals for ports and airports. The neutron is converted on the Boron-coated cathode,…
▽ More
Detection of neutrons is becoming of the utmost importance, especially in the studies of radioactive waste and in homeland security applications. The crisis of 3He availability has required the development of innovative techniques. One solution is to develop light gas detectors for neutron counting to be used as portals for ports and airports. The neutron is converted on the Boron-coated cathode, releasing a charged particle, whose passage can be identified by the gas detector. While several technologies have been deployed in the past, the project μRANIA-V ( μRwell Advanced Neutron Identification Apparatus) aims to detect thermal neutrons by means of the μRwell technology, an innovative gas detector. The goal is to produce tiles to operate as portals in homeland security or for radioactive waste management. The technological transfer towards the industry has started, thus the production can be cost-effective also owing to a construction process relatively easier compared to similar apparatus. By reading directly the signals from the amplification stage, the neutrons can be counted with simplified electronics further reducing the total cost. In this paper, the project will be described, with details on the μRwell technology and on the neutron counting, on the test beam performed, and on the future plans.
△ Less
Submitted 2 September, 2021;
originally announced September 2021.
-
Radiation study of Lead Fluoride crystals
Authors:
A. Cemmi,
A. Colangeli,
B. D'orsi,
I. Di Sarcina,
E. Diociaiuti,
S. Fiore,
D. Paesani,
M. Pillon,
A. Saputi,
I. Sarra,
D. Tagnani
Abstract:
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total…
▽ More
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total fluence. Their loss in transmittance was evaluated at different steps of the photon and neutron irradiation campaign, resulting in a total of 30% loss above 350 nm. With crystals always kept in dark conditions, natural and thermal annealing, as well as optical bleaching with 400 nm light, were performed on the irradiated specimens, resulting in a partial recovery of their original optical characteristics.
△ Less
Submitted 14 April, 2022; v1 submitted 26 July, 2021;
originally announced July 2021.
-
Minimum amount of energy required for the transference of electrons between atoms
Authors:
Matheus Barbiero Pillon
Abstract:
The purpose of this article is to show a different way to calculate the electron transfer between atoms. It can be used as a base for calculating the minimal electricity, showed here by Joules, necessary for the transference of electrons. There is already a Table, in which you find the result of all of the electric transfer necessary in most of the materials. In this article, we tried to generaliz…
▽ More
The purpose of this article is to show a different way to calculate the electron transfer between atoms. It can be used as a base for calculating the minimal electricity, showed here by Joules, necessary for the transference of electrons. There is already a Table, in which you find the result of all of the electric transfer necessary in most of the materials. In this article, we tried to generalize the electricity necessary, but if you want the result in a specific field or material, you can search the references and collaborates workers.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
Results of the first user program on the Homogenous Thermal Neutron Source HOTNES (ENEA / INFN)
Authors:
A. Sperduti,
M. Angelone,
R. Bedogni,
G. Claps,
E. Diociaiuti,
C. Domingo,
R. Donghia,
S. Giovannella,
J. M. Gomez-Ros,
L. Irazola-Rosales,
S. Loreti,
V. Monti,
S. Miscetti,
F. Murtas,
G. Pagano,
M. Pillon,
R. Pilotti,
A. Pola,
M. Romero-Expósito,
F. Sánchez-Doblado,
O. Sans-Planell,
A. Scherillo,
E. Soldani,
M. Treccani,
A. Pietropaolo
Abstract:
The HOmogeneous Thermal NEutron Source (HOTNES) is a new type of thermal neutron irradiation assembly developed by the ENEA-INFN collaboration. The facility is fully characterized in terms of neutron field and dosimetric quantities, by either computational and experimental methods. This paper reports the results of the first "HOTNES users program", carried out in 2016, and covering a variety of th…
▽ More
The HOmogeneous Thermal NEutron Source (HOTNES) is a new type of thermal neutron irradiation assembly developed by the ENEA-INFN collaboration. The facility is fully characterized in terms of neutron field and dosimetric quantities, by either computational and experimental methods. This paper reports the results of the first "HOTNES users program", carried out in 2016, and covering a variety of thermal neutron active detectors such as scintillators, solid-state, single crystal diamond and gaseous detectors.
△ Less
Submitted 22 February, 2018;
originally announced February 2018.
-
Upgrade of compact neutron spectrometer for high flux environments
Authors:
M. Osipenko,
A. Bellucci,
V. Ceriale,
D. Corsini,
G. Gariano,
F. Gatti,
M. Girolami,
S. Minutoli,
F. Panza,
M. Pillon,
M. Ripani,
D. M. Trucchi
Abstract:
In this paper a new version of Li6-based neutron spectrometer for high flux environments is described. The new spectrometer was built with commercial single crystal Chemical Vapour Deposition diamonds of electronic grade. These crystals feature better charge collection as well as higher radiation hardness. Ohmic metal contacts were deposited on the diamonds suppressing build-up of space charge obs…
▽ More
In this paper a new version of Li6-based neutron spectrometer for high flux environments is described. The new spectrometer was built with commercial single crystal Chemical Vapour Deposition diamonds of electronic grade. These crystals feature better charge collection as well as higher radiation hardness. Ohmic metal contacts were deposited on the diamonds suppressing build-up of space charge observed in the previous prototypes. New passive preamplification of signal at detector side was implemented to improve the resolution. This preamplification is based on RF transformer not sensitive to high neutron flux. Compact mechanical design allowed to reduce detector size to a tube of 1 cm diameter and 13 cm long. The spectrometer was tested in thermal column of TRIGA reactor and at DD neutron generator. The test results indicate an energy resolution of 72 keV (RMS) and coincidence timing resolution of 68 ps (RMS). The measured data are in agreement with Geant4 simulations except for larger energy loss tail presumably related to imperfections of metal contacts and glue expansion.
△ Less
Submitted 18 July, 2017;
originally announced July 2017.
-
Irradiation study of UV Silicon Photomultipliers for the Mu2e Calorimeter
Authors:
S. Baccaro,
A. Cemmi,
M. Cordelli,
E. Diociaiuti,
R. Donghia,
A. Ferrari,
S. Giovannella,
S. Miscetti,
S. Müller,
M. Pillon,
I. Sarra
Abstract:
The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position resolutions. It should also be fast enough to handle the high rate background and it must operate and survive in the high radiation environment. Simulatio…
▽ More
The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position resolutions. It should also be fast enough to handle the high rate background and it must operate and survive in the high radiation environment. Simulation studies estimated that, in the highest irradiated regions, each photo-sensor will absorb a dose of 20 krad and will be exposed to a neutron fluency of 5.5x10^11 n_(1MeV)/cm^2 in three years of running, with a safety factor of 3 included. At the end of 2015, we have concluded an irradiation campaign at the Frascati Neutron Generator (FNG, Frascati, Italy) measuring the response of two different 16 array models from Hamamatsu, which differ for the protection windows and a SiPM from FBK. In 2016, we have carried out two additional irradiation campaigns with neutrons and photons at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR, Dresden, Germany) and at the Calliope gamma irradiation facility at ENEA-Casaccia, respectively. A negligible increment of the leakage current and no gain change have been observed with the dose irradiation. On the other hand, at the end of the neutron irradiation, the gain does not show large changes whilst the leakage current increases by around a factor of 2000. In these conditions, the too high leakage current makes problematic to bias the SiPMs, thus requiring to cool them down to a running temperature of ~0 °C.
△ Less
Submitted 23 January, 2017;
originally announced January 2017.
-
Radiation hardness test of un-doped CsI crystals and Silicon Photomultipliers for the Mu2e calorimeter
Authors:
Stefania Baccaro,
Alessia Cemmi,
Marco Cordelli,
Eleonora Diociaiuti,
Raffaella Donghia,
Simona Giovannella,
Stefano Loreti,
Stefano Miscetti,
Mario Pillon,
Ivano Sarra
Abstract:
The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It should also be fast enough to handle the high rate background and it must operate and survive in a high radiation environment. Simulation studies estimated that…
▽ More
The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It should also be fast enough to handle the high rate background and it must operate and survive in a high radiation environment. Simulation studies estimated that, in the hottest regions, each crystal will absorb a dose of 300 Gy and will be exposed to a neutron fluency of 6 x 10^{11} n/cm^2 in 3 years of running.
Test of un-doped CsI crystals irradiated up to 900 Gy and to a neutron fluency up to 9 x 10^{11} n/cm^2 have been performed at CALLIOPE and FNG ENEA facilities in Italy. We present our study on the variation of light yield (LY) and longitudinal response uniformity (LRU) of these crystals after irradiation. The ionization dose does not modify LRU while a 20% reduction in LY is observed at 900 Gy. Similarly, the neutron flux causes an acceptable LY deterioration (<15%). A neutron irradiation test on different types of SIPMs (two different array models from Hamamatsu and one from FBK) have also been carried out by measuring the variation of the leakage current and the charge response to an ultraviolet led. We concluded that, in the experiment, we will need to cool down the SIPMs to 0 C reduce the leakage current to an acceptable level.
△ Less
Submitted 23 June, 2016;
originally announced June 2016.
-
Response of diamond detector sandwich to 14 MeV neutrons
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
G. Verona-Rinati,
R. Cardarelli
Abstract:
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detector…
▽ More
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detectors suffer significant radiation damage already at neutron fluences of the order of $10^{14}$ n/cm$^2$. It is expected that a 50 $μ$m thick diamond will withstand a fluence of $>10^{16}$ n/cm$^2$. We tested two 50 $μ$m thick single crystal CVD diamonds, stacked to form a "sandwich" detector for coincidence measurements. The detector measured the conversion of 14 MeV neutrons, impinging on one diamond, into $α$ particles which were detected in the second diamond in coincidence with nuclear recoil. For $^{12}C(n,α)^{9}Be$ reaction the total energy deposited in the detector gives access to the initial neutron energy value. The measured 14 MeV neutron detection sensitivity through this reaction by a detector of effective area 3$\times$3 mm$^2$ was $5\times 10^{-7}$ counts cm$^2$/n. This value is in good agreement with Geant4 simulations. The intrinsic energy resolution of the detector was found to be 240 keV FWHM which adds only 10 % to ITER's 14 MeV neutron energy spread.
△ Less
Submitted 2 November, 2015; v1 submitted 19 October, 2015;
originally announced October 2015.
-
Neutron spectrometer for fast nuclear reactors
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
M. Angelone,
G. Verona-Rinati,
R. Cardarelli,
G. Mila,
S. Argiro
Abstract:
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamo…
▽ More
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamond detectors, which measure the two reaction products in coincidence. The spectrometer was calibrated at two neutron energies in well known thermal and 3 MeV neutron fluxes. The measured neutron detection efficiency varies from 4.2$\times 10^{-4}$ to 3.5$\times 10^{-8}$ for thermal and 3 MeV neutrons, respectively. These values are in agreement with Geant4 simulations and close to simple estimates based on the knowledge of the $^6$Li(n,$α$)$t$ cross section. The energy resolution of the spectrometer was found to be better than 100 keV when using 5 m cables between the detector and the preamplifiers.
△ Less
Submitted 25 May, 2015;
originally announced May 2015.
-
Proton recoil telescope based on diamond detectors for measurement of fusion neutrons
Authors:
B. Caiffi,
M. Osipenko,
M. Ripani,
M. Pillon,
M. Taiuti
Abstract:
Diamonds are very promising candidates for the neutron diagnostics in harsh environments such as fusion reactor. In the first place this is because of their radiation hardness, exceeding that of Silicon by an order of magnitude. Also, in comparison to the standard on-line neutron diagnostics (fission chambers, silicon based detectors, scintillators), diamonds are less sensitive to $γ$ rays, which…
▽ More
Diamonds are very promising candidates for the neutron diagnostics in harsh environments such as fusion reactor. In the first place this is because of their radiation hardness, exceeding that of Silicon by an order of magnitude. Also, in comparison to the standard on-line neutron diagnostics (fission chambers, silicon based detectors, scintillators), diamonds are less sensitive to $γ$ rays, which represent a huge background in fusion devices. Finally, their low leakage current at high temperature suppresses the detector intrinsic noise. In this talk a CVD diamond based detector has been proposed for the measurement of the 14 MeV neutrons from D-T fusion reaction. The detector was arranged in a proton recoil telescope configuration, featuring a plastic converter in front of the sensitive volume in order to induce the (n,p) reaction. The segmentation of the sensitive volume, achieved by using two crystals, allowed to perform measurements in coincidence, which suppressed the neutron elastic scattering background. A preliminary prototype was assembled and tested at FNG (Frascati Neutron Generator, ENEA), showing promising results regarding efficiency and energy resolution.
△ Less
Submitted 23 May, 2015;
originally announced May 2015.
-
Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor
Authors:
M. Osipenko,
F. Pompili,
M. Ripani,
M. Pillon,
G. Ricco,
B. Caiffi,
R. Cardarelli,
G. Verona-Rinati,
S. Argiro
Abstract:
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energ…
▽ More
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of $10^8$ n/cm$^2$s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of $10^6$ n/cm$^2$s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10$^9$ n/cm$^2$s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4.
△ Less
Submitted 23 May, 2015;
originally announced May 2015.
-
Further investigations on the Neutron Flux Generation in a Plasma Discharge Electrolytic Cell
Authors:
R. Faccini,
A. Pilloni,
A. D. Polosa,
M. Angelone,
E. Castagna,
S. Lecci,
S. Loreti,
A. Pietropaolo,
M. Pillon,
M. Sansovini,
F. Sarto,
V. Violante,
R. Bedogni,
A. Esposito
Abstract:
Our recent paper on the "Search for Neutron Flux Generation in a Plasma Discharge Electrolytic Cell" [1] has as main goal the validation of the experiment in Ref.[2]. As a follow-up, Ref.[3] moves a set of objections on our procedure and presents argumentations on why the experiments should not yield the same results. We collect here additional material and calculations that contribute to understa…
▽ More
Our recent paper on the "Search for Neutron Flux Generation in a Plasma Discharge Electrolytic Cell" [1] has as main goal the validation of the experiment in Ref.[2]. As a follow-up, Ref.[3] moves a set of objections on our procedure and presents argumentations on why the experiments should not yield the same results. We collect here additional material and calculations that contribute to understanding the observed discrepancies. Furthermore we prove that the absence of signals from Indium activation detectors reported also for the experiment of Ref.[2] is a clear indication that neutron production does not occur.
[1] R.Faccini et al arXiv:1310.4749
[2] D.Cirillo et al, Key Engineering Materials 495, 104 (2012).
[3] A.Widom et al. arXiv:1311.2447
△ Less
Submitted 30 January, 2014;
originally announced January 2014.
-
Search for Neutron Flux Generation in a Plasma Discharge Electrolytic Cell
Authors:
R. Faccini,
A. Pilloni,
A. D. Polosa,
M. Angelone,
E. Castagna,
S. Lecci,
A. Pietropaolo,
M. Pillon,
M. Sansovini,
F. Sarto,
V. Violante,
R. Bedogni,
A. Esposito
Abstract:
Following some recent unexpected hints of neutron production in setups like high-voltage atmospheric discharges and plasma discharges in electrolytic cells, we present a measurement of the neutron flux in a configuration similar to the latter. We use two different types of neutron detectors, poly-allyl-diglicol-carbonate (PADC, aka CR-39) tracers and Indium disks. At 95% C.L. we provide an upper l…
▽ More
Following some recent unexpected hints of neutron production in setups like high-voltage atmospheric discharges and plasma discharges in electrolytic cells, we present a measurement of the neutron flux in a configuration similar to the latter. We use two different types of neutron detectors, poly-allyl-diglicol-carbonate (PADC, aka CR-39) tracers and Indium disks. At 95% C.L. we provide an upper limit of 1.5 neutrons cm^-2 s^-1 for the thermal neutron flux at ~5 cm from the center of the cell. Allowing for a higher energy neutron component the largest allowed flux is 64 neutrons cm^-2 s^-1. This upper limit is two orders of magnitude smaller than what previously claimed in an electrolytic cell plasma discharge experiment. Furthermore the behavior of the CR-39 is discussed to point our possible sources of spurious signals.
△ Less
Submitted 17 October, 2013;
originally announced October 2013.
-
IRIDE White Book, An Interdisciplinary Research Infrastructure based on Dual Electron linacs&lasers
Authors:
D. Alesini,
M. Alessandroni,
M. P. Anania,
S. Andreas,
M. Angelone,
A. Arcovito,
F. Arnesano,
M. Artioli,
L. Avaldi,
D. Babusci,
A. Bacci,
A. Balerna,
S. Bartalucci,
R. Bedogni,
M. Bellaveglia,
F. Bencivenga,
M. Benfatto,
S. Biedron,
V. Bocci,
M. Bolognesi,
P. Bolognesi,
R. Boni,
R. Bonifacio,
M. Boscolo,
F. Boscherini
, et al. (189 additional authors not shown)
Abstract:
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high ener…
▽ More
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of science and technology. IRIDE will contribute to open new avenues of discoveries and to address most important riddles: What does matter consist of? What is the structure of proteins that have a fundamental role in life processes? What can we learn from protein structure to improve the treatment of diseases and to design more efficient drugs? But also how does an electronic chip behave under the effect of radiations? How can the heat flow in a large heat exchanger be optimized? The scientific potential of IRIDE is far reaching and justifies the construction of such a large facility in Italy in synergy with the national research institutes and companies and in the framework of the European and international research. It will impact also on R&D work for ILC, FEL, and will be complementarity to other large scale accelerator projects. IRIDE is also intended to be realized in subsequent stages of development depending on the assigned priorities.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.
-
Properties of para-terphenyl as detector for alpha, beta and gamma radiation
Authors:
M. Angelone,
G. Battistoni,
F. Bellini,
V. Bocci,
F. Collamati,
E. De Lucia,
R. Faccini,
F. Ferroni,
S. Fiore,
M. Marafini,
D. Materazzo,
I. Mattei,
S. Morganti,
V. Patera,
L. Piersanti,
M. Pillon,
L. Recchia,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
C. Voena
Abstract:
Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a blend of properties of the two categories that can be optimal for energy and position measurements of low energy charged particles. On 0.1% diphenylbutadiene doped…
▽ More
Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a blend of properties of the two categories that can be optimal for energy and position measurements of low energy charged particles. On 0.1% diphenylbutadiene doped para-terphenyl samples we measure a light yield 3.5+-0.2 times larger than a typical organic scintillator (EJ-200), and a rejection power for 660 keV photons, with respect to electrons of the same energy, ranging between 3-11%, depending on the signal threshold. We also measure a light attenuation length = 4.73+-0.06 mm and we demonstrate that, with the measurements performed in this paper, a simulation based on FLUKA can properly reproduce the measured spectra.
△ Less
Submitted 2 May, 2013;
originally announced May 2013.
-
Silicon Photo-Multiplier radiation hardness tests with a beam controlled neutron source
Authors:
M. Angelone,
M. Pillon,
R. Faccini,
D. Pinci,
W. Baldini,
R. Calabrese,
G. Cibinetto,
A. Cotta Ramusino,
R. Malaguti,
M. Pozzati
Abstract:
We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to 7x10^10 1-MeV-equivalent neutrons per cm^2. Detector performances have been recorded during the neu…
▽ More
We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to 7x10^10 1-MeV-equivalent neutrons per cm^2. Detector performances have been recorded during the neutron irradiation and a gradual deterioration of their properties was found to happen already after an integrated fluence of the order of 10^8 1-MeV-equivalent neutrons per cm^2.
△ Less
Submitted 8 June, 2010; v1 submitted 18 February, 2010;
originally announced February 2010.