-
Can patient-specific acquisition protocol improve performance on defect detection task in myocardial perfusion SPECT?
Authors:
Nu Ri Choi,
Md Ashequr Rahman,
Zitong Yu,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Myocardial perfusion imaging using single-photon emission computed tomography (SPECT), or myocardial perfusion SPECT (MPS) is a widely used clinical imaging modality for the diagnosis of coronary artery disease. Current clinical protocols for acquiring and reconstructing MPS images are similar for most patients. However, for patients with outlier anatomical characteristics, such as large breasts,…
▽ More
Myocardial perfusion imaging using single-photon emission computed tomography (SPECT), or myocardial perfusion SPECT (MPS) is a widely used clinical imaging modality for the diagnosis of coronary artery disease. Current clinical protocols for acquiring and reconstructing MPS images are similar for most patients. However, for patients with outlier anatomical characteristics, such as large breasts, images acquired using conventional protocols are often sub-optimal in quality, leading to degraded diagnostic accuracy. Solutions to improve image quality for these patients outside of increased dose or total acquisition time remain challenging. Thus, there is an important need for new methodologies to improve image quality for such patients. One approach to improving this performance is adapting the image acquisition protocol specific to each patient. For this study, we first designed and implemented a personalized patient-specific protocol-optimization strategy, which we term precision SPECT (PRESPECT). This strategy integrates ideal observer theory with the constraints of tomographic reconstruction to optimize the acquisition time for each projection view, such that MPS defect detection performance is maximized. We performed a clinically realistic simulation study on patients with outlier anatomies on the task of detecting perfusion defects on various realizations of low-dose scans by an anthropomorphic channelized Hotelling observer. Our results show that using PRESPECT led to improved performance on the defect detection task for the considered patients. These results provide evidence that personalization of MPS acquisition protocol has the potential to improve defect detection performance, motivating further research to design optimal patient-specific acquisition and reconstruction protocols for MPS, as well as developing similar approaches for other medical imaging modalities.
△ Less
Submitted 26 March, 2024;
originally announced March 2024.
-
Levitodynamic spectroscopy for single nanoparticle characterisation
Authors:
Jonathan M. H. Gosling,
Markus Rademacher,
Jence T. Mulder,
Arjan J. Houtepen,
Marko Toroš,
A. T. M. Anishur Rahman,
Antonio Pontin,
P. F. Barker
Abstract:
Fast detection and characterization of single nanoparticles such as viruses, airborne aerosols and colloidal particles are considered to be particularly important for medical applications, material science and atmospheric physics. In particular, non-intrusive optical characterization, which can be carried out in isolation from other particles, and without the deleterious effects of a substrate or…
▽ More
Fast detection and characterization of single nanoparticles such as viruses, airborne aerosols and colloidal particles are considered to be particularly important for medical applications, material science and atmospheric physics. In particular, non-intrusive optical characterization, which can be carried out in isolation from other particles, and without the deleterious effects of a substrate or solvent, is seen to be particularly important. Optical characterization via the scattering of light does not require complicated sample preparation and can in principle be carried out in-situ. We describe the characterization of single nanoparticle shape based on the measurement of their rotational and oscillatory motion when optically levitated within vacuum. Using colloidally grown yttrium lithium fluoride nanocrystals of different sizes, trapped in a single-beam optical tweezer, we demonstrate the utility of this method which is in good agreement with simulations of the dynamics. Size differences as small as a few nanometers could be resolved using this technique offering a new optical spectroscopic tool for non-contact characterization of single nanoparticles in the absence of a substrate.
△ Less
Submitted 21 January, 2024;
originally announced January 2024.
-
Reconfigurable Image Processing Metasurfaces with Phase-Change Materials
Authors:
Michele Cotrufo,
Shaban B. Sulejman,
Lukas Wesemann,
Md. Ataur Rahman,
Madhu Bhaskaran,
Ann Roberts,
Andrea Alù
Abstract:
Optical metasurfaces have been enabling reduced footprint and power consumption, as well as faster speeds, in the context of analog computing and image processing. While various image processing and optical computing functionalities have been recently demonstrated using metasurfaces, most of the considered devices are static and lack reconfigurability. Yet, the ability to dynamically reconfigure p…
▽ More
Optical metasurfaces have been enabling reduced footprint and power consumption, as well as faster speeds, in the context of analog computing and image processing. While various image processing and optical computing functionalities have been recently demonstrated using metasurfaces, most of the considered devices are static and lack reconfigurability. Yet, the ability to dynamically reconfigure processing operations is key for metasurfaces to be able to compete with practical computing systems. Here, we demonstrate a passive edge-detection metasurface operating in the near-infrared regime whose image processing response can be drastically modified by temperature variations smaller than 10° C around a CMOS-compatible temperature of 65° C. Such reconfigurability is achieved by leveraging the insulator-to-metal phase transition of a thin buried layer of vanadium dioxide which, in turn, strongly alters the nonlocal response of the metasurface. Importantly, this reconfigurability is accompanied by performance metrics - such as high numerical aperture, high efficiency, isotropy, and polarization-independence - close to optimal, and it is combined with a simple geometry compatible with large-scale manufacturing. Our work paves the way to a new generation of ultra-compact, tunable, passive devices for all-optical computation, with potential applications in augmented reality, remote sensing and bio-medical imaging.
△ Less
Submitted 21 November, 2023;
originally announced November 2023.
-
A Computational Approach to Evaluate the Effect of Shelter Construction Material and Fuel Load on the Fire Spread Behavior in Rohingya Refugee Camp
Authors:
Md. Fahad Hossain Mishu,
Rafia Rizwana Rahim,
Md. Ashiqur Rahman
Abstract:
Numerous fires break out, especially from January to March every year, destroying thousands of shelters in the Rohingya Refugee Camps. In this study, a computational approach has been taken to analyze the fire dynamic behavior of informal settlements (ISs) in Rohingya Refugee Camps. The design parameters for the mathematical model are determined based on a comprehensive survey carried out in Rohin…
▽ More
Numerous fires break out, especially from January to March every year, destroying thousands of shelters in the Rohingya Refugee Camps. In this study, a computational approach has been taken to analyze the fire dynamic behavior of informal settlements (ISs) in Rohingya Refugee Camps. The design parameters for the mathematical model are determined based on a comprehensive survey carried out in Rohingya Refugee Camps in Cox's Bazar, Bangladesh. This survey is conducted on three camps having distinctive fuel features, i.e., Kutupalong Registered Camp (KRC), Camp 5, and Camp 4 Extension (Ex), in order to accumulate data on the type, density, arrangement of fuel, etc. Using the dataset of almost 500 shelters having 42 fuel characteristics features, simplified small scale representation of each camp under fire had been modelled in Fire Dynamic Simulator (FDS). It is found that Camp 5 is more vulnerable to fire hazard than Camp 4 Ex and KRC because of the dense fuel arrangement, bamboo structure and negligible separation distance between ISs. KRC's brick exterior acts as a fire barrier, and thereby despite having the largest internal fuel load of all three camps, prevents further spreading of fire from the ignited enclosure. It is also found that type of building material and separation distance are crucial for fire spread and increasing fuel load density causes the ceiling temperature to rise higher and the flashover point to approach faster. The findings of our study can be helpful for informed decision making of fire safety measures in the Rohingya Refugee Camps.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
DEMIST: A deep-learning-based task-specific denoising approach for myocardial perfusion SPECT
Authors:
Md Ashequr Rahman,
Zitong Yu,
Richard Laforest,
Craig K. Abbey,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
There is an important need for methods to process myocardial perfusion imaging (MPI) SPECT images acquired at lower radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose…
▽ More
There is an important need for methods to process myocardial perfusion imaging (MPI) SPECT images acquired at lower radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose a Detection task-specific deep-learning-based approach for denoising MPI SPECT images (DEMIST). The approach, while performing denoising, is designed to preserve features that influence observer performance on detection tasks. We objectively evaluated DEMIST on the task of detecting perfusion defects using a retrospective study with anonymized clinical data in patients who underwent MPI studies across two scanners (N = 338). The evaluation was performed at low-dose levels of 6.25%, 12.5% and 25% and using an anthropomorphic channelized Hotelling observer. Performance was quantified using area under the receiver operating characteristics curve (AUC). Images denoised with DEMIST yielded significantly higher AUC compared to corresponding low-dose images and images denoised with a commonly used task-agnostic DL-based denoising method. Similar results were observed with stratified analysis based on patient sex and defect type. Additionally, DEMIST improved visual fidelity of the low-dose images as quantified using root mean squared error and structural similarity index metric. A mathematical analysis revealed that DEMIST preserved features that assist in detection tasks while improving the noise properties, resulting in improved observer performance. The results provide strong evidence for further clinical evaluation of DEMIST to denoise low-count images in MPI SPECT.
△ Less
Submitted 25 October, 2023; v1 submitted 7 June, 2023;
originally announced June 2023.
-
A list-mode multi-energy window low-count SPECT reconstruction method for isotopes with multiple emission peaks
Authors:
Md Ashequr Rahman,
Zekun Li,
Zitong Yu,
Richard Laforest,
Daniel L. J. Thorek,
Abhinav K. Jha
Abstract:
SPECT provides a mechanism to perform absorbed-dose quantification tasks for $α$-particle radiopharmaceutical therapies ($α$-RPTs). However, quantitative SPECT for $α$-RPT is challenging due to the low number of detected counts, the complex emission spectrum, and other image-degrading artifacts. Towards addressing these challenges, we propose a low-count quantitative SPECT reconstruction method fo…
▽ More
SPECT provides a mechanism to perform absorbed-dose quantification tasks for $α$-particle radiopharmaceutical therapies ($α$-RPTs). However, quantitative SPECT for $α$-RPT is challenging due to the low number of detected counts, the complex emission spectrum, and other image-degrading artifacts. Towards addressing these challenges, we propose a low-count quantitative SPECT reconstruction method for isotopes with multiple emission peaks.
Given the low-count setting, it is important that the reconstruction method extract the maximal possible information from each detected photon. Processing data over multiple energy windows and in list-mode (LM) format provide mechanisms to achieve that objective. Towards this goal, we propose a list-mode multi-energy window (LM-MEW) OSEM-based SPECT reconstruction method that uses data from multiple energy windows in LM format, and includes the energy attribute of each detected photon. For computational efficiency, we developed a multi-GPU-based implementation of this method. The method was evaluated using 2-D SPECT simulation studies in a single-scatter setting conducted in the context of imaging [$^{223}$Ra]RaCl${_2}$.
The proposed method yielded improved performance on the task of estimating activity uptake within known regions of interest in comparison to approaches that use a single energy window or use binned data. The improved performance was observed in terms of both accuracy and precision and for different sizes of the region of interest.
Results of our studies show that the use of multiple energy windows and processing data in LM format with the proposed LM-MEW method led to improved quantification performance in low-count SPECT of isotopes with multiple emission peaks. These results motivate further development and validation of the LM-MEW method for such imaging applications, including for $α$-RPT SPECT.
△ Less
Submitted 26 May, 2023;
originally announced May 2023.
-
Need for Objective Task-based Evaluation of Deep Learning-Based Denoising Methods: A Study in the Context of Myocardial Perfusion SPECT
Authors:
Zitong Yu,
Md Ashequr Rahman,
Richard Laforest,
Thomas H. Schindler,
Robert J. Gropler,
Richard L. Wahl,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Artificial intelligence-based methods have generated substantial interest in nuclear medicine. An area of significant interest has been using deep-learning (DL)-based approaches for denoising images acquired with lower doses, shorter acquisition times, or both. Objective evaluation of these approaches is essential for clinical application. DL-based approaches for denoising nuclear-medicine images…
▽ More
Artificial intelligence-based methods have generated substantial interest in nuclear medicine. An area of significant interest has been using deep-learning (DL)-based approaches for denoising images acquired with lower doses, shorter acquisition times, or both. Objective evaluation of these approaches is essential for clinical application. DL-based approaches for denoising nuclear-medicine images have typically been evaluated using fidelity-based figures of merit (FoMs) such as RMSE and SSIM. However, these images are acquired for clinical tasks and thus should be evaluated based on their performance in these tasks. Our objectives were to (1) investigate whether evaluation with these FoMs is consistent with objective clinical-task-based evaluation; (2) provide a theoretical analysis for determining the impact of denoising on signal-detection tasks; (3) demonstrate the utility of virtual clinical trials (VCTs) to evaluate DL-based methods. A VCT to evaluate a DL-based method for denoising myocardial perfusion SPECT (MPS) images was conducted. The impact of DL-based denoising was evaluated using fidelity-based FoMs and AUC, which quantified performance on detecting perfusion defects in MPS images as obtained using a model observer with anthropomorphic channels. Based on fidelity-based FoMs, denoising using the considered DL-based method led to significantly superior performance. However, based on ROC analysis, denoising did not improve, and in fact, often degraded detection-task performance. The results motivate the need for objective task-based evaluation of DL-based denoising approaches. Further, this study shows how VCTs provide a mechanism to conduct such evaluations using VCTs. Finally, our theoretical treatment reveals insights into the reasons for the limited performance of the denoising approach.
△ Less
Submitted 1 April, 2023; v1 submitted 3 March, 2023;
originally announced March 2023.
-
A task-specific deep-learning-based denoising approach for myocardial perfusion SPECT
Authors:
Md Ashequr Rahman,
Zitong Yu,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Deep-learning (DL)-based methods have shown significant promise in denoising myocardial perfusion SPECT images acquired at low dose. For clinical application of these methods, evaluation on clinical tasks is crucial. Typically, these methods are designed to minimize some fidelity-based criterion between the predicted denoised image and some reference normal-dose image. However, while promising, st…
▽ More
Deep-learning (DL)-based methods have shown significant promise in denoising myocardial perfusion SPECT images acquired at low dose. For clinical application of these methods, evaluation on clinical tasks is crucial. Typically, these methods are designed to minimize some fidelity-based criterion between the predicted denoised image and some reference normal-dose image. However, while promising, studies have shown that these methods may have limited impact on the performance of clinical tasks in SPECT. To address this issue, we use concepts from the literature on model observers and our understanding of the human visual system to propose a DL-based denoising approach designed to preserve observer-related information for detection tasks. The proposed method was objectively evaluated on the task of detecting perfusion defect in myocardial perfusion SPECT images using a retrospective study with anonymized clinical data. Our results demonstrate that the proposed method yields improved performance on this detection task compared to using low-dose images. The results show that by preserving task-specific information, DL may provide a mechanism to improve observer performance in low-dose myocardial perfusion SPECT.
△ Less
Submitted 28 February, 2023;
originally announced March 2023.
-
Development and task-based evaluation of a scatter-window projection and deep learning-based transmission-less attenuation compensation method for myocardial perfusion SPECT
Authors:
Zitong Yu,
Md Ashequr Rahman,
Craig K. Abbey,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Attenuation compensation (AC) is beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, traditional AC methods require the availability of a transmission scan, most often a CT scan. This approach has the disadvantages of increased radiation dose, increased scanner cost, and the possibility of inaccurate diagnosi…
▽ More
Attenuation compensation (AC) is beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, traditional AC methods require the availability of a transmission scan, most often a CT scan. This approach has the disadvantages of increased radiation dose, increased scanner cost, and the possibility of inaccurate diagnosis in cases of misregistration between the SPECT and CT images. Further, many SPECT systems do not include a CT component. To address these issues, we developed a Scatter-window projection and deep Learning-based AC (SLAC) method to perform AC without a separate transmission scan. To investigate the clinical efficacy of this method, we then objectively evaluated the performance of this method on the clinical task of detecting perfusion defects on MPI in a retrospective study with anonymized clinical SPECT/CT stress MPI images. The proposed method was compared with CT-based AC (CTAC) and no-AC (NAC) methods. Our results showed that the SLAC method yielded an almost overlapping receiver operating characteristic (ROC) plot and a similar area under the ROC (AUC) to the CTAC method on this task. These results demonstrate the capability of the SLAC method for transmission-less AC in SPECT and motivate further clinical evaluation.
△ Less
Submitted 18 March, 2023; v1 submitted 28 February, 2023;
originally announced March 2023.
-
Neural Operator: Is data all you need to model the world? An insight into the impact of Physics Informed Machine Learning
Authors:
Hrishikesh Viswanath,
Md Ashiqur Rahman,
Abhijeet Vyas,
Andrey Shor,
Beatriz Medeiros,
Stephanie Hernandez,
Suhas Eswarappa Prameela,
Aniket Bera
Abstract:
Numerical approximations of partial differential equations (PDEs) are routinely employed to formulate the solution of physics, engineering and mathematical problems involving functions of several variables, such as the propagation of heat or sound, fluid flow, elasticity, electrostatics, electrodynamics, and more. While this has led to solving many complex phenomena, there are some limitations. Co…
▽ More
Numerical approximations of partial differential equations (PDEs) are routinely employed to formulate the solution of physics, engineering and mathematical problems involving functions of several variables, such as the propagation of heat or sound, fluid flow, elasticity, electrostatics, electrodynamics, and more. While this has led to solving many complex phenomena, there are some limitations. Conventional approaches such as Finite Element Methods (FEMs) and Finite Differential Methods (FDMs) require considerable time and are computationally expensive. In contrast, data driven machine learning-based methods such as neural networks provide a faster, fairly accurate alternative, and have certain advantages such as discretization invariance and resolution invariance. This article aims to provide a comprehensive insight into how data-driven approaches can complement conventional techniques to solve engineering and physics problems, while also noting some of the major pitfalls of machine learning-based approaches. Furthermore, we highlight, a novel and fast machine learning-based approach (~1000x) to learning the solution operator of a PDE operator learning. We will note how these new computational approaches can bring immense advantages in tackling many problems in fundamental and applied physics.
△ Less
Submitted 18 September, 2023; v1 submitted 30 January, 2023;
originally announced January 2023.
-
Fiber-coupled Diamond Magnetometry with an Unshielded 30 pT/$\sqrt{\textrm{Hz}}$ Sensitivity
Authors:
S. M. Graham,
A. T. M. A. Rahman,
L. Munn,
R. L. Patel,
A. J. Newman,
C. J. Stephen,
G. Colston,
A. Nikitin,
A. M. Edmonds,
D. J. Twitchen,
M. L. Markham,
G. W. Morley
Abstract:
Ensembles of nitrogen vacancy centres (NVCs) in diamond can be employed for sensitive magnetometry. In this work we present a fiber-coupled NVC magnetometer with an unshielded sensitivity of (30 $\pm$ 10) pT/$\sqrt{\textrm{Hz}}$ in a (10 - 500)-Hz frequency range. This sensitivity is enabled by a relatively high green-to-red photon conversion efficiency, the use of a [100] bias field alignment, mi…
▽ More
Ensembles of nitrogen vacancy centres (NVCs) in diamond can be employed for sensitive magnetometry. In this work we present a fiber-coupled NVC magnetometer with an unshielded sensitivity of (30 $\pm$ 10) pT/$\sqrt{\textrm{Hz}}$ in a (10 - 500)-Hz frequency range. This sensitivity is enabled by a relatively high green-to-red photon conversion efficiency, the use of a [100] bias field alignment, microwave and lock-in amplifier (LIA) parameter optimisation, as well as a balanced hyperfine excitation scheme. Furthermore, a silicon carbide (SiC) heat spreader is used for microwave delivery, alongside low-strain $^{12}\textrm{C}$ diamonds, one of which is placed in a second magnetically insensitive fluorescence collecting sensor head for common-mode noise cancellation. The magnetometer is capable of detecting signals from sources such as a vacuum pump up to 2 m away, with some orientation dependence but no complete dead zones, demonstrating its potential for use in remote sensing applications.
△ Less
Submitted 23 March, 2023; v1 submitted 16 November, 2022;
originally announced November 2022.
-
Measurement of the motional heating of a levitated nanoparticle by thermal light
Authors:
A. T. M. Anishur Rahman,
P. F. Barker
Abstract:
We report on measurements of photon induced heating of silica nanospheres levitated in vacuum by a thermal light source formed by a superluminescent diode. Heating of the nanospheres motion along the three trap axes was measured as a function of gas pressure and for two particle sizes. Heating rates were also compared with the much lower reheating of the same sphere when levitated by a laser. We f…
▽ More
We report on measurements of photon induced heating of silica nanospheres levitated in vacuum by a thermal light source formed by a superluminescent diode. Heating of the nanospheres motion along the three trap axes was measured as a function of gas pressure and for two particle sizes. Heating rates were also compared with the much lower reheating of the same sphere when levitated by a laser. We find the measured trap heating rates are dominated by the much larger heating rates expected from the recoil of thermal photons.
△ Less
Submitted 21 April, 2022;
originally announced April 2022.
-
Facile synthesis of Cu2O nanorods in the presence of NaCl by SILAR method and its characterizations
Authors:
Md. Alauddin Hossain,
Syed Farid Uddin Farhad,
Nazmul Islam Tanvir,
Jang Hyo Chang,
Mohammad Atiqur Rahman,
Tooru Tanaka,
Qixin Guo,
Jamal Uddin,
Md Abdul Majed Patwary
Abstract:
Cu2O nanorods have been deposited on soda-lime glass (SLG) substrates by the modified SILAR technique by varying the concentration of NaCl electrolyte into the precursor complex solution. The structural, electrical, and optical properties of synthesized Cu2O nanorod films have been studied by a variety of characterization tools. Structural analyses by XRD confirmed the polycrystalline Cu2O phase w…
▽ More
Cu2O nanorods have been deposited on soda-lime glass (SLG) substrates by the modified SILAR technique by varying the concentration of NaCl electrolyte into the precursor complex solution. The structural, electrical, and optical properties of synthesized Cu2O nanorod films have been studied by a variety of characterization tools. Structural analyses by XRD confirmed the polycrystalline Cu2O phase with (111) preferential growth. Raman scattering spectroscopic measurements conducted at room temperature also showed characteristic peaks of the pure Cu2O phase. The surface resistivity of the Cu2O nanorod films decreased from 15,142 to 685 Ohm.cm with the addition of NaCl from 0 to 4 mmol, and then exhibited an opposite trend with further addition of NaCl. The optical bandgap of the synthesized Cu2O nanorod films was observed as 1.88 - 2.36 eV, while the temperature-dependent activation energies of the Cu2O films were measured as about 0.14 - 0.21 eV. SEM morphologies demonstrated Cu2O nanorod as well as closely packed spherical grains with the alteration of NaCl concentration. The Cu2O phase of nanorods was found stable up to 230 0C corroborating the optical bandgap results of the same. The film fabricated in presence of 4 mmol of NaCl showed the lowest resistivity and activation energy as well comparatively uniform nanorod morphology. Our studies demonstrate that the nominal presence of NaCl electrolytes in the pre-cursor solutions has a significant impact on the physical properties of Cu2O nanorod films which could be beneficial in optoelectronic research.
△ Less
Submitted 22 March, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Ideal-observer computation with anthropomorphic phantoms using Markov Chain Monte Carlo
Authors:
Md Ashequr Rahman,
Zitong Yu,
Abhinav K. Jha
Abstract:
In medical imaging, it is widely recognized that image quality should be objectively evaluated based on performance in clinical tasks. To evaluate performance in signal-detection tasks, the ideal observer (IO) is optimal but also challenging to compute in clinically realistic settings. Markov Chain Monte Carlo (MCMC)-based strategies have demonstrated the ability to compute the IO using pre-comput…
▽ More
In medical imaging, it is widely recognized that image quality should be objectively evaluated based on performance in clinical tasks. To evaluate performance in signal-detection tasks, the ideal observer (IO) is optimal but also challenging to compute in clinically realistic settings. Markov Chain Monte Carlo (MCMC)-based strategies have demonstrated the ability to compute the IO using pre-computed projections of an anatomical database. To evaluate image quality in clinically realistic scenarios, the observer performance should be measured for realistic patient distribution. This implies that the anatomical database should also be derived from a realistic population. In this manuscript, we propose to advance the MCMC-based approach to achieve these goals. We then use the proposed approach to study the effect of anatomical database size on IO computation for the task of detecting perfusion defects in simulated myocardial perfusion SPECT images. Our preliminary results provide evidence that the size of the anatomical database affects the computation of IO.
△ Less
Submitted 7 March, 2022;
originally announced March 2022.
-
Investigating the limited performance of a deep-learning-based SPECT denoising approach: An observer-study-based characterization
Authors:
Zitong Yu,
Md Ashequr Rahman,
Abhinav K. Jha
Abstract:
Multiple objective assessment of image-quality-based studies have reported that several deep-learning-based denoising methods show limited performance on signal-detection tasks. Our goal was to investigate the reasons for this limited performance. To achieve this goal, we conducted a task-based characterization of a DL-based denoising approach for individual signal properties. We conducted this st…
▽ More
Multiple objective assessment of image-quality-based studies have reported that several deep-learning-based denoising methods show limited performance on signal-detection tasks. Our goal was to investigate the reasons for this limited performance. To achieve this goal, we conducted a task-based characterization of a DL-based denoising approach for individual signal properties. We conducted this study in the context of evaluating a DL-based approach for denoising SPECT images. The training data consisted of signals of different sizes and shapes within a clustered-lumpy background, imaged with a 2D parallel-hole-collimator SPECT system. The projections were generated at normal and 20% low count level, both of which were reconstructed using an OSEM algorithm. A CNN-based denoiser was trained to process the low-count images. The performance of this CNN was characterized for five different signal sizes and four different SBR by designing each evaluation as an SKE/BKS signal-detection task. Performance on this task was evaluated using an anthropomorphic CHO. As in previous studies, we observed that the DL-based denoising method did not improve performance on signal-detection tasks. Evaluation using the idea of observer-study-based characterization demonstrated that the DL-based denoising approach did not improve performance on the signal-detection task for any of the signal types. Overall, these results provide new insights on the performance of the DL-based denoising approach as a function of signal size and contrast. More generally, the observer study-based characterization provides a mechanism to evaluate the sensitivity of the method to specific object properties and may be explored as analogous to characterizations such as modulation transfer function for linear systems. Finally, this work underscores the need for objective task-based evaluation of DL-based denoising approaches.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
Intersonic Detachment Surface Waves in Elastomer Frictional Sliding
Authors:
Huifeng Du,
Emmanuel Virot,
Liying Wang,
Sam Kharchenko,
Md Arifur Rahman,
David A. Weitz,
Shmuel M. Rubinstein,
Nicholas X. Fang
Abstract:
Elastomeric materials when sliding on clean and rough surfaces generate wrinkles at the interface due to tangential stress gradients. These interfacial folds travel along the bottom of elastomer as surface detachment waves to facilitate the apparent sliding motion of elastomer. At very low sliding speed compared to elastic surface waves, the process is dominated by surface adhesion and relaxation…
▽ More
Elastomeric materials when sliding on clean and rough surfaces generate wrinkles at the interface due to tangential stress gradients. These interfacial folds travel along the bottom of elastomer as surface detachment waves to facilitate the apparent sliding motion of elastomer. At very low sliding speed compared to elastic surface waves, the process is dominated by surface adhesion and relaxation effects, and the phenomenon is historically referred to as Schallamach waves. We report in this letter the observation of fast-traveling intersonic detachment waves exceeding the Rayleigh and shear wave velocities of the soft material in contact. The spatio-temporal analysis revealed the accelerating nature of the detachment wave, and the scaling of wave speed with the elastic modului of the material suggests that this process is governed by elasticity and inertia. Multiple wave signatures on the plot were connected to different stages of surface wrinkles, as they exhibited distinctive slopes (from which velocities were derived) in the generation, propagation and rebound phases. We also characterized the frequencies of wrinkle generation in addition to the speeds and found a consistent scaling law of these two wave characteristics as the stiffness of elastomer increased. Physical implications of this new finding may further promote our understanding of elastomer noise generation mechanisms, as at macroscopic sliding velocity, the frequency of elastomer instability readily enters human audible ranges and interacts with other vibratory frequencies to cooperatively create harsh and detrimental noises in disc braking, wiper blade and shoe squeaking among many other elastomer applications.
△ Less
Submitted 26 October, 2021;
originally announced October 2021.
-
Objective task-based evaluation of artificial intelligence-based medical imaging methods: Framework, strategies and role of the physician
Authors:
Abhinav K. Jha,
Kyle J. Myers,
Nancy A. Obuchowski,
Ziping Liu,
Md Ashequr Rahman,
Babak Saboury,
Arman Rahmim,
Barry A. Siegel
Abstract:
Artificial intelligence (AI)-based methods are showing promise in multiple medical-imaging applications. Thus, there is substantial interest in clinical translation of these methods, requiring in turn, that they be evaluated rigorously. In this paper, our goal is to lay out a framework for objective task-based evaluation of AI methods. We will also provide a list of tools available in the literatu…
▽ More
Artificial intelligence (AI)-based methods are showing promise in multiple medical-imaging applications. Thus, there is substantial interest in clinical translation of these methods, requiring in turn, that they be evaluated rigorously. In this paper, our goal is to lay out a framework for objective task-based evaluation of AI methods. We will also provide a list of tools available in the literature to conduct this evaluation. Further, we outline the important role of physicians in conducting these evaluation studies. The examples in this paper will be proposed in the context of PET with a focus on neural-network-based methods. However, the framework is also applicable to evaluate other medical-imaging modalities and other types of AI methods.
△ Less
Submitted 20 July, 2021; v1 submitted 9 July, 2021;
originally announced July 2021.
-
Realising Einstein's mirror: Optomechanical damping with a thermal photon gas
Authors:
A. T. M. Anishur Rahman,
P. F. Barker
Abstract:
In 1909 Einstein described the thermalization of a mirror within a blackbody cavity by collisions with thermal photons. While the time to thermalize the motion of even a microscale or nanoscale object is so long that it is not feasible, we show that it is using the high intensity light from an amplified thermal light source with a well-defined chemical potential. We predict damping of the center-o…
▽ More
In 1909 Einstein described the thermalization of a mirror within a blackbody cavity by collisions with thermal photons. While the time to thermalize the motion of even a microscale or nanoscale object is so long that it is not feasible, we show that it is using the high intensity light from an amplified thermal light source with a well-defined chemical potential. We predict damping of the center-of mass motion due to this effect on times scales of seconds for small optomechanical systems, such as levitated nanoparticles, allowing experimental observation.
△ Less
Submitted 14 June, 2021; v1 submitted 6 April, 2021;
originally announced April 2021.
-
A physics and learning-based transmission-less attenuation compensation method for SPECT
Authors:
Zitong Yu,
Md Ashequr Rahman,
Thomas Schindler,
Richard Laforest,
Abhinav K. Jha
Abstract:
Attenuation compensation (AC) is a pre-requisite for reliable quantification and beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT). Typical AC methods require the availability of an attenuation map obtained using a transmission scan, such as a CT scan. This has several disadvantages such as increased radiation dose, higher costs, and possible misalign…
▽ More
Attenuation compensation (AC) is a pre-requisite for reliable quantification and beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT). Typical AC methods require the availability of an attenuation map obtained using a transmission scan, such as a CT scan. This has several disadvantages such as increased radiation dose, higher costs, and possible misalignment between SPECT and CT scans. Also, often a CT scan is unavailable. In this context, we and others are showing that scattered photons in SPECT contain information to estimate the attenuation distribution. To exploit this observation, we propose a physics and learning-based method that uses the SPECT emission data in the photopeak and scatter windows to perform transmission-less AC in SPECT. The proposed method uses data acquired in the scatter window to reconstruct an initial estimate of the attenuation map using a physics-based approach. A convolutional neural network is then trained to segment this initial estimate into different regions. Pre-defined attenuation coefficients are assigned to these regions, yielding the reconstructed attenuation map, which is then used to reconstruct the activity map using an ordered subsets expectation maximization-based reconstruction approach. We objectively evaluated the performance of this method using a highly realistic simulation study conducted on the clinically relevant task of detecting perfusion defects in myocardial perfusion SPECT. Our results showed no statistically significant differences between the performance achieved using the proposed method and that with the true attenuation maps. Visually, the images reconstructed using the proposed method looked similar to those with the true attenuation map. Overall, these results provide evidence of the capability of the proposed method to perform transmission-less AC and motivate further evaluation.
△ Less
Submitted 11 February, 2021; v1 submitted 10 February, 2021;
originally announced February 2021.
-
Task-based assessment of binned and list-mode SPECT systems
Authors:
Md Ashequr Rahman,
Abhinav K. Jha
Abstract:
In SPECT, list-mode (LM) format allows storing data at higher precision compared to binned data. There is significant interest in investigating whether this higher precision translates to improved performance on clinical tasks. Towards this goal, in this study, we quantitatively investigated whether processing data in LM format, and in particular, the energy attribute of the detected photon, provi…
▽ More
In SPECT, list-mode (LM) format allows storing data at higher precision compared to binned data. There is significant interest in investigating whether this higher precision translates to improved performance on clinical tasks. Towards this goal, in this study, we quantitatively investigated whether processing data in LM format, and in particular, the energy attribute of the detected photon, provides improved performance on the task of absolute quantification of region-of-interest (ROI) uptake in comparison to processing the data in binned format. We conducted this evaluation study using a DaTscan brain SPECT acquisition protocol, conducted in the context of imaging patients with Parkinson's disease. This study was conducted with a synthetic phantom. A signal-known exactly/background-known-statistically (SKE/BKS) setup was considered. An ordered-subset expectation-maximization algorithm was used to reconstruct images from data acquired in LM format, including the scatter-window data, and including the energy attribute of each LM event. Using a realistic 2-D SPECT system simulation, quantification tasks were performed on the reconstructed images. The results demonstrated improved quantification performance when LM data was used compared to binning the attributes in all the conducted evaluation studies. Overall, we observed that LM data, including the energy attribute, yielded improved performance on absolute quantification tasks compared to binned data.
△ Less
Submitted 11 February, 2021; v1 submitted 7 February, 2021;
originally announced February 2021.
-
Comparison of phase change process in Si-GST hybrid integrated waveguide and MMI devices
Authors:
Hanyu Zhang,
Xing Yang,
Liangjun Lu,
Jianping Chen,
B. M. A. Rahman,
Linjie Zhou
Abstract:
In the past decades, silicon photonic integrated circuits (PICs) have been considered as a promising approach to solve the bandwidth bottleneck in optical communications and interconnections. Despite significant advances, large-scale PICs still face a series of technical challenges, such as footprint, power consumption, and routing state storage, resulting from the active tuning methods used to co…
▽ More
In the past decades, silicon photonic integrated circuits (PICs) have been considered as a promising approach to solve the bandwidth bottleneck in optical communications and interconnections. Despite significant advances, large-scale PICs still face a series of technical challenges, such as footprint, power consumption, and routing state storage, resulting from the active tuning methods used to control the optical waves. These challenges can be partially addressed by combining chalcogenide phase change materials (PCMs) such as Ge2Sb2Te5 (GST) with silicon photonics, especially applicable in switching applications due to the nonvolatile nature of the GST. Although GST phase transitions between amorphous and crystalline states actuated by optical and electrical pulses heating have been experimentally demonstrated, there is no direct comparison between them. We carried out simulations and experiments to systematically investigate the difference in the phase change process induced by optical and electrical pulses for two types of Si-GST hybrid waveguides. For the phase transition induced by optical pulses, the device has a clear advantage in terms of power consumption and operation speed. For the phase transition induced by electrical pulses, the device is suitable for large-scale integration because it does not require complex light routing. It helps us better understand the phase change process and push forward the further development of Si-GST hybrid integration platform, bringing in new potential applications.
△ Less
Submitted 18 September, 2020;
originally announced September 2020.
-
A list-mode OSEM-based attenuation and scatter compensation method for SPECT
Authors:
Md Ashequr Rahman,
Richard Laforest,
Abhinav K. Jha
Abstract:
Reliable attenuation and scatter compensation (ASC) is a prerequisite for quantification and beneficial for visual interpretation tasks in SPECT. In this paper, we develop a reconstruction method that uses the entire SPECT emission data, i.e. data in both the photopeak and scatter windows, acquired in list-mode format and including the energy attribute of the detected photon, to perform ASC. We im…
▽ More
Reliable attenuation and scatter compensation (ASC) is a prerequisite for quantification and beneficial for visual interpretation tasks in SPECT. In this paper, we develop a reconstruction method that uses the entire SPECT emission data, i.e. data in both the photopeak and scatter windows, acquired in list-mode format and including the energy attribute of the detected photon, to perform ASC. We implemented a GPU-based version of this method using an ordered subsets expectation maximization (OSEM) algorithm. The method was objectively evaluated using realistic simulation studies on the task of estimating uptake in the striatal regions of the brain in a 2-D dopamine transporter (DaT)-scan SPECT study. We observed that inclusion of data from the scatter window and using list-mode data yielded improved quantification compared to using data only from the photopeak window or using binned data. These results motivate further development of list-mode-based ASC methods that include scatter-window data for SPECT.
△ Less
Submitted 27 February, 2020;
originally announced February 2020.
-
Optical levitation using broadband light
Authors:
A. T. M. Anishur Rahman,
P. F. Barker
Abstract:
The ability to create dynamic, tailored optical potentials has become important across fields ranging from biology to quantum science. We demonstrate a method for the creation of arbitrary optical tweezer potentials using the broadband spectral profile of a superluminescent diode combined with the chromatic aberration of a lens. A tunable filter, typically used for ultra-fast laser pulse shaping,…
▽ More
The ability to create dynamic, tailored optical potentials has become important across fields ranging from biology to quantum science. We demonstrate a method for the creation of arbitrary optical tweezer potentials using the broadband spectral profile of a superluminescent diode combined with the chromatic aberration of a lens. A tunable filter, typically used for ultra-fast laser pulse shaping, allows us to manipulate the broad spectral profile and therefore the optical tweezer potentials formed by focusing of this light. We characterize these potentials by measuring the Brownian motion of levitated nanoparticles in vacuum and, also demonstrate interferometric detection and feedback cooling of the particle,s motion. This simple and cost-effective technique will enable a wide range of applications and allow rapid modulation of the optical potential landscape in excess of MHz frequencies.
△ Less
Submitted 14 July, 2020; v1 submitted 11 February, 2020;
originally announced February 2020.
-
Miniature Multi-Level Optical Memristive Switch Using Phase Change Material
Authors:
Hanyu Zhang,
Linjie Zhou,
Liangjun Lu,
Jian Xu,
Ningning Wang,
Hao Hu,
B. M. A. Rahman,
Zhiping Zhou,
Jianping Chen
Abstract:
The optical memristive switches are electrically activated optical switches that can memorize the current state. They can be used as optical latching switches in which the switching state is changed only by applying an electrical Write/Erase pulse and maintained without external power supply. We demonstrate an optical memristive switch based on a silicon MMI structure covered with nanoscale-size G…
▽ More
The optical memristive switches are electrically activated optical switches that can memorize the current state. They can be used as optical latching switches in which the switching state is changed only by applying an electrical Write/Erase pulse and maintained without external power supply. We demonstrate an optical memristive switch based on a silicon MMI structure covered with nanoscale-size Ge2Sb2Te5 (GST) material on top. The phase change of GST is triggered by resistive heating of the silicon layer beneath GST with an electrical pulse. Experimental results reveal that the optical transmissivity can be tuned in a controllable and repeatable manner with the maximum transmission contrast exceeding 20 dB. Partial crystallization of GST is obtained by controlling the width and amplitude of the electric pulses. Crucially, we also demonstrate that both Erase and Write operations, to and from any intermediate level, are possible with accurate control of the electrical pulses. Our work marks a significant step forward towards realizing photonic memristive switches without static power consumption, which are highly demanded in high-density large-scale integrated photonics.
△ Less
Submitted 8 May, 2019;
originally announced May 2019.
-
Fisher information analysis of list-mode SPECT emission data for joint estimation of activity and attenuation distribution
Authors:
Md Ashequr Rahman,
Yansong Zhu,
Eric Clarkson,
Matthew A. Kupinski,
Eric C. Frey,
Abhinav K. Jha
Abstract:
The potential to perform attenuation and scatter compensation (ASC) in single-photon emission computed tomography (SPECT) imaging using only the SPECT emission data is highly significant. In this context, attenuation in SPECT is primarily due to Compton scattering, where the probability of Compton scatter is proportional to the attenuation coefficient of the tissue and the energy of the scattered…
▽ More
The potential to perform attenuation and scatter compensation (ASC) in single-photon emission computed tomography (SPECT) imaging using only the SPECT emission data is highly significant. In this context, attenuation in SPECT is primarily due to Compton scattering, where the probability of Compton scatter is proportional to the attenuation coefficient of the tissue and the energy of the scattered photon and the scattering angle are related. Given this premise, we investigate whether the SPECT scattered-photon data acquired in list-mode (LM) format and including the energy information can be used to estimate the attenuation map. For this purpose, we propose a Fisher-information-based method that yields the Cramer-Rao bound (CRB) for the task of jointly estimating the activity/attenuation distribution using only the SPECT emission data. The proposed method is applied to analyze the information content of SPECT LM emission data in a 2D SPECT system using computational studies with digital phantoms for different photon-count levels. The results show that scattered photons contain information to estimate the attenuation coefficients. An increase in the number of detected photons leads to lower CRB for both the attenuation and activity coefficients. Also, the CRB obtained for the attenuation and activity coefficients is typically much lower than the true value of these coefficients. Further, processing the emission data in LM format yields a lower CRB in comparison to binning data. Finally, we observe that systems with better energy resolution yield a lower CRB for the attenuation coefficient. Overall, the results provide strong evidence that LM SPECT emission data, including the scattered photons, contains information to jointly estimate the activity and attenuation coefficients.
△ Less
Submitted 30 January, 2020; v1 submitted 4 July, 2018;
originally announced July 2018.
-
An analytical model for the detection of levitated nanoparticles in optomechanics
Authors:
A. T. M. Anishur Rahman,
A. C. Frangeskou,
P. F. Barker,
G. W. Morley
Abstract:
Interferometric position detection of levitated particles is crucial for the centre-of-mass (CM) motion cooling and manipulation of levitated particles. In combination with balanced detection and feedback cooling, this system has provided picometer scale position sensitivity, zeptonewton force detection, and sub-millikelvin CM temperatures. In this article, we develop an analytical model of this d…
▽ More
Interferometric position detection of levitated particles is crucial for the centre-of-mass (CM) motion cooling and manipulation of levitated particles. In combination with balanced detection and feedback cooling, this system has provided picometer scale position sensitivity, zeptonewton force detection, and sub-millikelvin CM temperatures. In this article, we develop an analytical model of this detection system and compare its performance with experimental results allowing us to explain the presence of spurious frequencies in the spectra.
△ Less
Submitted 15 January, 2018; v1 submitted 2 October, 2017;
originally announced October 2017.
-
A laser cooled nanocryostat: Refrigeration, alignment and rotation of levitated Yb$^{+3}$:YLF nanocrystals
Authors:
A. T. M. Anishur Rahman,
P. F. Barker
Abstract:
The ability to cool and manipulate levitated nano-particles in vacuum is a promising new tool for exploring macroscopic quantum mechanics\cite{WanPRL2016,Scala2013,Zhang2013}, precision measurements of forces, \cite{GambhirPRA2016} and non-equilibrium thermodynamics \cite{GieselerNatNano2014,MillenNat2014}. The extreme isolation afforded by optical levitation offers a low noise, undamped environme…
▽ More
The ability to cool and manipulate levitated nano-particles in vacuum is a promising new tool for exploring macroscopic quantum mechanics\cite{WanPRL2016,Scala2013,Zhang2013}, precision measurements of forces, \cite{GambhirPRA2016} and non-equilibrium thermodynamics \cite{GieselerNatNano2014,MillenNat2014}. The extreme isolation afforded by optical levitation offers a low noise, undamped environment that has to date been used to measure zeptonewton forces \cite{GambhirPRA2016}, radiation pressure shot noise,\cite{Jain2016} and to demonstrate the cooling of the centre-of-mass motion \cite{LiNatPhys2011,Gieseler2012}. Ground state cooling, and the creation and measurement of macroscopic quantum superpositions, are now within reach, but control of both the center-of-mass and internal temperature is required. While cooling the centre-of-mass motion to microKelvin temperatures has now been achieved, the internal temperature has remained at or well above room temperature. Here we demonstrate refrigeration of levitated Yb$^{3+}$:YLF from room temperature to 130 K using anti-Stokes fluorescence cooling, while simultaneously using the optical trapping field to align the crystal to maximise cooling.
△ Less
Submitted 21 March, 2017;
originally announced March 2017.
-
Optical levitation of high purity nanodiamonds in vacuum without heating
Authors:
A. C. Frangeskou,
A. T. M. A. Rahman,
L. Gines,
S. Mandal,
O. A. Williams,
P. F. Barker,
G. W. Morley
Abstract:
Levitated nanodiamonds containing nitrogen vacancy centres in high vacuum are a potential test bed for numerous phenomena in fundamental physics. However, experiments so far have been limited to low vacuum due to heating arising from optical absorption of the trapping laser. We show that milling pure diamond creates nanodiamonds that do not heat up as the optical intensity is raised above 700 GW/m…
▽ More
Levitated nanodiamonds containing nitrogen vacancy centres in high vacuum are a potential test bed for numerous phenomena in fundamental physics. However, experiments so far have been limited to low vacuum due to heating arising from optical absorption of the trapping laser. We show that milling pure diamond creates nanodiamonds that do not heat up as the optical intensity is raised above 700 GW/m$^2$ below 5 mbar of pressure. This advance now means that the level of attainable vacuum for nanodiamonds in optical dipole traps is no longer temperature limited.
△ Less
Submitted 16 August, 2016;
originally announced August 2016.
-
Burning and graphitization of optically levitated nanodiamonds in vacuum
Authors:
A. T. M. A. Rahman,
A. Frangeskou,
M. S. Kim,
S. Bose,
G. W. Morley,
P. F. Barker
Abstract:
A nitrogen-vacancy (NV$^-$) center in a nanodiamond, levitated in high vacuum, has recently been proposed as a probe for demonstrating mesoscopic center-of-mass superpositions \cite{Scala2013, Zhang2013} and for testing quantum gravity \cite{Albrecht2014}. Here, we study the behavior of optically levitated nanodiamonds containing NV$^-$ centers at sub-atmospheric pressures and show that while they…
▽ More
A nitrogen-vacancy (NV$^-$) center in a nanodiamond, levitated in high vacuum, has recently been proposed as a probe for demonstrating mesoscopic center-of-mass superpositions \cite{Scala2013, Zhang2013} and for testing quantum gravity \cite{Albrecht2014}. Here, we study the behavior of optically levitated nanodiamonds containing NV$^-$ centers at sub-atmospheric pressures and show that while they burn in air, this can be prevented by replacing the air with nitrogen. However, in nitrogen the nanodiamonds graphitize below $\approx 10$ mB. Exploiting the Brownian motion of a levitated nanodiamond, we extract its internal temperature ($T_i$) and find that it would be detrimental to the NV$^-$ center's spin coherence time \cite{Toyli2012}. These values of $T_i$ make it clear that the diamond is not melting, contradicting a recent suggestion \cite{Neukirch2015}. Additionally, using the measured damping rate of a levitated nanoparticle at a given pressure, we propose a new way of determining its size.
△ Less
Submitted 26 October, 2015;
originally announced October 2015.
-
Specialty Fibers for Terahertz Generation and Transmission: A Review
Authors:
Ajanta Barh,
B. P. Pal,
G. P. Agrawal,
R. K. Varshney,
B. M. A. Rahman
Abstract:
Terahertz (THz) frequency range, lying between the optical and microwave range covers a significant portion of the electro-magnetic spectrum. Though its initial usage started in the 1960s, active research in the THz field started only in the 1990s by researchers from both optics and microwaves disciplines. The use of optical fibers for THz application has attracted considerable attention in recent…
▽ More
Terahertz (THz) frequency range, lying between the optical and microwave range covers a significant portion of the electro-magnetic spectrum. Though its initial usage started in the 1960s, active research in the THz field started only in the 1990s by researchers from both optics and microwaves disciplines. The use of optical fibers for THz application has attracted considerable attention in recent years. In this article, we review the progress and current status of optical fiber-based techniques for THz generation and transmission. The first part of this review focuses on THz sources. After a review on various types of THz sources, we discuss how specialty optical fibers can be used for THz generation. The second part of this review focuses on the guided wave propagation of THz waves for their transmission. After discussing various wave guiding schemes, we consider new fiber designs for THz transmission.
△ Less
Submitted 10 June, 2015;
originally announced June 2015.
-
Transmission and Reflection through $1$D Metallo-Dielectric Gratings of Real Metals under Sub-wavelength Condition
Authors:
A. T. M. Anishur Rahman,
Peter Majewski,
Krasimir Vasilev
Abstract:
Under the sub-wavelength condition ($w<λ/2$), an analytical model of light transmission and reflection through $1$D metallo-dielectric gratings of real metals has been developed. It has been shown that the transmission intensity associated with the Fabry-Perot (FP) resonance of a $1$D metallo-dielectric grating of a real metal decreases with the increasing grating thickness and the dielectric cons…
▽ More
Under the sub-wavelength condition ($w<λ/2$), an analytical model of light transmission and reflection through $1$D metallo-dielectric gratings of real metals has been developed. It has been shown that the transmission intensity associated with the Fabry-Perot (FP) resonance of a $1$D metallo-dielectric grating of a real metal decreases with the increasing grating thickness and the dielectric constant of the ridge material. Further, it has also been demonstrated that the intensity of the FP resonance increases with the increasing slit width while it is independent of the grating period ($P$) and the incidence angle (when $P << λ$
△ Less
Submitted 3 June, 2015;
originally announced June 2015.
-
Extraordinary Optical Transmission: Coupling of the Wood-Rayleigh anomaly and the Fabry-Perot resonance
Authors:
A. T. M. Anishur Rahman,
Peter Majewski,
Krasimir Vasilev
Abstract:
In this letter, we demonstrate for the first time that by combining the effects of the Wood-Rayleigh Anomaly (WRA) and the Fabry-Perot (FP) resonance, transmission efficiencies of $1$D metallo-dielectric gratings on substrates can be significantly improved compared to when these two phenomena work separately. Results of combining the WRA and the FP resonance can be utilized to eliminate the necess…
▽ More
In this letter, we demonstrate for the first time that by combining the effects of the Wood-Rayleigh Anomaly (WRA) and the Fabry-Perot (FP) resonance, transmission efficiencies of $1$D metallo-dielectric gratings on substrates can be significantly improved compared to when these two phenomena work separately. Results of combining the WRA and the FP resonance can be utilized to eliminate the necessity of using the index matching technique and the core-shell structure for enhancing the performance of extraordinary optical transmission devices. Further, the outcomes of combining the WRA and the FP resonance can elucidate some of the unexplained results in the literature.
△ Less
Submitted 3 June, 2015;
originally announced June 2015.
-
Analytical solution of the fundamental waveguide mode of one-dimensional transmission grating for TM polarization
Authors:
A. T. M. Anishur Rahman,
Krasimir Vasilev,
Peter Majewski
Abstract:
This article presents an analytical solution of the effective index of the fundamental waveguide mode of $1$D metallo-dielectric grating for Transverse Magnetic (TM) polarization. In contrast to the existing numerical solution involving transcendental equation, it is shown that the square of the effective index ($n_{Eff}$) of the fundamental waveguide mode of $1$D grating is inversely proportional…
▽ More
This article presents an analytical solution of the effective index of the fundamental waveguide mode of $1$D metallo-dielectric grating for Transverse Magnetic (TM) polarization. In contrast to the existing numerical solution involving transcendental equation, it is shown that the square of the effective index ($n_{Eff}$) of the fundamental waveguide mode of $1$D grating is inversely proportional to the slit width ($w$) and the refractive index ($n_m$) of the ridge material and varies linearly with the incident wavelength ($λ$). Further, it has also been demonstrated that the dependence of $n_{Eff}$ on the grating period ($P$) and the incidence angle ($θ$) is minimal. Agreement between the results obtained using the solution presented in this article and published data is excellent.
△ Less
Submitted 3 June, 2015;
originally announced June 2015.