Characterization of iLGADs using soft X-rays
Authors:
Antonio Liguori,
Rebecca Barten,
Filippo Baruffaldi,
Anna Bergamaschi,
Giacomo Borghi,
Maurizio Boscardin,
Martin Brückner,
Tim Alexander Butcher,
Maria Carulla,
Matteo Centis Vignali,
Roberto Dinapoli,
Simon Ebner,
Francesco Ficorella,
Erik Fröjdh,
Dominic Greiffenberg,
Omar Hammad Ali,
Shqipe Hasanaj,
Julian Heymes,
Viktoria Hinger,
Thomas King,
Pawel Kozlowski,
Carlos Lopez-Cuenca,
Davide Mezza,
Konstantinos Moustakas,
Aldo Mozzanica
, et al. (9 additional authors not shown)
Abstract:
Experiments at synchrotron radiation sources and X-ray Free-Electron Lasers in the soft X-ray energy range ($250$eV--$2$keV) stand to benefit from the adaptation of the hybrid silicon detector technology for low energy photons. Inverse Low Gain Avalanche Diode (iLGAD) sensors provide an internal gain, enhancing the signal-to-noise ratio and allowing single photon detection below $1$keV using hybri…
▽ More
Experiments at synchrotron radiation sources and X-ray Free-Electron Lasers in the soft X-ray energy range ($250$eV--$2$keV) stand to benefit from the adaptation of the hybrid silicon detector technology for low energy photons. Inverse Low Gain Avalanche Diode (iLGAD) sensors provide an internal gain, enhancing the signal-to-noise ratio and allowing single photon detection below $1$keV using hybrid detectors. In addition, an optimization of the entrance window of these sensors enhances their quantum efficiency (QE). In this work, the QE and the gain of a batch of different iLGAD diodes with optimized entrance windows were characterized using soft X-rays at the Surface/Interface:Microscopy beamline of the Swiss Light Source synchrotron. Above $250$eV, the QE is larger than $55\%$ for all sensor variations, while the charge collection efficiency is close to $100\%$. The average gain depends on the gain layer design of the iLGADs and increases with photon energy. A fitting procedure is introduced to extract the multiplication factor as a function of the absorption depth of X-ray photons inside the sensors. In particular, the multiplication factors for electron- and hole-triggered avalanches are estimated, corresponding to photon absorption beyond or before the gain layer, respectively.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.
-
Results and Limits of Time Division Multiplexing for the BICEP Array High Frequency Receivers
Authors:
S. Fatigoni,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
D. Beck,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. J. Cukierman,
E. V. Denison,
M. I. Dierickx,
L. Duband,
M. Eiben,
J. P. Filippini,
A. Fortes,
M. Gao,
C. Giannakopoulos,
N. Goeckner-Wald,
D. C. Goldfinger
, et al. (62 additional authors not shown)
Abstract:
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the…
▽ More
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard Multi Channel Electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates Time Division Multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and crosstalk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Future experiments like CMB-S4 plan to use TES bolometers with Time Division/SQUID-based readout for an even larger number of detectors.
△ Less
Submitted 24 October, 2023; v1 submitted 16 October, 2023;
originally announced October 2023.
-
Detection of MeV electrons using a charge integrating hybrid pixel detector
Authors:
E. Fröjdh,
F. Baruffaldi,
A. Bergamaschi,
M. Carulla,
R. Dinapoli,
D. Greiffenberg,
J. Heymes,
V. Hinger,
R. Ischebeck,
S. Mathisen,
J. McKenzie,
D. Mezza,
K. Moustakas,
A. Mozzanica,
B. Schmitt,
J. Zhang
Abstract:
Electrons are emerging as a strong complement to X-rays for diffraction based studies. In this paper we investigate the performance of a JUNGFRAU detector with 320 um thick silicon sensor at a pulsed electron source. Originally developed for X-ray detection at free electron lasers, JUNGFRAU features a dynamic range of 120 MeV/pixel (implemented with in-pixel gain switching) which translated to abo…
▽ More
Electrons are emerging as a strong complement to X-rays for diffraction based studies. In this paper we investigate the performance of a JUNGFRAU detector with 320 um thick silicon sensor at a pulsed electron source. Originally developed for X-ray detection at free electron lasers, JUNGFRAU features a dynamic range of 120 MeV/pixel (implemented with in-pixel gain switching) which translated to about 1200 incident electrons per pixel and frame in the MeV region. We preset basic characteristics such as energy deposited per incident particle, resulting cluster size and spatial resolution along with dynamic (intensity) range scans. Measurements were performed at 4, 10 and 20 MeV/c. We compare the measurements with GEANT4 based simulations and extrapolate the results to different sensor thicknesses using these simulations.
△ Less
Submitted 28 October, 2022;
originally announced October 2022.
-
Development of LGAD sensors with a thin entrance window for soft X-ray detection
Authors:
Jiaguo Zhang,
Rebecca Barten,
Filippo Baruffaldi,
Anna Bergamaschi,
Giacomo Borghi,
Maurizio Boscardin,
Martin Brueckner,
Maria Carulla,
Matteo Centis Vignali,
Roberto Dinapoli,
Simon Ebner,
Francesco Ficorella,
Erik Froejdh,
Dominic Greiffenberg,
Omar Hammad Ali,
Julian Heymes,
Shqipe Hasanaj,
Viktoria Hinger,
Thomas King,
Pawel Kozlowski,
Carlos Lopez-Cuenca,
Davide Mezza,
Konstantinos Moustakas,
Aldo Mozzanica,
Giovanni Paternoster
, et al. (4 additional authors not shown)
Abstract:
We show the developments carried out to improve the silicon sensor technology for the detection of soft X-rays with hybrid X-ray detectors. An optimization of the entrance window technology is required to improve the quantum efficiency. The LGAD technology can be used to amplify the signal generated by the X-rays and to increase the signal-to-noise ratio, making single photon resolution in the sof…
▽ More
We show the developments carried out to improve the silicon sensor technology for the detection of soft X-rays with hybrid X-ray detectors. An optimization of the entrance window technology is required to improve the quantum efficiency. The LGAD technology can be used to amplify the signal generated by the X-rays and to increase the signal-to-noise ratio, making single photon resolution in the soft X-ray energy range possible. In this paper, we report first results obtained from an LGAD sensor production with an optimized thin entrance window. Single photon detection of soft X-rays down to 452~eV has been demonstrated from measurements, with a signal-to-noise ratio better than 20.
△ Less
Submitted 24 October, 2022;
originally announced October 2022.
-
Krylov Methods for Adjoint-Free Singular Vector Based Perturbations in Dynamical Systems
Authors:
Jens Winkler,
Michael Denhard,
Bernhard A. Schmitt
Abstract:
The estimation of weather forecast uncertainty with ensemble systems requires a careful selection of perturbations to establish a reliable sampling of the error growth potential in the phase space of the model. Usually, the singular vectors of the tangent linear model propagator are used to identify the fastest growing modes (classical singular vector perturbation (SV) method). In this paper we pr…
▽ More
The estimation of weather forecast uncertainty with ensemble systems requires a careful selection of perturbations to establish a reliable sampling of the error growth potential in the phase space of the model. Usually, the singular vectors of the tangent linear model propagator are used to identify the fastest growing modes (classical singular vector perturbation (SV) method). In this paper we present an efficient matrix-free block Krylov method for generating fast growing perturbations in high dimensional dynamical systems. A specific matrix containing the non-linear evolution of perturbations is introduced, which we call Evolved Increment Matrix (EIM). Instead of solving an equivalent eigenvalue problem, we use the Arnoldi method for a direct approximation of the leading singular vectors of this matrix, which however is never computed explicitly. This avoids linear and adjoint models but requires forecasts with the full non-linear system. The performance of the approximated perturbations is compared with singular vectors of a full EIM (not with the classical SV method). We show promising results for the Lorenz96 differential equations and a shallow water model, where we obtain good approximations of the fastest growing perturbations by using only a small number of Arnoldi iterations.
△ Less
Submitted 13 September, 2022;
originally announced September 2022.
-
Design and first tests of the Gotthard-II readout ASIC for the European X-ray Free-Electron Laser
Authors:
Jiaguo Zhang,
Marie Andrae,
Rebecca Barten,
Anna Bergamaschi,
Martin Brueckner,
Sabina Chiriotti-Alvarez,
Roberto Dinapoli,
Erik Froejdh,
Dominic Greiffenberg,
Pawel Kozlowski,
Markus Kuster,
Carlos Lopez-Cuenca,
Markus Meyer,
Davide Mezza,
Aldo Mozzanica,
Marco Ramilli,
Christian Ruder,
Bernd Schmitt,
Xintian Shi,
Dhanya Thattil,
Gemma Tinti,
Monica Turcato,
Seraphin Vetter
Abstract:
Gotthard-II is a charge-integrating microstrip detector developed for experiments and diagnostics at free-electron lasers using hard X-rays of 5 keV - 20 keV. Thanks to its excellent single photon sensitivity, large dynamic range as well as high frame rate of 4.5 MHz in burst mode, its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution sing…
▽ More
Gotthard-II is a charge-integrating microstrip detector developed for experiments and diagnostics at free-electron lasers using hard X-rays of 5 keV - 20 keV. Thanks to its excellent single photon sensitivity, large dynamic range as well as high frame rate of 4.5 MHz in burst mode, its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), beam diagnostics, as well as veto signal generation for pixel detectors. The Gotthard-II ASIC has been designed and fabricated using UMC-110 nm technology. The final ASIC design and performance in terms of noise, linearity, dynamic range, coupling between channels and speed will be discussed in the paper. In addition, a first measurement of an X-ray absorption spectrum of a standard copper sample has been done. The performance of the Gotthard-II in an experiment using energy dispersive X-rays has been demonstrated.
△ Less
Submitted 29 March, 2021;
originally announced March 2021.
-
Receiver development for BICEP Array, a next-generation CMB polarimeter at the South Pole
Authors:
L. Moncelsi,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
E. V. Denison,
M. Dierickx,
L. Duband,
M. Eiben,
S. Fatigoni,
J. P. Filippini,
N. Goeckner-Wald,
D. C. Goldfinger,
J. Grayson,
P. Grimes,
G. Hall
, et al. (50 additional authors not shown)
Abstract:
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date…
▽ More
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date. BICEP Array (BA) is the Stage-3 instrument of the BK program and will comprise four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz with a combined 32,000+ detectors; such wide frequency coverage is necessary for control of the Galactic foregrounds, which also produce degree-scale $B$-mode signal. The 30/40 GHz receiver is designed to constrain the synchrotron foreground and has begun observing at the South Pole in early 2020. By the end of a 3-year observing campaign, the full BICEP Array instrument is projected to reach $σ_r$ between 0.002 and 0.004, depending on foreground complexity and degree of removal of $B$-modes due to gravitational lensing (delensing). This paper presents an overview of the design, measured on-sky performance and calibration of the first BA receiver. We also give a preview of the added complexity in the time-domain multiplexed readout of the 7,776-detector 150 GHz receiver.
△ Less
Submitted 7 December, 2020;
originally announced December 2020.
-
Modeling Pluto's Minimum Pressure: Implications for Haze Production
Authors:
Perianne E. Johnson,
Leslie A. Young,
Silvia Protopapa,
Bernard Schmitt,
Leila R. Gabasova,
Briley L. Lewis,
John A. Stansberry,
Kathy E. Mandt,
Oliver L. White
Abstract:
Pluto has a heterogeneous surface, despite a global haze deposition rate of ~1 micrometer per orbit (Cheng et al., 2017; Grundy et al., 2018). While there could be spatial variation in the deposition rate, this has not yet been rigorously quantified, and naively the haze should coat the surface more uniformly than was observed. One way (among many) to explain this contradiction is for atmospheric…
▽ More
Pluto has a heterogeneous surface, despite a global haze deposition rate of ~1 micrometer per orbit (Cheng et al., 2017; Grundy et al., 2018). While there could be spatial variation in the deposition rate, this has not yet been rigorously quantified, and naively the haze should coat the surface more uniformly than was observed. One way (among many) to explain this contradiction is for atmospheric pressure at the surface to drop low enough to interrupt haze production and stop the deposition of particles onto part of the surface, driving heterogeneity. If the surface pressure drops to less than 10^-3 - 10^-4 microbar and the CH4 mixing ratio remains nearly constant at the observed 2015 value, the atmosphere becomes transparent to ultraviolet radiation (Young et al., 2018), which would shut off haze production at its source. If the surface pressure falls below 0.06 microbar, the atmosphere ceases to be global, and instead is localized over only the warmest part of the surface, restricting the location of deposition (Spencer et al., 1997). In Pluto's current atmosphere, haze monomers collect together into aggregate particles at beginning at 0.5 microbar; if the surface pressure falls below this limit, the appearance of particles deposited at different times of year and in different locations could be different. We use VT3D, an energy balance model (Young, 2017), to model the surface pressure on Pluto in current and past orbital configurations for four possible static N2 ice distributions: the observed northern hemisphere distribution with (1) a bare southern hemisphere, (2) a south polar cap, (3) a southern zonal band, and finally (4) a distribution that is bare everywhere except inside the boundary of Sputnik Planitia. We also present a sensitivity study showing the effect of mobile N2 ice...(cont.)
△ Less
Submitted 24 August, 2020;
originally announced August 2020.
-
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Authors:
C. Zhang,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
H. Boenish,
E. Bullock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
M. Dierickx,
L. Duband,
S. Fatigoni,
J. P. Filippini,
G. Hall,
M. Halpern,
S. Harrison,
S. Henderson,
S. R. Hildebrandt
, et al. (44 additional authors not shown)
Abstract:
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of grav…
▽ More
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of gravitational lensing polarization. The 30/40 GHz receiver of the BICEP Array (BA) will deploy at the end of 2019 and will constrain the synchrotron foreground with unprecedented accuracy within the BK sky patch. We will show the design of the 30/40 GHz detectors and test results summarizing its performance. The low optical and atmospheric loading at these frequencies requires our TES detectors to have low saturation power in order to be photon-noise dominated. To realize the low thermal conductivity required from a 250 mK base temperature, we developed new bolometer leg designs. We will present the relevant measured detector parameters: G, Tc, Rn, Psat , and spectral bands, and noise spectra. We achieved a per bolometer NEP including all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon noise level 1.54E-17 W/sqrt(Hz).
△ Less
Submitted 12 February, 2020;
originally announced February 2020.
-
Megapixels @ Megahertz -- The AGIPD High-Speed Cameras for the European XFEL
Authors:
Ulrich Trunk,
Aschkan Allahgholi,
Julian Becker,
Annette Delfs,
Roberto Dinapoli,
Peter Göttlicher,
Heinz Graafsma,
Dominic Greiffenberg,
Helmut Hirsemann,
Stefanie Jack,
Alexander Klyuev,
Hans Krüger,
Manuela Kuhn,
Torsten Laurus,
Alessandro Marras,
Davide Mezza,
Aldo Mozzanica,
Jennifer Poehlsen,
Ofir Shefer Shalev,
Igor Sheviakov,
Bernd Schmitt,
Jörn Schwandt,
Xintian Shi,
Sergej Smoljanin,
Jiaguo Zhang
, et al. (1 additional authors not shown)
Abstract:
The European XFEL is an extremely brilliant Free Electron Laser Source with a very demanding pulse structure: trains of 2700 X-Ray pulses are repeated at 10 Hz. The pulses inside the train are spaced by 220 ns and each one contains up to $10^{12}$ photons of 12.4 keV, while being $\le 100$ fs in length. AGIPD, the Adaptive Gain Integrating Pixel Detector, is a hybrid pixel detector developed by DE…
▽ More
The European XFEL is an extremely brilliant Free Electron Laser Source with a very demanding pulse structure: trains of 2700 X-Ray pulses are repeated at 10 Hz. The pulses inside the train are spaced by 220 ns and each one contains up to $10^{12}$ photons of 12.4 keV, while being $\le 100$ fs in length. AGIPD, the Adaptive Gain Integrating Pixel Detector, is a hybrid pixel detector developed by DESY, PSI, and the Universities of Bonn and Hamburg to cope with these properties. It is a fast, low noise integrating detector, with single photon sensitivity (for $\text{E}_γ \ge 6$ keV) and a large dynamic range, up to $10^4$ photons at 12.4 keV. This is achieved with a charge sensitive amplifier with 3 adaptively selected gains per pixel. 352 images can be recorded at up to 6.5 MHz and stored in the in-pixel analogue memory and read out between pulse trains. The core component of this detector is the AGIPD ASIC, which consists of $64 \times 64$ pixels of $200 μ\text{m} \times 200 μ\text{m}$. Control of the ASIC's image acquisition and analogue readout is via a command based interface. FPGA based electronic boards, controlling ASIC operation, image digitisation and 10 GE data transmission interface AGIPD detectors to DAQ and control systems. An AGIPD 1 Mpixel detector has been installed at the SPB experimental station in August 2017, while a second one is currently commissioned for the MID endstation. A larger (4 Mpixel) AGIPD detector and one to employ Hi-Z sensor material to efficiently register photons up to $\text{E}_γ \approx 25$ keV are currently under construction.
△ Less
Submitted 6 August, 2019;
originally announced August 2019.
-
Performance Evaluation of the Analogue Front-End and ADC Prototypes for the Gotthard-II Development
Authors:
Jiaguo Zhang,
Marie Andrä,
Rebecca Barten,
Anna Bergamaschi,
Martin Brückner,
Roberto Dinapoli,
Erik Fröjdh,
Dominic Greiffenberg,
Carlos Lopez-Cuenca,
Davide Mezza,
Aldo Mozzanica,
Marco Ramilli,
Sophie Redford,
Marie Ruat,
Christian Ruder,
Bernd Schmitt,
Xintian Shi,
Dhanya Thattil,
Gemma Tinti,
Monica Turcato,
Seraphin Vettera
Abstract:
Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), energy dispersive experiments at 4.5 MHz frame rate, beam diagnostics, as well as veto signal generation for pixel detectors. Gotthard-II uses a…
▽ More
Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), energy dispersive experiments at 4.5 MHz frame rate, beam diagnostics, as well as veto signal generation for pixel detectors. Gotthard-II uses a silicon microstrip sensor with a pitch of 50 $μ$m or 25 $μ$m and with 1280 or 2560 channels wire-bonded to readout chips (ROCs). In the ROC, an adaptive gain switching pre-amplifier (PRE), a fully differential Correlated-Double-Sampling (CDS) stage, an Analog-to-Digital Converter (ADC) as well as a Static Random-Access Memory (SRAM) capable of storing all the 2700 images in an XFEL.EU bunch train will be implemented. Several prototypes with different designs of the analogue front-end (PRE and CDS) and ADC test structures have been fabricated in UMC-110 nm CMOS technology and their performance has been evaluated. In this paper, the performance of the analogue front-end and ADC will be summarized.
△ Less
Submitted 3 January, 2018; v1 submitted 23 November, 2017;
originally announced November 2017.
-
Towards Gotthard-II: Development of A Silicon Microstrip Detector for the European X-ray Free-Electron Laser
Authors:
Jiaguo Zhang,
Marie Andrä,
Rebecca Barten,
Anna Bergamaschi,
Martin Brückner,
Roberto Dinapoli,
Erik Froejdh,
Dominic Greiffenberg,
Carlos Lopez-Cuenca,
Davide Mezza,
Aldo Mozzanica,
Marco Ramilli,
Sophie Redford,
Marie Ruat,
Christian Ruder,
Bernd Schmitt,
Xintian Shi,
Dhanya Thattil,
Gemma Tinti,
Monica Turcato,
Seraphin Vettera
Abstract:
Gotthard-II is a 1-D microstrip detector specifically developed for the European X-ray Free-Electron Laser. It will not only be used in energy dispersive experiments but also as a beam diagnostic tool with additional logic to generate veto signals for the other 2-D detectors. Gotthard-II makes use of a silicon microstrip sensor with a pitch of either 50 μm or 25 μm and with 1280 or 2560 channels w…
▽ More
Gotthard-II is a 1-D microstrip detector specifically developed for the European X-ray Free-Electron Laser. It will not only be used in energy dispersive experiments but also as a beam diagnostic tool with additional logic to generate veto signals for the other 2-D detectors. Gotthard-II makes use of a silicon microstrip sensor with a pitch of either 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to adaptive gain switching readout chips. Built-in analog-to-digital converters and digital memories will be implemented in the readout chip for a continuous conversion and storage of frames for all bunches in the bunch train. The performance of analogue front-end prototypes of Gotthard has been investigated in this work. The results in terms of noise, conversionngain, dynamic range, obtained by means of infrared laser and X-rays, will be shown. In particular, the effects of the strip-to-strip coupling are studied in detail and it is found that the reduction of the coupling effects is one of the key factors for the development of the analogue front-end of Gotthard-II.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
-
Radiative transfer model for contaminated slabs : experimental validations
Authors:
François Andrieu,
Frédéric Schmidt,
Bernard Schmitt,
Sylvain Douté,
Olivier Brissaud
Abstract:
This article presents a set of spectro-goniometric measurements of different water ice samples and the comparison with an approximated radiative transfer model. The experiments were done using the spectro-radiogoniometer described in Brissaud et al. (2004). The radiative transfer model assumes an isotropization of the flux after the second interface and is fully described in Andrieu et al. (2015).…
▽ More
This article presents a set of spectro-goniometric measurements of different water ice samples and the comparison with an approximated radiative transfer model. The experiments were done using the spectro-radiogoniometer described in Brissaud et al. (2004). The radiative transfer model assumes an isotropization of the flux after the second interface and is fully described in Andrieu et al. (2015). Two kind of experiments were conducted. First, the specular spot was closely investigated, at high angular resolution, at the wavelength of $1.5\,\mbox{μm}$, where ice behaves as a very absorbing media. Second, the bidirectional reflectance was sampled at various geometries, including low phase angles on 61 wavelengths ranging from $0.8\,\mbox{μm}$ to $2.0\,\mbox{μm}$.
In order to validate the model, we made a qualitative test to demonstrate the relative isotropization of the flux. We also conducted quantitative assessments by using a bayesian inversion method in order to estimate the parameters (e.g. sample thickness, surface roughness) from the radiative measurements only. A simple comparison between the retrieved parameters and the direct independent measurements allowed us to validate the model.
We developed an innovative bayesian inversion approach to quantitatively estimate the uncertainties on the parameters avoiding the usual slow Monte Carlo approach. First we built lookup tables, and then searched the best fits and calculated a posteriori density probability functions. The results show that the model is able to reproduce the spectral behavior of water ice slabs, as well as the specular spot. In addition, the different parameters of the model are compatible with independent measurements.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Radiative transfer model for contaminated rough slabs
Authors:
François Andrieu,
Sylvain Douté,
Frédéric Schmidt,
Bernard Schmitt
Abstract:
We present a semi-analytical model to simulate bidirectional reflectance distribution function (BRDF) spectra of a rough slab layer containing impurities. This model has been optimized for fast computation in order to analyze hyperspectral data. We designed it for planetary surfaces ices studies but it could be used for other purposes. It estimates the bidirectional reflectance of a rough slab of…
▽ More
We present a semi-analytical model to simulate bidirectional reflectance distribution function (BRDF) spectra of a rough slab layer containing impurities. This model has been optimized for fast computation in order to analyze hyperspectral data. We designed it for planetary surfaces ices studies but it could be used for other purposes. It estimates the bidirectional reflectance of a rough slab of material containing inclusions, overlaying an optically thick media (semi-infinite media or stratified media, for instance granular material). The inclusions are supposed to be close to spherical, and of any type of other material than the ice matrix. It can be any type of other ice, mineral or even bubbles, defined by their optical constants. We suppose a low roughness and we consider the geometrical optics conditions. This model is thus applicable for inclusions larger than the considered wavelength. The scattering on the inclusions is assumed to be isotropic. This model has a fast computation implementation and thus is suitable for high resolution hyperspectral data analysis.
△ Less
Submitted 10 June, 2015;
originally announced June 2015.
-
Large-aperture wide-bandwidth antireflection-coated silicon lenses for millimeter wavelengths
Authors:
R. Datta,
C. D. Munson,
M. D. Niemack,
J. J. McMahon,
J. Britton,
E. J. Wollack,
J. Beall,
M. J. Devlin,
J. Fowler,
P. Gallardo,
J. Hubmayr,
K. Irwin,
L. Newburgh,
J. P. Nibarger,
L. Page,
M. A. Quijada,
B. L. Schmitt,
S. T. Staggs,
R. Thornton,
L. Zhang
Abstract:
The increasing scale of cryogenic detector arrays for sub-millimeter and millimeter wavelength astrophysics has led to the need for large aperture, high index of refraction, low loss, cryogenic refracting optics. Silicon with n = 3.4, low loss, and relatively high thermal conductivity is a nearly optimal material for these purposes, but requires an antireflection (AR) coating with broad bandwidth,…
▽ More
The increasing scale of cryogenic detector arrays for sub-millimeter and millimeter wavelength astrophysics has led to the need for large aperture, high index of refraction, low loss, cryogenic refracting optics. Silicon with n = 3.4, low loss, and relatively high thermal conductivity is a nearly optimal material for these purposes, but requires an antireflection (AR) coating with broad bandwidth, low loss, low reflectance, and a matched coefficient of thermal expansion. We present an AR coating for curved silicon optics comprised of subwavelength features cut into the lens surface with a custom three axis silicon dicing saw. These features constitute a metamaterial that behaves as a simple dielectric coating. We have fabricated and coated silicon lenses as large as 33.4 cm in diameter with coatings optimized for use between 125-165 GHz. Our design reduces average reflections to a few tenths of a percent for angles of incidence up to 30 degrees with low cross-polarization. We describe the design, tolerance, manufacture, and measurements of these coatings and present measurements of the optical properties of silicon at millimeter wavelengths at cryogenic and room temperatures. This coating and lens fabrication approach is applicable from centimeter to sub-millimeter wavelengths and can be used to fabricate coatings with greater than octave bandwidth.
△ Less
Submitted 17 July, 2013;
originally announced July 2013.
-
Challenges for the Adaptive Gain Integrating Pixel Detector (AGIPD) design due to the high intensity photon radiation environment at the European XFEL
Authors:
J. Becker,
L. Bianco,
P. Göttlicher,
H. Graafsma,
H. Hirsemann,
S. Jack,
A. Klyuev,
S. Lange A. Marras,
U. Trunk,
R. Klanner,
J. Schwandt,
J. Zhang,
R. Dinapoli,
D. Greiffenberg,
B. Henrich,
A. Mozzanica,
B. Schmitt,
X. Shi,
M. Gronewald,
H. Krüger
Abstract:
The European X-ray Free Electron Laser (XFEL) is a new research facility currently under construction in Hamburg, Germany. With a pulse length of less than 100 fs and an extremely high luminosity of 27000 flashes per second the European XFEL will have a unique time structure that demands the development of new detectors tailored to the requirements imposed by the experiments while complying with t…
▽ More
The European X-ray Free Electron Laser (XFEL) is a new research facility currently under construction in Hamburg, Germany. With a pulse length of less than 100 fs and an extremely high luminosity of 27000 flashes per second the European XFEL will have a unique time structure that demands the development of new detectors tailored to the requirements imposed by the experiments while complying with the machine specific operation parameters. The Adaptive Gain Integrating Pixel Detector (AGIPD) is one response to the need for large 2D detectors, able to cope with the 4.5 MHz frame rate, as well as with the high dynamic range needed by XFEL experiments ranging from single photons to more than 10$^4$ 12 keV photons per pixel per pulse. In addition it has to withstand doses of up to 1 GGy over three years.
△ Less
Submitted 11 March, 2013;
originally announced March 2013.
-
The single photon sensitivity of the Adaptive Gain Integrating Pixel Detector
Authors:
Julian Becker,
Dominic Greiffenberg,
Ulrich Trunk,
Xintian Shi,
Roberto Dinapoli,
Aldo Mozzanica,
Beat Henrich,
Bernd Schmitt,
Heinz Graafsma
Abstract:
Single photon sensitivity is an important property of certain detection systems. This work investigated the single photon sensitivity of the Adaptive Gain Integrating Pixel Detector (AGIPD) and its dependence on possible detector noise values. Due to special requirements at the European X-ray Free Electron Laser (XFEL) the AGIPD finds the number of photons absorbed in each pixel by integrating the…
▽ More
Single photon sensitivity is an important property of certain detection systems. This work investigated the single photon sensitivity of the Adaptive Gain Integrating Pixel Detector (AGIPD) and its dependence on possible detector noise values. Due to special requirements at the European X-ray Free Electron Laser (XFEL) the AGIPD finds the number of photons absorbed in each pixel by integrating the total signal. Photon counting is done off line on a thresholded data set.
It was shown that AGIPD will be sensitive to single photons of 8 keV energy or more (detection efficiency $\gg$ 50%, less than 1 count due to noise per 10$^6$ pixels). Should the final noise be at the lower end of the possible range (200 - 400 electrons) single photon sensitivity can also be achieved at 5 keV beam energy.
It was shown that charge summing schemes are beneficial when the noise is sufficiently low. The total detection rate of events is increased and the probability to count a single event multiple times in adjacent pixels is reduced by a factor of up to 40.
The entry window of AGIPD allows 3 keV photons to reach the sensitive volume with approximately 70% probability. Therefore the low energy performance of AGIPD was explored, finding a maximum noise floor below 0.035 hits/pixel/frame at 3 keV beam energy. Depending on the noise level and selected threshold this value can be reduced by a factor of approximately 10. Even though single photon sensitivity, as defined in this work, is not given, imaging at this energy is still possible, allowing Poisson noise limited performance for signals significantly above the noise floor.
△ Less
Submitted 23 July, 2012; v1 submitted 27 March, 2012;
originally announced March 2012.