-
Long-distance chronometric leveling with a transportable optical clock
Authors:
J. Grotti,
I. Nosske,
S. B. Koller,
S. Herbers,
H. Denker,
L. Timmen,
G. Vishnyakova,
G. Grosche,
T. Waterholter,
A. Kuhl,
S. Koke,
E. Benkler,
M. Giunta,
L. Maisenbacher,
A. Matveev,
S. Dörscher,
R. Schwarz,
A. Al-Masoudi,
T. W. Hänsch,
T. H. Udem,
R. Holzwarth,
C. Lisdat
Abstract:
We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotenti…
▽ More
We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of $3918.1(2.4)\,\mathrm{m^2 \, s^{-2}}$ agrees with an independent geodetic determination of $3915.88(0.30)\,\mathrm{m^2 \, s^{-2}}$. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of $24~\mathrm{cm}$ in height.
△ Less
Submitted 28 September, 2023; v1 submitted 26 September, 2023;
originally announced September 2023.
-
A low repetition rate optical frequency comb
Authors:
Francesco Canella,
Johannes Weitenberg,
Muhammad Thariq,
Fabian Schmid,
Paras Dwivedi,
Gianluca Galzerano,
Theodor W. Haensch,
Thomas Udem,
Akira Ozawa
Abstract:
Reducing the pulse repetition rate of an optical frequency comb increases the pulse energy for a given average power. This enhances the efficiency of nonlinear frequency conversion and it facilitates extending the accessible wavelength range, for example into the extreme ultraviolet (XUV). The resulting spectrally dense frequency comb can still be used for precision spectroscopy of narrow atomic o…
▽ More
Reducing the pulse repetition rate of an optical frequency comb increases the pulse energy for a given average power. This enhances the efficiency of nonlinear frequency conversion and it facilitates extending the accessible wavelength range, for example into the extreme ultraviolet (XUV). The resulting spectrally dense frequency comb can still be used for precision spectroscopy of narrow atomic or molecular transitions. In this article, we demonstrate a low-noise infrared frequency comb with a repetition rate as low as 40 kHz using a Yb:KYW mode-locked laser, pulse picking, and subsequent amplification. The frequency comb structure is confirmed by generating a beat note with a continuous wave reference laser. A comb mode is actively stabilized to the reference laser, and the integrated rms phase noise from 20 Hz to 20 kHz is measured to be 195 mrad.
△ Less
Submitted 18 September, 2023;
originally announced September 2023.
-
Number-Resolved Detection of Dark Ions in Coulomb Crystals
Authors:
Fabian Schmid,
Johannes Weitenberg,
Jorge Moreno,
Theodor W. Hänsch,
Thomas Udem,
Akira Ozawa
Abstract:
While it is straightforward to count laser-cooled trapped ions by fluorescence imaging, detecting the number of dark ions embedded and sympathetically cooled in a mixed ion crystal is more challenging. We demonstrate a method to track the number of dark ions in real time with single-particle sensitivity. This is achieved by observing discrete steps in the amount of fluorescence emitted from the co…
▽ More
While it is straightforward to count laser-cooled trapped ions by fluorescence imaging, detecting the number of dark ions embedded and sympathetically cooled in a mixed ion crystal is more challenging. We demonstrate a method to track the number of dark ions in real time with single-particle sensitivity. This is achieved by observing discrete steps in the amount of fluorescence emitted from the coolant ions while exciting secular motional resonances of dark ions. By counting the number of fluorescence steps, we can identify the number of dark ions without calibration and without relying on any physical model of the motional excitation. We demonstrate the scheme by detecting H$_2^+$ and H$_3^+$ ions embedded in a Be$^+$ ion Coulomb crystal in a linear radio frequency trap. Our method allows observing the generation and destruction of individual ions simultaneously for different types of ions. Besides high-resolution spectroscopy of dark ions, another application is the detection of chemical reactions in real time with single-particle sensitivity. This is demonstrated in this work.
△ Less
Submitted 5 October, 2022;
originally announced October 2022.
-
Motional resonances of three-dimensional dual-species Coulomb crystals
Authors:
Byoung-moo Ann,
Fabian Schmid,
Jonas Krause,
Theodor W. Hänsch,
Thomas Udem,
Akira Ozawa
Abstract:
We investigate the motional resonances of dual-species Coulomb crystals comprised of $^9$Be$^+$ and $^{24}$Mg$^+$ ions held in a 4-rod linear Paul trap. Our experimental data and simulations show that the secular motion of such mixed crystals has rich dynamics. Their secular spectra can differ significantly from those of pure ion crystals. We propose a simple model based on mechanical coupling wit…
▽ More
We investigate the motional resonances of dual-species Coulomb crystals comprised of $^9$Be$^+$ and $^{24}$Mg$^+$ ions held in a 4-rod linear Paul trap. Our experimental data and simulations show that the secular motion of such mixed crystals has rich dynamics. Their secular spectra can differ significantly from those of pure ion crystals. We propose a simple model based on mechanical coupling with Coulomb interactions between the two different ion species that explains many features of the secular spectrum. Our findings contribute to a more reliable identification of the ion species in mixed crystals.
△ Less
Submitted 15 February, 2021;
originally announced February 2021.
-
Simple phase noise measurement scheme for cavity-stabilized laser systems
Authors:
Fabian Schmid,
Johannes Weitenberg,
Theodor W. Hänsch,
Thomas Udem,
Akira Ozawa
Abstract:
We describe a simple method for measuring the residual fast phase noise of a cavity-stabilized laser using the cavity as a reference. The method is based on generating a beat note between the laser output and the strongly filtered light transmitted through the cavity. The beat note can be directly analyzed without requiring further calibration of system parameters. We apply the method to measure t…
▽ More
We describe a simple method for measuring the residual fast phase noise of a cavity-stabilized laser using the cavity as a reference. The method is based on generating a beat note between the laser output and the strongly filtered light transmitted through the cavity. The beat note can be directly analyzed without requiring further calibration of system parameters. We apply the method to measure the residual phase noise of an external-cavity diode laser (ECDL) locked to a reference cavity and compare the results with an analysis of the in-loop error signal of the feedback system.
△ Less
Submitted 15 February, 2021;
originally announced February 2021.
-
Deuteron charge radius and Rydberg constant from spectroscopy data in atomic deuterium
Authors:
Randolf Pohl,
François Nez,
Thomas Udem,
Aldo Antognini,
Axel Beyer,
Hélène Fleurbaey,
Alexey Grinin,
Theodor W. Hänsch,
Lucile Julien,
Franz Kottmann,
Julian J. Krauth,
Lothar Maisenbacher,
Arthur Matveev,
François Biraben
Abstract:
We give a pedagogical description of the method to extract the charge radii and Rydberg constant from laser spectroscopy in regular hydrogen (H) and deuterium (D) atoms, that is part of the CODATA least-squares adjustment (LSA) of the fundamental physical constants. We give a deuteron charge radius Rd from D spectroscopy alone of 2.1415(45) fm. This value is independent of the measurements that le…
▽ More
We give a pedagogical description of the method to extract the charge radii and Rydberg constant from laser spectroscopy in regular hydrogen (H) and deuterium (D) atoms, that is part of the CODATA least-squares adjustment (LSA) of the fundamental physical constants. We give a deuteron charge radius Rd from D spectroscopy alone of 2.1415(45) fm. This value is independent of the measurements that lead to the proton charge radius, and five times more accurate than the value found in the CODATA Adjustment 10. The improvement is due to the use of a value for the 1S->2S transition in atomic deuterium which can be inferred from published data or found in a PhD thesis.
△ Less
Submitted 23 November, 2016; v1 submitted 11 July, 2016;
originally announced July 2016.
-
Real-time dual frequency comb spectroscopy in the near infrared
Authors:
Feng Zhu,
Tarek Mohamed,
James Strohaber,
Alexandre A. Kolomenskii,
Thomas Udem,
Hans A. Schuessler
Abstract:
We use two femtosecond Erbium-doped fiber lasers with slightly different repetition rates to perform a modern type of Fourier transform spectroscopy without moving parts. The measurements are done in real time, and it takes less than 50 microseconds. We work with somewhat different spectral outputs from two Erbium-doped fiber lasers and employ spectral filtering based on a 2f-2f grating setup to s…
▽ More
We use two femtosecond Erbium-doped fiber lasers with slightly different repetition rates to perform a modern type of Fourier transform spectroscopy without moving parts. The measurements are done in real time, and it takes less than 50 microseconds. We work with somewhat different spectral outputs from two Erbium-doped fiber lasers and employ spectral filtering based on a 2f-2f grating setup to select the common spectral region of interest, thereby increasing the signal-to-noise ratio. The interferogram is taken with a 20 cm long gas cell, containing a mixture of acetylene and air at atmospheric pressure, and is fast-Fourier-transformed to obtain the broadband spectral fingerprint of the gas.
△ Less
Submitted 23 August, 2012;
originally announced August 2012.
-
Sub-milliKelvin spatial thermometry of a single Doppler cooled ion in a Paul trap
Authors:
S. Knünz,
M. Herrmann,
V. Batteiger,
G. Saathoff,
T. W. Hänsch,
Th. Udem
Abstract:
We report on observations of thermal motion of a single, Doppler-cooled ion along the axis of a linear radio-frequency quadrupole trap. We show that for a harmonic potential the thermal occupation of energy levels leads to Gaussian distribution of the ion's axial position. The dependence of the spatial thermal spread on the trap potential is used for precise calibration of our imaging system's poi…
▽ More
We report on observations of thermal motion of a single, Doppler-cooled ion along the axis of a linear radio-frequency quadrupole trap. We show that for a harmonic potential the thermal occupation of energy levels leads to Gaussian distribution of the ion's axial position. The dependence of the spatial thermal spread on the trap potential is used for precise calibration of our imaging system's point spread function and sub-milliKelvin thermometry. We employ this technique to investigate the laser detuning dependence of the Doppler temperature.
△ Less
Submitted 1 March, 2012;
originally announced March 2012.
-
Improved Measurement of the Hydrogen 1S - 2S Transition Frequency
Authors:
Christian G. Parthey,
Arthur Matveev,
Janis Alnis,
Birgitta Bernhardt,
Axel Beyer,
Ronald Holzwarth,
Aliaksei Maistrou,
Randolf Pohl,
Katharina Predehl,
Thomas Udem,
Tobias Wilken,
Nikolai Kolachevsky,
Michel Abgrall,
Daniele Rovera,
Christophe Salomon,
Philippe Laurent,
Theodor W. Hänsch
Abstract:
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency uncertainty of $4.2\times 10^{-15}$ improving the previous measure- ment by our own group [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)] by a factor of 3.3.…
▽ More
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency uncertainty of $4.2\times 10^{-15}$ improving the previous measure- ment by our own group [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)] by a factor of 3.3. The probe laser frequency was phase coherently linked to the mobile cesium fountain clock FOM via a frequency comb.
△ Less
Submitted 15 July, 2011;
originally announced July 2011.
-
Comment on "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions"
Authors:
G. Saathoff,
S. Reinhardt,
R. Holzwarth,
T. W. Hänsch,
Th. Udem,
D. Bing,
D. Schwalm,
A. Wolf,
S. Karpuk,
G. Huber,
C. Novotny,
B. Botermann,
C. Geppert,
W. Nörtershäuser,
T. Kühl,
T. Stöhlker,
G. Gwinner
Abstract:
In an article "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions" by S. Devasia [arXiv:1003.2970v1], our recent Doppler shift experiments on fast ion beams are reanalyzed. Contrary to our analysis, Devasia concludes that our results provide an "indication of Lorentz violation". We argue that this conclusion is based on a fundamental misunderstanding of our experim…
▽ More
In an article "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions" by S. Devasia [arXiv:1003.2970v1], our recent Doppler shift experiments on fast ion beams are reanalyzed. Contrary to our analysis, Devasia concludes that our results provide an "indication of Lorentz violation". We argue that this conclusion is based on a fundamental misunderstanding of our experimental scheme and reiterate that our results are in excellent agreement with Special Relativity.
△ Less
Submitted 28 February, 2011;
originally announced February 2011.
-
Cavity-enhanced dual-comb spectroscopy
Authors:
Birgitta Bernhardt,
Akira Ozawa,
Patrick Jacquet,
Marion Jacquey,
Yohei Kobayashi,
Thomas Udem,
Ronald Holzwarth,
Guy Guelachvili,
Theodor W. Hänsch,
Nathalie Picqué
Abstract:
The sensitivity of molecular fingerprinting is dramatically improved when placing the absorbing sample in a high-finesse optical cavity, thanks to the large increase of the effective path-length. As demonstrated recently, when the equidistant lines from a laser frequency comb are simultaneously injected into the cavity over a large spectral range, multiple trace-gases may be identified within a…
▽ More
The sensitivity of molecular fingerprinting is dramatically improved when placing the absorbing sample in a high-finesse optical cavity, thanks to the large increase of the effective path-length. As demonstrated recently, when the equidistant lines from a laser frequency comb are simultaneously injected into the cavity over a large spectral range, multiple trace-gases may be identified within a few milliseconds. Analyzing efficiently the light transmitted through the cavity however still remains challenging. Here, a novel approach, cavity-enhanced frequency comb Fourier transform spectroscopy, fully overcomes this difficulty and measures ultrasensitive, broad-bandwidth, high-resolution spectra within a few tens of $μ$s. It could be implemented from the Terahertz to the ultraviolet regions without any need for detector arrays. We recorded, within 18 $μ$s, spectra of the 1.0 $μ$m overtone bands of ammonia spanning 20 nm with 4.5 GHz resolution and a noise-equivalent-absorption at one-second-averaging per spectral element of 3 10^-12 cm^-1Hz^-1/2, thus opening a route to time-resolved spectroscopy of rapidly-evolving single-events.
△ Less
Submitted 13 August, 2009;
originally announced August 2009.
-
Precision spectroscopy of the 3s-3p fine structure doublet in Mg+
Authors:
V. Batteiger,
S. Knünz,
M. Herrmann,
G. Saathoff,
H. A. Schüssler,
B. Bernhardt,
T. Wilken,
R. Holzwarth,
T. W. Hänsch,
Th. Udem
Abstract:
We apply a recently demonstrated method for precision spectroscopy on strong transitions in trapped ions to measure both fine structure components of the 3s-3p transition in 24-Mg+ and 26-Mg+. We deduce absolute frequency reference data for transition frequencies, isotope shifts and fine structure splittings that are in particular useful for comparison with quasar absorption spectra, which test…
▽ More
We apply a recently demonstrated method for precision spectroscopy on strong transitions in trapped ions to measure both fine structure components of the 3s-3p transition in 24-Mg+ and 26-Mg+. We deduce absolute frequency reference data for transition frequencies, isotope shifts and fine structure splittings that are in particular useful for comparison with quasar absorption spectra, which test possible space-time variations of the fine structure constant. The measurement accuracy improves previous literature values, when existing, by more than two orders of magnitude.
△ Less
Submitted 2 July, 2009;
originally announced July 2009.
-
Frequency Metrology on single trapped ions in the weak binding limit: The 3s1/2-3p3/2 transition in 24-Mg+
Authors:
M. Herrmann,
V. Batteiger,
S. Knünz,
G. Saathoff,
Th. Udem,
T. W. Hänsch
Abstract:
We demonstrate a method for precision spectroscopy on trapped ions in the limit of unresolved motional sidebands. By sympathetic cooling of a chain of crystallized ions we suppress adverse temperature variations induced by the spectroscopy laser that usually lead to a distorted line profle and obtain a Voigt profile with negligible distortions. We applied the method to measure the absolute frequ…
▽ More
We demonstrate a method for precision spectroscopy on trapped ions in the limit of unresolved motional sidebands. By sympathetic cooling of a chain of crystallized ions we suppress adverse temperature variations induced by the spectroscopy laser that usually lead to a distorted line profle and obtain a Voigt profile with negligible distortions. We applied the method to measure the absolute frequency of the astrophysically relevant D2 transition in single 24-Mg+ ions and find 1072082934.33(16)MHz, a nearly 400fold improvement over previous results. Further, we find the excited state lifetime to be 3.84(10) ns.
△ Less
Submitted 16 January, 2009; v1 submitted 29 August, 2008;
originally announced August 2008.
-
Sub-Hz line width diode lasers by stabilization to vibrationally and thermally compensated ULE Fabry-Perot cavities
Authors:
J. Alnis,
A. Matveev,
N. Kolachevsky,
T. Wilken,
Th. Udem,
T. W. Haensch
Abstract:
We achieved a 0.5 Hz optical beat note line width with ~ 0.1 Hz/s frequency drift at 972 nm between two external cavity diode lasers independently stabilized to two vertically mounted Fabry-Perot (FP) reference cavities. Vertical FP reference cavities are suspended in mid-plane such that the influence of vertical vibrations to the mirror separation is significantly suppressed. This makes the set…
▽ More
We achieved a 0.5 Hz optical beat note line width with ~ 0.1 Hz/s frequency drift at 972 nm between two external cavity diode lasers independently stabilized to two vertically mounted Fabry-Perot (FP) reference cavities. Vertical FP reference cavities are suspended in mid-plane such that the influence of vertical vibrations to the mirror separation is significantly suppressed. This makes the setup virtually immune for vertical vibrations that are more difficult to isolate than the horizontal vibrations. To compensate for thermal drifts the FP spacers are made from Ultra-Low-Expansion (ULE) glass which possesses a zero linear expansion coefficient. A new design using Peltier elements in vacuum allows operation at an optimal temperature where the quadratic temperature expansion of the ULE could be eliminated as well. The measured linear drift of such ULE FP cavity of 63 mHz/s was due to material aging and the residual frequency fluctuations were less than 40 Hz during 16 hours of measurement. Some part of the temperature-caused drift is attributed to the thermal expansion of the mirror coatings. High-frequency thermal fluctuations that cause vibrations of the mirror surfaces limit the stability of a well designed reference cavity. By comparing two similar laser systems we obtain an Allan instability of 2*10-15 between 0.1 and 10 s averaging time, which is close to the theoretical thermal noise limit.
△ Less
Submitted 28 January, 2008;
originally announced January 2008.
-
Cavity Enhanced Optical Vernier Spectroscopy, Broad Band, High Resolution, High Sensitivity
Authors:
Christoph Gohle,
Björn Stein,
Albert Schliesser,
Thomas Udem,
Theodor W. Hänsch
Abstract:
A femtosecond frequency comb provides a vast number of equidistantly spaced narrow band laser modes that can be simultaneously tuned and frequency calibrated with 15 digits accuracy. Our Vernier spectrometer utilizes all of theses modes in a massively parallel manner to rapidly record both absorption and dispersion spectra with a sensitivity that is provided by a high finesse broad band optical…
▽ More
A femtosecond frequency comb provides a vast number of equidistantly spaced narrow band laser modes that can be simultaneously tuned and frequency calibrated with 15 digits accuracy. Our Vernier spectrometer utilizes all of theses modes in a massively parallel manner to rapidly record both absorption and dispersion spectra with a sensitivity that is provided by a high finesse broad band optical resonator and a resolution that is only limited by the frequency comb line width while keeping the required setup simple.
△ Less
Submitted 11 June, 2007;
originally announced June 2007.
-
High-precision wavelength calibration of astronomical spectrographs with laser frequency combs
Authors:
M. T. Murphy,
Th. Udem,
R. Holzwarth,
A. Sizmann,
L. Pasquini,
C. Araujo-Hauck,
H. Dekker,
S. D'Odorico,
M. Fischer,
T. W. Hänsch,
A. Manescau
Abstract:
We describe a possible new technique for precise wavelength calibration of high-resolution astronomical spectrographs using femtosecond-pulsed mode-locked lasers controlled by stable oscillators such as atomic clocks. Such `frequency combs' provide a series of narrow modes which are uniformly spaced according to the laser's pulse repetition rate and whose absolute frequencies are known a priori…
▽ More
We describe a possible new technique for precise wavelength calibration of high-resolution astronomical spectrographs using femtosecond-pulsed mode-locked lasers controlled by stable oscillators such as atomic clocks. Such `frequency combs' provide a series of narrow modes which are uniformly spaced according to the laser's pulse repetition rate and whose absolute frequencies are known a priori with relative precision better than 10^{-12}. Simulations of frequency comb spectra show that the photon-limited wavelength calibration precision achievable with existing echelle spectrographs should be ~1 cm/s when integrated over a 4000A range. Moreover, comb spectra may be used to accurately characterise distortions of the wavelength scale introduced by the spectrograph and detector system. The simulations show that frequency combs with pulse repetition rates of 5-30GHz are required, given the typical resolving power of existing and possible future echelle spectrographs. Achieving such high repetition rates, together with the desire to produce all comb modes with uniform intensity over the entire optical range, represent the only significant challenges in the design of a practical system. Frequency comb systems may remove wavelength calibration uncertainties from all practical spectroscopic experiments, even those combining data from different telescopes over many decades.
△ Less
Submitted 28 June, 2007; v1 submitted 23 March, 2007;
originally announced March 2007.
-
New Limits to the Drift of Fundamental Constants from Laboratory Measurements
Authors:
M. Fischer,
N. Kolachevsky,
M. Zimmermann,
R. Holzwarth,
Th. Udem,
T. W. Haensch,
M. Abgrall,
J. Gruenert,
I. Maksimovic,
S. Bize,
H. Marion,
F. Pereira Dos Santos,
P. Lemonde,
G. Santarelli,
P. Laurent,
A. Clairon,
C. Salomon,
M. Haas,
U. D. Jentschura,
C. H. Keitel
Abstract:
We have remeasured the absolute $1S$-$2S$ transition frequency $ν_{\rm {H}}$ in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of $(-29\pm 57)$ Hz for the drift of $ν_{\rm {H}}$ with respect to the ground state hyperfine splitting $ν_{\rm {Cs}}$ in $^{133}$Cs. Combining this result with the recently published optical transition frequency…
▽ More
We have remeasured the absolute $1S$-$2S$ transition frequency $ν_{\rm {H}}$ in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of $(-29\pm 57)$ Hz for the drift of $ν_{\rm {H}}$ with respect to the ground state hyperfine splitting $ν_{\rm {Cs}}$ in $^{133}$Cs. Combining this result with the recently published optical transition frequency in $^{199}$Hg$^+$ against $ν_{\rm {Cs}}$ and a microwave $^{87}$Rb and $^{133}$Cs clock comparison, we deduce separate limits on $\dotα/α= (-0.9\pm 2.9)\times 10^{-15}$ yr$^{-1}$ and the fractional time variation of the ratio of Rb and Cs nuclear magnetic moments $μ_{\rm {Rb}}/μ_{\rm {Cs}}$ equal to $(-0.5 \pm 1.7)\times 10^{-15}$ yr$^{-1}$. The latter provides information on the temporal behavior of the constant of strong interaction.
△ Less
Submitted 4 June, 2004; v1 submitted 12 December, 2003;
originally announced December 2003.
-
Precision Spectroscopy of Atomic Hydrogen and Variations of Fundamental Constants
Authors:
M. Fischer,
N. Kolachevsky,
M. Zimmermann,
R. Holzwarth,
Th. Udem,
T. W. Hänsch,
M. Abgrall,
J. Grünert,
I. Maksimovic,
S. Bize,
H. Marion,
F. Pereira Dos Santos,
P. Lemonde,
G. Santarelli,
P. Laurent,
A. Clairon,
C. Salomon
Abstract:
In 2003 we have measured the absolute frequency of the $(1S, F=1, m_F=\pm 1) \leftrightarrow (2S, F'=1, m_F'=\pm 1)$ two-photon transition in atomic hydrogen. We observed a variation of $(-29\pm 57)$ Hz over a 44 months interval separating this measurement from the previous one performed in 1999. We have combined this result with recently published results of optical transition frequency measure…
▽ More
In 2003 we have measured the absolute frequency of the $(1S, F=1, m_F=\pm 1) \leftrightarrow (2S, F'=1, m_F'=\pm 1)$ two-photon transition in atomic hydrogen. We observed a variation of $(-29\pm 57)$ Hz over a 44 months interval separating this measurement from the previous one performed in 1999. We have combined this result with recently published results of optical transition frequency measurement in the $^{199}$Hg$^+$ ion and and comparison between clocks based on $^{87}$Rb and $^{133}$Cs. From this combination we deduce the stringent limits for fractional time variation of the fine structure constant $\partial/{\partial t}(\ln α)=(-0.9\pm 4.2)\times 10^{-15}$ yr$^{-1}$ and for the ratio of $^{87}$Rb and $^{133}$Cs spin magnetic moments $\partial/{\partial t}(\ln[μ_{\rm {Rb}}/μ_{\rm {Cs}}])=(0.5\pm 2.1)\times 10^{-15}$ yr$^{-1}$. This is the first precise restriction for the fractional time variation of $α$ made without assumptions about the relative drifts of the constants of electromagnetic, strong and weak interactions.
△ Less
Submitted 27 July, 2004; v1 submitted 26 November, 2003;
originally announced November 2003.
-
Absolute Frequency Measurements of the Hg^+ and Ca Optical Clock Transitions with a Femtosecond Laser
Authors:
Th. Udem,
S. A. Diddams,
K. R. Vogel,
C. W. Oates,
E. A. Curtis,
W. D. Lee,
W. M. Itano,
R. E. Drullinger,
J. C. Bergquist,
L. Hollberg
Abstract:
The frequency comb created by a femtosecond mode-locked laser and a microstructured fiber is used to phase coherently measure the frequencies of both the Hg^+ and Ca optical standards with respect to the SI second as realized at NIST. We find the transition frequencies to be f_Hg=1 064 721 609 899 143(10) Hz and f_Ca=455 986 240 494 158(26) Hz, respectively. In addition to the unprecedented prec…
▽ More
The frequency comb created by a femtosecond mode-locked laser and a microstructured fiber is used to phase coherently measure the frequencies of both the Hg^+ and Ca optical standards with respect to the SI second as realized at NIST. We find the transition frequencies to be f_Hg=1 064 721 609 899 143(10) Hz and f_Ca=455 986 240 494 158(26) Hz, respectively. In addition to the unprecedented precision demonstrated here, this work is the precursor to all-optical atomic clocks based on the Hg^+ and Ca standards. Furthermore, when combined with previous measurements, we find no time variations of these atomic frequencies within the uncertainties of |(df_Ca/dt)/f_Ca| < 8 x 10^{-14} yr^{-1}, and |(df_Hg/dt)/f_Hg|< 30 x 10^{-14} yr^{-1}.
△ Less
Submitted 4 January, 2001;
originally announced January 2001.