Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content
The total reactive phosphorus (TRP) and nitrate concentrations of the River Enborne, southern England, were monitored at hourly interval between January 2010 and December 2011. The relationships between these high-frequency nutrient... more
The total reactive phosphorus (TRP) and nitrate concentrations of the River Enborne, southern England, were monitored at hourly interval between January 2010 and December 2011. The relationships between these high-frequency nutrient concentration signals and flow were used to infer changes in nutrient source and dynamics through the annual cycle and each individual storm event, by studying hysteresis patterns. TRP concentrations exhibited strong dilution patterns with increasing flow, and predominantly clockwise hysteresis through storm events. Despite the Enborne catchment being relatively rural for southern England, TRP inputs were dominated by constant, non-rain-related inputs from sewage treatment works (STW) for the majority of the year, producing the highest phosphorus concentrations through the spring-summer growing season. At higher river flows, the majority of the TRP load was derived from within-channel remobilisation of phosphorus from the bed sediment, much of which was ...
The EU Water Framework Directive (WFD) requires that the ecological and chemical status of water bodies in Europe should be assessed, and action taken where possible to ensure that at least "good" quality is attained in... more
The EU Water Framework Directive (WFD) requires that the ecological and chemical status of water bodies in Europe should be assessed, and action taken where possible to ensure that at least "good" quality is attained in each case by 2015. This paper is concerned with the accuracy and precision with which chemical status in rivers can be measured given certain sampling strategies, and how this can be improved. High frequency (hourly) chemical data from four rivers in southern England were subsampled to simulate different sampling strategies for four parameters used for WFD classification: dissolved phosphorus, dissolved oxygen, pH and water temperature. These data sub-sets were then used to calculate the WFD classification for each site. Monthly sampling was less precise than weekly sampling, but the effect on WFD classification depended on the closeness of the range of concentrations to the class boundaries. In some cases, monthly sampling for a year could result in the same water body being assigned to one of 3 or 4 WFD classes with 95% confidence, whereas with weekly sampling this was 1 or 2 classes for the same cases. In the most extreme case, random sampling effects could result in the same water body being assigned to any of the 5 WFD quality classes. The width of the weekly sampled confidence intervals was about 33% that of the monthly for P species and pH, about 50% for dissolved oxygen, and about 67% for water temperature. For water temperature, which is assessed as the 98th percentile in the UK, monthly sampling biases the mean downwards by about 1 °C compared to the true value, due to problems of assessing high percentiles with limited data. Confining sampling to the working week compared to all seven days made little difference, but a modest improvement in precision could be obtained by sampling at the same time of day within a 3 h time window, and this is recommended. For parameters with a strong diel variation, such as dissolved oxygen, the value obtained, and thus possibly the WFD classification, can depend markedly on when in the cycle the sample was taken. Specifying this in the sampling regime would be a straightforward way to improve precision, but there needs to be agreement about how best to characterise risk in different types of river. These results suggest that in some cases it will be difficult to assign accurate WFD chemical classes or to detect likely trends using current sampling regimes, even for these largely groundwater-fed rivers. A more critical approach to sampling is needed to ensure that management actions are appropriate and supported by data.
Research Interests:
Research Interests:
Research Interests:
ABSTRACT Mechanistic catchment-scale phosphorus models appear to perform poorly where diffuse sources dominate. We investigate the reasons for this for one model, INCA-P, testing model output against 18 months of daily data in a small... more
ABSTRACT Mechanistic catchment-scale phosphorus models appear to perform poorly where diffuse sources dominate. We investigate the reasons for this for one model, INCA-P, testing model output against 18 months of daily data in a small Scottish catchment. We examine key model processes and provide recommendations for model improvement and simplification. Improvements to the particulate phosphorus simulation are especially needed. The model evaluation procedure is then generalised to provide a checklist for identifying why model performance may be poor or unreliable, incorporating calibration, data, structural and conceptual challenges. There needs to be greater recognition that current models struggle to produce positive Nash–Sutcliffe statistics in agricultural catchments when evaluated against daily data. Phosphorus modelling is difficult, but models are not as useless as this might suggest. We found a combination of correlation coefficients, bias, a comparison of distributions and a visual assessment of time series a better means of identifying realistic simulations.
This paper describes the hydrochemistry of a lowland, urbanised river-system, The Cut in England, using in situ sub-daily sampling. The Cut receives effluent discharges from four major sewage treatment works serving around 190,000 people.... more
This paper describes the hydrochemistry of a lowland, urbanised river-system, The Cut in England, using in situ sub-daily sampling. The Cut receives effluent discharges from four major sewage treatment works serving around 190,000 people. These discharges consist largely of treated water, originally abstracted from the River Thames and returned via the water supply network, substantially increasing the natural flow. The hourly water quality data were supplemented by weekly manual sampling with laboratory analysis to check the hourly data and measure further determinands. Mean phosphorus and nitrate concentrations were very high, breaching standards set by EU legislation. Though 56% of the catchment area is agricultural, the hydrochemical dynamics were significantly impacted by effluent discharges which accounted for approximately 50% of the annual P catchment input loads and, on average, 59% of river flow at the monitoring point. Diurnal dissolved oxygen data demonstrated high in-stream productivity. From a comparison of high frequency and conventional monitoring data, it is inferred that much of the primary production was dominated by benthic algae, largely diatoms. Despite the high productivity and nutrient concentrations, the river water did not become anoxic and major phytoplankton blooms were not observed. The strong diurnal and annual variation observed showed that assessments of water quality made under the Water Framework Directive (WFD) are sensitive to the time and season of sampling. It is recommended that specific sampling time windows be specified for each determinand, and that WFD targets should be applied in combination to help identify periods of greatest ecological risk.
ABSTRACT Recently there have been advances in automatic monitoring systems for water quality linked to environmental modeling. The difficulty of performing such sensing in natural environments leads to a high probability of faults and... more
ABSTRACT Recently there have been advances in automatic monitoring systems for water quality linked to environmental modeling. The difficulty of performing such sensing in natural environments leads to a high probability of faults and demands for high density data make automated self-test an important requirement. As part of an evaluation of failures in Lab-on-Chip (LOC) Ion Chromatography (IC) and Capillary Electrophoresis (CE) based systems, we passed river water through LOC devices for long periods showing that such system are feasible, but illustrating that failures are likely. Conductivity is the preferred method of detection for IC and CE, but a problem with all such detectors is the need to suppress background conductivity. Chemical suppression is often utilized, but in-situ systems can be simplified using electronic methods. We have developed an approach which directly suppresses baseline current. Detection signals and baseline profiles can be used to diagnose faults, typically manually by an experienced technician. In this paper we discuss automated test strategies for in-situ monitors at both the sensor network and individual instrument level. We also report preliminary investigations into development of automated fault detection using baseline and detection signals.
This paper examines two hydrochemical time-series derived from stream samples taken in the Upper Hafren catchment, Plynlimon, Wales. One time-series comprises data collected at 7-hour intervals over 22 months (Neal et al., 2012-this... more
This paper examines two hydrochemical time-series derived from stream samples taken in the Upper Hafren catchment, Plynlimon, Wales. One time-series comprises data collected at 7-hour intervals over 22 months (Neal et al., 2012-this issue), while the other is based on weekly sampling over 20 years. A subset of determinands: aluminium, calcium, chloride, conductivity, dissolved organic carbon, iron, nitrate, pH, silicon and sulphate are examined within a framework of non-stationary time-series analysis to identify determinand trends, seasonality and short-term dynamics. The results demonstrate that both long-term and high-frequency monitoring provide valuable and unique insights into the hydrochemistry of a catchment. The long-term data allowed analysis of long-term trends, demonstrating continued increases in DOC concentrations accompanied by declining SO(4) concentrations within the stream, and provided new insights into the changing amplitude and phase of the seasonality of the determinands such as DOC and Al. Additionally, these data proved invaluable for placing the short-term variability demonstrated within the high-frequency data within context. The 7-hour data highlighted complex diurnal cycles for NO(3), Ca and Fe with cycles displaying changes in phase and amplitude on a seasonal basis. The high-frequency data also demonstrated the need to consider the impact that the time of sample collection can have on the summary statistics of the data and also that sampling during the hours of darkness provides additional hydrochemical information for determinands which exhibit pronounced diurnal variability. Moving forward, this research demonstrates the need for both long-term and high-frequency monitoring to facilitate a full and accurate understanding of catchment hydrochemical dynamics.

And 4 more