Traditionally, conductive materials for electrodes are based on high modulus metals or alloys. Development of bioelectrodes that mimic the mechanical properties of the soft, low modulus tissues in which they are implanted is a rapidly... more
Traditionally, conductive materials for electrodes are based on high modulus metals or alloys. Development of bioelectrodes that mimic the mechanical properties of the soft, low modulus tissues in which they are implanted is a rapidly expanding field of research. Many polymers exist that more closely match tissue mechanics than metals; however, the majority do not conduct charge. Integrating conductive properties via incorporation of metals and other conductors into nonconductive polymers is a successful approach to producing polymers that can be used in electrical interfacing devices. When combining conductive materials with nonconductive polymer matrices, there is often a tradeoff between the electrical and mechanical properties. This review analyzes the advantages and disadvantages of approaches involving coating or layer formation, composite formation via dispersion of conductive inclusions through polymer matrices, and in situ growth of a conductive network within polymers.
Hydrogels hold significant promise for supporting cell based therapies in the field of bioelectrodes. It has been proposed that tissue engineering principles can be used to improve the integration of neural interfacing electrodes.... more
Hydrogels hold significant promise for supporting cell based therapies in the field of bioelectrodes. It has been proposed that tissue engineering principles can be used to improve the integration of neural interfacing electrodes. Degradable hydrogels based on poly (vinyl alcohol) functionalised with tyramine (PVA-Tyr) have been shown to support covalent incorporation of non-modified tyrosine rich proteins within synthetic hydrogels. PVA-Tyr crosslinked with such proteins, were explored as a scaffold for supporting development of neural tissue in a three dimensional (3D) environment. In this study a model neural cell line (PC12) and glial accessory cell line, Schwann cell (SC) were encapsulated in PVA-Tyr crosslinked with gelatin and sericin. Specifically, this study aimed to examine the growth and function of SC and PC12 co-cultures when translated from a two dimensional (2D) environment to a 3D environment. PC12 differentiation was successfully promoted in both 2D and 3D at 25 days post-culture. SC encapsulated as a single cell line and in co-culture were able to produce both laminin and collagen-IV which are required to support neuronal development. Neurite outgrowth in the 3D environment was confirmed by immunocytochemical staining. PVA-Tyr/sericin/gelatin hydrogel showed mechanical properties similar to nerve tissue elastic modulus. It is suggested that the mechanical properties of the PVA-Tyr hydrogels with native protein components are providing with a compliant substrate that can be used to support the survival and differentiation of neural networks.
Neural-interfacing devices are an artificial mechanism for restoring or supplementing the function of the nervous system, lost as a result of injury or disease. Conducting polymers (CPs) are gaining significant attention due to their... more
Neural-interfacing devices are an artificial mechanism for restoring or supplementing the function of the nervous system, lost as a result of injury or disease. Conducting polymers (CPs) are gaining significant attention due to their capacity to meet the performance criteria of a number of neuronal therapies including recording and stimulating neural activity, the regeneration of neural tissue and the delivery of bioactive molecules for mediating device-tissue interactions. CPs form a flexible platform technology that enables the development of tailored materials for a range of neuronal diagnostic and treatment therapies. In this review, the application of CPs for neural prostheses and other neural interfacing devices is discussed, with a specific focus on neural recording, neural stimulation, neural regeneration, and therapeutic drug delivery.
Mechanical discrepancies between conventional platinum (Pt) electrodes and neural tissue often result in scar tissue encapsulation of implanted neural recording and stimulating devices. Olfactory ensheathing cells (OECs) are a supportive... more
Mechanical discrepancies between conventional platinum (Pt) electrodes and neural tissue often result in scar tissue encapsulation of implanted neural recording and stimulating devices. Olfactory ensheathing cells (OECs) are a supportive glial cell in the olfactory nervous system which can transition through glial scar tissue while supporting the outgrowth of neural processes. It has been proposed that this function can be used to reconnect implanted electrodes with the target neural pathways. Conductive hydrogel (CH) electrode coatings have been proposed as a substrate for supporting OEC survival and proliferation at the device interface. To determine an ideal CH to support OECs, this study explored eight CH variants, with differing biochemical composition, in comparison to a conventional Pt electrodes. All CH variants were based on a biosynthetic hydrogel, consisting of poly(vinyl alcohol) and heparin, through which the conductive polymer (CP) poly(3,4-ethylenedioxythiophene) was electropolymerized. The biochemical composition was varied through incorporation of gelatin and sericin, which were expected to provide cell adherence functionality, supporting attachment, and cell spreading. Combinations of these biomolecules varied from 1 to 3 wt %. The physical, electrical, and biological impact of these molecules on electrode performance was assessed. Cyclic voltammetry and electrochemical impedance spectroscopy demonstrated that the addition of these biological molecules had little significant effect on the coating's ability to safely transfer charge. Cell attachment studies, however, determined that the incorporation of 1 wt % gelatin in the hydrogel was sufficient to significantly increase the attachment of OECs compared to the nonfunctionalized CH. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2015.
Photo-polymerizable hydrogels have been widely researched as tissue engineering matrices. When designing a new photo-crosslinkable, biosynthetic hydrogel system, a number of parameters need to be optimized, such as the polymerization... more
Photo-polymerizable hydrogels have been widely researched as tissue engineering matrices. When designing a new photo-crosslinkable, biosynthetic hydrogel system, a number of parameters need to be optimized, such as the polymerization conditions and amount of biological polymer included. This study aimed to investigate the crosslinking parameters (i.e., choice of initiator, light intensity and irradiation time), as well as the biological polymer (i.e., gelatin) content , for a degradable tyramine functionalized poly(vinyl alcohol) (PVA-Tyr) system. This PVA-Tyr can be photocrosslinked using a visible light initiated process composed of ruthenium (Ru) and persulfate compounds. Comparison of ammonium persulfate (APS) and sodium persulfate (SPS) showed that SPS supported fabrication of higher quality gels at lower concentrations than APS. The initiator concentration and irradiation conditions that were found to produce the best quality PVA-Tyr gels were 2 mM Ru/20 mM SPS and 3 minutes o...
ABSTRACT
ABSTRACT Biological responses to neural interfacing electrodes can be modulated via biofunctionalisation of conducting polymer (CP) coatings. This study investigated the use of small bioactive molecules with anti-inflammatory properties.... more
ABSTRACT Biological responses to neural interfacing electrodes can be modulated via biofunctionalisation of conducting polymer (CP) coatings. This study investigated the use of small bioactive molecules with anti-inflammatory properties. Specifically, anionic dexamethasone phosphate (DP) and valproic acid (VA) were used to dope the CP poly(ethylenedioxythiophene) (PEDOT). The impact of DP and VA on material properties was explored both individually and together as a codoped system, compared to the conventional dopant p-toluenesulfonate (pTS). Electrical properties of DP and VA doped PEDOT were reduced in comparison to PEDOT/pTS, however co-doping with both DP and VA was shown to significantly improve the electroactivity of PEDOT in comparison to the individually doped coatings. Similarly, while the individually doped PEDOT coatings were mechanically friable, the inclusion of both dopants during electropolymerisation was shown to attenuate this response. In a whole-blood model of inflammation all DP and VA doped CPs retained their bioactivity, causing a significant reduction in levels of the pro-inflammatory cytokine TNF-α. These studies demonstrated that small charged bioactive molecules are able act as dopants for CPs and that co-doping with ions of varied size and doping affinity may provide a means of addressing the limitations of large bulky bimolecular dopants.
Glial scar encapsulation is thought to be one of the major reasons for the failure of chronic brain-machine interfaces. Many strategies, including modification of the probe surface chemistry, delivery of anti-inflammatory drugs, and... more
Glial scar encapsulation is thought to be one of the major reasons for the failure of chronic brain-machine interfaces. Many strategies, including modification of the probe surface chemistry, delivery of anti-inflammatory drugs, and changes of probe geometry, have been employed to reduce glial scar formation. We have proposed that a possible means to establish long-term, reliable communication across the scar is the in situ polymerization of conjugated polymers such as PEDOT in neural tissue. Previously, we exposed entire brain slices to the EDOT monomer. Here, we demonstrate that PEDOT can be polymerized by the direct delivery of EDOT monomer to the reaction site. The monomer was delivered into rat cortex via microcannula and simultaneously electrochemically polymerized within the tissue using a microwire electrode. We found that the resulting PEDOT polymer cloud grew out from the working electrode tip and extended far out into the brain tissue, spanning distances more than 1mm. We also examined the morphology of resulting polymer cloud by optical microscopy.
ABSTRACT This study examines the efficacy of primary and secondary nucleation for electrochemical polymerisation of conductive polymers within poly(vinyl alcohol) methacrylate hydrogels. The two methods of nucleation investigated were a... more
ABSTRACT This study examines the efficacy of primary and secondary nucleation for electrochemical polymerisation of conductive polymers within poly(vinyl alcohol) methacrylate hydrogels. The two methods of nucleation investigated were a primary heterogeneous mechanism via introduction of conductive bulk metallic glass (Mg64Zn30Ca5Na1) particles and a secondary mechanism via introduction of “pre-polymerised” conducting polymer within the hydrogel (PEDOT:PSS). Evidence of nucleation was not seen in the bulk metallic glass loaded gels, however, the PEDOT:PSS loaded gels produced charge storage capacities over 15 mC/cm2 when sufficient polymer was loaded. These studies support the hypothesis that secondary nucleation is an efficient approach to producing stand-alone conducting hydrogels.
ABSTRACT
Research Interests:
Research Interests:
Conducting polymers (CPs) have the potential to provide superior neural interfaces to conventional metal electrodes by introducing more efficient charge transfer across the same geometric area. In this study the conducting polymer... more
Conducting polymers (CPs) have the potential to provide superior neural interfaces to conventional metal electrodes by introducing more efficient charge transfer across the same geometric area. In this study the conducting polymer poly(ethylene dioxythiophene) (PEDOT) was coated on platinum (Pt) microelectrode arrays. The in vitro electrical characteristics were assessed during biphasic stimulation regimes applied between electrode pairs. It was demonstrated that PEDOT could reduce the potential excursion at a Pt electrode interface by an order of magnitude. The charge injection limit of PEDOT was found to be 15 x larger than Pt. Additionally, PEDOT coated electrodes were acutely implanted in the suprachoroidal space of a cat retina. It was demonstrated that PEDOT coated electrodes also had lower potential excursions in vivo and electrically evoked potentials (EEPs) could be detected within the vision cortex.
Research Interests:
ABSTRACT
Laser surface modification of platinum (Pt) electrodes was investigated for use in neuroprosthetics. Surface modification was applied to increase the surface area of the electrode and improve its ability to transfer charge within safe... more
Laser surface modification of platinum (Pt) electrodes was investigated for use in neuroprosthetics. Surface modification was applied to increase the surface area of the electrode and improve its ability to transfer charge within safe electrochemical stimulation limits. Electrode arrays were laser micromachined to produce Pt electrodes with smooth surfaces, which were then modified with four laser patterning techniques to produce surface structures which were nanosecond patterned, square profile, triangular profile and roughened on the micron scale through structured laser interference patterning (SLIP). Improvements in charge transfer were shown through electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and biphasic stimulation at clinically relevant levels. A new method was investigated and validated which enabled the assessment of in vivo electrochemically safe charge injection limits. All of the modified surfaces provided electrical advantage over the smooth Pt. The SLIP surface provided the greatest benefit both in vitro and in vivo, and this surface was the only type which had injection limits above the threshold for neural stimulation, at a level shown to produce a response in the feline visual cortex when using an electrode array implanted in the suprachoroidal space of the eye. This surface was found to be stable when stimulated with more than 150 million clinically relevant pulses in physiological saline. Critical to the assessment of implant devices is accurate determination of safe usage limits in an in vivo environment. Laser patterning, in particular SLIP, is a superior technique for improving the performance of implant electrodes without altering the interfacial electrode chemistry through coating. Future work will require chronic in vivo assessment of these electrode patterns.
Metal electrode materials used in active implantable devices are often associated with poor long-term stimulation and recording performance. Modification of these materials with conducting polymer coatings has been suggested as an... more
Metal electrode materials used in active implantable devices are often associated with poor long-term stimulation and recording performance. Modification of these materials with conducting polymer coatings has been suggested as an approach for improving the neural tissue-electrode interface and increasing the effective lifetime of these implants. Neural interfaces ideally have intimate contact between the excitable tissue and the electrode to maintain signal quality and activation of neural cells. The outcomes of current research into conducting polymers as coatings has potential to enhance this tissue-material contact by increasing the electrode surface area and roughness as well as allowing delivery of bioactive signals to neural cells. However, challenges facing conducting polymers include poor electroactive stability and mechanical properties as well as control of the mobility, concentration and presentation of bioactive molecules. The impact of biological inclusions on polymer ...
Soft, cell integrated electrode coatings are proposed to address the problem of scar tissue encapsulation of stimulating neuroprosthetics. The aim of these studies was to prove the concept and feasibility of integrating a cell loaded... more
Soft, cell integrated electrode coatings are proposed to address the problem of scar tissue encapsulation of stimulating neuroprosthetics. The aim of these studies was to prove the concept and feasibility of integrating a cell loaded hydrogel with existing electrode coating technologies. Layered conductive hydrogel constructs are embedded with neural cells and shown to both support cell growth and maintain electro activity. The safe charge injection limit of these electrodes was 8 times higher than conventional platinum (Pt) electrodes and the stiffness was four orders of magnitude lower than Pt. Future studies will determine the biological cues required to support stem cell differentiation from the electrode surface.
ABSTRACT
Glial scar encapsulation is thought to be one of the major reasons for the failure of chronic brain-machine interfaces. Many strategies, including modification of the probe surface chemistry, delivery of anti-inflammatory drugs, and... more
Glial scar encapsulation is thought to be one of the major reasons for the failure of chronic brain-machine interfaces. Many strategies, including modification of the probe surface chemistry, delivery of anti-inflammatory drugs, and changes of probe geometry, have been employed to reduce glial scar formation. We have proposed that a possible means to establish long-term, reliable communication across the scar is the in situ polymerization of conjugated polymers such as PEDOT in neural tissue. Previously, we exposed entire brain slices to the EDOT monomer. Here, we demonstrate that PEDOT can be polymerized by the direct delivery of EDOT monomer to the reaction site. The monomer was delivered into rat cortex via microcannula and simultaneously electrochemically polymerized within the tissue using a microwire electrode. We found that the resulting PEDOT polymer cloud grew out from the working electrode tip and extended far out into the brain tissue, spanning distances more than 1mm. We...
Recent interest in the use of conducting polymers (CPs) for neural stimulation electrodes has been growing; however, concerns remain regarding the stability of coatings under stimulation conditions. These studies examine the factors of... more
Recent interest in the use of conducting polymers (CPs) for neural stimulation electrodes has been growing; however, concerns remain regarding the stability of coatings under stimulation conditions. These studies examine the factors of the CP and implant environment that affect coating stability. The CP poly(ethylene dioxythiophene) (PEDOT) is examined in comparison to platinum (Pt), to demonstrate the potential performance of these coatings in neuroprosthetic applications. PEDOT is coated on Pt microelectrode arrays and assessed in vitro for charge injection limit and long-term stability under stimulation in biologically relevant electrolytes. Physical and electrical stability of coatings following ethylene oxide (ETO) sterilization is established and efficacy of PEDOT as a visual prosthesis bioelectrode is assessed in the feline model. It was demonstrated that PEDOT reduced the potential excursion at a Pt electrode interface by 72% in biologically relevant solutions. The charge injection limit of PEDOT for material stability was found to be on average 30× larger than Pt when tested in physiological saline and 20× larger than Pt when tested in protein supplemented media. Additionally stability of the coating was confirmed electrically and morphologically following ETO processing. It was demonstrated that PEDOT-coated electrodes had lower potential excursions in vivo and electrically evoked potentials (EEPs) could be detected within the visual cortex. These studies demonstrate that PEDOT can be produced as a stable electrode coating which can be sterilized and perform effectively and safely in neuroprosthetic applications. Furthermore these findings address the necessity for characterizing in vitro properties of electrodes in biologically relevant milieu which mimic the in vivo environment more closely.
Multi-walled carbon nanotubes (MWNTs) can be incorporated into conductive polymers to produce superior materials for neural interfaces with high interfacial areas, conductivity and electrochemical stability. This paper explores the... more
Multi-walled carbon nanotubes (MWNTs) can be incorporated into conductive polymers to produce superior materials for neural interfaces with high interfacial areas, conductivity and electrochemical stability. This paper explores the addition of MWNTs to polypyrrole (PPy) through two methods, layering and codeposition. Conductivity of PPy doped with polystyrene sulfonate (PSS), a commonly used dopant, was improved by 50% when MWNTs were layered with PPy/PSS. The film electrochemical stability was improved from 38% activity to 66% activity after 400 cycles of oxidation and reduction. Growth inhibition assays indicated that MWNTs are not growth inhibitory. The electroactive polymer-MWNT composites produced demonstrate properties that suggest they are promising candidates for biomedical electrode coatings.
Conducting polymers have often been described in literature as a coating for metal electrodes which will dampen the mechanical mismatch with neural tissue, encouraging intimate cell interactions. However, there is very limited... more
Conducting polymers have often been described in literature as a coating for metal electrodes which will dampen the mechanical mismatch with neural tissue, encouraging intimate cell interactions. However, there is very limited quantitative analysis of conducting polymer mechanics and the relation to tissue interactions. This article systematically analyses the impact of coating platinum (Pt) electrodes with the conducting polymer poly(ethylene dioxythiophene) (PEDOT) doped with a series of common anions which have been explored for neural interfacing applications. Nanoindentation was used to determine the coating modulus and it was found that the polymer stiffness increased as the size of the dopant ion was increased, with PEDOT doped with polystyrene sulfonate (PSS) having the highest modulus at 3.2 GPa. This was more than double that of the ClO4 doped PEDOT at 1.3 GPa. Similarly, the electrical properties of these materials were shown to have a size dependent behavior with the smaller anions producing PEDOT films with the highest charge transfer capacity and lowest impedance. Coating stiffness was found to have a negligible effect on in vitro neural cell survival and differentiation, but rather polymer surface morphology, dopant toxicity and mobility is found to have the greatest impact.
Bioelectrodes for neural recording and neurostimulation are an integral component of a number of neuroprosthetic devices, including the commercially available cochlear implant, and developmental devices, such as the bionic eye and... more
Bioelectrodes for neural recording and neurostimulation are an integral component of a number of neuroprosthetic devices, including the commercially available cochlear implant, and developmental devices, such as the bionic eye and brain-machine interfaces. Current electrode designs limit the application of such devices owing to suboptimal material properties that lead to minimal interaction with the target neural tissue and the formation of fibrotic capsules. In designing an ideal bioelectrode, a number of design criteria must be considered with respect to physical, mechanical, electrical and biological properties. Conducting polymers have the potential to address the synergistic interaction of these properties and show promise as superior coatings for next-generation electrodes in implant devices.
Conducting polymer (CP) coatings on medical electrodes have the potential to provide superior performance when compared to conventional metallic electrodes, but their stability is strongly dependant on the substrate properties. The aim of... more
Conducting polymer (CP) coatings on medical electrodes have the potential to provide superior performance when compared to conventional metallic electrodes, but their stability is strongly dependant on the substrate properties. The aim of this study was to examine the effect of laser roughening of underlying platinum (Pt) electrode surfaces on the mechanical, electrical and biological performance of CP coatings. In addition, the impact of dopant type on electrical performance and stability was assessed. The CP poly(ethylene dioxythiophene) (PEDOT) was coated on Pt microelectrode arrays, with three conventional dopant ions. The in vitro electrical characteristics were assessed by cyclic voltammetry and biphasic stimulation. Results showed that laser roughening of the underlying substrate did not affect the charge injection limit of the coated material, but significantly improved the passive stability and chronic stimulation lifetime without failure of the coating. Accelerated material ageing and long-term biphasic stimulus studies determined that some PEDOT variants experienced delamination within as little as 10 days when the underlying Pt was smooth, but laser roughening to produce a surface index of 2.5 improved stability, such that more than 1.3 billion stimulation cycles could be applied without evidence of failure. PEDOT doped with paratoluene sulfonate (PEDOT/pTS) was found to be the most stable CP on roughened Pt, and presented a surface topography which encouraged neural cell attachment.
... 708 Nanostructured Conductive Polymers Page 3. The vision prosthesis, also known as the bionic eye, is a stimulating device which is currently under development. ...Nanostructured Conductive Polymers as Biomaterials 709 Page 4. ...