Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Vanpanel Wall: External and Internal Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

WALL Fire resistance

VANPANEL WALL

Profiled wall systems, Insulated with fire resistant rockwool insulation

Self-supporting metal panel system insulated with,rockwool for wall and partition applications. The VANPANEL WALL panel consists of two micro-ribbed steel sheets, with an insulation core of orientated fibre high density rockwool, arranged perpendicularly to the plane of the panel and positioned in strips, laid longitudinally with off-set joints and transversely compacted, in such a way as to completely fill the space between the metal facings. Maximum panel lenght: L = 15,000 mm. External and internal sheet
The following materials can be used: - Prepainted galvanised steel - Prepainted Aluminium Alloy Nominal thickness: 0.40 0.70 mm Paint: Polyester, PVF2

Insulation

Rockwool, density: 80 - 100 kg./m3 Thickness: 50 - 80 - 100 mm.

Reaction to fire

Non combustible when tested in accordance with BS-476 part - 4 and ASTME-136. Class I, when tested in accordance with BS-476 part 7 and ASTME -84. Fire Resistant with integrity up to 240 min. and insulation up to 196 min,when tested as per BS-476 part-20. Table of safe spans Values guaranteed with steel sheets, thickness 0.5 + 0.5 mm. The spans l in metres, as a function of a uniformly distributed load p (daN/m2), deflection limit: f < 1/200 of the span.

S
mm
Kcal m2 h C

Watt m2 C

Panel weight kg/m2 0.5 + 0.5 P (daN/m2) 40

MULTI SPAN

MULTI SPAN

60

80

100

120

150

40

60

80

100

120

150

50 80 100

0.65 0.42 0.34

0.75 0.49 0.4

14.4 17.4 19.4

I= I= I=

4.38 5.55 6.21

3.58 4.53 5.07

2.73 3.92 4.39

2.18 3.51 3.58

1.82 2.93 3.58

1.45 2.34 2.94

3.92 4.96 5.55

3.20 4.05 4.53

2.46 3.51 3.93

1.96 3.14 3.51

1.64 2.64 3.21

1.31 2.11 2.64

VAN INTERNATIONAL

P.O.BOX 40424 SHARJAH - UAE

- TEL: (009176) 5340553 - FAX: +9716 5340540

ROCKWOOL INSULATION CONFORMANCE STANDARD CONFORMANCE


ASTM C 612 "Standard Specification for Mineral Fiber Block and Board Thermal Insulation" BS 3958 Part 5 "Specification for bonded man-made mineral fiber slabs. ASTM C 795 "Standard Specification for Thermal Insulation for use in contact with austenitic stainless steel" Can be used to satisfy BS 5422 "Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment"

PROPERTIES
DENSITY LENGTH WIDTH THICKNESS WEIGHT SERVICE TEMPERATURE NON - COMBUSTIBILITY FIRE RESISTANCE BURNING CHARACTERISTIC THERMAL CONDUCTIVITY

TEST METHOD

ASTM C 303 BS 2972 Section 3 ASTM C 447/ C 411 & DIN 52271 BS 476 Part 4 & ASTM E 136 BS 476 Part 20 & ASTM E 119 ASTM E 84 ASTM C 177 / C 518, ISO 8302/ISO 8301 EQUIVALENT TO BS 874, DIN 52612 BS 3638/ISO 354 ASTM C 423 - Sound Absorption ASTM E 90 - Sound Transmission Loss ASTM E 413 - Sound Transmission Class ASTM C 165 ASTM C-871 BS 2972 Section 21 AGIQ135 ASTM C 692 (Pre-production Corrosion Test) ASTM C 1335 / BS 2972 SECTION 14 ASTM C 209 SECTION 14 / BS 2972 SECTION 12 ASTM C 1104 / C 1104 M ASTM E 96/ E 96M ASTM C 1304 ASTM C 356 ASTM C 1101 / 1101M

ACOUSTICAL PROPERTIES COMPRESSION RESISTANCE CHEMICAL ANALYSIS CHLORIDE FLUORIDE PH CORROSION TEST SHOT CONTENT WATER ABSORPTION WATER VAPOUR SORPTION WATER VAPOUR TRANSMISSION ODOR EMISSION LINEAR SHRINKAGE RIGIDITY AND FLEXIBILITY CLASSIFICATION

VAN INTERNATIONAL

P.O.BOX 40424 SHARJAH - UAE

- TEL: (009176) 5340553 - FAX: +9716 5340540

Thermal Conductivity: in accordance with BS 874, Equivalent ASTMC 177/C 518 and DIN 52612 standards. Mean Temp C
10 50 100 150 200 250 300 350 400

k-value W/mk 80 kg/m3


0.033 0.038 0.046 0.054 0.066 0.080 0.096 0.115 0.134

k-value W/mk 100 kg/m3


0.033 0.037 0.044 0.052 0.061 0.072 0.084 0.098 0.118

Service Temperature: Can withstand temperature up to 750 C when tested in accordance with DIN 52271 and ASTMC - 411

Acoustical Properties: Typical sound absorption figures are shown below in accordance with BS 3638 & ISO 0354: Hz
125 250 500 1000 2000 4000

70 kg/m3
0.22 0.62 0.91 1.00 1.00 0.98

100 kg/m3
0.23 0.66 1.05 1.07 1.05 0.97

Compatibility: Compatible with all forms of material with which it is likely to come in contact in normal industrial and building applications. Moisture: Water-repellent, non-hygroscopic, non-capillary, and does not absorb any moisture from air,Moisture has no effect on stability of slabs. Water absorption test certificate conducted under BS 2972 : Section 12 and ASTMC 209 are available upon request. Chemical Neutrality: Chemically neutral with a pH value of 7.3 when tested in accordance with BD 2972 : Section 22 and ASTMC-871. It will neither cause nor promote corrosion. It meets the requirements of the standard specification for use over austenitic stainless steel as per ASTM C - 692 ( Corrosion ) test and ASTM C -871 ( Chemical Analysis ). It contains low level of chlorides when tested in accordance with BS 2972 : Section 21 and ASTMC 871. Biological properties: Rot-proof, non-hygroscopic, will not sustain vermin and will not encourage growth of bacteria, mould or fungi. Physical properties: Asbestos free and shot content is very low when tested as per ASTM C 612 and BS-2972

VAN INTERNATIONAL

P.O.BOX 40424 SHARJAH - UAE

- TEL: (009176) 5340553 - FAX: +9716 5340540

You might also like