PT.

QUATRA POWER ENGINEERING

VESSEL DATA SHEET


1 2 SERVICE OWNER : FUEL GAS FILTER : PERTAMINA PHE ONWJ

PROJECT NO. PROJECT NAME EQUIPMENT NAME TAG NO CLIENT DOCUMENT NO FILTER VESSEL MODEL NO. 3 QUANTITY 4 TYPE

XXXXX BRAVO Compressor Control System Upgrade Project FUEL GAS FILTER 03-V- 8C/8D BRAVO-M-DSH-0001 : 2 (TWO) : VERTICAL FILTER SEPARATOR

PROCESS DESIGN DATA


5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 23 6 7 8 9 10 11 12 13 14 15 16 17 18 13 14 15 16 17 18 19 20 21 22 23 24 25 37 38 39 40 41 45 46 47 48 49 50 51 Fluid Handled Flammabel / Toxic / Corrosive / Lethal Operating Temperature - Normal Operating Temperature - Maximum Operating Temperature - Minimum Operating Pressure - Normal Operating Pressure - Maximum Operating Pressure - Minimum
Pressure Drop (Clean / Change Out) (2 Fuel Gas

105.2 240 (0.4/10)

0 0

Setting Velocity of Solid Sieve Analysis of Solids Desc. of Particle Removed: Gas Density Gas Compressibility Gas Molecular Weight Liquid Density Sump OD Max. Liquid Handling Capacity of the Filter Design Temperature Design Pressure Internal Vacuum Corrosion Allowance Cladding Thickness Test Pressure Shop = 1.5 X MAP N&C Test Pressure Site Vessel Diameter (OD) Vessel Length (Sm-Sm) Vessel Orientation Type of Bottom Shell Thickness (Nominal Thickness) Head Thickness (Nominal Thickness) Vessel Code Vessel Specification Shell Heads Leg Support Internals: Filter Element Riser Assembly Vane Vane Boxing Insulation Rings Grounding Lugs Surface Preparation Painting/Coating Erection Weight Empty Weight Inside Inside

0.7888 0.01100 18.05 61.615 200 675 0.125 350 4714 VERTICAL 0.4380 0.4380

F F 0 F Psig Psig Psig psid fps

24 25 26 27 28 29 30 31 32 33 34

Gas Flowrate Liquid Flowrate Liquid Rate Specific Gravity - Condensate (density) Specific Gravity - Water (density) Turn Down Efficiency Particle Size - Solid Filtration Efficiency Particle Size - Liquid Filtration Efficiency

6.6

10 : 1 1.0 99.98 3.0 99.98

MMSCFD lb/hr BLPD lbs/ft3 lbs/ft3

% %

lb/ft3 cP 1 2 3 4 5 Filter Element Type Quantity of Filter Element Element Area Diameter Riser Assy Cyclone

18 Gas Viscosity

INTERNAL
GCA5536K10V 3 ea 327.66 mm YES YES

lb/ft3 inch GPM


0

MECHANICAL DESIGN DATA


F Psig 1 2 3 4 5 6 7 8 9 10 11 12 Support Type Sour Service Relief Valve Set Pressure Explosion Blast Load Wind Velocity Seismic Factor Soil Profile Transport Loading Total Volume Normal Liquid Volume Insulation Thickness Fire Proofing LEGS NO NO NO

inch mm Psig Psig mm mm

Psig m/s

2 : 1 ELLIPSOIDAL

inch inch

ft3 ft3 mm mm

CODE AND SPECIFICATION


: ASME Section VIII, DIV.1, Latest Edition, Latest Addenda : AS PER SPEC

MATERIALS
SA 106 Gr. B SA 234 WPB SA 283 Gr. C A 36/ SS 400 Polyester SS 316L SS 316L SS 316L N/A SA 516 Gr. 70
: AS PER SPEC : AS PER SPEC

26 27 28 29 30 31 32 33 34 35 36

Flanges Nozzle Necks :

Pipes Plates Forgings

Welding Fittings Reinforcement Pad Externals Bolts Externals Nuts Externals Gasket Lifting Lugs Anchor/Setting Bolts

SA 105 SA106 Gr B SA 516 Gr 70 SA 105 SA 234 WPB SA 516 Gr 70 A 193 Gr B7 Fluorocarbon Coated A 194 2H Cad Plated Fluorocarbon Coated 304 SS Spiral Wound YES N/A
: AS PER SPEC : AS PER SPEC

PROTECTIVE COATING DATA


Outside Outside 42 Test Weight 43 Operating Weight 44 52 53 54 55 56 57 58 Hydrostatic Test Pneumatic Test Impact Test PWHT / Stress Relief Special Heat Treatment Hardness Test Material Certificate YES PER CODE PER CODE PER CODE PER CODE PER CODE YES

ESTIMATE WEIGHTS
lbs lbs lbs lbs

FABRICATION AND INSPECTION REQUIREMENTS


Regulating & Inspection Authority Code Stamped Inspection Authority Radiography Test Ultrasonic Test Magnetic Particle Test Dye Penetrant Test MIGAS NO BY MIGAS FULL PER CODE PER CODE PER CODE