Table A-6 Basic Tension Development-Length Ratio, (In./in.) / D

The document provides tables of basic tension development-length ratios for reinforcing bars in concrete. The tables give the ratios for various bar sizes, steel yield strengths, and concrete compressive strengths. The ratios are expressed as the required development length divided by the bar diameter. Shorter development lengths are required for higher strength steel and concrete. Two cases are outlined for development length calculations depending on clear spacing and cover requirements.

Uploaded by

qaiserkhan001
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
604 views

Table A-6 Basic Tension Development-Length Ratio, (In./in.) / D

The document provides tables of basic tension development-length ratios for reinforcing bars in concrete. The tables give the ratios for various bar sizes, steel yield strengths, and concrete compressive strengths. The ratios are expressed as the required development length divided by the bar diameter. Shorter development lengths are required for higher strength steel and concrete. Two cases are outlined for development length calculations depending on clear spacing and cover requirements.

Uploaded by

qaiserkhan001
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TABLE A-6

Basic Tension Development-Length Ratio, /d > db (in./in.)


/d = fc = 3 0 0 0 p si /d ce * * db, but not less than 12 in.a db l fc = 4 0 0 0 p si Bottom Bar Top Bar fc = 5 0 0 0 p si Bottom Bar Top Bar fc = 6 0 0 0 p si Bottom Bar Top Bar

fc = 3 7 5 0 p si Bottom Bar Top Bar

Bar No.

Bottom Bar

Top Bar

Case 1: Clear spacing of bars being developed or spliced not less than db, clear cover not less than db, and stirrups or ties not less than the ACI Code minimum, throughout /d
or

Case 2: Clear spacing of bars being developed or spliced not less than 2db and clear cover not less than db. fy = 60,000 psi, uncoated bars, normal-weight concrete 3 to 6 7 to 18 43.8 54.8 57.0 71.2 39.2 49.0 50.9 63.7 37.9 47.4 49.3 61.7 33.9 42.4 44.1 55.2 31.0 38.7 40.3 50.3

fy = 40,000 psi, uncoated bars, normal-weight concrete 3 to 6 29.2 Other Cases fy = 60,000 psi, uncoated bars, normal-weight concrete 3 to 6 7 to 18 65.7 82.2 85.4 106.8 58.8 73.5 76.4 95.6 56.9 71.1 74.0 92.6 50.9 63.6 66.2 82.8 46.5 58.1 60.5 75.5 38.0 26.1 34.0 25.3 32.9 22.6 29.4 20.7 26.9

fy = 40,000 psi, uncoated bars, normal-weight concrete Appendix A 3 to 6


a

43.8

57.0

39.2

51.0

38.0

49.4

33.9

44.1

31.1

40.4

ce coating factor; l, lightweight-concrete factor.