Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Johnson Controls Hvac Equipments Controls Katalog 2010

Download as pdf or txt
Download as pdf or txt
You are on page 1of 52
At a glance
Powered by AI
The document is a product catalogue from Johnson Controls that provides information on their range of HVAC and building control products.

Johnson Controls offers a wide range of linear actuators, rotary actuators, valves, sensors, thermostats and other HVAC equipment.

The catalogue highlights features like cutting edge solutions, first class performance, uncompromised quality, unrivaled efficiency and long term savings.

CONTROLS, AIR-CONDITIONING & REFRIGERATION PRODUCTS

The UK Products Catalogue


2010
2
In 1883, Warren S. Johnson, a professor at the State
Normal School in Whitewater, Wisconsin, received
a patent for the first electric room thermostat. His
invention launched the building control industry and
was the impetus for a new company.
Welcome to the new issue of our
UK Product Catalogue.
All your familiar, market leading products are
here in an easy-to-find format. Each item is
clearly marked with supporting information,
accessories and list prices.
We hope you will find this catalogue useful
and informative.
Commitment to innovation and dedication to excellence is central to our business.
We see challenges as opportunities to develop breakthrough, high-performance
products and reliable solutions that deliver lasting value to our customers.
We recognise that HVAC professionals expect the best building controls.
So if you want to promise your customers the benefits of:
Cutting edge solutions which are quick and easy to install
First class performance with uncompromising quality
Unrivalled operational efficiency and significant long-term savings
... then specify a Johnson Controls product.
All our products are laboratory and field tested for a long, trouble free life.
Many are sold in the millions Worldwide and are still operating efficiently after
decades of operation.
Finally, we keep thousands of products in our European central warehouse
to guarantee the fastest possible delivery and meet all your HVAC needs.
This catalogue shows only a small part of Johnson Controls extensive range so
if you cant see the product you require please contact our Sales Support Team.
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
3
INDEX
LINEAR ACTUATORS Page
For Terminal Unit Valves VA-7010, VA-7040, VA-7060,
VA-7450, VA-747x 4-5
For Plant Valves PA-2000, RA-3000, VA-1000,
VA-7150, VA-7200, VA-7310,
VA-7700, VA-7800 5-7
ROTARY ACTUATORS
Silence and Small Family M910x, M9304 7-8
Standard Family M91xx 8-9
Spring Return Family M9206, M9208, M92x0, M9216 9-10
Special and Security Family M91xx, M91xx, M9116 11
Valve Family VA9104, M9108, M9116, M9206 12-13
VALVES
Modulating Water Valves V46, V46SA, V47, V48 13-15
Terminal Unit Valves V5000, VG5000, VG6000 15-17
Threaded Control Valves VG1201, VG1801, VG7000 17-19
Flanged Control Valves VG8000N, VG8000V 19-20
Gas Valves GH-5000 20
SENSORS / THERMOSTATS
CO
2
Sensors CD-WOO, CD-Wxx, CD-Pxx 20-21
Dew Point Sensors HX-9100 21
Flow and Float Controls F61, F62, F63 21-22
Humidity Sensors HT-1000, HT-9000 22-23
Pressure Transmitters DP2500, DP0100, DP0250, PT-5217 23
Pressure Switches P232, P233, P20, P28, P45, P74,
P48, P735, P736, P77, P78, P100,
Accessories, H735 23-29
Pressure Transducers P35, P499 30
Room Controllers TC-8900, PM-8900, ES-89xx,
TEC-2000 31-32
Capillary and Space A19, A25, A28, A36, 270XT,
Thermostats T22 and T25, Accessories 32-34
Temperature Sensors TE-7000, RS-1100, TM-1100,
TM-2100, TS-9100, TE-9100 34-36
ELECTRO-PNEUMATIC TRANSDUCERS
Transducers EP-1000, EP-2000, EP-8000 37
REFRIGERATION CONTROLLERS
Field Controls MS, CR 38-39
Fan Speed Controllers P215PR, P215DP/SH/ST,
P255LR/BR/TR 40-41
STYLE REFERENCE & WIRING DIAGRAMS 42
SELECTION REFERENCE TABLES 43-44
GENERAL ORDERING INFORMATION 45
RMA REQUEST FORM 46
GENERAL CONDITIONS OF SALE 47-50
VALVE SIZING DISC AND DATA SHEETS 51
NEW PRODUCTS
M
9
2
0
8

S
e
r
i
e
s
8 Nm Spring Return Actuators
(see page 9)
H
T

S
e
r
i
e
s
Room Humidity Sensors
(see page 22)
V
A
-
1
0
0
0

S
e
r
i
e
s
2000N & 2500N Linear Actuators
(see page 6)
D
P

S
e
r
i
e
s
Differential Pressure Transmitters
(see page 23)
V
5
0
0
0

S
e
r
i
e
s
DN10-20, PN16 Valves
(see page 15)
T
M
-
1
1
0
0

S
e
r
i
e
s
Room Command Modules
(see page 35)
Sales Support Team
Contact Us: Telephone 01753 870300
Fax 0870 889 5664
Email products.uk@jci.com
Customer Mita Virdee, Cynthia Hutson & Tony Vickers
Service: - Sales order processing
- Availability and lead time information
- Price enquiries
- Returns processing
Technical Mark Delisser - Products
Support: David Newton - Access card specialist
- Product application and technical support
- Datasheet and literature requests
- Compatibility and obsolete product guidance
Finance: Telephone 01753 870300
- Customer accounts and credit approval
- Credit control and collection
- Credit notes and customer account queries
Field Sales: Graham Vail - UK South 0777 980 8349
Peter OMalley - UK North 0777 980 8348
Kevin Kirby - OEM Sales 0777 980 8525
Valve Sizing Software
A copy of our control valve sizing software HIPPOS has been
included in the back of this catalogue. This industry leading tool
allows the sizing, selection and listing of control valves and
actuators saving huge amounts of time in the selection and
records of valves for a project. You can easily export the schedule
to the O&M Manual too!
4
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
Linear Actuators - for Terminal Unit Valves
VA-7010 Series
90N,ON/OFF Control
The VA-7010 electric actuator provides a two-position
(open-closed) control and can easily be mounted
with a threaded mounting nut onto VG5000
terminal unit valves.
A lever at the side of the actuator housing can
be used to manually open a 2-way PDTO valve or
the normally closed port of a 3-way valve.
FEATURE
Manual lever
Ordering Codes
Supply
Voltage Stroke Time Force
List
Price
VA-7010-8101 24Vac 10 sec. (actuator stem extends)
90N
44
VA-7010-8103 230Vac 5 sec. (actuator stem retracts) 44
Stroke - 3mm (max. 5mm)
Mounting - Threaded nut M28 x 1.5
Cable - 1.5m length
Size - 75 x 65 x 63mm
Protection Class - IP40
VA-7040 Series
125N, ON/OFF or DAT Control, Thermal
The VA-704x actuators provide ON/OFF or DAT control in
HVAC applications. The compact design of these actuators
make them suitable for installations in confined spaces,
such as fan-coil applications.
The VA-704x are designed for field mounting onto
VG5000 and V5000 terminal unit valves.
FEATURES
Configurable to direct or reverse action
Threaded mounting nut (M28 x 1.5 for VG5000 or
M30 x 1.5 for V5000 or 3rd party valves)
Ordering Codes Supply Voltage
Action
Control * Force
List
Price
VA-7040-21
24Vac/dc
Extends (DA)
125N
24
VA-7047-21 33
VA-7048-21 Retracts (RA) 37
VA-7040-23
230Vac
Extends (DA)
125N
30
VA-7047-23 30
VA-7048-23 Retracts (RA) 37
* Stem action when energised
Stroke - 4.5mm
Cable - 2m length
Sizes - 32 x 69mm, 34 x 69mm
Protection Class - IP44
VA-7060 Series
125N, Proportional Control, Thermal
The compact design of these actuators make them suitable for
installations in confined spaces, such as fan-coil and HVAC
applications.
The VA-706x actuators are designed for field mounting
onto VG5000 and V5000 terminal unit valves.
FEATURES
Configurable for direct or reverse action
Threaded mounting nut (M28 x 1.5, M30 x 1.5 or third party valves)
Ordering Codes
Supply
Voltage Stem Action * Force
List
Price
VA-7060-21
24Vac/dc Extends (DA) 125N
79
VA-7067-21 68
* Stem action when energised
Stroke - 4.5mm
Cable - 2m length
Sizes - 32 x 69mm, 34 x 69mm
Protection Class - IP44
VA-7450 Series
120N, Floating or Proportional Control (M28 mounting)
The VA-7450 series provides floating or proportional
control. Their compact design makes them suitable for
installation in confined spaces, such as fan coil applications.
They are designed for field mounting onto VG5000
terminal unit valves.
FEATURES
Self calibrating
Configurable to direct or reverse action
Configurable anti-sticking cycle
Configurable split ranging
Ordering Codes
Supply
Voltage Action Control Force
List
Price
VA-7450-1001
24Vac
Floating
120N
58
VA-7452-1001 Proportional * 85
VA-7452-9001 Proportional ** 73
Notes: Models with longer cable or different mounting nut, are available on request.
* Fixed factory setting: 0-10Vdc input direct acting anti-sticking disabled
** Fully configurable: input signal (0-10V, 5-10V, 0-5V) action (direct or reverse
acting) anti-sticking (disable or enable)
Stroke - 3mm (max. 5mm)
Full Stroke Time - 45 sec
Cable - 1.5m length
Mounting - Threaded nut (M28 x 1.5)
Size - 74 x 47 x 69.5mm
Protection Class - IP40
ACCESSORY
Ordering Codes Description Price
VA-7450-8900 Manual Override Ring for VG5000 27
LINEAR ACTUATORS
5
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
RA-3000 Series
1600 and 3000N, Floating or
Proportional Control
The RA-3000 series synchronous motor-driven, reversible
actuators feature factory calibrated pressure switches to provide
specified close-off ratings. These actuators can be used with
flanged valves according to maximum close-off pressure
ratings specified.
FEATURES
Uses synchronous motor with pressure switches
Special clamp coupler quick-fit systems
Positioner with adjustable starting point, span and direct/reverse action
Optional auxiliary switches, feedback potentiometer and hand crank
Ordering Codes
Supply
Voltage Force
Hand
Crank
Variations* List
Price
Y Z
RA-3000-7126
24V
1600N
- 432
RA-3003-7126

536
RA-3041-7126

703
RA-3100-7126

758
RA-3103-7126

1,041
RA-3141-7126

770
RA-3000-7127
230V
484
RA-3003-7127

965
RA-3100-7127

780
RA-3103-7127

1,041
RA-3000-7226
24V
1800N
401
RA-3003-7226

529
RA-3041-7226

629
RA-3100-7226

468
RA-3103-7226

584
RA-3141-7226

711
RA-3000-7227
230V
401
RA-3003-7227

965
RA-3100-7227

780
RA-3103-7227

2,973
RA-3000-7325
24V
(60Hz)
3000N
588
RA-3003-7325 2,973
RA-3041-7325

1,175
RA-3100-7325

858
RA-3103-7325

1,039
RA-3141-7325

1,239
RA-3000-7326
24V
(50Hz)
3000N
474
RA-3003-7326

620
RA-3041-7326

704
RA-3100-7326

594
RA-3103-7326

662
RA-3141-7326

836
RA-3000-7327
230V
(50Hz)
3000N
474
RA-3003-7327

973
RA-3100-7327

882
RA-3103-7327

722
RA-3000-7328
230V
(60Hz)
3000N
792
RA-3003-7328

973
RA-3100-7328

858
RA-3103-7328

1,039
* Variations:
Y = Two auxiliary switches and two 2 k feedback potentiometers
Z = Built-in positioner 0-10Vdc and two auxiliary switches (only 24Vac models)
Supply Voltage - 24V or 230V, 50/60Hz
Nominal Stroke - 13mm (1600N), 25mm (1800N), 42mm (3000N)
Auxiliary Switches - 5(3)A, 230V 50/60Hz
Size - 345 x 186 x 186mm
Protection Class - IP54
VA-747x Series
120N, Floating or Proportional Control
(M30 mounting)
These actuators provide incremental or proportional control
in terminal unit valve applications. Their compact design
makes them suitable for installation in confined spaces,
such as fan coil applications.
They are designed for field mounting onto VG6000
and V5000 terminal unit valves.
FEATURES
Self calibrating
Configurable to direct or reverse action
Configurable anti-sticking cycle
Configurable split ranging
Ordering Codes
Supply
Voltage Action Control Force
List
Price
VA-7470-1001
24Vac
Floating
120N
84
VA-7472-1001 Proportional * 84
VA-7472-9001 Proportional ** 84
Notes: Models with longer cable or different mounting nut, are available on request.
* Fixed factory setting: 0-10Vdc input direct acting anti-sticking disabled
** Fully configurable: input signal (0-10V, 5-10V, 0-5V) action (direct or reverse
acting) anti-sticking (disable or enable)
Stroke - 3mm (max. 5mm)
Full Stroke Time - 45 sec
Mounting - Threaded nut (M30 x 1.5)
Cable - 1.5m length
Size - 74 x 47 x 69.5mm
Protection Class - IP40
PA-2000 Series
ON/OFF Control (Pneumatic)
PA-2000 actuators can be combined with VG8000 (H, N, V)
and VG8300 (H, N) series in accordance with the maximum
close-off pressure ratings specified.
The fail safe position can be changed in-situ with a
conversion kit.
FEATURES
Manual override
Teflon free series
Reversible action in-situ
Accessories available
Ordering Codes* Spring Range
Diaphram
Area Stroke Handwheel
List
Price
PA-20xy-Z2K2 20-50 kPa
150cm
2
13mm
POA
PA-21xy-Z2K7 70-100 kPa

POA
PA-20xy-Z3K2 20-50 kPa
300cm
2
25mm
POA
PA-21xy-Z3K7 70-100 kPa

POA
PA-20xy-Z6K2 20-50 kPa
600cm
2
42mm
POA
PA-21xy-Z6K7 70-100 kPa

POA
PA-20xy-Z7K2 20-50 kPa
25mm
POA
PA-21xy-Z7K7 70-100 kPa

POA
Notes: *x: 0 = Without positioner
3 = With positioner (PR10)
y: 0 = Without switches and potentiometer
3 = 2 Auxiliary switches and 2 k feedback potentiometer
Z: 3 = Standard models
9 = Teflon free
K: 1 = DA Actuator stem extend (spring return UP)
2 = RA Actuator stem retract (spring return DOWN)
Please call our Sales Support Team for your requirements and list prices.
Linear Actuators - for Plant Valves
6
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
VA-7310 Series
150N, Floating or Proportional Control
These actuators can be mounted onto VG7000 globe
valves with a slotted stem (VG7xxxxS).
FEATURES
Manual override using a standard 5mm allen key
Configurable for direct or reverse action
Ordering Codes
Supply
Voltage Action Control Force
List
Price
VA-7310-8001
24Vac
Floating
150N
(20%)
69
VA-7312-8001 Proportional 117
Supply Voltage - 24Vac, 50Hz
Nominal Stroke - 8mm (max. 10mm)
Full Stroke Time - 60 sec.
Size - 103 x 74 x 110mm
Protection Class - IP40
VA-7200 Series
1000N, Floating or Proportional Control
This synchronous motor driven actuator provides control of
valves with up to 19mm stroke.
These actuators can be easily field mounted or ordered
factory coupled to VG7000, VG8000 (H, N, V), VG9000
and VGS800 series valves in accordance with the specified
maximum close-off pressure ratings.
FEATURES
Compact unit for 1000N force output
Magnetic clutch
Signal fail safe position
Ordering Codes
Supply
Voltage Action Control Force
List
Price
For VG7000 Series Valves
VA-7200-1001
24Vac
Floating
1000N
200
VA-7202-1001 Proportional 297
For VG8000 / VG9000 / VGS8000 Series Valves
VA-7200-8201
24Vac
Floating
1000N
238
VA-7202-8201 Proportional 289
Supply Voltage - 24Vac, 50/60Hz
Action Control - Floating or Proportional 0-10Vdc, 0(4)-20mA
Nominal Stroke - 20mm max.
Size - 198 x 106mm, 198 x 225mm
Protection Class - IP40 or IP42
VA-7150 Series
500N, Floating or Proportional Control
The VA-7150 series synchronous motor driven actuator provide
control with up to 19mm stroke.
These actuators can be easily installed on site or ordered pre-
fitted to VG7000, VGS800 and VG9000 flanged valve series in
accordance with the specified maximum close-off pressure ratings.
FEATURES
Compact unit for 500N force
Magnetic clutch and unique yoke design
Coupler for simple actuator attachment to flanged valves
Positioner with adjustable starting point and span, reverse and
direct action modes
Signal fail safe position
Ordering Codes
Supply
Voltage
Action
Control
Coupler
Type Force
List
Price
VA-7150-1001 24Vac
Floating
Threaded
500N
123
VA-7150-1003 230Vac 123
VA-7150-8201 24Vac
Slotted
142
VA-7150-8203 230Vac 142
VA-7152-1001 24Vac
Proportional
0-10V
Threaded 161
VA-7152-8201 24Vac Slotted 249
Supply Voltage - 24V or 230V, 50/60Hz
Nominal Stroke - 19mm max.
Size - 153 x 97.5mm
Protection Class - IP40
VA-1000 Series
2000 and 2500N, Floating or
Proportional Control
These valve-actuators are of modular construction so that
the required type of control signal is achieved simply by
fitting a module with the required function in-situ. It can be
mounted onto VG8000 (H, N, V), VG8300N&H and VG9000
series valves.
FEATURES
Manual override and automatic stem coupling
Actuator fixed to valve with one ring nut
Self adjusting, automatic stroke adjustment, calibrated pressure control
at the end positions
Two auxiliary switches, feedback potentiometer and split range unit available
Selectable characteristic curve and running time
230Vac power supply module available
Ordering Codes
Supply
Voltage Force Spring Return *
List
Price
VA-1125-GGA-1
24Vac
2500N None 532
VA-1220-GGA-1
2000N
Retracts 674
VA-1420-GGA-1 Extends 674
* On power failure
ACCESSORIES (for in-situ installation)
Ordering Codes Description Price
VA1000-M230 230Vac Module 39
VA1000-P2 2 K feedback potentiometer 92
VA1000-S2 2 x SPDT auxiliary switches 77
VA1000-SRU Split range unit module for proportional actuators only 54
VA1000-EP Extension kit for applications with temp. 140-200C 79
Nominal Stroke - 49mm
Size - 230 x 136/149 x 263mm
Protection Class - IP66
LINEAR ACTUATORS (cont)
7
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
VA-7700 Series
500N, Floating or Proportional Control
The VA-7700 series are designed for mounting onto
VG7000, VGS800 and VG9000 valves.
FEATURES
Manual override
LED operating status display
Self calibrating
Ordering Codes
Supply
Voltage
Action
Control
Override
List
Price
Manual Electrical
For VG7000 Series Valves
VA-7700-1001
24Vac
Floating
- - 88
VA-7740-1001

- 110
VA-7700-1003
230Vac
- - 131
VA-7740-1003

- 110
VA-7706-1001
24Vac Proportional
-

178
VA-7746-1001

200
For VGS8000 / VG9000 Series Valves
VA-7700-8201
24Vac
Floating
- - 151
VA-7740-8201

- 190
VA-7700-8203
230Vac
- - 151
VA-7740-8203

- 190
VA-7706-8201
24Vac Proportional
-

251
VA-7746-8201

277
Supply Voltage - 24Vac or 230Vac, 50/60Hz
Stroke - 20mm Size - 178 x 159 x 131mm
Full Stroke Time - 190 sec. Protection Class - IP54
VA-7800 Series
1000N, ON/OFF, Floating or Proportional Control
Spring return and non-spring return actuator with 1000N thrust for valves in heating,
ventilation and air-conditioning applications. All models have manual override as
standard. Proportional models are self-calibrating.
This actuator is intended for use with VG7000 and VGS800
threaded valves as well as VG9000, VG8000 (H, N, V) and
VG8300N&H flanged valves.
FEATURES
Proportional actuators are self-calibrating
Force controlled motor shut-off
Manual override as standard and status LED
Models with optional aux. switches or 2 k feedback potentiometer
Control-signal failure - stem to pre-determined position
Stroke position indicator
Ordering Codes
Supply
Voltage
Action
Control
Spring
Return**
2 x Aux.
Switches
2 K
pot.
List
Price
For VG7000 Series Valves
VA-7810-ADA-11
230Vac
ON/OFF
or
Floating
-
-
-
247
VA-7810-ADC-11

323
VA-7810-AGA-11
24Vac
- 246
VA-7810-AGC-11

307
VA-7810-AGH-11 -

307
VA-7810-GGA-11
ON/OFF,
Floating or
Proport.*
-
-
-
333
VA-7810-GGC-11

384
For VGS8000 / VG8000 / VG9000 Series Valves
VA-7810-ADA-12
230Vac
ON/OFF
or
Floating
-
-
-
261
VA-7810-ADC-12

323
VA-7810-AGA-12
24Vac
- 246
VA-7810-AGC-12

307
VA-7810-AGH-12 -

307
VA-7810-GGA-12
ON/OFF,
Floating or
Proport.*
-
-
-
338
VA-7810-GGC-12

384
(Continued next column)
M910x-xGA-xS Series
(Joventa DAB / DAD / DMD)
2 and 4 Nm, Non-Spring Return
ON/OFF, Floating or Proportional Control
The Small Family electric damper actuator series has
been developed to operate small air dampers in
ventilation and air-conditioning systems. The compact
design make this actuator highly versatile.
FEATURES
Load-independent running time
Up to five actuators in parallel operation is possible
Actuators available with PVC cable or with plug-in
terminal block connection
Simple direct mounting with universal adapter
Selectable direction of rotation
Manual release button
Ordering Codes
Control
Signals
Supply
Voltage Connection
List
Price
Johnson Contr. Joventa
2 Nm Actuators
M9102-AGA-1S DAB1.4
Floating
24Vac
Cable 65
M9102-AGA-5S DAB1.4C Terminal 57
M9102-IGA-1S DAB1
ON/OFF or
Floating*
Cable 71
M9102-IGA-5S DAB1C Terminal 75
4 Nm Actuators
M9104-AGA-1S DAD1.4
Floating
24Vac
Cable 64
M9104-AGA-5S DAD1.4C Terminal 57
M9104-IGA-1S DAD1
ON/OFF or
Floating*
Cable 71
M9104-IGA-5S DAD1C Terminal 57
M9104-GGA-1S DMD1.2
Proportional
Cable 121
M9104-GGA-5S DMD1.2C Terminal 118
* With timeout
Supply Voltage - 24Vac, 50/60Hz
Control Signals - ON/OFF, Floating and Proportional 0-10Vdc
Running Time - 36 sec. (2 Nm types), 72 sec. (4 Nm types)
Universal Adapter - for 8-13mm or 8-10mm square shaft. 45mm min. shaft length
Damper Sizes - 0.4 m
2
(2 Nm types), 0.8 m
2
(4 Nm types)
Size - 71 x 52 x 131mm
Protection Class - IP42 (-1S types), IP40 (-5S types)
Rotary Actuators - Silence and Small Family
Ordering Codes
Supply
Voltage
Action
Control
Spring
Return**
2 x Aux.
Switches
2 K
pot.
List
Price
For VG8000 / VGS9000 Series Valves
VA-7820-GGA-11
24Vac
ON/OFF,
Floating or
Proport.*
Retracts
-
-
352
VA-7820-GGC-11

515
VA-7830-GGA-11
Extends
- 360
VA-7830-GGC-11

515
For VGS8000 / VG8000 / VG9000 Series Valves
VA-7820-GGA-12
24Vac
ON/OFF,
Floating or
Proport.*
Retracts
-
-
360
VA-7820-GGC-12

421
VA-7830-GGA-12
Extends
- 358
VA-7830-GGC-12

421
* Full stroke time 150 secs (selectable 75 sec.)
** On power failure
Supply Voltage - 24Vac or 230Vac, 50/60Hz
Stroke - 7-25mm
Auxiliary Switches - 2(1)A, 230V 50/60Hz
Full Stroke Time - 150 sec. (selectable 75 sec. on proportional models)
Cable - 1.5m length
Size - 212 x 115 x 231mm
Protection Class - IP54
LINEAR / ROTARY ACTUATORS
8
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
Ordering Codes
Control
Signals
Supply
Voltage
Feedback
Potentio.
2 x Aux.
Switches
List
Price
Johnson Contr. Joventa*
8 Nm Actuators
M9108-AGA-1N DAS1
ON/OFF
or
Floating
24V
ac/dc
-
- 109
M9108-AGC-1N DAS1.S

101
M9108-AGE-1N DAS1.P1 1 k
-
112
M9108-AGD-1N DAS1.P2 140 176
M9108-AGF-1N DAS1.P4 2 K 143
M9108-ADA-1N DAS2
230Vac
-
80
M9108-ADC-1N DAS2.S

101
M9108-ADE-1N DAS2.P1 1 K
-
176
M9108-ADD-1N DAS2.P2 140 143
M9108-ADF-1N DAS2.P4 2 K 176
M9108-GGA-1N DMS1.1
Proport.
24V
ac/dc
-
- 110
M9108-GGC-1N DMS1.1S

177
M9108-GDA-1N DMS2.2 Proport.
0(2)-10Vdc
230Vac
- 197
M9108-GDC-1N DMS2.2S

149
M9108-GDA-1N1 DMS2.5 Proport.
0(4)-20mA
- 184
M9108-GDC-1N1 DMS2.5S

145
16 Nm Actuators
M9116-AGA-1N DA1
ON/OFF
or
Floating
24V
ac/dc
-
- 126
M9116-AGC-1N DA1.S

110
M9116-AGE-1N DA1.P1 1 k
-
122
M9116-AGD-1N DA1.P2 140 188
M9116-AGF-1N DA1.P4 2 K 188
M9116-ADA-1N DA2
230Vac
-
90
M9116-ADC-1N DA2.S

154
M9116-ADE-1N DA2.P1 1 k
-
126
M9116-ADD-1N DA2.P2 140 167
M9116-ADF-1N DA2.P4 2 K 196
M9116-GGA-1N DM1.1
Proport.
24V
ac/dc
-
- 183
M9116-GGC-1N DM1.1S

158
M9116-GDA-1N DM2.2
Proport.
0(2)-10Vdc
230Vac
- 151
M9116-GDC-1N DM2.2S

173
M9116-GDA-1N1 DM2.5
Proport.
0(4)-20mA
- 253
M9116-GDC-1N1 DM2.5S

291
24 Nm Actuators
M9124-AGA-1N DAL1
ON/OFF
or
Floating
24V
ac/dc
-
- 137
M9124-AGC-1N DAL1.S

160
M9124-AGE-1N DAL1.P1 1 k
-
291
M9124-AGD-1N DAL1.P2 140 291
M9124-AGF-1N DAL1.P4 2 K 291
M9124-ADA-1N DAL2
230Vac
-
142
M9124-ADC-1N DAL2.S

158
M9124-ADE-1N DAL2.P1 1 K
-
299
M9124-ADD-1N DAL2.P2 140 299
M9124-ADF-1N DAL2.P4 2 K 299
M9124-GGA-1N DML1.1
Proport.
24V
ac/dc
-
- 182
M9124-GGC-1N DML1.1S

233
M9124-GDA-1N DML2.2
Proport.
0(2)-10Vdc
- 270
M9124-GDC-1N DML2.2S
230Vac

317
M9124-GDA-1N1 DML2.5
Proport.
0(4)-20mA
- 330
M9124-GDC-1N1 DML2.5S

364
32 Nm Actuators
M9132-AGA-1N DAG1
ON/OFF
or
Floating
24V
ac/dc
-
- 212
M9132-AGC-1N DAG1.S

223
M9132-AGE-1N DAG1.P1 1 k
-
291
M9132-AGD-1N DAG1.P2 140 291
M9132-AGF-1N DAG1.P4 2 K 291
M9132-ADA-1N DAG2
230Vac
-
151
M9132-ADC-1N DAG2.S

235
M9132-ADE-1N DAG2.P1 1 K
-
299
M9132-ADD-1N DAG2.P2 140 299
M9132-ADF-1N DAG2.P4 2 K 299
M9132-GGA-1N DMG1.1
Proport.
**
24V
ac/dc
-
- 292
M9132-GGC-1N DMG1.1S

311
* Add K after code for Halogene free cable (1m) (Continued next column)
M91xx-xxx-1N(1) Series
(Joventa DAS-DMS / DA-DM / DAL-DML / DAG-DMG)
8, 16, 24 and 32 Nm, Non-Spring Return
ON/OFF, Floating or Proportional Control
The Standard Electric actuators have been specially designed for use with
small and medium-sized air dampers and for terminal control units.
The very small size and clever construction make them ideal for
applications where space is limited. A key feature of the design is
the special spindle adapter which also incorporates angle-of-
rotation limiting and position indication.
FEATURES
Load independent running time
Paralleling of up to five actuators is possible
Simple direct-mount with universal adapter
Angle-of-rotation limiting and manual control
by pushbutton
Two auxiliary switches
(Continued next column)
Rotary Actuators - Standard Family
M9304-xxx-1N Series
(Joventa DAN / DAN2 / DMN)
4 Nm, Non-Spring Return
ON/OFF, Floating or Proportional Control
The Silence Electric damper actuator series has been developed
to operate small and medium air dampers in ventilation and air-
conditioning systems. The compact design and universal adapter
fitted with limitation of rotation angle make this actuator
highly versatile.
A key feature of the design is the stem adapter which also incorporates
angle-of-rotation limiting and position indication.
FEATURES
Load-independent running time
Up to five actuators in parallel operation is possible
Simple direct mounting with universal adapter
Selectable direction of rotation and limitation of rotation angle
Manual release button
Automatic shut-off at end position (overload switch)
Ordering Codes
Control
Signals
Supply
Voltage
2 x Aux.
Switches**
List
Price
Johnson Contr. Joventa*
4 Nm Actuators
M9304-AGA-1N DAN1N
ON/OFF or
Floating
24Vac/dc
- 62
M9304-AGC-1N DAN1.SN
74
M9304-ADA-1N DAN2N
230Vac
- 63
M9304-ADC-1N DAN2.SN
75
M9304-AKA-1N DAN5N
48Vdc
- 90
M9304-AKC-1N DAN5.SN
139
M9304-BDA-1N DAN2.C
230Vac
- 98
M9304-BDC-1N DAN2.SC
126
M9304-GGA-1N DMN1.2N
Proportional
24Vac/dc
-
90
M9304-GKA-1N DMN5.2N 48Vac/dc 164
* Add K after order code for Halogene free cable (1m)
** Adjustable auxiliary contacts
Supply Voltage - 24Vac/dc, 230Vac, 48Vac/dc, 50/60Hz
Control Signals - ON/OFF, Floating or Proportional 0-10Vdc
Running Time - 35 sec.
Auxiliary Switches - 3(1.5)A, 230V 50/60Hz
Universal Adapter - for 6-16mm or 8-10mm square shaft or with M9000-Z01DN
adapter kit for 8, 10, 11 and 12mm square shaft. Min. damper shaft of 45mm length.
Damper Size - 0.8 m
2
Size - 85 x 65 x 166mm
Protection Class - IP50
ROTARY ACTUATORS (cont)
9
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
Rotary Actuators - Spring Return Family
M9206-xxx-1S Series
(Joventa DBF1.06 / DAFx.06 / DMF1.06)
6 Nm, Spring Return
ON/OFF, Floating or Proportional
This Spring Return electric damper actuator series has been
specially developed for the operation of safety air dampers
(anti-icing) in air-conditioning systems, smoke evacuation
dampers and sealing dampers.
The compact design and universal adapter fitted with limitation
of rotation angle make this actuator highly versatile.
FEATURES
Electrical connections with halogen-free cable
Up to five actuators in parallel operation is possible
Simple direct-mount with universal adapter
Selectable direction of rotation
Limitation of rotation angle and adjustable auxiliary switch
Automatic shut-off at end position (overload switch)
Ordering Codes
Control
Signals
Supply
Voltage
1 x Aux.
Switch
Running Time
List
Price
Johnson Contr. Joventa* Motor (Spring)
6 Nm Actuators
M9206-AGA-1 DBF1.06
ON/OFF
or
Floating
24V
ac/dc
-
60-90s
(35-90s)
199
M9206-AGB-1 DBF1.06S

239
M9206-BGA-1S DAF1.06
ON/OFF
24Vac
-
10-40s
(35-70s)
173
M9206-BGB-1S DAF1.06S

186
M9206-BDA-1S DAF2.06
230Vac
-
10-65s
(35-70s)
203
M9206-BDB-1S DAF2.06S

216
M9206-GGA-1 DMF1.06
Proport.
24V
ac/dc
-
25-40s
(35-90s)
250
M9206-GGB-1 DMF1.06S

272
* Add K after order code for Halogene free cable (1 m)
Control Signals - ON/OFF, Floating or Proportional 0(2)-10Vdc, 0(4)-20mA
Auxiliary Switch - (adjustable)
Universal Adapter - 10-16mm shaft or 10-14mm square shaft. Min. damper shaft of
45mm length
Damper Size - 1.1m
2
Connection - Plug-in terminal block (only for Bxx models)
Size - 178 x 83 x 75mm
Protection Class - IP42
Control Signals - ON/OFF, Floating or Proportional 0(2)-10Vdc, 0(4)-20mA
Running Time - 30 sec. (8 Nm types), 80 sec. (16 Nm types), 125 sec. (24 Nm types),
140 sec. and 200 sec.** (32 Nm types)
Auxiliary Switch - 3(1.5)A, 230V 50/60Hz
Universal Adapter - for 10-20mm or 10-16mm square spindle. Min. damper shaft of
45mm length.
Damper Size - 1.5m
2
(8 Nm types), 3m
2
(16 Nm types), 4.5m
2
(24 Nm types),
6m
2
(32 Nm types)
Connections - Terminal screw
Size - 68 x 100 x 180mm
Protection Class - IP54
M9208-xxx-1 Series
(Joventa DBF1.08 / DAFx.08 / DMF1.08)
8 Nm, Spring Return
ON/OFF, Floating or Proportional Control
This new range of electric damper-actuators has been specially
developed for the motorised operation of air dampers in air-
conditioning systems.
Manual operation is automatically cancelled when the actuator is in
electrical operation. The compact design and universal adapter, fitted
with limitation of rotation angle, makes this actuator highly versatile.
FEATURES
Up to five actuators in parallel operation is possible
Electrical connection with halogen-free cable
Simple direct mounting with universal adapter
Limitation of rotation angle
Manual positioning with crank handle
Two auxiliary switches (one adjustable) with Gold Flash contacts
Ordering Codes
Control
Signals
2 x Aux.*
Switches
Supply
Voltage
Running Time
List
Price
Johnson Contr. Joventa Motor (Spring)
8 Nm Actuators
M9208-AGA-1 DBF1.08N
ON/OFF or
Floating
-
24Vac/dc
150s
(17-25s)
268
M9208-AGC-1 DBF1.08SN

304
M9208-BGA-1 DAF1.08N
ON/OFF
-
230Vac
55-71s
(13-26s)
214
M9208-BGC-1 DAF1.08SN

250
M9208-BDA-1 DAF2.08N -
24Vac/dc
55-71s
(13-26s)
232
M9208-BDC-1 DAF2.08SN

268
M9208-GGA-1 DMF1.08N
Proport.
**
-
24Vac/dc
150s
(17-25s)
302
M9208-GGC-1 DMF1.08SN

334
* Includes one adjustable auxiliary switch
** Direct or reverse action with signal increase (switch selectable)
Supply Voltage - 24Vac/dc, 230Vac, 50/60 Hz
Control Signals - ON/OFF, Floating or Proportional 0(2)-10V, 0(4)-20mA
Rotation Range - 95 max. full stroke (adjustable 35-95)
Universal Adapter - 8-16mm round shafts or 6-12mm square shafts. Optional
Jackshaft Coupler Kit (M9208-600) for 12-19mm or 10-14mm square shafts
Auxiliary Switches - 2 x SPDT 240Vac, 5A and 24Vac, 50VA
Size - 161 x 99 x 58mm
Protection Class - IP54
ACCESSORIES AND REPLACEMENT PARTS
Order. Codes Description Price
M9000-604
Replacement Anti-Rotation Bracket Kit for M9208,
M9210 and M9220 series actuators
14
M9208-100
Remote Mounting Kit, including mounting bracket,
M9208-150 crankarm, ball joint and mounting fastener
1
M9208-150 Crankarm 1
M9208-600
Large Shaft Coupler Kit (with locking clip) for mounting
M9208-xxx-1 series actuators on dampers with 12-
19mm or 10-14mm square shafts
1
M9208-601
Replacement Standard Coupler Kit (with locking clip)
for mounting M9208-xxx-1 series on dampers with
8-16mm or 6-12mm square shafts
1
M9208-602
Replacement Locking Clips for M9208-xxx-1 series
actuators (quantity 5)
1
M9208-603 Adjustable Stop Kit for M9208-xxx-1 series actuators 1
M9208-604
Replacement Manual Override Cranks for M9208
series electric actuators with long crank radius: 72mm
(quantity 5)
1
M9208-605
Replacement Manual Override Cranks for M9208 series
actuators with short crank radius: 46.5mm (quantity 5)
1
10
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
M9216-xxx-1 Series
(Joventa DA1.4F / DA1.F-DA2.F / DM1.1F)
16 Nm, Spring Return
ON/OFF, Floating or Proportional Control
This spring-return damper actuator has been specially developed
for the operation of safety (anti-icing) air dampers in air-
conditioning systems, smoke evacuation and sealing dampers.
When the control signal is applied the actuator drives the damper
to the operational position while evenly tensioning the integrated
spring. After a power failure the spring immediately brings the
damper to the safe position. Manual operation is automatically
cancelled when the actuator is in electrical operation.
FEATURES
Up to five actuator in parallel operation is possible
Universal adapter
Low noise level
Direction of rotation selection an angle-of-rotation limiting
Manual control by pushbutton
Two floating auxiliary switches
Ordering Codes
Control
Signals
Supply
Voltage
2 x Aux.
Switches
Feedback
Potentio.
List
Price
Johnson Contr. Joventa*
16 Nm Actuators
M9216-AGA-1 DA1.4F
Floating
24V
ac/dc
-
-
200
M9216-AGC-1 DA1.4FS

215
M9216-AGE-1 DA1.4FP1
-
1 k 359
M9216-AGD-1 DA1.4FP2 140 k 359
M9216-BGA-1 DA1.F
ON/OFF
24V
ac/dc
-
-
172
M9216-BGC-1 DA1.FS

184
M9216-BDA-1 DA2.F
230Vac
- 187
M9216-BDC-1 DA2.FS

200
M9216-HGA-1 DM1.1F
Proport.
24V
ac/dc
-
-
301
M9216-HGC-1 DM1.1FS

321
* Add K after order code for Halogene free cable (1m)
Supply Voltage - 24Vac/dc, 230Vac, 50/60Hz
Control Signals - ON/OFF, Floating or Proportional 0-10Vdc, 0-20mA
Running Time - Floating and ON/OFF Control: 90-120 sec. (motor), 10 sec. (spring)
- Proportional Control: 90 sec. (motor), 10 sec. (spring)
Auxiliary Switches - 3(1.5)A, 230V 50/60Hz
Universal Adapter - 10-20mm round shafts and 10-16mm square shafts
Damper Size - 3.0m
2
Connections - Screw terminal
Size - 250 x 116 x 88mm
Protection Class - IP54
Order. Codes Description Price
M9000-604
Replacement Anti-rotation Bracket Kit (with screws) - for
M9220-xxx-3 series actuators
6
M9220-600
25mm Jackshaft Coupler Kit (with Locking Clip) - for
mounting M9220-xxx-3 Series actuators on dampers with
19-27mm, or 16, 18 and 19mm square shafts
6
M9220-601
Replacement Coupler Kit (with Locking Clip) - for
mounting M9220-xxx-3 series actuators on damper with
12-19mm, or 10, 12 and 14mm square shafts
13
M9220-602
Replacement Locking Clips for M9220-xxx-3 series
actuators (5 per bag)
6
M9220-603
Adjustable Stop Kit - for M9220-xxx-3 series spring
return actuators
10
M9220-604
Replacement Manual Override Cranks - for M9220-xxx-3
series actuators (5 per bag)
6
M9220-610
Replacement Shaft Gripper - 10mm square shaft with
locking clip
8
M9220-612
Replacement Shaft Gripper - 12mm square shaft with
locking clip
7
M9220-614
Replacement Shaft Gripper - 14mm square shaft with
locking clip
8
* Furnished with the damper and may be ordered separately.
M92x0-xxx1 Series
(Joventa DAFx.10 / DBF1.10 / DMF1.10)
10, 20 Nm, Spring Return
ON/OFF, Floating or Proportional Control
These actuators are direct mount, spring return, providing reliable
control of dampers and valves. These bi-directional actuators do
not require a damper linkage and are easily installed on dampers.
FEATURES
Two or three models mounted in tandem deliver twice or
triple the torque
Up to five actuators in parallel operation is possible
Optional adjustable end stops.
Integrated cables halogen-free cables
Rated aluminium enclosure
Easy-to-use locking manual override with auto release and crank storage
Two Integral Gold auxiliary switches (xxC models)
Ordering Codes
Control
Signals
Supply
Voltage
2 x Aux.
Switches
Running Time
List
Price
Johnson Contr. Joventa* Motor (Spring)
10 Nm Actuators
M9210-AGA-1 DBF1.10
ON/OFF or
Floating
24V
ac/dc
-
150s
(20s)
292
M9210-AGC-1 DBF1.10S

325
M9210-BDA-1 DAF2.10
ON/OFF
230Vac
-
25-57s
(11-15s)
260
M9210-BDC-1 DAF2.10S

303
M9210-BGA-1 DAF1.10
24V
ac/dc
- 229
M9210-BGC-1 DAF1.10S

233
M9210-GGA-1 DMF1.10
Proport.
24V
ac/dc
-
150s
(26s)
302
M9210-GGC-1 DMF1.10S

334
M9210-HGA-1 DHF1.10
Proport.
**
- 309
M9210-HGC-1 DHF1.10S

326
20 Nm Actuators
M9220-AGA-1 DBF1.20
ON/OFF or
Floating
24V
ac/dc
-
150s
(20s)
293
M9220-AGC-1 DBF1.20S

336
M9220-BDA-1 DAF2.20
ON/OFF
230Vac
-
25-57s
(11-15s)
262
M9220-BDC-1 DAF2.20S

309
M9220-BGA-1 DAF1.20
24V
ac/dc
- 235
M9220-BGC-1 DAF1.20S

280
M9220-GGA-1 DMF1.20
Proport.
24V
ac/dc
-
150s
(26s)
301
M9220-GGC-1 DMF1.20S

334
M9220-HGA-1 DHF1.20
Proport.
**
- 309
M9220-HGC-1 DHF1.20S

334
* Add K after order code for Halogene free cable (1m)
** With span offset
Supply Voltage - 24Vac/dc, 230Vac, 50/60Hz
Control Signals - ON/OFF, Floating or Proportional 0(2)-10Vdc
Auxiliary Switches - 3(1.5)A, 230V 50/60Hz
Damper Size - 2.0m
2
(All 10Nm types and 20Nm - ON/OFF or Floating types),
4.0m
2
(20Nm - ON/OFF and Proportional types)
Size - 262 x 102 x 84mm
Protection Class - IP54 (NEMA2)
ACCESSORIES AND REPLACEMENT PARTS
Order. Codes Description Price
DMPR-KC003*
178 mm Blade Pin Extension (without Bracket) for direct
mount damper applications
POA
M9000-158
Tandem Mounting Kit - to mount two models of
M9220-xxx-3 series actuators
61
M9000-153 Crank Arm 1
M9000-170
Remote Mounting Kit, Horizontal - includes mounting
bracket, M9000-153 crank arm, ball joint and mounting bolts
65
M9000-171
Remote Mounting Kit, Vertical - includes mounting bracket,
M9000-153 crank arm, ball joint and mounting bolts
65
M9000-200
Commissioning Tool - provides control signal to drive 24V
floating, floating, proportional and/or resistive electric actuators
822
(Continued next column)
ROTARY ACTUATORS (cont)
11
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
M91xx-xxx-1N4 Series
(Joventa SAx.1xxx / SM1.1x)
8 and 16 Nm,
ON/OFF, Floating or
Proportional Control
The Special Electric actuators have been specially
designed for use with small and medium-sized air dampers
and for terminal control units in air volume control systems.
The very small size and clever construction make these ideal for applications where
space is limited. A key feature of the design is the special spindle adapter which also
incorporates angle-of-rotation limiting and position indication.
FEATURES
Paralleling of up to five actuators is possible
Universal adapter
Choice of rotation
Angle-of-rotation limiting
Manual control by pushbutton
Ordering Codes
Control
Signals
2 x Aux.
Switches
Feedback
Potentio.
Supply
Voltage
List
Price
Johnson Contr. Joventa*
8 Nm Actuators
M9108-AGA-1N4 SA1.10
ON/OFF
or
Floating
-
-
24V
ac/dc
173
M9108-AGC-1N4 SA1.10S

205
M9108-AGE-1N4 SA1.10P1
-
1 k 218
M9108-AGD-1N4 SA1.10P2 140 218
M9108-AGF-1N4 SA1.10P4 2 K 218
M9108-ADA-1N4 SA2.10
-
230Vac
186
M9108-ADC-1N4 SA2.10S

218
M9108-ADE-1N4 SA2.10P1
-
1 k 231
M9108-ADD-1N4 SA2.10P2 140 231
M9108-ADF-1N4 SA2.10P4 2 k 231
M9108-GGA-1N4 SM1.10
Proport.
-
-
24V
ac/dc
247
M9108-GGC-1N4 SM1.10S

279
16 Nm Actuators
M9116-AGA-1N4 SA1.12
ON/OFF
or
Floating
-
-
24V
ac/dc
173
M9116-AGC-1N4 SA1.12S

189
M9116-AGE-1N4 SA1.12P1
-
1 k 218
M9116-AGD-1N4 SA1.12P2 140 218
M9116-AGF-1N4 SA1.12P4 2 K 218
M9116-ADA-1N4 SA2.12
-
230Vac
186
M9116-ADC-1N4 SA2.12S

218
M9116-ADE-1N4 SA2.12P1
-
1 k 231
M9116-ADD-1N4 SA2.12P2 140 231
M9116-ADF-1N4 SA2.12P4 2 K 231
M9116-GGA-1N4 SM1.12
Proport.
-
-
24V
ac/dc
247
M9116-GGC-1N4 SM1.12S

279
*Add K after order code for Halogene free cable (1m)
Supply Voltage - 24Vac/dc, 230Vac, 50/60Hz
Control Signals - ON/OFF, Floating or Proportional 0(2)-10Vdc, 0(4)-20mA
Running Time - 8 sec. (8 Nm types), 16 sec. (16 Nm types)
Auxiliary Switches - 3(1.5)A, 230V 50/60Hz
Universal Adapter - 10-20mm shafts or 10-16mm square shafts with
Z01DN- adapter. Minimum shaft length 48mm.
Connections - Screw terminal
Damper Size - 1.5m
2
(8 Nm types), 3.0m
2
(16 Nm types)
Size - 195 x 100 x 68mm
Protection Class - IP54
Rotary Actuators - Special and Security Family
M91xx-GAx-1.01 Series
(Joventa SMxx.5)
8 Nm, Proportional Control
(110Vac supply)
The Special Electric actuators have been specially
designed for use with medium and large air dampers.
The very small size and clever construction make them
ideal for applications where space is limited. A key feature of the design
is the special spindle adapter which also incorporates angle-of-rotation
limiting and position indication.
FEATURES
Paralleling of up to five actuators is possible
Universal adapter
Choice of rotation and angle-of-rotation limiting
Manual control by pushbutton
Two floating auxiliary switches
Ordering Codes
Control
Signal
Supply
Voltage
2 x Aux.
Switches
List
Price
Johnson Contr. Joventa
8 Nm Actuators
M9108-GAA-1.01 SMS4.5
Proportional 110Vac
- 219
M9108-GAC-1.01 SMS4.5S

190
* Add K after order code for Halogene free cable (1m)
Note: 16 and 24Nm actuators are available on request.
Supply Voltage - 110Vac, 50/60Hz
Control Signal - Proportional 0(4)-20mA
Auxiliary Switch - 3(1.5)A, 230V 50/60Hz
Running Time - 30-45 sec.
Damper Size - 1.5m
2

Universal Adapter - 10-20mm shafts and 10-16mm square shafts. Minimum shaft
length 48mm.
Connection - Screw terminal
Size - 195 x 100 x 68mm
Protection Class - IP54
M9116-Axx-1 Series
(Joventa SAx.30)
16 Nm, ON/OFF or Floating Control
(100Vac Supply)
The Special Electric actuators have been specially
designed for use with medium and large air dampers.
The very small size and clever construction make them ideal
for applications where space is limited. A key feature of the design is
the special spindle adapter which also incorporates angle-of-rotation
limiting and position indication.
FEATURES
Paralleling of up to five actuators is possible
Universal adapter
Low noise level
Choice of rotation and angle-of-rotation limiting
Manual control by pushbutton
Two floating auxiliary switches
Ordering Codes
Control
Signals
Supply
Voltage
2 x Aux.
Switches
List
Price
Johnson Contr. Joventa*
16 Nm Actuators
M9116-AAA-1 SA4.30
ON/OFF or
Floating
100Vac
- 171
M9116-AAC-1 SA4.30S

206
Note: * Add K after order code for Halogene free cable (1m)
Supply Voltage - 100Vac, 50/60Hz
Running Time - 80-110 sec.
Auxiliary Switches - 3(1.5)A, 230V 50/60Hz
Damper Size - 3.0m
2
Universal Adapter - 10-20mm shafts and 10-16mm square shafts. Minimum shaft
length 48mm.
Connection - Screw terminal
Size - 195 x 100 x 68mm
Protection Class - IP54
12
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
VA9104-xGA-xS Series

(Joventa BAD1.4 / BAD1 / BMD1.2)
4 Nm Actuators
ON/OFF, Floating or
Proportional Control
This series of actuators has been developed for
operation of ball valves.
These synchronous, motor driven actuators are used
to provide accurate positioning on VG1000 series
DN15, DN20 and DN25 ball valves.
FEATURES
Load-independent running time
Up to five actuators in parallel operation possible
Manual release button
Selectable direction of rotation
Automathic shut-off at end position
Ordering Codes
Control
Signals
Supply
Voltage Connection
List
Price
Johnson Contr. Joventa
4 Nm Actuators
VA9104-AGA-1S BAD1.4
Floating
24Vac
Cable 94
VA9104-AGA-5S BAD1.4C Terminal 83
VA9104-IGA-1S BAD1
ON/OFF or
Floating*
Cable 113
VA9104-IGA-5S BAD1C Terminal 105
VA9104-GGA-1S BMD1.2
Proportional
Cable 143
VA9104-GGA-5S BMD1.2C Terminal 139
* With timeout
Supply Voltage - 24Vac, 50/60Hz
Control Signal - ON/OFF, Floating or Proportional 0(2)-10Vdc, 0(4)-20mA
Running Time - 72 sec.
Connection - PVC cable (1.2m) or terminal block
Size - 67 x 140 x 71mm
Protection Class - IP42 (-1S types), IP40 (-5S types)
Rotary Actuators - Valve Family
M9108-xxx-5 Series
(Joventa BAS1 / BAS2 / BMS1.1)
8 Nm Actuators
ON/OFF, Floating or Proportional
This series has been developed for operating
VG1000 series ball valves.
The actuators can be mounted onto the valves by the
means of the M9000-525-5 linkage kit.
FEATURES
Halogen-free connecting wire
Load-independent running time
Easy assembly on the console
Selectable direction of rotation
Manual adjustment by pushing the release button and turning the handle
with position indicator (the release button does not automatically spring
back into position)
Automatic switching off in the limit positions
Ordering Codes
Control
Signals
Supply
Voltage
2 x Aux.
Switches
List
Price
Johnson Contr. Joventa
8 Nm Actuators
M9108-AGA-5 BAS1
ON/OFF
or
Floating
24Vac/dc
- 134
M9108-AGC-5 BAS1.S

169
M9108-ADA-5 BAS2
230Vac
- 134
M9108-ADC-5 BAS2.S

169
M9108-GGA-5 BMS1.1
Proportional 24Vac/dc
- 158
M9108-GGC-5 BMS1.1S

192
(Continued next column)
M9116-xxx-1N2 Series
(Joventa MA1 / MA2 / MM1.1 / MM2.2)
16 Nm Actuators
ON/OFF, Floating or
Proportional Control
These actuators have been specially designed
for the operation of various types of water valves,
mixing valves, butterfly valves and ball valves. They can
be used on many different types of valves and fittings with
the right mounting kit or coupling.
The universal coupling between the actuator and the final controlling element
is very simple and provides both; a positive drive and flexibility.
FEATURES
Load independent running time
Universal adapter with knob for manual operation and position indication
Reversible
Automatic end stops
Ordering Codes
Control
Signals
Supply
Voltage
2 x Aux.
Switches
List
Price
Johnson Contr. Joventa
16 Nm Actuators
M9116-AGA-1N2 MA1
ON/OFF
or
Floating
24Vac/dc
- 176
M9116-AGC-1N2 MA1.S

207
M9116-ADA-1N2 MA2
230Vac
- 188
M9116-ADC-1N2 MA2.S

219
M9116-GGA-1N2 MM1.1
Proportional * 24Vac/dc
- 253
M9116-GGC-1N2 MM1.1S

286
M9116-GDA-1N2 MM2.2
Proportional ** 230Vac
- 288
M9116-GDC-1N2 MM2.2S

320
* Proportional 0(2)-10Vdc, 0-20mA
** Proportional 0(2)-10Vdc, 0-10Vdc
Note: Add K after order code for Halogene free cable (1m)
Supply Voltage - 24ac/dc, 230Vac, 50/60 Hz
Running Time - 120 sec.
Auxiliary Switches - 3(1.5)A, 230V 50/60Hz
Size - 180 x 100 x 67.5mm
Protection Class - IP54
M9206-xxx-5S Series
(DBF1.06 / DAFx.06 / DMF1.06)
6 Nm, Spring Return
ON/OFF, Floating or Proportional Control
These actuators are direct-mount, bi-directional actuators are
designed to be mounted onto VG1000 series forged brass ball
valves using the M9000-520-5 linkage kit. Position feedback is
provided on proportional control models through a proportional
dc voltage signal.
FEATURES
Automatic stroke calibration at installation
Reversible mounting design
Electronic stall detection throughout entire rotation range
Removable coupler
Integral auxiliary switch (xxB models)
(Continued next column)
ACCESSORY
Ordering Code Description Price
M9000-525-5 Linkage kit for mounting VG1000 series ball valves 27
Supply Voltage - 24ac/dc, 230Vac, 50/60Hz
Running Time - 30 sec.
Auxiliary Switches - SPDT
Size - 180 x 100 x 67.5mm
Protection Class - IP54
ROTARY ACTUATORS (cont)
13
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
Ordering
Codes
Range
(bar)
Thread
Size

Style
Capillary
Length (mm) Notes
List
Price
Angled Style - Screwed (ISO 228)
V46AA-9600
5-18
3/8
13
75
- 95
V46AA-9608* A 120
V46AA-9602* 100 B, C 124
V46AA-9950
34
75
B, D 115
V46AA-9951* E, D 96
V46AB-9600
1/2
13 - 101
V46AB-9950 34 D, F 107
V46AC-9600
3/4
13 - 110
V46AC-9951 34 D 152
V46AA-9300
5-23
3/8
5 -
- 81
V46AA-9301* B, G, A 90
V46AA-9606
13
75
B,G 127
V46AA-9609* B, G, A 120
V46AA-9510 50 G 114
V46AB-9300
1/2
5 - - 90
V46AB-9605 13
75
B, G 112
V46AB-9951 34 D, G 133
V46AB-9510 50 G 85
V46AC-9300
3/4
5 - 152
V46AC-9605 13 B, G 135
V46AC-9510 50 G 117
Straight Style - Screwed (ISO 7-RC)
V46AD-9300
5-18
1
5 -
-
283
V46AD-9510 50
75
190
V46AD-9600 13 255
V46AE-9300
1 1/4
5 - 376
V46AE-9510 50
75
275
V46AE-9600 13 300
V46AD-9511
10-23
1
50 75 G
302
V46AE-9512 1 1/4 360
See page 42 for Style references
* Bulk packs on request
Ordering
Codes
Range
(bar)
Flange
Size

Style
Capillary
Length (mm) Notes
List
Price
Straight Style - Flanged (DIN 2533)
V46AR-9300
5-18 1 1/2
5 -
-
454
V46AR-9600 13 75 472
V46AS-9300 5-11.5
2
5 -
836
V46AS-9301 11-18 853
V46AT-9300 5-11.5
2 1/2
1,409
V46AT-9301 11-18 1,181
ACCESSORY
Ordering Code Description Price
KIT031N600 Kit for changing Style 13 into Style 45A 86
Notes:
A = With special washer to prevent waterhammer at low flow capacity
B = Nickel plated seat
C = Longer capillary
D = Solder connection
E = 0.040 i.d.cap.
F = 0.062 i.d.cap.
G = High Range
H = For ammonia applications
MARITIME versions and other specifications are available on request. Please contact
the Sales Support Team.
Ordering Codes
Control
Signals
1 x Aux.
Switch
Supply
Voltage
List
Price
Johnson Contr. Joventa
6 Nm Actuator Types
M9206-AGA-5S DBF1.06
ON/OFF or
Floating
-
24Vac/dc
216
M9206-AGB-5S DBF1.06S

262
M9206-BDA-5S DAF1.06
ON/OFF
-
230Vac
208
M9206-BDB-5S DAF1.06S

246
M9206-BGA-5S DAF2.06 -
24Vac
185
M9206-BGB-5S DAF2.06S

223
M9206-GGA-5S DMF1.06
Proportional *
-
24Vac/dc
261
M9206-GGB-5S DMF1.06S

292
Note: *Proportional 0(2)-10Vdc, 0-10Vdc, 0(4)-20mA input signal requires field
furnished 500 resistor.
Supply Voltage - 24Vac/dc, 230Vac, 50/60Hz
Running Time - 60-90 sec. (on/off & floating types), 10-40 sec. (on/off types),
25-40 sec. (proportional types)
Size - 178 x 83 x 75mm
Protection Class - IP42
ACCESSORY
Ordering Code Description Price
M9000-525-5 Linkage kit for mounting to VG1000 series ball valves 27
VALVES
Angled Style
(Screwed)
Straight Style
(Screwed)
Straight Style
(Flanged)
Modulating Water Valves
V46 Series
Two-way, Pressure Actuated
These pressure actuated modulating valves control the quantity of water to a
condenser by directly sensing pressure changes in a refrigerant circuit.
The valves can be used in non-corrosive refrigerant systems. Ammonia power
elements and valves designed for salt-water applications are available. They also have
a quick opening characteristic and open on pressure increase (direct acting). Reverse
acting (close on pressure increase) is possible.
FEATURES
Pressure balanced valve design
High refrigerant pressure resistant bellows
3/8, 1/2, 3/4 are angled body type valves with high Kv value
3/8 up to 2 pressure valves all range types
Quick opening valve characteristics
No close fitting or sliding parts in water passages
Easy to disassemble. All parts can be replaced
Special bronze bodies and monel parts
Power elements with stainless steel bellows available
Nickel plated seats available for 3/8, 1/2, and 3/4 valves
Direct/reverse action
(Continued next column)
14
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
Angled Style
(Screwed)
Straight Style
(Screwed)
Straight Style
(Flanged)
V47 Series
Temperature Actuated
These modulating water valves can be used for heating applications. It does have an
heating element which means that the bulb temperature always must be higher than
the valve body (power element).
The valve opens at increasing bulb temperature. The bulb must be mounted pointing
downwards up to horizontal.
FEATURES
Pressure balanced valve design
3/8, 1/2, 3/4 are angled body type valves with high Kv value
Quick opening valve characteristics
No close fitting or sliding parts in water passages
Easy to disassemble. All parts can be replaced
Special bronze bodies
Ordering
Codes
Range
(C)
Thread
Size
Capillary
Length
Bulb Style
(Length)
List
Price
Angled Valves - Screwed (ISO 228)
V47AA-9161 46-82 3/8
1.8 m plain Style 4 (82mm)
240
V47AB-9160
24-57
1/2 222
V47AC-9160 3/4 242
Straight Valves - Screwed (ISO 7-RC)
V47AD-9160 24-57
1
1.8 m
armoured
Style 4 (152mm)
329
V47AD-9161 46-82 347
V47AE-9160 24-57
1 1/4
532
V47AE-9161 46-82 640
Straight Valves - Flanged (DIN 2533)
V47AR-9160 24-57
1 1/2
1.8 m
armoured
Style 4 (152mm)
666
V47AR-9161 46-82 851
See page 42 for Style references
V46SA Series
Pressure Actuated, Low Flow
The V46SA is a direct acting, all range, pressure actuated
modulating valve, used to control the water flow to a condenser
by directly sensing pressure changes in a non-corrosive
refrigerant circuit.
The valve is specially designed for use on equipment requiring a
low condenser waterflow such as icemakers, small heat pumps and
water coolers. The spring housing and power element are rolled to
the valve body. Rubber diaphragms seal the water away from the range
spring and bellows part so these are not submerged in water where they
would be subject to sedimentation and corrosion.
FEATURES
Valve designed for low flow
All range power element and spring housing
Small dimensions
Pressure actuated
Various pressure connection style
High refrigerant pressure resistant bellows
Ordering
Codes
Range
(bar)
Thread
Size

Style
Capillary
Length (mm) Notes
List
Price
Straight Style - Screwed (ISO 228)
V46SA-9101
5-23 3/8
45A
750
A 109
V46SA-9110 50 B 65
V46SA-9300 5 - - 64
V46SA-9600 13
750
B 68
V46SA-9950
34
- 68
V46SA-9951 A 114
See page 42 for Style references
Notes:
A = Capillary soldered to power element
B = Capillary separate
Size - 109 x 24 x 51mm
VALVES (cont)
15
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
V5000 Series
DN10-20, PN16
These valves are primarily designed to regulate the flow of water
and steam in response to the demand of a controller in zone
and terminal unit applications.
Following actuators are available:
VA-7047 and VA-7048 Thermal ON/OFF Actuators
VA-7067 Thermal 0-10Vdc Actuators
VA-747x Floating and Proportional Actuators
FEATURES
Forged brass body, stainless steel stem and spring
Inherent flow characteristic: equal percentage
Rangeability 50:1
Ordering
Codes Connection
Body
Size
Kvs
(Control)
Kvs
(By-pass)
Close-off
(kPa)
List
Price
2-way PDTC (Normally Open) Configuration
V5210ZC
BSP
DN10
0.16
- 400
25
V5210BC 0.4 25
V5210CC 0.63 25
V5210DC 1 25
V5210EC 1.6 25
V5210JC
DN15
2.5
- 110
25
V5210KC 3.5 28
V5210MC DN20 4.5 45
V5290ZC
Compression
**
DN10
0.16
- 400
25
V5290BC 0.4 25
V5290CC 0.63 25
V5290DC 1 25
V5290EC 1.6 25
3-way Mixing/Diverting Configuration
V5810BC
BSP
DN10
0.4 0.3
120
34
V5810CC 0.63 0.4 34
V5810DC 1 0.63 34
V5810EC 1.6 1 34
V5810JC
DN15
2.5 1.6
150
37
V5810KC 4 2.5 37
V5810MC DN20 5 3.5 110 46
3-way Mixing/Diverting with Built-in Bypass Configuration
V5510BC
BSP
DN10
0.4 0.3
180
37
V5510CC 0.63 0.4 37
V5510DC 1 0.63 37
V5510EC 1.6 1 37
V5510JC
DN15
2.5 1.6
150
43
V5510KC 4 2.5 43
V5510MC DN20 5 3.5 110 52
V5590BC
Compression
**
DN10
0.4 0.3
180
37
V5590CC 0.63 0.4 37
V5590DC 1 0.63 37
V5590EC 1.6 1 43
Note: ** Order compression fitting kit (see below)
Fluid Temperatures - 2-120C
Connections - BSP male, female and compression fittings
ACCESSORIES
Ordering Codes Description Price
0378145015 DN15 Compression Fitting Kit 16
0378145020 DN20 Compression Fitting Kit 20
Terminal Unit Valves
V48 Series
Three-way, Pressure Actuated
These water valves are especially designed for condensing units
cooled either by atmospheric or forced draft cooling towers.
They may be used on single, or multiple condenser hook-ups
to the tower. The valve senses the compressor head pressure
and allows cooling water to flow to the condenser, by-pass the
condenser, or to allow waterflow to both condenser and by-pass
line in order to maintain correct refrigerant head pressure.
A further advantage of this system is that the 3-way permits
a continuous water flow to the tower so the can operate
efficiently with a minimum of maintenance nozzles and wetting
surfaces. The valves can be used in non-corrosive refrigerant
systems. Ammonia power elements and valves designed
salt-water applications are available. The valves have a quick
opening characteristic.
FEATURES
Pressure balanced design
Free movement of all parts
Easy manual flushing
High Kv values
Pressure actuated
Can be used as mixing or diverting valve
Ordering
Codes
Thread
Size
Range
(bar)

Style
Capillary
Length (mm) Notes
List
Price
Straight Valves - Screwed (ISO 228)
V48AB-9510
1/2
4-20 50
750 -
193
V48AB-9600 4-16 13 256
V48AC-9510
3/4
4-20 50 207
V48AC-9600 4-16 13 293
Straight Valves - Screwed (ISO 7-RC)
V48AD-9510
1
6-20 50
750
-
559
V48AD-9600
4-16 13
593
V48AD-9602 A 593
V48AE-9510
1 1/4
6-20 50
-
574
V48AE-9600 4-16 13 621
Maritime Type (ISO 228)
V48BC-9600 3/4 4-16 13 750 B 561
Commercial Type (ISO 228)
V48AF-9300 1 1/2 6-14 5 - C 840
See page 42 for Style references
Notes:
A = Bodies in-line (port 3 below port 2)
B = Seawater resistant
C = Commercial type
16
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
Ordering
Codes Connection
Body
Size
Kvs
(Control)
Kvs
(By-pass)
Close-off
(kPa)
List
Price
3-way Mixing Configuration - Male Thread
VG5810AC
BSP
DN15
0.25 0.25
200
29
VG5810BC 0.4 0.4 26
VG5810CC 0.63 0.63 24
VG5810DC 1 1 26
VG5810EC 1.6 1.6
100
29
VG5810JC
DN20
2.5 2.5 30
VG5810KC 3.5 3.5 34
VG5890AC
Compression DN15
0.25 0.25
200
41
VG5890BC 0.4 0.4 41
VG5890CC 0.63 0.63 34
VG5890DC 1 1 34
VG5890EC 1.6 1.6 100 41
3-way + Built-in (Normally Open) Bypass Configuration - Male Thread
VG5510AC
BSP
DN15
0.25 0.25
200
37
VG5510PC 0.4 0.25 35
VG5510BC 0.4 0.4 37
VG5510QC 0.63 0.4 39
VG5510CC 0.63 0.63 34
VG5510RC 1.0 0.63 39
VG5510DC 1.0 1.0 34
VG5510SC
DN15
1.6 1.0
100
44
VG5510EC 1.6 1.6 38
VG5510TC
DN20
2.5 1.6 49
VG5510JC 2.5 2.5 46
VG5510UC 3.0 2.5 49
VG5510KC 3.0 3.0 49
VG5590AC
Compression DN15
0.25 0.25
200
63
VG5590PC 0.4 0.25 37
VG5590BC 0.4 0.4 26
VG5590QC 0.63 0.4 39
VG5590CC 0.63 0.63 39
VG5590RC 1.0 0.63 34
VG5590DC 1.0 1.0 39
VG5590SC 1.6 1.0
100
38
VG5590EC 1.6 1.6 27
2-way PDTO (Normally Open) Configuration - Female Thread
VG5200CC
BSP
DN15
0.63
-
200
24
VG5200DC 1 21
VG5200EC 1.6 21
VG5200JC
DN20
2.5 140 25
VG5200KC 3.5 100 25
VG5200MC DN25 5.5 62 38
2-way PDTC (Normally Closed) Configuration - Female Thread
VG5400AC
BSP
DN15
0.25
-
200
23
VG5400BC 0.4 23
VG5400CC 0.63 19
VG5400DC 1 19
VG5400EC 1.6 21
VG5400JC
DN20
2.5
100
25
VG5400KC 3.5 26
VG5400MC DN25 5.5 62 41
3-way Mixing - Female Thread
VG5800CC
BSP
DN15
0.63 0.63
200
23
VG5800DC 1 1 24
VG5800EC 1.6 1.6 24
VG5800JC
DN20
2.5 2.5
100
29
VG5800KC 3.5 3.5 29
VG5800MC DN25 5.5 5.5 62 46
Fluid Temperatures - 2-95C
Connections - BSP male, female and compression fittings
VG5000 Series
DN15-25, PN16
These valves are primarily designed to regulate the flow
of water and steam in response to the demand of a
controller in zone and terminal unit applications.
Following actuators are available:
VA-7010 ON/OFF Actuators
VA-7040 Thermal ON/OFF Actuators
VA-7060 Thermal Proportional Actuators
VA-745x Floating and Proportional Actuators
FEATURES
Forged brass body
2-way PDTO (normally open), 2-way PDTC (normally closed), 3-way mixing and
3-way mixing with built-in (normally open) bypass configurations
Built-in return spring
Inherent flow characteristic: quick opening
Ordering
Codes Connection
Body
Size
Kvs
(Control)
Kvs
(By-pass)
Close-off
(kPa)
List
Price
2-way PDTO (Normally Open) Configuration - Male Thread
VG5210AC
BSP
DN15
0.25
-
200
20
VG5210BC 0.4 28
VG5210CC 0.63 35
VG5210DC 1 21
VG5210EC 1.6 100 21
VG5210JC
DN20
2.5
-
140 27
VG5210KC 3.5 100 32
VG5290AC
Compression DN15
0.25
-
200
39
VG5290BC 0.4 39
VG5290CC 0.63 23
VG5290DC 1 25
VG5290EC 1.6 100 22
2-way PDTC (Normally Closed) Configuration - Male Thread
VG5410AC
BSP
DN15
0.25
-
200
21
VG5410BC 0.4 23
VG5410CC 0.63 21
VG5410DC 1 21
VG5410EC 1.6
100
22
VG5410JC
DN20
2.5
-
31
VG5410KC 3.5 27
VG5490AC
Compression DN15
0.25
-
200
21
VG5490BC 0.4 21
VG5490CC 0.63 22
VG5490DC 1 22
VG5490EC 1.6 100 22
Fluid Temperatures - 2-95C
Connections - BSP male, female and compression fittings
(Continued next column)
VALVES (cont)
17
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
VG6000 Series
DN15-25, PN16
These valves are primarily designed to regulate
the flow of water in response to the demand
of a controller in zone and terminal unit
applications.
Following actuators are available:
VA-7030 ON/OFF Actuators
VA-747x Electric Actuators
FEATURES
Forged brass body
2-way PDTC (normally open), 3-way mixing and diverting, 3-way mixing and
diverting with built-in bypass configurations
Inherent flow characteristic: quick opening
Ordering
Codes*
Body
Size
Connec.
Size
Kvs
(Control)
Kvs
(By-pass)
Close-off
(kPa)
List
Price
2-way PDTC Configuration
VG6210EC DN15 1/2 1.7
-
250 21
VG6210JC DN20 3/4 2.6 150 27
VG6210LC DN25 1 4.5 70 46
3-way Mixing and Diverting Configuration
VG6810EC DN15 1/2
1.7 (M),
1.7 (D)
1.2 (M),
1.3 (D)
250 25
VG6810JC DN20 3/4
2.5 (M),
2.6 (D)
1.6 (M),
1.8 (D)
150 30
VG6810LC DN25 1
4.5 (M),
4.5 (D)
3.1 (M),
4.5 (D
70 50
3-way Mixing and Diverting with built-in bypass
VG6510EC DN15 1/2
1.7 (M),
1.7 (D)
1.2 (M),
1.3 (D)
250 32
VG6510JC DN20 3/4
2.5 (M),
2.6 (D)
1.6 (M),
1.8 (D)
150 38
VG6510LC DN25 1
4.5 (M),
4.5 (D)
3.1 (M),
4.5 (D)
70 75
Note: M = Mixing, D = Diverting
Threaded Control Valves
VG1201, VG1801 Series
2 and 3-way Control Valves with Brass Ball
These ball valves are primarily designed to regulate the
flow of hot or chilled water and low-pressure steam
in response to the demand of a controller in heating,
ventilating and air-conditioning systems.
Following actuators are available:
ON/OFF, Floating or Proportional actuators - VA9104 Direct
Mounted Non-spring Return Actuators, M9108 Non-spring Return Actuators,
M9206 and M9216 Spring Return Actuators
FEATURES
Forged brass body
Inherent equal percentage flow characteristic in the in-line port of all valves
Ordering
Codes Body Size
Kvs
(Control Port)
List
Price
2-way Valves - Female Thread
VG1201AD
DN15
1.0 32
VG1201AE 1.6 32
VG1201AF 2.5 32
VG1201AG 4.0 32
VG1201AL 6.3 52
VG1201AN 10 30
VG1201BL
DN20
6.3 37
VG1201BN 10 34
VG1201CN
DN25
10 46
VG1201CP 16 42
VG1201DP
DN32
16 83
VG1201DR 25 77
VG1201ER
DN40
25 121
VG1201ES 40 114
VG1201FS
DN50
40 166
VG1201FT 63 160
3-way Valves - Female Thread
VG1801AD
DN15
1.0 44
VG1801AE 1.6 44
VG1801AF 2.5 44
VG1801AG 4.0 44
VG1801AL 6.3 66
VG1801AN 10 63
VG1801BL
DN20
6.3 47
VG1801BN 10 68
VG1801CN
DN25
10 96
VG1801CP 16 92
VG1801DP
DN32
16 116
VG1801DR 25 151
VG1801ER
DN40
25 176
VG1801ES 40 171
VG1801FS
DN50
40 253
VG1801FT 63 243
(Other sizes on request)
Fluid Temperatures - -30-+95C (-5-+95C with VA9104) chrome-plated brass ball/stem
types, -30-140C (-30-+100C with VA9104) stainless steel ball and stem fluid types
Connections - BSP female threaded body
See pages 43-44 for Actuator Selection Tables.
ACCESSORIES
Ordering Codes Description Price
M9000-510-5 Linkage kit for mounting to M9216 series actuators 35
M9000-520-5 Linkage kit for mounting to M9206 series actuators 21
M9000-525-5 Linkage kit for mounting to M9108 series actuators 27
18
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
VG7000 Series
DN15-50, PN16 Globe Valves
The VG7000 Series valves are primarily designed to regulate
the flow of water and steam in response to the demand of
a controller in heating, ventilating and air-conditioning systems.
FEATURES
Cast bronze body
2-way PDTO (normally open), 2-way PDTC (normally open),
3-way mixing configurations
BRASS TRIM VALVES
Ordering
Codes
Body
Size
Kvs
(Control)
Slotted
Stem* Valve Stroke
List
Price
2-way PDTC (Normally Open) - Female Thread
VG7201AS
DN15
0.25

8mm
77
VG7201AT - 77
VG7201BS
0.4

77
VG7201BT - 56
VG7201CS
0.63

81
VG7201CT - 81
VG7201DS
1.0

81
VG7201DT - 81
VG7201ES
1.6

81
VG7201ET - 58
VG7201FS
2.5

77
VG7201FT - 81
VG7201GS
4.0

77
VG7201GT - 58
VG7201LT DN20 6.3
-
81
VG7201NT DN25 10
13mm
100
VG7201PT DN32 16 129
VG7201RT DN40 25
19mm
152
VG7201ST DN50 40 194
2-way PDTO (Normally Closed) - Female Thread
VG7401AT
DN15
0.25
-
8mm
55
VG7401BS

144
VG7401BT
0.4
- 148
VG7401CS

58
VG7401CT
0.63
- 60
VG7401DS

58
VG7401DT
1.0
- 122
VG7401ES

58
VG7401ET
1.6
- 58
VG7401FS

58
VG7401FT
2.5
- 81
VG7401GS

60
VG7401GT
4.0
- 81
VG7401LS

81
VG7401LT
DN20
6.3
-
97
VG7401NT 10
13mm
108
VG7401PT DN32 16 139
VG7401RT DN40 25
19mm
182
VG7401ST DN50 40 231
Fluid Temperature - 2-140C (brass trim models), 2-170C (stainless steel trim models)
Connections - BSP female threaded body
(Continued next column)
STAINLESS STEEL TRIM VALVES
Ordering
Codes*
Body
Size
Kvs
(Control)
Slotted
Stem Valve Stroke
List
Price
2-way PDTC (Normally Open) - Female Thread
VG7203AT
DN15
0.25
-
8mm
139
VG7203BT 0.4 147
VG7203CT 0.63 176
VG7203DT 1.0 176
VG7203ET 1.6 191
VG7203FT 2.5 176
VG7203GT 4.0 176
VG7203LT DN20 6.3
-
213
VG7203NT DN25 10
13mm
271
VG7203PT DN32 16 315
VG7203RT DN40 25
19mm
455
VG7203ST DN50 40 560
2-way PDTO (Normally Closed) - Female Thread
VG7403AT
DN15
0.25
-
8mm
176
VG7403BT 0.4 176
VG7403CT 0.63 176
VG7403DT 1.0 176
VG7403ET 1.6 176
VG7403FT 2.5 176
VG7403GT 4.0 188
VG7403LT DN20 6.3
-
215
VG7403NT DN25 10
13mm
278
VG7403PT DN32 16 322
VG7403RT DN40 25
19mm
363
VG7403ST DN50 40 441
Notes: * When using VA-7310 Series actuators a valve with a slotted stem
(VG7xxxxS) is required.
Fluid Temperature - 120C max. (in conjunction with VA-7310).
The valves and actuators can be ordered separately or factory mounted.
When factory mounted, please add +M to the order code for the actuator.
Please contact our Sales Support Team for mounting price.
Please refer to page 43-44 for Actuator Selection Tables.
3-WAY MIXING CONFIGURATION - BRASS TRIM VALVES
Ordering
Codes*
Body
Size
Kvs
(Control)
Slotted
Stem* Valve Stroke
List
Price
2-way PDTC (Normally Open) - Female Thread
VG7802AS
DN15
0.25

8mm
89
VG7802AT - 152
VG7802BS
0.4

89
VG7802BT - 94
VG7802CS
0.63

89
VG7802CT - 94
VG7802DS
1.0

89
VG7802DT - 94
VG7802ES
1.6

89
VG7802ET - 74
VG7802FS
2.5

89
VG7802FT - 94
VG7802GS
4.0

89
VG7802GT - 74
VG7802LS
DN20 6.3

107
VG7802LT
-
87
VG7802NT DN25 10
13mm
110
VG7802PT DN32 16 135
VG7802RT DN40 25
19mm
318
VG7802ST DN50 40 210
(Continued next column)
VALVES (cont)
19
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
3-WAY MIXING CONFIGURATION - STAINLESS STEEL TRIM VALVES
Ordering
Codes Body Size
Kvs
(Control)
Slotted
Stem Valve Stroke
List
Price
3-way Mixing Configuration - Female Thread
VG7804AT
DN15
0.25
-
8mm
236
VG7804BT 0.4 236
VG7804CT 0.63 236
VG7804DT 1.0 161
VG7804ET 1.6 204
VG7804FT 2.5 236
VG7804GT 4.0 204
VG7804LT DN20 6.3
-
208
VG7804NT DN25 10
13mm
317
VG7804PT DN25 16 426
VG7804RT DN32 25
19mm
435
VG7804ST DN40 40 472
Fluid Temperature - 120C max. (in conjunction with VA-7310)
The valves and actuators can be ordered separately or factory mounted.
When factory mounted, please add +M to the order code for the actuator.
Please refer to pages 43-44 for Actuator Selection Tables.
VG8000N Series
DN15-150, PN16 Flanged Valves
These valves are primarily designed to regulate the flow of
water and steam applications.
A variety of electric and pneumatic actuators are available.
FEATURES
Nodular cast iron body
Large range of valves
Fluid temperature 0-180C (with Glycerine cup -10-+180C)
Ordering
Codes* Body Size
Kvs
(Control)
List
Price
2-way PDTC (Normally Open)
VG82A9S1N
DN15
1.0 387
VG82A8S1N 0.16 387
VG82A7S1N 0.25 387
VG82A6S1N 0.4 387
VG82A5S1N 0.63 288
VG82A4S1N 1.0 238
VG82A3S1N 1.6 253
VG82A2S1N 2.5 238
VG82A1S1N 4.0 253
VG82B2S1N
DN20
4.0 310
VG82B1S1N 6.3 296
VG82C2S1N
DN25
6.3 259
VG82C1S1N 10 259
VG82D2S1N
DN32
10 431
VG82D1S1N 16 336
VG82E2S1N
DN40
16 276
VG82E1S1N 25 276
VG82F1S1N DN50 40 362
VG82G1S1N DN65 63 431
VG82H1S1N DN80 100 542
VG82J1S1N DN100 160 640
VG82K1S1N DN125 250 974
VG82L1S1N DN150 350 1,299
(Continued next column)
Flanged Control Valves
Ordering
Codes* Body Size
Kvs
(Control)
List
Price
3-way Mixing Configuration
VG88A6S1N
DN15
0.4 540
VG88A5S1N 0.63 333
VG88A4S1N 1.0 333
VG88A3S1N 1.6 333
VG88A2S1N 2.5 333
VG88A1S1N 4.0 333
VG88B2S1N
DN20
4.0 431
VG88B1S1N 6.3 431
VG88C2S1N
DN25
6.3 360
VG88C1S1N 10 360
VG88D2S1N
DN32
10 606
VG88D1S1N 16 502
VG88E2S1N
DN40
16 407
VG88E1S1N 25 431
VG88F1S1N DN50 40 510
VG88G1S1N DN65 63 576
VG88H1S1N DN80 100 736
VG88J1S1N DN100 160 990
VG88K1S1N DN125 250 1,412
VG88L1S1N DN150 350 1,786
3-way Diverting Configuration
VG89A6S1N
DN15
0.4 612
VG89A5S1N 0.63 494
VG89A4S1N 1.0 612
VG89A3S1N 1.6 494
VG89A2S1N 2.5 612
VG89A1S1N 4.0 377
VG89B2S1N
DN20
4.0 614
VG89B1S1N 6.3 496
VG89C2S1N
DN25
6.3 383
VG89C1S1N 10 406
VG89D2S1N
DN32
10 674
VG89D1S1N 16 544
VG89E2S1N
DN40
16 451
VG89E1S1N 25 478
VG89F1S1N DN50 40 505
VG89G1S1N DN65 63 624
VG89H1S1N DN80 100 795
VG89J1S1N DN100 160 1,084
VG89K1S1N DN125 250 1,728
VG89L1S1N DN150 350 2,057
ACCESSORY
Ordering Code Description Price
VA1000-EP Extension mounting kit for fluid temperature >140C 98
Notes: * For factory mounted valve actuators, add suffix +M to the actuator
ordering code: i.e. VG8xxxS1N+M.
To order a valve with Glycerine cup packing, add suffix 20 to end of ordering
code: i.e. VG8xxxS1N20.
Teflon free models are available on request.
20
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
VG8000V Series
DN15-150, PN25 Flanged Valves
These valves are primarily designed to regulate the
flow of water and low pressure steam in response to
the demand of a controller, in heating, ventilating and
air-conditioning systems.
A variety of electric and pneumatic actuators are available.
FEATURES
Nodular cast iron body
2-way PDTC (normally open) and 3-way mixing configurations
Fluid temperature 0-140C
Ordering
Codes* Body Size
Kvs
(Control)
List
Price
2-way PDTC (Normally Open)
VG82A2V1N
DN15
2.5 342
VG82A1V1N 4.0 342
VG82B1V1N DN20 6.3 351
VG82C1V1N DN25 10 360
VG82D1V1N DN32 16 347
VG82E1V1N DN40 25 303
VG82F1V1N DN50 40 483
VG82G1V1N DN65 63 435
VG82H1V1N DN80 100 451
VG82J1V1N DN100 160 794
VG82K1V1N DN125 250 1,053
VG82L1V1N DN150 350 1,467
3-way Mixing Configuration
VG88A2V1N
DN15
2.5 431
VG88A1V1N 4.0 431
VG88B1V1N DN20 6.3 504
VG88C1V1N DN25 10 329
VG88D1V1N DN32 16 486
VG88E1V1N DN40 25 418
VG88F1V1N DN50 40 511
VG88G1V1N DN65 63 582
VG88H1V1N DN80 100 841
VG88J1V1N DN100 160 996
VG88K1V1N DN125 250 1,263
VG88L1V1N DN150 350 2,169
Note: * For factory mounted valve actuators, add suffix +M to the actuator
ordering code: i.e. VG8xxxJ1V1N+M.
ACCESSORY
Ordering Code Description Price
VA1000-EP Extension mounting kit for fluid temperature >140C 98
Gas Valves
Screwed
Types
Flanged
Types
GH-5000 Series
Electro-Hydraulic Actuator Gas Valves
These sturdy and reliable, single seat valves
are fast closing and slow opening. Valves are
normally closed (NC). EC type-tested and
certified as safety shut-off valve
Class A (EN 161).
APPLICATIONS
Typical applications include commercial and
industrial boilers, burners, ovens, rooftop units,
make up air heaters, hot water heaters, kilns,
and paint booths.
Ordering
Codes Size
Max. Operating
Pressure (mbar)
Opening
Time Stroke
List
Price
Flanged Connections with Closed Position Indicator
GH-5229-2610 2
1,000
8 sec. 22mm
544
GH-5629-3611 2 1/2 992
GH-5629-4611 3
800
1,018
GH-5729-5610 4
13 sec. 36mm
1,298
GH-5729-6610 5 650 1,715
GH-5729-7610 6 350 1,877
Screwed Connections with Closed Position Indicator
GH-5119-5610 1 1/2 800
13 sec. 36mm
990
GH-5219-6610 2 650 579
GH-5619-7611 2 1/2 350 760
Power Supply - 230Vac, 50/60Hz
Compression Fitting - EN 50262
Media - Gas families to DVGW - G 260/I 1, 2 and 3. Gas family.
Protection Class - IP54 (NEMA 1)
CO Sensors
CD-W00-00-1 Series
Wall Mount Transmitter
These sensors measure and transmit CO levels, ranging from
0-2,000 parts per million (ppm).
Specific applications include: Demand Control Ventilation (DCV),
Fresh Air and Indoor Air Quality (IAQ), and Rooftop Air Handling
Economiser Controls System.
These sensors are designed to work in stand-alone mode or as part
on any integrated Building Automation System (BAS). They are
easy to install and require no maintenance or field calibration.
FEATURES
Response time (0-63%): 1 minute
Accuracy at 25C: 50 ppm + 3.0% of reading
Ordering
Codes Description
List
Price
CD-W00-00-1 CO Transmitter - Wall Mount 339
Accessories
ACC-DWCLIP-0 Drywall Spring-Clip Mounting Kit 27
Y65T31-0
Multiple Primary Transformer, 40VA, 120/208/240V
Primary, 24V Class 2 Secondary
49
Power Supply - 20-30Vac (18-30Vdc, Class 2)
Operating Temperature - -5-+45C
Size - 120 x 80 x 32mm
Humidity Range - 0-85%
VALVES (cont) / SENSORS / THERMOSTATS
21
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
CD-Wxx-00-0 Series
Wall Mount Transmitters
This range of CD-Wxx-00-0 sensors measure and transmit
CO
2
levels, ranging from 0-2,000 parts per million (ppm).
Specific applications include: Demand Control Ventilation
(DCV), Fresh Air and Indoor Air Quality (IAQ), and Rooftop
Air Handling Economiser Controls System.
These sensors are designed to work in stand-alone mode
or as part on any integrated Building Automation System
(BAS). They are easy to install and require no maintenance
or field calibration.
FEATURES
Response time (0-63%): 1 minute
Accuracy at 25C: 50 ppm + 3.0% of reading
Ordering
Codes Description
List
Price
CD-WA0-00-0 CO Transmitter with Analogue Temperature Output 525
CD-WR0-00-0 CO Transmitter with Relay 675
CD-WRD-00-0 CO Transmitter with Relay and Display 697
Replacement Part
ACC-DWCLIP-0 Drywall Spring-clip Mounting Kit 27
Accessories
ACC-CD-S
Relay Setpoint Software Kit; includes software
and interface cable to reset the On and Off relay
setpoints for CD-WR0-00-0 or CD-WRD-00-0
422
Y65T31-0
Multiple Primary Transformer, 40VA, 120/208/230V
Primary, 24V Class 2 Secondary
49
Power Supply - 20-30Vac (18-30Vdc), Class 2
Signal Output - 0-10V (default), 0-20mA or 4-20mA signal
Operating Temperature - -5-+45C
Humidity Range - 0 to 85%
Size - 109 x 80 x 37mm
CD-Pxx-00-0 Series
Duct Mount Transmitters
These sensors measure and transmit CO
2
levels, ranging
from 0-2,000 parts per million (ppm).
Specific applications include: Demand Control Ventilation
(DCV), Fresh Air and Indoor Air Quality (IAQ), and Rooftop
Air Handling Economiser Controls System.
The sensors produce a 0-10V (default), 0-20 mA or 4-20 mA signal.
FEATURES
Response time (0-63%): 1 minute
Accuracy at 25C: 30 ppm + 2.0% of reading
Ordering
Codes Description
List
Price
CD-P00-00-0 CO Transmitter - Duct Mount 539
CD-PR0-00-0 CO Transmitter with Relay - Duct Mount 650
Replacement Part
ACC-CD-CFK1 Conduit Adaptor Kit 42
Accessories
ACC-CD-S
Relay Setpoint Software Kit; includes software and
interface cable to reset the On and Off relay setpoints
for CD-PR0-00-0
422
Y65T31-0 Multiple Primary Transformer, 40VA, 120/208/230V
Primary, 24V Class 2 Secondary
49
Power Supply - 20-30Vac (18-30Vdc), Class 2
Signal Output - 0-10V (default), 0-20mA or 4-20mA signal
Operating Temperature - -5-+45C
Humidity Range - 0 to 85%
Size - 80 x 80 x 64mm (head), 80-140mm (stem length), 15mm (stem )
HX-9100 Series
Dew Point Sensors
The HX-9100 is used to prevent condensation on surfaces such
as cold water pipes, cool ceilings and windows. The sensor
provides override functions when condensation is forming.
FEATURES
Hysteresis: 1%
Output: open collector closed: 0.5Vdc max
or + 0.5Vdc
Ordering
Codes Action Output at Condensation
List
Price
HX-9100-8001 ON/OFF Open collector closed, 0.5Vdc max. 32
HX-9100-9001 0-10Vdc +0.5Vdc 97
Power Supply - 15Vdc 10%
Size - 50 x 15 x 10mm
Protection Class - IP44
Dew Point Sensors
Flow and Float Controls
F61 Series
Flow Switches for Liquid
These switches can be used in liquid lines carrying water,
sea water, swimming pool water, ethylene glycol or other
liquids not harmful to the specified materials.
The SPDT contacts can be wired to energise one device
and de-energise another when liquid flow either exceeds
or drops below the set flow rate. Pipe insert models and the
T-body types for low-flow applications are available.
Typical applications: to shut down the compressor on liquid chiller
systems, to prove flow on electric immersion heaters and to give a
signal or alarm when the pump on condenser cooling system shuts down.
FEATURES
T-body and pipe-insert types
Vapour tight IP67 enclosures
Stainless steel pipe-insert type
Large wiring space
Range screw easy accessible
Ordering
Codes
Range
(bar) Connection Notes
List
Price
IP43 Types
F61SB-9100 0.15-46 dm/s R1 DIN2999 (ISO R7) A 113
F61SD-9150
0.04-0.07 dm/s
1/2 -14 NPTF
T-body -
110
F61SD-9175 3/4 -14 NPTF 112
IP67 Types
F61TB-9100
0.15-46 dm/s R1 DIN2999 (ISO R7)
B 135
F61TB-9200 C 285
F61TD-9150 0.04-0.07 dm/s 1/2 -14 NPTF T-body - 132
Notes:
A = Includes three paddles 1, 2, 3 stainless steel AISI 301
B = Includes four paddles, 1, 2, 3 and 6 stainless steel AISI 301
C = Stainless steel body, bellows, rod with three st.st. AISI 304 paddles 1, 2, 3
Switch Action - SPDT, 15(8)a, 230Vac (220Vac on IP67 types)
Size - 100 x 60 x 90mm
Protection Class - As table
ACCESSORIES
Ordering Codes Description Price
PLT69-11R 6 Stainless steel AISI 301 paddle 1
KIT21A602 Four paddles 1, 2, 3 and 6 St.St. AISI 301 10
SENSORS / THERMOSTATS
22
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
F62 Series
Air Flow Switch
The F62 switch detects air flow, or the absence of air flow,
by responding only to the velocity of air movement within
a duct. The control can be wired to open one circuit
and close a second circuit (SPDT) for either signaling
or interlock purposes. Failure of air flow during normal
operation of air handling systems may cause over-heating,
coil icing and other conditions that may be detrimental
to the equipment.
Typical applications include: Make-up air systems, air-cooling or heating processes
and exhaust systems.
FEATURES
Polycarbonate carbonate IP43 enclosure
Large wiring space
Range screw easily accessible.
Ordering
Codes Max. Air Velocity Note
List
Price
F62SA9100 10 m/sec A 81
Note: A = With 55mm paddle (mounted) and separate 80mm paddle
Switch Action - SPDT, 15(8)A, 230Vac
Enclosure - Plastic polycarbonate
Size - 100 x 60 x 62mm (blade 196mm)
Protection Class - IP43
ACCESSORIES
Ordering Codes Description Price
PLT112-1R Air Flow Plate - 55 x 175mm 6
PLT112-2R Air Flow Plate - 80 x 175mm 5
HT-9000 Series
Wall Mount, Humidity Sensors
These sensors measure humidity over the entire range of
0-100% RH (non condensing) and have a wide operating
temperature range. Its fast response, reliable long-
term performance makes this transmitter well suited for
refrigeration and HVAC installations. This range also includes
models with an integrated temperature sensing element.
FEATURES
Humidity Accuracy 4% RH from 10 to 90% RH
Temperature Outputs 0-10Vdc, NTC K2, Pt 100, Pt 1000, A99
Ordering
Codes Temp. Range Temp. Output Humidity Output
List
Price
HT-9005-URW
0-60C
Pt100
0-10Vdc
194
HT-9009-URW A99 130
Humidity Range - 0-100% (non condensing)
Supply Voltage - 12-30Vdc or 24Vac +15%
Size - 81 x 81 x 31mm
Protection Class - IP30
Old HT-9000 Sensors Replacement Sensors
HT-9000-URW HT-1300-UR
HT-9001-URW HT-1301-UR
HT-9003-URW HT-1303-UR
HT-9006-URW HT-1306-UR
F63 Series
Liquid Level Float Switches
These switches can be used in open
or closed tanks where a desired
liquid level has to be maintained and
installations handling water, swimming
pool water, sea water, brine, ethylene glycol or
other liquids not harmful to the specified materials.
The SPDT contacts can be wired to close one circuit and open a second circuit when
the liquid level rises above or falls below the required level. The switch maintains the
liquid level within (approx.) 13mm.
There are three different types available. These float switches should not be used for
liquids lighter than water (density less than 0.95 kg/dm
3
).
FEATURES
Solid polycarbonate float
Vapour tight IP67 enclosure
Convenient wiring terminals
Ordering
Codes Connection Notes
List
Price
F63BT-9101
1-11 1/2 NPT
A 160
F63BT-9102 B 176
F63BT-9200 R1 DIN2999 (ISO R7) C 345
Notes:
A = Plastic float, brass body, phosphor bronze bellows (used with non corrosive liquid)
B = Plastic float, stainless steel bellows (for water with high calcium content)
C = Plastic float, stainless steel body, rod, bellows (AISI 316L version)
Switch Action - SPDT, 15(8)A, 230Vac
Size - 100 x 60 x 61mm (head), 215-225mm (float length)
Protection Class - IP67
ACCESSORY
Ordering Codes Description Price
FLT001N001R Plastic Float 43
SENSORS / THERMOSTATS (cont)
HT-1000 Series
Room Humidity Sensors
This new sensor provides an active sensing of relative
humidity and, on specific models, also active/passive sensing
of temperature in HVAC applications.
It features a polymer capacitance humidity sensing element
and provides a voltage output signal within either 2% or 4%
accuracy proportional to 0-100 % relative humidity. Its fast
response, reliable long-term performance makes this transmitter
well suited for HVAC installations.
They are designed to work in stand-alone mode or as part on
any integrated Building Automation System (BAS).
FEATURES
Humidity accuracy 2% RH from 0-100% RH (HT-1201-UR)
Temperature outputs 0-10Vdc, NTC K2, Pt1000
Transmitter is resistant to many hostile environments
Polymer humidity sensing element integral on chip
Ordering Codes Accuracy Temp. Output Temp. Range*
List
Price
HT-1201-UR 2% 0-10Vdc 0-40C 307
HT-1300-UR
4%
- - 175
HT-1301-UR 0-10Vdc 0-40C 214
HT-1303-UR NTC K2
-
186
HT-1306-UR Pt1000 197
* If sensing temperature output is present
Supply Voltage - 12-30Vdc or 24Vac, 15% @ 50/60Hz
Size - 80 x 80 x 32mm
Protection Class - IP30
ACCESSORIES
Ordering Codes Description Price
TM-1100-8931 Surface Mounting Base 14
TM-9100-8900 Special Tool to open module 11
Humidity Sensors
23
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
PT-5217 Series
Pressure Transmitters
These transmitters accurately measure pressure
and converts the measurement into a 0-10V
signal. They are especially adapted to measure
air, water and inert gases pressure.
It can also be used in pneumatic control systems to convert
pneumatic into electric standard signals.
FEATURES
Low zero drift/time
Low sensibility to ambient temperature change
Low hysteresis
High accuracy
Splash proof enclosure
Ordering
Codes
Operating
Range
Max. Overload
Pressure
Output
Signal
List
Price
PT-5217-7011 0-100 kPa 200 kPa
0-10V
367
PT-5217-7101 0-1000 kPa 2000 kPa 367
Supply Voltage - 24Vac 15%/10%, 50/60Hz or 13.5-33Vdc, max. 5 mA
Mounting - Direct mounting, 1.5m cable included
Size - 86 x 40mm
Protection Class - IP65
ACCESSORIES
Ordering Codes Description Price
EQ-6056-7000 Mounting Kit for plastic hose 4 x 6mm 70
EQ-0100-7001 Mounting Kit for DIN-rail 32
HT-9000 Series
Duct Mount, Humidity Sensors
The HT-9000 Series measures humidity over the
entire range of 0-100% RH (non condensing) and
has a wide operating range. Its fast response,
reliable long-term performance makes this
transmitter well suited for refrigeration and HVAC
installations. This range also includes models with
an integrated temperature sensing elements.
FEATURES
Humidity accuracy 4% RH from 10-90% RH
Temperature outputs 0-10Vdc, NTC K2, Pt 100, Pt 1000, A99
Ordering
Codes
Temp.
Range
Temp.
Output
Probe
Length
Humidity
Output
List
Price
HT-9000-UD1 - -
153mm 0-10Vdc
133
HT-9001-UD1
0-40C
0-10Vdc 252
HT-9003-UD1 NTC K2 194
HT-9005-UD1
0-60C
Pt100 266
HT-9006-UD1 Pt1000 219
HT-9009-UD1 A99 217
HT-9000-UD2 - -
230mm 0-10Vdc
209
HT-9001-UD2
0-40C
0-10Vdc 294
HT-9003-UD2 NTC K2 247
HT-9005-UD2
0-60C
Pt100 226
HT-9006-UD2 Pt1000 267
HT-9009-UD2 A99 267
Supply Voltage - 12-30Vdc or 24Vac +15%
Size - 74.5 x 74.5 x 52mm (head), 25mm (probe )
Protection Class - IP30
P232 Series
Sensitive Differential Switch
This switch senses a change in the differential pressure
(either velocity pressure or pressure drop across a
restriction) as the air flow changes. The pressure, as
sensed by two sensing ports, is applied to the two sides of a
diaphragm in the control. The spring loaded diaphragm moves
and actuates the switch.
The series P232 can also be used to detect small positive gauge pressure by using
only the high pressure connection and leaving the low pressure connector open, or
to detect a vacuum by using only the low pressure connection and leaving the high
pressure connector open to ambient pressure.
FEATURES
E asy to read setpoint scale
Wide range (1-125mm water column)
Small differential (1mm water column) at bottom of range
Large wiring space
Versatile mounting options
APPLICATIONS
This (differential) pressure switch is used to sense flow of air, single or differential
air pressure. Typical applications include: Clogged filter detection, detection of
frost on air-conditioning coils and initiation of defrost cycle, air proving in heating or
ventilation ducts, maximum air flow controller for variable air volume system.
Ordering
Codes
Switch point
Range (in. wc)
Switching
Differential (in. wc)
List
Price
P232A-B-AAC 0.2-1.6 bar < 0.1 33
Size - 72 x 72 x 52mm
Pressure Switches
Power Supply - 24Vac/dc 10%
Output Signal - 0-10Vdc (1k min) or 4-20mA (500 max)
Response Time - 0.8/4 secs (selectable by jumper)
Bursting Pressure - 50 kPa
Media - Suitable for air and non-aggressive gases
Protection Class - IP54
Accessories include fixing screws, two plastic tube connectors and 2m tube 4 / 7mm.
Customised models are available upon request to Sales Support Team.
Pressure Transmitters
DP2500, DP0100, DP0250 Series
Differential Pressure Transmitters
The DP Low Differential Pressure Transmitter series is
an accurate and cost competitive solution for measuring
low pressures of air and non-aggressive gases. Ideal for
monitoring and controlling pressures in building automation,
HVAC and clean room systems.
The DP series accurately measures low differential
pressure and converts the measurement into a standard
proportional 0-10V signal or 4-20mA. Pressure ranges are
selected using the internal jumper switches.
FEATURES
Eight measurement ranges in one device (DP2500)
Four digit display
AutoZero option (maintenance free)
Selectable response time
Easy mounting
Ordering
Codes Operating Ranges AutoZero Display
List
Price
DP2500-R8
100-+100 Pa, 0-100 Pa,
0-250 Pa, 0-500 Pa,
0-1000 Pa, 0-1500 Pa,
0-2000 Pa, 0-2500 Pa
- - 224
DP2500-R8-AZ

- 293
DP2500-R8-D -

270
DP2500-R8-AZ-D

338
DP0100-AZ
50-+50 Pa, 100-+100 Pa

- 293
DP0100-AZ-D

338
DP0250-AZ
0-100 Pa, 0-250 Pa

- 293
DP0250-AZ-D

338
(Continued next column)
24
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
P20 Series
Pressure Controls for Air-conditioning and
Heat Pump Applications
The P20 series high and low limit (cut-out) controls for
all non-corrosive refrigerants are compact pressure
controls ideally suited for commercial or residential
packaged air-conditioning units, heat pumps, small water
chillers, ice cube machines and other applications where
a semi fixed setting is acceptable or required and where
mounting space is limited.
The P20 series includes auto reset as well as manual reset models and is factory set.
A special setting tool is available while also field (screwdriver) adjustable models can
be chosen.
FEATURES
Field proven reliability
Reset tab must be released before restart (trip free manual reset)
Compact design
Enclosed dust-tight switch
SPDT contact with special terminals
Test pressure 53 bar
Designed for at least 300,000 cycles
(Continued next column)
Ordering
Codes
Range
(bar)
Diff.
Fixed
Set at
(bar)

Style
Capillary
Length
List
Price
Open Low, Auto Reset
P20EA-9610C
0.5-10
0.9
1.5
13
90cm 43
P20EA-9611A 0.5
120cm
44
P20EA-9611C 1.5 44
P20EA-9611D 2 44
P20EA-9611F
3
44
P20EA-9620F
1.5
90cm 43
P20EA-9621D 2 120cm 45
Open High, Auto Reset
P20EA-9160L
7-29
3.1 17 45A
90cm
44
P20EA-9560Y 3.5 29
50
46
P20EA-9561K 1.2 16 46
P20EA-9660L
3.1
17
13
43
P20EA-9660M 18 43
P20EA-9670L 4.6
17
43
P20EA-9681L 6.5 120cm 44
P20EA-9550V 1.4 26 50 90cm 46
P20EA-9551H 1.2 15 35 100cm 43
P20EA-9901Z 14-41 6.2 30
34 90cm
51
P20EA-9960L
7-29
3.1 17 43
P20EA-9961 2.8 8 10
HIGH PRESSURE CONTROL
Ordering
Codes
Range
(bar)
Diff.
Fixed
Set at
(bar)

Style
Capillary
Length
List
Price
Open High, Auto Reset
P20EA-9681T
7-29
7.1 24 13 120cm 44
P20EA-9950C 1.1 10
34 90cm
43
P20EA-9950K 1.2 16 43
P20EA-9960C 2.8 10 43
Open Low, Manual Reset *
P20FA-9610B
0.5-10 -
1
13 90cm
44
P20FA-9610F 3 44
Open High, Manual Reset *
P20GA-9550U
7-29 -
25 50
90cm
50
P20GA-9650X 28
13
44
P20GA-9651N 19
120cm
44
P20GA-9651U 25 46
P20GA-9950K 16
34 90cm
44
P20GA-9950T 24 44
P20GA-9950X 28 44
Note: * Wrench adjustment. Quantity orders only.
UNIVERSAL REPLACEMENTS (Low and High Pressure Control)
Ordering
Codes
Range
(bar)
Diff.
Fixed
Set at
(bar)

Style
Cap.
Length Action
List
Price
Auto Reset Types
P20EA-9530FC
0.5-10 2.1 3
50
90cm
Open Low
54
P20EA-9630FC
13
54
P20EA-9670X 7-29 5.2 28
Open High
43
P20EL-9670TC 14-42 6.5 37 62
Manual Reset Types
P20FA-9510FC 0.5-10
6.5
3
50
90cm
Open Low 55
P20GA-9550XC
7-29 28
Open High
55
P20GA-9650XC
13
55
P20GL-9650TC 14-42 37 64
See page 42 for Style references
Capillary - 90cm length
Size - 85 x 56 x 17.5mm (head)
Switch Action - SPDT, 8A
SENSORS / THERMOSTATS (cont)
P233 Series
Sensitive Differential Switches
This switch senses a change in the (differential) pressure
as the airflow changes. The (differential) pressure is applied
to the two sides of a diaphragm in the control.
The spring-loaded diaphragm moves and actuates the
switch. They can also be used to detect small positive gauge
pressure or to detect a vacuum.
FEATURES
One switch to measure relative differential pressure
Various accessories available
Compact and durable construction
Easy mounting and wiring, various
Standard PG 11 nipple and optional DIN 43650 connector
Accurate and stable switch
SPDT contact standard
APPLICATIONS
This (differential) pressure switch is used to sense flow of air, single or differential air
pressure. Typical uses include: Detect clogged filter, detect frost or ice build-up on air-
conditioning coils, air proving in heating or ventilation ducts, maximum airflow controller
for variable air volume system, detect blocked flue or vent, monitor fan operation.
Ordering
Codes
Switch Point
Range (mbar)
Switching
Differential (mbar)* Notes
List
Price
P233F-P3-AAC 0.3 fixed
< 0.3
- 40
P233A-4-AAC
0.5-4
- 41
P233A-4-AHC A 42
P233A-4-PAC
50-400 Pa
- 24
P233A-4-PHC A, B 39
P233A-4-PKC B, C 50
P233A-4-AKC 0.5-4 C 40
P233A-10-AAC
1.4-10
< 0.5
- 33
P233A-10-AHC A 37
P233A-10-PAC
140-1000 Pa
- 36
P233A-10-PKC B, C 38
P233-10-AKC 1.4-10 C 40
P233A-50-AAC 6-50 < 1 C 33
P233A-10-PHC 140-1000 Pa < 0.5 A, B 40
* Switching differential is maximum value mid-range Bulk packs on request.
Notes:
A = GMT008N600R + BKT024N001R
B = Scale in Pa
C = FTG015N602R (2x) + 2m tube 4/7mm
Contact Rating - SPDT, 5(2)A, 250Vac
Size - 72 x 72 x 52mm
25
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
P28 Series
Oil Protection Switches
These controls measure the pressure differential between
the pressure generated by the oil pump and the refrigerant
pressure at the crankcase.
A built-in time delay switch allows for pressure-pick up on
start and avoids nuisance shutdowns on pressure drops of
short duration during the running cycle.
The compressor can never run longer than the
pre-determined time on low oil pressure. Controls are
available only for manual reset after cut-out.
FEATURES
Heavy duty pressure elements
Safety lock-out with trip-free manual reset
Ambient compensated timing
Dust-tight PENN switch
APPLICATION
These oil protection controls are designed to give protection against low net lube oil
pressure on pressure lubricated refrigeration compressors.
Ordering
Codes
Range
(bar)

Style
Time
Delay (s) Refrigerant Notes
List
Price
Voltage 115/230
P28DA-9341
0.6-4.8
5 50
non-corr.
A 267
P28DA-9660 13 90 - 279
Voltage 230
P28DJ-9360
0.6-4.8
5
90
non-corr. B 435
P28DJ-9861 15 NH3 B, D 426
P28DP-9300
5
-
non-corr.
C 156
P28DP-9340 50
-
237
P28DP-9360 90 237
P28DP-9380
120
214
P28DP-9381 E, F 286
P28DP-9640
13
50
-
221
P28DP-9660 90 221
P28DP-9680 120 229
P28DP-9840
15
50
NH3
265
P28DP-9860 - 90 H 303
Voltage 115/230
P28DN-9750 - 15 50 NH3 E, G, H 308
See page 42 for Style references
Notes:
A = Includes plastic PG nipple 13.5 + two flare nuts
B = IP66 enclosure
C = Without time relay
D = Includes two connectors CNR003N001
E = Concealed adjustment
F = Set 0.65 bar
G = Set 1.5 bar
H = No switch action
Switch Action - Open low, alarm and safe light contacts
Contact Rating - 15(8)A, 230Vac
Size - 134 x 144 x 53mm
REPLACEMENT TIME RELAYS
Ordering
Codes Timing (s) Voltage Switch Action
List
Price
RLY13A603R 90 120/240
Manual reset,
dual voltage (AC)
130
RLY13A627R 120
24 Manual reset, 24Vac/dc
171
RLY13A635R 90 171
P45 Series
Oil Protection Switches
The series P45 controls are designed to give protection against low lube-oil pressure
on pressure lubricated refrigeration compressors.
There are several million in use today. The controls measure the pressure differential
(net oil pressure) between the pressure generated by the oil pump and the refrigerant
pressure at the crankcase. A built-in time delay switch allows pressure build-up
during start and avoids nuisance shut-down on pressure drops of short duration
during the running cycle.
FEATURES
Heavy duty pressure elements
Key specifications match/exceed other brands
Accurate 0.2 bar switch differential standard
Adjustable or fixed setpoint
Safelight output standard
Trip-free manual reset
High current rated output
Ambient compensated timing
Ordering
Codes
Range
(bar)
Setting
(bar)
Time
Delay (s)

Style
List
Price
Voltage 230Vac
P45NBB-9361B
0.5-4
0.6
90
5
227
P45NBB-9381B 120 212
P45NBB-9640C
0.7
50
13
193
P45NBB-9660C
90
193
P45NBB-9660Q 1.8 254
P45NBB-9680C 0.7 120 193
Voltage 115/230
P45NCA-9056
0.5-4
0.45 50
13
235
P45NCA-9104 0.7 120 230
See page 42 for Styles

Switch Action - Open low, alarm and safe light contacts
Switch Rating - 15(8)A, 230Vac
Size - 83 x 144 x 58mm
P74 Series
Differential Pressure Switches
These pressure switches incorporate two opposing pressure elements
and an adjustable range setpoint spring with a calibrated scale.
The control switches at the indicated setpoint on an increase in
differential pressure and switches back to the normal position when
the different pressure decreases to the setpoint less the mechanical
switching differential.
FEATURES
Heavy duty pressure elements
These controls may be used in combination with series P28 lube oil
protection control on two compressor, single motor units
APPLICATIONS
These controls are designed to sense pressure differences between
two points and may be used as operating or limit controls. Typical applications are
to detect flow across a chiller or water cooled condenser, to detect flow in a heating
system and sensing lube oil pressure differential on refrigeration compressors.
Ordering
Codes
Range
(bar)
Mech.
Diff. (bar)

Style Switch Action Notes


List
Price
P74DA-9300
0.6-4.8
0.7-2
adjustable
5
DPST, 10A, contacts
Open Low
-
176
P74DA-9600 13 182
P74EA-9300
0.3 fixed
5
SPDT, 5A, contact
Open High
168
P74EA-9600 13 208
P74EA-9700
15
A 263
P74EA-9701 A, B, C 288
P74FA-9700 0-1 0.1 fixed
SPDT, 3A, contact
Open High
D 262
P74FA-9701 2-8 0.7 fixed A 351
Notes: See page 42 for Style references
A = For NH3
B = Set 1 bar
C = Concealed adjustment
D = For water
Size - 172 x 101 x 53mm
26
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
P48 Series
Steam Pressure Switches
The P48 series has been developed for special applications
where pressure must be controlled. All models have an
adjustable differential depending on the range (see type
number selection table). The P48AAA-9110 and
P48AAA-9120 has the power element outside the case.
All the models have phosphor bronze bellows and brass
pressure connections except the P48AAA-9150. This model
has a stainless steel bellows and pressure connection and is
provided with a brass adapter 1/4-18 NPT female to
R3/8 male.
FEATURES
Splash-proof enclosure (IP54)
SPDT contacts are provided as standard on single pressure control
Trip-free manual reset
APPLICATION
The series P48 pressure controls are designed for high/low cut-out control on steam,
air or (hot) water applications. Also for non-combustible gases which are not harmful
to the materials in contact with these mediums. On steam applications a steam trap is
recommended (see Accessories).
Ordering
Codes
Range
(bar)
Differential
(bar)

Style Notes
List
Price
P48AAA-9110 0-1 0.16-0.55
29a
A
136
P48AAA-9120 0.2-4 0.25-0.8 93
P48AAA-9130 -0.2-+10 1-4.5 93
P48AAA-9140 1-16 1.3-2.5 93
P48AAA-9150 3-30 3-12 A, B 116
P48BEA-9140* 4-16 - C 128
* Quantity orders only See page 42 for Style references
Switch Action - SPDT, Open high
Switch Rating - 16(10)A, 220-400Vdc, 12W (pilot duty only)
Pressure Connection - G 3/8 male
Size - 146 x 88 x 53mm
Notes:
A = Automatic Reset
B = Stainless steel bellows
C = Manual Reset
P735 Series
Single Pressure Switches
This series of pressure controls may be used for control
functions or limit functions, depending on model number.
All models are provided with alarm contacts. All standard
models have phosphor bronze bellows and brass pressure
connections. Models for use with ammonia are provided
with stainless steel bellows and connectors.
FEATURES
SPDT contacts are provided as standard on single pressure controls
Trip-free manual reset
APPLICATION
These pressure controls are designed for use in a variety of applications involving
refrigeration high or low pressure. Models supplied have a whole range design,
enabling them to be used with all non-corrosive refrigerants which are within the
operating range of the control. They may also be used for other high or low pressure
applications such as air, water etc. Models which can be used with ammonia are
included in the program.
(Continued next column)
P736 Series
Dual Pressure Switches
The P736 series pressure controls may be used for
control functions or limit functions, depending on
model number. All models are provided with alarm
contacts (except P736ALA). All standard models
have phosphor bronze bellows and brass pressure
connections. Models for use with ammonia are
provided with stainless steel bellows and connectors.
FEATURES
Trip-free manual reset
Separate alarm contacts for both low pressure and high pressure cut-out
(except P736ALA)
APPLICATION
These dual pressure controls are designed for use in a variety of applications
involving refrigeration high or low pressure. Models supplied have a whole range
design, enabling them to be used all non-corrosive refrigerants which are within the
operating range of the control. They may also be used for other high or low pressure
applications such as air, water etc. Models which can be used with ammonia are
included in the program.
Ordering
Codes
Left Side (bar) Right Side (bar)

Style
List
Price
Range Diff. Range Diff.
For Non-corrosive Refrigerants (LP: 22 bar, HP: 33 bar max.)
P736LCA-9300
-0.5-+7
0.5-3
3-30
3 (fixed)
5 42
P736LCA-9400 30 58
P736MCA-9300
Man. Res.** 5
72
P736PGA-9300 Man. Res.* 75
For Fan Cycling - Air-cooled Condensers, Non-corrosive (HP/HP: 30 bar max.)
P736ALA-9351 3.5-21 1.8 (fixed) 3.5-21 1.8 (fixed) 5 50
(Continued next column)
Ordering
Codes
Range
(bar)
Differential
(bar)
Switch
Action
(wire diag.)
Max.
Bellows
Pressure

Style
List
Price
For Water
P735AAA-9200 -0.2-+10 1-4.5
1
15
***
63
P735AAA-9201 -0.5-+7 0.5-3 22 62
For Non-corrosive Refrigerants (Alerter, safety pressure limiter)
P735AAA-9300
-0.5-+7 0.5-3
1
22
5 28
P735AAA-9400 30 48
P735AAA-9301 -0.2-+10 1-4.5 15
5
28
P735AAA-9350 3-30 3-12
2
33 28
P735AAA-9351 3.5-21 2.1-5.5 30 49
P735BCA-9300 -0.5-+7 Man. res.** 1 22 32
P735BEA-9350 3-30 Man. res.* 3 33 30
For Non-corrosive Refrigerants
P735AAW-9300 -0.5-+7 0.6 to 3 1 20
5
49
P735AAW-9350
3-30 3.5 to 12 2 33
43
P735AAW-9850 28 63
P735BCB-9300 -0.5-+7 Man. res.** 1 20
5
49
P735BEB-9350
3-30 Man. res.* 3 33
46
P735BEB-9850 28 63
Notes: See page 42 for Style reference
* Resetable at 3 bar below cut-out point
** Resetable at 0.5 bar above cut-out point
*** Special pressure connection G 1/4 female
100 kPa = 1 bar = 14.5 psi
Contact Rating - SPDT
Size - 92 x 70 x 51mm
Protection Class - IP30
SENSORS / THERMOSTATS (cont)
27
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
P77 Series
Single Pressure Switches (IP54)
These controls may be used for control functions or
limit functions, depending on model number. All models
are provided with alarm contacts. All standard models
have phosphor bronze bellows and brass pressure
connections. Models for use with ammonia are provided
with stainless steel bellows and connectors. Devices
conforming to PED 97/23/EC Cat. IV (HP models) have the
fail-safe function with double bellows.
FEATURES
Splash-proof enclosure (IP54)
SPDT contacts are provided as standard on single pressure controls
Trip-free manual reset
APPLICATION
These pressure controls are designed for use in a variety of applications involving
refrigeration high or low pressure. Models supplied have a whole range design,
enabling them to be used with refrigerants R22, R134A, R404A, R410A and all other
non-corrosive refrigerants which are within the operating range of the control. They
may also be used for other high or low pressure applications such as air, water etc.
Models which can be used with ammonia are included in the program. Also models
tested and approved to PED 97/23/EC Cat. IV (supersedes DIN and TUV approval) are
included in the program.
Ordering
Codes
Range
(bar)
Diff.
(bar)
Wiring\
Action

Style Refr. Notes


List
Price
P77AAA-9300 -0.5-+7 0.5-3
1
5
non-
corr.
-
53
P77AAA-9301 -0.2-+10 1-4.5 53
P77AAA-9302 -0.3-+2 0.4-1.5 53
P77AAA-9350 3-30 3-12
2
53
P77AAA-9351 3.5-21 2-5.5 53
P77AAA-9400 -0.5-+7 0.5-3 1
30 - A
53
P77AAA-9450 3-30 3-12
2
53
P77AAA-9451 3.5-21 2-5.5 53
P77AAA-9700 -0.5-+7 0.5-3
15 NH3 -
90
P77AAA-9750 3-30 3-12 90
P77AAA-9800 -0.5-+7 0.5-3 1
28
non-
corr.
B
63
P77AAA-9850 3-30 3-12 2 63
See page 42 for Styles and Wiring Diagrams
(Continued next column)
Ordering
Codes
Left Side (bar) Right Side (bar)

Style
List
Price
Range Diff. Range Diff.
For Non-corrosive Refrigerants (LP: 22 bar, HP: 33 bar max.)
P736LCW-9300
-0.5-+7
0.6-3
3-30
3 (fixed)
5 79
P736LCW-9800 28 84
P736MCB-9300
Man. Res.** 5
84
P736MCS-9300 79
P736PGB-9300 Man. Res.* 84
Manual Reset, Safety Pressure Limiter (HP/HP: 30 bar max.)
P736PLM-9370 3-30 Man. Res.** 3-30 Man. Res.** 5 86
Notes: See page 42 for Styles and Wiring Diagrams
* Resetable at 0.5 bar above cut-out point
** Resetable at 3 bar below cut-out point
100 kPa = 1 bar 14.5 psi
Contact - SPST
Size - 132 x 77 x 51mm
Protection Class - IP30
Ordering
Codes
Range
(bar)
Diff.
(bar)
Wiring\
Action

Style Refr. Notes


List
Price
Automatic Recycle (Alerter, including lockplate assembly)
P77AAW-9300 -0.5-+7 0.5-3 1
-
non-
corr.
-
65
P77AAW-9350 3-30 3.5-12
2
59
P77AAW-9355 3-42 4-12 5 68
P77AAW-9700 -0.5-+7 0.5-3 1
15 NH3 -
108
P77AAW-9750 3-30 3.5-12 2 155
P77AAW-9800 -0.5-+7 0.5-3 1
28
non-
corr.
B
65
P77AAW-9850 3-30 3.5-12
2
79
P77AAW-9855 3-42 4-12 - 83
Manual Reset (LP)
P77BCA-9300
-0.5-+7 - 1
5
non-
corr.
- 59
P77BCA-9400 30 A 71
P77BCA-9700 15 NH3
-
98
P77BCB-9300 5
non-
corr.
72
P77BCB-9800 28 B 73
Manual Reset (HP)
P77BEA-9350
3-30 - 3
5
non-
corr.
- 52
P77BEA-9450 30 A 67
P77BEA-9750 15 NH3 - 99
Limiter, including lockplate assembly
P77BEB-9350 3-30
- 3
5
non-
corr.
-
70
P77BEB-9355 3-42 89
P77BEB-9750
3-30
15 NH3 147
P77BEB-9850
28
non-
corr.
B 69
P77BEB-9855 3-40 - 93
Safety pressure limiter, including lockplate assembly
P77BES-9350
3-30 - 3
5
non-
corr.
-
72
P77BES-9750 15 NH3 88
P77BES-9850 28
non-
corr.
B 93

See page 42 for Styles and Wiring Diagrams
Notes:
A = Solder connection 1/4 ODF
B = Solder connection 6mm ODM
Contact - SPST
Size - 88 x 80 x 53mm
Protection Class - IP54
28
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
P78 Series
Dual Pressure for IP54 Applications
The P78 series pressure controls may be used for
control functions or limit functions, depending on
model number. All models are provided with alarm
contacts (except P78ALA). All standard models
have phosphor bronze bellows and brass pressure
connections. Models for use with ammonia are
provided with stainless steel bellows and connectors.
Devices conforming to DIN 32733 have a double bellows
on the high pressure versions.
FEATURES
Splash-proof enclosure (IP54)
Trip-free manual reset
Patented separate alarm contacts for both low pressure and high pressure cut-out
(except P78ALA)
APPLICATION
These pressure controls are designed for use in a variety of applications involving
refrigeration high or low pressure. Models supplied have a whole range design,
enabling them to be used with refrigerants R22, R134A, R404A, R410A and all other
non-corrosive refrigerants which are within the operating range of the control. They
may also be used for other high or low pressure applications such as air, water etc.
Models which can be used with ammonia are included in the program. Also models
tested and approved to PED 97/23/EC Cat. IV (supersedes DIN and TUV approval) are
included in the program.
Ordering
Codes
Range
(bar)
Diff.
(bar)
Wiring/
Action

Style Refr. Notes


List
Price
Automatic Recycle
P78LCA-9300
-0.5-+7 LP
3-30 HP
0.5-
3 LP
4
5 non-corr. - 72
P78LCA-9400 30
-
A 72
P78LCA-9500 35 B 90
P78LCA-9700 15 NH3 - 156
Automatic Recycle, Technical Inspection Agency
P78LCW-9300
-0.5-+7 LP
3-30 HP
0.5-
3 LP
4
5
non-corr. - 173
P78LCW-9302*
-
C 125
P78LCW-9800
28
D 89
P78LCW-9801* E 134
Manual Reset (HP)
P78MCA-9300
-0.5-+7 LP
3-30 HP
0.5-
3 LP
4
5
non-corr.
- 75
P78MCA-9400 30 A 75
P78MCA-9700 15 NH3 - 161
Manual Reset (LP)/Auto. Reset (HP)
P78PGA-9300
-0.5-+7 LP
3-30 HP
- 4
5
non-corr.
- 84
P78PGA-9400 30 A 99
P78PGA-9700 28 NH3 - 187
Manual Reset (LP/HP)
P78PGB-9300
-0.5-+7 LP
3-30 HP
- 4
5
non-corr.
- 106
P78PGB-9800 28 D 96
Manual Reset (HP) Limiter, including lockplate assembly
P78MCB-9300
-0.5-+7 LP
3-30 HP
0.5-
3 LP
4
5
non-corr.
- 90
P78MCB-9800 28 D 96
Manual Reset (HP) Safety Pressure Limiter, including lockplate assembly
P78MCS-9300
-0.5-+7 LP
3-30 HP
0.5-
3 LP
4 5 non-corr. - 85
Manual Reset (HP/HP) Safety Pressure Limiter, including lockplate assembly
P78PLM-9350
3-30 LP
3-30 HP
- 5
5
non-corr.
- 116
P78PLM-9850 28 D 138
Dual Fan Cycling Control
P78ALA-9351
3.5-21 LP
3.5-21 HP
- 6
5
non-corr.
- 93
P78ALA-9451 30 A 90
See page 42 for Styles and Wiring Diagrams
* Quantity orders only
(Continued next column)
Notes:
A = Solder connection 1/4 ODF
B = With 90cm capillary pressure connection
C = Gold plated contacts
D = Solder connection 6mm ODM
E = Gold plated contacts, fixed settings LP 0.3 bar; HP 22.5 bar
Contact - SPST
Size - 88 x 80 x 53mm
Protection Class - IP54
(Continued next column)
P100 Series
Direct Mount Pressure Switches
These encapsulated, non-adjustable, direct mount pressure controls typically used for
low and highpressure cut-outs for OEM applications. The P100 series are produced
according to switchpoint requirements of customers.
The small dimensions, weight and protection class makes the P100 series applicable
for use without the need of additional mounting brackets. They can be used for all
non-corrosive refrigerants like R134a; R22; R404, R410A and others.
FEATURES
Compact size and light weight
Encapsulated, dust tight switch IP67
Broad variety of electrical and pressure connections.
APPLICATIONS
Computer room air-conditioning
Refrigeration/ air-conditioning condensers
Commercial refrigeration
Ice machines
Food service equipment
Ordering
Codes Appl. Refr.
P (bar) P Toler. (bar)
Notes
List
Price
Open (Close) Open (Close)
Auto Reset Models
P100AP-300D
Low
Press.
Norm.
Open
R134A 2.5 (4)
0.5 (0.5)
A, D 18
P100AP-301D B, D 12
P100AP-302D R407C 4 (6) A, D 12
P100AP-306D R404A 0.3 (2.8) 0.4 (0.4) A, D 12
P100AP-308D
-
0.5 (1.5)
0.3 (0.3)
A, C 11
P100AP-309D
0.7 (2.2)
A, F 12
P100AP-310D A, E 11
P100CP-102D
High
Press.
Norm.
Closed
R134A 16 (11)
0.7 (1.4)
A, D 15
P100CP-103D B, D 18
P100CP-104D R407C 24 (18)
A, D
12
P100CP-106D
R404A 28 (23)
0.7 (0.7)
12
P100CP-107D B, D 12
P100CP-108D R410A 38 (28) A, D 12
P100CP-110D
-
27.6 (20.7) A, C 9
P100CP-111D 26 (20) A, D 18
Notes:
A = 1/4 SAE Fem Flare
B = 50mm straight, 6mm dia. x 7mm reduced end, copper clad brazing tube (TIF5)
C = Faston termination
D = 2 metre cable
E = 3 metre cable
F = 1.2 metre cable
FEATURES
Compact size and light weight
Encapsulated, dust tight switch IP67
Manual reset models have a trip-free design
Models with gold-plated contacts available
Broad variety of electrical and pressure
connections
Manual Reset Models
Auto Reset Models
SENSORS / THERMOSTATS (cont)
29
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
Ordering
Codes Appl. Refr.
P (bar) P Toler. (bar)
Notes
List
Price
Open (Close) Open (Close)
Manual Reset Models
P100DA-66D
High
Pressure
R134A 16 (-)
0.7 (-)
A, D 15
P100DA-67D B, D 18
P100DA-68D
R407C 26 (-)
A, E 20
P100DA-69D B, E 20
P100DA-70D
R404A 28 (-)
A, E 17
P100DA-71D B, E 20
P100DA-72D
R410A 38 (-) 1.0 (-)
A, D 18
P100DA-73D B, D 18
P100DA-74D R407C 26 (-)
0.7 (-)
A, F 16
P100DA-75D
R410A 42 (-)
A, D 18
P100DA-76D B, D 18
Heavy Duty Models - Auto Reset
P100EE-17D
HP
Norm.
Closed
R404A 20 (25)
1.0 (1.0) A, H
26
P100EE-18D R134A 15 (11) 22
P100EE-60D
R404A 28 (21) 0.7 (0.7)
A, D 19
P100EE-61D B, D 23
P100EE-68D R134A 3 (25) 0.35 (0.35) A, G 21
Notes:
A = 1/4 SAE Fem Flare
B = 50mm straight, 6mm dia. x 7mm reduced end, copper clad brazing tube (TIF5)
C = Faston termination
D = 2 metre cable
E = 3 metre cable
F = 1.2 metre cable
G = 1.8 metre cable
H = 1.5 metre cable
General Accessories
for Pressure Switches
Ordering Codes Description Price
BKT034N602R Mounting bracket + screws for P35AC transducer 5
210-25R Mounting bracket for P20/P35 (single) 4
WRN12-1 Wrench P20/P21 15
210-604R Terminal cover P20/P21 (50 off) 15
BKT024N002R Mounting bracket for P233 4
FTG015N602R Duct mounting kit staight 26
FTG015N603R Duct mounting kit bent 26
GMT008N600R Duct kit for P233, self locking grommet and tubing 10
CNR003N001R Connector 6mm for P77/P78 11
CNR003N002R Connector 8mm for P77/P78 11
CNR012N001R Adapter R3/8 female to 1/4-18 NPT male for P48 17
CNR013N001R Adapter R 3/8 female to 1/4-18 NPT female for P48 20
TBG16A-600 Steam trap assembly P48 30
KIT023N600 Locking kit for P48, P77/P78 - for field installation 4
KIT031N600
Valve depressors for conversion style 13 - style 45a
(100 off-1 box)
86
KIT034N600 Seal rings for style 50/51 (250 off-1 box) 109
271-51L
Mounting bracket for P28, P45, P48, P74, P77/P78
(50 off)
4
SEC002N600 Capillary kit, 90cm, 2 x style 13 (100 off-1 box) 8
SEC002N602

90cm, style 13 - style 45a (100 off-1 box) 11


SEC002N606

200cm, style 13 - style 45a (75 off) 14


SEC002N607

200cm, 2 x style 13 (75 off) 12


SEC002N616

90cm, style 13 - cap. (150 off-1 box) 8


SEC002N617

100cm, style 13 - style 13 (100 off-1 box) 10


SEC002N621

90cm, style 34 - style 34 (100 off-1 box) 8


SEC002N622

90cm, style 50 - style 50 (100 off-1 box) 13


(Continued next column)
H735 Series
Synthetic Flexible Hose
The synthetic hoses consist of a seamless PA
compound inner layer reinforced with a braided layer
of high performance synthetic fibre. This reinforcement
is protected by an oil, weather and abrasion resistant
Polyester Elastomer Compound.
The standard assembly length is 0.9 metre with one straight
and one elbow 90 degree hose fitting. The fitting connection is 1/4 metal tube with
7/16-20 UNF swivel nut connection suitable for 1/4 SAE male flare. Other lengths
and/or fitting connections configurations (Style 50, 51 straight or elbow) are available
on request (quantity orders only).
FEATURES
Low minimum bend radius (30mm)
One straight and one 90 elbow pressure connection
Polyester Elastomer Compound construction
High pressure safety ratio
Low effusion
APPLICATION
These synthetic hoses are designed for pressure measuring connections. They
provide, for example, a very flexible connection between a refrigerant compressor
and pressure controls. The hoses can be used for all non-corrosive refrigerants
including R134a, R22, R404a, R407c and R410A with pressures within the maximum
pressure range of the hose. Hoses are tested with common compressor oils in
combination with above mentioned refrigerants.
Ordering
Codes Pressure Connection Hose Length
List
Price
H735AA-90D Straight x 90 elbow 90cm 26
Notes:
1. Minimum shipping quantity 100 pieces
2. Fitting connection; 1/4 metal tube with 7/16-20 UNF swivel nut connection
suitable for 1/4 SAE male flare
Ordering Codes Description Price
SEC002N624 Capillary kit, 200cm, style 50 - style 50 18
SEC002N626

90cm, style 50 - style 51 11


SEC002N627

200cm, style 50 - style 51 14


SEC002N628

300cm, style 50 - style 51 16


SEC002N631

50cm, style 13 - style 34 8


30
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
Pressure Transducers
P35 Series
Mechanical Transducers
The P35 is a single pressure input fan speed
controller for air cooled condensers. The controller
varies the fan speed by directly sensing the pressure
changes in a refrigerant circuit. The setpoint of each
pressure transducer can be separately adjusted.
The controller selects the input with the greatest cooling
demand to control the fan speed.
The controllers can be used in non corrosive refrigerant
systems and vary the supply voltage to the motor from 45% to
95% of the supplied voltage using the phase cutting principle. If the pressure drops
below the adjusted setpoint minus the proportional band, the output to the motor is
zero volt or the adjusted min. speed setting.
This provides speed variation of permanent split capacitor or shaded pole motors
which do not draw more than 3A (rms) full load current. The motor manufacturer
should have approved his product for this speed control principle. It is recommended
to confirm with the electric motor manufacturer, that the motor can be used with a
controller, using the phase cutting principle for speed variation.
FEATURES
Condenser pressure control by fan speed variation
Pressure input / dual pressure input (BR models)
Transducers with proven reliability
Built-in suppression filter
Adjustable minimum speed or cut-off selection
Ordering
Codes Range
Setting
(bar)

Style Notes
List
Price
Replacement Pressure Transducers for P215 version (300 ohm)
P35AC-9100
14-24 16
45A
-
129
P35AC-9202
47
110
P35AC-9203 8-14 10 160
P35AC-9500 14-24 16
50
137
P35AC-9501 8-14 10 125
P35AC-9512 22-42 30 A 168
P35AC-9600 14-24 16
13 B
129
P35AC-9601 8-14 10 96
Replacement Pressure Transducers for P255 version (100 ohm)
P35AC-9200 14-24 16
47
-
110
P35AC-9201 8-14 10 160
P35AC-9106 3.5-10
16
45A 125
P35AC-9604 8-14 13 132
P35AC-9505 14-24 10
50
141
P35AC-9506 22 16 139
P35AC-9511 8-14 30 A 162
Replacement Pressure Transducers for P255 version (500 ohm)
P35AC-9200 14-24 16
50
C 160
P35AC-9201 22-40 30 D 160
Notes: See page 42 for Style references
A = For R410A applications
B = Also used for replacement P15/P215 series fan speed controllers
C = Special 500 K for P215LR-400V version
D = Special 500 K version for R410A applications
Capillary Length - 90cm
P499 Series
Electronic Transducers
The P499 Series is a new global Pressure Transducer
with an excellent price performance ratio. The P499
exceeds the latest industrial CE/UL requirements
including surge protection, and is over voltage
protected in both positive and reverse polarity.
The P499 is designed to produce a linear analogue signal based on the sensed
pressure. The pressure port is machined from a solid piece of 17-4PH stainless steel.
There are no O-rings or welds that are exposed to the pressure media. This results in
a leak proof, all metal sealed pressure system which withstand more than 10 million
pressure cycles without failure.
FEATURES
Single-piece machined steel pressure port
Environmentally sealed electronics
Reliable, repeatable performance and long operating life
Slender body design
Ordering
Codes
Range
(bar) Output Supply
Press
Connection Note
List
Price
P499-ABS-401C -1-+8
0.4-20
mA
9-32Vdc
Male
A
66
P499-ABS-404C 0-30 66
P499-ACS-401C -1-+8
Female
47
P499-ACS-404C 0-30 38
P499-VBS-401C -1-+8
0-10Vdc 12-30Vdc
Male
55
P499-VBS-404C 0-30 55
P499-VCS-401C -1-+8
Female
51
P499-VCS-404C 0-30 42
Notes:
A = Maximum (short) overpressure: Range -1-8 bar: 16 bar Range 0-30 bar:
60 bar Range 0-50 bar: 100 bar.
Can be used with all media which are compatible with stainless steel type
17-4PH.
Accuracy: +/- 0.25% FS BFSL
Total Error: +/- 1% FS
SENSORS / THERMOSTATS (cont)
31
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
Ordering
Codes
NTC K10
Sensor
Setpoint
Range Config. Outputs
Power
Mod.+
List
Price
Local Controllers (3-speed Fan Output) and used with ES-8940 Module (cont)
TC-8902-1032-WK
- 12-28C
2 pipe

1 x 0-10Vdc A
84 1 x DAT 230V B
1 x DAT 24V C
TC-8907-1032-WK 1 x Relay D 120
TC-8902-2032-WK
4 pipe
2 x 0-10Vdc A 73
TC-8907-2032-WK 2 x DAT 230V B 116
TC-8942-2041-WK*

+/-
**
2 x DAT 24V C 82
TC-8947-2041-WK* 2 x Relay D 131
Notes:
* only in connection with ES-8940-4130-WK
** +/- on local controller TC-89, 12-28C on ES-8940 central setpoint module
Relay 3A, 230V/24V
With changeover
Size - 80 x 80 x 33mm
Protection Class - IP30
+ POWER MODULES
Ordering Codes Description Price
PM-8902-0500 (A) - 1 x 0-10Vdc Output 103
PM-8905-0300 (B) - 1 x DAT 230V Output 82
PM-8905-0500 (C) - 1 x DAT 24V Output 96
PM-8907-0300 (D) - 1 x Relay 3A 230V/24V Output 70
TC-8900, PM-8900 & ES-89xx Series
Room Controllers
This family of analogue controllers is designed for control
of fan coils with 2-pipe, 2-pipe with change-over, 2-pipe
with electrical coil or 4-pipe configurations.
For applications without fan speed control the family
includes stand alone units (TC-890x), local controllers
(TC-893x) with remote setpoint module (ES-8930) and
local controllers (TC-894x) with central setpoint
module (ES-8940).
For applications with fan speed control the family includes the PM-8900
power modules in connection with TC-894x with or without central setpoint
module (ES-8940).
FEATURES
2-pipe, 2-pipe with change-over, 2-pipe with electrical coil or 4-pipe
configurations with and withoput 3-speed fan override
24Vac and 240Vac power modules
Ordering
Codes
NTC K10
Sensor
Setpoint
Range
Outputs List
Price
PAT 0-10V DAT On/Off
Stand-alone Controllers
TC-8903-1131-WK

12-28C
1 - - - 97
TC-8901-2131-WK - 2 - - 77
TC-8904-2131-WK - - 2 - 88
TC-8906-2131-WK - - - 2 131
TC-8903-1132-WK
-
1 - - - 99
TC-8901-2132-WK - 2 - - 81
TC-8904-2132-WK - - 2 - 76
TC-8906-2132-WK - - - 2 77
TC-8903-1151-WK

0-40C
1 - - - 139
TC-8903-1152-WK - 1 - - - 114
Stand-alone Controllers with 0-10V input
TC-8903-1183-WK
- 0-100%
1 - - - 137
TC-8901-2183-WK - 2 - - 137
Local Controllers used with ES-8930 Remote Setpoint Module
TC-8933-1112-W
- -
1 - - - 130
TC-8931-2112-W - 2 - - 77
TC-8936-2112-W - - - 2 81
ES-8930-3031-WK

12-28C - - - - 99
Local Controllers used with ES-8940 Central Setpoint Module
TC-8943-1141-WK

+/
1 - - - 106
TC-8941-2141-WK - 2 - - 85
TC-8944-2141-WK - - 2 - 103
TC-8946-2141-WK - - - 2 83
ES-8940-4130-WK - 12-28C - - - - 118
Ordering
Codes
NTC K10
Sensor
Setpoint
Range Config. Outputs
Power
Mod.+
List
Price
Local Controllers (3-speed Fan Output) and used with ES-8940 Module
TC-8902-1031-WK

12-28C
2 pipe

1 x 0-10Vdc A
75 1 x DAT 230V B
1 x DAT 24V C
TC-8907-1031-WK 1 x Relay D 131
TC-8902-2031-WK
4 pipe
2 x 0-10Vdc A
81 2 x DAT 230V B
2 x DAT 24V C
TC-8907-2031-WK 2 x Relay D 96
(Continued next column)
Room Controllers
32
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
(Continued next column)
Capillary and Space Thermostats
A19 Series
Capillary and Space, IP30 & IP65
These thermostats are available with fixed or adjustable
differential. The various control ranges cover a broad range of
temperature applications with a minimum number of models.
On request a built-in high or low limit stop is possible and can
be adjusted quickly and easily in the field. All models have a
universal way of adjustment. For this purpose a knob and sealing
cap are enclosed.
FEATURES
Liquid filled sensing element
Dust tight PENN switch
Trip free manual reset
APPLICATION
These thermostats are designed for refrigeration, cooling, heating, ventilation and
air-conditioning applications. Standard models are provided for remote sensing or
room sensing. Models with manual reset are available for low or high limit functions.
Ordering
Codes
Range
(C)
Diff.
(K)**

Style
Capillary
(Bulb)
SPDT
Switch* Notes
List
Price
Capillary Thermostats - IP30
A19AAC-9005 -5-+28 2
1b
2m (135mm) OL
-
43
A19AAC-9009 40-120 3.5 2m (100mm) OH 38
Capillary Thermostat, Lock-out Low with Manual Reset - IP30
A19ACC-9100 -35-+10 6
1b
2m (110mm)
OL -
53
A19ACC-9101 -5-+28 4 2m (135mm) 62
Capillary Thermostats - IP65
A19AQC-9101 -5-+5
2
1a 2m (80mm)
OL
A 46
A19AQC-9102 -5-+28 1b 2m (135mm) B 49
A19AQC-9200 -5-+55 2.5 2 - - 102
* Auto recycle, SPDT, 8A See page 42 for Style references
** Fixed OL = Open low, OH = Open high
Notes:
A = 5A switch, ice bank control, bulb dia. 9.3mm, case compensation, concealed
scale, screwdriver adjustment, scale calibrated at increasing temperature.
B = 8A switch, calibrated and set at 2C, case compensation, pointer adjust, PG16
connect, 1/2- 14NPT WELL connector.
Other styles and specifications available. Please contact the Sales Support Team.
Style 1b Type
SENSORS / THERMOSTATS (cont)
Ordering
Codes Output Control
Fan
Control Model Type Appl.
List
Price
For BACnet

MS/TP Communication
TEC2645-2 1 x 0-10Vdc 1 Speed
Commercial
A 322
TEC2616-2 2 x ON/OFF
1, 2 or 3
Speed
B
463
TEC2626-2 2 x ON/OFF or Floating 485
TEC2646-2 2 x 0-10Vdc 518
TEC2616H-2 2 x ON/OFF
Hospitality
463
TEC2626H-2 2 x ON/OFF or Floating 432
TEC2646H-2 2 x 0-10Vdc 519
TEC2627-2 2 x ON/OFF or Floating
-
Commercial*
C
322
TEC2647-2 2 x 0-10Vdc 339
TEC2601-2 Single Stage
On, Off
or Auto
D 321
TEC2602-2 Heat Pump E 415
TEC2603-2 Multi Stage F 453
TEC2604-2 Economiser G 479
For N2 Open Communication
TEC2145-2 1 x 0-10Vdc 1 Speed
Commercial
A 304
TEC2116-2 2 x ON/OFF
1, 2 or 3
Speed
B
430
TEC2126-2 2 x ON/OFF or Floating 463
TEC2146-2 2 x 0-10Vdc 463
TEC2116H-2 2 x ON/OFF
Hospitality
446
TEC2126H-2 2 x ON/OFF or Floating 463
TEC2146H-2 2 x 0-10Vdc 500
TEC2127-2 2 x ON/OFF or Floating
-
Commercial*
C
304
TEC2147-2 2 x 0-10Vdc 315
TEC2101-3 Single Stage
On, Off
or Auto
D 309
TEC2102-3 Heat Pump E 411
TEC2103-3 Multi Stage F 450
TEC2104-3 Economiser G 479
For LONWORKS

Communication
TEC2245-2 1 x 0-10Vdc 1 Speed
Commercial
A 352
TEC2216-2 2 x ON/OFF
1, 2 or 3
Speed
B
483
TEC2226-2 2 x ON/OFF or Floating 509
TEC2246-2 2 x 0-10Vdc 545
TEC2216H-2 2 x ON/OFF
Hospitality
493
TEC2226H-2 2 x ON/OFF or Floating 455
TEC2246H-2 2 x 0-10Vdc 545
TEC2227-2 2 x ON/OFF or Floating
-
Commercial*
C
356
TEC2247-2 2 x 0-10Vdc 387
TEC2201-3 Single Stage
On, Off
or Auto
D 367
TEC2202-3 Heat Pump E 447
TEC2203-3 Multi Stage F 486
TEC2204-3 Economiser G 514
Ordering
Codes Output Control
Fan
Control Model Type Appl.
List
Price
For LONWORKS

Communication (cont)
TEC2261-3 Single Stage
-
Commercial
**
D 491
TEC2262-3 Heat Pump E 546
TEC2263-3 Multi Stage F 546
TEC2264-3 Economiser G 584
* Non programmable ** LonWorks programmable
Applications:
A = Commercial two-pipe equipment, cabinet unit heaters, and perimeter
heating/cooling
B = Two or four-pipe fan coil equipment
C = Two or four-pipe equipment, hydronic reheat valve control, and pressure
dependent VAV with or without local reheat
D = Fan coil unit, unit heaters, and single-stage packaged heating/cooling equipment
E = Heat pump with up to three heating/two cooling stages
F = Multi-staged packaged heating/cooling stages
G = Packaged rooftop units with economisers
Supply Voltage - 5Vdc +/-10%, 24Vac +10%/-15%
Size - 125 x 86 x 29mm
ACCESSORIES
Ordering Codes Description Price
SEN-600-1 Remote NTC K10 Room Temp. Sensor in TEC2000 Style 59
SEN-600-4
Remote NTC K10 Room Temperature Sensor with
occupancy override in TEC2000 Style
63
TEC-2000 Series
Room Controllers
The TEC2000 Series is a networked small equipment
controller providing N2, BACnet

MS/TP and LonWorks


communicating options. It offers equipment control from a
single product: thermostat, controller and temperature sensor.
The TEC Series staged controllers can be used with rooftop
units (with and without Economisers), heat pumps and single-
and multi-stage heating/cooling equipment.
Models are available for commercial and hospitality applications, including cabinet unit
heaters, perimeter heating/cooling, zoning and fan coil units. They provide control of
various two- and four-pipe fan coil equipment, have options for one- to three-speeds
of fan control and offer additional application flexibility by providing advanced control
signals proportional 0-10Vdc, ON/OFF or Floating.
All models have two configurable binary inputs for advanced functions and feature
over 20 configurable parameters, which enable the thermostat to be customised
for any application. The thermostats feature a two-line, eight-character backlit LCD
display with status texts in English. Models with display texts in other languages are
available on special requests.
33
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
A25 Series
Rod and Tube Sensing Element, IP30
A rod and tube type sensing element actuate
the switch contacts. Main contacts (1-2)
are normally closed, and open when the
temperature at the element rises to the dial
setpoint. Contacts are re-closed only by operation of the
reset lever. The reset lever is trip-free and cannot be used to
block contacts in a closed position.
FEATURES
Rod and tube type of element
Adjustable duct mounting flange
Trip-free manual reset
Dust-tight PENN switch
APPLICATION
These warm air limit controls lock out on a temperature increase to the control
setpoint. Manual reset is required to re-close the electrical contacts. A typical
application is to stop air-conditioning or ventilating fans in the event of excessive
return air temperature, as from a fire.
Ordering
Codes Range (C) Switch. 8A, Manual Reset
List
Price
A25CN-9001 0-100 SPDT, Open High 147
Note: Visible scale, knob adjustment, NEMA 1 enclosure, with flange
for duct mounting.
IP30 Model
Style 1b and 3
IP65 Model
Style 1b
A28 Series
2-Stage Thermostats, IP30 & IP65
Controls are compact with fixed differential
per stage and (on most models) adjustable
differential between stages. Liquid filled
element provides wide range, constant
differential over whole range and no influence
from barometric pressure. Since the bulb
contains the major portion of the total fill the
thermostat may by considered as cross-
ambient, capillary and cup temperature
variations affect the operating point only
slightly due to the small amount of
fill they contain.
For quantity orders it is possible to have the
below stated optional constructions:
- Without case and cover for panel mounting
- Close differential per stage
- Different capillary lengths
All standard IP30 enclosure models have a universal way of adjustment. For this
purpose a knob and sealing cap are enclosed.
FEATURES
Liquid filled sensing element
Dust tight PENN switch
IP65 protection class models available
Front adjustment
APPLICATION
These thermostats are designed for various types of heating, cooling, ventilation,
or air-conditioning applications. All models have two SPDT switches providing the
following control possibilities:
- 2 stage heating
- 2 stage cooling
- Heating/cooling with automatic changeover
Ordering
Codes
Range
(C)
Diff. (K)

Style
Capillary
(Bulb mm) Switch Notes
List
Price Stg Bet
IP30 Thermostats
A28AA-9006 -35-+10 2
1-4
1b
2m (110mm)
OL A
150
A28AA-9007
-5-+28
1.5
2m (135mm) 137
A28AA-9106 5m (135mm) 257
A28AA-9113 0- 43 3 -
OH
A, B 164
A28AA-9118 1-60 2 1b 3m (115mm) A, C 144
(Continued next column)
A36 Series
3 and 4-Stage Thermostats
Models are available in open construction for panel
mounting. Single knob adjustment moves the entire
staging band up and down within the range of the
control. The differential on each stage and sequencing
between stages are factory set.
This permits the OEM to completely engineer the cycling
of their equipment without the hazard of field mis-
adjustments and erratic sequencing.
FEATURES
Dust-tight SPDT switches
Cushion mounted
Operation from a single, liquid filled element
Case compensation standard on all models
APPLICATION
Designed for multi-stage thermostatic operation of electrically
controlled equipment such as:
Packaged liquid chillers
Heat pumps
Electric duct heaters
Computer room air-conditioners
Ordering
Codes
Range
(C)
Adjust
Code
Capillary
(Bulb) SPDT* Notes
List
Price
3-Stage Thermostats
A36AGA-9101
-18-+20 B1
5m (125mm)
5A
A
270
A36AGA-9102 3.5m (125mm) 247
A36AGA-9103 15-35 C1 3.5m (140mm) 217
A36AGB-9103 -18-+20 B2 3.5m (125mm) 3A 225
4-Stage Thermostats
A36AHA-9105 -18-+20
B1
3.5m (125mm)
5A A
241
A36AHA-9107 -16-+20 5m (125mm) 303
A36AHA-9108 15-35 C1 3.5m (140mm) 283
A36AHB-9103 10-95 D2 3m (100mm)
3A
B 287
A36AHB-9104
-18-+20
B2
3.5m (125mm) A 283
A36AHB-9105 5m (125mm) C 303
A36AHB-9109 -15-+30 5m (110mm) D 390
Notes:
* Auto recycle
A = Armoured PVC capillary
B = Max. bulb temp. 115C
C = Braided copper capillary
D = Max. bulb temp. 75C
Switch Contact - SPDT
Size - 173 x 69 x 62mm
Protection Class - IP20
4-Stage Type
Ordering
Codes
Range
(C)
Diff. (K)

Style
Capillary
(Bulb) Switch Notes
List
Price
Stg Bet
IP65 Thermostats
A28QA-9101 5 -50
2
4
1b
2m (110mm)
OL
D, E 257
A28QA-9110 -35-+10
1-4
-
167
A28QA-9111 -5-+28 1.5 2m (135mm) 177
A28QA-9114 -35-+40 2 3.5m (110mm) 199
A28QA-9113 0-43 1.5 3 -
OH
B 152
A28QA-9115 1-60 2 1b 3m (115mm) - 168
A28QA-9117 20-40
1.5
3 - B 212
A28QJ-9100 0-95 1-5 1b 3m (100mm) OL F 173

See page 42 for Styles and Wiring Diagrams
Notes:
A = General purpose
B = Bulb stainless steel Stg = Stage, Bet = Between
C = Max. bulb temp. 85C
D = Concealed scale
E = Screwdriver adjustment
F = 3A switch
Sizes - 125 x 55 x 46.5mm (IP30 types), 125 x 60 x 59mm (IP65 types)
Switch Contact - SPDT
34
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
Temperature Sensors
TE-7000 Series
Room Command Modules
The TE-7000 Room Command Module is designed for
use with the VMA1400 series VAV Modular Assembly.
The module has an NTC temperature sensor, a dial for
setpoint adjustment within the range of 12-28C or -3
to +3K, and an occupancy button with an LED indicator.
If the VAV controller is not already in occupied mode, as
shown by the LED indicator, the occupant may press the
occupancy button to obtain comfort control for a set period
of time, normally defaulted to one hour.
The module also has a built-in connector for a PC with the software to test and
commission the VMA1400 series VAV Modular Assembly and the air supply system.
FEATURES
Power supply from VMA1400
Temperature sensor: NTC K2
Occupancy override button
Remote setpoint adjustment
Ordering
Codes Colour
Setpoint
Dial Range
List
Price
TE-7000-8002 Off-White / Gray Base
12-28C
102
TE-7000-8002-W White / White Base 102
TE-7000-8003 Off-White / Gray Base
-3 -+3 K
99
TE-7000-8003-W White / White Base 102
Note: Add -K to code for setpoint dial with serrated edge, e.g. TE-7000-8002-K,
TE-7000-8002-WK
Supply Voltage - Power from VMA1400
Size - 80 x 80 x 33mm
Protection Class - IP30
ACCESSORIES
Ordering Codes Description Price
TM-9100-8901 Dial-Stop screws kit (bag of 100 self-tapping screws) 20
TM-9100-8902 Serrated knob kit (bag of 10 knobs) - off-white 32
TM-9100-8902-W Serrated knob kit (bag of 10 knobs) - white 32
T22 and T25 Series
Stage Room Thermostats, Line Voltage
These thermostats with a sturdy steel cover are provided
with a liquid filled sensing element. This element is formed to
achieve maximum sensitivity to surrounding air temperature
changes. Coupled with a highly efficient diaphragm and
leverage mechanism, the element operates a totally enclosed
PENN switch contact with a close differential switching action
without the use of heat or cool anticipators.
FEATURES
Liquid filled elements
Dust tight PENN switch
Small differential
2-stage thermostats with dead band and automatic change over.
APPLICATION
These room thermostats are designed to control heating and/or cooling
equipment, in commercial industrial or residential installations. Typical uses are
for unit heaters, fan coils, cooling rooms etc. Type T22SRX can be used for either
heating or cooling. Type T25B (2 stages) can be used for: 2-stage heating, 2-stage
cooling, heating/cooling with dead band and automatic change over.
Ordering Codes
Range
(C)
Diff. (K)
Fixed Adjustment
Thermo-
meter Notes
List
Price
1-Stage Thermostats
T22SRX-9100
5-32 1
Knob

A
82
T22SRX-9101
-
83
T22SRX-9104 Concealed 83
2-Stage Thermostats
T25B-9101
1 1-3
Knob
-
- 145
T25B-9102 - B, C 152
T25B-9103 Knob D 212
(Continued next column)
Notes:
A = Automatic recycle
B = Concealed scale
C = Screwdriver adjustment
D = With 220Vac signal lamp to be wired separately
Power Supply - 230V, 50/60Hz
Switch - SPDT 3A, Open high
Protection Class - IP20
270XT Series
Freeze Protection Thermostats
Sensing element is 3 or 6 metres long to permit attaching
across the surface of a coil to guard against freezing at any
point. When any 30cm or more of this element senses a
temperature as low as the control setpoint, it will switch
off. A special version is available with bulb and 2m capillary,
range 24-+18C for clamp on or immersion purposes.
SPDT change over contacts permit the use of an alarm signal.
FEATURES
Dust tight PENN switch
270XTAN provided with trip-free manual reset
Controls have adjustable range
APPLICATION
These controls are designed for protection against freeze up of
hydronic heating coils, cooling coils and similar application.
Ordering
Codes
Range
(C)
Diff. (K)
Fixed

Style

Capillary Bulb
List
Price
Automatic Recycle
270XT-95008
-10-+12 3 9 -
3.2 x 6000mm 110
270XT-95078 3.2 x 3000mm 102
270XT-95068 -24-+18 4 1 2m 9.5 x 80mm 101
Trip-free Manual Reset
270XTAN-95008
-10-+12
-
9 -
3.2 x 6000mm 116
270XTAN-95088 3.2 x 3000mm 107
270XTAN-95048 -24-+18 1 (bulb) 2m 9.5 x 80mm 106
See page 42 for Style references
Power Supply - 230V, 50/60Hz
Switch Contact - SPDT 8A, open low
Size - 62 x 53 x 101mm (head)
Protection Class IP20
SENSORS / THERMOSTATS (cont)
General Accessories
for Temperature Controls
Ordering
Codes Description
Primary
Usage
List
Price
FTG13A-600R
Closed tank connector Style 1b elements,
Max. 10 bar, 120C, Min. -40C
A19/28/36 21
KIT012N600
Capillary brackets
(6 pieces)
270XT 13
35
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
RS-1100 Series
Room Command Modules
These Room Command Modules are designed for use
with Facility Explorer Series or System 91 controllers
from Johnson Controls and provides a 0-10V signal
directly proportional to the sensed temperature.
FEATURES
Remote temperature setpoint adjustment,
Occupancy override function, (models with or
without display)
Fan speed button
Ordering
Codes
Output
Signal
LCD
Display
Setpoint
Dial Range
Override
Function*
Fan Speed
Selection
List
Price
RS-1140-0000
0-10V
dc
-
- -
-
60
RS-1160-0000 12-28C
Pushbutton
86
RS-1160-0005 +/- 86
RS-1180-0000

12-28C
Integrated
114
RS-1180-0005 +/- 114
RS-1190-0000
-
12-28C
-
79
RS-1190-0005 +/- 79
RS-1180-0002

12-28C
Integrated

148
RS-1180-0007 +/- 148
Note: * Temporary occupancy override function
Supply Voltage - 5Vdc (all models) or 24Vac/dc (only models with display)
Temperature Output - 0-10Vdc
Size - 80 x 80 x 32mm (RS-1140 only), 80 x 80 x 35mm (other types)
Protection Class - IP30
ACCESSORIES
Ordering Codes Description Price
TM-1100-8931 Plastic surface mounting kit 14
TM-9100-8900 Special tool for opening enclosure 11
TM-2100 Series
Room Command Modules
This Series of Room Command Modules
is designed for use with the FCC and
Facility Explorer Series of DDC terminal unit
controllers. The setpoint dial enables the
room occupant to adjust the working set point
of the controller within the range of 12-28C
or -3-+3, according to the model number.
The occupancy button enables the occupant to switch
the mode of operation of the controller between COMFORT
and STANDBY or to request a temporary COMFORT mode during NIGHT operation.
An LED indicator shows the current operating mode. A Room Command Module with
a 3-speed fan override adjuster is available.
FEATURES
Passive sensor
Remote temperature setpoint adjustment
3-speed fan override
Occupancy override button
Ordering
Codes
Sensing
Element
Setpoint
Dial Scale
Fan Speed
Override
Occupancy
Override
List
Price
TM-2140-0000
NTC 10K
-
-
- 43
TM-2150-0000

47
TM-2160-0000 12-28C 60
TM-2160-0005 +/- 50
TM-2160-0002 12-28C
3-Speed
59
TM-2160-0007 +/- 59
TM-2190-0000 12-28C
- -
50
TM-2190-0005 +/- 50
ACCESSORIES
Ordering Codes Description Price
TM-1100-8931 Plastic base for surface mount 14
TE-9100-8501 Unit Mount NTC K2 Temperature Sensor (1.5 m cable) 26
TM-9100-8900 Special Tool for opening enclosure 11
Supply Voltage - Power from FCC and Facility Explorer Series
Size - 80 x 80 x 32mm (TM-2140 only), 80 x 80 x 35mm (other types)
Protection Class - IP30
Ordering
Codes
Sensing
Element
Setpoint
Dial Scale
Fan Speed
Override
Occupancy
Override
List
Price
TM-1140-0000
NTC K2
-
-
- 43
TM-1150-0000

56
TM-1160-0000 12-28C 60
TM-1160-0005 +/- 60
TM-1160-0002 12-28C
3-Speed
71
TM-1160-0007
+/-
71
TM-1170-0005
Without
- 56
TM-1170-0007 3-Speed 64
TM-1190-0000
NTC K2
12-28C
- -
60
TM-1190-0005 +/- 60
Supply Voltage - Power from TC-9102, TC-9109 and TCU Series
Unit Size - 80 x 80 x 32mm (TM-1140 only), 80 x 80 x 35mm (other types)
Protection Class - IP30
ACCESSORIES
Ordering Codes Description Price
TM-1100-8931 Plastic Base for surface mount 14
TE-9100-8501 Unit Mount NTC K2 Temperature Sensor (1.5m cable) 26
TM-9100-8900 Special Tool for opening enclosure 11
TM-1100 Series
Room Command Modules
The TM-1100 Series of Room Command
Modules are designed for use with the
TC-9102, TC-9109 and TCU series of DDC
terminal unit controllers. The setpoint dial
enables the room occupant to adjust the
working set point of the controller within the
range of 12-28C or -3-+3, according to the
model number.
The occupancy button enables the occupant to switch the mode of operation of the
controller between COMFORT and STANDBY or to request a temporary COMFORT
mode during NIGHT operation.
An LED indicator shows the current operating mode. For TC-9102 and TCU Fan Coil
Unit controllers, a Room Command Module with a 3-speed fan override is available.
Models without a temperature sensing element are provided for application where the
temperature sensor is mounted inside the Fan Coil Unit.
FEATURES
Passive Sensor
Remote Temperature Setpoint adjustment
3-speed fan override
Occupancy override button
(Continued next column)
36
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
TS-9100, TE-9100 Series
Plant Sensors
The TS-9100/TE-9100 Series
Temperature Sensors and
Transducers provide a passive
or active signal that corresponds with
the air or water temperature
in heating, ventilating and
air-conditioning applications.
They provide either a 0-10Vdc signal
directly proportional to the sensed
temperature, or a passive resistive
NTC, Pt1000 or Pt100 signal.
FEATURES
Wide range of enclosures and signal outputs
For immersion applications, well can be mounted before rod sensor is mounted
Various lengths of tubes and wells for duct and immersion applications
IP54 enclosure
Ordering
Codes
Output
Signal
Sensor
Type
Rod Length
(mm)
Temp.
Range (C)
List
Price
TS-9101-8101
0-10V
Remote
element
-
40-+50 44
TS-9101-8103 0-40 55
TS-9101-8104 0-100 44
TS-9101-8212
Rod*
160
-20-+40 60
TS-9101-8213 0-40 60
TS-9101-8214 0-100 60
TS-9101-8222
200
-20-+40 84
TS-9101-8223 0-40 84
TS-9101-8224 0-100 84
TS-9101-8225 0-150 84
TS-9101-8226 20-120 67
TS-9101-8227 50-150 83
TS-9101-8232
300
-20-+40 87
TS-9101-8233 0-40 70
TS-9101-8234 0-100 70
TS-9101-8235 0-150 87
TS-9101-8252
500
-20-+40 84
TS-9101-8253 0-40 84
TS-9101-8254 0-100 105
TS-9101-8322
Rod Fast
Response
200
-20-+40 105
TS-9101-8323 0-40 105
TS-9101-8324 0-100 84
TS-9101-8333 300
0-40
107
TS-9101-8353 500 130
TS-9101-8401
Outdoor
-
40-+50 57
TS-9101-8402
20-+40
57
TS-9101-8602
Strap-on
72
TS-9101-8604 0-100 69
TS-9101-8703 Ceiling 0-40 56
Note: * Rod sensor can either be for: - Duct applications (alone)
- Immersions applications (with well)
(Continued next column)
Ordering
Codes
Output
Signal
Sensor
Type
Rod Length
(mm)
Temp
Range (C)
List
Price
TE-9100-8501
NTC K2
Cable Sensor -20-+40 25
TS-9103-8220
Rod*
200
0-40
105
TS-9103-8250 500 92
TS-9103-8320
Rod fast
response
200 105
TS-9103-8400 Outdoor
-
84
TS-9103-8600 Strap-on 57
TS-9103-8700 Ceiling 69
TE-9100-8502
NTC K10
Cable Sensor -20-+40 29
TS-9104-8220
Rod*
200
0-120
53
TS-9104-8230 300 50
TS-9104-8320
Rod fast
response
200 117
TS-9104-8600 Strap-on - 49
TS-9105-8220
Pt100
Rod*
200
-20-+150
76
TS-9105-8230 300 72
TS-9105-8250 500 71
TS-9105-8400 Outdoor
-
-40-+50 46
TS-9105-8600 Strap-on -20-+100 87
TS-9105-8700 Ceiling 0-40 71
TS-9106-8210
Pt1000
Rod*
160
-20-+150
68
TS-9106-8220 200 65
TS-9106-8230 300 72
TS-9106-8310
Rod fast
response
160 70
TS-9106-8320 200 68
TS-9106-8330 300 73
TS-9106-8400 Outdoor
-
-40-+50 52
TS-9106-8600 Strap-on -20-+100 73
Note: * Rod sensor can either be for: - Duct applications (alone)
- Immersions applications (with well)
ACCESSORY
Ordering Codes Description Price
TS-9100-8950 Duct Mounting Flange 11
IMMERSION WELLS
Ordering
Codes Material Thread
Length
(mm)
External
Diameter (mm)
List
Price
TS-9100-8905
Copper R 1/2
50 9 26
TS-9100-8901 120
12
27
TS-9100-8907 150 12
TS-9100-8902 200 28
TS-9100-8903 260 23
TS-9100-8921
Stainless
steel
R 1/2
120
12
69
TS-9100-8927 150 71
TS-9100-8922 200 76
TS-9100-8923 260 77
TS-9100-8915
G 1/2
50 9 52
TS-9100-8911 120
12
69
TS-9100-8917 150 49
TS-9100-8912 200 74
TS-9100-8913 260 50
SENSORS / THERMOSTATS (cont)
37
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
EP-1000 Series
Electro-Pneumatic Transducers
The EP-1110 is an electric to air Pressure Transducer.
The unit is designed to convert an electrical input signal
into a pressure output with a linear relationship.
These service and data information sheets (in brief SDI) are
operating instructions for the safe installation and operation of the
EP-1110-700x (EP-1110) electro-pneumatic transformer. Should
difficulties occur during installation which, cannot be solved with
the help of this SDI please ask the Sales Support Team.
Ordering
Codes Input * Output **
List
Price
EP-1110-7001
0-10Vdc,
Ri 1 k
20-100 kPa 467
EP-1110-7002
2-10Vdc,
0-10Vdc, Ri 1 k
20-100 kPa,
3-100 kPa
704
EP-1110-7003
0-20 mAdc,
Ri 450
20-100 kPa 679
EP-1110-7004
4-20Vdc,
0-20 mA(dc) Ri 450
20-100 kPa,
3-100 kPa
704
* Current through coil approx. 10 mA
** Linearly proportional to input
Size - 188 x 62 x 74.5mm
Electro-Pneumatic Transducers
EP-2000 Series
Electro-Pneumatic Transducers
The EP-2000 Electro-Pneumatic Transducer with motor drive, is
used for converting an electrical contact signal into a 0.2-1 bar
pneumatic standard signal.
These service and data information sheets (in brief SDI) are
operating instructions for the safe installation and operation of
the EP-2000-70xx (EP-2000) Electro-Pneumatic transducer.
Should difficulties occur during installation which, cannot
be solved with the help of this SDI please ask the Sales
Support Team.
FEATURES
High linearity and low hysteresis
High accuracy
Small supply air influence and air consumption
Ordering
Codes
Limit Switch
& Potentiometer ** Accessories
Voltage
Supply
List
Price
EP-2000-7001
120 sec.
-
230V 815
EP-2000-7004 24V 607
EP-2000-7021
2 k pot.
230V 870
EP-2000-7024 24V 865
* Option upon request
** 2 k Feedback potentiometer
Supply Voltage 230V, 50/60Hz, +6/10% or 24V, 50Hz, 10%
Size - 198 x 62 x 75mm
EP-8000 Series
Electro-Pneumatic Transducers
These transducers convert a voltage or current
signal from an electronic controller into a pneumatic
output pressure signal. An increase or decrease in
the input signal proportionally increases or decreases
(respectively) the output pressure signal from the
EP-8000.
Sequencing of pneumatic valve or damper actuators
can be accomplished using a V-9502 (Valve) or D-9502
(Damper) Actuator Positioner.
FEATURES
Compact, simple design
Hypodermic needle test point
Factory set, fully adjustable zero and span
High accuracy with low hysteresis
Ordering
Codes Input Range Output
Factory
Output
List
Price
EP-8000-1 0.5-9Vdc Low Volume (non-relay)
7-126 kPa
(1-18 psig)
143
EP-8000-2 0.25-9.5Vdc High Volume (relay)
3.5-133 kPa
(0.5-19 psig)
134
EP-8000-3
4-20 mAdc
Low Volume (non-relay)
21-105 kPa
(3-15 psig)
143
EP-8000-4 High Volume (relay) 134
ACCESSORIES
Ordering Codes Description Price
R-3710-8205 0.18mm Restrictor (required for low volume models) 15
EP-8000-101 Electro-Pneumatic Transducer Mounting Kit 18
A-4000-8001 Inline Air Filter (required for all models) 28
JC 5361 Hypodermic Needle Test Probe Assembly 36
G-2010 Series 0-210 kPa (0-30 psig) Gauge POA
Connections - Barbed air connections for 5/32 or 1/4 inch o.d. polytubing.
ELECTRO-PNEUMATIC TRANSDUCERS
38
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
PARAMETER DESCRIPTIONS
Display
Codes
Parameters
(Setting Range)
D
e
f
a
u
l
t
M
S
1

M
S

x
1
M
S
2
M
S
4
Temperature Control Parameters
H1 Hysteresis - HY (1-9 K) 2

S2
Setpoint 2 (direct/reverse = 1-40 units,
deadband = 2-40 units, indip. setpoint = low to
high limit)
3 -

H2 Hysteresis - HY (1-9 K) -40 -

S3 Setpoint 3 (1-40 units) -40 - -

H3 Hysteresis - HY (1-9 K) -40 - -

S4 Setpoint 4 (1-40 units) -40 - -

H4 Hysteresis - HY (1-9 K) -40 - -

LL Lower setpoint limit - LL (-40C to higher limit) -40



HL Higher setpoint limit - HL (lower limit to 125 units) 70

CC Anti short cycling cooling - CC (0-9 min) 2

CH Anti short cycling heating - CH (0-99 min) 60

rt Soft start (0-99 min / units) 3

Alarm Parameters
AH
High temperature alarm
(0-50 units related to setpoint)
10

AL
Low temperature alarm
(-50-0 units related to setpoint)
-10

Ad Alarm differential (1-9 units) 1

At Alarm time delay (0-99 min) 30

Temperature Parameters
Lc Non compensated band (0-20 K) OF - -

Uc Heating compensation (0-6 K/K) 0 - -

nc Cooling compensation (0-6 K/K) 20 - -

Other Parameters
So Sensor offset (-20-+20 units) 0

Un
Temperature units (0 = Celsius degrees,
1 = Fahrenheit degrees)
0

PU Display updating time delay (1-99 sec) 7

iF
Digital input function (0 = not used, 1 = shut off
and alarm signalling, 2 = stand by mode,
3 = remote switch off)
6 -

Sb Stand-by bias (0-20 units) 40 -

Id Digital input time delay (0-99 sec) 5 -

IS Interstage delay (3-99 sec) 20 -

Lr Low range analogue input 1 (-40 to high range) 20

-
Hr High range analogue input 1 (low range to 100) 20

-
Note:
When there are two setpoints (MS2 or MS4 is configured for independent setpoint
mode), the low alarm is linked to the lowest setpoint and the high alarm is linked to
the highest setpoint.
MS Series
General Purpose and Multi Stages
This range of versatile controls is
intended for single or multistage (2 or
4 stages) applications such as heating,
cooling but also humidity or pressure
depending on the input type. This range
incorporates all control functions as required
by modern applications and it exists in both
panel mount and DIN rail enclosures.
FEATURES
Up to four relays in panel mount enclosure
Accept temperature (A99) and 0-10V sensor signal depending on models
Accurate and interchangeable IP68 sensor
Wide range of enclosures for sensors available
Keyboard lock
Ordering
Codes
Range
(C)
Power
Supply Enclosure Input
Output
Rating
List
Price
MS Display
DIS12T-1C
-40-
+70
12Vac/dc
Panel
A99 *
Sensor
-
87
DIS230T-1C 230Vac 87
DIS12V-1C
0-100%
(Rh)
12Vac
0-10V
**
-
87
DIS230V-1C 230Vac 87
1-stage Control (Alarm Output - Open Collector 40Vdc/100 mA)
MS1PM12RT-1C
-40-
+70
12Vac/dc
Panel
A99 *
Sensor
SPST 100
MS1PM230T-1C
230Vac
SPDT 155
MS1DR230T-1C DIN-rail SPST 118
MS1PM12RV-1C
-40-
+100
12Vac
Panel
0-10V
**
SPST 99
MS1PM230V-1C
230Vac
SPDT 102
MS1DR230V-1C DIN-rail SPST 117
2-stage Control
MS2PM12RT-1C
-40-
+70
12Vac/dc Panel
A99 *
Sensor
SPST
146
MS2DR230T-1C 230Vac
DIN-rail
155
MS2DR48DT-1C
12-24Vac/dc
48Vdc
SPDT 192
MS2PM12RV-1C
-40-
+100
12Vac Panel
0-10V
**
SPST
146
MS2DR230V-1C 230Vac DIN-rail 149
4-stage Control
MS4PM12RT-1C
-40-
+70
12Vac/dc Panel
A99 *
Sensor
SPST
172
MS4DR230T-1C 230Vac DIN-rail 195
MS4DR48T-1C
12-24Vac/dc
48Vdc
Panel SPDT 195
Notes:
* A99 sensor (included)
** 0-10V from humidity sensor (not included)
Output Rating - 250Vac, 8(3)A (each stage)
Sizes - 118 x 70 x 63mm (DIN-rail types), 35 x 75 x 68mm (panel types)
Protection Class - Panel (overall IP20, front IP54), DIN rail (IP20)
Controllers - Field Controls
REFRIGERATION CONTROLLERS
39
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
CR Series
Electrical Cabinets
Designed to facilitate installers work, this range
of electrical cabinets is intended for use in
cold rooms working at positive or negative
temperatures and powered either with single
phase or three phase power supply. Based on
specifically designed controllers, it incorporates
all control functions as required by modern
cold room units, such as compressor control,
defrost management, fan management, alarm function and solenoid valve for pump
down. It also includes all the safety equipment needed such as circuit breakers for
the compressor and for the controller. Particular attention has been given to the
accessibility so that the installation time will be reduced to a minimum. Space has
been left available for customisation.
FEATURES
Power rating from: 0.37-1.5 kW in single phase 1.5-7.5 kW in three phases
Most wiring integrated on the controller
Specifically designed controller to manage Pump Down
Accurate and interchangeable
IP68 sensor
IP65 standard DIN polycarbonate cabinets
Integrate circuit breaker for motor and controller
In field extension
Main switch
POSITIVE TEMPERATURE COLD ROOM CABINETS
Ordering
Codes
Power Supply Compressor
Eva. Fan
(Amps)
List
Price
Vac () Power AC-3 (Amps)
12 Module Cabinets
CR-PS037-1
230 (1)
0.37 kW (5)
1.6
198
CR-PS075-1 0.75 kW (8) 208
CR-PS110-1 1.1 kW (10) 3.2 228
CR-PS150-1 1.5 kW (12) 4.8 244
18 Module Cabinets
CR-PT150-1
400 (3)
1.5 kW (3.5)
3.2
301
CR-PT250-1 2.5 kW (5.7) 303
CR-PT400-1 4.0 kW (8.5)
4.8
307
CR-PT550-1 5.5 kW (11.5) 314
CR-PT750-1 7.5 kW (15.5) 321
NEGATIVE TEMPERATURE COLD ROOM CABINETS
Ordering
Codes
Power Supply Compressor
Eva. Fan
(Amps)
Defrost
(Amps)
List
Price
Vac Power AC-3 (Amps)
12 Module Cabinets
CR-NS037-1
230 (1)
0.37 kW (5)
1.6
8 227
CR-NS075-1 0.75 kW (8)
12
254
CR-NS110-1 1.1 kW (10) 3.2 260
CR-NS150-1 1.5 kW (12) 4.8 16 267
18 Module Cabinets with Auxiliary Output*
CR-NT150-1
400 (3)
1.5 kW (3.5)
3.2 12
322
CR-NT250-1 2.5 kW (5.7) 327
CR-NT400-1 4.0 kW (8.5)
4.8 15
334
CR-NT550-1 5.5 kW (11.5) 341
CR-NT750-1 7.5 kW (15.5) 374
24 Module Cabinets with 3-Phase Defrost
CR-NDT150-1
400 (3)
1.5 kW (3.5)
3.2
3 x 5 450
CR-NDT250-1 2.5 kW (5.7) 3 x 9 477
CR-NDT400-1 4.0 kW (8.5)
4.8
3 x 10 485
CR-NDT550-1 5.5 kW (11.5) 3 x 12 501
CR-NDT750-1 7.5 kW (15.5) 3 x 16 508
36 Module Cabinets with Auxillary Output*, 3-Phase Defrost and Fan
CR-NFDT150-1
400 (3)
1.5 kW (3.5)
3 x 2
3 x 5 425
CR-NFDT400-1 4.0 kW (8.5) 3 x 10 487
CR-NFDT750-1 7.5 kW (15.5) 3 x 16 589
Note: * Condenser fan or door frame heater. Auxillary output 3 Amps
PARAMETER DESCRIPTIONS
Display
Codes
Parameters
(Setting Range)
D
e
f
a
u
l
t
M
R
1
2
D
R
M
R
1
5
D
R
Temperature Control Parameters
Hy Hysteresis - HY (1-9 K) 2

LL Lower setpoint limit - LL (-40C to higher limit) -40

HL Higher setpoint limit - HL (lower limit to 70C) 70

CC Anti short cycling - CC (0-9 min) 2

Co Deep freezing time - Co (0-99 min) 60

Alarm Parameters
AH
High temperature alarm (0-50C related to
setpoint)
10

AL
Low temperature alarm (-50-0C related to
setpoint)
-10

Ad Alarm differential (1-9 K) 1

At Alarm time delay (0-99 min) 30

Defrost Parameters
dF
Defrost function. (0 = electric heater,
1 = hot gas)
0 -

dE
Defrost end function. (0 = by time,
1 = by temperature)
1 -

dt Defrost termination temp. (0-20C) 7 -

di Defrost interval time (0-99 hours) 12



dd Max. defrost duration (0-99 min) 40

dC Dripping time (0-99 min) 5

dU First defrost after power ON (OFF 0-99 min) OFF

dP
Display during defrost. (0 = last value before
defrost, 1 = setpoint)
0

dr Delay displayed temp. after defrost (1-99 min) 20

Digital Input Parameters
iF
Digital input function (0 = instrument off,
1 = alarm signalling, 2 = alarm reset, 3 = alarm
reset and fan cut-off)
0

id Digital input time delay (0-99 sec) 5

Fan Control Parameters
FF
Fan operating function (0 = parallel with
compressor, 1 = continuous running)
0 -

Fd
Fan start-up delay after defrost end and
power up (0-99 min.)
5 -

Fr
Fan start-up temperature after defrost end and
power up (-30-+5C/-22-+41 F)
2 -

Other Parameters
SF
Thermostat operating function when sensor
failure (0 = always ON, 1 = always OFF,
2 = automatic)
2

So Offset thermostat sensor (-20-+20 units) 0

Un Temperature units (0 =C, 1 = F) 0

PU Display updating time delay (1-99 sec) 1

24 Moduler Type
18 Moduler Type
12 Moduler Type
36 Moduler Type
Sizes:
220 x 275 x 140mm (12 Module types)
220 x 380 x 140mm (18 Module types)
370 x 275 x 140mm (24 Module types)
370 x 380 x 140mm (36 Module types)
40
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
P215PR Series
Direct Mount Pressure Actuated, Single-phase
These direct mount pressure actuated condenser fan
speed controllers are designed for speed variation of
single-phase motors.
Head pressure control of a refrigeration system, through
speed variation of the fan on an air-cooled condenser, results
in optimum performance throughout the year. A pressure
actuated device, gives the most direct and fastest response to
pressure variations in the refrigerant system.
The controller varies the supply voltage to the motor from
30% to at least 95% over the proportional band using the
phase cutting principle. This provides speed variation of
permanent split capacitor or shaded pole motors that do not
draw more than 4A (rms) full load current. Cut-off models (fan stops at low pressure)
as well as minimum speed models (fan keeps running at 30%) are available. The
controllers can be used in non-corrosive refrigerant systems.
FEATURES
Condenser pressure control by fan speed variation
Direct mount
Setpoint screw on top
Built-in suppression filter
Quick connector plug included
Ordering
Codes
Range
(bar)

Style
Setpoint
(bar)
P.B.
(bar) Notes
List
Price
P215PR-9200 10-25
47
19 4.5
-
99
P215PR-9202 22-42 26 5.5 99
P215PR-9800
10-25
28
19 4.5
111
P215PR-9230
47
A
109
P215PR-9232 22-42 26 5.5 109
P215PR-9250 10-25 19 4.5 A, B 118
Notes: Refer to page 42 for Style references
A = Bulk Pack
B = Bulk Pack, 2 metre cable connector included
Supply Voltage - 230Vac, 50/60Hz
Rating - 4 Amp
Controller Mode - Cut-off
Size - 106 x 65mm (Style 47 types), head and stem 90mm (Style 28 type)
Protection Class - IP65
Controllers - Fan Speed
P215DP/SH/ST Series
Pressure Actuated, Single-phase
These controllers are designed for speed variation of single
phase motors, especially for fan speed control on air
cooled condensers.
Head pressure control of a refrigeration system, through
speed variation of the fan on an air-cooled condenser,
results in optimum performance throughout the year.
Using a pressure transducer as the input device to the fan
speed controller, gives the most direct and fastest response to
pressure variations in the refrigerant system. The controller varies
the supply voltage to the motor from 45% to at least 95% over the proportional band
using the phase cutting principle. It is recommended to confirm with the electric
motor manufacturer if a controller using the phase cutting principle for speed variation
can be used. The controller used for dual pressure input varies the fan speed by
directly sensing the pressure changes of two separate refrigerant circuits.
The setpoint of each pressure transducer can be separately adjusted. The controller
selects the input with the greatest cooling demand to control the fan speed. The
transducers can be used in non-corrosive refrigerant systems.
FEATURES
Condenser pressure control by fan speed variation
Transducers with proven reliability
Easy accessible setpoint screw
Adjustable minimum speed or cut-off selection
Dual input possibility (P215DP only, by adding another P35 transducer)
Heatpump input available (P215SH)
Ordering
Codes
Range
(bar)
P.B.
(bar)
Setpoint
(bar)
Pressure
Connection Notes
List
Price
8 Amp Rating
P215DP-9100 14-24 4 16
90cm capillary
(style 50)
A
257
P215DP-9101 8-14 2.5 10 302
P215DP-9600 14-24 4 16
90cm capillary
(style 51)
319
P215DP-9601 8-14 2.5 10 319
P215DP-9800 14-24 4 16 Braze con. (st. 28) 392
P215DP-9102 22-42 6 30 90cm cap. (st. 50) B 318
4 Amp Rating
P215SH-9100 14-24 4 16
90cm capillary
(style 50)
C
126
P215SH-9101 8-14 2.5 10 165
P215SH-9102 22-42 6 30 B 151
P215SH-9800 14-24 4 16 Braze con. (st. 28) C 199
6 Amp Rating
P215ST-9100 14-24 4 16
90cm capillary
(style 50)
C
164
P215ST-9101 8-14 2.5 10 164
P215ST-9600 14-24 4 16 90cm cap. (st. 51) 219
P215ST-9102 22-42 6 30 90cm cap. (st. 50) B 228
Notes:
See page 42 for Style references
A = Single/dual input. For dual input a second separate transducer has to be ordered!
B = For use on R410A applications
C = Single input
Supply Voltage - 230Vac, 50/60Hz
Size - 205 x 213 x 107mm
Rating - 4, 6, 8 Amp
Protection Class - IP54
REFRIGERATION CONTROLLERS (cont)
41
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
P255 Series
Single/Dual Input Pressure Actuated (for 3-phase Motors)
These controllers are designed for speed variation of 3-phase motors, especially for
fan speed control on air cooled condensers.
Head pressure control of a refrigeration system, through
speed variation of the fan, results in optimum
performance throughout the year.
Using a pressure transducer as the input device, gives
the most direct and fastest response to pressure
variations in the refrigerant system. The controller
varies the supply voltage to the motor from 30% to
at least 96% over the proportional band using the
phase cutting principle. It is recommended to confirm
with the electric motor manufacturer if a controller
using the phase cutting principle for speed variation can
be used. Motors that will be controlled by the P255 should
not draw more than 5A per phase.
The controller used for dual pressure input varies the fan speed by directly sensing the
pressure changes of two separate refrigerant circuits. Each pressure transducer can be
adjusted at a setpoint between 8 to 42 bar. The controller selects the input with the
greatest cooling demand. The transducers can be used in non-corrosive
refrigerant systems.
FEATURES
Condenser pressure control by fan speed variation
Dual input possibility
Transducers with proven reliability
Easy accessible setpoint screw
Minimum speed or cut-off selection
Adjustable minimum speed or cut-off
Adjustable maximum speed limit
Proportional band adjustment
Contact input to force output to max. or off
Allows connection in both Star and Delta configurations
Motor speed action can be reversed by interchanging only two wires
Adjustable hysteresis in cut-off mode
Cos motor adjustment
Ordering
Codes
Range
(bar)
P.B
(bar)

Style
Full Volt.
Setpoint Notes
List
Price
230V, 3-phase
P255ML-9200 14-24 1-6 47 16 A 630
400V, 3-phase
P255MM-9100
14-24 1-6
45A
16
- 668
P255MM-9200
47 A
640
P255MM-9201 8-14 0.5-4 10 855
P255MM-9600
14-24 1-6
13
16
- 618
P255MM-9500
50
B 640
P255MM-9501 8-14 0.5-4 10 C 640
P255MM-9503 22-42 1-8 30 D 890
See page 42 for Style references
For a 4 Amp rating and UL approval please contact the Sales Support Team.
Notes:
A = Direct mount sensor
B = Same as P255MM-9100 but Style 50
C = Same as P255MM-9101 but Style 50
D = For use on R410A applications
Supply Voltage - 230Vac or 400V, 50/60Hz, 3 Phase
Rating - 5 Amp
Controller Mode - Cut-off
Size - 205 x 213 x 107mm
Protection Class - IP54 (for electronic module)
P215LR/BR/TR Series
Single/Dual/Triple Input Pressure Actuated
The P215LR is a single pressure input, the P215BR is a dual
pressure input and the P215TR is a triple pressure input fan
speed controller for air cooled condensers with respectively
single, dual and triple refrigerant circuits.
The controller varies the fan speed by directly sensing the
pressure changes of one, two or three separate refrigerant
circuits. The setpoint of each pressure transducer can be
separately adjusted. The controller selects the input with the
greatest cooling demand to control the fan speed.
The controllers can be used in non corrosive refrigerant systems
and vary the supply voltage to the motor from 45% to 95% of the supplied voltage
using the phase cutting principle. It is recommended to confirm with the electric motor
manufacturer if a controller using the phase cutting principle for speed variation can
be used. If the pressure drops below the adjusted set-point minus the proportional
band, the output to the motor is zero volt or the adjusted min. speed setting.
FEATURES
Condenser pressure control by fan speed variation
Model with heat pump input available
Transducers with proven reliability
Easy accessible set-point screw
Adjustable minimum speed or cut-off selection (only on LR and BR models)
Dual pressure input (BR models)
Triple pressure input (TR models)
Ordering
Codes
Range
(bar)
P.B
(bar)
Setpoint
(bar)
Pressure
Conn. (Style) Notes
List
Price
3 Amp Rating
P215LR-9110 14-24 4 16
90cm cap.
(style 50)
A, B
154
P215LR-9111 8-14 2.5 10 111
P215LR-9130 Bulk pack version of type P215LR-9110 (15 pcs) 1755
P215LR-9210
14-24 4 16
Direct mount (47) 117
P215LR-9610
Direct mount
(style 51)
135
P215LR-9611 8-14 2.5 10 135
P215LR-9114 22-42 6 30
90cm cap.
(style 50)
C 136
P215LR-9140
14-24 4 16
D 146
P215LR-9120 E 221
P215BR-9110
A, F
243
P215BR-9111 8-14 2.5 10 257
P215BR-9210
14-24 4 16
Direct mount (47) 137
P215TR-9110 90cm cap. (50) G 284
See page 42 for Style references
Notes:
A = Minimum speed adjustable.
B = Single pressure input
C = For R410A applications
D = 230V heat pump input
REPLACEMENT PARTS (for Fan Speed Control 230V Versions)
Controller
Code
Range
(bar)
Element
Style
Replacement Item
Pressure Transducer Electronic Module
P215LR-9110 14-24 50 P35AC-9500 P38AA-9111
P215LR-9111 8-14 50 P35AC-9501 P38AA-9111
P215LR-9210 14-24 47 P35AC-9502 P38AA-9111
P215LR-9211 8-14 47 P35AC-9503 P38AA-9111
P215LR-9610 14-24 51 P35AC-9507 P38AA-9111
P215LR-9611 8-14 51 P35AC-9508 P38AA-9111
P215BR-9110 14-24 50 P35AC-9500 P38AA-9211
P215BR-9111 8-14 50 P35AC-9501 P38AA-9211
P215BR-9210 14-24 47 P35AC-9202 P38AA-9211
P215BR-9211 8-14 47 P35AC-9203 P38AA-9211
Notes: See page 42 for Style references
P35 Mechanical Transducers see page 30
P38 Electronic Boards please refer to the Sales Support Team
E = 400V version
F = Dual pressure input
G = Triple pressure input
Supply Voltage - 230V, 50/60Hz
Rating - 3 Amp
Size - 118 x 70 x 53mm
42
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
Style Reference & Wiring Diagrams
Style 1a Style 1b Style 2 Style 3
Style 4H Style 5 Style 13 Style 15
Style 28 Style 29A Style 30 Style 34
Style 35 Style 45A Style 47 Style 50
Style 51
M
max. 20A
Line~
A
C
B
A - C opens on pressure decrease
max. 20A
Line~
A
C
B
A - B opens on pressure increase
M
M
max. 20A
Line~
A
B
C
A - C opens on pressure increase
Wiring 1 Wiring 2 Wiring 3
Wiring 4 Wiring 5
A - C opens on pressure increase
A - B closes simultaneously
A - C opens on pressure increase
A - D closes simultaneously
Left side HP.
Right side HP.
max. 20A
Line~
M
HP HP
A
B
D
C
max. 20A
Line~
M
A
HP LP
A - C opens on pressure decrease
A - B closes simultaneously
A - C opens on pressure increase
A - D closes simultaneously
LP.
HP.
D
C
B
Wiring 6
max. 20A
Line~
M1
HP HP
A
B
M2
D
43
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
Selection Reference Tables
VG1201, VG1801 Series
DN15-50, Threaded Valves
PROPORTIONAL ACTUATORS (Factory-mounted valve/actuator assemblies)
Spring Return -

Supply Voltage 24Vac 24Vac


Torque 4 Nm 8 Nm 6 Nm 16 Nm
Close-off Pressure 1380 kPa 1380 kPa
Aux. Switches - 2 x SPDT - 1 x SPDT - 2 x SPDT
Actuator Codes VA9104-GGA-5S VA9104-GGA-1S M9108-GGA-5 M9108-GGC-5 M9206-GGA-5S M9206-GGB-5S M9216-HGA-1 M9216-HGC-1
Linkage Codes - M9000-525-5 M9000-520-5 M9000-510-5
Ordering Code
Suffix for Assemblies
+5T4GGA +5A4GGA +5A8GGA +5A8GGC
+536GGA (SO)
+556GGA (SC)
+536GGB (SO)
+556GGB (SC)
+526HGA (SO)
+546HGA (SC)
+526HGC (SO)
+546HGC (SC)
Valve Body Size Valid combinations of valves, linkages and actuators
DN15

- -
DN20

- -
DN25

- -
DN32 - -

- -
DN40 - -

- -
DN50 - -

- -

Note: FA-2000 / 3000 heavy duty actuators are available on request if a higher close-off is required. (SO) = Spring opens, (SC) = Spring closes
FLOATING OR ON/OFF ACTUATORS (Factory-mounted valve/actuator assemblies)
Spring Return -

Supply Voltage 24Vac * 24Vac ** 230Vac ** 24Vac *


Torque 4 Nm 8 Nm 6 Nm 16 Nm
Close-off Pressure 1380 kPa 1380 kPa
Aux. Switches - 2 x SPDT - 2 x SPDT - 1 x SPDT - 2 x SPDT
Actuator Codes
VA9104-
AGA-5S
VA9104-
AGA-1S
VA9104-
IGA-5S
VA9104-
IGA-1S
M9108-
AGA-5
M9108-
AGC-5
M9108-
ADA-5
M9108-
ADC-5
M9206-AGA-5S M9206-AGB-5S M9216-AGA-1 M9216-AGC-1
Linkage Codes - M9000-525-5 M9000-520-5 M9000-510-5
Ordering Code
Suffix for Assemblies
+5T4
AGA
+5A4
AGA
+5T4
IGA
+5A4
IGA
+5A8
AGA
+5A8
AGC
+5A8
ADA
+5A8
ADC
+536AGA (SO)
+556AGA (SC)
+536AGB (SO)
+556AGB (SC)
+526AGA (SO)
+546AGA (SC)
+526AGC (SO)
+546AGC (SC)
Valve Body Size Valid combinations of valves, linkages and actuators
DN15

- -
DN20

- -
DN25

- -
DN32 - - - -

- -
DN40 - - - -

- -
DN50 - - - -

- -

Notes: FA-2000 / 3000 heavy duty actuators are available on request if a higher close-off is required. (SO) = Spring opens, (SC) = Spring closes
* Floating control signal ** Floating with time-out and On/Off control signal
ON/OFF ACTUATORS (Factory-mounted valve/actuator assemblies)
Spring Return

Supply Voltage 24Vac 230Vac


Torque 6 Nm 16 Nm 6 Nm 16 Nm
Close-off Pressure 1380 kPa 1380 kPa
Aux. Switches - 1 x SPDT - 2 x SPDT - 1 x SPDT - 2 x SPDT
Actuator Codes M9206-BGA-5S M9206-BGB-5S M9216-BGA-1 M9216-BGC-1 M9206-BDA-5S M9206-BDB-5S M9216-BDA-1 M9216-BDC-1
Linkage Codes M9000-520-5 M9000-510-5 M9000-520-5 M9000-510-5
Ordering Code
Suffix for Assemblies
+536BGA (SO)
+556BGA (SC)
+536BGB (SO)
+556BGB (SC)
+526BGA (SO)
+546BGA (SC)
+526BGC (SO)
+546BGC (SC)
+536BDA (SO)
+556BDA (SC)
+536BDB (SO)
+556BDB (SC)
+526BDA (SO)
+546BDA (SC)
+526BDC (SO)
+546BDC (SC)
Valve Body Size Valid combinations of valves, linkages and actuators
DN15

- -

- -
DN20

- -

- -
DN25

- -

- -
DN32

- -

- -
DN40

- -

- -
DN50 - -

- -

Note: FA-2000 / 3000 heavy duty actuators are available on request if a higher close-off is required. (SO) = Spring opens, (SC) = Spring closes
44
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
Selection Reference Tables (cont)
VG7000 Series
DN15-50, PN16 Threaded Valves
BRASS TRIM VALVES - 2-way & 3-way Mixing Configurations
Actuator Codes VA-731x* VA-77xx VA-78xx
Torque 150N 500N 1000N
Valve Body Size Kvs Close-off Pressure (kPa)
DN15 0.25 / 0.4 1600
1600
-
0.63 / 1.0 / 1.6 700
2.5 / 4.0 400 1490
DN20 6.3 250 950
DN25 10
-
595 1235
DN32 16 360 750
DN40 25 235 480
DN50 40 145 310
Notes: FA-2000 / 3000 heavy duty actuators are available on request if a higher close-off is required.
* Valve with a slotted stem (VG7xxxS) is required. Fluid temperature limit 120C.
VG8000N Series
DN15-150, PN16 Flanged Valves
2-WAY (PDTC - Normally Open), 3-WAY MIXING AND 3-WAY DIVERTING CONFIGURATIONS
Actuator Codes FA-2000-741x FA-2000-751x FA-3300 RA-3100-8226 VA-1x20** VA-1125** VA-78xx
Torque 150N 2200N 6000N 2700N 2000N 2500N 1000N
Valve Body Size Kvs Close-off Pressure (kPa)
DN15 0.1 / 0.16 / 0.25 - - - - - 1600 1600
0.4 / 0.63 / 1.0
1.6 / 2.5 / 4.0
DN20 4.0 / 6.3
DN25 6.3 / 10 1570
DN32 10 / 16 770
DN40 16 / 25 440
DN50 40 1030 650 800 1080
-
DN65 53 790 500 630 830
DN80 100 370 220 380 390
DN100 160 190
-
740 120 160 230
DN125 250 110 460
-
90 140
DN150 350 50 280 40 75
Notes: FA-2000 / 3000 heavy duty actuators are available on request if a higher close-off is required.
** For fluid temperature >140C the extension kit VA1000-EP must be fitted.
VG8000V Series
DN15-150, PN16 Flanged Valves
2-WAY (PDTC - Normally Open) AND 3-WAY MIXING CONFIGURATIONS
Actuator Codes FA-3300-741x RA-3000-732x VA-1x20** VA-1125** VA-78xx
Torque 6000N 3000N 2000N 2500N 1000N
Valve Body Size Kvs Close-off Pressure (kPa)
DN15 0.25 / 4.0 - - 1600 1600 1600
DN20 6.3
DN25 10 1570
DN32 16 770
DN40 25 440
DN50 40 1350 800 1080
-
DN65 63 1050 630 830
DN80 100 500 380 390
DN100 160 740 310 160 230
DN125 250 460 190 90 140
DN150 350 280 110 40 75
Note: FA-2000 / 3000 heavy duty actuators are available on request if a higher close-off is required.
** For fluid temperature >140C the extension kit VA1000-EP must be fitted.
STAINLESS STEEL TRIM VALVES - 2-way & 3-way Mixing Configurations
Actuator Codes VA-77xx VA-78xx
Torque 500N 1000N
Valve Body Size Kvs Close-off Pressure (kPa)
DN15 0.25 / 0.4
1600
1600 0.63 / 1.0 / 1.6
2.5 / 4.0 930
DN20 6.3 595 1220
DN25 10 370 770
DN32 16 230 470
DN40 25 145 300
DN50 40 90 190
45
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
Opening an Account
Johnson Controls products are available from a nationwide network of
wholesalers and distributors.
Should you wish to establish a trading account or require a list of your
nearest stockists please contact the Customer Support Team. You can
also email your request to products.uk@jci.com.
Placing an Order
Please help us to help you! So that we can process your
purchase orders quickly can you please ensure your purchase orders
show the correct part number and pricing. This will help us eradicate any
unwanted shipments, returns, delays and credits. If youre unsure of any
detail, please call the Customer Service Team in Slough for assistance.
Please send your order by fax to 0870 889 5664 or by post to our Slough
office: Johnson Controls Limited, Products Dept., 72 Buckingham Avenue,
Slough, Berkshire SL1 4PN
Minimum Order Value
Orders of less than 100 in value will be subject to a carriage charge
(packing and postage). Order values of over 100 include free delivery
within the United Kingdom.
Cancellation of Order
In the event of an order being cancelled then the customer is
liable for any costs incurred by Johnson Controls Limited. No cancellation
fee will be charged if the office is notified by writing within 24 hours of
placing the order. After that time a 15% re-stocking charge will apply. Non
standard items or customised products will be subject to different terms.
Product Warranty
3 years on all products
The warranty becomes invalid if the product has been tampered with in
any way or has been installed incorrectly or has been selected for an
unsuitable application.
Warranty Return
All warranty returns should be authorised prior to return by our Customer
Service Team (CST) in Slough. Full details are shown in the General
Conditions of Sale.
In short the process is:
1. Fill-out a return material authorisation (RMA) form on the next page and
fax/post to our Slough office.
2. Contact CST for an authorisation number and arrangement of the return
of the goods.
3. The goods are returned to Slough for checking ahead of returning to
their factory of origin for full inspection.
4. Credits are issued once these checks are completed.
ISO 9001 Accreditation
Johnson Controls Limited operates a Quality Management System which
complies with the requirements of ISO 9001:2008 for the following scope:
Property, facilities and services management. Project management of
construction and building services.
Consultancy services related to property portfolios.
Complete building service and maintenance management, covering, M&E
service, HVAC service, chiller service, building automation and control
systems, fire and security service. This would also encompass, turn-key
plant and system retrofit/upgrade; energy solutions; environmental and
legislative compliance. Procurement, project management, installation and
commissioning of building automation (including fire and security), heating
ventilation, air-conditioning control systems and air-conditioning systems.
The supply, systems design and installation of computerised access control,
alarm monitoring, intruder, CTV, fire, perimeter protection, time and
attendance and control systems, and the
provision of Customer Training.
WEEE Compliance
Johnson Controls Limited complies with the Waste Electrical and Electronic
Equipment Regulations 2006, through the Budget Pack WEEE Compliance
Scheme Accreditation No. WEE/UP3838PL/SCH, for 2007.
Producer Registration No. WEE/GC0069TY
General Ordering Information
FS 23823
ISO 9001:2008
46
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
Return Material Authorisation Request
Your Company
Your Name
Your Reference (if any)
Your Email Address
Fax No.
JCI Order Number
Your Order Number
Reason For Return
1. Fault
Type of fault

Electrical

Leak

Mechanical

Physical
Details of fault (please be specific)
2. Incorrectly Specified By Johnson Controls
Who specified (person)
Detail of specification
Why product does not
match specification
3. Wrong Part Supplied
Part Number Ordered
Part Number Supplied
4. Duplicated Order
Details of duplication
5. Part Number(s) being returned
Additional Comments
Johnson Controls Use Only
RMA Number
Issued By
Date
Please complete this form and fax to 0870 889 5664. The RMA Approval Number will then be faxed back to you.
Returns Address Johnson Controls, Products Dept. (Returns). 71/72 Buckingham Ave, Slough Industrial Estate, Slough, Berkshire SL1 4PN
47
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
General Conditions of Sale
1. Definitions
In these conditions
Seller means Johnson Controls Limited.
Buyer means any purchaser of Goods (hereinafter defined) from
the Seller.
Goods means the items which are the subject of sales between
the Buyer and the Seller.
Order means any contract for the sale of Goods by the Seller
to the Buyer to which theseConditions apply.
Instalment Delivery means the delivery of part only of the Goods, which are
to be purchased pursuant to the order.
Purchase Price means the price (exclusive of VAT and other taxes if any)
payable by the Buyer to the Seller in respect of the Order.
The masculine gender shall include the feminine and
neuter genders and singular number shall include the
plural and vice-versa.
2. Application
(A) All quotations, offers and tenders are made and all Orders are subject to the
following conditions. Subject only to Condition 2(B) all other terms, Conditions
or warranties whatsoever excluded from any other Contract between Seller
and Buyer or any other variation thereof unless expressly accepted in writing
by a director or other authorised representative of the Seller.
(B) In the event of a conflict between these Conditions and the Sellers express
terms of any quotation or acknowledgement of Order then such express
terms shall prevail.
(C) If any statement or representation has been made to the Buyer by the
Seller, or its officers, employees or agents upon which the Buyer relies
(other than in document(s) enclosed with the Sellers quotation or
acknowledgement of Order), then the Buyer must set out that statement or
representation in a document to be attached to or endorsed on the Order
and in any such case the Seller may confirm, reject or clarify the point and
submit a new quotation, if appropriate. Under no circumstances shall the
Seller be responsible for, or be held liable in respect of, any statement
or representation relied upon by the Buyer (other than a fraudulent or
representation) which is not attached to or endorsed on the Order and
subsequently confirmed in writing by the Seller.
(D) Unless otherwise agreed in writing all trade terms shall be interpreted in
accordance with INCOTERMS current at the time the Order is accepted.
3. Quotations
(A) A quotation by the Seller does not constitute an offer and the Seller
reserves the right to withdraw or revise the same at any time prior to the
Sellers acceptance of the Buyers Order.
(B) Quotations, offers and tenders issued by the Seller are for the whole of
the Goods referred to in them and the Seller reserves the right to refuse
acceptance of any Order which relates to only part of the Goods forming
the subject of a quotation, offer or tender.
(C) Quotations shall be available for acceptance for a maximum period of 14
days from date of issue and may be withdrawn by the Seller at any time
prior to the Buyers acceptance by written or oral notice.
4. Prices
(A) Save as otherwise agreed the Purchase Price shall be that contained in
the Sellers net list prices current at the time of despatch. The Seller shall
have the right at any time prior to despatch to withdraw any discount from
its normal prices and/or to revise prices to take into account increases in
costs including (without limitation) costs of any goods materials carriage
packaging labour or overheads the increase or imposition of any tax duty or
other levy and any variation in exchange rates.
(B) The minimum Purchase Price for any order shall be 100 (one hundred
pounds) and the Seller shall be entitled to charge the Buyer 100 (one
hundred pounds) exclusive of VAT and any other ancillary charges in
relation to any order submitted by the Buyer for Goods to a value of less
than 100 (one hundred pounds) without giving credit for the difference
between 100 (one hundred pounds) and the value of the Goods ordered.
(C) Where the Seller delivers the Goods the Buyer shall be liable to the Seller
for carriage costs and demurrage costs incurred by the Seller in the event
of vehicles being unduly delayed at the designated point of delivery.
(D) Unless otherwise specified VAT and any other tax or duties payable by the
Buyer shall be added to the Purchase Price.
5. Payment
(A) Unless otherwise agreed by the Seller in writing and subject to satisfactory
trade references, payment shall be due and payable (30) days after the date
of invoice. The Seller shall be entitled to submit its invoice with its delivery
advice note or any time afterwards save that where delivery has been
postponed at the request of or by the default of the Buyer then the Seller
may submit its invoice at any time after the Goods are ready for delivery or
would have been ready in ordinary course but for the request or default on
the part of the Buyer.
(B) Failure to pay on the due date shall entitle the Seller to withhold further
despatches in respect of he Order as well as in respect of any other
contract for the purchase of Goods between the Seller and the Buyer and
to serve notice on the Buyer requiring immediate payment for all Goods
supplied by the Seller under this and all other Contracts with the Buyer
whether or not payment is otherwise due or invoiced.
(C) Any extension of credit allowed to the Buyer may be changed or withdrawn
at any time.
(D) Save as otherwise agreed in writing by the Seller interest shall be payable
on overdue accounts at the annual rate of two per cent above the Base
Rate from time to time of National Westminster Bank Limited such interest
to accrue daily and to run from the due date for payment of the Purchase
Price until receipt by the Seller of the full amount thereof as well before as
after any judgement or order.
(E) No disputes arising under the Contract nor delays beyond the reasonable
control of the Seller shall interfere with prompt payment in full by the
Buyer.
6. Delivery
(A) The Seller shall advise the Buyer of the scheduled date of despatch.
(B) Delivery dated mentioned in any quotation acknowledgement of order or
elsewhere as approximate only and not of any contractual effect and the
Seller shall not be under any liability to the Buyer in respect of any failure
to deliver on any particular date or dates unless hereof such requirement
has been brought to the attention of the Seller by the Buyer and the Seller
has agreed in writing thereto. Time for delivery is given as accurately as
possible but is not guaranteed. The Buyer shall have no right to damages
or to cancel the Contract for failure for any cause to meet any delivery
stated. The date of delivery shall in every case be dependent upon prompt
receipt of all necessary information, final instructions or approvals from the
Buyer. Any delays or alterations by the Buyer in design, specifications or
quantities required may result in delay in delivery.
(C) By agreement in writing between the Seller and the Buyer the Order
may be satisfied by Instalment Deliveries PROVIDED ALWAYS that each
instalment Delivery shall be deemed to be a separate contract subject
mutates mutants to these Conditions of Sale and the Seller may accordingly
submit an invoice to the Buyer in respect of each Instalment Delivery for
a proportional part of the Purchase Price. Failure by the Buyer to take
delivery of or to make payment in respect of any one or more instalments
of Goods delivered under the Contract shall entitle the Seller to treat the
Contract as repudiated by the Buyer either in whole or in part.
(D) Delivery shall be at the Buyers premises unless otherwise agreed in writing
by the Seller.
(E) If the Buyer refuses or fails to take delivery of Goods tendered in
accordance with the Order the Seller shall be entitled to immediate
payment in full for Goods so tendered. The Seller shall be entitled to store
at the risk of the Buyer any Goods of which the Buyer refuses or fails to
take delivery and the Buyer shall in addition to the Purchase Price pay all
costs of such storage and any additional costs incurred as a result of such
refusal or failure. The Seller shall be entitled upon the expiration of 3
months from the date of invoice of dispose of the Goods in such manner
as the Seller may determine. The Seller will endeavour to comply with
reasonable requests by the Buyer for postponement of delivery but shall
be under no obligation to do so. Where delivery is postponed, otherwise
than due to the default by the Seller, the Buyer shall pay all costs and
expenses, including a reasonable charge for storage and transportation so
occasioned, and payment for the Goods shall be made in accordance with
these Conditions.
7. Risk
(A) Risk shall pass to the Buyer so that the Buyer is responsible for all loss,
damage or deterioration of the Goods: -
(I) If the Seller delivers the Goods by its own transport, or in accordance with
48
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
a specific contractual obligation arranges transport for the Goods, at the
time when the Goods arrive at the designated place of delivery; or
(II) In all other circumstances, at the time when the Goods leave the premises
of the Seller.
(B) Where delivery of the Goods to the Buyer is to be effected at the Sellers
premises risk therein shall pass to the Buyer upon transfer of the Goods to
the Buyers carrier or 30 days from the Seller notifying the Buyer that the
Goods are available for collection whichever first occurs.
(C) The Seller and the Buyer shall each effect and maintain insurance cover
against the risk accepted by them under this condition.
8. Title
(A) Title to the Goods shall only pass to the Buyer upon the happening of any
one of the following events:-
(I) The Buyer has paid to the Seller all sums (including) any default interest
due from it to the Seller under this Contract and under all other contracts
between the Seller and the Buyer including (for the avoidance or doubt)
any sums due under contracts made after this Contract whether or not the
same are immediately payable and under all contracts between the Seller
and any associate or subsidiary company of the Buyer or any company
under the ultimate control of the same parent company as has ultimate
control of the Buyer; or
(II) When the Seller serves on the Buyer notice in writing specifying that title in
the Goods has passed.
(B) The Seller reserves the right to re-possess any Goods in respect of which
payment is overdue and thereafter to re-sell the same and for this purpose the
Buyer hereby grants an irrevocable right and licence to the Sellers servants and
agents to enter upon all of any of its premises with or without vehicles during
normal business hours. This right shall continue to subsist notwithstanding the
termination or cancellation of the order for any reason and is without prejudice
to any accrued rights of the Seller thereunder or otherwise.
(C) Until title to the Goods has passed to the Buyer pursuant to these
Conditions it shall possess the Goods as fiduciary agent and baliee of the
Seller. If the Seller so requires, the Buyer shall store the Goods separately
from other goods and shall ensure that they are clearly identifiable as
belongings to the Seller.
9. Cancellation
(A) Subject to paragraph (C) of this Condition an Order may be varied or cancelled
by the Buyer at any time prior to delivery (or in the event of Instalment
Deliveries at any time prior to the delivery of any particular instalment in
respect of that Instalment Delivery but not in respect of Instalment Deliveries
already completed) by notice in writing to the Seller upon condition that
the Buyer pays to the Seller compensation pursuant to paragraph (B) of
this Condition PROVIDED ALWAYS that no variation or cancellation shall be
effective until receipt of the said compensation by the Seller. `
(B) The compensation payable under paragraph (A) of this Condition shall be
such sum not exceeding 15% of the Purchase Price as is stipulated by the
Seller for loss and expense occasioned by the variation or cancellation
including but not limited to loss of profit, administrative and restocking
charges, the capital cost of maintaining stocks, storage and internal
transportation charges. The Seller shall notify the Buyer of the amount of
compensation within a reasonable time of receiving the notice of variation
or cancellation from the Buyer.
(C) Nothing in this condition shall affect the rights of the Seller where a
purported variation or cancellation amounts to a wrong repudiation of the
Order. Goods returned tot he Seller without the Sellers written consent
will under no circumstances be accepted for credit.
(D) All variations required by the Buyer and accepted by the Seller shall be agreed
in writing and the price, if not agreed prior to the manufacture or delivery
of the Goods shall be based on appropriate contracts prices (if any) plus
escalation in respect of inflation and increased costs of materials and labour.
10. Third Party Rights
(A) The Buyer shall indemnify the Seller and hold him indemnified against any
and all liabilities claims and costs incurred by or made against the Seller
as a direct or indirect result of the carrying out of any work required
to be done on or to the Goods in accordance with the requirements
or specifications of the Buyer involving any infringement or alleged
infringement of any third party.
(C) The Seller shall have no liability to the Buyer in the event of the Goods
infringement or being alleged to infringe the rights of any third party. In
the event that the Goods are or may be the subject of patent copyright
registered design trade mark or other rights of any third party the Seller shall
be obliged to transfer to the Buyer only such title as the Seller may have.
11. Specifications
(A) The Buyer assumes responsibility that the Goods are suitable for his
purpose.
(B) Unless expressly agreed in writing by the Seller all drawings, designs,
specifications and particulars of weights and dimensions submitted by the
Seller are approximate only and the Seller shall have no liability in respect
of any deviation therefrom. Any performance figures given by the Seller
are based upon the Sellers experience and are such as the Seller would
expect to obtain on test. The Seller accepts no liability for failure to obtain
any performance figures quoted by him unless expressly and specifically
guaranteed by the Seller in writing. In the event of a failure to achieve
such performance figures the Seller may at its option replace or repair
the Goods concerned. The Seller reserves the right to alter or change
dimensions or composition of the Goods supplied to conform to applicable
standards or laws or otherwise within reasonable limits having regard to
the nature of the Goods.
(C) The Seller accepts no responsibility for any error omissions or other defects
in any drawings, designs, or specifications not prepared by the Seller and
the Buyer against any and all liabilities and expenses incurred by the Seller
arising therefrom shall indemnify the Seller.
(D) All drawings designs or specifications supplied by the Seller under or in
connection with any quotation or contract of sale shall remain the property
of the Seller and the Buyer shall not copy them without the consent of the
Seller and shall comply with the Sellers reasonable requirements as to
their use, return and otherwise.
(E) The information contained in advertising, sales and technical literature issued
by the Seller may be relied upon to be accurate in the exact circumstances
in which it is expressed, otherwise any illustrations, performance details,
examples of installations and methods of assembly and all other technical
data in such literature are based on experience and upon trials under test
Conditions and are provided for general guidance only. No such information
or data shall form part of the Contract unless the Buyer shall have complied
with condition 2 (C) relating to statements and representations. All drawings,
documents, confidential records, computer software and other information
supplied by the Seller are supplied on the express understanding that
copyright is reserved to the Seller and that the Buyer will not, without the
written consent of the Seller, either give away, loan, exhibit or sell any such
drawings, documents, records, software or other information or extracts
therefrom or copies thereof or use them in any way except in connection
with the Goods in respect of which they are issued.
(F) All claims for alleged infringement in respect of patents, trade marks,
registered design, design right or copyright received by the Buyer must be
notified immediately to the Seller and the Seller must thereafter be kept
fully informed of the conduct of such claims.
(G) The Buyer shall be solely responsible for ensuring that all drawings,
information, advice and recommendations given to the Seller,
either directly or indirectly by the Buyer or by the Buyers officers,
employees, agents, consultants, or advisers, are accurate, correct and
suitable. Examination or consideration by the Seller of such drawings,
information, advice or recommendations shall in no way limit he Buyers
responsibility hereunder unless the Seller under the hand of a director or
other authorised representative specifically agrees in writing to accept
responsibility.
(H) The Buyer shall indemnify the Seller from and against all actions, claims,
costs, and proceedings which arise due to the manufacture of Gods or
performance of services to the drawings or specifications of the Buyer
where such drawings or specifications are at fault or where it is alleged that
they involve an infringement of patent, copyright, registered, design, design
right or design copyright or other exclusive right.
(I) The Seller can give no guarantee of the suitability of materials or design
Goods made specially to the Buyers requirements and differing from
Sellers standard specifications even if the purpose be known to the Seller.
(J) The Seller cannot accept responsibility for Buyers samples, drawings,
tools and the like while in he Sellers possession and the Seller will not
accept any claim for loss, breakages or damages to the same whatever the
cause. It is agreed between the Seller and the Buyer that the Buyer shall
General Conditions of Sale (cont)
49
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
be responsible for insurance cover in its own name and its cost for the risks
specified in this Condition 12.
(K) Where materials are supplied by the Buyer to the Seller such materials shall
remain at the risk of the Buyer at all times and the Seller shall not be liable
for the loss of, or damage to, any material during fabrication by the Seller
or by any sub-contractor employed by the Seller or whilst on premises of
the Seller or any such sub-contractor or in transit to or from the premises
to the Seller or of any sub-contractor provided that the Seller may, at its
own discretion, make a contribution towards the replacement costs of the
material.
(L) Where materials are supplied by, or on behalf of, the Buyer to the Seller
the Buyer shall be responsible to ensure that the material is of satisfactory
quality and is fit for its purpose and shall indemnify the Seller against any
loss, damage, injury or expense whatsoever arising directly from any fault
in incorrect specification of the said material.
12. Tests
(A) The Goods are carefully inspected and when practicable submitted to the
Sellers standard tests before despatch. The Seller shall make an extra
charge for any special tests requested by the Buyer. If the Buyer or his
appointed representative desires to be present at such tests and is given
reasonable notice of the date and time of the tests by the Seller but is not
present at the notified date and time the tests shall proceed and shall be
deemed to have been carried out in the manner described by the Buyer or
his appointed representative.
13. Liability
(A) The Seller hereby undertakes that for a period of twelve months from
and including the date of delivery he shall at no cost to the Buyer and at
the option of the Seller repair or replace any Goods found not to be of
merchantable quality due to defective workmanship or materials PROVIDED
ALWAYS that the Goods concerned are promptly returned carriage paid to
the Sellers premises.
(B) The Seller shall not be liable to the Buyer.
(B1) The Buyer shall have no claim for shortages or defects in the Goods
supplied apparent in visual inspection unless: -
(I) The Buyer inspects the Goods within (three) working days of their arrival at
its premises or other agreed destinations; and
(ii) a written complaint specifying the shortage or defect is made to the Seller
and to the carrier within (seven) working days of delivery in the event of
shortage, defect, or non-delivery of any separate part of a consignment, or
within (fourteen) working days of the notified date if despatch in the event
of non-delivery of a whole consignment or, in either event, within such
shorter period as the carriers Conditions (if applicable) require; and
(iii) the Seller is given an opportunity to inspect the Goods and investigate any
complaint before any use of or alteration to or interference with the Goods.
(B2) The Buyer shall have no claim in respect of defects in the Goods supplied
and services performed which are not apparent on visual inspection at the
time of delivery or completion of performances unless.
(i) a written complaint is sent to the Seller as soon as reasonably practicable
after the defect is discovered and no use is made of the Goods thereafter
and no alteration made thereto or interference made therewith before the
Seller is given an opportunity to inspect the Goods (and service performed)
in accordance with this Condition, and
(II) the complaint is sent within (12) months of the date of delivery of the
Goods or completion of the performance of the services or, in the case
of an item not manufactured by the Seller, within the guarantee period
specified by the manufacturer of such items.
(C) In the case of Goods not manufactured by the Seller the Buyer shall be
entitled only to such warranties or guarantees as are available tot he Seller
in respect thereof.
(D) The Seller may at its option make good any shortage or non delivery
and/or as appropriate replace or repair any Goods found to be damaged
or defective PROVIDED ALWAYS that the damaged or defective Goods are
promptly returned carriage paid to the Sellers premises.
(E) The Sellers aggregate liability to the Buyer whether for negligence breach
of contract misrepresentation or otherwise shall in no circumstances
exceed the cost of the defective, damaged or undelivered Goods
determined by net price invoiced to the Buyer In respect of any occurrence
of series of occurrence.
(F) The Sellers prices are determined on the basis of the limits of liability set
out in this Condition. The Buyer may by written notice to the Seller request
to agree a higher limit of liability set out in this Condition. The Buyer may
by written notice tot he Seller request the Seller to agree a higher limit of
liability provided insurance cover can be obtained therefor. The Seller shall
effect insurance up to such limit and the Buyer shall pay upon demand the
amount of any and all premiums. The Buyer shall disclose such information,
as the insurers shall require. In no case shall the Buyer be entitled to
recover from the Seller more than the amount received from the insures.
(G) Subject to the foregoing all conditions warranties and representatives
expressed or implies by statute common law or otherwise in relation to
the Goods are hereby and excluded and the Seller shall be under on liable
to the Buyer for any loss damage or injury direct resulting from defective
material faulty workmanship or otherwise however arising and whether or
not caused by the negligence of the Seller its employees or agents SAW
the Seller shall accept liability for death or personal injury caused by them
negligence of the Seller.
(H) If a complaint is not made to the Seller as provided in this Condition 13
then the Goods shall be deemed to be in all respect in accordance with the
Contract and the Buyer shall be bound to pay for the same accordingly.
(I) Defects in quality or dimension in any instalment delivery shall not be a
ground for cancellation of the remainder of the Contract.
(J) The Buyer shall not be entitled to any claim in respect of any repairs or
alterations undertaken by the Buyer without prior specific written consent
of the Seller nor in respect of any defect arising by reason of fair wear and
tear or damage due to accident, neglect or misuse nor in respect of any
Goods to which alterations have been made without such consent or to
which replacement parts not supplied by the Seller have been fitted.
(K) The Seller shall not be liable for (and the Buyer shall indemnify the Seller
against claims arising therefrom) loss or damage suffered by reason of
use of the Goods after the Buyer becomes aware of a defect or after
circumstances which should reasonably have indicated to the Buyer the
existence of a defect.
(L) The Seller may within 15 days of receiving a written complaint (or 28
days where the Goods are suitable outside the United Kingdom) inspect
the Goods and the Buyer, if so required by the Seller, shall take all steps
necessary to enable the Seller to do so.
(M) Save as otherwise provided by the other Conditions of these Selections 13 to
15 if the Sale of Goods Act 1979 and, where applicable, Sections 3 to 5 of the
Supply of Goods and Services Act 1982 are to be implied into the Contract.
(N) In the event of the condition of the Goods or the performance of the
services being such as might or would (subject to these Conditions) entitle
the Buyer to claim damages, to repudiate the Contract and/or reject the
Goods or services the Buyer shall not then do so but shall first ask the
Seller to repair or supply satisfactory substitute Goods (or rectify the
services) and the Seller shall thereupon be entitled at its option to repair or
take back the defective Goods and to supply satisfactory substitute Goods
or perform works of rectification free of cost and within a reasonable time
or to repay the price of the Goods and/or services in respect of which the
complaint is made.
(O) If the Seller does so repair the Goods or supply satisfactory Goods or effect
repayment or rectification pursuant to Condition (N) above the Buyer shall
be bound to accept such repaired or substituted Goods, repayment or
rectification and the Seller shall be under no liability in respect of any loss
or damage whatsoever arising from the initial delivery of the defective
Goods or from the initial performance of the services or from the delay
before the defective Goods are repaired or the substitute Goods are
delivered or the repayment or rectification is effected.
(P) In the case of Goods not manufactured by the Seller:-
(I) the Seller gives no assurance or guarantee whatsoever that the sale or
use of the Goods will not infringe the patent, copyright or other industrial
property rights of any other person, firm of company, and
(II) the guarantee will be limited to the guarantee (if any) which the Seller
receives from the manufacturer or supplier of such Goods.
(Q) The Seller shall not be liable:-
(I) in respect of claims arising by reason of death or personal injury unless
the Seller is shown to have failed to exercise reasonable care in the
performance of the Contract and/or the Goods are deemed to be defective
within the meaning of Part 1 of the Consumer Protection Act 1987, or
50
Sales and Technical Support - 01753 870300
fax: 0870 889 5664, email: products.uk@jci.com
(III) in respect of claims arising through damage to property unless the Goods
are deemed to be defective within meaning of Part 1 of the Consumer
Protection Act 1987.
(R) Further, under no circumstances whatsoever shall the Seller be liable for
consequential loss (including removal of rectification of work required in
connection with the installation of repaired or substitute Goods) loss of
profits, damage to property or wasted expenditure.
(S) Without prejudice to Condition (R) where Goods are supplied for the
purpose of a business the Sellers liability, whether in respect of one claim
or the aggregate of various claims (other than claims for death or personal
injury or pursuant to Part 1 of the Consumer Protection Act 1987), shall not
exceed [100,000] and the Buyer agreed to insure adequately to cover
claims in excess of such amount.
14. Licences and Consents
(A) If any licence or consent of any government or other authority shall be
required for acquisition carriage or use of the Goods by the Buyer the Buyer
shall obtain the same at its own expense and if necessary produce evidence
of the same to the Seller on demand. Failure to do so shall not entitle the
Buyer to withhold or delay payment of the Purchase Price. Any additional
expense or charges incurred by the Sellers resulting from such failure shall
be for the Buyers account.
15. Force Majeure
(A) The Seller shall not be liable to the Buyer for any loss or damage which
may be suffered by the Buyer as a direct or indirect result of the supply
of Goods by the Seller being prevented hindered delayed or rendered
uneconomic by reason of circumstances or events beyond the Sellers
reasonable control including but not limited to Acts of God war riot strike
lock-out trade dispute or labour disturbance accident break-down of plant
or machinery fire flood storm difficulty or increased expense in obtaining
workmen materials or transport or other circumstances affecting the supply
of the Goods or of raw materials therefor by the Sellers normal source of
supply or the manufacture of the Goods by the Sellers normal means or
the delivery of the Goods by the Sellers normal route or means of delivery.
The Seller may at its option suspend performance or cancel its obligations
under the Contract without liability for any damage or consequential
loss resulting therefrom such suspension or cancellation being without
prejudice to the Sellers right to recover all sums owing to it in respect of
consignments delivered, and/or services performed, and costs incurred
prior to the date of suspension or cancellation.
16. Insolvency Default
(A) If the Buyer ceases to trade or enters into a deed of arrangement or
commits an act of bankruptcy or compounds with his creditors or if a
receiving order is made against him or if (being a company) an order is
made or a resolution is passed for the winding up of the Buyer (otherwise
than for the purposes of amalgamation or reconstruction) or if a receiver is
appointed of any of the Buyers assets or undertaking or if circumstances
arise which entitle the court or a creditor to appoint a receiver or a
manager or which entitles the Court to make a winding up order or if the
Buyer takes or suffers any similar or analogous action in consequence of
debt or commits any breach of this or any other contract between the
Seller and the Buyer the Seller may without prejudice to any of its other
rights stop any Goods in transit and/or suspend further deliveries and/or
determine the rights of the Buyer under condition 8 hereof and/or by notice
in writing to the Buyer determine the contract.
17. Waiver
(A) Failure by the Seller to exercise or enforce any rights hereunder shall no
be deemed to be a waiver of any such right nor operate so as to bar the
exercise or enforcement thereof at any time or times thereafter.
18. Notices
(A) Any notice hereunder shall be deemed to have been duly given if sent by
prepaid first class post or telex to the party concerned at his last known
address. Notices sent by first call post shall be deemed to have been given
seven days after despatch and notices sent by telex shall be deemed to
have been given on the date of despatch.
19. Clause Headings
(A) Clause headings are inserted in these Conditions for ease of reference
only and do not form part of the contract for Sale for the purpose of
interpretation.
20. Governing Law
(A) The contract shall be governess by and construed in accordance with the
laws of England and the parties hereby submit to the jurisdiction of the
English Courts.
21. Consumer Protection Act 1987 (the Act)
(A) In circumstances where the Seller supplies parts or products to the Buyer
for incorporation with, or use ancillary to, any composite or other products
to be produced, manufactured, processed or supplied by the Buyer then:-
(i) the Buyer shall forthwith on demand produce for inspection by the
Seller copies of all written instructions, information and warnings to be
supplied by the Buyer in relation to the said composite or other products,
provided nevertheless that such inspection or right to inspect shall not
itself constitute acceptance or approval on the part of the Seller of such
instructions, information or warnings, and
(ii) the Buyer shall indemnify, reimburse and compensate the Seller for all
losses and damages (including costs, expenses and charges for legal
actions in which the Seller may be involved) that the Seller may incur, or
has to bear, in the event that any claim or claims are made against the
Seller pursuant to the Act or otherwise relating to the said composite
or other products of the Buyer in circumstances in which the part or
product supplied by the Seller was either (I) not the defective part of the
said composite product, or (ii) was only rendered the defective part or
became a defective product by reason of actions or omissions of the Buyer
(including without limitation the supply of defective free issue materials),
or (iii) was only rendered he defective part or become a defective product
by reason of instructions or warnings given by the Buyer or other supplier
of said composite or other products or (iv) supplied in accordance with a
specification and/or drawing furnished by, or on behalf of, the Buyer.
(iii) for the purposes of this Condition only the world defective shall be
interpreted in accordance with the definition of defect contained in Part 1
of the Act.
(B) The Buyer hereby acknowledges that it is under a duty to pass on to its
customers (where appropriate) all instructions, information and warnings
supplied to it by the Seller with the Goods.
22. Assignment
(A) The Contract is between the Seller and the Buyer as principles and under
no circumstances shall the Buyer assign the benefit or burden of it without
the prior written consent of the Seller. The Seller shall be entitled to assign
or sub-contract the whole or part of its obligations under the Contract.
23. Severability
(A) In the event of any provision of these Conditions being or becoming void in
whole or in part the other provisions of these Conditions shall remainfully
valid and enforceable and void provisions shall, where appropriate, be
replaced in accordance with the meaning and purpose of these Conditions.
24. Attendance on Site
(A) Should the Seller attend on the Buyers premises to perform any services in
relation to the Contract then the Buyer shall indemnify the Seller in respect
of all claims made, or proceedings taken, against the Seller (and associated
legal costs) by any third party including but not limited to the Sellers
employees, the Buyers employees or the employees of any contractor
employed by the Buyer or the personal representatives or dependants of
such employees or other third parties in respect of death, personal injury
or damage to property (including damage as a result of fire or explosion)
caused by or arising out of the work in any manner whatsoever.
25. Packing
(A) Unless otherwise agreed in writing, cases and other packing materials,
when charged for, will be credited if returned to the Sellers works within
[14 days] of the date of invoice, carriage paid and in good Condition.
(B) Any packaging supplied by the Seller, unless otherwise expressly agreed in
writing, is intended to provide adequate protection in normal Conditions of
transit of usual duration.
General Conditions of Sale (cont)
51
Field Sales - UK South - Graham Vail 0777 980 8349
UK North - Peter OMalley 0777 980 8348
OEM Sales - Kevin Kirby 0777 980 8525
For further information and additional models
please refer to the product data sheet.
You will find our industry leading tool for valve sizing and selection
HIPPOS on this CD, with instructions on how to install the program.
We have also included data sheets for our full range of products. If you
require further information please contact the Sales Support Team.
Valve Sizing Software and Product Data Sheets
Johnson Controls Limited
UK Products Group
72 Buckingham Avenue
Slough
Berkshire SL1 4PN
United Kingdom
Tel: 01753 870300
Fax: 0870 889 5664
Email: products.uk@jci.com
Web: www.johnsoncontrols.com
Your stockist:
Johnson Controls Limited, a company registered in England & Wales.
Registered office: Johnson Controls Limited, 2 The Briars, Waterberry Drive,
Waterlooville, Hants, PO7 7YH, United Kingdom. Registered number: 661449.
2009-2010 Johnson Controls Limited. All rights reserved. Printed in England
Manufacturer reserves the right to change specifications without prior notice. E & OE

You might also like