Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
42 views

Ayoko Nga Scroll Down Beh

This document contains 3 questions and solutions regarding flow measurement devices: 1) Rotameters operate based on variable area principle where a float raises in a tapered tube based on fluid flow. They are more accurate and reliable than other flowmeters while also having low cost and head loss. 2) Given parameters of a Venturi meter, the volume flow rate of water is calculated to be 2.349 x 10-3 m3/s and average velocity is 1.196 m/s. 3) Given parameters of a flow nozzle, the volume flow rate is 0.00172 m3/s, average velocity is 2.43 m/s, and head loss is 0.306m.

Uploaded by

YanYan Carpio
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views

Ayoko Nga Scroll Down Beh

This document contains 3 questions and solutions regarding flow measurement devices: 1) Rotameters operate based on variable area principle where a float raises in a tapered tube based on fluid flow. They are more accurate and reliable than other flowmeters while also having low cost and head loss. 2) Given parameters of a Venturi meter, the volume flow rate of water is calculated to be 2.349 x 10-3 m3/s and average velocity is 1.196 m/s. 3) Given parameters of a flow nozzle, the volume flow rate is 0.00172 m3/s, average velocity is 2.43 m/s, and head loss is 0.306m.

Uploaded by

YanYan Carpio
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

AYOKO NGA

Scroll down beh

JOKE TIME PARIN TO


HAHAHAHAHA

PINAGHIRAPAN KO TO
TAS IKAW LANG
MAKIKINABANG? PWE.

JK LABYU ETO NA
TALAGA.

1. What is the operating principle of variable-area flowmeters (rotameters)? How do they


compare to other types of flowmeters with respect to cost, head loss, and reliability?
In rotameters, there are five primary elements: The metering tube, float, scale, Process
connections (end fittings), and Body/Housing. Its operation is based on the variable area
principle where the flow raises a float in a tapered tube, which increases the area for passage
of the fluid flow. When the gravitational force equals the force exerted by the flowing fluid
and buoyance, the float is in a stable position. The rotameter has a higher accuracy than
other flowmeters, so it is more reliable. It is a well-known cost effective solution for flow
measurement of liquids and gases. The pressure drop across the float is low and remains
essentially constant so the head loss is lower as compared to other flowmeters.
2. A Venturi meter equipped with a differential pressure gage is used to measure the flow
rate of water at 15C (=999.1 kg/m3) through a 5-cm-diameter horizontal pipe. The
diameter of the Venturi neck is 3 cm, and the measured pressure drop is 5 kPa. Taking the
discharge coefficient to be 0.98, determine the volume flow rate of water and the average
velocity through the pipe.
GIVEN:
=999.1 kg/m3
d= 5cm = 0.05m
T= 15 C = 288.15K
Dv= 3 cm = 0.03m
P1-P2= 5 kPa
REQD: Vave
SOLN:

2(P 1P 2)
Cv

1 4

V=

Cv = 0.98
= 0.003/0.005 = 0.6
P1-P2 = 5000 Pa
V = 3.323 m/s

Q = VA = (3.323)( 4

Vave =

)(0.03)2 = 2.349 x10-3 m3/s

2.349 x 103 m3 /s

( 0.05 ) 2
4

()

= 1.196 m/s

3. A flow nozzle equipped with a differential pressure gage is used to measure the flow rate
of water at 10C ( =999.7 kg/m3 and =1.307 x 10-3 kg/m s) through a 3-cm-diameter
horizontal pipe. The nozzle exit diameter is 1.5 cm, and the measured pressure drop is 3
kPa. Determine the volume flow rate of water, the average velocity through the pipe, and
the head loss.

1.5
0.5
3.0

Q AoCd

2(3000)
2 P

(0.03) 2 x0.96 x
4
(1 ) 4
999.7(1 0.5 4 )
= 0.00172

Q 0.00172m 3 / s

A
/ 4(0.03) 2

hL
= 2.43 m/s

m3 / s

P
3000

g 999.7(9.81)

= 0.306m